Concept Guide

Example of the show cam-usage Command
DellEMC#show cam-usage
Stackunit|Portpipe| CAM Partition | Total CAM | Used CAM |Available CAM
========|========|=================|=============|=============|==============
0 0 | IN-L3 ACL | 512 | 1 | 511
| | IN-V6 ACL | 0 | 0 | 0
| | IN-L2 ACL | 768 | 0 | 768
| | OUT-L3 ACL | 158 | 5 | 153
| | IN-L3 ECMP GRP| 1024 | 0 | 1024
| | OUT-V6 ACL | 158 | 0 | 158
| | OUT-L2 ACL | 206 | 7 | 199
7 | 0 | IN-L3 ACL | 512 | 1 | 511
| | IN-V6 ACL | 0 | 0 | 0
| | IN-L2 ACL | 768 | 0 | 768
| | OUT-L3 ACL | 158 | 5 | 153
| | OUT-V6 ACL | 158 | 0 | 158
| | OUT-L2 ACL | 206 | 7 | 199
Codes: * - cam usage is above 90%.
DellEMC#
Conguring CAM Threshold and Silence Period
This section describes how to congure CAM threshold and silence period between CAM threshold syslog warnings.
The CAM threshold and silence period conguration is applicable only for Ingress L2, IPv4, IPv6 and Egress L2, IPv4, and IPv6 ACL CAM
groups. For other ACL CAM regions, the CAM threshold and silence period is xed and the values are 90 percent and 0 respectively.
You can assign CAM threshold value using cam-threshold command to receive syslog messages when the CAM usage reaches the
congured CAM threshold. The congured CAM threshold is a value specic to FP based on CAM features such as Ingress and Egress L2,
IPV4, IPV6. The system checks the CAM usage of the features with the set threshold to display a syslog message, which contains the
CAM region, slot/port-pipe and pipeline information. By default, syslog warning appears when the CAM usage is 90 percent.
You can also congure the silence period for the syslog message on the CAM usage. A syslog warning appears when the CAM usage
exceeds the congured CAM threshold. The silence period starts after the initial syslog warning. The syslog warning does not appear until
the silence period is active. By default, the silence period is 0 seconds.
Setting CAM Threshold and Silence Period
To congure the CAM threshold and silence period, use the following commands.
Assign the CAM threshold percentage
CONFIGURATION mode
cam-threshold threshold {default | threshold-percent}
The range of threshold value is from 1 to 100. The default threshold value is 90 percent.
Assign the silence period for syslog warning.
CONFIGURATION mode
cam-threshold threshold {default | threshold-percent} silence-period {default | silence-
period-value}
The range of silence period is from 0 to 65535. The default is 0 seconds.
NOTE
:
If you delete a FP in a CAM region that is assigned with threshold, a syslog warning appears even during the silence period.
The system triggers syslog during the following events:
242
Content Addressable Memory (CAM)