Users Guide

In the Default VLAN, you cannot use the no untagged interface command. To remove an untagged
interface from all VLANs, including the Default VLAN, enter INTERFACE mode and use the no
switchport
command.
Related
Commands
interface vlan — configure a VLAN.
tagged — specify which interfaces in a VLAN are tagged.
Far-End Failure Detection (FEFD)
The Dell Networking operating software supports far-end failure detection (FEFD) on the Ethernet interfaces of the S4820T
platform.
The FEFD feature detects and reports far-end link failures.
FEFD is not supported on the Management interface.
During an RPM failover, FEFD is operationally disabled for approximately 8 to 10 seconds.
By default, FEFD is disabled.
debug fefd
Enable debugging of FEFD.
Syntax
debug fefd {events | packets} [interface]
To disable debugging of FEFD, use the no debug fefd {events | packets} [interface]
command.
Parameters
events Enter the keyword events to enable debugging of FEFD state changes.
packets Enter the keyword packets to enable debugging of FEFD to view information on
packets sent and received.
interface (OPTIONAL) Enter the following keywords and the interface information:
For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet
then the slot/port information.
For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the
slot/port information.
Command Modes EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
Networking OS Command Line Reference Guide.
Version Description
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
Layer 2 997