Dell Command Line Reference Guide for the S4820T System 9.8(0.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright, 2009 – 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 About this Guide.............................................................................................................41 Objectives......................................................................................................................................................................... 41 Audience...........................................................................................................................................................................
Control and Monitoring..................................................................................................87 asf-mode.......................................................................................................................................................................... 87 banner exec......................................................................................................................................................................88 banner login.............
show login statistics........................................................................................................................................................130 show memory................................................................................................................................................................. 132 show processes cpu............................................................................................................................................
dot1x auth-server............................................................................................................................................................ 174 dot1x auth-type mab-only............................................................................................................................................... 175 dot1x authentication (Configuration)..............................................................................................................................
resequence prefix-list ipv4........................................................................................................................................222 seq........................................................................................................................................................................... 223 Common MAC Access List Commands..........................................................................................................................
set local-preference................................................................................................................................................. 264 set metric.................................................................................................................................................................264 set metric-type........................................................................................................................................................
deny (for IPv6 ACLs)....................................................................................................................................................... 311 8 Access Control List (ACL) VLAN Groups and Content Addressable Memory (CAM).... 314 member vlan................................................................................................................................................................... 314 ip access-group........................................................
bgp dampening........................................................................................................................................................ 350 bgp default local-preference..................................................................................................................................... 351 bgp dmzlink-bw........................................................................................................................................................
neighbor route-reflector-client.................................................................................................................................. 391 neighbor send-community........................................................................................................................................392 neighbor shutdown..................................................................................................................................................
show ip extcommunity-list........................................................................................................................................447 IPv6 BGP Commands.....................................................................................................................................................447 clear ip bgp ipv6 unicast soft....................................................................................................................................
priority-group........................................................................................................................................................... 480 qos-policy-output ets................................................................................................................................................481 set-pgid.................................................................................................................................................................
hardware watchdog.................................................................................................................................................. 517 show hardware layer2............................................................................................................................................... 517 show hardware layer3...............................................................................................................................................
ip dhcp snooping database renew............................................................................................................................ 558 ipv6 dhcp snooping database renew........................................................................................................................ 558 ip dhcp snooping trust............................................................................................................................................. 559 ipv6 dhcp snooping trust..
fip-snooping port-mode fcf............................................................................................................................................590 fip-snooping port-mode fcoe-trusted............................................................................................................................. 591 show fip-snooping config................................................................................................................................................
show patch.................................................................................................................................................................... 628 show processes restartable............................................................................................................................................628 show redundancy....................................................................................................................................................
interface range..........................................................................................................................................................671 interface range macro (define)................................................................................................................................. 674 interface range macro name.....................................................................................................................................
show interfaces port-channel................................................................................................................................... 724 show port-channel-flow........................................................................................................................................... 727 Time Domain Reflectometer (TDR)................................................................................................................................ 729 tdr-cable-test....
ip host............................................................................................................................................................................ 764 ip icmp source-interface.................................................................................................................................................765 ipv6 icmp source-interface.................................................................................................................................
clear ipv6 route.............................................................................................................................................................. 822 clear ipv6 mld_host........................................................................................................................................................822 maximum dynamic-routes-ipv6...................................................................................................................................
debug isis local-updates................................................................................................................................................. 860 debug isis snp-packets....................................................................................................................................................861 debug isis spf-triggers.............................................................................................................................................
redistribute bgp.............................................................................................................................................................. 897 redistribute ospf.............................................................................................................................................................898 router isis................................................................................................................................................
show vlan..................................................................................................................................................................941 tagged......................................................................................................................................................................944 track ip.........................................................................................................................................................
arp (for Multicast MAC Address)................................................................................................................................... 978 mac-address-table static (for Multicast MAC Address)..................................................................................................979 ip vlan-flooding..............................................................................................................................................................
ip multicast-limit...................................................................................................................................................... 1014 ip multicast-routing................................................................................................................................................. 1015 show ip mroute........................................................................................................................................................
track resolution ipv6 route...................................................................................................................................... 1049 40 Open Shortest Path First (OSPFv2 and OSPFv3).................................................... 1051 OSPFv2 Commands......................................................................................................................................................1051 area default-cost....................................................
show ip ospf........................................................................................................................................................... 1088 show ip ospf asbr................................................................................................................................................... 1090 show ip ospf database.............................................................................................................................................
show crypto ipsec policy.......................................................................................................................................... 1141 show crypto ipsec sa ipv6....................................................................................................................................... 1143 show ipv6 ospf database.........................................................................................................................................
show ip pim tib........................................................................................................................................................ 1185 show running-config pim......................................................................................................................................... 1187 43 Port Monitoring........................................................................................................ 1189 description.................................
description.............................................................................................................................................................. 1227 match ip access-group........................................................................................................................................... 1228 match ip dscp.........................................................................................................................................................
default-information originate.........................................................................................................................................1264 default-metric...............................................................................................................................................................1265 description........................................................................................................................................................
hello-time..................................................................................................................................................................... 1306 max-age........................................................................................................................................................................1307 protocol spanning-tree rstp............................................................................................................................
radius-server host...................................................................................................................................................1344 radius-server key.................................................................................................................................................... 1346 radius-server retransmit..........................................................................................................................................
ip ssh server............................................................................................................................................................1378 ip ssh server vrf......................................................................................................................................................1380 show crypto...........................................................................................................................................................
SNMP Commands.........................................................................................................................................................1414 show snmp.............................................................................................................................................................. 1414 show snmp engineID...............................................................................................................................................
56 Stacking.................................................................................................................. 1460 redundancy disable-auto-reboot................................................................................................................................... 1460 redundancy force-failover stack-unit............................................................................................................................. 1461 redundancy protocol............................
ntp disable.................................................................................................................................................................... 1499 ntp multicast client....................................................................................................................................................... 1499 ntp master ......................................................................................................................................
member........................................................................................................................................................................ 1532 stack-unit stack-group..................................................................................................................................................1533 vlan-stack access..............................................................................................................................................
description.................................................................................................................................................................... 1567 ip vrf forwarding........................................................................................................................................................... 1568 ip route-export..........................................................................................................................................
1 About this Guide This book provides information about the Dell Networking OS command line interface (CLI). This book also includes information about the protocols and features found in Dell Networking OS.
Information Icons This book uses the following information symbols: NOTE: The Note icon signals important operational information. CAUTION: The Caution icon signals information about situations that could result in equipment damage or loss of data. WARNING: The Warning icon signals information about hardware handling that could result in injury.
2 CLI Basics This chapter describes the command line interface (CLI) structure and command modes. The Dell Networking operating software commands are in a text-based interface that allows you to use the launch commands, change command modes, and configure interfaces and protocols. Accessing the Command Line When the system boots successfully, you are positioned on the command line in EXEC mode and not prompted to log in. You can access the commands through a serial console port or a Telnet session.
In this case, the user is “admin” on vty2. Obtaining Help As soon as you are in a command mode there are several ways to access help. To obtain a list of keywords at any command mode: Type a ? at the prompt or after a keyword. There must always be a space before the ?. To obtain a list of keywords with a brief functional description: Type help at the prompt. To obtain a list of available options: Type a keyword and then type a space and a ?.
• To navigate left or right in the Dell Networking OS command line, use the left and right Arrow keys. The shortcut key combinations at the Dell Networking OS command line are as follows: Key Combination Action CNTL-A Moves the cursor to the beginning of the command line. CNTL-B Moves the cursor back one character. CNTL-D Deletes the character at the cursor. CNTL-E Moves the cursor to the end of the line. CNTL-F Moves the cursor forward one character. CNTL-I Completes a keyword.
Using the Keyword no Command To disable, delete or return to default values, use the no form of the commands. For most commands, if you type the keyword no in front of the command, you disable that command or delete it from the running configuration. In this guide, the no form of the command is described in the Syntax portion of the command description.
Enabling Software Features on Devices Using a Command Option This capability to activate software applications or components on a device using a command is supported on the S4810, S4820T, and S6000, platforms. Starting with Release 9.4(0.0), you can enable or disable specific software functionalities or applications that need to run on a device by using a command attribute in the CLI interface.
show feature Verify the status of software applications, such as VRF, that are activated and running on a device. S4820T Syntax show feature Command Modes EXEC EXEC Privilege Command History Version 9.4(0.0) Introduced on the S4810, S4820T, and S6000. Usage Information You can activate VRF application on a device by using the feature vrf command in CONFIGURATION mode. The no feature vrf command is not supported on any of the platforms.
CONFIGURATION Mode In EXEC Privilege mode, use the configure command to enter CONFIGURATION mode and configure routing protocols and access interfaces. To enter CONFIGURATION mode: 1. Verify that you are logged in to EXEC Privilege mode. 2. Enter the configure command. The prompt changes to include (conf). From this mode, you can enter INTERFACE mode by using the interface command. CONTROL-PLANE Mode To manage control-plane traffic, use CONTROL-PLANE mode.
ECMP GROUP Mode To enable or configure traffic distribution monitoring on an ECMP link bundle, use ECMP GROUP mode. For more information, refer to ecmp_overview. To enter ECMP GROUP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the ecmp-group command then enter the ECMP group ID. The prompt changes to include (conf-ecmp-group-ecmpgroup-id). You can return to CONFIGURATION mode by using the exit command.
To enter FRRP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the protocol frrp command then the ring ID. The prompt changes to include (conf-frrp-ring-id). You can return to CONFIGURATION mode by using the exit command. INTERFACE Mode Use INTERFACE mode to configure interfaces or IP services on those interfaces. An interface can be physical (for example, a Gigabit Ethernet port) or virtual (for example, the Null interface). To enter INTERFACE mode: 1.
ISIS ADDRESS-FAMILY Mode To enable or configure IPv6 for ISIS, use ISIS ADDRESS-FAMILY mode. For more information, refer to Intermediate System to Intermediate System (IS-IS). To enter ISIS ADDRESS-FAMILY mode: 1. Verify that you are logged in to ROUTER ISIS mode. 2. Enter the command address-family ipv6 unicast. The prompt changes to include (conf-router_isis-af_ipv6). LLDP Mode To enable and configure Link Layer Discovery Protocol (LLDP), use LLDP mode.
To enter MONITOR SESSION mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the monitor session command then the session ID. The prompt changes to include (conf-mon-sess-sessionID). MULTIPLE SPANNING TREE (MSTP) Mode To enable and configure MSTP, use MULTIPLE SPANNING TREE mode. For more information, refer to Multiple Spanning Tree Protocol (MSTP). To enter MULTIPLE SPANNING TREE mode: 1. Verify that you are logged in to CONFIGURATION mode. 2.
2. Enter the ip prefix-list command. Include a name for the prefix list. The prompt changes to include (conf-nprefixl). You can return to CONFIGURATION mode by using the exit command. PRIORITY GROUP Mode To create an ETS priority group, use PRIORITY GROUP mode. For more information, refer to ETS Commands. To enter PRIORITY GROUP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the priority-group command then the group name. The prompt changes to include (conf-pg).
ROUTER BGP Mode To enable and configure Border Gateway Protocol (BGP), use ROUTER BGP mode. For more information, refer to Border Gateway Protocol IPv4 (BGPv4) To enter ROUTER BGP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Use the router bgp command then enter the AS number. The prompt changes to include (conf-router_bgp). You can return to CONFIGURATION mode by using the exit command.
SPANNING TREE Mode To enable and configure the Spanning Tree protocol, use SPANNING TREE mode. For more information, refer to Spanning Tree Protocol (STP). To enter SPANNING TREE mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the protocol spanning-tree stp-id command. The prompt changes to include (conf-stp). You can return to CONFIGURATION mode by using the exit command. TRACE-LIST Mode To configure a Trace list, use TRACE-LIST mode. To enter TRACE-LIST mode: 1.
2. Enter the uplink-state-group command then the group ID number. The prompt changes to include (conf-uplink-stategroup-groupID).
3 File Management This chapter contains command line interface (CLI) commands needed to manage the configuration files as well as other file management commands. boot system Tell the system where to access the Dell Networking OS image used to boot the system. Syntax boot system {gateway ip address| stack-unit [{stack-unit-number | all] [default | primary {system {A: | B: | bmp-boot} | tftp: | | secondary]} To return to the default boot sequence, use the no boot system command.
Usage Information Version Description 9.7(0.0) Introduced the support for bmp-boot on the S-Series and Z-Series switches. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. To display these changes in the show bootvar command output, save the running configuration to the startup configuration (using the copy command) and reload system. The keyword bmp-boot is used only when the device boots up from BMP.
Version Description E-Series Original command. HTTP Copy via CLI Copy one file to another location. Dell Networking OS supports IPv4 and IPv6 addressing for FTP, TFTP, and SCP (in the hostip field). This feature is supported on S4820T platform. Syntax copy http://10.16.206.77/sample_file flash://sample_filecopy flash:// sample_file http://10.16.206.77/sample_file You can copy from the server to the switch and vice-versa. Parameters copy http: flash: Address or name of remote host []: 10.16.206.
compressed-config file-url Enter the keyword compressed-config to copy one file, after optimizing and reducing the size of the configuration file, to another location. Dell Networking OS supports IPv4 and IPv6 addressing for FTP, TFTP, and SCP (in the hostip field).
To copy a file from an external USB drive enter usbflash://filepath Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON.
You can compress the running configuration by grouping all the VLANs and the physical interfaces with the same property. Support to store the operating configuration to the startup config in the compressed mode and to perform an image downgrade without any configuration loss are provided. Two existing exec mode CLIs are enhanced to display and store the running configuration in the compressed mode. Example Dell#copy running-config scp:/ Address or name of remote host []: 10.10.10.
• For a file or directory on the NFS mounted file system, enter nfsmount:// followed by the mount point and the file path. NOTE: While deleting a file directory on a remote NFS file system, it is mandatory to specify the mount-point that indicates the working directory on the NFS file system. You cannot delete the root directory of the remote NFS file system. • no-confirm For a file or directory on an external USB drive, enter usbflash:// followed by the filename or directory name.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Added support for NFS mount. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 7.8.1.
Usage Information Include the colon (:) when entering this command. This command checks the specified flash memory for errors. If errors are found, the command recommends that you format the flash. CAUTION: If you elect to format the flash, all files – including the startup configuration file – are lost. If you do decide to format the specified flash, consider saving the running configuration as the startup configuration after formatting the flash (use the write memory command or copy run start command).
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S-Series. Example Dell#mount nfs nfstest nfs-mount-point usrname pwd Related Commands cd – changes the working directory. rmdir Removes a directory from the NFS mounted file system.
nfsmount:// / filepath Enter the keyword nfsmount: and specify the location of the image file in the format //
rename Rename a file in the local file system. Syntax rename url url Parameters url Enter the following keywords and a filename: • For a file on the internal Flash, enter flash:// followed by the filename. • For a file on an NFS mounted file system, enter nfsmount:// followed by the mount point and file path. • For a file on an external USB drive, enter usbflash:// followed by the filename. Command Modes EXEC Privilege Command History This guide is platform-specific.
nvram Enter the keyword nvram to reset the NvRAM only. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.5(0.1) Added bootvar as a new parameter. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.
• secondary_server, secondary_file, and secondary_type • default_server, default_file, and default_type NOTE: For information on the default values that these variables take, refer to the Restoring Factory Default Environment Variables section in the Dell Networking OS Configuration guide.
Example (NvRAM, single unit) Dell#restore factory-defaults stack-unit 1nvram ************************************************************** * Warning - Restoring factory defaults will delete the existing * * persistent settings (stacking, fanout, etc.) * * After restoration the unit(s) will be powercycled immediately.
Type Boot Type A B ---------------------------------------------------------------Stack-unit 1 FLASH BOOT 9-0(2-1) 9-0(2-0)[boot] Dell# show bootvar Display the variable settings for the boot parameters. Syntax show bootvar Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
show file-systems Display information about the file systems on the system. Syntax show file-systems Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Command Fields Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.
Related Commands format flash (S-Series) – Erases all the existing files and reformats the filesystem in the internal flash memory on the S-Series. show running-config Display the current configuration and display changes from the default values.
interface port-channel for the current port-channel interface configuration. The range is from 1 to 128. interface tunnel for all configured tunnels. For a specific tunnel, enter the tunnel ID. The range is from 1 to 16383.
rip for the current RIP configuration rmon for the current RMON configuration route-map for the current route map configuration sflow for the current sFlow configuration snmp for the current SNMP configuration spanning-tree for the current spanning tree configuration static for the current static route configuration status for the file status information tacacs+ for the current TACACS+ configuration tftp for the current TFTP configuration trace-group for the current trace-group configur
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Expanded to include the last configuration change, start-up last updated (date and time), and who made the change. 6.5.4.0 Added the status option. Example Dell# show running-config Current Configuration ...
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on S-Series 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Expanded to include the last configuration change, start-up last updated (date and time), and who made the change.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command.
The following is a list of the Dell Networking OS version history for this command. Command Fields Example (S-Series) Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series 7.5.1.0 Introduced on the C-Series. E-Series Original command. Lines Beginning With Description Dell Network...
4 Ten GigabitEthernet/IEEE 802.3 interface(s) Dell# Example (S4810) Dell# Dell#show version Dell Real Time Operating System Software Dell Operating System Version: 1.0 Dell Application Software Version: Z9K-ICC-PRIM-SYNC-8-3-11-173 Copyright (c) 1999-2012 by Dell Inc. All Rights Reserved. Build Time: Mon Jul 16 22:19:01 PDT 2012 Build Path: /local/local/build/build15/8.3.12.
flash: After entering the keyword flash:, you can either follow it with the location of the source file in filepath or press Enter to launch a prompt sequence. A: | B: Enter the partition to upgrade from the flash. stack-unit: Enter the keywords stack-unit: to synch the image to the stack-unit.
.................................................................................... .................................................................................... .................................................................................... ....................................! 12946259 bytes successfully copied Dell# reload verify Validate the software image on the flash drive after the image has been transferred to the system, but before the image has been installed.
SHA256 hash VERIFIED for FTOS-SE-9.5.0.0.
4 Control and Monitoring This chapter contains the commands to configure and monitor the system, including Telnet, file transfer protocol (FTP), and trivial file transfer protocol (TFTP). NOTE: This command replaces the enable optic-info-update interval command to update information on temperature and power monitoring in the simple network management protocol (SNMP) management information base (MIB).
banner exec Configure a message that is displayed when your enter EXEC mode. Syntax banner exec c line c To delete a banner, use the no banner exec command. Parameters c Enter the keywords banner exec, then enter a character delineator, represented here by the letter c. Press ENTER. line Enter a text string for your banner message ending the message with your delineator. In the following example, the delineator is a percent character (%); the banner message is “testing, testing”.
Press RETURN to get started. 4d21h6m: %RPM0-P:CP %SEC-5-LOGIN_SUCCESS: Login successful for user on line console This is the banner Dell> Related Commands line — enables and configures the console and virtual terminal lines to the system. banner login Set a banner to display when logging on to the system. Syntax banner login {keyboard-interactive | no keyboard-interactive} [c line c] Enter no banner login to delete the banner text.
Usage Information After entering the banner login command, type one or more spaces and a delineator character. Enter the banner text then the second delineator character. When the user is connected to the router, if a message of the day banner is configured, it displays first. If no message of the day banner is configured, the login banner and prompt appear. After the user has logged in, the banner EXEC (if configured) displays.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command Usage Information After entering the banner login command, type one or more spaces and a delineator character.
Enter 4 or 8 for the number of OpenFlow FP blocks. • 4: Creates 242 entries for use by the OpenFlow controller (256 total entries minus the 14 entries reserved for internal functionality) • 8: Creates 498 entries for use by the OpenFlow controller (512 total entries minus the 14 entries reserved for internal functionality) Using the fcoe parameter, enter the number of FP groups to be allocated for FCoE transit. Enter 1 – 6; maximum six groups.
cam-acl-vlan Specify the number of VFP blocks allocated to OpenFlow. Syntax cam-acl-vlan vlanopenflow {0|1} Defaults Disabled. Parameters vlanopenflow Enter the number 1 to allocate VFP blocks and enable OpenFlow. (Default) Enter the number 0 to disable OpenFlow. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. configure Enter CONFIGURATION mode from EXEC Privilege mode.
disable Return to EXEC mode. Syntax Parameters disable [level] level (OPTIONAL) Enter a number for a privilege level of the Dell Networking OS. The range is from 0 to 15. The default is 1. Defaults 1 Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Usage Information Version Description 9.5(0.0) Added support for roles on the Z9000, S6000, S4820T, S4810, and MXL. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command.
Usage Information Version Description 8.3.11.4 Replacement command for the Z9000. Replaces the enable xfp-powerupdates command 8.3.10.0 Replacement command for the S4810 only. Replaces the enable xfp-powerupdates command. To enable polling and to configure the polling frequency, use this command. end Return to EXEC Privilege mode from other command modes (for example, CONFIGURATION or ROUTER OSPF modes).
Related Commands Version Description E-Series Original command. exit — returns to the lower command mode. exec-timeout Set a time interval that the system waits for input on a line before disconnecting the session. Syntax exec-timeout minutes [seconds] To return to default settings, use the no exec-timeout command. Parameters minutes Enter the number of minutes of inactivity on the system before disconnecting the current session. The range is from 0 to 35791.
exit Return to the lower command mode. Syntax exit Command Modes Command History • EXEC Privilege • CONFIGURATION • LINE, INTERFACE • TRACE-LIST • PROTOCOL GVRP • SPANNING TREE • MULTIPLE SPANNING TREE • MAC ACCESS LIST • ACCESS-LIST • AS-PATH ACL • COMMUNITY-LIST • PREFIX-LIST • ROUTER OSPF • ROUTER RIP • ROUTER ISIS • ROUTER BGP This guide is platform-specific.
ftp-server enable Enable FTP server functions on the system. Syntax Parameters ftp-server [vrf vrf-name] enable vrf vrf-name Enter the keyword vrf and then the name of the VRF to enable the FTP server to listen to that VRF instance. NOTE: Use this attribute to specify the VRF that is used by the FTP server to accept client connections. If no VRF is specified, then the default VRF is used. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
329 bytes received in 0.018 seconds (17.95 Kbytes/s) ftp> ftp-server topdir Specify the top-level directory to be accessed when an incoming FTP connection request is made. Syntax ftp-server topdir directory Parameters directory Enter the directory path. Defaults The internal flash is the default directory. Command Modes CONFIGURATION Command History This guide is platform-specific.
To delete a user name and its password, use the no ftp-server username username command. Parameters username Enter a text string up to 40 characters long as the user name. password password Enter the keyword password then a string up to 40 characters long as the password. Without specifying an encryption type, the password is unencrypted.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. The password is listed in the configuration file; you can view the password by entering the show running-config ftp command. Use the ip ftp password command when you use the ftp: parameter in the copy command.
ip ftp source-interface Specify an interface’s IP address as the source IP address for FTP connections. Syntax ip ftp source-interface interface To delete an interface, use the no ip ftp source-interface interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
To return to anonymous FTP connections, use the no ip ftp username [username] command. Parameters username Enter a text string as the user name up to 40 characters long. Defaults No user name is configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. ip ssh server — enables the secure shell (SSH) server on the system. ip telnet server vrf Configures the TELNET server on either a specific VRF or a management VRF.
ip telnet source-interface Set an interface’s IP address as the source address in outgoing packets for Telnet sessions. Syntax ip telnet source-interface interface To return to the default setting, use the no ip telnet source-interface [interface] command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
ip tftp source-interface Assign an interface’s IP address in outgoing packets for TFTP traffic. S4820T Syntax ip tftp source-interface interface To return to the default setting, use the no ip tftp source-interface interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
ip tftp vrf Configures an TFTP client with a VRF that is used to connect to the TFTP server. Syntax ip tftp [vrf vrf-name] To undo the TFTP client configuration, use the no ip tftp [vrf vrf-name] command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to specify the VRF that is used by the TFTP client. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Defaults Not configured Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Introduced on the S4810, S4820, S4048–ON, S3048–ON, S5000, S6000, S6000ON, and Z9500.
5 vty 3 10.14.1.97 Clear existing session? [line number/Enter to cancel]: Related Commands login statistics — Enable and configure user login statistics on console and virtual terminal lines. show login statistics — Displays login statistics of users who have used the console or virtual terminal lines to log in to the system. login statistics Enable and configure user login statistics on console and virtual terminal lines.
Example When you log into the system, it displays a message similar to the following: $ telnet 10.11.178.14 Trying 10.11.178.14... Connected to 10.11.178.14. Escape character is '^]'. Login: admin Password: Last successful login: Mon Feb 16 04:36:11 2015 Line vty0 ( 10.14.1.97 ). There were 2 unsuccessful login attempt(s) since the last successful login. There were 3 unsuccessful login attempt(s) for user admin in last 30 day(s).
Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command ping Test connectivity between the system and another device by sending echo requests and waiting for replies.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. • For a Tunnel interface, enter the keyword tunnel then a number from 1 to 16383. tos (IPv4 only) Enter the type of service required. The range is from 0 to 255. The default is 0.
The following is a list of the Dell Networking OS version history for this command. Version 9.0.2.0 Introduced on the S6000. Version 9.0.0.0 Introduced on the Z9000. Version 8.3.19.0 Introduced on the S4820T. Added support for the outgoing-interface option for link-local IPv6 addressing on the S4820T. Usage Information Version 8.3.12.0 Added support for the outgoing-interface option for link-local IPv6 addressing on the S4810. Version 8.3.11.1 Introduced on the Z9000. Version 8.3.7.
:: Reply to request 5 from 172.31.1.209 0 ms Reply to request 5 from 172.31.1.66 0 ms Reply to request 5 from 172.31.1.87 0 ms Dell# Example (IPv6) Dell#ping 100::1 Type Ctrl-C to abort. Sending 5, 100-byte ICMP Echos to 100::1, timeout is 2 seconds: !!!!! Success rate is 100.0 percent (5/5), round-trip min/avg/max = 0/0/0 (ms) Dell# reload Reboot Dell Networking Operating System (OS). Syntax Parameters reload [conditional nvram-cfg-change] conditional nvramcfg-change Reload if the condition is true.
send Send messages to one or all terminal line users. Syntax send [*] | [line ] | [console] | [vty] Parameters * Enter the asterisk character * to send a message to all tty lines. line Send a message to a specific line. The range is from 0 to 11. console Enter the keyword console to send a message to the primary terminal line. vty Enter the keyword vty to send a message to the virtual terminal. Defaults none Command Modes EXEC Command History This guide is platform-specific.
log (OPTIONAL) Enter the keyword log to add timestamps to log messages with severity from 0 to 6. datetime (OPTIONAL) Enter the keyword datetime to have the current time and date added to the message. localtime (OPTIONAL) Enter the keyword localtime to include the localtime in the timestamp. msec (OPTIONAL) Enter the keyword msec to include milliseconds in the timestamp. show-timezone (OPTIONAL) Enter the keyword show-timezone to include the time zone information in the timestamp.
Parameters Command Modes Command History threshold • EXEC • EXEC Privilege (OPTIONAL) Enter the keyword threshold to display the temperature thresholds in Celcuis for each level. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
show cam-acl-vlan Display the block sizes allocated for the VLAN CAM ACL. S4820T Syntax show cam-acl-vlan Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description Version 9.1.(0.0) Introduced on S4810. Version 8.3.19.0 Introduced on the S4820T.
console [11/20 15:47:22]: CMD-(CLI):[service password-encryption hostname Force10]by default from console - Repeated 3 times.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
all (OPTIONAL) Enter the keyword all to display traffic statistics on all the interfaces receiving traffic, sorted based on the traffic. cp (OPTIONAL) Enter the keyword cp to display traffic statistics on the specified CPU. Defaults all Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show debugging View a list of all enabled debugging processes. Syntax show debugging Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000.
pem Command Modes Command History • EXEC • EXEC Privilege Enter the keyword pem to view only information on power entry modules. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.
0 0 1 2 up up up up 6971 7021 up up 7072 6971 Speed in RPM Dell#show environment pem -- Power Supplies -Unit Bay Status Type FanStatus FanSpeed(rpm) --------------------------------------------------------------------------0 0 down UNKNOWN down 0 0 1 up AC up 6504 Dell#show environment thermal-sensor -- Thermal Sensor Readings (deg C) -- Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6 ----------------------------------------------------------------------------------0 39 36 37 37 31 31
Usage Information If there are no fiber ports in the unit, just the header under show inventory media displays. If there are fiber ports but no o present or accessible. Example (S6000) Dell#show inventory System Type System Mode Software Version : S6000 : 1.
unsuccessfulattempts (Optional)Displays the number of failed login attempts by the current user in the last 30 days or the custom defined time period. time-period days (Optional)Displays the number of failed login attempts by the current user in the specified period. Defaults None Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
-----------------------------------------------------------------User: secadm Last login time: Mon Feb 16 04:45:29 2015 Last login location: Line vty0 ( 10.14.1.97 ) Unsuccessful login attempt(s) since the last successful login: 0 Unsuccessful login attempt(s) in last 7 day(s): 0 -----------------------------------------------------------------The following is sample output of the show login statistics user user-id command.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.
Refer to Example (stack-unit). summary Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Enter the keywordsummary to view CPU utilization of processes related to stack-unit processing. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON.
0xbad44000 50 0 sysAdmTsk 0xbad58000 650 0 timerMgr 0xbad6e000 50 0 PM 0xbad85000 1190 0 KP 0xbad9a000 0 0 evagt 0xbadb4000 30 0 ipc 0xbadc9000 10 0 sysReaper 0xbae22000 60 0 tme Dell#show processes cpu <1-99> seconds details | Dell#show processes cpu 5 10000 0.00% 0.00% 0.00% 65 10000 0.00% 0.00% 0.00% 5 10000 0.00% 0.00% 0.00% 119 10000 0.00% 0.00% 0.00% 0 0 0.00% 0.00% 0.00% 3 10000 0.00% 0.00% 0.00% 1 10000 0.00% 0.00% 0.00% 6 10000 0.00% 0.00% 0.
details | Detail CPU utilization Pipe through a command Dell#show processes cpu management-unit CPUID 5sec 1min 5min -------------------------------------------------CORE 0 9.54 9.92 12.82 CORE 2 10.74 11.56 14.31 Overall 10.14 10.74 13.
show processes ipc flow-control Display the single window protocol queue (SWPQ) statistics. Syntax Parameters Defaults Command Modes Command History show processes ipc flow-control [cp] cp (OPTIONAL) Enter the keyword cp to view the control processor’s SWPQ statistics. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Field Description Retr /Available Retra Number of retries left Total/ Max Retra Number of retries allowed Important Points: Example (S-Series) • The SWP provides flow control-based reliable communication between the sending and receiving software tasks. • A sending task enqueues messages into the SWP queue3 for a receiving task and waits for an acknowledgement.
Usage Information Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.7.1.0 Added the management-unit option. 7.6.1.0 Introduced on the S-Series.
ifagt_1 21318 dsagt 6504 MacAgent 269778 Example (management-unit) 16564 0 0 21318 6504 269778 4754 6504 269778 Dell#show processes management-unit Total : 151937024, MaxUsed : 111800320 [2/25/2008 4:18:53] CurrentUsed: 98848768, CurrentFree: 53088256 SharedUsed : 13007848, SharedFree : 7963696 PID Process ResSize Size Allocs Frees Max Current 337 KernLrnAgMv 117927936 0 0 0 0 0 331 vrrp 5189632 249856 50572 0 50572 50572 323 frrp 5206016 241664 369238 0 369238 369238 322 xstp 7430144 2928640 38328 0 38
• stack-unit unit-ID For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Enter the keyword stack-unit then the stack member number to display IFM information for that unit. NOTE: This option is only available on the S-Series. trace-flags Defaults Command Modes Command History Enter the keyword trace-flags to display IFM information for internal trace flags. none • EXEC • EXEC Privilege This guide is platform-specific.
show system Display the status of all stack members or a specific member. Syntax show system [brief | stack-unit unit-id | stack-ports {status | topology}] Parameters brief (OPTIONAL) Enter the keyword brief to view an abbreviated list of system information. stack-unit unit-id (OPTIONAL) Enter the keywords stack-unit then the stack member ID for information on that stack member. The unit ID range for the S4820T is from 0 to 11.
-- Stack Info -Unit UnitType Status ReqTyp CurTyp Version Ports -----------------------------------------------------------------------------------0 Management online S6000 S6000 9-4(0-168) 128 1 Member not present 2 Member not present 3 Member not present 4 Member not present 5 Member not present -- Power Supplies -Unit Bay Status Type FanStatus FanSpeed(rpm) --------------------------------------------------------------------------0 0 down UNKNOWN down 0 0 1 up AC up 6600 -- Fan Status -Unit Bay TrayStat
Example (S4810) Unit Type Status : Member Unit : not present -- Unit 3 -Unit Type Status : Member Unit : not present -- Unit 4 -Unit Type Status : Member Unit : not present -- Unit 5 -Unit Type Status : Member Unit : not present Dell#show system stack-unit 0 -- Unit 0 -Unit Type : Management Unit Status : online Next Boot : online Required Type : S6000 - 32-port TE/FG (SI) Current Type : S6000 - 32-port TE/FG (SI) Master priority : 0 Hardware Rev : 4.
Status : Card Problem - Software Failure Next Boot : online Required Type : S6000-ON - 32-port TE/FG (SI-ON) Current Type : S6000-ON - 32-port TE/FG (SI-ON) Master priority : 0 Hardware Rev : 3.0 Num Ports : 128 Up Time : 3 day, 22 hr, 33 min Dell Networking OS Version : 9-7(0-288) Jumbo Capable : yes POE Capable : no FIPS Mode : disabled Boot Flash : Present Boot Selector : 3.20.0.
page (OPTIONAL) Enter the keyword page to view 24 lines of text at a time. Press the SPACE BAR to view the next 24 lines. Press the ENTER key to view the next line of text. When using the pipe command ( | ), enter one of these keywords to filter command output. For details about filtering commands, refer to CLI Basics. save Enter the keyword save to save the command output. flash: Save to local flash drive (flash://filename. A maximum of 20 characters.
Example (S-Series) • show ip management route • show ip route summary • show Inventory • show log summary • show command-history (last 20 commands) • show log Dell#show tech-support ? page Page through output stack-unit Unit Number | Pipe through a command Dell#show tech-support stack-unit 1 ? | Pipe through a command Dell#show tech-support stack-unit 1 | ? except Show only text that does not match a pattern find Search for the first occurrence of a pattern grep Show only text that ma
-----------------------Current Configuration ... ! Version 9-4(0-168) ! Last configuration change at Tue Mar 25 17:43:06 2014 by admin ! boot system stack-unit 0 primary tftp://10.16.127.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.11.1 Introduced on the S-Series. telnet Connect through Telnet to a server. The Telnet client and server in Dell Networking support IPv4 and IPv6 connections. You can establish a Telnet session directly to the router or a connection can be initiated from the router. NOTE: The Telnet server and client are VRF-aware.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.11.
Version Description 7.5.1.0 Introduced on the C-Series. E-Series Original command. traceroute View a packet’s path to a specific device. Syntax traceroute {host | vrf instance | ip-address | ipv6-address} Parameters host Enter the name of device. ip-address Enter the IP address of the device in dotted decimal format. ipv6-address Enter the IPv6 address, in the x:x:x:x::x format, to which you are testing connectivity. NOTE: The :: notation specifies successive hexadecimal fields of zeros.
Usage Information Version Description 7.6.1.0 Added support for the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for IPv6 address on the E-Series. E-Series Original command.
undebug all Disable all debug operations on the system. Syntax undebug all Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. E-Series Original command.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. Usage Information The write memory command saves the running-configuration to the file labeled startup-configuration.
5 802.1ag 802.1ag is available on the Dell Networking OS. ccm disable Disable continuity check message (CCM). Syntax ccm disable Enter no ccm disable to enable CCM. Defaults Disabled Command Modes ECFM DOMAIN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.
Version Description Version 8.3.19.0 Introduced on the S4820T. Version 8.3.11.1 Introduced on the Z9000. Version 8.3.7.0 Introduced on the S4810. Version 8.3.1.0 Introduced on the S-Series. clear ethernet cfm traceroute-cache Delete all link trace cache entries. Syntax clear ethernet cfm traceroute-cache Defaults none Command Modes ECFM DOMAIN Command History This guide is platform-specific.
Version Description 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. disable Disable Ethernet CFM without stopping the CFM process. Syntax disable Defaults Disabled Command Modes ETHERNET CFM Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.
Version Description 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. ethernet cfm Spawn the CFM process. No CFM configuration is allowed until the CFM process is spawned. Syntax ethernet cfm Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. ethernet cfm mip Create a maintenance intermediate point (MIP).
Parameters mep-id Enter the MEP ID. The range is from 1 to 8191. Defaults none Command Modes ECFM DOMAIN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.
mep cross-check start-delay Configure the amount of time the system waits for a remote MEP to come up before the cross-check operation is started. Syntax Parameters mep cross-check start-delay number start-delay number Enter a start-delay in seconds. The range is from 3 to 100 seconds. Defaults 3 ccms Command Modes ETHERNET CFM Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. show ethernet cfm domain Display maintenance domain information. Syntax show ethernet cfm domain [name | level | brief] Parameters name | level Enter the maintenance domain name or level. brief Enter the keyword brief to display a summary output.
show ethernet cfm maintenance-points local Display configured MEPs and MIPs. Syntax Parameters show ethernet cfm maintenance-points local [mep | mip] mep Enter the keyword mep to display configured MEPs. mip Enter the keyword mip to display configured MIPs. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
domain [name | level] Enter the keyword domain then the domain name or domain level. expired Enter the keyword expired to view MEP entries that have expired due to connectivity failure. waiting Enter the keyword waiting to display MEP entries waiting for response. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 8.3.1.0 Introduced on the S-Series. show ethernet cfm statistics Display MEP statistics. Syntax Parameters show ethernet cfm statistics [domain {name | level} vlan-id vlan-id mpid mpid] domain Enter the keyword domain to display statistics for a particular domain. name | level Enter the domain name or level. vlan-id vlan-id Enter the keyword vlan-id then a VLAN ID. mpid mpid Enter the keyword mpid then a maintenance point ID.
show ethernet cfm port-statistics Display CFM statistics by port. Syntax show ethernet cfm port-statistics [interface type slot/port[]] Parameters interface type Enter the keyword interface then the interface type. slot/port[] Enter the slot and port numbers for the port. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Next Host Egress MAC Egress Action -------------------------------------------------------4 00:00:00:01:e8:53:4a:f8 00:01:e8:52:4a:f8 IngOK 00:00:00:01:e8:52:4a:f8 FWD Status RlyHit Terminal MEP service Create maintenance association. Syntax Parameters service name vlan vlan-id name Enter a maintenance association name. vlan vlan-id Enter the keyword vlan and then enter the VLAN ID. The range is from 1 to 4094.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. traceroute cache size Set the size of the link trace cache. Syntax traceroute cache size entries Parameters entries Enter the number of entries the link trace cache can hold. The range is from 1 to 4095 entries. Defaults 100 entries Command Modes ETHERNET CFM Command History This guide is platform-specific.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the S-Series. 802.
6 802.1X An authentication server must authenticate a client connected to an 802.1X switch port. Until the authentication, only extensible authentication protocol over LAN (EAPOL) traffic is allowed through the port to which a client is connected. After authentication is successful, normal traffic passes through the port. The Dell Networking operating software supports remote authentication dial-in service (RADIUS) and active directory environments using 802.1X Port Authentication.
interface interface Restricts the debugging information to an interface. Defaults Disabled Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Introduced on the C-Series and S-Series. If the host responds to 802.1X with an incorrect login/password, the login fails. The switch attempts to authenticate again until the maximum attempts configured is reached. If the authentication fails after all allowed attempts, the interface moves to the authentication failed VLAN.
dot1x auth-type mab-only To authenticate a device with MAC authentication bypass (MAB), only use the host MAC address. Syntax dot1x auth-type mab-only Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
dot1x guest-vlan Configure a guest VLAN for limited access users or for devices that are not 802.1X capable. Syntax dot1x guest-vlan vlan-id To disable the guest VLAN, use the no dot1x guest-vlan vlan-id command. Parameters vlan-id Enter the VLAN Identifier. The range is from 1 to 4094. Defaults Not configured. Command Modes CONFIGURATION (conf-if-interface-slot/port) Command History This guide is platform-specific.
dot1x host-mode Enable single-host or multi-host authentication. Syntax dot1x host-mode {single-host | multi-host | multi-auth} Parameters single-host Enable single-host authentication. multi-host Enable multi-host authentication. multi-auth Enable multi-supplicant authentication. Defaults single-host Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
Version Description 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x max-supplicants Restrict the number of supplicants that can be authenticated and permitted to access the network through the port. This configuration is only takes effect in Multi-auth mode. Syntax dot1x max-supplicants number Parameters number Enter the number of supplicants that can be authenticated on a single port in Multi-auth mode.
force-unauthorized Enter the keywords force-unauthorized to forcibly de-authorize a port. Defaults none Command Modes Auto Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.
Version Description 8.3.12.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x reauthentication Enable periodic reauthentication of the client. Syntax dot1x reauthentication [interval seconds] To disable periodic reauthentication, use the no dot1x reauthentication command. Parameters interval seconds (Optional) Enter the keyword interval then the interval time, in seconds, after which reauthentication is initiated.
Parameters number Enter the permitted number of re-authentications. The range is from 1 to 10. The default is 2. Defaults 2 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. When you configure the dot1x server-timeout value, take into account the communication medium used to communicate with an authentication server and the number of RADIUS servers configured.
Version Description 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x tx-period Configure the intervals at which EAPOL PDUs the Authenticator PAE transmits. Syntax dot1x tx-period seconds To return to the default, use the no dot1x tx-period command. Parameters seconds Enter the interval time, in seconds, that EAPOL PDUs are transmitted. The range is from 1 to 65535. The default is 30.
mac-address Defaults • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. (Optional) MAC address of an 802.1X-authenticated supplicant. none Command Modes Command History • EXEC • EXEC privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
802.1p CoS re-map table for Supplicant: 00:00:00:00:00:10 Dot1p 0 1 2 3 4 5 6 7 Dell# Remapped Dot1p 7 6 5 4 3 2 1 0 show dot1x interface Display the 802.1X configuration of an interface. Syntax Parameters show dot1x interface interface [mac-address mac-address] interface mac-address Defaults Command Modes Command History Enter one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Usage Information If you enable 802.1X multi-supplicant authentication on a port, additional 802.1X configuration details (Port Authentication status, Untagged VLAN ID, Authentication PAE state, and Backend state) display for each supplicant, as shown in the following example. Example Dell#show dot1x interface tengigabitethernet 1/32 802.
Dell# show dot1x interface tengigabitethernet 1/32 mac-address 00:00:00:00:00:11 Supplicant Mac: 0 0 0 0 0 10 Lookup for Mac: 802.
00:00:00:00:00:11 Supplicant Mac: 0 0 0 0 0 10 Lookup for Mac: 802.
7 Access Control Lists (ACL) Access control lists (ACLs) are supported by the Dell Networking OS.
Command History • CONFIGURATION-EXTENDED-ACCESS-LIST • CONFIGURATION-MAC ACCESS LIST-STANDARD • CONFIGURATION-MAC ACCESS LIST-EXTENDED This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
• Command History CONFIGURATION-MAC ACCESS LIST-EXTENDED This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.1.
Defaults Not configured. Command Modes LINE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the ipv4 and ipv6 parameters to the command. Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Parameters access-list-name (OPTIONAL) Enter the name of a configured access-list, up to 140 characters. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
NOTE: When you specify a single VRF, use the name of the VRF instead of the VRF ID number. Use the VRF ID numbers only when you specify a range of VRFs. Defaults Not enabled. Command Modes INTERFACE/VRF MODE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
ip control-plane egress-filter Enable egress Layer 3 ACL lookup for IPv4 CPU traffic. Syntax ip control-plane egress-filter Defaults Not enabled. Command Modes EXEC Privilege Command History Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. show ip accounting access-list Display the IP access-lists created on the switch and the sequence of filters.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for the 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. show ip accounting access-lists Description “Extended IP...
deny To drop packets with a certain IP address, configure a filter. Syntax deny {source | any | host {ip-address}} [no-drop] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {source [mask] | any | host ip-address} command. source Enter the IP address in dotted decimal format of the network from which the packet was sent.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. The order option is relevant in the context of the Policy QoS feature only. For more information, refer to the Quality of Service chapter of the Dell Networking OS Configuration Guide.
Usage Information Version Description 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. Dell Networking OS supports one ingress and one egress IP ACL per interface. Prior to Dell Networking OS version 7.8.1.0, names are up to 16 characters long. The number of entries allowed per ACL is hardware-dependent.
Defaults Not configured. Command Modes CONFIGURATION-STANDARD-ACCESS-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
The following is a list of the Dell Networking OS version history for this command. Version 9.0.2.0 Introduced on the S6000. Version 8.3.11.1 Introduced on the Z9000. Version 8.1.1.0 Introduced on the E-Series ExaScale Version 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names were up to 16 characters long. Version 7.6.1.0 Introduced on the S-Series. Version 7.5.1.0 Introduced on the C-Series. Version 7.4.1.0 Introduced on the E-Series.
no-drop Enter the keywords no-drop to match only the forwarded packets. Defaults Not configured Command Modes CONFIGURATION-STANDARD-ACCESS-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.
The following commands configure extended IP ACLs, which in addition to the IP address, also examine the packet’s protocol type. The platform supports both Ingress and Egress IP ACLs. NOTE: Also refer to the Commands Common to all ACL Types and Common IP ACL Commands sections. deny Configure a filter that drops IP packets meeting the filter criteria.
Command Modes CONFIGURATION-EXTENDED-ACCESS-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
deny icmp To drop all or specific internet control message protocol (ICMP) messages, configure a filter. Syntax deny icmp {source mask | any | host ip-address} {destination mask | any | host ip-address} [dscp] [count [byte] [order] [fragments] [no-drop] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny icmp {source mask | any | host ip-address} {destination mask | any | host ip-address} command.
Usage Information Version Description 8.3.1.0 Added the keyword dscp. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.4.1.0 Added support for non-contiguous mask and added the monitor option. 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. The order option is relevant in the context of the Policy QoS feature only.
port port • gt = greater than • lt = less than • range = inclusive range of ports (you must specify two ports for the port command) Enter the application layer port number. Enter two port numbers if using the range logical operand. The range is from 0 to 65535. The following list includes some common TCP port numbers: • 23 = Telnet • 20 and 21 = FTP • 25 = SMTP • 169 = SNMP destination Enter the IP address of the network or host to which the packets are sent.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for non-contiguous mask and added the monitor option. Deprecated the keyword established. 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. The order option is relevant in the context of the Policy QoS feature only. For more information, refer to the Quality of Service chapter of the Dell Networking OS Configuration Guide.
deny udp To drop user datagram protocol (UDP) packets meeting the filter criteria, configure a filter. Syntax deny udp {source mask | any | host ip-address} [operator port [port]] {destination mask | any | host ip-address} [dscp] [operator port [port]] [count [byte] [order] [fragments] [no-drop] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Total Ports: 4001 Example An ACL rule with a TCP port lt 1023 uses only one entry in the CAM. Rule# Data Mask From To 1 0000000000000000 1111110000000000 0 #Covered 1023 1024 Total Ports: 1024 Related Commands deny — assigns a filter to deny IP traffic. deny tcp — assigns a filter to deny TCP traffic. ip access-list extended Name (or select) an extended IP access list (IP ACL) based on IP addresses or protocols.
Example Dell(conf)#ip access-list extended TESTListEXTEND Dell(config-ext-nacl)# Related Commands ip access-list standard — configures a standard IP access list. show config — displays the current configuration. permit To pass IP packets meeting the filter criteria, configure a filter.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Add the DSCP value for ACL matching. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.
bit Enter a flag or combination of bits: • ack: acknowledgement field • fin: finish (no more data from the user) • psh: push function • rst: reset the connection • syn: synchronize sequence numbers • urg: urgent field dscp Enter the keyword dscp to deny a packet based on the DSCP value. The range is from 0 to 63.
Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Added the keyword dscp. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.
1 0000000000000000 1111110000000000 0 1023 1024 Total Ports: 1024 Related Commands ip access-list extended — creates an extended ACL. permit — assigns a permit filter for IP packets. permit udp — assigns a permit filter for UDP packets. permit udp To pass UDP packets meeting the filter criteria, configure a filter.
lowest; lower-order numbers have a higher priority). If you do not use the keyword order, the ACLs have the lowest order by default (255). fragments Enter the keyword fragments to use ACLs to control packet fragments. no-drop Enter the keywords no-drop to match only the forwarded packets. Defaults Not configured. Command Modes CONFIGURATION-EXTENDED-ACCESS-LIST Command History This guide is platform-specific.
2 3 4 5 6 7 8 0000111111000000 0001000000000000 0001100000000000 0001110000000000 0001111000000000 0001111100000000 0001111101000000 1111111111000000 1111100000000000 1111110000000000 1111111000000000 1111111100000000 1111111111000000 1111111111111111 4032 4096 6144 7168 7680 7936 8000 4095 6143 7167 7679 7935 7999 8000 64 2048 1024 512 256 64 1 Total Ports: 4001 Example An ACL rule with a TCP port lt 1023 uses only one entry in the CAM.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale (IPv4). 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names were up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. When all sequence numbers are exhausted, this feature permits re-assigning a new sequence number to entries of an existing access-list.
seq Assign a sequence number to a deny or permit filter in an extended IP access list while creating the filter. Syntax Parameters seq sequence-number {deny | permit} {ip-protocol-number | icmp | ip | tcp | udp} {source mask | any | host ip-address} {destination mask | any | host ip-address} [operator port [port]] [count [byte] | log] [dscp value] [order] [monitor] [fragments] [no-drop] sequence-number Enter a number from 0 to 4294967290. The range is from 0 to 65534.
destination Enter the IP address of the network or host to which the packets are sent. count (OPTIONAL) Enter the keyword count to count packets the filter processes. byte (OPTIONAL) Enter the keyword byte to count bytes the filter processes. log (OPTIONAL, E-Series only) Enter the keyword log to enter ACL matches in the log. Supported on Jumbo-enabled line cards only. dscp (OPTIONAL) Enter the keyword dcsp to match to the IP DCSCP values.
Usage Information Version Description 6.5.10 Expanded to include the optional QoS order priority for the ACL entry. The monitor option is relevant in the context of flow-based monitoring only. For more information, refer to Port Monitoring. The order option is relevant in the context of the Policy QoS feature only. The following applies: • The seq sequence-number command is applicable only in an ACL group.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.
Defaults none Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series 6.1.1.0 Introduced on the E-Series.
byte (OPTIONAL) Enter the keyword byte to count bytes processed by the filter. log (OPTIONAL, E-Series only) Enter the keyword log to log the packets. monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. For more information, refer to the “Flow-based Monitoring” section in the Port Monitoring chapter of the Dell Networking OS Configuration Guide.
Parameters mac-list-name Enter a text string as the name of the standard MAC access list (140 character maximum). Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.
Parameters any Enter the keyword any to forward all packets received with a MAC address. mac-sourceaddress Enter a MAC address in nn:nn:nn:nn:nn:nn format. mac-sourceaddress-mask (OPTIONAL) Specify which bits in the MAC address must match. If no mask is specified, a mask of 00:00:00:00:00:00 is applied (in other words, the filter allows only MAC addresses that match). count (OPTIONAL) Enter the keyword count to count packets processed by the filter.
seq —configure a MAC ACL filter with a specified sequence number. seq To a deny or permit filter in a MAC access list while creating the filter, assign a sequence number. Syntax seq sequence-number {deny | permit} {any | mac-source-address [mac-sourceaddress-mask]} [count [byte]] [log] [monitor] [no-drop] To remove this filter, use the no seq sequence-number command. Parameters sequence-number Enter a number from 0 to 65535.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added the monitor option. 6.1.1.0 Introduced on the E-Series. When you use the log option, the CP processor logs details about the packets that match.
host mac-address Enter the keyword host and then enter a MAC address to drop packets with that host address. mac-sourceaddress Enter a MAC address in nn:nn:nn:nn:nn:nn format. mac-sourceaddress-mask Specify which bits in the MAC address must match. The MAC ACL supports an inverse mask; therefore, a mask of ff:ff:ff:ff:ff:ff allows entries that do not match and a mask of 00:00:00:00:00:00 only allows entries that match exactly.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added the monitor option. 6.1.1.0 Introduced on the E-Series. When you use the log option, the CP processor logs detail the packets that match. Depending on how many packets match the log entry and at what rate, the CP may become busy as it has to log these packets’ details.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names were up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. The number of entries allowed per ACL is hardware-dependent. For detailed specifications about entries allowed per ACL, refer to your line card documentation. Prior to 7.8.1.
host Enter the keyword host then a MAC address to forward packets with that host address. mac-sourceaddress Enter a MAC address in nn:nn:nn:nn:nn:nn format. mac-sourceaddress-mask (OPTIONAL) Specify which bits in the MAC address must match. mac-destinationaddress Enter the destination MAC address and mask in nn:nn:nn:nn:nn:nn format. mac-destinationaddress-mask Specify which bits in the MAC address must be matched.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added the monitor option. 6.1.1.0 Introduced on the E-Series. When you use the log option, the CP processor logs details about the packets that match. Depending on how many packets match the log entry and at what rate, the CP may become busy as it has to log these packets’ details.
mac-destinationaddress-mask Specify which bits in the MAC address must be matched. The MAC ACL supports an inverse mask; therefore, a mask of ff:ff:ff:ff:ff:ff allows entries that do not match and a mask of 00:00:00:00:00:00 only allows entries that match exactly. ethertype operator (OPTIONAL) To filter based on protocol type, enter one of the following Ethertypes: • ev2 - is the Ethernet II frame format. • llc - is the IEEE 802.3 frame format. • snap - is the IEEE 802.3 SNAP frame format.
NOTE: When ACL logging and byte counters are configured simultaneously, byte counters may display an incorrect value. Configure packet counters with logging instead. Related Commands deny — configures a filter to drop packets. permit — configures a filter to forward packets. IP Prefix List Commands When you create an access-list without any rule and then apply it to an interface, the ACL behavior reflects implicit permit. To configure or enable IP prefix lists, use these commands.
deny To drop packets meeting the criteria specified, configure a filter. Syntax deny ip-prefix [ge min-prefix-length] [le max-prefix-length] To delete a drop filter, use the no deny ip-prefix command. Parameters ip-prefix Specify an IP prefix in the network/length format. For example, 35.0.0.0/ 8 means match the first 8 bits of address 35.0.0.0. ge min-prefixlength (OPTIONAL) Enter the keyword ge and then enter the minimum prefix length, which is a number from zero (0) to 32.
Parameters prefix-name Enter a string up to 16 characters long as the name of the prefix list, up to 140 characters long. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-Version 6.1.1.
Defaults Not configured. Command Modes PREFIX-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Example Dell(conf-nprefixl)#show config ! ip prefix-list snickers Dell(conf-nprefixl)# show ip prefix-list detail Display details of the configured prefix lists. Syntax show ip prefix-list detail [prefix-name] Parameters Command Modes Command History prefix-name • EXEC • EXEC Privilege (OPTIONAL) Enter a text string as the name of the prefix list, up to 140 characters. This guide is platform-specific.
Parameters Command Modes Command History prefix-name • EXEC • EXEC Privilege (OPTIONAL) Enter a text string as the name of the prefix list, up to 140 characters. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
set as-path — configures a filter to modify the AS path. description Add a description to this route map. Syntax description {description} To remove the description, use the no description {description} command. Parameters description Enter a description to identify the route map (80 characters maximum). Defaults none Command Modes ROUTE-MAP Command History This guide is platform-specific.
Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set community — specifies a COMMUNITY attribute. match interface To match routes whose next hop is on the interface specified, configure a filter. Syntax match interface interface To remove a match, use the no match interface interface command. Parameters interface Enter the following keywords and slot/port or number information: • .
Related Commands match ip address — redistributes routes that match an IP address. match ip next-hop — redistributes routes that match the next-hop IP address. match ip route-source — redistributes routes that match routes advertised by other routers. match metric — redistributes routes that match a specific metric. match route-type — redistributes routes that match a route type. match tag — redistributes routes that match a specific tag.
match metric — redistributes routes that match a specific metric. match route-type — redistributes routes that match a route type. match tag — redistributes routes that match a specific tag. match ip next-hop To match based on the next-hop IP addresses specified in an IP access list or IP prefix list, configure a filter. Syntax match ip next-hop {prefix-list prefix-list-name} To delete a match, use the no match ip next-hop {prefix-list prefix-list-name} command.
match tag — redistributes routes that match a specific tag. match ip route-source To match based on the routes advertised by routes specified in IP access lists or IP prefix lists, configure a filter. Syntax match ip route-source {prefix-list prefix-list-name} To delete a match, use the no match ip route-source {prefix-list prefix-list-name} command. Parameters prefix-list prefix-listname Enter the keywords prefix-list and then enter the name of configured prefix list, up to 140 characters.
match metric To match on a specified value, configure a filter. Syntax match metric metric-value To delete a value, use the no match metric [metric-value] command. Parameters metric-value Enter a value to match. The range is from zero (0) to 4294967295. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters egp Enter the keyword egp to match routes originating outside the AS. igp Enter the keyword igp to match routes originating within the same AS. incomplete Enter the keyword incomplete to match routes with incomplete routing information. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. match interface — redistributes routes that match the next-hop interface. match ip address — redistributes routes that match an IP address. match ip next-hop — redistributes routes that match the next-hop IP address.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. You can prepend up to eight AS numbers to a BGP route. This command influences best path selection in BGP by inserting a tag or AS number into the AS_PATH attribute. Related Commands match as-path — redistributes routes that match an AS-PATH attribute.
set tag — specify the tag assigned to redistributed routes. set comm-list delete To remove the specified community list from the BGP route’s COMMUNITY attribute, configure a filter. Syntax set comm-list community-list-name delete To insert the community list into the COMMUNITY attribute, use the no set comm-list communitylist-name delete command. Parameters community-listname Enter the name of an established Community list, up to 140 characters. Defaults Not configured.
set community Allows you to assign a BGP COMMUNITY attribute. Syntax set community {community-number | local-as | no-advertise | no-export | none} [additive] To delete a BGP COMMUNITY attribute assignment, use the no set community {communitynumber | local-as | no-advertise | no-export | none} command. Parameters community-number Enter the community number in AA:NN format where AA is the AS number (2 bytes) and NN is a value specific to that autonomous system.
Related Commands Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. match community — redistributes routes that match the COMMUNITY attribute. show ip bgp community — displays BGP community groups. set level To specify the IS-IS level or OSPF area to which matched routes are redistributed, configure a filter.
Related Commands set automatic-tag — computes the tag value of the route. set metric — specifies the metric value assigned to redistributed routes. set metric-type — specifies the metric type assigned to redistributed routes. set tag — specifies the tag assigned to redistributed routes. set local-preference To set the BGP LOCAL_PREF attribute for routers within the local autonomous system, configure a filter.
To delete a setting, enter no set metric. Parameters + (OPTIONAL) Enter + to add a metric-value to the redistributed routes. - (OPTIONAL) Enter - to subtract a metric-value from the redistributed routes. metric-value Enter a number as the new metric value. The range is from zero (0) to 4294967295. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific.
type-2 Enter the keyword type-2 to assign the OSPF Type 2 metric. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set tag To specify a tag for redistributed routes, configure a filter. Syntax set tag tag-value To delete a setting, use the no set tag command. Parameters tag-value Enter a number as the tag. The range is from zero (0) to 4294967295. Defaults Not configured.
set weight To add a non-RFC compliant attribute to the BGP route to assist with route selection, configure a filter. Syntax set weight weight To delete a weight specification, use the no set weight weight command. Parameters weight Enter a number as the weight used by the route meeting the route map specification. The range is from 0 to 65535. The default is router-originated = 32768 and all other routes = 0.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Example Dell#show route-map route-map firpo, permit, sequence 10 Match clauses: Set clauses: tag 34 Dell# Related Commands route-map — configures a route map. AS-Path Commands The following commands configure AS-Path ACLs. ip as-path access-list Enter AS-PATH ACL mode and configure an access control list based on the BGP AS_PATH attribute.
Related Commands match as-path — matches on routes contain a specific AS-PATH. show ip as-path-access-lists Display the all AS-PATH access lists configured on the E-Series. Syntax show ip as-path-access-lists Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. pre-Version 6.1.1.0 Introduced on the E-Series. Dell(conf)#ip community-list TestComList Dell(config-community-list)# show ip community-lists Display configured IP community lists in alphabetic order.
deny (for Standard IP ACLs) To drop packets with a certain IP address, configure a filter. Syntax deny {source | any | host {ip-address}}[count [byte]] [dscp value] [order] [fragments] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {source [mask] | any | host ip-address} command.
both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface. This feature is particularly useful when looking for malicious traffic. It is available for Layer 2 and Layer 3 ingress and egress traffic. You may specify traffic using standard or extended access-lists. This mechanism copies all incoming or outgoing packets on one port and forwards (mirrors) them to another port.
Usage Information Version Description 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled.
To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny tcp {source mask | any | host ip-address} {destination mask | any | host ip-address} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG). Related Commands deny — assigns a filter to deny IP traffic. deny udp — assigns a filter to deny UDP traffic. deny udp (for Extended IP ACLs) To drop user datagram protocol (UDP) packets meeting the filter criteria, configure a filter.
Related Commands deny — assigns a filter to deny IP traffic. deny tcp — assigns a filter to deny TCP traffic. deny arp (for Extended MAC ACLs) Configure an egress filter that drops ARP packets on egress ACL supported line cards. (For more information, refer to your line card documentation).
packet count for that new interval commences from zero. If ACL logging was stopped previously because the configured threshold is exceeded, it is re-enabled for this new interval. If ACL logging is stopped because the configured threshold is exceeded, it is re-enabled after the logging interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs.
The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information CONFIGURATION-EXTENDED-ACCESS-LIST Version 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. Version 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
the generation of ACL logs is terminated with the seq, permit, or deny commands. The threshold range is from 1 to 100. Defaults interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The time interval range is from 1 to 10 minutes. monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface.
To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {any | mac-source-address mac-source-address-mask} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
Related Commands permit — configures a MAC address filter to pass packets. seq — configures a MAC address filter with a specified sequence number. deny (for Extended MAC ACLs) To drop packets that match the filter criteria, configure a filter.
Usage Information When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero. If ACL logging was stopped previously because the configured threshold is exceeded, it is re-enabled for this new interval.
Defaults By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information CONFIGURATION-STANDARD-ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.
• Parameters Defaults Use the {destination-mac-address mac-address-mask | any} vlan vlan-id {ipaddress | any | opcode code-number} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated with the seq, permit, or deny commands.
permit ether-type (for Extended MAC ACLs) Configure a filter that allows traffic with specified types of Ethernet packets. This command is supported only on 12-port GE line cards with SFP optics. For specifications, refer to your line card documentation.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Usage Information When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero. If ACL logging was stopped previously because the configured threshold is exceeded, it is re-enabled for this new interval.
The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information CONFIGURATION-EXTENDED-ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3.0.0 Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms.
• Parameters Defaults Use the no deny {source mask | any | host ip-address} {destination mask | any | host ip-address} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated with the seq, permit, or deny commands. The threshold range is from 1 to 100.
Related Commands ip access-list extended — creates an extended ACL. permit tcp — assigns a permit filter for TCP packets. permit udp — assigns a permit filter for UDP packets. permit (for Standard MAC ACLs) To forward packets from a specific source MAC address, configure a filter.
If ACL logging is stopped because the configured threshold is exceeded, it is re-enabled after the logging interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs. You can configure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces.
Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
the generation of ACL logs is terminated with the seq, permit, or deny commands. The threshold range is from 1 to 100. Defaults interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The interval range is from 1 to 10 minutes. monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface.
seq arp (for Extended MAC ACLs) Configure an egress filter with a sequence number that filters ARP packets meeting this criteria. This command is supported only on 12-port GE line cards with SFP optics. For specifications, refer to your line card documentation. NOTE: Only the options that have been newly introduced in Release 9.3(0.0) and Release 9.4(0.0) are described here.
that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces. You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction.
Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, Z9000, and MXL 10/40GbE Switch IO Module platforms. 9.3.0.0 Added support for logging of ACLs on the S4810, S4820T, Z9000, and MXL 10/40GbE Switch IO Module platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled.
To delete a filter, use the no seq sequence-number command. Parameters Defaults log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminate with the seq, permit, or deny commands. The threshold range is from 1 to 100.
permit udp (for IPv6 ACLs) Configure a filter to pass UDP packets meeting the filter criteria. Syntax permit udp {source address mask | any | host ipv6-address} [operator port [port]] {destination address | any | host ipv6-address} [operator port [port]] [count [byte]] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Usage Information Version Description 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information ACCESS-LIST Version Description 9.7(0.
• Parameters Defaults Use the no permit {ipv6-protocol-number | icmp | ipv6 | tcp | udp} command log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated with the seq, permit, or deny commands. The threshold range is from 1 to 100.
deny udp (for IPv6 ACLs) Configure a filter to drop user datagram protocol (UDP) packets meeting the filter criteria.
You can configure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces. You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode.
Usage Information Version Description 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
Defaults interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. You can enter an interval in the range of 1-10 minutes. monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
Parameters Defaults • Use the no seq sequence-number command syntax if you know the filter’s sequence number • Use the no deny {ipv6-protocol-number | icmp | ipv6 | tcp | udp} command log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated.
forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG).
8 Access Control List (ACL) VLAN Groups and Content Addressable Memory (CAM) This chapter describes the access control list (ACL) virtual local area network (VLAN) group and content addressable memory (CAM) enhancements. member vlan Add VLAN members to an ACL VLAN group. Syntax member vlan {VLAN-range} Parameters VLAN-range Enter the member VLANs using comma-separated VLAN IDs, a range of VLAN IDs, a single VLAN ID, or a combination.
Parameters group-name Enter the name of the ACL VLAN group where you want the egress IP ACLs applied, up to 140 characters. out Enter the keyword out to apply the ACL to outgoing traffic. implicit-permit Enter the keyword implicit-permit to change the default action of the ACL from implicit-deny to implicit-permit (that is, if the traffic does not match the filters in the ACL, the traffic is permitted instead of dropped).
Vlan Members Test 1-100 - test - The following sample output is displayed when using the show acl-vlan-group group-name option. NOTE: The access list name is truncated. Dell#show acl-vlan-group TestGroupSeventeenTwenty Group Name Egress IP Acl Ingress IP Acl Acl Vlan Members Test test 1-100 Ingress IPV6 The following sample output shows the line-by-line style display when using the show acl-vlan-group detail option.
Example Field Description VlanOpenFlow Number of FP blocks for VLAN open flow operations. VlanIscsi Number of FP blocks for VLAN internet small computer system interface (iSCSI) counters. VlanHp Number of FP blocks for VLAN high performance processes. VlanFcoe Number of FP blocks for VLAN Fiber Channel over Ethernet (FCoE) operations. VlanAclOpt Number of FP blocks for ACL VLAN optimzation feature.
feature is enhanced. A total of four VACP groups are present, of which two are for fixed groups and the other two are for dynamic groups. Out of the total of two dynamic groups, you can allocate zero, one, or two flow processor (FP) blocks to iSCSI Counters, OpenFlow and ACL Optimization. You can configure only two of these features at a point in time. show cam-usage View the amount of CAM space available, used, and remaining in each partition (including IPv4Flow and Layer 2 ACL sub-partitions).
Example 1: Output of Dell#show cam-usage | Total CAM | Used CAM |Available the show cam-usage Linecard|Portpipe| CAM Partition CAM Command ========|========|=================|=============|=============| ============== 1 | 0 | IN-L2 ACL | 1008 | 320 | 688 | | IN-L2 FIB | 32768 | 1132 | 31636 | | IN-L3 ACL | 12288 | 2 | 12286 | | IN-L3 FIB | 262141 | 14 | 262127 | | IN-L3-SysFlow | 2878 | 45 | 2833 | | IN-L3-TrcList | 1024 | 0 | 1024 | | IN-L3-McastFib | 9215 | 0 | 9215 | | IN-L3-Qos | 8192 | 0 | 8192 | | IN
16384 11 8189 196606 2878 1024 9215 8192 1024 Example 4: Output of the show camusage switch Command | 1 | IN-L3 ACL | 8192 | 3 | | | IN-L3 FIB | 196607 | 1 | | | IN-L3-SysFlow | 2878 | 0 | | | IN-L3-TrcList | 1024 | 0 | | | IN-L3-McastFib | 9215 | 0 | | | IN-L3-Qos | 8192 | 0 | | | IN-L3-PBR | 1024 | 0 | | | OUT-L3 ACL | 16384 | 0 | 16384 Dell#show cam-usage switch Linecard|Portpipe| CAM Partition | Total CAM | Used CAM |Available CAM ========|====
Examples The following sample output shows the line-by-line style display when using the show running-config acl-vlan-group option. Note that no group or access list names are truncated Dell#show running-config acl-vlan-group ! acl-vlan-group Test member vlan 1-100 ip access-group test in Dell#show running-config acl-vlan-group ! acl-vlan-group Test member vlan 1-100 ip access-group test in Test acl-vlan-group Create an ACL VLAN group.
show acl-vlan-group detail Display all the ACL VLAN Groups or display a specific ACL VLAN Group by name. To display the names in their entirety, the output displays in a line-by-line format. Syntax show acl-vlan-group detail Parameters detail Display information in a line-by-line format to display the names in their entirety. Without the detail option, the output is displayed in a table style and information may be truncated.
Usage Information Enter a description for each ACL VLAN group that you create for effective and streamlined administrative and logging purposes.
9 Bidirectional Forwarding Detection (BFD) Bidirectional forwarding detection (BFD) is a detection protocol that provides fast forwarding path failure detection.
ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Introduced BFD for VRRP and OSPFv3 on Z9000, S4810, and S4820T. 9.0.0.0 Introduced BFD for BGP on the Z9000. 8.3.19.
Re-enable BFD using the no bfd disable command. Defaults BFD is disabled by default. Command Modes VRRP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.2(0.2) Introduced on S4810. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.2.1.
bfd enable (Interface) Enable BFD on an interface. S4820T Syntax bfd enable Defaults BFD is enabled on all interfaces when you enable BFD from CONFIGURATION mode. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.
• Passive — The passive system does not initiate a session. It only responds to a request for session initialization from the active system. The default is Active. Defaults Refer to Parameters. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.
Related Commands Version Description 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series. 7.5.1.0 Added support for VLAN and port-channel interfaces on the E-Series. show bfd neighbors — displays the BFD neighbor information on all interfaces or a specified interface. bfd protocol-liveness Enable the BFD protocol liveness feature. S4820T Syntax bfd protocol-liveness Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
To disable BFD for all neighbors configured through static routes, use the no ip route bfd [interval interval min_rx min_rx multiplier value role {active | passive}] command. Parameters interval milliseconds (OPTIONAL) Enter the keywords interval to specify non-default BFD session parameters beginning with the transmission interval. The range is from 50 to 1000. The default is 100.
Parameters disable (OPTIONAL) Enter the keyword disable to disable BFD on this interface. interval milliseconds (OPTIONAL) Enter the keyword interval to specify non-default BFD session parameters beginning with the transmission interval. The range is from 50 to 1000. The default is 100. min_rx milliseconds Enter the keywords min_rx to specify the minimum rate at which the local system receives control packets from the remote system. The range is from 50 to 100. The default is 100.
To remove all BFD sessions with IS-IS neighbors discovered on this interface, use the no isis bfd allneighbors [disable | [interval interval min_rx min_rx multiplier value role {active | passive}]] command. Parameters disable (OPTIONAL) Enter the keyword disable to disable BFD on this interface. interval milliseconds (OPTIONAL) Enter the keywords interval to specify non-default BFD session parameters beginning with the transmission interval. The range is from 50 to 1000. The default is 100.
neighbor bfd Explicitly enable a BFD session with a BGP neighbor or a BGP peer group. S4820T Syntax Parameters neighbor {ip-address | peer-group-name} bfd ip-address Enter the IP address of the BGP neighbor that you want to explicitly enable for BFD sessions in dotted decimal format (A.B.C.D). peer-group-name Enter the name of the peer group that you want to explicitly enable for BFD sessions. Defaults none Command Modes ROUTER BGP Command History This guide is platform-specific.
neighbor bfd disable Explicitly disable a BFD session with a BGP neighbor or a BGP peer group. S4820T Syntax neighbor {ip-address | peer-group-name} bfd disable Parameters ip-address Enter the IP address of the BGP neighbor that you want to explicitly disable for BFD sessions in dotted decimal format (A.B.C.D). peer-group-name Enter the name of the peer group that you want to explicitly disable for BFD sessions.
show bfd neighbors Display BFD neighbor information on all interfaces or a specified interface. S4820T Syntax Parameters show bfd neighbors interface [detail] interface detail Defaults Command Modes Command History Enter one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
LocalAddr * 10.1.3.2 Example (Detail) RemoteAddr 10.1.3.1 Interface State Rx-int Tx-int Mult Clients Te 1/3 Up 300 250 3 C Dell#show bfd neighbors detail Session Discriminator: 1 Neighbor Discriminator: 1 Local Addr: 10.1.3.2 Local MAC Addr: 00:01:e8:02:15:0e Remote Addr: 10.1.3.
Related Commands Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series. 7.5.1.0 Added support for VLAN and port-channel interfaces on the E-Series. 7.4.1.0 Introduced on the E-Series. show bfd neighbors — displays the BFD neighbor information on all interfaces or a specified interface.
10 Border Gateway Protocol BGP is an external gateway protocol that transmits interdomain routing information within and between autonomous systems (AS). BGP version 4 (BGPv4) supports classless inter-domain routing (CIDR) and the aggregation of routes and AS paths. Basically, two routers (called neighbors or peers) exchange information including full routing tables and periodically sent messages to update those routing tables. BGP is supported in Dell Networking OS version 8.3.19.
NOTE: Use this attribute to start a BGP instance corresponding to either a specific address family in a default VRF or an IPv4 address family in a nondefault VRF. ipv6 unicast Enter the keyword ipv6 followed by the keyword unicast to enable BGPv6 mode. vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to install the IPv6 route in that VRF. NOTE: It will not be possible to enable VRF mode for IPv6 unicast without configuring the corresponding IPv4 unicast mode for the same VRF.
AS_SET includes AS_PATH and community information from the routes included in the aggregated route. Defaults attribute-map mapname (OPTIONAL) Enter the keywords attribute-map then the name of a configured route map to modify attributes of the aggregate, excluding AS_PATH and NEXT_HOP attributes. summary-only (OPTIONAL) Enter the keyword summary-only to advertise only the aggregate address. Specific routes are not advertised.
When an aggregate address is denied using a peer's outbound route-map, individual routes suppressed by the aggregate address are advertised to that peer. The attribute-map corresponding to an aggregate address is applied during the outbound update creation time; hence the value set in that attribute-map will not be shown in the output of the show ip bgp aggregate route command.
Defaults both Enter the keyword both to indicate that the system sends and accepts multiple paths from peers. path-count Enter the number paths supported. The range is from 2 to 64. Disabled Command Modes Command History • ROUTER BGP • ROUTER BGP-address-family This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Version Description 8.3.1.0 Introduced the dynamic application of AS notation changes. 8.2.1.0 Introduced. Before enabling this feature, enable the enable bgp four-octet-as-supportcommand. If you disable the four-octect-support command after using dot or dot+ format, the AS numbers revert to asplain text. When you apply an asnotation, it is reflected in the running-configuration. If you change the notation type, the running-config updates dynamically and the new notation shows.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. If you enable this command, use the clear ip bgp * command to recompute the best path. bgp bestpath as-path multipath-relax Include prefixes received from different AS paths during multipath calculation.
To disable MED comparison on BGP confederation paths, enter the no bgp bestpath med confed command. Defaults Disabled Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Usage Information Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 6.3.1.0 Introduced The MED is a 4-byte unsigned integer value and the default behavior is to assume a missing MED as 4294967295. This command causes a missing MED to be treated as 0. During path selection, paths with a lower MED are preferred over paths with a higher MED. bgp bestpath router-id ignore Do not compare router-id information for external paths during best path selection.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.
Usage Information Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. When a BGP cluster contains only one route reflector, the cluster ID is the route reflector’s router ID. For redundancy, a BGP cluster may contain two or more route reflectors. Assign a cluster ID with the bgp cluster-id command. Without a cluster ID, the route reflector cannot recognize route updates from the other route reflectors within the cluster.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. Added support for the 4-byte format To accept 4-byte formats before entering a 4-byte AS number, configure your system. All the routers in the Confederation must be 4 byte or 2 byte identified routers. You cannot mix them. The autonomous systems configured in this command are visible to the EBGP neighbors. Each autonomous system is fully meshed and contains a few connections to other autonomous systems.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Added support for the 4-byte format. All the routers in the Confederation must be 4 byte or 2 byte identified routers. You cannot mix them. The autonomous systems configured in this command are visible to the EBGP neighbors.
route-map mapname (OPTIONAL) Enter the keyword route-map then the name of a configured route map. Only match commands in the configured route map are supported. Defaults Command Modes Command History Disabled. • ROUTER BGP • ROUTER BGP-address-family This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.
This command must be performed on the router which is attaching link bandwidth to prefixes (typically a border router) as well as the router which is expected to load share traffic proportional to the bandwidth of the external links. bgp enforce-first-as Disable (or enable) enforce-first-as check for updates received from EBGP peers. S4820T Syntax bgp enforce-first-as To turn off the default, use the no bgp enforce-first-as command.
bgp fast-external-fallover Enable the fast external fallover feature, which immediately resets the BGP session if a link to a directly connected external peer fails. S4820T Syntax bgp fast-external-fallover To disable fast external fallover, use the no bgp fast-external-fallover command. Defaults Enabled Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Routers supporting 4-byte ASNs advertise that function in the OPEN message. The behavior of a 4-byte router is slightly different depending on whether it is speaking to a 2-byte router or a 4-byte router.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. This feature is advertised to BGP neighbors through a capability advertisement. In Receiver Only mode, BGP saves the advertised routes of peers that support this capability when they restart.
Deterministic mode (no bgp non-deterministic-med), Dell Networking OS compares MED between adjacent paths within an AS group because all paths in the AS group are from the same AS. When you change the path selection from Deterministic to Non-Deterministic, the path selection for the existing paths remains Deterministic until you enter the clear ip bgp command to clear existing paths. bgp recursive-bgp-next-hop Enable next-hop resolution through other routes learned by BGP.
To re-enable optimization engine, use the no bgp regex-eval-optz-disable command. Defaults Enabled Command Modes ROUTER BGP (conf-router_bgp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000.
bgp router-id Assign a user-given ID to a BGP router. S4820T Syntax bgp router-id ip-address To delete a user-assigned IP address, use the no bgp router-id command. Parameters ip-address Enter an IP address in dotted decimal format to reset only that BGP neighbor. Defaults The router ID is the highest IP address of the Loopback interface or, if no Loopback interfaces are configured, the highest IP address of a physical interface on the router.
NOTE: Use this attribute to clear a BGP instance corresponding to either a specific address family in a default VRF or an IPv4 address family in a a non-default VRF. * Enter an asterisk ( * ) to reset all BGP sessions. <1-4294967295> Enter <1-4294967295> to clear peers with the AS number. <0.1-65535.65535> Enter <0.1-65535.65535> to clear peers with the AS number in dot format. A.B.C.D Enter the BGP neighbor address in the A.B.C.D format to clear.
Related Commands Version Description 6.5.1.0 Expanded to include the as-number option. bgp recursive-bgp-next-hop — disables next-hop resolution through other routes learned by the BGP. clear ip bgp dampening Clear information on route dampening and return the suppressed route to the Active state.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. After you enter this command, the software deletes the history routes and returns the suppressed routes to the Active state. The clear ip bgp dampening command does not clear the history paths. clear ip bgp flap-statistics Clear BGP flap statistics, which includes number of flaps and the time of the last flap.
• ^ = (caret) the beginning of the input string. If you use the caret at the beginning of a sequence or range, it matches on everything BUT the characters specified. • $ = (dollar sign) the end of the output string. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
ipv4 unicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword unicast to reset ipv4 unicast routes. ipv6 unicast (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to reset ipv6 unicast routes. soft (OPTIONAL) Enter the keyword soft to reset soft configuration. in Enter the keyword in to re-configure soft inbound updates. out Enter the keyword out to re-configure soft outbound updates. Command Modes EXEC Privilege Command History This guide is platform-specific.
out (OPTIONAL) Enter the keyword out to view only information on outbound BGP routes. A.B.C.D Enter the IP address of peer in the A.B.C.D format. X:X:X:X::X Enter the IPv6 IP address of peer in the X:X:X:X::X format. dampening Enter the keyword dampening to view BGP dampening. events Enter the keyword events to view BGP protocol events. ipv4 Enter the ipv4 IP address to view the IPV4 route information. ipv6 Enter the ipv6 IP address to view the IPV6 route information.
debug ip bgp updates — views information about BGP updates. show debugging — views enabled debugging operations. debug ip bgp dampening View information on routes being dampened. S4820T Syntax debug ip bgp [vrf vrf-name] [ipv4 {unicast | multicast} | ipv6 unicast] dampening To disable debugging, use the no debug ip bgp dampening command. Parameters vrf vrf-name Enter the keyword vrf followed by the name of the VRF to view information on dampened routes corresponding to that VRF.
debug ip bgp events Display information on local BGP state changes and other BGP events. S4820T Syntax debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-groupname] events [in | out] To disable debugging, use the no debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-group-name] events [in | out] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display BGP state changes corresponding to that VRF. A.B.C.
debug ip bgp keepalives Display information about BGP keepalive messages. S4820T Syntax debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-groupname] keepalives [in | out] To disable debugging, use the no debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-group-name] keepalives [in | out] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display BGP keepalive information corresponding to that VRF. A.B.C.
To disable debugging, use the no debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-group-name] notifications [in | out] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to view neighbor BGP notification information corresponding to that VRF. A.B.C.D (OPTIONAL) Enter the IPv4 address of the neighbor. X:X:X:X::X (OPTIONAL) Enter an IPv6 address.
X:X:X:X::X (OPTIONAL) Enter an IPv6 address. peer-group-name (OPTIONAL) Enter the name of the peer group to disable or enable all routers within the peer group.. Defaults Disabled Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
out (OPTIONAL) Enter the keyword out to view only BGP updates sent to neighbors. prefix-list prefix-listname (OPTIONAL) Enter the keyword prefix-list then the name of an established prefix list. If the prefix list is not configured, the default is permit (to allow all routes). ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. peer-group-name (OPTIONAL) Enter the name of the peer group to disable or enable all routers within the peer group.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Usage Information The default-metric command in BGP sets the value of the BGP MULTI_EXIT_DISC (MED) attribute for redistributed routes only. Related Commands bgp always-compare-med — enables comparison of all BGP MED attributes.
Related Commands Version Description pre-7.7.1.0 Introduced. router bgp — enters ROUTER mode on the switch. deny bandwidth Enables you to specify link band width extended-community attribute as the matching criteria to deny incoming or outgoing traffic. Syntax deny bandwidth To disable this setting, enter the no deny bandwidth command. Parameters bandwidth Enter the keyword bandwidth to specify extended-community attribute as the matching criteria for denying traffic.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Support from 2 to 64 paths on the S4810. Command syntax changed to maxpath (was maximum-paths). 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. If you enable this command, use the clear ip bgp * command to recompute the best path.
Usage Information By default, when you create a neighbor/peer group configuration in the Router BGP context, this enables IPv4/Unicast AFI/SAFI. When you use activate in the new context, the neighbor/peer group enables for AFI/SAFI. It is not possible to de-activate a peer from the IPv4 unicast address family. neighbor add-path This command allows the specified neighbor/peer group to send/receive multiple path advertisements.
To return to the default value, use the no neighbor {ip-address | peer-group-name} advertisement-interval command. Parameters Defaults ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group to set the advertisement interval for all routers in the peer group. seconds Enter a number as the time interval, in seconds, between BGP advertisements. The range is from 0 to 600 seconds.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.
Version Description 7.7.1.0 Introduced on the C-Series. Usage Information You cannot set this configuration for a peer that is associated with a peer group. Similarly, you cannot associate a peer to a peer group if that peer is already configured with these settings. Related Commands bgp four-octet-as-support — enables 4-byte support for the BGP process. neighbor default-originate Inject the default route to a BGP peer or neighbor.
Route-map configuration on a BGP peer or peer group works only when the LOC-RIB contains at least one route. When you apply a default route to a BGP peer or peer group using the neighbor default-originate command, changes to the configured default route-map are applied to the BGP peer or peer group only after a delay of 15 seconds. As a result, you must wait for a period of 15 seconds before manually resetting BGP using the clear ip bgp command.
neighbor distribute-list Distribute BGP information via an established prefix list. S4820T Syntax neighbor {ip-address | peer-group-name} distribute-list prefix-list-name {in | out} To delete a neighbor distribution list, use the no neighbor {ip-address | peer-group-name} distribute-list prefix-list-name {in | out} command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format.
neighbor ebgp-multihop Attempt and accept BGP connections to external peers on networks that are not directly connected. S4820T Syntax neighbor {ip-address | peer-group-name} ebgp-multihop [ttl] To disallow and disconnect connections, use the no neighbor {ip-address | peer-groupname} ebgp-multihop command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group.
Defaults Disabled. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Defaults threshold = 75 Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Parameters ip-address Enter the IP address of the router to be included in the peer group. peer-group-name Enter the name of a configured peer group. dmzlink-bw Enter the keyword dmzlink-bw to attach a link bandwidth to received routes. NOTE: If dmzlink-bw is configured for a peer, in order for the BGP peer to advertise the prefixes with dmzlink-bw attached to it, you must reset the the peer or peer-group using the clear ip bgp session command. Defaults Not configured.
neighbor peer-group (creating group) — creates a peer group. show ip bgp peer-group — views BGP peers. show ip bgp neighbors — views BGP neighbors configurations. neighbor peer-group (creating group) Allows you to create a peer group and assign it a name. S4820T Syntax neighbor peer-group-name peer-group To delete a peer group, use the no neighbor peer-group-name peer-group command. Parameters peer-group-name Enter a text string up to 16 characters long as the name of the peer group.
To delete a passive peer-group, use the no neighbor peer-group-name peer-group passive command. Parameters peer-group-name Enter a text string up to 16 characters long as the name of the peer group. limit (Optional) Enter the keyword limit to constrain the numbers of sessions for this peer-group. The range is from 2 to 256. The default is 256. Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific.
peer-group-name Enter the name of the peer group to enter the remote AS into routing tables of all routers within the peer group. number Enter a number of the AS. The range is from 0 to 65535 (2 byte) or from 1 to 4294967295 (4 byte). Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
NOTE: This command sends routes to peers only if an outbound policy is configured and if there is a change in the existing outbound policy. Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
standard (OPTIONAL) Enter the keyword standard to send standard community attribute. Defaults Not configured and COMMUNITY attributes are not sent to neighbors. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version 9.0.2.0 Introduced on the S6000.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Peers that are enabled within a peer group are disabled when their peer group is disabled. The neighbor shutdown command terminates all BGP sessions on the BGP neighbor or BGP peer group.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.4.1.0 Introduced. This command enables soft-reconfiguration for the BGP neighbor specified. BGP stores all the updates the neighbor receives but does not reset the peer-session. You cannot set this configuration for a peer that is associated with a peer group.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Timer values configured with the neighbor timers command override the timer values configured with any other command.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Loopback interfaces are up constantly and the BGP session may need one interface constantly up to stabilize the session. The neighbor update-source command is not necessary for directly connected internal BGP sessions. Neighbors are sorted according to the source and destination ip addresses.
NOTE: In the Dell Networking OS best-path selection process, the path with the highest weight value is preferred. If you configure the set weight command in a route map applied to this neighbor, the weight set in that command overrides the weight set in the neighbor weight command. Related Commands set weight — assigns a weight to all paths meeting the route map criteria. network Specify the networks for the BGP process and enter them in the BGP routing table.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Dell Networking OS software resolves the network address the network command configures with the routes in the main routing table to ensure that the networks are reachable using non-BGP routes and nondefault routes.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Although Dell Networking OS does not generate a route due to the backdoor config, there is an option for injecting/sourcing a local route in the presence of network backdoor config on a learned route.
route-map mapname (OPTIONAL) Enter the keyword route-map then the name of an established route map. Only the following ROUTE-MAP mode commands are supported: • match ip address • set community • set local-preference • set metric • set next-hop • set origin • set weight If the route map is not configured, the default is deny (to drop all routes). Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific.
When a combination of locally originated and peer originated routes occurs, both these routes will exist in the RTM. However, only the best route is kept active in the RTM and the remaining route is rendered inactive. It is possible to keep only one locally originated route in the BGP database. Network command has preference over the re-distributed routes. When the locally originated route is no longer present in the database the other route is automatically installed.
Usage Information You can use the redistribute command to advertise the IGP cost as the MED on redistributed routes. When you set the route-map with metric-type internal and apply outbound to an EBGP peer/peer-group, the advertised routes corresponding to those peer/peer-groups have the IGP cost set as MED. When you enter the redistribute isis process-id command without any other parameters, Dell Networking OS redistributes all OSPF internal routes, external type 1 routes, and external type 2 routes.
set extcommunity bandwidth Enables you to set extended community bandwidth. Syntax set extcommunity bandwidth To disable extended community bandwidth, enter the no set extcommunity bandwidth command. Parameters bandwidth Defaults N/A Command Modes ROUTER MAP Command History Usage Information Enter the keyword bandwidth to enable extended community bandwidth. The range is from 0 to 102400. Version Description 9.7(0.0) Introduced on the S-Series.
Example Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Introduced. Dell(conf-router_bgp)#show capture bgp-pdu neighbor 20.20.20.2 Incoming packet capture enabled for BGP neighbor 20.20.20.
Example Version Description 7.7.1.0 Introduced on the C-Series. Dell(conf-router_bgp)#show config ! router bgp 100 network 1.1.11.1/32 network 1.1.12.1/32 network 1.1.13.1/32 neighbor 10.1.1.2 remote-as 200 neighbor 10.1.1.2 no shutdown show ip bgp View the current BGP IPv4 routing table for the system.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. When you enable the bgp non-deterministic-med command, the show ip bgp command output for a BGP route does not list the INACTIVE reason. In BGP, this command displays the exact reason why the route is discarded. The following describes the show ip bgp command shown in the following example.
neighbor maximum-prefix — controls the number of network prefixes received. show ip bgp cluster-list View BGP neighbors in a specific cluster. S4820T Syntax show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] cluster-list [cluster-id] Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to view cluster information of BGP neighbors corresponding to that VRF.
Example Field Description Next Hop Displays the next hop address of the BGP router. If 0.0.0.0 is listed in this column, then local routes exist in the routing table. Metric Displays the BGP route’s metric, if assigned. LocPrf Displays the BGP LOCAL_PREF attribute for the route. Weight Displays the route’s weight. Path Lists all the ASs the route passed through to reach the destination network.
ipv6 unicast (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to view information related only to ipv6 unicast routes. community-number Enter the community number in AA:NN format where AA is the AS number (2 bytes) and NN is a value specific to that autonomous system. You can specify up to eight community numbers to view information on those community groups. local-AS Enter the keywords local-AS to view all routes with the COMMUNITY attribute of NO_EXPORT_SUBCONFED.
Usage Information To view the total number of COMMUNITY attributes found, use the show ip bgp summary command. The text line above the route table states the number of COMMUNITY attributes found. The show ip bgp community command without any parameters lists BGP routes with at least one BGP community attribute and the output is the same as for the show ip bgp command output. The following describes the show ip bgp community command shown in the following example.
show ip bgp community-list View routes that a specific community list affects. S4820T Syntax show ip bgp [vrf vrf-name] [ipv4 {unicast | multicast} | ipv6 unicast] community-list community-list-name [exact-match] Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keywords vrf and then the name of the VRF to view routes affected by a specific community list corresponding to that VRF.
Example Field Description Network Displays the destination network prefix of each BGP route. Next Hop Displays the next hop address of the BGP router. If 0.0.0.0 is listed in this column, then local routes exist in the routing table. Metric Displays the BGP route’s metric, if assigned. LocPrf Displays the BGP LOCAL_PREF attribute for the route. Weight Displays the route’s weight. Path Lists all the ASs the route passed through to reach the destination network.
ipv6 unicast Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to view information related only to ipv6 unicast routes. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Network d From 55.0.0.0/24 172.16.0.2 Reuse Path 00:36:23 200 Dell# show ip bgp dampened-paths View BGP routes that are dampened (non-active). S4820T Syntax Parameters Command Modes Command History show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] dampened-paths vrf vrf-name (OPTIONAL) Enter the keywords vrf and then the name of the VRF to view routes that are affected by a specific community list corresponding to that VRF.
The history paths that the show ip bgp command displays contain only the prefix and the next-hop information. The next-hop information shows the ip address of the neighbor. It does not show the actual next-hop details. The following describes the show ip bgp damp command shown in the following example. Example Field Description Network Displays the network ID to which the route is dampened. From Displays the IP address of the neighbor advertising the dampened route.
Example Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Introduced.
NdAFWPtrP 0 NdAFWLen 0 : NdAfNH : NdAFRedRttP 0x41a0d400 : NdRecCtxAdd 1101110868 NdRedCtxAddrLen 255 : NdAfRedMkrP 0x41a19e88 : AFAggRttP 0x41a0d600 : AfAggCtxAddr 1101111028 : AfAggrCtxAddrLen 255 AfNumAggrPfx 0 : AfNumAggrASSet 0 : AfNumSuppmap 0 : AfNumAggrValidPfx 0 : AfMPathRttP 0x41a0d700 MpathCtxAddr 1101111140 : MpathCtxAddrlen 255 : AfEorSet 0x41a19f98 : NumDfrdPfx 0 AfActPeerHd 0x41a1a3a4 : AfExtDist 1101112312 : AfIntDist 200 : AfLocDist 200 AfNumRRc 0 : AfRR 0 : AfNetRttP 0x41a0d300 : AfNetCtxA
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. To view the total number of COMMUNITY attributes found, use the show ip bgp summary command. The text line above the route table states the number of COMMUNITY attributes found.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.
Path source: I - internal, a - aggregate, c - confed-external, r redistributed n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete *> 400 *> 500 Network 55.0.0.0/24 500 600 i 66.0.0.0/24 i Next Hop 172.16.0.2 Metric LocPrf Weight Path 0 200 172.16.0.2 0 200 show ip bgp flap-statistics View flap statistics on BGP routes.
• Command Modes Command History • EXEC • EXEC Privilege $ = (dollar sign) the end of the output string. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.
00:00:00 200 i Dell#*>n 66.66.77.77/32 0.0.0.0 0 32768 i show ip bgp inconsistent-as View routes with inconsistent originating autonomous system (AS) numbers; that is, prefixes that are announced from the same neighbor AS but with a different AS-Path.
Example Field Description Path Lists all the ASs the route passed through to reach the destination network. Dell>show ip bgp inconsistent-as BGP table version is 280852, local router ID is 10.1.2.100 Status codes: s suppressed, d damped, h history, * valid, > best Path source: I - internal, c - confed-external, r - redistributed, n network Origin codes: i - IGP, e - EGP, ? - incomplete Network Next * 3.0.0.0/8 * * *> *> 3.18.135.0/24 * * * *> 4.0.0.0/8 * * * * 6.0.0.0/20 * *> * * 9.2.0.
statistics | routes | {received-routes [network [network-mask]]} | {deniedroutes [network [network-mask]]}] Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to view information exchanged by BGP neighbors corresponding to that VRF. NOTE: You can use this attribute to view information exchanged by BGP neighbors that correspond to either a default or a non-default VRF.
Usage Information Version Description 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Added the add-path option to the S4810. Output on the S4810 shows the ADDPATH parameters. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Added the detail option. Output now displays the default MED value. 7.2.1.
Example The Lines Beginning with: Description Sent messages The line displays the number of BGP messages sent, the number of notifications (error messages), and the number of messages waiting in a queue for processing. Received updates This line displays the number of BGP updates received and sent. Soft reconfiguration This line indicates that soft reconfiguration inbound is configured. Minimum time Displays the minimum time, in seconds, between advertisements.
For address family: IPv4 Unicast BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 InQ : Added 0, Replaced 0, Withdrawn 0 OutQ : Added 0, Withdrawn 0 Allow local AS number 0 times in AS-PATH attribute Prefixes accepted 2, withdrawn 15 by peer, martian prefixes ignored 0 Prefixes advertised 0, denied 0, withdrawn 0 from peer Connections established 1; dropped 0 Last reset never Local host: 172.16.0.1, Local port: 58145 Foreign host: 172.16.0.
Example Field Description Next-hop Displays the next-hop IP address. Via Displays the IP address and interface used to reach the next hop. RefCount Displays the number of BGP routes using this next hop. Cost Displays the cost associated with using this next hop. Flaps Displays the number of times the next hop has flapped. Time Elapsed Displays the time elapsed since the next hop was learned. If the route is down, this field displays time elapsed since the route went down.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Added support for VRF for the S4810, S4820T, and S6000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf to view all unique COMMUNITY numbers in the BGP database corresponding to that VRF. NOTE: You can use this attribute to view information on unique COMMUNITY numbers in a BGP database that correspond to either a default or a non-default VRF. Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show ip bgp peer-group Allows you to view information on the BGP peers in a peer group. S4820T Syntax show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] peer-group [peer-group-name [detail | summary]] Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf to view information on BGP peers in a peer group corresponding to that VRF. NOTE: You can use this attribute to view information on BGP peers in a peer group that correspond to either a default or a non-default VRF.
Usage Information Example Version Description 7.7.1.0 Introduced on the C-Series. The following describes the show ip bgp peer-group command shown in the following example. Line beginning with: Description Peer-group Displays the peer group’s name. Administratively shut Displays the peer group’s status if the peer group is not enabled. If you enable the peer group, this line is not displayed. BGP version Displays the BGP version supported.
NOTE: You can use this attribute to view the subset of BGP routing tables that match the regular expression that is specified on either a default or a non-default VRF. regular-expression [character] Enter a regular expression then use one or a combination of the following characters to match: • . = (period) any single character (including a white space). • * = (asterisk) the sequences in a pattern (zero or more sequences). • + = (plus) the sequences in a pattern (one or more sequences).
Example Field Description Metric Displays the BGP router’s metric, if assigned. LocPrf Displays the BGP LOCAL_PREF attribute for the route. Weight Displays the route’s weight Path Lists all the AS paths the route passed through to reach the destination network. Dell#show ip bgp regexp ^200 BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. In BGP, route attributes are maintained at different locations. When attributes that correspond to multiple routes change, then attribute counts that the show ip bgp summary command displays are calculated as summations of attributes corresponding to all the associated routes.
Field Description TblVer Displays the version of the BGP table that was sent to that neighbor. InQ Displays the number of messages from that neighbor waiting to be processed. OutQ Displays the number of messages waiting to be sent to that neighbor. If a number appears in parentheses, the number represents the number of messages waiting to be sent to the peer group. Up/Down Displays the amount of time that the neighbor is in the Established stage.
show running-config bgp To display the current BGP configuration, use this feature. S4820T Syntax show running-config bgp Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
holdtime Enter a number for the time interval, in seconds, between the last keepalive message and declaring the router dead. The range is from 3 to 65535. The default is 180 seconds. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.
Parameters vrf vrf-name Enter the keyword vrf followed by the name of the VRF to view information on dampened routes corresponding to that VRF. ipv4 multicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword multicast to view dampened-route information related only to ipv4 multicast routes. ipv4 unicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword multicast to view dampened-route information related only to ipv4 unicast routes.
• internal-distance = 200 • local-distance = 200 Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version 8.3.19.0 Introduced on the S4820T. Version 8.3.7.0 Introduced on the S4810. Version 7.8.1.0 Introduced on the S-Series. Version 7.7.1.0 Introduced on the C-Series.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series.
BGP Extended Communities (RFC 4360) BGP Extended Communities, as defined in RFC 4360, is an optional transitive BGP attribute. BGP Extended Communities provides two major advantages over Standard Communities: • The range is extended from 4-octet (AA:NN) to 8-octet (Type:Value) to provide enough number communities. • Communities are structured using a new “Type” field (1 or 2-octets), allowing you to provide granular control/filter routing information based on the type of extended communities.
Related Commands • If the rt option comes after soo, without the additive option, rt overrides the communities soo sets. • If the rt with the additive option comes after soo, rt adds the communities soo sets. set extcommunity soo — sets the extended community site-of-origin in the route-map. set extcommunity soo To set extended community site-of-origin in Route Map, use this feature.
show ip bgp ipv4 extcommunity-list To display the IPv4 routes matching the extended community list name, use this feature. Syntax Parameters Defaults Command Modes Command History show ip bgp [ipv4 [multicast | unicast] | ipv6 unicast] extcommunity-list name multicast Enter the keyword multicast to display the multicast route information. unicast Enter the keyword unicast to display the unicast route information.
Extended Communities : RT:1111:4278080 SoO:35:4 SoO:36:50529043 SoO:37:50529044 SoO:38:50529045 SoO:0.0.0.2:33 SoO:506.62106:34 0x0303:254:11223* Dell# show ip bgp paths extcommunity To display all BGP paths having extended community attributes, use this feature. S4820T Syntax show ip bgp paths extcommunity Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
show ip extcommunity-list Display the IP extended community list. S4820T Syntax Parameters Command Modes Command History show ip extcommunity-list [word] word • EXEC • EXEC Privilege Enter the name of the extended community list you want to view. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version 8.
as-number Clear and reapply policies for all neighbors belonging to the AS. The range is from 0 to 65535 (2 Byte), from 1 to 4294967295 (4 Byte), or from 0.1 to 0.65535.65535 (Dotted format). ipv4-neighbor-addr | ipv6-neighboraddr Clear and reapply policies for a neighbor. peer-group name Clear and reapply policies for all BGP routers in the specified peer group. ipv6 unicast Clear and reapply policies for all IPv6 unicast routes. in Reapply only inbound policies.
ipv6 unicast Debug soft reconfiguration for IPv6 unicast routes. Defaults Disabled. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.4.1.
neighbor soft-reconfiguration inbound Enable a BGP soft-reconfiguration and start storing updates for inbound IPv6 unicast routes. S4820T Syntax neighbor {ipv4-address | ipv6-address | peer-group-name} softreconfiguration inbound Parameters ipv4-address | ipv6address Enter the IP address of the neighbor for which you want to start storing inbound routing updates. peer-group-name Enter the name of the peer group for which you want to start storing inbound routing updates. Defaults Disabled.
Parameters ipv6-address prefixlength (OPTIONAL) Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros. summary Display a summary of RPF routes. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant FTOS Command Line Reference Guide.
11 Content Addressable Memory (CAM) Content addressable memory (CAM) commands are supported on the Dell Networking S4820T platform. NOTE: Not all CAM commands are supported on all platforms. Be sure to note the platform when looking for a command. WARNING: If you are using these features for the first time, contact Dell Networking Technical Assistance Center (TAC) for guidance. CAM Profile Commands The CAM profiling feature allows you to partition the CAM to best suit your application.
number] ecfmacl number [nlbclusteracl number] ipv4pbr number }openflow number | fcoe number} [iscsioptacl number] [vrfv4acl number] Parameters default Use the default CAM profile settings and set the CAM as follows: • L2Acl : 6 • IPV4Acl : 4 • IPV6Acl : 0 • IPV4Qos : 2 • L2Qos : 1 • L2PT : 0 • IpMacAcl : 0 • VmanQos : 0 • VmanDualQos : 0 • EcfmAcl : 0 • nlbclusteracl: 0 • FcoeAcl : 0 • iscsiOptAcl : 0 • ipv4pbr : 0 • vrfv4Acl :0 • Openflow : 0 • fedgovacl : 0 l2acl number
NOTE: When you reconfigure CAM allocation, use the nlbclusteracl number command to change the number of NLB ARP entries. The range is from 0 to 2. The default value is 0. At the default value of 0, eight NLB ARP entries are available for use. This platform supports up to 512 CAM entries. Select 1 to configure 256 entries. Select 2 to configure 512 entries.
Usage Information Version Description 9.4.(0.0) Added support for PBR and VRF. 9.2(0.2) Added support for fcoe. 9.1.(0.0) Added support for OpenFlow. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.2 Clarified block information for the S4810. 8.3.10.0 Introduced on the S4810. 8.3.1.0 Added the keywords ecfmacl, vman-qos, and vman-dual-qos. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. cam-optimization Optimize CAM utilization for QoS Entries by minimizing require policy-map CAM space. S4820T Syntax cam-optimization [qos] Parameters qos Optimize CAM usage for QoS. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
show cam-acl Display the details of the CAM profiles on the chassis and all stack units. S4820T Syntax show cam-acl Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
VmanQos : VmanDualQos : EcfmAcl : FcoeAcl : iscsiOptAcl : ipv4pbr : vrfv4Acl : Openflow : fedgovacl : nlbclusteracl: 0 0 0 0 0 0 0 0 0 0 -- stack-unit 1 -Current Settings(in block sizes) 1 block = 128 entries L2Acl : 6 Ipv4Acl : 4 Ipv6Acl : 0 Ipv4Qos : 2 L2Qos : 1 L2PT : 0 IpMacAcl : 0 VmanQos : 0 VmanDualQos : 0 EcfmAcl : 0 FcoeAcl : 0 iscsiOptAcl : 0 ipv4pbr : 0 vrfv4Acl : 0 Openflow : 0 fedgovacl : 0 nlbclusteracl: 0 test cam-usage Verify that enough CAM space is available for the IPv6 ACLs you have c
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced. This command applies to both IPv4 and IPv6 CAM Profiles, but is best used when verifying QoS optimization for IPv6 AC QoS Optimization for IPv6 ACLs does not impact the CAM usage for applying a policy on a single (or the first of several) interfaces. It is most useful when a policy is applied across multiple interfaces; it can reduce the impact to CAM usage acr subsequent interfaces.
Example (S-Series) Dell#test cam-usage service-policy input LauraIn stack-unit all Stack-Unit|Portpipe|CAM Partition|AvailableCAM|EstimatedCAM per Port|Status -----------------------------------------------------------------------0| 0| IPv4Flow| 102| 0|Allowed 0| 0| IPv4Flow| 102| 0|Allowed Dell# ! Dell#test cam-usage service-policy input LauraIn stack-unit 0 port-set 1 Stack-Unit|Portpipe|CAM Partition|Available CAM|EstimatedCAM per Port|Status -------------------------------------------------------------
12 Control Plane Policing (CoPP) The CoPP commands are supported on the Dell Networking S4820T platform. control-plane-cpuqos To manage control-plane traffic, enter control-plane mode and configure the switch. S4820T Syntax control-plane-cpuqos Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters Command Modes Command History Usage Information vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to enable catch-all routes corresponding to that VRF. CONFIGURATION Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S–Series. Use this command to add the IPv4 catch-all route (0.0.0.0/0) in the LPM route forwarding table if it was deleted using the no ip unknown-unicast command previously.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810.
Usage Information Version Description 8.3.8.0 Introduced on the S4810. This command applies the service-policy based on the type of protocol defined in the ACL rules. Create ACL and QoS policies prior to enabling this command. For CoPP, use the keyword cpu-qos when creating qos-policy-input. Related Commands ip access-list extended — creates an extended IP ACL. mac access-list extended — creates an extended MAC ACL. qos-policy-input — creates a QoS input policy map.
-------------Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q10 Q11 ----------1300 300 300 400 2000 300 400 400 400 600 300 300 ----------512 50 50 50 50 50 50 50 50 50 50 50 show ip protocol-queue-mapping Display the queue mapping for each configured protocol. S4820T Syntax show ip protocol-queue-mapping Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific.
Dell# Dell# Dell# show ipv6 protocol-queue-mapping Display the queue mapping for each configured IPv6 protocol. S4820T Syntax show ipv6 protocol-queue-mapping Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.
13 Data Center Bridging (DCB) Data center bridging (DCB) refers to a set of IEEE Ethernet enhancements that provide data centers with a single, robust, converged network to support multiple traffic types, including local area network (LAN), server, and storage traffic. The Dell Networking operating software commands for data center bridging features include 802.1Qbb priority-based flow control (PFC), 802.1Qaz enhanced transmission selection (ETS), and the data center bridging exchange (DCBX) protocol.
Usage Information Version Description 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. By default, iSCSI is enabled on the unit and the flow control is enabled on all of the interfaces. It is also acts as defaults when the link-level flow control is enabled on one or more interfaces. Enables priority flow control or enhance transmission selection on interface.
description Enter a text description of the DCB policy (PFC input or ETS output). Syntax description text To remove the text description, use the no description command. Parameters Defaults text Enter the description of the output policy. The maximum is 32 characters. none Command Modes Command History • DCB INPUT POLICY • DCB OUTPUT POLICY This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information NOTE: Please note that Dell Networking does not recommended to use this command as it has been deprecated in the current 9.4.(0.0) release. A warning message appears when you try to run this command indicating that you have to use the dcb-map commands in the future. By applying a DCB input policy with PFC enabled, you enable PFC operation on ingress port traffic.
dot1p Value in the Incoming Frame Description heading 0 0 1 0 2 0 3 1 4 2 5 3 6 3 7 3 show dcb Displays the data center bridging status, the number of PFC-enabled ports, and the number of PFC-enabled queues. Syntax show dcb [stack-unit unit-number] [port-set port-set-number] Parameters unit-number Enter the DCB unit number. port-set-number Enter the port-set number. Command Modes EXEC Privilege Command History This guide is platform-specific.
Parameters port-type slot/ port[] pfc Enter the port-type slot and port PFC information. {summary | detail} Enter the keyword summary for a summary list of results or enter the keyword detail for a full list of results. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Field Description TLV Tx Status Status of the PFC TLV advertisements: enabled or disabled. PFC Link Delay Link delay (in quanta) used to pause specified priority traffic. Application Priority TLV: FCOE TLV Tx Status Status of FCoE advertisements in application priority TLVs from the local DCBX port: enabled or disabled. Application Priority TLV: SCSI TLV Tx Status Status of ISCSI advertisements in application priority TLVs from the local DCBX port: enabled or disabled.
Remote ISCSI PriorityMap is 0x8 Dell# show interfaces tengigabitethernet 1/4 pfc detail Interface TenGigabitEthernet 1/4 Admin mode is on Admin is enabled Remote is enabled Remote Willing Status is enabled Local is enabled Oper status is recommended PFC DCBX Oper status is Up State Machine Type is Feature TLV Tx Status is enabled PFC Link Delay 45556 pause quanta Application Priority TLV Parameters : -------------------------------------FCOE TLV Tx Status is disabled ISCSI TLV Tx Status is disabled Local FC
4 5 6 0 7 0 0 0 0 0 0 0 0 show stack-unit stack-ports pfc details Displays the PFC configuration applied to ingress traffic on stacked ports, including PFC Operational mode on each unit with the configured priorities, link delay, and number of pause packets sent and received. Syntax show stack-unit {all | stack-unit} stack-ports {all | port-number} pfc details Parameters stack-unit Enter the stack unit. port-number Enter the port number.
bandwidth-percentage Configure the bandwidth percentage allocated to priority traffic in port queues. Syntax bandwidth-percentage percentage To remove the configured bandwidth percentage, use the no bandwidth-percentage command. Parameters percentage (Optional) Enter the bandwidth percentage. The percentage range is from 1 to 100% in units of 1%. Defaults none Command Modes QOS-POLICY-OUT-ETS Command History This guide is platform-specific.
clear ets counters Clear all ETS TLV counters on an interface. Syntax clear ets counters port-type slot/port[] Parameters port-type Enter the keywords port-type then the slot/port information. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Version Description 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. By default, iSCSI is enabled on the unit and the flow control is enabled on all of the interfaces. It is also acts as defaults when the link-level flow control is enabled on one or more interfaces. Enables priority flow control or enhance transmission selection on interface. Related Commands dcb enable — enable priority flow control or enhanced transmission selection on interface.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. By default: • All 802.1p priorities are grouped in priority group 0.
If you configure more than one priority queue as strict priority or more than one priority group as strict priority, the higher numbered priority queue is given preference when scheduling data traffic. You must fully define the priority-group profile with a PGID and priorities before mapping it to a QoS policy because the PGID and priorities are unique keys of the traffic class group (TCG) that define the QoS policy.
• bandwidth-percentage — bandwidth percentage allocated to the priority traffic in port queues. set-pgid Configure the priority-group identifier. Syntax set-pgid value To remove the priority group, use the no set-pgid command. Parameters value Enter the priority group identification. The range is from 0 to 7. Defaults none Command Modes PRIORITY-GROUP Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. dot1p priority traffic on the switch is scheduled to the current queue mapping. dot1p priorities within the same queue must have the same traffic properties and scheduling method.
Example (Summary) Dell#show interface te 1/3 ets de Interface TenGigabitEthernet 1/3 Max Supported TC Groups is 4 Number of Traffic Classes is 8 Admin mode is on Admin Parameters : -----------------Admin is enabled TC-grp Priority# Bandwidth TSA -----------------------------------------------0 1 0,1,2 100% ETS 2 3 0 % SP 3 4,5,6,7 0 % SP 4 5 6 7 Remote Parameters : ------------------Remote is disabled Local Parameters : -----------------Local is enabled TC-grp Priority# Bandwidth TSA -----------------------
6 7 - - Remote Parameters : ------------------Remote is disabled Local Parameters : -----------------Local is enabled TC-grp Priority# Bandwidth TSA -----------------------------------------------0 1 0,1,2 100% ETS 2 3 0 % SP 3 4,5,6,7 0 % SP 4 5 6 7 Oper status is init ETS DCBX Oper status is Down State Machine Type is Asymmetric Conf TLV Tx Status is enabled Reco TLV Tx Status is enabled 0 Input Conf TLV Pkts, 1955 Output Conf TLV Pkts, 0 Error Conf TLV Pkts 0 Input Reco TLV Pkts, 1955 Output Reco TLV
5 0% ETS 6 0% ETS 7 0% ETS Priority# Bandwidth TSA 0 13% ETS 1 13% ETS 2 13% ETS 3 13% ETS 4 12% ETS 5 12% ETS 6 12% ETS 7 12% ETS Oper status is init Conf TLV Tx Status is disabled Traffic Class TLV Tx Status is disabled 0 Input Conf TLV Pkts, 0 Output Conf TLV Pkts, 0 Error Conf TLV Pkts 0T LIVnput Traffic Class TLV Pkts, 0 Output Traffic Class TLV Pkts, 0 Error Traffic Class Pkts Example (Detail) Dell(conf)# show interfaces tengigabitethernet 1/1 ets detail Interface TenGigabitEthernet 1/1 Max Supported
2 13% ETS 3 13% ETS 4 12% ETS 5 12% ETS 6 12% ETS 7 12% ETS Oper status is init Conf TLV Tx Status is disabled Traffic Class TLV Tx Status is disabled 0 Input Conf TLV Pkts, 0 Output Conf TLV Pkts, 0 Error Conf TLV Pkts 0 Input Traffic Class TLV Pkts, 0 Output Traffic Class TLV Pkts, 0 Error Traffic Class TLV Pkts show qos priority-groups Displays the ETS priority groups configured on the switch, including the 802.1p priority classes and ID of each group.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module.
To disable DCBX iSCSI TLV advertisements, use the no advertise dcbx-app-tlv iscsi command. Defaults Enabled Command Modes PROTOCOL LLDP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.
advertise dcbx-tlv On a DCBX port with a manual role, configure the PFC and ETS TLVs advertised to DCBX peers. Syntax advertise dcbx-tlv {ets-conf | ets-reco | pfc} [ets-conf | ets-reco | pfc] [ets-conf | ets-reco | pfc] To remove the advertised ETS TLVs, use the no advertise dcbx-tlv command. Parameters {ets-conf | ets-reco | pfc} Enter the PFC and ETS TLVs advertised, where: • ets-conf: enables the advertisement of ETS configuration TLVs. • ets-reco: enables the advertisement of ETS recommend TLVs.
Parameters config-source | auto-downstream | auto-upstream | manual Enter the DCBX port role, where: • config-source: configures the port to serve as the configuration source on the switch. • auto-upstream: configures the port to receive a peer configuration. The configuration source is elected from auto-upstream ports. • auto-downstream: configures the port to accept the internally propagated DCB configuration from a configuration source.
Defaults Auto Command Modes INTERFACE PROTOCOL LLDP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. fcoe priority-bits Configure the FCoE priority advertised for the FCoE protocol in application priority TLVs. Syntax fcoe priority-bits priority-bitmap To remove the configured FCoE priority, use the no fcoe priority-bits command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module.
Field Description DCBX Operational Status Operational status (enabled or disabled) used to elect a configuration source and internally propagate a DCB configuration. The DCBX operational status is the combination of PFC and ETS operational status. Configuration Source Specifies whether the port serves as the DCBX configuration source on the switch: true (yes) or false (no). Local DCBX Compatibility mode DCBX version accepted in a DCB configuration as compatible.
Example Field Description Total DCBX Frames unrecognized Number of unrecognizable DCBX frames received.
Defaults None. There are no pre-configured PFC and ETS settings on S5000 Ethernet interfaces. Command Modes CONFIGURATION INTERFACE Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810 and S6000 platforms. A DCB map is a template used to configure DCB parameters and apply them on converged Ethernet interfaces. DCB parameters include priority-based flow control (PFC) and enhanced traffic selection (ETS).
Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810, S6000 platforms. PFC and ETS settings are not pre-configured on Ethernet ports. You must use the dcb-map command to configure different groups of 802.1p priorities with PFC and ETS settings. Using the priority-pgid command, you assign each 802.1p priority to one priority group. A priority group consists of 802.
NOTE: Please note that Dell Networking does not recommended to use this command as it has been deprecated in the current 9.4(0.0) release. A warning message appears when you try to run this command indicating that you have to use the dcb-map commands in the future. priority-group bandwidth pfc Configure the ETS bandwidth allocation and PFC mode used to manage port traffic in an 802.1p priority group. Parameters priority-group group-num Enter the keyword priority-group followed by the number of an 802.
If a priority group does not use its allocated bandwidth, the unused bandwidth is made available to other priority groups. To remove a priority-group configuration in a DCB map, enter the no priority-group bandwidth pfc command. By default, equal bandwidth is assigned to each dot1p priority in a priority group. Use the bandwidth parameter to configure the bandwidth percentage assigned to a priority group.
• Command History Usage Information EXEC Privilege Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810 and S6000 platforms. 9.3(0.0) Introduced on the FC Flex IO module installed in the MXL 10/40GbE Switch. Use the show qos dcb-map command to display the enhanced transmission selection (ETS) and prioritybased flow control (PFC) parameters used to configure server-facing Ethernet ports. S5000 Ethernet ports are DCBx-enabled by default.
total buffer space on the system being lower than the shared buffer size. You must either enter a smaller value for the shared buffer size or increase the total buffer size appropriately by using the dcb pfc-total- buffer-size command. Syntax dcb pfc-shared—buffer—size KB Parameters KB Enter a number in the range of 0 to 7787. Default The default is 1 KB for S6000 platforms. Command Modes CONFIGURATION mode Command History Usage Information Version Description 9.7(0.
Usage Information When you enter the profile name, you enter the DCB buffer threshold configuration mode. You can specify the shared buffer threshold limit, the ingress buffer size, buffer limit for pausing the acceptance of packets, and the buffer offset limit for resuming the acceptance of received packets. Example S4810-YU-MR-Dell(conf)#dcb buffer—threshold test priority Configure the priority for the PFC threshold to be allocated to the buffer space parameters.
You can use the priority command to set up both the administrative and peer-related PFC priorities. For example, you can configure the intended buffer configuration for all eight priorities. If you configure the number of lossless queues as 4 and if the administrator-configured priorities configured within the DCB input policy is applied, then the configuration for those priorities are pre-designed.
size Weightage of the priorities on the shared buffer size in the system. Enter a number in the range of 0 to 9. The default shared threshold weight is 10. Default The default size of the ingress buffer is 45 KB. The default buffer limit at which the port sends the pause to peer and recommences the sending of packets to the peer is 10 KB. The default threshold weight of the shared buffer space is 10. Command Modes DCB-BUFFER-THRESHOLD mode Command History Usage Information Version Description 9.
Command Modes Command History INTERFACE mode Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810, S4820T, and S6000 platforms. Usage Information You can configure up to a maximum of four lossless (PFC) queues. By configuring four lossless queues, you can configure four different priorities and assign a particular priority to each application that your network is used to process.
show qos dcb-buffer-threshold Displays the DCB buffer threshold assigned to a QoS policy. This command is supported on the platform. Syntax Parameters Command Modes show qos dcb buffer-threshold {name} name Enter the name of the profile, which can be a string of up to 32 characters in length. EXEC EXEC Privilege Command History Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S6000 platform.
Usage Information Version Description 9.3(0.0) Introduced on the S6000 platform. Configure the maximum buffer available for PFC traffic. You can choose to increase or decrease the buffer size that is currently allocated in the system by default. However, if you modify the PFC buffer size to be lower than the previously configured PFC buffer size, the system determines whether this reduction in size is valid without disrupting the existing configuration.
pfc priority 3 buffer-size 50 ! dcb-buffer-threshold test2 pfc priority 0 buffer-size 80 pause-threshold 50 ! dcb-buffer-threshold test3 pfc priority 0 buffer-size 80 pause-threshold 60 resume-threshold 30 On interface on which PFC is enabled: Show interface tengigabitethernet 1/1 pfc buffer-threshold -----------------------------------------------------------------------------------Queue# Lossless Buffer-size Pause-threshold Resume-offset Shared (KB) (KB) (KB) weight --------------------------------------
Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810 and S6000 platforms. Usage Information You can configure up to a maximum of four lossless (PFC) queues. By configuring four lossless queues, you can configure four different priorities and assign a particular priority to each application that your network is used to process.
14 Debugging and Diagnostics The basic debugging and diagnostic commands are supported by the Dell Networking Operating System. This chapter contains the following sections: • Diagnostic and Monitoring Commands • Offline Diagnostic Commands • Hardware Commands Diagnostics and Monitoring Commands The following section describes the diagnostics and monitoring commands. For similar commands, refer to the Control and Monitoring chapter. logging coredump stack-unit Enable coredump on a stack.
Offline Diagnostic Commands The offline diagnostics test suite is useful for isolating faults and debugging hardware. While tests are running, Dell Networking OS results are saved as a text file (TestReport-SU-X.txt) in the flash directory. This show file command is available only on master and standby. Important Points to Remember • Offline diagnostics can only be run when the unit is offline. • You can only run offline diagnostics on a unit to which you are connected via the console.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.
The system reboots when the off-line diagnostics complete. This reboot is an automatic process. A warning message appears when the offline stack-unit command is implemented. Warning - Diagnostic execution will cause stack-unit to reboot after completion of diags. Proceed with Offline-Diags [confirm yes/no]:y Related Commands show environment (S-Series) — views the S-Series system component status (for example, temperature, voltage). online stack-unit Place a stack unit in the online state.
Hardware Commands These commands display information from a hardware sub-component or ASIC. clear hardware stack-unit Clear statistics from selected hardware components.
clear hardware system-flow Clear system-flow statistics from selected hardware components. Syntax clear hardware system-flow layer2 stack-unit number port-set 0–0 counters Parameters stack-unit number Enter the keywords stack-unit then a number to select a particular stack member and then enter one of the following command options to clear a specific collection of data. The range is from 0 to 11.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced this command. hardware watchdog To trigger a reboot and restart the system, set the watchdog timer. Syntax hardware watchdog stack-unit {<0-5> | all} Defaults Enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. The unit numbers given are internal port numbers. show hardware layer3 Display Layer 3 ACL or QoS data for the selected stack member and stack member port-pipe.
show hardware stack-unit Display the data plane or management plane input and output statistics of the designated component of the designated stack member.
The following is a list of the Dell Networking OS version history for this command. Example (DataPlane) Version Description 9.8(0.0) Replaced the keyword port with interface. 9.7(0.0) Introduced on the S6000-ON. 9.2(0.2) Modified the drops keyword range, unit keyword range and added the buffer and cpu management statistics options. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.5 Added i2c statistics and sata-interfaces statistics. 8.3.11.
Example (PortStats) Dell#show hardware stack-unit 1 unit 0 ena/ speed/ link auto STP port link duplex scan neg? state pause ge0 down SW Yes Block ge1 !ena SW Yes Block ge2 !ena SW Yes Block ge3 !ena SW Yes Block ge4 !ena SW Yes Forward ge5 !ena SW Yes Forward ge6 !ena SW Yes Forward ge7 !ena SW Yes Forward ge8 !ena SW Yes Forward ge9 !ena SW Yes Forward ge10 !ena SW Yes Forward ge11 !ena SW Yes Forward ge12 !ena SW Yes Forward ge13 !ena SW Yes Forward ge14 !ena SW Yes Forward ge15 !ena SW Yes Forward ge16
0x0e700102 BCAST_BLOCK_MASK.ge0 = 0x00000000 0x0e701102 BCAST_BLOCK_MASK.ge1 = 0x00000000 0x0e702102 BCAST_BLOCK_MASK.ge2 = 0x00000000 0x0e703102 BCAST_BLOCK_MASK.ge3 = 0x00000000 0x0e704102 BCAST_BLOCK_MASK.ge4 = 0x00000000 0x0e705102 BCAST_BLOCK_MASK.ge5 = 0x00000000 0x0e706102 BCAST_BLOCK_MASK.ge6 = 0x00000000 0x0e707102 BCAST_BLOCK_MASK.ge7 = 0x00000000 0x0e708102 BCAST_BLOCK_MASK.ge8 = 0x00000000 0x0e709102 BCAST_BLOCK_MASK.ge9 = 0x00000000 0x0e70a102 BCAST_BLOCK_MASK.
RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX - Pause Control Frame Counter Oversized Frame Counter Jabber Frame Counter VLAN Tag Frame Counter Double VLAN Tag Frame Counter RUNT Frame Counter Fragment Counter VLAN Tagged Packets Ingress Dropped Packet MTU Check Error Frame Counter PFC Frame Priority 0 PFC Frame Priority 1 PFC Frame Priority 2 PFC
TX - Debug Counter 10 TX - Debug Counter 11 --------------------unit: 0 port: 61 (interface Fo 1/60) Description RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX TX TX TX TX TX TX TX TX TX 524 - IPV4 L3 Unicast Frame Counter IPV4 L3 Routed Multicast Packets IPV6 L3 Unicast Frame Counter IPV6 L3 Routed Multicast Packets Unicast Packet Counter 64 Byte Frame Counter 65 to 127 Byte Frame Counter 128 to 255 Byte
TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX Example (Details) - 4096 to 9216 Byte Frame Counter Good Packet Counter Packet/Frame Counter Unicast Frame Counter Multicast Frame Counter Broadcast Frame Counter Byte Counter Control Frame Counter Pause Control Frame Counter Oversized Frame Counter Jabber Counter VLAN Tag Frame Counter Double VLAN Tag Frame Counter RUNT Frame Counter Fragment Counter PFC Frame Priority 0 PFC Frame Priority 1 PFC Frame
The linkStatus of Front End Port 7 is FALSE The linkStatus of Front End Port 8 is FALSE The linkStatus of Front End Port 9 is FALSE The linkStatus of Front End Port 10 is FALSE The linkStatus of Front End Port 11 is FALSE The linkStatus of Front End Port 12 is FALSE The linkStatus of Front End Port 13 is FALSE The linkStatus of Front End Port 14 is FALSE The linkStatus of Front End Port 15 is FALSE The linkStatus of Front End Port 16 is FALSE The linkStatus of Front End Port 17 is FALSE The linkStatus of Fr
show processes cpu (S-Series) — displays the CPU usage information based on the processes running in an S-Series. show system (S-Series and Z-Series) — displays the current status of all the stack members or a specific member. show hardware buffer interface Display buffer statistics for a specific interface.
Example displaying queue range Dell#show hardware buffer interface tengigabitethernet 1/1 queue all buffer-info ----- Buffer Stats for Interface Te 1/1 Queue 0 ----Maximum Shared Limit: 29514 Default Packet Buffer allocate for the Queue: 8 Used Packet Buffer: 0 ----- Buffer Stats for Interface Te 1/1 Queue 1 ----Maximum Shared Limit: 29514 Default Packet Buffer allocate for the Queue: 8 Used Packet Buffer: 0 ----- Buffer Stats for Interface Te 1/1 Queue 2 ----Maximum Shared Limit: 29514 Default Packet Buff
interface interface Command Modes Enter any of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. queue Enter the keyword queue after id for specific queue or keyword all. priority-group Enter the keyword priority-group followed by id for specific priority-group or keyword all.
--------------------------------------UCAST 10 0 Dell#show hardware buffer-stats-snapshot resource interface fortyGigE 0/0 queue ucast all Unit 0 unit: 0 port: 1 (interface Fo 0/0) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------UCAST 0 0 UCAST 1 0 UCAST 2 0 UCAST 3 0 UCAST 4 0 UCAST 5 0 UCAST 6 0 UCAST 7 0 UCAST 8 0 UCAST 9 0 UCAST 10 0 UCAST 11 0 Example displaying egress queue-level snapshot for multicast packets for the specific interface Dell
4 5 6 7 0 0 0 0 0 0 0 0 show hardware counters interface Display the counter information for a specific interface. Syntax Parameters Defaults Command Modes Command History show hardware counters interface interface counters Enter the keywords counters to display counter value for the specified stackmember the port-pipe.
RX - Control Frame Counter RX - Pause Control Frame Counter RX - Oversized Frame Counter RX - Jabber Frame Counter RX - VLAN Tag Frame Counter RX - Double VLAN Tag Frame Counter RX - RUNT Frame Counter RX - Fragment Counter RX - VLAN Tagged Packets RX - Ingress Dropped Packet RX - MTU Check Error Frame Counter RX - PFC Frame Priority 0 RX - PFC Frame Priority 1 RX - PFC Frame Priority 2 RX - PFC Frame Priority 3 RX - PFC Frame Priority 4 RX - PFC Frame Priority 5 RX - PFC Frame Priority 6 RX - PFC Frame Pri
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.5 Added i2c statistics and sata-interfaces statistics. 8.3.11.4 Added user port information. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series.
Unknown Opcodes Internal Mac Receive Errors : 0 : 0 show hardware stack-unit buffer-stats-snapshot (Total Buffer Information) View the buffer statistics tracking resource information depending on the type of buffer information, such as device-level details, port-level counters, queue-based snapshots, or priority group-level snapshot in the egress and ingress direction of traffic.
Example Dell#show hardware stack-unit 1 buffer-stats-snapshot unit 3 resource interface all queue mcast 3 Unit 1 unit: 3 port: 1 (interface Fo 1/144) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------MCAST 3 0 Unit 1 unit: 3 port: 5 (interface Fo 1/148) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------MCAST 3 0 Unit 1 unit: 3 port: 9 (interface Fo 1/152) -------------------------------------
Parameters acl | qos For the selected stack member and stack member port-pipe, display which system flow entry the packet hits and what queue the packet takes as it dumps the raw system flow tables. stack-unit id Enter the keywords stack-unit to select a stack member ID. The range is from 0 to 11. port-set number [counters] Enter the keywords port-set with a port-pipe number. The range is from 0 to 0. (OPTIONAL) Enter the keyword counters to display hit counters for the selected ACL or QoS option.
1 25 Dell# Example L2BCASTPackets 0 param1=0(0x00)}, action={act=CosQCpuNew, param0=7(0x07), param1=0(0x00)}, action={act=CopyToCpu, param0=0(0x00), param1=0(0x00)}, action={act=UpdateCounter, param0=1(0x01), param1=0(0x00)}, meter=NULL, counter={idx=1, mode=0x01, entries=1} ############## FP Entry for redirecting LACP traffic to CPU Port ############ EID 2045: gid=1, slice=15, slice_idx=0x02, prio=0x7fd, flags=0x82, Installed tcam: color_indep=0, higig=0, higig_mask=0, KEY=0x00000000 00000000 00000000 0
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced this command.
15 Dynamic Host Configuration Protocol (DHCP) Dynamic host configuration protocol (DHCP) is an application layer protocol that dynamically assigns IP addresses and other configuration parameters to network end-stations (hosts) based on the configuration policies the network administrators determine. The Dell Networking operating system supports the basic DHCP commands on this platform.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. Entering after the clear ip dhcp binding command clears all the IPs from the binding table. debug ip dhcp server Display FTOS debugging messages for DHCP. S4820T Syntax debug ip dhcp server [events | packets] Parameters events Enter the keyword events to display the DHCP state changes.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. default-router Assign a default gateway to clients based on the address pool. S4820T Syntax Parameters default-router address [address2...address8] address Enter a list of routers that may be the default gateway for clients on the subnet. You may specify up to eight routers. List them in order of preference.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series.
Parameters name Give a name to the group of addresses in a pool. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
hardware-address For manual configurations, specify the client hardware address. S4820T Syntax hardware-address address Parameters address Enter the hardware address of the client. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. lease Specify a lease time for the addresses in a pool. S4820T Syntax Parameters lease {days [hours] [minutes] | infinite} days Enter the number of days of the lease. The range is from 0 to 31. hours Enter the number of hours of the lease. The range is from 0 to 23. minutes Enter the number of minutes of the lease. The range is from 0 to 59.
Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
network Specify the range of addresses in an address pool. S4820T Syntax network network /prefix-length Parameters network/ prefixlength Specify a range of addresses. Prefix-length range is from 17 to 31. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. show ip dhcp binding Display the DHCP binding table. S4820T Syntax show ip dhcp binding Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. show ip dhcp conflict Display the address conflict log. S4820T Syntax Parameters show ip dhcp conflict address address Display a particular conflict log entry.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. Commands to Configure Secure DHCP DHCP, as defined by RFC 2131, provides no authentication or security mechanisms. Secure DHCP is a suite of features that protects networks that use dynamic address allocation from spoofing and attacks.
Defaults Command Modes Command History Disabled • INTERFACE • INTERFACE PORT-CHANNEL This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Added the keywords discard-counters, interface, and the variable interface on the S4810, S4820T, S5000, S6000, Z9000, Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.
ip dhcp relay Enable Option 82. S4820T Syntax ip dhcp relay information-option [remote-id | trust-downstream] Parameters remote-id Configure the system to enable the remote-id string in option-82. trust-downstream Configure the system to trust Option 82 when it is received from the previous-hop router. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Usage Information Version Description 8.3.1.0 Introduced on the E-Series. 8.2.1.0 Introduced on the C-Series and S-Series on Layer 2 interfaces. 7.8.1.0 Introduced on the C-Series and S-Series on Layer 3 interfaces. When enabled, no learning takes place until you enable snooping on a VLAN. After disabling DHCP snooping, the binding table deletes and Option 82, IP Source Guard, and Dynamic ARP Inspection are disabled. Introduced in Dell Networking OS version 7.8.1.
Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp snooping binding Create a static entry in the DHCP binding table. S4820T Syntax Parameters Defaults Command Modes Command History [no] ip dhcp snooping binding mac address vlan-id vlan-id ip ip-address interface type slot/port lease number mac address Enter the keyword mac then the MAC address of the host to which the server is leasing the IP address.
Related Commands Version Description 7.8.1.0 Introduced on the C-Series and S-Series. show ip dhcp snooping — displays the contents of the DHCP binding table. IPv6 DHCP Snooping Binding Create a static DHCP snooping binding entry in the snooping database.
ip dhcp snooping database Delay writing the binding table for a specified time. S4820T Syntax Parameters ip dhcp snooping database write-delay minutes minutes The range is from 5 to 21600. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp snooping database renew Renew the binding table. S4820T Syntax ip dhcp snooping database renew Defaults none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
ip dhcp snooping trust Configure an interface as trusted. S4820T Syntax [no] ip dhcp snooping trust Defaults Untrusted Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
vlan vlan-id Defaults Disabled Command Modes INTERFACE (OPTIONAL) SAV validates the source IP address along with the source VLAN ID against the DHCP snooping binding table. INTERFACE PORTCHANNEL Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
NOTE: Adds the VPN/VRF related sub-options into the relay agent information option(82). When DHCP broadcasts are forwarded by the relay agent from clients to DHCP server. Default Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
Version Description 8.3.1.0 Introduced on the E-Series. 7.2.1.0 Introduced on the C-Series and S-Series. ipv6 dhcp snooping verify mac-address Syntax [no] ipv6 dhcp snooping verify mac-address To disable verify source mac-address against IPv6 DHCP packet MAC address, use the no ipv6 dhcp snooping verify mac-address command. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Usage Information Use this command on the interfaces where the DHCP clients are connected to forward the packets from clients to DHCP server and vice-versa. Example Dell(conf-if-te-1/12)#ip helper-address vrf jay 10.0.0.2 ipv6 helper-address Configures the ipv6 DHCP helper addresses without VRF. Syntax [no] ipv6 helper-address ipv6-address To delete the ipv6 helper address, use the [no] ipv6 helper-address ipv6-address command.
interface interface (OPTIONAL) Specifies an interface to show the discard counters. Enter any of the following keywords and slot/port or number information: Defaults • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
permit host 0.0.0.0 host 00:00:00:00:00:00 count (0 packets) permit vlan 10 host 1.1.1.1 host 00:00:00:00:01:01 count (0 packets) permit vlan 10 host 1.1.1.2 host 00:00:00:00:01:02 count (0 packets) permit vlan 10 host 1.1.1.3 host 00:00:00:00:01:03 count (0 packets) ipmac-vlan sav access-list on Port-channel 10 on stack-unit 1 Total cam count 5 permit host 0.0.0.0 host 00:00:00:00:00:00 count (0 packets) permit vlan 10 host 1.1.1.1 host 00:00:00:00:01:01 count (0 packets) permit vlan 10 host 1.1.1.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. Dell#show ipv6 dhcp snooping IPv6 DHCP Snooping IPv6 DHCP Snooping Mac Verification : Enabled. : Disabled.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S-Series and Z-Series. Usage Information Use this command to associate name server IP addresses to a specific VRF.
ip domain-list Adds a domain name to the DNS list. This domain name is appended to incomplete host names in DNS requests corresponding to a specific VRF. S4820T Syntax ip domain-list [vrf vrf-name] name To remove a domain name from DNS list, use the no ip domain-list [vrf vrf-name] name command. Parameters vrf vrf-name (Optional) Enter the key word vrf and then the name of the VRF to add a domain name to the DNS list corresponding to that VRF.
ip-address Enter the IP address of the name server in dotted decimal format. Defaults None Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S-Series and Z-Series.
16 Equal Cost Multi-Path (ECMP) Equal cost multi-path (ECMP) is supported on the Dell Networking OS. ecmp-group Provides a mechanism to monitor traffic distribution on an ECMP link bundle. A system log is generated when the standard deviation of traffic distribution on a member link exceeds a defined threshold. S4820T Syntax ecmp-group {ecmp-group-id interface interface | link-bundle-monitor} To remove the selected interface, use the ecmp-group no interface command.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. Using CONFIGURATION mode, create an ECMP group ID. You can then assign interfaces to the ECMP group using CONFIGURATION ECMP-GROUP mode. You can also enable on the port-channel configuration using the CONFIGURATION ECMP-GROUP command mode. hash-algorithm Changes the hash algorithm used to distribute traffic flows across a Port Channel. The ECMP and LAG options are supported on the Z-Series.
hg {crc16 | crc16cc | crc32MSB | crc32LSB | xor1 | xor2 | xor4 | xor8 | xor16} stack-unit stack-unit-number | port-set port-pipe • xor8: Use CRC16_BISYNC_AND_XOR8 — Upper 8 bits of CRC16-BISYNC and lower 8 bits of xor8 • xor16: Use CR16 — 16 bit XOR Z-Series only: Enter the keyword hg then one of the following options: • crc16: Use CRC16_BISYNC — 16 bit CRC16-bisync polynomial (default) • crc16cc: Use CRC16_CCITT — 16 bit CRC16 using CRC16-CCITT polynomial • crc32MSB: Use CRC32_UPPER — MSB 16 bits
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. 8.1.1.
hash-algorithm ecmp Change the hash algorithm used to distribute traffic flows across an ECMP (equal-cost multipath routing) group. S4820T Term heading Description heading Syntax hash-algorithm ecmp {crc-upper} | {dest-ip} | {lsb} To return to the default hash algorithm, use the no hash-algorithm ecmp command. Parameters Defaults crc-upper Uses the upper 32 bits of the key for the hash computation. The default is crclower. dest-ip Uses the destination IP for ECMP hashing. The default is enabled.
hash-algorithm seed Select the seed value for the ECMP, LAG, and NH hashing algorithm. S4820T Syntax Parameters hash-algorithm seed value [stack-unitslot/port] [port-set number] seed value Enter the keyword seed then the seed value. The range is from 0 to 2,147,483,646. stack–unit slot/port Enter the keyword stack-unit then the slot/port number. The range is from 0 to 11. port-set number Enter the keyword port-set then the port-pipe number. The value is 0.
ip ecmp-group Enable and specify the maximum number of ecmp that the L3 CAM hold for a route, By default, when maximum paths are not configured, the CAM can hold a maximum of 16 ecmp per route. S4820T Syntax ip ecmp-group {maximum-paths | {number} {path-fallback} To negate a command, use the no ip ecmp-group maximum-paths {number} command. Parameters maximum-paths Specify the maximum number of ECMP for a route. The range is 2 to 64. path-fallback Use the keywords path-fallback to enable this feature.
If disabled, the CLI would inform the FIB to re-program the destination prefix paths with no weights or regular ECMP.
link-bundle-monitor enable Provides a mechanism to enable monitoring of traffic distribution on an ECMP link bundle. S4820T Syntax link-bundle-monitor enable To exit from ECMP group mode, use the exit command. Command Modes Command History • ECMP-GROUP • PORT-CHANNEL INTERFACE This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show link-bundle distribution Display the link-bundle distribution for the interfaces in the bundle, type of bundle (LAG or ECMP), and the most recently calculated interface utilization (either bytes per second rate or maximum rate) for each interface. S4820T Syntax show link-bundle-distribution Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
17 FIPS Cryptography To configure federal information processing standards (FIPS) cryptography, use the following commands: fips mode enable Enable the FIPS cryptography mode on the platform. Syntax [no] fips mode enable To disable the FIPS cryptography mode, use the no fips mode enable command.
Dell#show fips status FIPS Mode : Enabled Dell# Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.1(0.0) Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
SSH server version : v2. SSH server vrf : default. SSH server ciphers : 3des-cbc,aes128-cbc,aes192-cbc,aes256cbc,aes128-ctr,aes192-ctr,aes256-ctr. SSH server macs : hmac-sha1-96. SSH server kex algorithms : diffie-hellman-group14-sha1. Password Authentication : enabled. Hostbased Authentication : disabled. RSA Authentication : disabled. Vty Encryption HMAC Remote IP 0 3des-cbc hmac-sha1-96 10.1.20.48 1 3des-cbc hmac-sha1-96 10.1.20.48 With FIPS Mode disabled: Dell#show ip ssh SSH server : enabled.
• aes128–ctr: Force ssh to use the aes256–cbc encryption cipher. • aes192–ctr: Force ssh to use the aes128–cbc encryption cipher. • aes256–cbc: Force ssh to use the aes256–cbc encryption cipher. -l username (OPTIONAL) Enter the keyword —l then the user name used in this SSH session. The default is the user name of the user associated with the terminal. -m HMAC algorithm Enter one of the following HMAC algorithms to use. (For v2 clients only.
show ip ssh clientpub-keys Usage Information Display the client-public keys. Dell Networking OS supports both inbound and outbound SSH sessions using IPv4 or IPv6 addressing. Inbound SSH supports accessing the system through the management interface as well as through a physical Layer 3 interface. NOTE: Some of the parameters in this command require licensing to access. For more information, contact your Dell Networking representative. Example If FIPS mode is not enabled: Dell#ssh 10.10.10.
18 FIP Snooping To enable the FCoE Transit feature and configure FIP snooping, use the following Dell Networking Operating System commands on the S4820T platform. In a converged Ethernet network, a switch can operate as an intermediate Ethernet bridge to snoop on FIP packets during the login process on Fibre Channel over Ethernet (FCoE) forwarders (FCFs).
clear fip-snooping statistics Clears the statistics on the FIP packets snooped on all VLANs, a specified VLAN, or a specified port interface. S4820T Syntax clear fip-snooping statistics [interface vlan vlan-id | interface fortyGigEport-type port/slot | interface port-channel port-channel-number] Parameters vlan-id Enter the VLAN ID of the FIP packet statistics to be cleared. port-type port/slot Enter the port-type and slot number of the FIP packet statistics to be cleared.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. debug fip snooping rx Enable debugging for FIP snooping receive-specific packets.
Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 9.2(0.2) Introduced on the S4810 and S4820T. Added the receive parameters packettype and interfaces and their options. feature fip-snooping Enable FCoE transit and FIP snooping on a switch. S4820T Syntax feature fip-snooping To disable the FCoE transit feature, use the no feature fip-snooping command. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. The maximum number of FCFs supported per FIP snooping-enabled VLAN is four.
fip-snooping max-sessions-per-enodemac Configure the maximum session limit per ENode MAC address. S4820T Syntax fip-snooping max—sessions—per—enode—mac max-sessions-value To return the configured maximum sessions to the default value, use the no fip-snooping max— sessions—per—enode—mac command. Parameters max-sessions-value Enter the maximum number of sessions allowed per ENode MAC address. The range is from 1 to 64.
fip-snooping port-mode fcoe-trusted Configure the port for bridge-to-bridge links. S4820T Syntax fip-snooping port-mode fcoe-trusted To remove the bridge-to-bridge link configuration from the port, use the no fip-snooping port-mode fcoe-trusted command. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Dell# show fip-snooping config FIP Snooping Feature enabled Status: Enabled FIP Snooping Global enabled Status: Enabled Global FC-MAP Value: 0X0EFC00 FIP Snooping enabled VLANs VLAN Enabled FC-MAP ----------------100 TRUE 0X0EFC00 show fip-snooping enode Display information on the ENodes in FIP-snooped sessions, including the ENode interface and MAC address, FCF MAC address, VLAN ID and FC-ID.
--------- --------------- ------- ---- ----d4:ae:52:1b:e3:cd Te 1/11 54:7f:ee:37:34:40 100 62:00:11 show fip-snooping fcf Display information on the FCFs in FIP-snooped sessions, including the FCF interface and MAC address, FCF interface, VLAN ID, FC-MAP value, FKA advertisement period, and number of ENodes connected. S4820T Syntax Parameters Command Modes Command History show fip-snooping fcf [fcf-mac-address] fcf-mac-address • EXEC • EXEC Privilege Enter the MAC address of the FCF to display.
show fip-snooping statistics Display statistics on the FIP packets snooped on all interfaces, including VLANs, physical ports, and port channels. S4820T Syntax show fip-snooping statistics [interface vlan vlan-id | interface port-type port/slot | interface port-channel port-channel-number] Parameters Command Modes Command History vlan-id Enter the VLAN ID of the FIP packet statistics displays. port-type port/slot Enter the port-type and slot number of the FIP packet statistics displays.
Example Field Description Number of VN Port Keep Alives Number of FIP-snoop VN port (Virtual N-port) keep-alive frames received on the interface Number of Multicast Discovery Advertisements Number of FIP-snoop multicast discovery advertisements received on the interface. Number of Unicast Discovery Advertisements Number of FIP-snoop unicast discovery advertisements received on the interface. Number of FLOGI Accepts Number of FIP FLOGI accept frames received on the interface.
Number of Session failures due to Hardware Config :0 Dell(conf)# Dell# show fip-snooping statistics int tengigabitethernet 1/11 Number of Vlan Requests :1 Number of Vlan Notifications :0 Number of Multicast Discovery Solicits :1 Number of Unicast Discovery Solicits :0 Number of FLOGI :1 Number of FDISC :16 Number of FLOGO :0 Number of Enode Keep Alive :4416 Number of VN Port Keep Alive :3136 Number of Multicast Discovery Advertisement :0 Number of Unicast Discovery Advertisement :0 Number of FLOGI Accepts :
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
show fips status Display the FIPs status on the platform. S4820T Syntax show fips status Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. 598 FIP Snooping Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.
19 Force10 Resilient Ring Protocol (FRRP) Force10 resilient ring protocol (FRRP) is supported on Dell Networking OS. FRRP is a proprietary protocol for that offers fast convergence in a Layer 2 network without having to run the spanning tree protocol (STP). The resilient ring protocol is an efficient protocol that transmits a high-speed token across a ring to verify the link status. All the intelligence is contained in the master node with practically no intelligence required of the transit mode.
Usage Information Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series. 7.5.1.0 Introduced. Executing this command without the optional ring-id command clears the statistics counters on all the available rings. Dell Networking OS requires a command line confirmation before the command executes.
Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 8.2.1.0 Introduced on the C-Series. 7.4.1.0 Introduced. disable Disable the resilient ring protocol. S4820T Syntax disable To enable the Resilient Ring Protocol, use the no disable command. Defaults Disabled Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters primary interface secondary interface control-vlan vlan-id Enter the keyword primary to configure the primary interface then one of the following interfaces and slot/port information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
member-vlan Specify the member VLAN identification numbers. S4820T Syntax member-vlan {vlan-range} To return to the default, use the no member-vlan [vlan-range] command. Parameters vlan-range Enter the member VLANs using VLAN IDs (separated by commas), a range of VLAN IDs (separated by a hyphen), a single VLAN ID, or a combination. For example: VLAN IDs (comma-separated): 3, 4, 6. Range (hyphen-separated): 5-10. Combination: 3, 4, 5-10, 8.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series. 7.4.1.
Usage Information This command places you into the resilient ring protocol. After executing this command, the command line prompt changes to conf-frrp. show frrp Display the resilient ring protocol configuration. S4820T Syntax show frrp [ring-id [summary]] | [summary] Parameters ring-id Enter the ring identification number. The range is from 1 to 255 summary (OPTIONAL) Enter the keyword summary to view just a summarized version of the Ring configuration.
• The number of state change counters Example (Summary) Dell#show frrp summary Ring-ID State Mode Ctrl_Vlan Member_Vlans ---------------------------------------------2 UP Master 2 11-20, 25,27-30 31 UP Transit 31 40-41 50 Down Transit 50 32 Dell# Example (1) Dell#show frrp 1 Ring protocol 1 is in Master mode Ring Protocol Interface: Primary : TenGigabitEthernet 1/16 State: Forwarding Secondary: Port-channel 100 State: Blocking Control Vlan: 1 Ring protocol Timers: Hello-Interval 50 msec Dead-Interval 150
NOTE: The configured dead interval must be at least three times the hello interval. Defaults • 500 ms for hello-interval milliseconds • 1500 ms for dead-intervalmilliseconds Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
20 GARP VLAN Registration (GVRP) The Dell Networking operating system supports the basic GVRP commands on the Dell Networking OS. The generic attribute registration protocol (GARP) mechanism allows the configuration of a GARP participant to propagate through a network quickly. A GARP participant registers or de-registers its attributes with other participants by making or withdrawing declarations of attributes.
clear gvrp statistics Clear GVRP statistics on an interface. S4820T Syntax clear gvrp statistics interface interface Parameters interface interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
To disable debugging, use the no debug gvrp {config | events | pdu} command. Parameters config Enter the keyword config to enable debugging on the GVRP configuration. event Enter the keyword event to enable debugging on the JOIN/LEAVE events. pdu Enter the keyword pdu then one of the following Interface keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series gvrp enable — enables GVRP on physical interfaces and LAGs. protocol gvrp — access GVRP protocol.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series disable — globally disables GVRP. gvrp registration Configure the GVRP register type. S4820T Syntax gvrp registration {fixed | normal | forbidden} To return to the default, use the gvrp register normal command.
Usage Information Fixed registration prevents an interface, configured using the command line, to belong to a VLAN (static configuration) from being unconfigured when it receives a Leave message. Therefore, Registration mode on that interface is fixed. Normal registration is the default registration. The port’s membership in the VLAN depends on GVRP. The interface becomes a member of a VLAN after learning about the VLAN through GVRP.
show config Display the global GVRP configuration. S4820T Syntax show config Command Modes CONFIGURATION-GVRP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series Example Dell#show garp timers GARP Timers Value (milliseconds) ---------------------------------------Join Timer 200 Leave Timer 600 LeaveAll Timer 10000 Dell# Related Commands garp timers — sets the intervals (in milliseconds) for sending GARP messages.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series Usage Information If no ports are GVRP participants, the message output changes from GVRP Participants running on to GVRP Participants running on no ports. Example R3#show gvrp brief GVRP Feature is currently enabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 7.6.1.
21 High Availability (HA) High availability (HA) in the Dell Networking operating software is configuration synchronization to minimize recovery time in the event of a route processor module (RPM) failure. The feature is available on Dell Networking OS. In general, a protocol is defined as “hitless” in the context of an RPM failure/failover and not failures of a line card, SFM, or power module. A protocol is defined as hitless if an RPM failover has no impact on the protocol.
There is no need to reload or reboot the system when you insert the patch. The In-Service Modular patch replaces the existing process code. After installation is complete, the system executes the patch code as though it was always there. Related Commands show patch — displays the system patches loaded with the in-service modular hot fix command. process restartable Enable a process to be restarted. Restartability is subject to a maximum restart limit.
redundancy auto-failover-limit Specify an auto-failover limit for RPMs. When a non-recoverable fatal error is detected, an automatic RPM failover occurs. This command does not affect user-initiated (manual) failovers. S4820T Syntax redundancy auto-failover-limit [count number [period minutes] | period minutes]] To disable the auto-failover limit control, use the no redundancy auto-failover-limit command.
redundancy disable-auto-reboot Prevent the system from auto-rebooting the failed module. S4820T Syntax redundancy disable-auto-reboot stack-unit [0–11 | members} [rpm| card number | all] To return to the default, use the no redundancy disable-auto-reboot stack-unit rpm command. Parameters rpm Enter the keyword rpm to disable auto-reboot of the failed RPM. stack-unit Enter the keyword stack-unit then the stack-unit ID number. Default Disabled (that is, the failed module is automatically rebooted).
Parameters stack-unit Enter the keyword stack-unit then the stack-unit ID number. Default Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.2(0.0) Introduced on the M I/O Aggregator.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series. redundancy protocol Enable hitless protocols. S4820T Syntax redundancy protocol {lacp | xstp} To disable a hitless protocol, use the no redundancy protocol {lacp | xstp} command. Parameters lacp Enter the keyword lacp to make LACP hitless.
redundancy reset-counter Reset failover counter and timestamp information displayed in the show redundancy command. S4820T Syntax redundancy reset-counter Default Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.
secondary RPM. When you execute this command, the logical SFM on the standby RPM is immediately taken offline and the SFM state is set as “standby”. NOTE: This command could affect traffic when taking the secondary SFM offline. Example Dell#show sfm all Switch Fabric State: up -- Switch Fabric Modules -Slot Status -------------------------------------0 active 1 active Dell#configure Dell(conf)#redundancy sfm standby Taking secondary SFM offline...
The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series. show patch Display the system patches loaded with the In-Service Modular Hot Fix command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced on the E-Series.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series. The following describes the show redundancy command shown in the following example. Field Description RPM Status Displays the following information: • Slot number of the RPM. • Whether the RPM is Primary or Standby. • The state of the RPM: Active, Standby, Booting, or Offline. • Whether the link to the second RPM is up or down.
Stack-unit ID: Stack-unit Redundancy Role: Stack-unit State: Stack-unit SW Version: Link to Peer: Peer Stack-unit: 0 Primary Active FIT-R2D2-1-0-0-89 Down not present -- Stack-unit Redundancy Configuration ------------------------------------------------Primary Stack-unit: mgmt-id 0 Auto Data Sync: Full Failover Type: Hot Failover Auto reboot Stack-unit: Disabled Auto failover limit: 3 times in 60 minutes -- Stack-unit Failover Record ------------------------------------------------Failover Count: 0 Last
SFM Config State: succeeded Jul 13 2007 21:28:53 Runtime Event Log: succeeded Jul 13 2007 21:28:53 Running Config: succeeded Jul 13 2007 21:28:53 Dell# 632 High Availability (HA)
22 ICMP Message Types This chapter lists and describes the possible ICMP message type resulting from a ping. The first three columns list the possible symbol or type/code. For example, you would receive a ! or 03 as an echo reply from your ping. ICMP Messages and Their Definitions. Symbol Type Code . Query Error Timeout (no reply) ! 0 U 3 C Description 4 3 echo reply . destination unreachable: 0 network unreachable . 1 host unreachable . 2 protocol unreachable .
Symbol & Type Code Description Query 8 0 echo request . 9 0 router advertisement . 10 0 router solicitation . 11 time exceeded: 0 time-to-live equals 0 during transit . 1 time-to-live equals 0 during reassembly . 12 634 Error parameter problem: 1 IP header bad (catchall error) . 2 required option missing . 13 0 timestamp request . 14 0 timestamp reply . 15 0 information request (obsolete) . 16 0 information reply (obsolete) . 17 0 address mask request .
23 Internet Group Management Protocol (IGMP) The IGMP commands are supported by the Dell Networking operating software on the Dell Networking OS. This chapter contains the following sections: • IGMP Commands • IGMP Snooping Commands IGMP Commands Dell Networking OS supports IGMPv1/v2/v3 and is compliant with RFC-3376.
• For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF.
• For a port channel interface, enter the keywords port-channel then a number. Defaults Disabled. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. 7.6.1.0 Introduced on E-Series. The access list accepted is an extended ACL. To block IGMP reports from hosts, on a per-interface basis based on the group address and source address that you specify in the access list, use this feature.
ip igmp immediate-leave Enable IGMP immediate leave. S4820T Syntax ip igmp immediate-leave [group-list prefix-list-name] To disable ip igmp immediate leave, use the no ip igmp immediate-leave command. Parameters group-list prefix-listname Enter the keywords group-list then a string up to 16 characters long of the prefix-list-name. Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific.
Parameters milliseconds Enter the number of milliseconds as the interval. For IGMP version 2, the range is from 100 to 25599. For IGMP version 3, the range is from 100 to 65535. The default value is 1000 milliseconds. Defaults 1000 milliseconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Maximum range of the Hello interval value is changed to 18000. Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.6.1.
Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the S-Series in Interface VLAN mode only to enable the system to act as an IGMP Proxy Querier. 7.5.1.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. 7.7.1.0 Introduced on the E-Series. Usage Information Mapping applies to both v1 and v2 IGMP joins; any updates to the ACL are reflected in the IGMP groups. You may not use extended access lists with this command.
show ip igmp groups View the IGMP groups. S4820T Syntax show ip igmp [vrf vrf-name] groups [group-address [detail] | detail | interface [group-address [detail]]] Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. group-address (OPTIONAL) Enter the group address in dotted decimal format to view information on that group only.
Usage Information This command displays the IGMP database, including configured entries for either all groups on all interfaces, all groups on specific interfaces, or specific groups on specific interfaces. The following describes the show ip igmp groups command shown in the following example. Example Example (VLT) Field Description Group Address Lists the multicast address for the IGMP group. Interface Lists the interface type, slot and port number. Mode Displays the IGMP version used.
65.0.0.4 65.0.0.5 00:01:22 00:01:22 show ip igmp interface View information on the interfaces participating in IGMP. S4820T Syntax show ip igmp [vrf vrf-name] interface [interface] Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to view IGMP interfaces associated with that VRF.
Example Dell#show ip igmp interface TenGigabitEthernet 1/1 is down, line protocol is down Internet protocol processing disabled TenGigabitEthernet 1/5 is down, line protocol is down Internet protocol processing disabled TenGigabitEthernet 1/6 is down, line protocol is down Internet protocol processing disabled TenGigabitEthernet 1/7 is up, line protocol is down Internet protocol processing disabled Vlan 20 Inbound IGMP access group is not set Internet address is 35.0.0.
group Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Enter the multicast group address in the form A.B.C.D to display the list of sources to which this group is mapped. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF.
• A maximum of 1800 groups and 600 VLAN are supported. • IGMP snooping is not supported on a default VLAN interface. • IGMP snooping is not supported over VLAN-Stack-enabled VLAN interfaces (you must disable IGMP snooping on a VLAN interface before configuring VLAN-Stack-related commands). • IGMP snooping does not react to Layer 2 topology changes triggered by spanning tree protocol (STP).
debug ip igmp snooping Enable debugging of IGMP snooping packets on interfaces and groups. S4820T Syntax debug ip igmp snooping [group address | interface] Parameters • To disable debugging of IGMP snooping, use the no debug ip igmp snooping [group address | interface] command. • To disable all debugging, use the undebug all command. snooping Enter the keyword snooping to enable debugging of IGMP snooping. group-address (OPTIONAL) Enter the IP multicast group address in dotted decimal format.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command. Usage Information Queriers normally send some queries when a leave message is received prior to deleting a group from the membership database. There may be situations when you require a fast deletion of a group.
ip igmp snooping last-member-query-interval The last member query interval is the maximum response time inserted into Group-Specific queries sent in response to Group-Leave messages. S4820T Syntax ip igmp snooping last-member-query-interval milliseconds To return to the default value, use the no ip igmp snooping last-member-query-interval command. Parameters milliseconds Enter the interval in milliseconds. The range is from 100 to 65535. The default is 1000 milliseconds.
To delete a specific multicast router interface, use the no igmp snooping mrouter interface interface command. Parameters interface interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
To disable IGMP querier processing for the VLAN interface, use the no ip igmp snooping querier command. Defaults Not configured. Command Modes INTERFACE VLAN — (conf-if-vl-n) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.
detail Command Modes Command History • EXEC • EXEC Privilege • For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. (OPTIONAL) Enter the keyword detail to display the IGMPv3 source information. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters Command Modes Command History vlan number • EXEC • EXEC Privilege Enter the keyword vlan then the vlan number. The range is from 1 to 4094. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.0.2.
24 Interfaces The commands in this chapter are supported by Dell Networking operating software on the S8420T platform. This chapter contains the following sections: • Basic Interface Commands • Port Channel Commands • Time Domain Reflectometer (TDR) • UDP Broadcast Basic Interface Commands The following commands are for Physical, Loopback, and Null interfaces.
vrrp [[ipv6] vrid] (OPTIONAL) Enter the keyword vrrp to clear the counters of all VRRP groups. To clear the counters of VRRP groups on all IPv6 interfaces, enter ipv6. To clear the counters of a specified group, enter a VRID number from 1 to 255. learning-limit (OPTIONAL) Enter the keywords learning-limit to clear unknown source address (SA) drop counters when MAC learning limit is configured on the interface. vlan vlan-id Enter the keyword vlan followed by the interface VLAN number.
clear dampening Clear the dampening counters on all the interfaces or just the specified interface. S4820T Syntax clear dampening [interface] Parameters interface (OPTIONAL) Enter any of the following keywords and slot/port or number to clear counters from a specified interface: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
dampening — configures dampening on an interface. dampening Configure dampening on an interface. S4820T Syntax Parameters dampening [[[[half-life] [reuse-threshold]] [suppress-threshold]] [maxsuppress-time]] half-life Enter the number of seconds after which the penalty is decreased. The penalty decreases half after the half-life period expires. The range is from 1 to 30 seconds. The default is 5 seconds.
• suppress-threshold should be greater than reuse-threshold • max-suppress-time should be at least 4 times half-life NOTE: You cannot apply dampening on an interface that is monitoring traffic for other interfaces. Example Dell(conf-if-te-1/10)#dampening 20 800 4500 120 Dell(conf-if-te-1/10)# Related Commands clear dampening — clears the dampening counters on all the interfaces or just the specified interface. show interfaces dampening — displays interface dampening information.
• Entering a text string after the description command overwrites any previous text string that you previously configured as the description. • The shutdown and description commands are the only commands that you can configure on an interface that is a member of a port-channel. • Use the show interfaces description command to display descriptions configured for each interface. duplex (10/100 Interfaces) Configure duplex mode on any physical interfaces where the speed is set to 10/100.
flowcontrol Control how the system responds to and generates 802.3x pause frames on 10 Gig ports. Syntax flowcontrol rx {off | on} tx {off | on} [negotiate] Parameters rx on Enter the keywords rx on to process the received flow control frames on this port. This is the default value for the receive side. rx off Enter the keywords rx off to ignore the received flow control frames on this port.
Important Points to Remember • Do not enable tx pause when buffer carving is enabled. For information and assistance, consult Dell Networking TA • The only configuration applicable to half duplex ports is rx off tx off. The following error is returned: Can’t configure flowcontrol when half duplex is configure, config ignored • Half duplex cannot be configured when the flow control configuration is on (default is rx on tx on).
Related Commands off off on off on off off off off on on on off off on on off off on on off on on on off off on on off off on on off off on on off off on on show running-config — displays the flow configuration parameters (non-default values only). show interfaces — displays the negotiated flow control parameters. interface Configure a physical interface on the switch.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Introduced You cannot delete a physical interface.
Parameters interface, interface,... Enter the keywords interface group and one of the interfaces — slot/port or VLAN number. Select the range of interfaces for bulk configuration. Spaces are not required between the commas. Comma-separated ranges can include VLANs and physical interfaces. Enter the member VLANs using VLAN IDs (separated by commas), a range of VLAN IDs (separated by a hyphen), a single VLAN ID, or a combination. For example: VLAN IDs (comma-separated): 3, 4, 6.
interface loopback Configure a Loopback interface. S4820T Syntax interface loopback number To remove a loopback interface, use the no interface loopback number command. Parameters number Enter a number as the interface number. The range is from 0 to 16383. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters slot/port Enter the keyword ManagementEthernet, then the slot number (0 or 1) and port number zero (0). Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
required between the commas. The ranges can include VLANs, port-channels, and physical interfaces. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094.
• If overlapping port ranges are specified, the port range is extended to the smallest start port and the biggest end port.
interface range macro (define) — defines a macro for an interface-range. interface range macro (define) Defines a macro for an interface range and then saves the macro in the running configuration. S4820T Syntax define interface range macro name interface , interface , ... Parameters name Enter up to 16 characters for the macro name. interface, interface,... Enter the keywords interface range and one of the interfaces — slot/port, port-channel, or VLAN number.
Example (Single Range) Version Description pre-Version 6.1.1.0 Introduced on the E-Series. This example shows how to define an interface range macro named test. Execute the show runningconfig command to display the macro definition.
Example (Single Range) This example shows the macro named test that was defined earlier. Dell(config)#interface range macro test Dell(config-if-range-te-1/1-3,te-5/1-47,te-13/1-89)# Dell Related Commands interface range — configures a range of command (bulk configuration). interface range macro (define) — defines a macro for an interface range (bulk configuration). interface vlan Configure a VLAN. You can configure up to 4094 VLANs.
If OpenFlow VLANs are configured on the switch, spanning-tree protocols cannot be enabled simultaneously. Example (Single Range) Dell(conf)#int vlan 3 Dell(conf-if-vl-3)# Related Commands interface — configures a physical interface. interface loopback — configures a loopback interface. interface null — configures a null interface. interface port-channel — configures a port channel group. show vlan — displays the current VLAN configuration on the switch. shutdown — disables/enables the VLAN.
• interface loopback — configures a loopback interface. • interface null — configures a null interface. • interface port-channel — configures a port channel group. negotiation auto Enable auto-negotiation on an interface. S4820T Syntax negotiation auto To disable auto-negotiation, use the no negotiation auto command. Defaults Enabled. Command Modes INTERFACE Command History This guide is platform-specific.
• Master • Slave • Auto-neg Error — typically indicates that both ends of the node are configured with forced-master or forced-slave. CAUTION: Ensure that one end of your node is configured as forced-master and one is configured as forced-slave. If both are configured the same (that is, forced-master or forced-slave), the show interfaces command flaps between an auto-neg-error and forced-master/slave states. You can display master/slave settings with the show interfaces command.
• auto-negotiation disabled speed 100 Link Status Between Port 1 and Port 2 • Up at 1000 Mb/s • Up at 100 Mb/s • Up at 100 Mb/s • Down • Down * You cannot disable auto-negotiation when the speed is set to 1000 or auto. keepalive Send keepalive packets periodically to keep an interface alive when it is not transmitting data. S4820T Syntax keepalive To stop sending keepalive packets, use the no keepalive command. Defaults Enabled.
monitor interface Monitor counters on a single interface or all interfaces on a line card. The screen is refreshed every five seconds and the CLI prompt disappears. Syntax monitor interface [interface] To disable monitoring and return to the CLI prompt, press the q key.
Example (Single Interface) Key Description systest-3 Displays the host name assigned to the system. monitor time Displays the amount of time since the monitor interface command was entered. time Displays the amount of time the chassis is up (since last reboot). m Change the view from a single interface to all interfaces on the line card or visaversa. c Refresh the view. b Change the counters displayed from Packets on the interface to Bytes.
Te 0/2 Up 61512 52 66160 42 Te 0/3 Up 63086 20 9405888 24 Te 0/4 Up 14697471418 2661481 13392989657 2661385 Te 0/5 Up 3759 3 161959604 832816 Te 0/6 Up 4070 3 8680346 5 Te 0/7 Up 61934 34 138734357 72 Te 0/8 Up 61427 1 59960 1 Te 0/9 Up 62039 53 104239232 3 Te 0/10 Up 17740044091 372 7373849244 79 Te 0/11 Up 18182889225 44 7184747584 138 Te 0/12 Up 18182682056 0 3682 1 Te 0/13 Up 18182681434 43 6592378911 144 Te 0/14 Up 61349 55 86281941 15 Te 0/15 Up 59808 58 62060 27 Te 0/16 Up 59889 1 61616 1 Te 0/17 Up
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. pre-Version 6.2.1.0 Introduced on the E-Series. If the packet includes a Layer 2 header, the difference between the link MTU and IP MTU (ip mtu command) must be enough bytes to include the Layer 2 header. When you enter the no mtu command, Dell Networking OS reduces the IP MTU value to 1536 bytes. Link MTU and IP MTU considerations for port channels and VLANs are as follows.
To return a port to accept either tagged or untagged frames (non-hybrid), use the no portmode hybrid command. Defaults non-hybrid Command Modes INTERFACE (conf-if-interface-slot/port) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
802.1QTagged: Hybrid Vlan membership: Vlan 10, Vlan 20 Native VlanId: 10 Dell(conf-if-vl-20)# Example (Vlan) Dell(conf-if-vl-20)#interface vlan 10 Dell(conf-if-vl-10)#no untagged tengigabitethernet 7/1 Dell(conf-if-vl-10)#interface vlan 20 Dell(conf-if-vl-20)#no tagged tengigabitethernet 7/1 Dell(conf-if-vl-20)#interface tengigabitethernet 7/1 Dell(conf-if-gi-7/0)#no portmode hybrid Dell(conf-if-vl-20)# rate-interval Configure the traffic sampling interval on the selected interface.
Related Commands show interfaces — displays information on physical and virtual interfaces. show config Display the interface configuration. S4820T Syntax show config Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.0.2.
Example Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
• Command History Usage Information EXEC Privilege Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2(0.2) Added support for the tunnel interface type. 9.1(0.0) Updated Management Ethernet output to include two global IPv6 addresses on S4810 and Z9000 and added output example showing OpenFlow instance ID. 8.3.12.1 Updated command output to support multiple IPv6 addresses on S4810. 8.3.11.4 Output expanded to support eSR4 optics in Z9000. 8.3.11.
Line Description • Unknown, Non-qualified — if wavelength is reading error, and F10 ID is not present Dell Networking allows unsupported SFP and XFP transceivers to be used, but Dell Networking OS might not be able to retrieve some data about them. In that case, typically when the output of this field is “Pluggable media present, Media type is unknown”, the Medium and the XFP/SFP receive power reading data might not be present in the output. Interface index...
Line Description – throttles = packets containing PAUSE frames – discarded = number of packets discarded without any processing – collisions = number of packet collisions – wred=count both packets discarded in the MAC and in the hardware-based queues Rate information... Estimate of the input and output traffic rate over a designated interval (30 to 299 seconds). Traffic rate is displayed in bits, packets per second, and percent of line rate. Time since...
Last clearing of "show interface" counters 1w0d5h Queueing strategy: fifo Input Statistics: 0 packets, 0 bytes 0 Vlans 0 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts 0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts 0 Multicasts, 0 Broadcasts 0 runts, 0 giants, 0 throttles 0 CRC, 0 overrun, 0 discarded Output Statistics: 0 packets, 0 bytes, 0 underruns 0 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts 0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts 0 Mult
Virtual-IP is not set Virtual-IP IPv6 address is not set MTU 1554 bytes, IP MTU 1500 bytes LineSpeed 1000 Mbit, Mode full duplex ARP type: ARPA, ARP Timeout 04:00:00 Last clearing of "show interface" counters 00:06:14 Queueing strategy: fifo Input 791 packets, 62913 bytes, 775 multicast Received 0 errors, 0 discarded Output 21 packets, 3300 bytes, 20 multicast Output 0 errors, 0 invalid protocol Time since last interface status change: 00:06:03 Example (OpenFlow instance) Dell#show interfaces vlan 6 Vlan 6
show interfaces configured Display any interface with a non-default configuration. S4820T Syntax show interfaces configured Command Modes Command History • EXEC • EXEC Privilege Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series.
show interfaces dampening Display interface dampening information. S4820T Syntax Parameters show interfaces dampening [[interface] [summary] [detail]] interface (Optional) Enter one of the following keywords and slot/port or number information: • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Te 3/10 Dell# Related Commands Up 0 0 5 750 2500 20 dampening — configures dampening on an interface. show interfaces — displays information on a specific physical interface or virtual interface. show interfaces configured — displays any interface with a non-default configuration. show interfaces phy Display auto-negotiation and link partner information.
AutoNegotiation Expansion ParallelDetectionFault is the handshaking scheme in which the link partner continuously transmit an “idle” data packet using the Fast Ethernet MLT-3 waveform. Equipment that does not support auto-negotiation must be configured to exactly match the mode of operation as the link partner or else no link can be established. 1000Base-T Control 1000Base-T requires auto-negotiation.
10MegFullDplx: False 10MegHalfDplx: False Asym Pause: False Sym Pause: False AutoNegotiation Expansion: ParallelDetectionFault: False ... Related Commands show interfaces — displays information on a specific physical interface or virtual interface. show interfaces stack-unit Display information on all interfaces on a specific S-Series or Z-Series stack member.
Output Statistics: 0 packets, 0 bytes, 0 underruns 0 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts 0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts 0 Multicasts, 0 Broadcasts, 0 Unicasts 0 throttles, 0 discarded, 0 collisions Rate info (interval 299 seconds): Input 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate Output 00.00 Mbits/sec, 0 packets/sec, 0.
Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.
Vlan membership: Vlan 2 --More-Related Commands interface — configures a physical interface on the switch. show ip interface — displays Layer 3 information about the interfaces. show interfaces — displays information on a specific physical interface or virtual interface. show interfaces transceiver — displays the physical status and operational status of an installed transceiver. The output also displays the transceiver’s serial number.
Usage Information The following describes the show interfaces transceiver command shown in the following example. Line Description Rx Power measurement type Output depends on the vendor, typically either “Average” or “OMA” (Receiver optical modulation amplitude). Temp High Alarm threshold Factory-defined setting, typically in Centigrade. Value differs between SFPs and SFP+. Voltage High Alarm threshold Displays the interface index number used by SNMP to identify the interface.
Interfaces Line Description Power Low Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. Temperature Current temperature of the SFPs. If this temperature crosses Temp High alarm/ warning thresholds, the temperature high alarm/warning flag is set to true. Voltage Current voltage of the SFPs. If this voltage crosses voltage high alarm/warning thresholds, the voltage high alarm/warning flag is set to true.
Example Line Description Tx Bias Low Alarm Flag This can be either true or false, depending on the Tx bias current value displayed above. Tx Power Low Alarm Flag This can be either true or false, depending on the Current Tx power value displayed above. Rx Power Low Alarm Flag This can be either true or false, depending on the Current Rx power value displayed above. Temperature High Warning Flag This can be either true or false, depending on the Current Temperature value displayed above.
SFP 1 Diagnostic Information =================================== SFP 1 Rx Power measurement type = Average =================================== SFP 1 Temp High Alarm threshold = 95.000C SFP 1 Voltage High Alarm threshold = 3.900V SFP 1 Bias High Alarm threshold = 17.000mA SFP 1 TX Power High Alarm threshold = 0.631mW SFP 1 RX Power High Alarm threshold = 1.259mW SFP 1 Temp Low Alarm threshold = -25.000C SFP 1 Voltage Low Alarm threshold = 2.700V SFP 1 Bias Low Alarm threshold = 1.
show interfaces vlan Display VLAN statistics. S4820T Syntax Parameters Command Modes Command History show interfaces vlan {vlan-id} [LINE] {description} vlan-id Enter the interface VLAN number. The range is from 1 to 4094. LINE (OPTIONAL) Enter the name of the VLAN. description Displays the VLAN interface information with description. • EXEC • EXEC Privilege Version Description 9.7(0.0) Introduced on the S-Series and Z-Series.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4093 VLANs on E-Series ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced.
shutdown Disable an interface. S4820T Syntax shutdown To activate an interface, use the no shutdown command. Defaults The interface is disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
speed (for 10/100/1000 interfaces) Set the speed for 10/100/1000 Base-T Ethernet interfaces. Set both sides of a link to the same speed (10/100/1000) or to auto or the link may not come up. S4820T Syntax speed {10 | 100 | 1000 | auto} To return to the default setting, use the no speed {10 | 100 | 1000} command. Parameters 10 Enter the keyword 10 to set the interface’s speed to 10 Mb/s. NOTE: This interface speed is not supported on the LC-EH-GE-50P or the LC-EJ-GE-50P card.
Usage Information This command is found on the 10/100/1000 Base-T Ethernet interfaces. When you enable auto, the system performs an automatic discovery to determine the optics installed and configure the appropriate speed. When you configure a speed for the 10/100/1000 interface, confirm the negotiation auto command setting. Both sides of the link must have auto-negotiation either enabled or disabled.
Version Description 7.5.1.0 Introduced on the C-Series. pre-Version 6.2.1.0 Introduced on the E-Series. Usage Information This command is found on the Management interface only. Related Commands interface ManagementEthernet — configures the Management port on the system (either the Primary or Standby RPM). duplex (10/100 Interfaces) — configures duplex mode on physical interfaces with the speed set to 10/100.
The system must be reloaded after issuing the CLI for the change to take effect. This command cannot be used if LR4 optics are inserted on the 40G interface. Example (stack unit – Warning message when 13 ports are configured in any port range) Dell(conf)#stack-unit 0 port 48 portmode quad Maximum number of ports that can be made Quad mode in the range <0-63> is configured. Ports 52,56,60, will be disabled on reload.
Usage Information Version Description 8.4.1.0 Added support for port-channel interfaces (the port-channel number option). 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Added the backup interface option. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-Version 6.2.1.0 Introduced on the E-Series. If an IP address or VRRP group is assigned to the interface, you cannot use the switchport command on the interface.
all • For Telnet, enter the keyword telnet. • For TFTP, enter the keyword tftp. Configure all applications. Defaults None. Command Modes EIS Mode (conf-mgmt-eis) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.2.(0.0) Introduced on the Z9000, S4810, and S4820T.
clear management application pkt-cntr Clear management application packet counters for all management application types. S4820T Syntax clear management application pkt-cntr Defaults None. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.2.(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. show ip management-eis-route Display the management routes used by EIS. S4820T Syntax show ip management-eis-route Defaults None.
ftp ntp radius sflow-collector snmp ssh syslog tacacs telnet tftp : : : : : : : : : : 0 0 0 0 0 0 0 0 0 0 show management application pkt-fallback-cntr Display the number of packets for each application type that have been rerouted to the default routing table due to management port or route lookup failure. S4820T Syntax show management application pkt—fallback-cntr Defaults None. Command Modes EXEC Privilege Command History This guide is platform-specific.
NOTE: The Dell Networking OS implementation of LAG or Port Channel requires that you configure a LAG on both switches manually. For information about Dell Networking OS link aggregation control protocol (LACP) for dynamic LAGs, refer to the Link Aggregation Control Protocol (LACP) chapter. For more information about configuring and using Port Channels, refer to the Dell Networking OS Configuration Guide. channel-member Add an interface to the Port Channel, while in INTERFACE PORTCHANNEL mode.
You cannot add an interface to a Port Channel if the interface contains an IP address in its configuration. Only the shutdown, description, mtu, and ip mtu commands can be configured on an interface if it is added to a Port Channel. The mtu and ip mtu commands are only available when the chassis is in Jumbo mode. Link MTU and IP MTU considerations for Port Channels are: • All members must have the same link MTU value and the same IP MTU value.
Command Modes PORT-CHANNEL FAILOVER-GROUP (conf-po-failover-grp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.
Usage Information Version Description Version 8.1.1.0 Introduced on E-Series ExaScale. Version 7.6.1.0 Introduced on S-Series. Version 7.5.1.0 Introduced on C-Series. pre-Version 6.2.1.0 Introduced on E-Series. Port Channel interfaces are logical interfaces and can be either in Layer 2 mode (by using the switchport command) or Layer 3 mode (by configuring an IP address). You can add a Port Channel in Layer 2 mode to a VLAN.
Defaults 1 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. Usage Information This feature groups two LAGs to work in tandem as a supergroup. For example, if one LAG goes down, the other LAG is taken down automatically, providing an alternate path to reroute traffic, avoiding oversubscription on the other LAG. You can use both static and dynamic (LACP) LAGs to configure failover groups.
Parameters Command Modes Command History channel-number For a Port Channel interface, enter the keyword port-channel then a number. For the C-Series and S-Series, the range is from 1 to 128. brief (OPTIONAL) Enter the keyword brief to display only the port channel number, the state of the port channel, and the number of interfaces in the port channel. • EXEC • EXEC Privilege This guide is platform-specific.
Example Field Description Queueing strategy. States the packet queuing strategy. FIFO means first in first out. packets input... Displays the number of packets and bytes into the interface. Input 0 IP packets... Displays the number of packets with IP headers, VLAN tagged headers, and MPLS headers. The number of packets may not add correctly because a VLAN tagged IP packet counts as both a VLAN packet and an IP packet. 0 64-byte...
Field Example Description • down — if the port channel is disabled (shutdown) • up — if the port channel is enabled (no shutdown) Uptime Displays the age of the port channel in hours:minutes:seconds. Ports Lists the interfaces assigned to this port channel. (untitled) Displays the status of the physical interfaces (up or down). • In Layer 2 port channels, an * (asterisk) indicates which interface is the primary port of the port channel. The primary port sends out interface PDU.
destination-port number Enter the keywords destination-port then the destination port number. The range is from 1 to 65536. The default is None. source-mac address Enter the keywords source-mac then the MAC source address in the nn:nn:nn:nn:nn:nn format. destination-mac address Enter the keywords destination-mac then the MAC destination address in the nn:nn:nn:nn:nn:nn format. vlan vlan-id Enter the keywords vlan then the VLAN-id. The range is from 0 to 4094.
Egress Port for port-channel 1, for the given flow, is Te 13/2 Time Domain Reflectometer (TDR) TDR is useful for troubleshooting an interface that is not establishing a link; either it is flapping or not coming up at all. TDR detects open or short conditions of copper cables on 100/1000 Base-T modules. Important Points to Remember • The interface and port must be enabled (configured—refer to the interface command) before running TDR. An error message is generated if you have not enabled the interface.
Usage Information The interface must be enabled to run the test or an error message is generated: Dell#tdr-cable-test tengigabitethernet 11/1 % Error: Interface is disabled Te 11/1. Syslog messages are generated when the link flaps during TDR tests. Related Commands show tdr — displays the results of the TDR test. show tdr Display the TDR test results.
Status Definition Length: 93 (+/- 1) meters, Status: Open An opening is detected on the cable. The location, in this Example is 93 meters. The open is accurate to plus or minus one meter. Status: Impedance Mismatch There is an impedance mismatch in the cables.
Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Pre-version 8.3.7.0 Introduced on the E-Series ExaScale. Dell#debug ip udp-helper UDP helper debugging is on 01:20:22: Pkt rcvd on Gi 5/0 with IP DA (0xffffffff) will be sent on Gi 5/1 Gi 5/2 Vlan 3 01:44:54: Pkt rcvd on Gi 7/0 is handed over for DHCP processing. Related Commands ip udp-broadcast-address — configures a UDP IP address for broadcast.
show ip udp-helper — displays the configured UDP helpers on all interfaces. ip udp-helper udp-port Enable the UDP broadcast feature on an interface either for all UDP ports or a specified list of UDP ports. S4820T Syntax ip udp-helper udp-port [udp-port-list] To disable the UDP broadcast on a port, use the no ip udp-helper udp-port [udp-port-list] command. Parameters udp-port-list (OPTIONAL) Enter up to 16 comma-separated UDP port numbers.
show ip udp-helper Display the configured UDP helpers on all interfaces. S4820T Syntax show ip udp-helper Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
ip http source-interface Specify an interface as the source interface for HTTP connections. This feature is supported on S4820T platform. Syntax ip http source-interface interface To delete an interface, use theno ip http source-interface interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
25 Internet Protocol Security (IPSec) Internet protocol security (IPSec) is an end-to-end security scheme for securing IP communications by authenticating and encrypting all packets in a session. Use IPSec between hosts, gateways, or hosts and gateways. IPSec uses a series of protocol functions to achieve information security: • Authentication Headers (AH) — Connectionless integrity and origin authentication for IP packets.
esp-authentication esp-encryption • md5 — Use Message Digest 5 (MD5) authentication. • sha1 — Use Secure Hash Algorithm 1 (SHA-1) authentication. • null — Causes an encryption policy configured for the area to not be inherited on the interface. Enter the keywords esp-authentication then the transform type of operation to apply to traffic. The transform type represents the encryption or authentication applied to traffic. • md5 — Use Message Digest 5 (MD5) authentication.
crypto ipsec policy Create a crypto policy used by ipsec. S4820T Syntax crypto ipsec policy name seq-num ipsec-manual To delete a crypto policy entry, use the no crypto ipsec policy name seq-num ipsec-manual command. Parameters name Enter the name for the crypto policy set. seq-num Enter the sequence number assigned to the crypto policy entry. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. match Apply an match filter to the crypto policy.
match match match match 4 5 6 7 tcp tcp tcp tcp 1.1.1.1 1.1.1.1 1.1.1.1 1.1.1.1 /32 /32 /32 /32 0 1.1.1.2 /32 23 23 1.1.1.2 /32 0 0 1.1.1.2 /32 21 21 1.1.1.2 /32 0 session-key Specify the session keys used in the crypto policy entry. S4820T Syntax session-key {inbound | outbound} {ah spi hex-key-string | esp spi encrypt hex-key-string auth hex-key-string To delete the session key information from the crypto policy, use the no session-key {inbound | outbound} {ah | esp} command.
show crypto ipsec transform-set Display the transform set configuration. S4820T Syntax Parameters show crypto ipsec transform-set name name Enter the name of the transform set. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.2(0.
Inbound AH SPI : Inbound ESP Auth SPI : Inbound ESP Encry SPI : Inbound AH Key : Inbound ESP Auth Key : Inbound ESP Encry Key : Outbound AH SPI : Outbound ESP Auth SPI : Outbound ESP Encry SPI: Outound AH Key : Outound ESP Auth Key : Outound ESP Encry Key : Match sequence Num Protocol type IP or IPv6 Source address Source mask Source port Destination address Destination mask Destination port source-interface name source-interface num 0 0 0 [0]:: [0]:: [0]:: 0 0 0 [0]:: [0]:: [0]:: : : : : : : : : : : : 2
26 IPv4 Routing The basic IPv4 commands are supported by Dell Networking operating system on the S4820T platform. arp To associate an IP address with a MAC address in the switch, use address resolution protocol (ARP). S4820T Syntax arp [vrf vrf-name] ip-address mac-address interface To remove an ARP address, use the no arp ip-address command. Parameters vrf vrf-name Enter a VRF name to configure an ARP entry for that VRF.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. You cannot use Class D or Class E IP addresses or zero IP address (0.0.0.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810. Usage Information This timer is an exponential backoff timer. Over the specified period, the time between ARP requests increases. This behavior reduces the potential for the system to slow down while waiting for a multitude of ARP responses. Related Commands show arp retries — displays the configured number of ARP retries.
arp max-entries Enables you to configure the maximum number of ARP entries per VRF that are allowed for IPv4.. S4820T Syntax arp max-entries [vrf vrf-name] max-number Parameters vrf vrf-name Enter the name of a specific VRF for which you want to configure maximum number of ARP entries that IPv4 allows. max-number Enter the maximum number of ARP entries that a VRF RTM can hold. The range is from 0 to 65535. Defaults Not configured.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced. Usage Information Retries are 20 seconds apart. Related Commands show arp retries — displays the configured number of ARP retries. arp timeout Set the time interval for an ARP entry to remain in the ARP cache. S4820T Syntax Parameters arp timeout minutes minutes Enter the number of minutes.
clear arp-cache Clear the dynamic ARP entries from a specific interface or optionally delete (no-refresh) ARP entries from the content addressable memory (CAM). S4820T Syntax clear arp-cache [vrf vrf-name | interface | ip ip-address] [no-refresh] Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to clear the ARP cache corresponding to that VRF.
Version Description 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. clear host Remove one or all dynamically learned host table entries. S4820T Syntax Parameters clear host name name Enter the name of the host to delete.
Parameters unit-number Enter the number of the stack unit. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to clear all FIB entries corresponding to that VRF. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.
Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.10 Introduced on the E-Series. Example Dell#debug ip dhcp 00:12:21 : %RELAY-I-PACKET: BOOTP REQUEST (Unicast) received at interface 113.3.3.17 BOOTP Request, hops = 0, XID = 0xbf05140f, secs = 0, hwaddr = 00:60:CF:20:7B:8C, giaddr = 0.0.0.0 00:12:21 : %RELAY-I-BOOTREQUEST: Forwarded BOOTREQUEST for 00:60:CF:20:7B: 8C to 14.
debug ip icmp View information on the internal control message protocol (ICMP). S4820T Syntax debug ip icmp [interface] [count value] To disable debugging, use the no debug ip icmp command. Parameters interface count value (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
ICMP: ICMP: ICMP: ICMP: ICMP: ICMP: Usage Information src 40.40.40.40, dst 40.40.40.40, echo reply echo request sent to dst 40.40.40.40 echo request rcvd from src 40.40.40.40 src 40.40.40.40, dst 40.40.40.40, echo reply src 40.40.40.40, dst 40.40.40.40, echo reply echo request sent to dst 40.40.40.40 To stop packets from flooding the user terminal when debugging is turned on, use the count option. debug ip packet View a log of IP packets sent and received.
Usage Information Example Version Description 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Added the access-group option. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Added the count option.
IP: s=40.40.40.40 (local), d=224.0.0.6 (Gi 4/11), len 28, sending broad/ multicast proto=2 IP: s=0.0.0.0, d=30.30.30.30, len 100, unroutable ICMP type=8, code=0 IP: s=0.0.0.0, d=30.30.30.30, len 100, unroutable ICMP type=8, code=0 Usage Information To stop packets from flooding the user terminal when debugging is turned on, use the count option. The access-group option supports only the equal to (eq) operator in TCP ACL rules.
Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. ip domain-list Configure names to complete unqualified host names. S4820T Syntax ip domain-list name To remove the name, use the no ip domain-list name command. Parameters name Enter a domain name to be used to complete unqualified names (that is, incomplete domain names that cannot be resolved). Defaults Disabled.
• specify a domain name server with the ip name-server command • enable DNS with the ip domain-lookup command To view current bindings, use the show hosts command. To view a DNS-related configuration, use the show running-config resolve command. Related Commands ip domain-name — specifies a DNS server. ip domain-lookup To address resolution (that is, DNS), enable dynamic host-name. S4820T Syntax ip domain-lookup To disable DNS lookup, use the no ip domain-lookup command. Defaults Disabled.
ip domain-name Configure one domain name for the switch. S4820T Syntax ip domain-name name To remove the domain name, use the no ip domain-name command. Parameters name Enter one domain name to be used to complete unqualified names (that is, incomplete domain names that cannot be resolved). Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
ip helper-address Specify the address of a DHCP server so that DHCP broadcast messages can be forwarded when the DHCP server is not on the same subnet as the client. S4820T Syntax ip helper-address ip-address To remove a DHCP server address, use the no ip helper-address command. Parameters ip-address Enter an IP address in dotted decimal format (A.B.C.D). Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific.
ip helper-address hop-count disable Disable the hop-count increment for the DHCP relay agent. S4820T Syntax ip helper-address hop-count disable To re-enable the hop-count increment, use the no ip helper-address hop-count disable command. Defaults Enabled; the hops field in the DHCP message header is incremented by default. Command Modes CONFIGURATION Command History This guide is platform-specific.
To remove an IP host, use the no ip host name [ip-address] command. Parameters name Enter a text string to associate with one IP address. ip address Enter an IP address, in dotted decimal format, to be mapped to the name. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Not configured. Command Modes CONFIGURATION Command History Usage Information • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.
NOTE: When you configure the capability to enable the loopback IP address to be sent for easy debugging and diagnosis (IP addresses of the devices for which the ICMP source interface is configured), the source IP address of the outgoing ICMP error message is modified, although the packets are not sent out using the configured interface.
ip max-frag-count Set the maximum number of fragments allowed in one packet for packet re-assembly. S4820T Syntax ip max-frag-count count To place no limit on the number of fragments allowed, use the no ip max-frag-count command. Parameters count Enter a number for the number of fragments allowed for re-assembly. The range is from 2 to 256. Defaults No limit is set on number of fragments allowed. Command Modes CONFIGURATION Command History This guide is platform-specific.
max-number Enter the maximum number of protocol routes that a VRF RTM can hold. The range is from 0 to 7500. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version 9.4.(0.0) Introduced on the S4810 and S4820T.
Usage Information When you enter the no mtu command, Dell Networking OS reduces the ip mtu value to 1536 bytes. To return the IP MTU value to the default, use the no ip mtu command. Starting with Dell Networking OS Release 9.2(0.2), the ip mtu command is not supported to configure the IP MTU value that is used when the IP packet is fragmented. Instead of having to configure the IP MTU value, this value is automatically computed by the software when you configure an interface.
ip name-server Enter up to six IPv4 addresses of name servers. The order you enter the addresses determines the order of their use. S4820T Syntax ip name-server ipv4-address [ipv4-address2...ipv4-address6] To remove a name server, use the no ip name-server ip-address command. Parameters ipv4-address Enter the IPv4 address, in dotted decimal format, of the name server to be used. ipv4-address2...
To disable proxy ARP, use the no ip proxy-arp command. Defaults Enabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For the Management interface on the stack-unit, enter the keyword ManagementEthernet then the slot/port information. The slot range is from 0 to 1. The port range is 0.
Usage Information Version Description 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Added support for tunnel interface type. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.
1.1.1.0/24 4.4.4.2 weight 100 ip route vrf test 200 Related Commands 1.1.1.0/24 6.6.6.2 weight show ip route — views the switch routing table. ip source-route Enable Dell Networking OS to forward IP packets with source route information in the header. S4820T Syntax ip source-route To drop packets with source route information, use the no ip route-source command. Defaults Enabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Parameters Command Modes Command History Usage Information <8-75> Wait duration in seconds for the TCP connection to be established. CONFIGURATION Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810, S4820T, S6000, and Z9000 platforms. You can configure the amount of time for which the device must wait before it attempts to establish a TCP connection. Using this capability, you can limit the wait times for TCP connection requests.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
• tcp-udp enable Enter the keywords to distribute traffic based on the following: • ingress-port enable source-mac — Uses the source MAC address, VLAN, Ethertype, source module ID and source port ID fields to hash. The hashing mechanism returns a 3-bit index indicating which port the packet should be forwarded. enable — Takes the TCP/UDP source and destination ports into consideration when doing hash computations. This option is enabled by default.
mac [source-mac | source-port-id | source-module-id | dest-mac | dest-portid | dest-module-id | vlan | ethertype | source-dest-mac ] | tunnel [ipv4over-ipv4 | ipv4-over-gre-ipv4 | mac-in-mac]} Parameters {{ip-selection| ipv6selection [source-ip | source-ipv6 | source-port-id | source-module-id | dest-ip | dest-ipv6 | dest-port-id | destmodule-id | protocol | vlan | L4-sourceport | L4-destport ] mac [source-mac | source-port-id | source-module-id | dest-mac | destport-id | destmodule-id | vlan | ethertype
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Added support for IPv6. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. management route Configure a static route that points to the Management interface or a forwarding router.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for forty gigabit, vlan, and tengigabit ethernet interfaces. Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000 and added support for IPv6. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.
• For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. ip ip-address mask (OPTIONAL) Enter the keyword ip then an IP address in the dotted decimal format. Enter the optional IP address mask in the slash prefix format (/ x).
Usage Information Version Description pre-6.1.1.0 Introduced on the E-Series. The following example shows two VLANs that are associated with a private VLAN (PVLAN) (refer to Private VLAN (PVLAN)). If you have entered the clear arp-cache command to remove a large number of ARP entries and the command is still being processed in the background, an error message display if you attempt to enter the show arp command: Clear arp in-progress.
Description Total Entries Lists the total number of ARP entries in the ARP table. Static Entries Lists the total number of configured or static ARP entries. Dynamic Entries Lists the total number of learned or dynamic ARP entries. CPU Lists which CPU the entries are stored on.
show hosts View the host table and DNS configuration. S4820T Syntax Command Modes Command History show hosts • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.
Field Description • Example ?? — the entry is suspect. TTL Displays the amount of time until the entry ages out of the cache. For dynamically learned entries only. Type Displays IP as the type of entry. Address Displays the IP addresses assigned to the host.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version 8.3.19.0 Introduced on the S4820T. Version 8.3.7.0 Introduced on the S4810. Version 8.1.1.2 Introduced on the E-Series ExaScale E600i. Version 8.1.1.0 Introduced on the E-Series ExaScale.
3280 11144 11145 11146 11147 11148 65535 Dell# Usage Information 2.2.2.2 6.6.6.0 5.5.5.0 4.4.4.0 3.3.3.0 2.2.2.0 0.0.0.0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.
show ip cam stack-unit Display CAM entries for a port-pipe of a stack-unit on a S-Series or Z-Series switch. Syntax Parameters show ip cam stack-unit {stack-unit-number} [port-set {pipe-number} | vrf vrf-name {i address mask [longer-prefixes [ecmp-group detail]]}| ecmp-group {detail | member-inf [detail [group-index index-number]]}| summary] stack-unit-number Enter the stack-unit ID. port-set pipenumber Enter the keyword port-set then the number of the stack unit’s port-pipe. The unit ID range is to 0.
Example Field Description Destination Displays the destination route of the index. EC Displays 1 if the route is an ECMP route. Else, displays 0. C This is the CPU bit. If it displays 1, then it indicates that a packet hitting this entry will be forwarde CPU. V Id Displays the VLAN ID. If the entry is 0, the entry is not part of a VLAN. Mac Addr Displays the next-hop router’s MAC address. Port Displays the egress interface.
show ip fib linecard View all forwarding information base (FIB) entries. S4820T Syntax Parameters Command Modes Command History show ip fib linecard slot-number [vrf vrf instance | ip-address/prefix-list | summary] vrf instance (OPTIONAL) E-Series Only: Enter the keyword vrf then the VRF instance name to show the FIB cache entries tied to that VRF instance. slot-number Enter the number of the line card slot.
Example Field Description EC Displays the number of ECMP paths. Dell>show ip fib linecard 12 Destination Gateway First-Hop Mac-Addr Port VId Index EC -------------------------------------------------------------------------------3.0.0.0/8 via 100.10.10.10, So 2/8 100.10.10.10 00:01:e8:00:03:ff So 2/8 0 60260 0 3.0.0.0/8 via 101.10.10.10, So 2/9 00.10.10.0/24 Direct, So 2/8 0.0.0.0 00:01:e8:00:03:ff So 2/8 0 11144 0 100.10.10.1/32 via 127.0.0.1 127.0.0.1 00:00:00:00:00:00 CP 0 3276 0 100.10.10.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Added support for up to seven stack members. 7.6.1.0 Introduced on the S-Series. The following describes the show ip fib stack-unit command shown in the following example. Field Description Destination Lists the destination IP address.
Related Commands clear ip fib stack-unit — clear FIB entries on a specified stack-unit. ip ecmp weighted— enables weighted ECMP calculations. show ip flow Show how a Layer 3 packet is forwarded when it arrives at a particular interface. S4820T Syntax show ip flow interface interface {source-ip address destination-ip address} {protocol number [tcp | udp]} {src-port number destination-port number} Parameters interface interface Enter the keyword interface then one of the following interface keywords.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. This command provides egress port information for a given IP flow. This information is useful in identifying which interface the packet follows in the case of Port-channel and Equal Cost Multi Paths. Use this command for routed packed only. For switched packets, use the show port-channel-flow command.
Command Modes Command History brief (OPTIONAL) Enter the keyword brief to view a brief summary of the interfaces and whether an IP address is assigned. configured (OPTIONAL) Enter the keyword configured to display the physical interfaces with non-default configurations only. • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Dell#show ip int te 1/1 TenGigabitEthernet 1/1 is down, line protocol is down Internet address is not set IP MTU is 1500 bytes Inbound access list is not set Proxy ARP is enabled Split Horizon is enabled Poison Reverse is disabled ICMP redirects are not sent ICMP unreachables are not sent Dell# Usage Information Example (Brief) The following describes the show ip interface brief command shown in the following example.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.4.1.0 Introduced on the C- and E-Series. 8.3.7.0 Introduced on the S4810.
Example Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Dell#show ip protocols Routing Protocol is "bgp 1" Cluster Id is set to 20.20.20.3 Router Id is set to 20.20.20.
Command Modes Command History • If you enter isis, you can include the ISIS routing-tag. • If you enter ospf, you can include the OSPF process-id. process-id (OPTIONAL) Specify that only OSPF routes with a certain process ID must be displayed. routing-tag (OPTIONAL) Specify that only ISIS routes with a certain routing tag must be displayed. connected (OPTIONAL) Enter the keyword connected to view only the directly connected routes.
Field Description • B = BGP • IN = internal BGP • EX = external BGP • LO = Locally Originated • O = OSPF • IA = OSPF inter area • N1 = OSPF NSSA external type 1 • N2 = OSPF NSSA external type 2 • E1 = OSPF external type 1 • E2 = OSPF external type 2 • i = IS-IS • L1 = IS-IS level-1 • L2 = IS-IS level-2 • IA = IS-IS inter-area • * = candidate default • > = non-active route • + = summary routes Destination Identifies the route’s destination IP address Gateway Identifies w
Example (Summary) Dell#show ip route summary Route Source Active Routes Non-active Routes connected 2 0 static 1 0 Total 3 0 Total 3 active route(s) using 612 bytes R1_E600i>show ip route static ? | Pipe through a command R1_E600i>show ip route static Destination Gateway Dist/Metric Last Change ----------- ------- ----------- ----------*S 0.0.0.0/0 via 10.10.91.
* 6.6.6.2, via TenGigabitEthernet 1/16 weight 200 Dell(conf)# Example (With Weighted ECMP Disabled) Dell(conf)#ip route 1.1.1.0/24 6.6.6.2 weight 100 Dell(conf)#ip route 1.1.1.0/24 6.6.6.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
show ip traffic View IP, ICMP, UDP, TCP and ARP traffic statistics. S4820T Syntax show ip traffic [all | cp | rp1 | rp2] NOTE: These options are supported only on the E-Series. Parameters all (OPTIONAL) Enter the keyword all to view statistics from all processors. If you do not enter a keyword, you also view all statistics from all processors. cp (OPTIONAL) Enter the keyword cp to view only statistics from the Control Processor.
Keyword Definition • route not found for unicast/multicast; ingress interfaces do not belong to the destination multicast group • destination IP address belongs to reserved prefixes; the host/network is unreachable bad options... Unrecognized IP option on a received packet. Frags: IP fragments received. ... reassembled Number of IP fragments that were reassembled. ... timeouts Number of times a timer expired on a reassembled queue. ... too big Number of invalid IP fragments received. ...
0 parameter, 0 timestamp, 0 info request, 0 other Sent: 0 redirects, 0 unreachable, 0 echo, 0 echo reply 0 mask requests, 0 mask replies, 0 quench, 0 timestamp 0 info reply, 0 time exceeded, 0 parameter problem UDP statistics: Rcvd: 0 total, 0 checksum errors, 0 no port 0 short packets, 0 bad length, 0 no port broadcasts, 0 socket full Sent: 0 total, 0 forwarded broadcasts TCP statistics: Rcvd: 23829 total, 0 checksum errors, 0 no port Sent: 16048 total ARP statistics: Rcvd: 156 requests, 11 replies Sent: 2
Field Description • 0 checksum error... Example no port = number of packets received with no designated port Displays the number of packets received with the following: • checksum errors • bad offset to data • too short 329 packets... Displays the number of packets and bytes received in sequence. 17 dup... Displays the number of duplicate packets and bytes received. 0 partially... Displays the number of partially duplicated packets and bytes received. 7 out-of-order...
0 checksum error, 0 bad offset, 0 too short 329 packets (1263 bytes) in sequence 17 dup packets (6 bytes) 0 partially dup packets (0 bytes) 7 out-of-order packets (0 bytes) 0 packets ( 0 bytes) with data after window 0 packets after close 0 window probe packets, 41 window update packets 41 dup ack packets, 0 ack packets with unsend data 10184 ack packets (12439508 bytes) Sent: 12007 Total, 0 urgent packets 25 control packets (including 24 retransmitted) 11603 data packets (12439677 bytes) 24 data packets (7
27 IPv6 Access Control Lists (IPv6 ACLs) IPv6 ACLs and IPv6 Route Map commands are supported on Dell Networking S4820T platform. NOTE: For IPv4 ACL commands, refer to the Access Control Lists (ACL) chapter. Important Points to Remember • Certain platforms require manual CAM usage space allotment. For more information, refer to the cam-acl command. • Egress IPv6 ACL and IPv6 ACL on the Loopback interface is not supported. • Reference to an empty ACL permits any traffic.
Example Version Description 8.3.7.0 Introduced on the S4810. 8.4.2.1 Introduced on the S-Series. 8.4.2.0 Introduced on the E-Series TeraScale. 7.8.1.0 Introduced on the C-Series. Dell#show cam-acl-egress -- Chassis Egress Cam ACL -Current Settings(in block sizes) L2Acl : 1 Ipv4Acl : 1 Ipv6Acl : 2 -- Stack unit 0 -Current Settings(in block sizes) L2Acl : 1 Ipv4Acl : 1 Ipv6Acl : 2 Dell#show cam-acl Related Commands cam-acl — configures CAM profiles to support IPv6 ACLs.
Example Version Description 7.8.1.0 Introduced on the C-Series.
L2Qos : 3 Dell#show cam-acl Related Commands cam-acl — configures CAM profiles to support IPv6 ACLs. permit icmp To allow all or specific internet control message protocol (ICMP) messages, configure a filter.
permit To configure a filter that matches the filter criteria, select an IPv6 protocol number, ICMP, IPv6, TCP, or UDP. Syntax permit {ipv6-protocol-number | icmp | ipv6 | tcp | udp} To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command syntax if you know the filter’s sequence number • Use the no permit {ipv6-protocol-number | icmp | ipv6 | tcp | udp} command ip-protocol-number Enter an IPv6 protocol number. The range is from 0 to 255.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. ipv6 access-list Configure an access list based on IPv6 addresses or protocols. S4820T Syntax ipv6 access-list access-list-name cpu-qos {permit | deny} ospfv3 To delete an access list, use the no ipv6 access-list access-list-name command.
Usage Information Version Description 8.4.2.1 Introduced on the S-Series. 8.2.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series. Increased the name string to accept up to 140 characters. Prior to version 7.8.1.0, names are up to 16 characters long. 7.4.1.0 Introduced on the E-Series TeraScale. The number of entries allowed per ACL is hardware-dependent. For detailed specification on entries allowed per ACL, refer to your line card documentation.
Usage Information For the new settings to take effect, save the new CAM settings to the startup-config (write-mem or copy run start), then reload the system. The total amount of space allowed is 4 FP Blocks.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.4.2.0 Introduced on the E-Series TeraScale. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series. For the new settings to take effect, save the new CAM settings to the startup-config (write-mem or copy run start), then reload the system. The total amount of space allowed is 16 FP blocks.
28 IPv6 Basics IPv6 basic commands are supported on the Dell Networking OS. NOTE: For information about the Dell Networking operating software version and platform that supports IPv6 in each software feature, refer to the IPv6 Addressing chapter of the Dell Networking OS Configuration Guide. clear ipv6 fib Clear (refresh) all forwarding information base (FIB) entries on a linecard or stack unit.
clear ipv6 route Clear (refresh) all or a specific route from the IPv6 routing table. S4820T Syntax clear ipv6 route [vrf vrf-name] {* | ipv6-address prefix-length} Parameters vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to clear the IPv6 routes corresponding to that VRF. * Enter the * to clear (refresh) all routes from the IPv6 routing table. ipv6-address prefixlength Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. maximum dynamic-routes-ipv6 Specify the maximum number of dynamic (protocol) IPv6 routes a VRF can have. S4820T Syntax maximum dynamic-routes—ipv6 limit {warn-threshold threshold-value | warningonly} To remove the limit on the maximum number of IPv6 routes used, use the no maximum dynamicroutes-ipv6 command. Parameters limit Maximum number of IPv6 routes allowed in a VRF.
ipv6 address autoconfig Configure IPv6 address auto-configuration for the management interface. S4820T Syntax ipv6 address autoconfig To disable the address autoconfig operation on the management interface, use the no ipv6 address autoconfig command. Default Disabled Command Modes INTERFACE (management interface only) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
To remove the IPv6 address, use the no ipv6 address {ipv6-address prefix-length} command. Parameters ipv6-address prefixlength Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros. Defaults none Command Modes INTERFACE Command History This guide is platform-specific.
ipv6 address eui64 Configure IPv6 EUI64 address configuration on the interface. S4820T Syntax ipv6 address {ipv6-address prefix-length} eui64 To disable IPv6 EUI64 address autoconfiguration, use the no ipv6 address {ipv6-address prefix-length} eui64 command. Parameters ipv6-address prefixlength Enter the IPv6 prefix in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros.
Parameters pps Enter the maximum number of error packets generated per second. The range is from 1 to 200, where 0 disables the rate-limiting. Default 100 pps Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.
ipv6 host Assign a name and IPv6 address the host-to-IPv6 address mapping table uses. S4820T Syntax ipv6 host name ipv6-address To remove an IP host, use the no ipv6 host name {ipv6–address}. Parameters name Enter a text string to associate with one IP address. ipv6-address Enter the IPv6 address (X:X:X:X::X) to be mapped to the name. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.1.0 Introduced on the E-Series TeraScale.
ipv6 nd dns-server Configures Recursive DNS Server (RDNSS) addresses to be distributed via IPv6 router advertisements to an IPv6 device. Syntax ipv6 nd dns-server {ipv6-RDNSS-address} {lifetime | infinite} To remove the IPv6 RDSS configuration, use no ipv6 nd dns-server {ipv6-RDNSS-address} {lifetime | infinite} Parameters ipv6-RDNSSaddress Enter the IPv6 Recursive DNS Server’s (RDNSS) address. You can specify up to 4 IPv6 RDNSS server addresses. lifetime Enter the lifetime in seconds.
no-advertise Enter the keyword no-advertise to prevent the specified prefix from being advertised. no-autoconfig Enter the keywords no-autoconfig to disable Stateless Address Autoconfiguration. no-rtr-address Enter the keyword no-rtr-address to exclude the full router address from router advertisements (the R bit is not set). off-link Enter the keywords off-link to advertise the prefix without stating to recipients that the prefix is either on-link or off-link.
To remove the IPv6 route, use the no ipv6 route [vrf vrf-name]ipv6-address prefixlength {ipv6-address | interface | interface ipv6-address} [distance] [tag value] [permanent] [weight] command. Parameters vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to install IPv6 routes in that VRF. ipv6-address prefixlength Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for VRF. Also included the weight parameter to support weighted ECMP feature. Introduced on the S6000-ON. 9.0.0.0 Introduced on the Z9000. 8.3.19.
ipv6 unicast-routing Enable IPv6 Unicast routing. S4820T Syntax ipv6 unicast-routing To disable unicast routing, use the no ipv6 unicast-routing command. Defaults Enabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.0.0.
show ipv6 cam stack-unit Displays the IPv6 CAM entries for the specified stack-unit. S4820T Syntax Parameters show ipv6 cam [vrf vrf-name] stack-unit unit-number port-set {0-1} [summary | index | ipv6 address] vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to display IPv6 CAM entries corresponding to that VRF. NOTE: If you do not specify this option, IPv6 CAM entries corresponding to the default VRF are displayed. unit-number Enter the stack unit’s ID number.
NOTE: If a route has a mask greater than 64, no output is displayed and no output is displayed for show ipv6 cam stack-unit unit-number port-set {0-1} ipv6-address, but an equivalent /64 entry would be listed in the show ipv6 cam stack-unit unit-number port-set {0-1} output.
summary (OPTIONAL) Enter the keyword summary to view a summary of entries in IPv6 cam. ipv6-address Enter the IPv6 address in the x:x:x:x::x/n format to display networks that have more specific prefixes. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros. Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. ipv6 nd dad attempts — Configure system to set the flow label field in the packets to zero. show ipv6 interface Display the status of interfaces configured for IPv6.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.2.(0.0) Added support for tunnel interface. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.5.1.
Actual address is 300::1, subnet is 300::/64 (MANUAL) Remaining lifetime: infinite Virtual-IP IPv6 address is not set Global Anycast address(es): Joined Group address(es): ff02::1 ff02::1:ff00:1 ff02::1:ffa7:497e ND MTU is 0 ICMP redirects are not sent DAD is enabled, number of DAD attempts: 3 ND reachable time is 20410 milliseconds ND base reachable time is 30000 milliseconds ND retransmit interval is 1000 milliseconds ND hop limit is 64 Dell# Example (Brief) Example (tunnel) 840 IPv6 Basics Dell#show
show ipv6 mld_host Display the IPv6 MLD host counters. S4820T Syntax show ipv6 mld_host Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
show ipv6 route Displays the IPv6 routes. S4820T Syntax show ipv6 route [ipv6-address prefix-length] [vrf vrf-name] [hostname] [all] [bgp as number] [connected] [isis tag] [list prefix-list name] [ospf process-id] [rip] [static] [summary] Parameters ipv6-address prefixlength (OPTIONAL) Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros.
Usage Information Example (S-Series) Version Description 8.2.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series TeraScale. The following describes the show ipv6 route command shown in the following examples.
C C S L Dell# ----------------------------------------------------100::/64 [0/0] Direct, Te 1/12/1, 20:00:18 400::/64 [0/0] Direct, Tu 1, 00:09:02 800::/64 [1/0] via 100::1, Te 1/12/1, 00:00:50 fe80::/10 [0/0] Direct, Nu 0, 20:00:18 Dell#show ipv6 route Codes: C - connected, L - local, S - static, R - RIP, B - BGP, IN - internal BGP, EX - external BGP,LO - Locally Originated, O - OSPF, IA - OSPF inter area, N1 - OSPF NSSA external type 1, N2 - OSPF NSSA external type 2, E1 - OSPF external type 1, E2 - OSP
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.4.2.1 Introduced on the C-Series and S-Series. 8.2.1.0 Introduced on the E-Series ExaScale. 7.4.1.0 Introduced on the E-Series TeraScale.
29 iSCSI Optimization Internet small computer system interface (iSCSI) optimization enables quality-of-service (QoS) treatment for iSCSI storage traffic on an S4820T system. To configure and verify the iSCSI optimization feature, use the following Dell Networking OS commands. advertise dcbx-app-tlv Configure DCBX to send iSCSI TLV advertisements. S4820T Syntax advertise dcbx-app-tlv iscsi To disable DCBX iSCSI TLV advertisements, use the no advertise dcbx-app-tlv iscsi command. Defaults Disabled.
To remove the iSCSI session aging time, use the no iscsi aging time command. Parameters time Enter the aging time for the iSCSI session. The range is from 5 to 43,200 minutes. Defaults 10 minutes Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 8.3.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on MXL 10/40GbE Switch IO Module. By default, iSCSI flows are assigned to dot1p priority 4.
iscsi priority-bits Configure the priority bitmap that advertises in the iSCSI application TLVs. S4820T Syntax iscsi priority-bits To remove the configured priority bitmap, use the no iscsi priority-bits command. Defaults 4 (0x10 in the bitmap) Command Modes PROTOCOL LLDP (only on the global, not on the interface) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
iscsi target port Configure the iSCSI target ports and optionally, the IP addresses on which iSCSI communication is monitored. S4820T Syntax iscsi target port [tcp-port-2...tcp-port-16]ip-address [ip-address] To remove the configured iSCSI target ports or IP addresses, use the no iscsi target port command. Parameters tcpport-2...tcpport- 16 Enter the tcp-port number of the iSCSI target ports.
The following is a list of the Dell Networking OS version history for this command. Example Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on MXL 10/40GbE Switch IO Module.
Session 1: --------------------------------------------------------Target: iqn.2001-05.com.equallogic:0-8a0906-0f60c2002-0360018428d48c94iom011 Initiator: iqn.1991-05.com.microsoft:win-x9l8v27yajg ISID: 400001370000. Usage Information Only sessions the switch observes are learned; sessions flowing through an adjacent switch are not learned. After the switch is reloaded, any information exchanged during the initial handshake is not available.
Session 1 : ---------------------------------------------------Target:iqn.2010-11.com.ixia:ixload:iscsi-TG1 Initiator:iqn.2010-11.com.ixia.ixload:initiator-iscsi-35 Up Time:00:00:01:22(DD:HH:MM:SS) Time for aging out:00:00:09:31(DD:HH:MM:SS) ISID:806978696102 Initiator Initiator Target Target Connection IP Address TCP Port IP Address TCPPort ID 10.10.0.53 33432 10.10.0.101 3260 0 Related Commands • show iscsi — displays the currently configured iSCSI settings.
30 Intermediate System to Intermediate System (ISIS) The intermediate system to intermediate system (IS-IS) protocol for IPv4 and IPv6 is supported on the S4820T platform. IS-IS is an interior gateway protocol that uses a shortest-path-first algorithm. IS-IS facilitates the communication between open systems, supporting routers passing both IP and OSI traffic. A router is considered an intermediate system. Networks are partitioned into manageable routing domains, called areas.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Introduced on the E-Series. To perform protocol-support consistency checks on hello packets, use this command. The adjacency-check is enabled by default. If a BFD session goes down indicating that IPv4 or IPv6 connectivity to its neighbor is lost, it does not imply that the adjacency is lost altogether. The hello adjacency runs over Layer 2, and does not require IP connectivity.
Usage Information Version Description 7.5.1.0 Added IPv6 ISIS support. 6.3.1.0 Version 6.3.1.0 Introduced You cannot disable leaking from Level 1 to Level 2. Also, you cannot enable leaking from Level 2 to Level 1. However, you can regulate the rate flow from one level to another using an IP Prefix list. If you do not configure the IP Prefix list, all Level 1 routes are leaked. You can find more information in IETF RFC 2966, Domain-wide Prefix Distribution with Two-Level IS-IS.
• isis password — allows you to configure an authentication password for an interface. clear config Clear IS-IS configurations that display under the router isis heading of the show running-config command output. Syntax clear config Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
debug isis Enable debugging for all IS-IS operations. Syntax debug isis To disable debugging of IS-IS, use the no debug isis command. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
• For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(0.2) Introduced on the Z9000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 6.3.1.0 Introduced.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 6.3.1.0 Introduced. debug isis spf-triggers Enable debugging on the events that triggered IS-IS shortest path first (SPF) events for debugging purposes. S4820T Syntax debug isis [vrf vrf-name] spf-triggers To turn off debugging, use the no debug isis [vrf vrf-name] spf-triggers command.
To turn off debugging, use the no debug isis update-packets [interface] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to enable the debugging information on IS-IS. This information contains updates from neighbors tied to the VRF that you specify. This command displays the debugging details of the received LSPs from the neighbors.
route-map mapname Defaults (OPTIONAL) A default route the routing process generates if the route map is satisfied. Not configured. Command Modes Command History • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command Modes Command History Related Commands ROUTER ISIS Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. pre-7.7.1.0 Introduced. router isis — Enter ROUTER mode on the switch. distance Define the administrative distance for learned routes.
Usage Information Version Description 6.3.1.0 Introduced. The administrative distance indicates the trust value of incoming packets. A low administrative distance indicates a high trust rate. A high value indicates a lower trust rate. For example, a weight of 255 is interpreted that the routing information source is not trustworthy and should be ignored. distribute-list in Filter network prefixes received in updates.
Related Commands Version Description 6.3.1.0 Introduced. • distribute-list out — suppresses networks from being advertised in updates. • redistribute — redistributes routes from one routing domain to another routing domain. distribute-list out Suppress network prefixes from being advertised in outbound updates.
Usage Information Related Commands You can assign a name to a routing process so a prefix list IS applied to only the routes derived from the specified routing process. • distribute-list in — filters the networks received in updates. • redistribute — redistributes routes from one routing domain to another routing domain. distribute-list redistributed-override Suppress flapping of routes when the same route is redistributed into IS-IS from multiple routers in the network.
encryption-type (OPTIONAL) Enter 7 to encrypt the password using DES. password Enter an alphanumeric string up to 16 characters long. If you do not specify an encryption type or hmac-md5 keywords, the password is processed as plain text which provides limited security. Defaults No default password. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 6.3.1.0 Introduced on the E-Series. Every graceful restart enabled router’s HELLO PDUs includes a restart TLV. This restart enables (re)starting as well as the existing ISIS peers to detect the GR capability of the routers on the connected network.
Version Description 8.3.1.0 Introduced on the E-Series. graceful-restart restart-wait Enable the graceful restart maximum wait time before a restarting peer comes up. Syntax NOTE: Set the t3 timer to adjacency on the restarting router when implementing this command. graceful-restart restart-wait seconds To return to the default, use the no graceful-restart restart-wait command. Parameters seconds Enter the graceful restart time in seconds. The range is from 5 to 300 seconds.
Parameters interval Enter the keyword interval to set the wait time. The range is from 5 to 120 seconds. The default is 5 seconds. retry-times Enter the keywords retry-times to set the number of times the request interval is extended until a CSNP is received from the helping router. The range is from 1 to 10 attempts. The default is 1. Defaults Refer to Parameters. Command Modes ROUTER ISIS Command History This guide is platform-specific.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Introduced on the E-Series. graceful-restart t3 Configure the overall wait time before graceful restart completes. Syntax graceful-restart t3 {adjacency | manual} seconds To return to the default, use the no graceful-restart t3 command.
Set the t3 timer to adjacency on the restarting router when implementing this command. The restarting router gets the remaining time value from its peer and adjusts its T3 value so only when you have configured graceful-restart t3 adjacency. Related Commands graceful-restart restart-wait — enables the graceful restart maximum wait time before a restarting peer comes up.
hostname dynamic Enables dynamic learning of hostnames from routers in the domain and allows the routers to advertise the hostname in LSPs. Syntax hostname dynamic To disable this command, use the no hostname dynamic command. Defaults Enabled. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. IS-IS normally purges LSPs with an incorrect data link checksum causing the LSP source to regenerate the message. A cycle of purging and regenerating LSPs can occur when a network link continues to deliver accurate LSPs even though there is a link causing data corruption. This process could cause disruption to your system operation.
• router isis — enables the IS-IS routing protocol. ipv6 router isis Enable the IPv6 IS-IS routing protocol and specify an IPv6 IS-IS process. Syntax ipv6 router isis [tag] To disable IS-IS routing, use the no router isis [tag] command. Parameters tag (OPTIONAL) This parameter is a unique name for a routing process. A null tag is assumed if the tag option is not specified. The tag name must be unique for all IP router processes for a given router. Defaults Not configured.
isis circuit-type Configure the adjacency type on interfaces. Syntax isis circuit-type {level-1 | level-1-2 | level-2-only} To return to the default values, use the no isis circuit-type command. Parameters level-1 You can form a Level 1 adjacency if there is at least one common area address between this system and neighbors. You cannot form Level 2 adjacencies on this interface.
Parameters seconds Interval of transmission time between CSNPs on multi-access networks for the designated intermediate system. The range is from 0 to 65535. The default is 10. level-1 (OPTIONAL) Independently configures the interval of time between transmission of CSNPs for Level 1. level-2 (OPTIONAL) Independently configures the interval of time between transmission of CSNPs for Level 2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. Usage Information The holdtime (the product of the hello-multiplier multiplied by the hello-interval) determines how long a neighbor waits for a hello packet before declaring the neighbor is down so routes can be recalculated. Related Commands isis hello-interval — specifies the length of time between hello packets.
To return to the default values, use the no ipv6 isis metric [default-metric] [level-1 | level-2] command. Parameters default-metric Metric assigned to the link and used to calculate the cost from each other router via the links in the network to other destinations. You can configure this metric for Level 1 or Level 2 routing. The range is from 0 to 16777215. The default is 10.
If metric value is configured to more than 63, system throughs the following warning:Warning: for metrics greater than 63, 'metric-style wide' should be configured on level-1-2, or it will be capped at 63. If the metric style is WIDE, the metric values that are greater than 63 are only effective. level-1 (OPTIONAL) Enter the keywords level-1 to configure the shortest path first (SPF) calculation for Level 1 (intra-area) routing. This setting is the default.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. isis password Configure an authentication password for an interface. Syntax isis password [hmac-md5] password [level-1 | level-2] To delete a password, use the no isis password [password] [level-1 | level-2] command. Parameters encryption-type (OPTIONAL) Enter 7 to encrypt the password using DES.
You can assign different passwords for different routing levels by using the keywords level-1 and level-2. The no form of this command disables the password for Level 1 or Level 2 routing, using the respective keywords level-1 or level-2. This password provides limited security as it is processed as plain text. isis priority Set the priority of the designated router you select.
is-type Configure IS-IS operating level for a router. Syntax is-type {level-1 | level-1-2 | level-2-only} To return to the default values, use the no is-type command. Parameters level-1 Allows a router to act as a Level 1 router. level-1-2 Allows a router to act as both a Level 1 and Level 2 router. This setting is the default. level-2-only Allows a router to act as a Level 2 router. Defaults level-1-2 Command Modes ROUTER ISIS Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Added support for LSP Throttling Enhancement. LSP throttling slows down the frequency at which LSPs are generated during network instability.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Added support for LSP Throttling Enhancement. The link MTU and the LSP MTU size must be the same. Because each device can generate a maximum of 255 LSPs, consider carefully whether you use the lspmtu command. lsp-refresh-interval Set the link state PDU (LSP) refresh interval. LSPs must be refreshed before they expire.
The refresh interval must be less than the LSP lifetime specified with the max-lsp-lifetime command. A low value reduces the amount of time that undetected link state database corruption can persist at the cost of increased link utilization. A higher value reduces the link utilization the flooding of refreshed packets causes. Related Commands max-lsp-lifetime — sets the maximum interval that LSPs persist without being refreshed. max-area-addresses Configure manual area addresses.
Parameters seconds The maximum lifetime of LSP in seconds. This value must be greater than the lsp-refresh-interval command. The higher the value the longer the LSPs are kept. The range is from 1 to 65535. The default is 1200. Defaults 1200 seconds Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.8.1.0 Added support for multi-topology ISIS. 6.3.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. If you enter the metric-style wide command, the Dell Networking OS generates and accepts only new-style TLVs. The router uses less memory and other resources rather than generating both old-style and new-style TLVs. The new-style TLVs have wider metric fields than old-style TLVs.
net To configure an IS-IS network entity title (NET) for a routing process, use this mandatory command. If you did not configure a NET, the IS-IS process does not start. Syntax net network-entity-title To remove a net, use the no net network-entity-title command. Parameters network-entity-title Specify the area address and system ID for an IS-IS routing process. The first 1 to 13 bytes identify the area address. The next 6 bytes identify the system ID.
• For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults Not configured. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Defaults Command Modes Command History level-2 (OPTIONAL) Routes are independently redistributed into IS-IS as Level 2 routes. This setting is the default. route-map mapname (OPTIONAL) If you do not enter the route-map argument, all routes are redistributed. If a map-name value is not specified, no routes are imported. • metric metric-value = 0 • metric-type= internal; level-2 • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific.
redistribute bgp Redistribute routing information from a BGP process. Syntax redistribute bgp AS number [level-1| level-1-2 | level-2] [metric metricvalue] [metric-type {external| internal}] [route-map map-name] To return to the default values, use the no redistribute bgp command with the appropriate parameters. Parameters AS number Enter a number that corresponds to the autonomous system number. The range is from 1 to 65355.
Version Description 7.5.1.0 Added support for IPv6 ISIS. 6.3.1.0 Introduced. Usage Information BGP to IS-IS redistribution supports “match” options using route maps. You can set the metric value, level, and metric-type of redistributed routes by the redistribution command. You can “set” more advanced options using route maps.
route-map mapname map-name is an identifier for a configured route map. The route map should filter imported routes from the source routing protocol to the current routing protocol. If you do not specify a map-name, all routes are redistributed. If you specify a keyword, but fail to list route map tags, no routes are imported. Defaults Command Modes Command History Refer to Parameters.
tag (OPTIONAL) This is a unique name for a routing process. A null tag is assumed if the tag option is not specified. The tag name must be unique for all IP router processes for a given router. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
• Command History CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
Example (RouterIsis) The bold section identifies that Multi-Topology IS-IS is enabled in Transition mode. Dell(conf-router_isis)#show config ! router isis clns host ISIS 49.0000.0001.F100.E120.0013.00 log-adjacency-changes net 49.0000.0001.F100.E120.0013.
system-id Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Displays the link-state database for system-id. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added supported for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.
Example Field Description ATT This value represents the Attach bit. This value indicates that the router is a Level 1-2 router and can reach other areas. Level 1-only routers and Level 1-2 routers that have lost connection to other Level 1-2 routers use the Attach bit to find the closest Level 1-2 router. They install a default route to the closest Level 1-2 router. P This value represents the P bit. This bit is always set to zero as Dell Networking does not support area partition repair.
Dell#show isis database detail IS-IS Level-1 Link State Database LSPID LSP Seq Num FTOS.00-00 * 0x00000009 NLPID: 0xCC Area Address: 49.0000.0001 LSP Checksum 0x79D8 LSP Holdtime 941 ATT/P/OL 1/0/0 show isis graceful-restart detail Display detailed IS-IS graceful restart related settings.
====================== Current Mode/State T3 Time left T2 Time left Restart ACK rcv count Restart Req rcv count Suppress Adj rcv count Restart CSNP rcv count Database Sync count : : : : : : : : Normal/RUNNING 0 0 (level-1), 0 0 (level-1), 0 0 (level-1), 0 0 (level-1), 0 0 (level-1), 0 0 (level-1), 0 (level-2) (level-2) (level-2) (level-2) (level-2) (level-2) show isis hostname Display IS-IS host names configured or learned on the switch.
show isis interface Display detailed IS-IS interface status and configuration information. S4820T Syntax Parameters Command Modes Command History show isis [vrf vrf-name] interface [interface] vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display ISIS interface status information corresponding to that VRF.
LSP Interval: 33 TenGigabitEthernet 1/8 is up, line protocol is up MTU 1497, Encapsulation SAP Routing Protocol: IS-IS Circuit Type: Level-1-2 Interface Index 38371358, Local circuit ID 2 Level-1 Metric: 10, Priority: 64, Circuit ID: systest-3.02 Hello Interval: 10, Hello Multiplier: 3, CSNP Interval: 10 Number of active level-1 adjacencies: 1 Level-2 Metric: 10, Priority: 64, Circuit ID: systest-3.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. Use this command to confirm that the neighbor adjacencies are operating correctly. If you suspect that they are not, you can verify the specified area addresses of the routers by using the show isis neighbors command. The following describes the show isis neighbors command shown in the following example.
Parameters Command Modes Command History vrf vrf-name • EXEC • EXEC Privilege (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display ISIS routing information corresponding to that VRF. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display ISIS traffic interface information corresponding to that VRF. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • EXEC • EXEC Privilege • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Example Item Description Level-1/Level-2 LSPs PSNPs (sent/ rcvd) Displays the number of PSNP LPSs sent and received. Level-1/Level-2 DR Elections Displays the number of times designated router elections ran. Level-1/Level-2 SPF Calculations Displays the number of shortest path first calculations. LSP checksum errors received Displays the number of checksum errors LSPs received. LSP authentication failures Displays the number of LSP authentication failures.
Defaults Command Modes Command History initial_wait_interval seconds (OPTIONAL) Enter the initial wait time, in seconds, before running the first SPF calculations. The range is from 0 to 120 seconds. The default is 5 seconds. second_wait_interv al seconds (OPTIONAL) Enter the wait interval, in seconds, between the first and second SPF calculations. The range is from 0 to 120 seconds. The default is 5 seconds. Refer to Parameters.
31 Link Aggregation Control Protocol (LACP) This chapter contains commands for Dell Networks’s implementation of the link aggregation control protocol (LACP) for creating dynamic link aggregation groups (LAGs) — known as “port-channels” in the Dell Networking operating software. The LACP commands in this chapter are supported by Dell Networking OS on the S4820T platform.
Related Commands Version Description 6.2.1.1 Introduced on the E-Series. show lacp — displays the LACP configuration. debug lacp Debug LACP (configuration, events, and so on). S4820T Syntax debug lacp [config | events | pdu [interface-type [in | out]]] To disable LACP debugging, use the no [config | events | pdu [interface-type [in | out]]] command. Parameters config (OPTIONAL) Enter the keyword config to debug the LACP configuration.
Version Description 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. lacp long-timeout Configure a long timeout period (30 seconds) for an LACP session. S4820T Syntax lacp long-timeout To reset the timeout period to a short timeout (1 second), use the no lacp long-timeout command.
lacp port-priority To influence which ports will be put in Standby mode when there is a hardware limitation that prevents all compatible ports from aggregating, configure the port priority. S4820T Syntax lacp port-priority priority-value To return to the default setting, use the no lacp port-priority priority-value command. Parameters priority-value Enter the port-priority value. The higher the value number, the lower the priority. The range is from 1 to 65535. The default is 32768.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
show lacp Display the LACP matrix. S4820T Syntax Parameters Defaults Command Modes Command History show lacp port-channel-number [sys-id | counters] port-channelnumber Enter a port-channel number. The range is from 1 to 128. sys-id (OPTIONAL) Enter the keywords sys-id and the value that identifies a system. counters (OPTIONAL) Enter the keyword counters to display the LACP counters. Without a Port Channel specified, the command clears all Port Channel counters.
Dell# Example (Sys-id) Oper: State BCEGIKNP Key 1 Priority 128 Dell#show lacp 1 sys-id Actor System ID: Priority 32768, Address 0001.e800.a12b Partner System ID: Priority 32768, Address 0001.e801.
32 Layer 2 This chapter describes commands to configure Layer 2 features. This chapter contains the following sections: • MAC Addressing Commands • Virtual LAN (VLAN) Commands • Far-End Failure Detection (FEFD) The VLAN commands are supported on all the S4820T platform. MAC Addressing Commands The following commands are related to configuring, managing, and viewing MAC addresses. clear mac-address-table Clear the MAC address table of all MAC address learned dynamically.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Added support for sticky MAC addresses. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Related Commands Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. mac learning-limit — sets the MAC address learning limits for a selected interface. show mac-address-table aging-time — displays the MAC aging time. mac-address-table static Associate specific MAC or hardware addresses to an interface and VLANs.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Added support for output range parameter for S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. For information about the specific trap sent and the corresponding Syslog, refer to the SNMP Traps chapter. mac-address-table station-move refresh-arp Ensure that address resolution protocol (ARP) refreshes the egress interface when a station move occurs due to a topology change.
Defaults dynamic (OPTIONAL) Enter the keyword dynamic to allow aging of MACs even though a learning limit is configured. station-moveviolation (OPTIONAL) Enter the keywords station-move to allow a station move on learned MAC addresses. • On S-Series, the default behavior is dynamic. NOTE: “Static” means manually entered addresses, which do not age. Command Modes INTERFACE Command History This guide is platform-specific.
When a channel member is added to a port-channel and there is not enough ACL CAM space, the MAC limit functionality on that port-channel is undefined. When this occurs, un-configure the existing configuration first and then reapply the limit with a lower value. Related Commands mac learning-limit mac-address-sticky — Replaces deprecated no-station-move parameter. show mac learning-limit — displays MAC learning-limit configuration.
mac learning-limit mac-address-sticky Maintain the dynamically learned mac addresses as sticky MAC addresses on the selected port. S4820T Syntax mac learning-limit mac-address-sticky To convert the sticky MAC addresses to dynamic MAC addresses, use the no mac learning-limit command. Parameters mac-address-sticky Configures the dynamic MAC addresses as sticky on an interface. Defaults none Command Modes INTERFACE Command History This guide is platform-specific.
shutdown-original Enter the keywords shutdown-original to shut down the original interface and generate a syslog message. Defaults none Command Modes INTERFACE (conf-if-interface-slot/port) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.
Version Description 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series. show cam mac linecard (count) Display the content addressable memory (CAM) size and the portions allocated for MAC addresses and for MAC ACLs.
show cam mac linecard (dynamic or static) Display the CAM size and the portions allocated for MAC addresses and for MAC ACLs. S4820T Syntax Parameters Command Modes Command History show cam mac linecard slot port-set port-pipe [address mac_addr | dynamic | interface interface | static | vlan vlan-id] linecard slot (REQUIRED) Enter the keyword linecard then a slot number to select the linecard for which to gather information.
Example Dell#show cam mac linecard 1 port-set 0 Port - (TableID) assignments: 00(01) 01(01) 02(01) 03(01) 04(01) 05(01) 06(01) 07(01) 08(01) 09(01) 10(01) 11(01) 12(01) 13(01) 14(01) 15(01) 16(01) 17(01) 18(01) 19(01) 20(01) 21(01) 22(01) 23(01) Index Table ID VlanId Mac Address Region Interface 0 1 0 00:01:e8:0d:b7:3b LOCAL_DA 1e000 1 1 0 00:01:e8:0d:b7:3a LOCAL_DA 1e000 101 0 0 00:01:e8:00:04:00 SYSTEM_STATIC 01c05 102 0 0 01:80:00:00:00:00 SYSTEM_STATIC 01c05 103 0 0 01:00:0c:cc:cc:cc SYSTEM_STATIC 01c0
• Command Modes Command History For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. interface interfacetype (OPTIONAL) Instead of entering the keyword interface then the interface type, slot/port information, as above, you can enter the interface type, then just a slot number. vlan vlan-id (OPTIONAL) Enter the keyword vlan then the VLAN ID to display the MAC address assigned to the VLAN. The range is 1 to 4094.
Column Heading Description State Example Lists if the MAC address is in use (Active) or not in use (Inactive). Dell(conf)#do show mac-address-table Codes: *N - VLT Peer Synced MAC VlanId Mac Address Type 2 00:00:00:00:00:01 Dynamic (N) 2 00:00:00:00:00:02 Dynamic (N) 2 00:00:00:00:00:03 Dynamic 2 00:00:00:00:00:04 Dynamic Usage Information Interface Po 128 Po 10 Po 100 Po 10 State Active Active Active Active The following describes the show mac-address-table command shown in the following example.
show mac-address-table aging-time Display the aging times assigned to the MAC addresses on the switch. S4820T Syntax Parameters Command Modes Command History show mac-address-table aging-time [vlan vlan-id] vlan vlan-id • EXEC • EXEC Privilege (OPTIONAL) Enter the keyword vlan then the VLAN ID to display the MAC address assigned to the VLAN. The range is from 1 to 4094. This guide is platform-specific.
vlan vlan-id Command Modes Command History • EXEC • EXEC Privilege • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. (OPTIONAL) Enter the keyword vlan then the VLAN ID to display the MAC address assigned to the VLAN. The range is from 1 to 4094. This guide is platform-specific.
Parameters Command Modes Command History violate-action (OPTIONAL) Enter the keywords violate-action to display the MAC learning limit violation status. detail (OPTIONAL) Enter the keyword detail to display the MAC learning limit in detail. interface interface (OPTIONAL) Enter the keyword interface with the following keywords and slot/port or number information: • EXEC • EXEC Privilege • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
Virtual LAN (VLAN) Commands The following commands configure and monitor virtual LANs (VLANs). VLANs are a virtual interface and use many of the same commands as physical interfaces. You can configure an IP address and Layer 3 protocols on a VLAN called Inter-VLAN routing. FTP, TFTP, ACLs and SNMP are not supported on a VLAN. Occasionally, while sending broadcast traffic over multiple Layer 3 VLANs, the VRRP state of a VLAN interface may continually switch between Master and Backup.
default-vlan disable Disable the default VLAN so that all switchports are placed in the Null VLAN until they are explicitly configured as a member of another VLAN. S4820T Defaults Enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. Usage Information To display information about a named VLAN, enter the show vlan command with the name parameter or the show interfaces description command. Related Commands interface vlan — configures a VLAN.
show vlan Display the current VLAN configurations on the switch. S4820T Syntax Parameters Command Modes Command History show vlan [brief | id vlan-id | name vlan-name] brief (OPTIONAL) Enter the keyword brief to display the following information: • VLAN ID • VLAN name (left blank if none is configured) • Spanning Tree Group ID • MAC address aging time • IP address id vlan-id (OPTIONAL) Enter the keyword id then a number from 1 to 4094. Only information on the VLAN specified is displayed.
Column Heading Description (Column 1 — no heading) asterisk symbol (*) = Default VLAN • G = GVRP VLAN • P = primary VLAN • C = community VLAN • I = isolated VLAN • O = OpenFlow NUM Displays existing VLAN IDs. Status Displays the word Inactive for inactive VLANs and the word Active for active VLANs.
Example (VLAN ID) 5 Active T Po20(Te 13/6) 6 Active U Po3(Te 13/4) 7 Active T Po20(Te 13/6) P 100 Active T Po1(Te 1/1) C 101 I 102 Dell# Inactive T Te 1/3 Inactive T Te 1/4 T Te 13/7 U Te 13/3 T Po20(Te 13/6) T Te 13/7 T Te 13/7 U Te 13/5 T Te 1/2 Dell# show vlan id 40 Codes: Q: U x G - * - Default VLAN, G - GVRP VLANs Untagged, T - Tagged Dot1x untagged, X - Dot1x tagged GVRP tagged, M - Vlan-stack NUM 40 Status Description Q Ports Active M Te 13/47 Dell#show vlan id 41 Codes: Q: U x G - *
Example (OpenFlow instance) * O O O Related Commands NUM 1 3 6 8 12 Status Inactive Inactive Inactive Inactive Inactive Description Q Ports O Te 1/10 vlan-stack compatible — enables the Stackable VLAN feature on the selected VLAN. interface vlan — configures a VLAN. tagged Add a Layer 2 interface to a VLAN as a tagged interface. S4820T Syntax tagged interface To remove a tagged interface from a VLAN, use the no tagged interface command.
Usage Information When you use the no tagged command, the interface is automatically placed in the Default VLAN as an untagged interface unless the interface is a member of another VLAN. If the interface belongs to several VLANs, remove it from all VLANs to change it to an untagged interface. Tagged interfaces can belong to multiple VLANs, while untagged interfaces can only belong to one VLAN at a time. Related Commands interface vlan — configures a VLAN.
Usage Information Version Description pre-6.2.1.1 Introduced on the E-Series. When this command is configured, the VLAN is operationally UP if any of the interfaces specified in the track ip command are operationally UP, and the VLAN is operationally DOWN if none of the tracking interfaces are operationally UP. If the track ip command is not configured, the VLAN's Layer 3 operational state depends on all the members of the VLAN.
Usage Information Version Description 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. Untagged interfaces can only belong to one VLAN. In the Default VLAN, you cannot use the no untagged interface command. To remove an untagged interface from all VLANs, including the Default VLAN, enter INTERFACE mode and use the no switchport command.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. When you enter no fefd for an interface and fefd-global, FEFD is enabled on the interface because the no fefd command is not retained in the configuration file.
• fefd mode — changes FEFD mode on an interface. fefd interval Set an interval between control packets. S4820T Syntax fefd interval seconds To return to the default value, use the no fefd interval command. Parameters seconds Enter a number as the time between FEFD control packets. The range is from 3 to 300 seconds. The default is 15 seconds. Defaults 15 seconds Command Modes INTERFACE Command History This guide is platform-specific.
interface is placed in “error-disabled” state, enter the fefd reset command to reset the interface state. Defaults normal Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. Legacy E-Series command. Related Commands • fefd — enables far-end failure detection. fefd-global interval Configure an interval between FEFD control packets. S4820T Syntax fefd-global interval seconds To return to the default value, use the no fefd-global interval command. Parameters seconds Enter a number as the time between FEFD control packets. The range is from 3 to 300 seconds.
To disable FEFD globally, use the no fefd-global [mode {normal | aggressive}] command. Parameters interval seconds Enter the keyword interval followed by the number of seconds to wait between FEFD control packets. Range is from 3 to 300 seconds. Default is 15 seconds. normal (OPTIONAL) Enter the keywords mode normal to change the link state to “unknown” when a far-end failure the software detects on that interface.
Parameters Command Modes Command History interface (OPTIONAL) Enter the following keywords and slot/port or number information: • EXEC • EXEC Privilege • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. This guide is platform-specific.
Te 5/2 Te 5/3 Te 5/4 Te 5/5 Te 5/6 Te 5/7 Te 5/8 Te 5/9 Te 5/10 Te 5/11 Dell# Related Commands Aggressive Aggressive Aggressive Aggressive Aggressive Aggressive Aggressive Aggressive NA Aggressive 10 10 10 10 10 10 10 10 NA 10 Admin Shutdown Admin Shutdown Admin Shutdown Admin Shutdown Admin Shutdown Admin Shutdown Admin Shutdown Admin Shutdown Locally disabled Err-disabled • fefd — enables far-end failure detection. • fefd disable — disables FEFD on an interface only.
33 Link Layer Discovery Protocol (LLDP) The link layer discovery protocol (LLDP) advertises connectivity and management from the local station to the adjacent stations on an IEEE 802 LAN. This chapter contains the following sections: • LLPD Commands • LLDP-MED Commands LLDP facilitates multi-vendor interoperability by using standard management tools to discover and make available a physical topology for network management.
Command Modes CONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. advertise management-tlv Advertise management TLVs (Type, Length, Value).
Usage Information The command options management-address,system-capabilities, system-description, and system-name can be invoked individually or together, in any sequence. advertise management-tlv (Interface) Advertise management type, length, values (TLVs) to the specified interface.
Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Version Description 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. debug lldp interface To display timer events, neighbor additions or deletions, and other information about incoming and outgoing packets, enable LLDP debugging. S4820T Syntax debug lldp interface {interface | all}{events | packet {brief | detail} {tx | rx | both}} To disable debugging, use the no debug lldp interface {interface | all}{events} {packet {brief | detail} {tx | rx | both}} command.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. disable Enable or disable LLDP. S4820T Syntax disable To enable LLDP, use the no disable command. Defaults Enabled, that is no disable.
hello Configure the rate at which the LLDP control packets are sent to its peer. S4820T Syntax hello seconds To revert to the default, use the no hello seconds command. Parameters seconds Enter the rate, in seconds, at which the control packets are sent to its peer. The rate is from 5 to 180 seconds. The default is 30 seconds. Defaults 30 seconds Command Modes CONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp) Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series.
Version Description 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. protocol lldp (Configuration) Enable the LLDP globally on the switch. S4820T Syntax protocol lldp To disable LLDP globally on the chassis, use the no protocol lldp command. Defaults Enabled. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.1.(0.0) Modified output of detail parameter to display remote management IP addresses. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series.
Number Number Number Number Dell# of of of of Table Table Table Table Inserts Deletes Drops Age Outs : : : : 1621 200 0 400 show running-config lldp Display the current global LLDP configuration. S4820T Syntax show running-config lldp Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
As defined by ANSI/TIA-1057, LLDP-MED provides organizationally specific TLVs (Type Length Value), so that endpoint devices and network connectivity devices can advertise their characteristics and configuration information. The Organizational Unique Identifier (OUI) for the Telecommunications Industry Association (TIA) is 00-12-BB. • LLDP-MED Endpoint Device — any device that is on an IEEE 802 LAN network edge, can communicate using IP, and uses the LLDP-MED framework.
Related Commands Version Description 7.6.1.0 Introduced on the C-Series and E-Series. protocol lldp (Configuration) — enables LLDP globally. debug lldp interface — debugs LLDP. show lldp neighbors — displays the LLDP neighbors. advertise med guest-voice-signaling To advertise a separate limited voice service for a guest user when the guest voice control packets use a separate network policy than the voice data, configure the system.
show lldp neighbors — displays the LLDP neighbors. advertise med location-identification To advertise a location identifier, configure the system. S4820T Syntax advertise med location-identification {coordinate-based value | civic-based value | ecs-elin value} To return to the default, use the no advertise med location-identification {coordinate-based value | civic-based value | ecs-elin value} command.
advertise med power-via-mdi To advertise the Extended Power via MDI TLV, configure the system. S4820T Syntax advertise med power-via-mdi To return to the default, use the no advertise med power-via-mdi command. Defaults unconfigured. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
priority-tagged number Enter the keywords priority-tagged then the Layer 2 priority. The range is from 0 to 7. Defaults unconfigured. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series and E-Series. debug lldp interface — debugs LLDP. show lldp neighbors — displays the LLDP neighbors. advertise med video-signaling To advertise video control packets that use a separate network policy than video data, configure the system.
Related Commands Version Description 7.6.1.0 Introduced on the C-Series and E-Series. debug lldp interface — debugs LLDP. show lldp neighbors — displays the LLDP neighbors. advertise med voice To advertise a dedicated IP telephony handset or other appliances supporting interactive voice services, configure the system.
advertise med voice-signaling To advertise when voice control packets use a separate network policy than voice data, configure the system. S4820T Syntax advertise med voice-signaling {vlan-id layer2_priority DSCP_value} | {priority-tagged number} To return to the default, use the no advertise med voice-signaling {vlan-id layer2_priority DSCP_value} | {priority-tagged number} command. Parameters vlan-id Enter the VLAN ID. The range is from 1 to 4094.
34 Microsoft Network Load Balancing Network Load Balancing (NLB) is a clustering functionality that is implemented by Microsoft on Windows 2000 Server and Windows Server 2003 operating systems. Microsoft NLB clustering allows multiple servers running Microsoft Windows to be represented by one MAC and one IP address to provide transparent failover and load-balancing.
Related Commands clear arp-cache — clears dynamic ARP entries from the ARP table. show arp — displays the ARP table. mac-address-table static (for Multicast MAC Address) For multicast mode of network load balancing (NLB), configure a static multicast MAC address, associate the multicast MAC address with the VLAN used to switch Layer 2 multicast traffic, and add output ports that will receive multicast streams on the VLAN.
Example (Multicast) Version Description 9.3(0.0) Added support for multicast MAC address on the MXL platform. mac-address-table static 01:00:5E:01:00:01 {multicast vlan 2 output—range Te 1/2,Te 1/3} ip vlan-flooding Enable unicast data traffic flooding on VLAN member ports. Syntax ip vlan-flooding To disable, use the no ip vlan-flooding command. Command Modes Command History CONFIGURATION Version 9.3(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL platforms Version Description 9.
35 Multicast Source Discovery Protocol (MSDP) Multicast source discovery protocol (MSDP) connects multiple PIM Sparse-Mode (PIM-SM) domains together. MSDP peers connect using TCP port 639. Peers send keepalives every 60 seconds. A peer connection is reset after 75 seconds if no MSDP packets are received. MSDP connections are parallel with MBGP connections. The Dell Networking operating system supports MSDP commands on the S4820T platform.
clear ip msdp sa-cache Clears the entire source-active cache, the source-active entries of a particular multicast group, rejected, or local source-active entries. S4820T Syntax clear ip msdp sa-cache [group-address | rejected-sa | local] Parameters group-address Enter the group IP address in dotted decimal format (A.B.C.D.).
peer-address Enter the IP address of the MSDP peer. Defaults Without any options, this command clears the entire source-active cache. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.1 Introduced ip msdp cache-rejected-sa Enable an MSDP cache for the rejected source-active entries.
ip msdp default-peer Define a default peer from which to accept all source-active (SA) messages. S4820T Syntax ip msdp default-peer peer address [list name] To remove the default peer, use the no ip msdp default-peer {peer address} list name command. Parameters peer address Enter the peer address in a dotted decimal format (A.B.C.D.) list name Enter the keywords list name and specify a standard access list that contains the RP address that should be treated as the default peer.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.
Usage Information An MSDP mesh group is a mechanism for reducing SA flooding, typically in an intra-domain setting. When some subset of a domain’s MSDP speakers are fully meshed, they can be configured into a mesh-group. If member X of a mesh-group receives a SA message from an MSDP peer that is also a member of the meshgroup, member X accepts the SA message and forwards it to all of its peers that are not part of the meshgroup.
ip msdp peer Configure an MSDP peer. S4820T Syntax ip msdp peer peer address [connect-source] [description] [sa-limit number] To remove the MSDP peer, use the no ip msdp peer peer address [connect-source interface] [description name] [sa-limit number] command. Parameters peer address Enter the peer address in a dotted decimal format (A.B.C.D.).
Usage Information The connect-source option is used to supply a source IP address for the TCP connection. When an interface is specified using the connect-source option, the primary configured address on the interface is used. If the total number of SA messages received from the peer is already larger than the limit when this command is applied, those SA messages continue to be accepted. To enforce the limit in such situation, use the clear ip msdp peer command to reset the peer.
ip msdp sa-filter Permit or deny MSDP source active (SA) messages based on multicast source and/or group from the specified peer. S4820T Syntax ip msdp sa-filter {in | out} peer-address list [access-list name] Remove this configuration using the no ip msdp sa-filter {in | out} peer address list [access-list name] command. Parameters in Enter the keyword in to enable incoming SA filtering. out Enter the keyword out to enable outgoing SA filtering.
Defaults 50000 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.1 Introduced ip multicast-msdp Enable MSDP. S4820T Syntax ip multicast-msdp To exit MSDP, use the no ip multicast-msdp command. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Parameters Defaults Command Modes Command History peer peer address Enter the keyword peer then the peer address in a dotted decimal format (A.B.C.D.). sa-cache Enter the keywords sa-cache to display the Source-Active cache. summary Enter the keyword summary to display an MSDP peer summary. Not configured. • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show ip msdp sa-cache rejected-sa Display the rejected SAs in the SA cache. S4820T Syntax show ip msdp sa-cache rejected-sa Defaults none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example 994 Version Description 9.7(0.0) Introduced on the S6000-ON.
36 Multiple Spanning Tree Protocol (MSTP) Multiple spanning tree protocol (MSTP), as implemented by the Dell Networking operating system, conforms to IEEE 802.1s. This command supports the Dell Networking S4820T platform. debug spanning-tree mstp Enable debugging of the multiple spanning tree protocol and view information on the protocol.
Example Version Description 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series.
Related Commands protocol spanning-tree mstp — enters MULTIPLE SPANNING TREE mode. forward-delay The amount of time the interface waits in the Blocking State and the Learning State before transitioning to the Forwarding State. S4820T Syntax forward-delay seconds To return to the default setting, use the no forward-delay command. Parameters seconds Enter the number of seconds the interface waits in the Blocking State and the Learning State before transiting to the Forwarding State.
hello-time Set the time interval between generation of MSTB bridge protocol data units (BPDUs). S4820T Syntax hello-time seconds To return to the default value, use the no hello-time command. Parameters seconds Enter a number as the time interval between transmission of BPDUs. The range is from 1 to 10. The default is 2 seconds. Defaults 2 seconds Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific.
Parameters max-age Enter a number of seconds the Dell Networking OS waits before refreshing configuration information. The range is from 6 to 40. The default is 20 seconds. Defaults 20 seconds Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced.
Version Description 6.5.1.0 Introduced. Usage Information For two MSTP switches to be within the same MSTP region, the switches must share the same region name (including matching case). Related Commands msti — maps the VLAN(s) to an MST instance. revision — assigns the revision number to the MST configuration. protocol spanning-tree mstp To enable and configure the multiple spanning tree group, enter MULTIPLE SPANNING TREE mode.
Related Commands disable — disables multiple spanning tree. revision The revision number for the multiple spanning tree configuration. S4820T Syntax revision range To return to the default values, use the no revision command. Parameters range Enter the revision number for the MST configuration. The range is from 0 to 65535. The default is 0. Defaults 0 Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific.
show config View the current configuration for the mode. Only non-default values are shown. S4820T Syntax show config Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. Usage Information Enable the multiple spanning tree protocol prior to using this command.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.4.2.1 Support for the optional keyword guard was added on the C-Series, S-Series, and E-Series TeraScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Expanded to display the port error disable state (EDS) loopback BPDU inconsistency causes.
Configured hello time 2, max age 20, forward delay 15, max hops 20 CIST regional root ID Priority 32768, Address 0001.e801.6aa8 CIST external path cost 0 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ---------------------------------------------------------Te 1/1 128.257 128 20000 EDS 0 32768 0001.e801.6aa8 128.257 Interface Name Role PortID Prio Cost Sts Cost Link-type Edge Boundary ---------------------------------------------------------Te 1/1 ErrDis 128.
spanning-tree Enable the multiple spanning tree protocol on the interface. S4820T Syntax spanning-tree To disable the multiple spanning tree protocol on the interface, use the no spanning-tree command. Parameters spanning-tree Enter the keywords spanning-tree to enable the MSTP on the interface. Defaults Enable. Command Modes INTERFACE Command History This guide is platform-specific.
priority priority Defaults • Port Channel interface with one 100 Mb/s Ethernet = 200000 • Port Channel interface with one 1 Gigabit Ethernet = 20000 • Port Channel interface with one 10 Gigabit Ethernet = 2000 • Port Channel with two 1 Gigabit Ethernet = 18000 • Port Channel with two 10 Gigabit Ethernet = 1800 • Port Channel with two 100 Mbps Ethernet = 180000 Enter keyword priority then a value in increments of 16 as the priority. The range is from 0 to 240. The default is 128.
shutdownonviolation (OPTIONAL) Enter the keywords shutdown-on-violation to hardware disable an interface when a BPDU is received and the port is disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced By default, Dell Networking OS implements an optimized flush mechanism for MSTP. This mechanism helps in flushing the MAC addresses only when necessary (and less often) allowing for faster convergence during topology changes.
37 Multicast The multicast commands are supported by Dell Networking operating system (OS) on all S4820T platform. This chapter contains the following sections: • IPv4 Multicast Commands IPv4 Multicast Commands The following section contains the IPv4 multicast commands. clear ip mroute Clear learned multicast routes on the multicast forwarding table. To clear the protocol-independent multicast (PIM) tree information base, use the clear ip pim tib command.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series. E-Series legacy command Related Commands show ip pim tib — shows the PIM tree information base. ip mroute Assign a static mroute.
distance (OPTIONAL) Enter a number as the distance metric assigned to the mroute. The range is from 0 to 255. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(1.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series. This feature allows you to limit the number of multicast entries on the system. This number is the total of all the multicast entries on all line cards in the system. On each line card, the multicast module only installs the maximum number of entries, depending on the configured CAM profile. To store multicast routes, use the IN-L3-McastFib CAM partition.
Usage Information After you enable multicast, you can enable IGMP and PIM on an interface. In INTERFACE mode, enter the ip pim sparse-mode command to enable IGMP and PIM on the interface. Related Commands ip pim sparse-mode — enables IGMP and PIM on an interface. show ip mroute View the multicast routing table. Syntax show ip mroute [vrf vrf-name] [static | group-address [source-address] | count | snooping [vlan vlan-idIntroduced on the S6000-ON.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Added support for keyword vlt to the Z9000, S4810, and S4820T. 8.4.1.1 Support for the keyword snooping and the optional vlan vlan-id, groupaddress, and source-address parameters were added on E-Series ExaScale. 8.3.19.0 Introduced on the S4820T. 8.3.7.
Spanned outgoing interface list: Vlan 20 (S) Usage Information Example The following describes the show ip mroute command shown in the following example. Field Description (S, G) Displays the forwarding entry in the multicast route table. uptime Displays the amount of time the entry has been in the multicast forwarding table. Incoming interface Displays the reverse path forwarding (RPF) information towards the source for (S,G) entries and the RP for (*,G) entries.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810. E-Series legacy command Usage Information Network administrators use static mroutes to control the reach-ability of the multicast sources.
38 Neighbor Discovery Protocol (NDP) The neighbor discovery protocol for IPv6 is defined in RFC 2461 as part of the Stateless Address Autoconfiguration protocol. It replaces the Address Resolution Protocol used with IPv4.
interface interface Command Modes Command History • EXEC • EXEC Privilege To remove all neighbor entries learned on a specific interface, enter the keyword interface then the interface type and slot/port or number information of the interface: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
interface interface hardware_address Enter the keyword interface then the interface type and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number.
interface interface Defaults Command Modes Command History Enter the keyword interface then the interface type and slot/port or number information: • For a port channel interface, enter the keywords port-channel then a number. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port inform • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094.
• Router mode — When a policy with device role as router is applied on an interface, all the RA packets are validated based on the configuration information in the policy. Similarly, you can also apply this mode over any specific VLAN and the validation is performed only for that particular VLAN RA packets. To configure the IPv6 RA guard, use the following Dell Networking OS commands. debug ipv6 nd ra-guard Enable debugging for IPv6 RA guard snooping information.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. • ipv6 nd raguard policy policy-name — Defines the RA guard policy name and enter the RA guard policy configuration mode. • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. hop-limit Enable the verification of the advertised hop count limit. If this command is not configured, the verification process is bypassed.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches.
Related Commands ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. managed-config-flag Set the managed address configuration flag. Syntax managed-config-flag {on | off} To clear the flag, use the no managed-config-flag {on | off} command. Parameters on Enter the keyword on to set the managed-config-flag value as ON. off Enter the keyword off to set the managed-config flag value as OFF.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands.
Parameters on Enter the keyword on to set the other-config-flag value as ON. off Enter the keyword off to set the other-config flag value as OFF. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.
retrans-time Enable the verification of the configured retransmission timer value in the received RA packets. Syntax retrans—timer value To reset the advertised retransmission interval, use the no retrans-timervalue command. Parameters value Enter the advertised retransmission time interval in milliseconds. The range is from 100 to 4,294,967,295 milliseconds. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific.
router-preference maximum Enable the verification of the advertised default router preference (DRP) value. The preference value is lower than or equal to the specified limit. If this command is not configured, the verification process is bypassed. Syntax router-preference maximum {high | low | medium} To reset the default router preference value, use the no router-preference maximum {high | low | medium} command. Parameters high Enter the keyword high to set the DRP value as high.
device-role router hop-limit maximum 251 mtu 1350 other-config-flag on reachable-time 540 retrans-timer 101 router-preference maximum medium trusted-port Dell(conf-ra_guard_policy_list)# Related Commands • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. • ipv6 nd ra-guard policy — Defines the RA guard policy name and enter the RA guard policy list configuration mode. • device-role — Specifies the role of the device attached to the port.
Te 1/1 Dell# Related Commands • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. • ipv6 nd ra-guard policy — Defines the RA guard policy name and enter the RA guard policy list configuration mode. • device-role — Specifies the role of the device attached to the port. • hop-limit — Enables the verification of the advertised hop count limit. • mtu — Sets the maximum transmission unit (MTU) value.
39 Object Tracking Object Tracking supports IPv4 and IPv6, and is available on the Dell Networking, C-Series, E-Series, S-Series, and S4810 platforms. Object tracking allows you to define objects of interest, monitor their state, and report to a client when a change in an object’s state occurs.
Example Version Description 8.4.1.0 Introduced. Dell#debug track all 04:35:04: %RPM0-P:RP2 %OTM-5-STATE: track 6 - Interface TenGigabitEthernet 1/2 line-protocol DOWN 04:35:04: %RPM0-P:RP2 %OTM-5-NOTIF: VRRP notification: resource ID 6 DOWN delay Configure the time delay used before communicating a change in the status of a tracked object to clients. Syntax delay {[up seconds] [down seconds]} To return to the default setting, use the no delay command.
description Enter a description of a tracked object. Syntax description {text} To remove the description, use the no description {text} command. Parameters text Enter a description to identify a tracked object (80 characters maximum). Defaults none Command Modes OBJECT TRACKING (conf_track_object-id) Command History Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced.
track 4 interface TenGigabitEthernet 1/2 ip routing track 5 ip route 192.168.0.0/24 reachability vrf red track resolution ip route isis 20 track resolution ip route ospf 10 Example (Object-id) Dell#show running-config track 300 track 300 ip route 10.0.0.0/8 metric threshold delay down 3 delay up 5 threshold metric up 100 Related Commands • show track – displays information about tracked objects, including configuration, current state, and clients which track the object.
Example Output Description Track object-id Displays the number of the tracked object. Interface type slot/ port, IP route ipaddress, IPv6 route ipv6-address Displays the interface type and slot/port number or address of the IPv4/IPv6 route that is being tracked. object is Up/Down Up/Down state of tracked object; for example, IPv4 interface, reachability or metric threshold of an IP route.
Related Commands • show running-config track – displays configuration information about tracked objects. • track interface ip routing – configures object tracking on the routing status of an IPv4 Layer 3 interface. • track interface line-protocol – configures object tracking on the line-protocol state of a Layer 2 interface. • track ip route metric threshold – configures object tracking on the threshold of an IPv4 route metric.
The tracking process uses a protocol-specific resolution value to convert the actual metric in the routing table to a scaled metric in the range 0 to 255. You can configure the resolution value used to scale route metrics for supported protocols with the track resolution ip route and track resolution ipv6 route commands. Related Commands • track ip route metric threshold – configures object tracking on the threshold of an IPv4 route metric.
track interface line-protocol Configure object tracking on the line-protocol state of a Layer 2 interface. Syntax track object-id interface interface line-protocol To return to the default setting, use the no track object-id command. Parameters object-id Enter the ID number of the tracked object. The range is 1 to 500.
ip-address/ prefixlen Enter an IPv4 address in dotted decimal format. The valid IPv4 prefix lengths are from /0 to /32. vrf vrf-name (Optional) E-Series only: You can configure a VPN routing and forwarding (VRF) instance to specify the virtual routing table to which the tracked route belongs. Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced.
Parameters object-id Enter the ID number of the tracked object. The range is 1 to 500. ip-address/ prefixlen Enter an IPv4 address in dotted decimal format. The valid IPv4 prefix lengths are from /0 to /32. vrf vrf-name (Optional) E-Series only: You can configure a VPN routing and forwarding (VRF) instance to specify the virtual routing table to which the tracked route belongs. Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.
Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. Use this command to configure the protocol-specific resolution value that converts the actual metric of an IPv4 route in the routing table to a scaled metric in the range 0 to 255.
show track ipv6 route Display information about all tracked IPv6 routes, including configuration, current tracked state (UP or DOWN), and the clients which are tracking an object. Syntax Parameters Command Modes Command History Usage Information Example show track ipv6 route [brief] brief • EXEC • EXEC Privilege (OPTIONAL) Display a single line summary of information for tracked IPv6 routes. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.
Usage Command Example (Brief) The following describes the show track ipv6 route brief command shown in the Example below. Ouput Description ResID Number of the tracked object. Resource Type of tracked object. Parameter Detailed description of the tracked object. State Up or Down state of the tracked object. Last Change Time since the last change in the state of the tracked object.
Usage Information Related Commands Version Description 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. Use this command to create an object that tracks the routing state of an IPv6 Layer 3 interface: • The status of the IPv6 interface is UP only if the Layer 2 status of the interface is UP and the interface has a valid IP address.
considers a lower value to have priority over a higher value. The resulting scaled value is compared against the configured threshold values to determine the state of a tracked route as follows: • If the scaled metric for a route entry is less than or equal to the UP threshold, the state of a route is UP. • If the scaled metric for a route is greater than or equal to the DOWN threshold or the route is not entered in the routing table, the state of a route is DOWN.
If the next-hop address in the ARP cache ages out for a route tracked for its reachability, an attempt is made to regenerate the ARP cache entry to if the next-hop address appears before considering the route DOWN. Related Commands • show track ipv6 route – displays information about tracked IPv6 routes, including configuration, current state, and clients which track the route. • track ipv6 route reachability – configures object tracking on the reachability of an IPv4 route.
Related Commands 1050 Object Tracking • threshold metric – configures the metric threshold used to determine the UP and/or DOWN state of a tracked route. • track ipv6 route metric threshold – configures object tracking on the threshold of an IPv6 route metric.
40 Open Shortest Path First (OSPFv2 and OSPFv3) Open Shortest Path First version 2 for IPv4 is supported on platform. OSPF is an Interior Gateway Protocol (IGP), which means that it distributes routing information between routers in a single Autonomous System (AS). OSPF is also a link-state protocol in which all routers contain forwarding tables derived from information about their links to their neighbors.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. area range Summarize routes matching an address/mask at an area border router (ABR).
Version Description pre- 6.1.1.1 Introduced on the E-Series. Usage Information Only the routes within an area are summarized, and that summary is advertised to other areas by the ABR. External routes are not summarized. Related Commands area stub — creates a stub area. router ospf — enters ROUTER OSPF mode to configure an OSPF instance. area stub Configure a stub area, which is an area not connected to other areas.
auto-cost Specify how the OSPF interface cost is calculated based on the reference bandwidth method. S4820T Syntax auto-cost [reference-bandwidth ref-bw] To return to the default bandwidth or to assign cost based on the interface type, use the no auto-cost [reference-bandwidth] command. Parameters ref-bw (OPTIONAL) Specify a reference bandwidth in megabits per second. The range is from 1 to 4294967. The default is 100 megabits per second. Defaults 100 megabits per second.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
neighbor router-id (OPTIONAL) Enter the keyword neighbor then the neighbor’s router-id in dotted decimal format (A.B.C.D.). Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information 1058 Version Description 9.4(0.0) Added support for VRF. Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.
Example Field Description auk: If the ip ospf authentication-key command is configured, this field displays the key used. keyid: If the ip ospf message-digest-key command is configured, this field displays the MD5 key to: Displays the interface to which the packet is intended. dst: Displays the destination IP address. netmask: Displays the destination IP address mask.
metric metric-value (OPTIONAL) Enter the keyword metric then a number to configure a metric value for the route. The range is from 1 to 16777214. metric-type typevalue (OPTIONAL) Enter the keywords metric-type then an OSPF link state type of 1 or 2 for default routes. The values are: route-map mapname • 1 = Type 1 external route • 2 = Type 2 external route (OPTIONAL) Enter the keywords route-map then the name of an established route map. Defaults Disabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. show ip ospf asbr — displays the VLAN configuration. distance Define an administrative distance for particular routes to a specific IP address. S4820T Syntax distance weight [ip-address mask access-list-name] To delete the settings, use the no distance weight [ip-address mask access-list-name] command. Parameters weight Specify an administrative distance. The range is from 1 to 255.
distance ospf Configure an OSPF distance metric for different types of routes. S4820T Syntax distance ospf [external dist3] [inter-area dist2] [intra-area dist1] To delete these settings, use the no distance ospf command. Parameters Defaults external dist3 (OPTIONAL) Enter the keyword external then a number to specify a distance for external type 5 and 7 routes. The range is from 1 to 255. The default is 110.
distribute-list in Apply a filter to incoming routing updates from OSPF to the routing table. S4820T Syntax distribute-list prefix-list-name in [interface] To delete a filter, use the no distribute-list prefix-list-name in [interface] command. Parameters prefix-list-name Enter the name of a configured prefix list. interface (OPTIONAL) Enter one of the following keywords and slot/port or number information: • For Port Channel groups, enter the keywords port-channel then a number.
distribute-list out To restrict certain routes destined for the local routing table after the SPF calculation, apply a filter. S4820T Syntax distribute-list prefix-list-name out [bgp | connected | isis | rip | static] To remove a filter, use the no distribute-list prefix-list-name out [bgp | connected | isis | rip | static] command. Parameters prefix-list-name Enter the name of a configured prefix list. bgp (OPTIONAL) Enter the keyword bgp to specify that BGP routes are distributed.
Usage Information Version Description pre- 6.1.1.1 Introduced on the E-Series. The distribute-list out command applies to routes autonomous system boundary routers (ASBRs) redistributes into OSPF. It can be applied to external type 2 and external type 1 routes, but not to intra-area and inter-area routes. enable inverse-mask By default, Dell Networking Operating System (OS) allows you to input the OSPF network command with a net-mask.
Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. Added support for Multi-Process OSPF. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. The Helper mode is enabled by default on the device. To enable the restart mode also on the device, you must configure the grace period using this command.
graceful-restart mode Enable the graceful restart mode. S4820T Syntax graceful-restart mode [planned-only | unplanned-only] To disable graceful restart mode, use the no graceful-restart mode command. Parameters planned-only (OPTIONAL) Enter the keywords planned-only to indicate graceful restart is supported in a planned restart condition only. unplanned-only (OPTIONAL) Enter the keywords unplanned-only to indicate graceful restart is supported in an unplanned restart condition only.
Defaults By default, OSPF routers are both helper and restart routers during a graceful restart. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T.
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. ip ospf authentication-key Enable authentication and set an authentication key on OSPF traffic on an interface. S4820T Syntax ip ospf authentication-key [encryption-type] key To delete an authentication key, use the no ip ospf authentication-key command. Parameters encryption-type (OPTIONAL) Enter 7 to encrypt the key.
To return to default value, use the no ip ospf cost command. Parameters cost Enter a number as the cost. The range is from 1 to 65535. Defaults The default cost is based on the reference bandwidth. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. Usage Information By default, the dead interval is four times the default hello-interval.
Usage Information The time interval between the hello packets must be the same for routers in a network. Related Commands ip ospf dead-interval — sets the time interval before a router is declared dead. ip ospf message-digest-key Enable OSPF MD5 authentication and send an OSPF message digest key on the interface. S4820T Syntax ip ospf message-digest-key keyid md5 key To delete a key, use the no ip ospf message-digest-key keyid command. Parameters keyid Enter a number as the key ID.
NOTE: The MD5 secret is stored as plain text in the configuration file with service password encryption. Write down or otherwise record the key. You cannot learn the key once it is configured. Use caution when changing the key. ip ospf mtu-ignore Disable OSPF MTU mismatch detection upon receipt of database description (DBD) packets. S4820T Syntax ip ospf mtu-ignore To return to the default, use the no ip ospf mtu-ignore command. Defaults Enabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.
Usage Information Version Description pre- 6.1.1.1 Introduced on the E-Series. Setting a priority of 0 makes the router ineligible for election as a designated router or backup designated router. Use this command for interfaces connected to multi-access networks, not point-to-point networks. ip ospf retransmit-interval Set the retransmission time between lost link state advertisements (LSAs) for adjacencies belonging to the interface.
ip ospf transmit-delay To send a link state update packet on the interface, set the estimated time elapsed. S4820T Syntax ip ospf transmit-delay seconds To return to the default value, use the no ip ospf transmit-delay command. Parameters seconds Enter the number of seconds as the interval between retransmission. The range is from 1 to 3600. The default is 1 second. This value must be greater than the transmission and propagation delays for the interface.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. network area Define which interfaces run OSPF and the OSPF area for those interfaces. S4820T Syntax network ip-address mask area area-id To disable an OSPF area, use the no network ip-address mask area area-id command. Parameters ip-address Specify a primary or secondary address in dotted decimal format.
If you delete all the network area commands for Area 0, the show ip ospf command output does not list Area 0. passive-interface Suppress both receiving and sending routing updates on an interface. S4820T Syntax passive-interface {default | interface} To enable both the receiving and sending routing, use the no passive-interface interface command. To return all OSPF interfaces (current and future) to active, use the no passive-interface default command.
Usage Information Version Description pre- 6.1.1.1 Introduced on the E-Series. Although the passive interface does not send or receive routing updates, the network on that interface is still included in OSPF updates sent using other interfaces. The default keyword sets all interfaces as passive. You can then configure individual interfaces, where adjacencies are desired, using the no passive-interface interface command.
To disable redistribution, use the no redistribute {connected | isis | rip | static} command. Parameters connected Enter the keyword connected to specify that information from active routes on interfaces is redistributed. isis Enter the keyword isis to specify that ISO IS-IS information is redistributed. ospf Enter the keyword ospf to specify that information corresponding to OSPF is redistributes. rip Enter the keyword rip to specify that RIP routing information is redistributed.
Despite removing an OSPF process globally, the OSPF process is not completely removed from the BGP configuration. Related Commands default-information originate — generates a default route into the OSPF routing domain. redistribute bgp Redistribute BGP routing information throughout the OSPF instance.
Version Description 7.4.1.0 Added the keyword default. pre- 6.1.1.1 Introduced on the E-Series. redistribute isis Redistribute IS-IS routing information throughout the OSPF instance.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. router-id To configure a fixed router ID, use this command. S4820T Syntax router-id ip-address To remove the fixed router ID, use the no router-id ip-address command. Parameters ip-address Enter the router ID in the IP address format. Defaults none.
! router ospf 100 router-id 1.1.1.1 Dell(conf-router_ospf)#no router-id Changing router-id will bring down existing OSPF adjacency [y/n]: Dell# router ospf To configure an OSPF instance, enter ROUTER OSPF mode. S4820T Syntax router ospf process-id [vrf {vrf name}] To clear an OSPF instance, use the no router ospf process-id command. Parameters process-id Enter a number for the OSPF instance. The range is from 1 to 65535.
show config Display the non-default values in the current OSPF configuration. S4820T Syntax show config Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Added output for LSA throttling timers. 8.3.7.0 Introduced on the S4810. 7.9.1.0 Added support for VRF. 7.8.1.0 Added support of Multi-Process OSPF. 7.8.1.
show ip ospf interface — displays the OSPF interfaces configured. show ip ospf neighbor — displays the OSPF neighbors configured. show ip ospf asbr Display all autonomous system boundary router (ASBR) routers visible to OSPF. S4820T Syntax show ip ospf [process-id | vrf vrf-name] asbr Parameters Defaults process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
You can determine if an ASBR is in a directly connected area (or not) by the flags. For ASBRs in a directly connected area, E flags are set. In the following example, router 1.1.1.1 is in a directly connected area since the Flag is E/-/-/. For remote ASBRs, the E flag is clear (-/-/-/). Example Dell#show ip ospf 1asbr RouterID 3.3.3.3 1.1.1.1 Dell# Flags -/-/-/ E/-/-/ Cost Nexthop 2 10.0.0.2 0 0.0.0.0 Interface Area Te 1/1 1 0 show ip ospf database Display all LSA information.
Example Field Description Link ID Identifies the router ID. ADV Router Identifies the advertising router’s ID. Age Displays the link state age. Seq# Identifies the link state sequence number. This number allows you to identify old or duplicate link state advertisements. Checksum Displays the Fletcher checksum of an LSA’s complete contents. Link count Displays the number of interfaces for that router. Dell>show ip ospf 1 database OSPF Router with ID (11.1.2.1) (Process ID 1) Router (Area 0.0.
link-state-id adv-router ipaddress Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Specify LSA ID in dotted decimal format. The LSA ID value depends on the LSA type, and it can be one of the following: • the network’s IP address for Type 3 LSAs or Type 5 LSAs • the router’s OSPF router ID for Type 1 LSAs or Type 4 LSAs • the default destination (0.0.0.
Example Field Description Advertising Router Identifies the advertising router’s ID. Checksum Displays the Fletcher checksum of the LSA’s complete contents. Length Displays the length in bytes of the LSA. Network Mask Displays the network mask implemented on the area. TOS Displays the Type of Service (TOS) options. Option 0 is the only option. Metric Displays the LSA metric. Dell#show ip ospf 100 database asbr-summary OSPF Router with ID (1.1.1.10) (Process ID 100) Summary Asbr (Area 0.0.0.
• adv-router ipaddress Command Modes Command History • EXEC • EXEC Privilege the default destination (0.0.0.0) for Type 5 LSAs (OPTIONAL) Enter the keywords adv-router and the ip-address to display only the LSA information about that router. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Example Field Description Length Displays the length in bytes of the LSA. Network Mask Displays the network mask implemented on the area. Metrics Type Displays the external type. TOS Displays the Type of Service (TOS) options. Option 0 is the only option. Metric Displays the LSA metric. Forward Address Identifies the address of the forwarding router. Data traffic is forwarded to this router. If the forwarding address is 0.0.0.0, data traffic is forwarded to the originating router.
show ip ospf database network Display the network (type 2) LSA information. S4820T Syntax Parameters show ip ospf [process-id | vrf vrf-name] database network [link-state-id] [adv-router ip-address] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Example Field Description LS Age Displays the LSA’s age. Options Displays the optional capabilities available on router. The following options can be found in this item: • TOS-capability or No TOS-capability is displayed depending on whether the router can support Type of Service. • DC or No DC is displayed depending on whether the originating router can support OSPF over demand circuits. • E or No E is displayed on whether the originating router can accept AS External LSAs.
show ip ospf database nssa-external Display NSSA-External (type 7) LSA information. S4820T Syntax Parameters show ip ospf [process-id | vrf vrf-name] database nssa-external [linkstate-id] [adv-router ip-address] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
show ip ospf database opaque-area Display the opaque-area (type 10) LSA information. S4820T Syntax show ip ospf [process-id | vrf vrf-name] database opaque-area [link-stateid] [adv-router ip-address] Parameters process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Example Item Description LS Age Displays the LSA’s age. Options Displays the optional capabilities available on router. The following options can be found in this item: • TOS-capability or No TOS-capability is displayed depending on whether the router can support Type of Service. • DC or No DC is displayed depending on whether the originating router can support OSPF over demand circuits. • E or No E is displayed on whether the originating router can accept AS External LSAs.
Parameters process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. link-state-id (OPTIONAL) Specify LSA ID in dotted decimal format.
link-state-id adv-router ipaddress Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Specify LSA ID in dotted decimal format. The LSA ID value depends on the LSA type, and it can be one of the following: • the network’s IP address for Type 3 LSAs or Type 5 LSAs • the router’s OSPF router ID for Type 1 LSAs or Type 4 LSAs • the default destination (0.0.0.
adv-router ipaddress Command Modes Command History • EXEC • EXEC Privilege • the network’s IP address for Type 3 LSAs or Type 5 LSAs • the router’s OSPF router ID for Type 1 LSAs or Type 4 LSAs • the default destination (0.0.0.0) for Type 5 LSAs (OPTIONAL) Enter the keywords adv-router followed by the IP address of an Advertising Router to display only the LSA information about that router. This guide is platform-specific.
Example Item Description LS Seq Number Displays the link state sequence number. This number detects duplicate or old LSAs. Checksum Displays the Fletcher checksum of an LSA’s complete contents. Length Displays the length in bytes of the LSA. Number of Links Displays the number of active links to the type of router (Area Border Router or AS Boundary Router) listed in the previous line. Link connected to: Identifies the type of network to which the router is connected.
Number of TOS metric: 0 TOS 0 Metric: 1 Link connected to: a Stub Network (Link ID) Network/subnet number: 11.1.5.0 --More-Related Commands show ip ospf database — displays OSPF database information. show ip ospf database summary Display the network summary (type 3) LSA routing information. S4820T Syntax show ip ospf [process-id | vrf vrf-name] database summary [link-state-id] [adv-router ip-address] Parameters process-id Enter the OSPF Process ID to show a specific process.
Usage Information Example Version Description 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series. The following describes the show ip ospf process-id database summary command shown in the following example. Item Description LS Age Displays the LSA age. Options Displays the optional capabilities available on router.
Length: 28 Network Mask: /24 TOS: 0 Metric: 1 LS age: 7 Options: (No TOS-capability, No DC, E) LS type: Summary Network Link State ID: 192.68.33.0 Advertising Router: 1.1.1.10 LS Seq Number: 0x80000016 Checksum: 0x1241 Length: 28 Network Mask: /26 TOS: 0 Metric: 1 Dell# Related Commands show ip ospf database — displays OSPF database information. show ip ospf interface Display the OSPF interfaces configured. If OSPF is not enabled on the switch, no output is generated.
Usage Information Example Version Description 9.4.(0.0) Added support for VRF. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series.
Internet Address 192.168.0.1/24, Area 0.0.0.1 Process ID 1, Router ID 192.168.253.2, Network Type BROADCAST, Cost: 1 Transmit Delay is 1 sec, State DROTHER, Priority 1 Designated Router (ID) 192.168.253.5, Interface address 192.168.0.4 Backup Designated Router (ID) 192.168.253.3, Interface address 192.168.0.2 Timer intervals configured, Hello 10, Dead 40, Wait 40, Retransmit 5 Hello due in 00:00:08 Neighbor Count is 3, Adjacent neighbor count is 2 Adjacent with neighbor 192.168.253.
Example Item Description Neighbor ID Displays the neighbor router ID. Pri Displays the priority assigned neighbor. State Displays the OSPF state of the neighbor. Dead Time Displays the expected time until FTOS declares the neighbor dead. Address Displays the IP address of the neighbor. Interface Displays the interface type slot/port information. Area Displays the neighbor’s area (process ID). Dell#show ip ospf 34 neighbor Neighbor ID 20.20.20.7 192.10.10.2 20.20.20.
Usage Information Version Description 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series and E-Series. This command is useful in isolating routing problems between the OSPF and the RTM. For example, if a route is missing from the RTM/FIB but is visible from the display output of this command, the problem is with downloading the route to the RTM.
neighbor router-id Defaults Command Modes Command History • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. (OPTIONAL) Enter the keyword neighbor then the neighbor’s router-id in dotted decimal format (A.B.C.D.).
Row Heading Description TxQ-Len The transmission queue length. RxQ-Len The reception queue length. Tx-Mark The highest number mark in the transmission queue. Rx-Mark The highest number mark in the reception queue. Hello-Q The queue, for transmission or reception, for the hello packets. LSR-Q The queue, for transmission or reception, for the link state request packets.
Hello-Q LSR-Q Other-Q 0 0 0 0 0 0 0 0 0 2 0 0 Error packets (Only for RX) Intf-Down Wrong-Len Auth-Err Version No-Buffer Q-OverFlow 0 0 0 0 0 0 Non-Dr Invld-Nbr MD5-Err AreaMis Seq-No Unkown-Pkt 0 0 0 0 0 0 Self-Org 0 Nbr-State 0 Chksum 0 Conf-Issues 0 Socket 0 Error packets (Only for TX) Socket Errors Dell# Usage Information Example (Statistics) 0 The show ip ospf process-id statistics command displays the error packet count received on each interface as: • The hello-timer remaining value for
Parameters Defaults process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to view LSAs corresponding to a specific VRF that are currently in queue waiting for timers to expire. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series.
• hold-interval: 5000 msec • max-interval: 5000 msec Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 9.0.2.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810. OSPFv3 Commands Open shortest path first version 3 (OSPFv3) for IPv6 is supported on the S4820T platform. The fundamental mechanisms of OSPF (flooding, DR election, area support, SPF calculations, and so on) remain unchanged. However, OSPFv3 runs on a per-link basis instead of on a per-IP-subnet basis. Most changes were necessary to handle the increased address size of IPv6.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 8.4.2.0 Introduced on the E-Series TeraScale.
key-encryptionalgorithm (OPTIONAL) Specifies if the key is encrypted. Valid values: 0 (key is not encrypted) or 7 (key is encrypted). key Text string used in encryption. The required lengths of a non-encrypted or encrypted key are: 3DES - 48 or 96 hex digits; DES - 16 or 32 hex digits; AES-CBC -32 or 64 hex digits for AES-128 and 48 or 96 hex digits for AES-192. authenticationalgorithm Specifies the authentication algorithm to use for encryption. Valid values are MD5 or SHA1.
When you configure encryption for an OSPFv3 area with the area encryption command, you enable both IPsec encryption and authentication. However, when you enable authentication on an area with the area authentication command, you do not enable encryption at the same time. If you have enabled IPsec authentication in an OSPFv3 area with the area authentication command, you cannot use the area encryption command in the area at the same time.
debug ipv6 ospf bfd Display debug information and interface types for bidirectional forwarding detection (BFD) on OSPF IPv6 packets. S4820T Syntax Parameters [no] debug ipv6 ospf bfd [interface] interface (OPTIONAL) Enter one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
fe80:0000:0000:0000:0201:e8ff:fe8b:7720 Interface Te 1/2 IfIndex 34145282 00:59:27 : OSPFv3INFO: BFD parameters interval 100 min_rx 100 mult 3 role active 00:59:27 : OSPFv3INFO: BFD parameters interval 100 min_rx 100 mult 3 role active 00:59:27 : OSPFv3INFO: Completed Enabling BFD for NBRIP fe80:0000:0000:0000:0201:e8ff:fe8b:7720 Aug 25 11:19:59: %STKUNIT0-M:CP %BFDMGR-1-BFD_STATE_CHANGE: Changed session state to Init for neighbor fe80::201:e8ff:fe8b:7720 on interface Te 1/2 (diag: NBR_DN) Aug 25 11:20:00:
ID:223.255.255.255, Area ID:0, Chksum:a177, Inst:0, from Vl 100 05:20:25 : OSPFv3: Sending, Ver:3, Type:4(LS Update), Len:580, Router ID:223.255.255.254, Area ID:0, Inst:0, on Vl 1000 07:21:40 : OSPFv3: Received, Ver:3, Type:1(Hello), Len:40, Router ID: 223.255.255.254, Area ID:0, Chksum:af8f, Inst:0, from Te 1/6 Dell# Command Fields Lines Beginning With or Including Description OSPFv3... Debugging is on for all OSPFv3 packets and all interfaces. 05:21:01 Displays the time stamp.
• route-map mapname 2 = Type 2 external route (OPTIONAL) Enter the keywords route-map then the name of an established route map. Defaults Disabled. Command Modes ROUTER OSPFv3 Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.1.(0.
To enable OSPFv3 graceful restart, enter the ipv6 router ospf command to enter OSPFv3 configuration mode and then configure a grace period using the graceful-restart grace-period command. The grace period is the length of time that OSPFv3 neighbors continue to advertise the restarting router as though it is fully adjacent. When graceful restart is enabled (restarting role), an OSPFv3 restarting expects its OSPFv3 neighbors to help when it restarts by not advertising the broken link.
ipv6 ospf area Enable IPv6 OSPF on an interface. S4820T Syntax ipv6 ospf process id areaarea id To disable OSPFv6 routing for an interface, use the no ipv6 ospf process-id area area-id command. Parameters process-id Enter the process identification number. area area-id Specify the OSPF area. The range is from 0 to 65535. Defaults none Command Modes INTERFACE Command History Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.4.1.
Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.1.(0.0) Introduced on S4810 and Z9000. 8.4.2.0 Introduced on the E-Series. 8.3.19.0 Introduced on the S4820T.
multiplier value Enter the keyword multiplier to specify the number of packets that must be missed in order to declare a session down. The range is from 3 to 50. The default is 3. role [active | passive] Enter the role that the local system assumes: • Active — The active system initiates the BFD session. Both systems can be active for the same session. • Passive — The passive system does not initiate a session. It only responds to a request for session initialization from the active system.
Usage Information Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 7.8.1.0 Added support for C-Series. 7.4.1.0 Introduced on the E-Series. 8.3.19.0 Introduced on the S4820T.
ipv6 ospf encryption Configure an IPsec encryption policy for OSPFv3 packets on an IPv6 interface. S4820T Syntax ipv6 ospf encryption {null | ipsec spi number esp encryption-algorithm [key-encryption-type] key athentication-algorithm [key-encryption-type] key}} Parameters null Causes an encryption policy configured for the area to not be inherited on the interface. ipsec spi number Security Policy index (SPI) value that identifies an IPsec security policy. The range is from 256 to 4294967295.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.4.2.0 Introduced on the E-Series TeraScale. 8.3.19.0 Introduced on the S4820T. Before you enable IPsec encryption on an OSPFv3 interface, first enable IPv6 unicast routing globally, configure an IPv6 address and enable OSPFv3 on the interface, and assign the interface to an area.
When configured in a helper-reject role, an OSPFv3 router ignores the Grace LSAs that it receives from a restarting OSPFv3 neighbor. The graceful-restart role command is not supported in OSPFv3. When you enable the helper-reject role on an interface, you reconfigure an OSPFv3 router to function in a “restarting-only” role. ipv6 ospf hello-interval Specify the time interval between the hello packets sent on the interface.
Defaults 1 Command Modes INTERFACE Command History Usage Information Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for the C-Series. 7.4.1.0 Introduced on the E-Series. Setting a priority of 0 makes the router ineligible for election as a Designated Router or Backup Designated Router. Use this command for interfaces connected to multi-access networks, not point-to-point networks.
maximum-paths Enable the software to forward packets over multiple paths. S4820T Syntax maximum-paths number To disable packet forwarding over multiple paths, use the no maximum-paths command. Parameters number Defaults 8 Command Modes ROUTER OSPF Command History Specify the number of paths. The range is from 1 to 64. The default is 8 paths. Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
ROUTER OSPFv3 for OSPFv3 Command History Usage Information Version Description 9.2(1.0) Introduced on the Z9500. 9.1.(0.0) Introduced support for OSPFv3 on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for the C-Series. 7.4.1.0 Introduced on the E-Series. By default, no interfaces are passive. Routing updates are sent to all interfaces on which the routing protocol is enabled.
metric-type typevalue (OPTIONAL) Enter the keywords metric-type then the OSPFv3 link state type of 1 or 2 for default routes. The values are: • 1 for a type 1 external route • 2 for a type 2 external route The default is 2. route-map mapname (OPTIONAL) Enter the keywords route-map then the name of an established route map. If the route map is not configured, the default is deny (to drop all routes). tag tag-value (OPTIONAL) Enter the keyword tag to set the tag for routes redistributed into OSPFv3.
Parameters ip-address Enter the router ID in the dotted decimal format. Defaults The router ID is selected automatically from the set of IPv4 addresses configured on a router. Command Modes ROUTER OSPF for OSPFv2 ROUTER OSPFv3 for OSPFv3 Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.4.2.0 Introduced on the E-Series TeraScale. 8.3.19.0 Introduced on the S4820T. The show crypto ipsec policy command output displays the AH and ESP parameters configured in IPsec security policies, including the SPI number, keys, and algorithms used. When configured in a helper-reject role, an OSPFv3 router ignores the Grace LSAs that it receives from a restarting OSPFv3 neighbor.
Inbound ESP Auth Key The ESP authentication key for inbound and outbound links. Outbound ESP Auth Key Inbound ESP Cipher Key The ESP encryption key for inbound and outbound links. Outbound ESP Cipher Key Transform set The set of security protocols and algorithms used in the policy. Inbound AH SPI The authentication header (AH) security policy index (SPI) for inbound and outbound links. Outbound AH SPI Inbound AH Key The AH key for inbound and outbound links.
Usage Information The show crypto ipsec sa ipv6 command output displays security associations set up for OSPFv3 links in IPsec authentication and encryption policies on the router. Related Commands show crypto ipsec policy – displays the configuration of IPsec authentication and encryption policies.
IPSecv6 policy name Name of the IPsec security policy applied to the interface. inbound/outbound ah Authentication policy applied to inbound or outbound traffic. inbound/outbound esp Encryption policy applied to inbound or outbound traffic. spi Security policy index number used to identify the policy. transform Security algorithm that is used to provide authentication, integrity, and confidentiality. in use settings Transform that the SA uses (only transport mode is supported).
Version Description 8.4.2.2 Added support for the display of graceful restart parameters and Type-11 Grace LSAs on E-Series TeraScale routers. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for C-Series. Usage Information The show crypto ipsec sa ipv6 command output displays security associations set up for OSPFv3 links in IPsec authentication and encryption policies on the router.
AS Bdr Rtr Count 1 LSA count 8 Rtr LSA Count 1 Net LSA Count 0 Inter Area Pfx LSA Count 5 Inter Area Rtr LSA Count 0 Group Mem LSA Count 0 Type-7 LSA count 0 Intra Area Pfx LSA Count 2 Intra Area TE LSA Count 2 E1200-T2C2#sh ipv6 ospf neighbor Neighbor ID Interface 63.114.8.36 Pri 1 State FULL/DR Dead Time Interface ID 00:00:37 4 Te 1/4 show ipv6 ospf interface View OSPFv3 interface information.
Usage Information Version Description 7.4.1.0 Introduced on the E-Series. If you enable BFD at the global level, show ipv6 ospf interface shows the BFD provisioning. If you enable BFD at the interface level, show ipv6 ospf interface shows the BFD interval timers. Example Dell#show ipv6 ospf 3 interface tengigabitethernet 1/2 TenGigabitEthernet 1/2 is up, line protocol is up Link Local Address fe80::201:e8ff:fe17:5bbd, Interface ID 67420217 Area 0, Process ID 1, Instance ID 0, Router ID 11.1.1.
Command History Example Version Description 9.7(0.0) Added support for VRF. 9.2(1.0) Introduced on the Z9500. 9.1.(0.0) Introduced support for OSPFv3 on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for the C-Series. 7.4.1.0 Introduced on the E-Series. Dell#show ipv6 ospf 3 neighbor gi 1/2 Neighbor ID 63.114.8.
! ipv6 router ospf 1 timers spf 2 5 Dell(conf-ipv6-router_ospf)# Dell(conf-ipv6-router_ospf)#end Dell# 1150 Open Shortest Path First (OSPFv2 and OSPFv3)
41 Policy-based Routing (PBR) Policy-based routing (PBR) allows you to apply routing policies to specific interfaces. To enable PBR, create a redirect list and apply it to the interface. After the redirect list is applied to the interface, all traffic passing through the interface is subject to the rules defined in the redirect list. PBR is supported by the Dell Networking Operating System (OS).
ip redirect-group Apply a redirect list (policy-based routing) on an interface. You can apply multiple redirect lists to an interface by entering this command multiple times. S4820T Syntax ip redirect-group redirect-list-name To remove a redirect list from an interface, use the no ip redirect-group name command. Parameters redirect-list-name Enter the name of a configured redirect list. Defaults none Command Modes INTERFACE (conf-if-vl-) Command History Usage Information Version Description 9.
Parameters redirect-list-name Defaults None Command Modes CONFIGURATION Command History Enter the name of a redirect list. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.2.0 Introduced on the E-Series Tera Scale. 7.7.1.0 Introduced on the E-Series ExaScale. permit Configure a permit rule.
operator Defaults none Command Modes REDIRECT-LIST Command History • ack = acknowledgement • fin = finish (no more data from the user) • psh = push function • rst = reset the connection • syn = synchronize sequence number • urg = urgent field (OPTIONAL) For TCP and UDP parameters only.
ip-address Enter the IP address of the forwarding router. slot/port Enter the keyword slot / port followed by the slot/port information. tunnel Enter the keyword tunnel to configure the tunnel setting. tunnel-id Enter the keyword tunnel-id to redirect the traffic. track Enter the keyword track to enable the tracking. track Enter the keyword track to track object-id. ip-protocol-number Enter a number from 0 to 255 for the protocol identified in the IP protocol header.
Version Description 9.7(0.0) Added support for the track-id on the S4810, S4820T, S6000, and Z9000. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.2.0 Introduced on the E-Series Tera Scale. 7.7.1.0 Introduced on the E-Series ExaScale. seq Configure a filter with an assigned sequence number for the redirect list.
host ip-address Enter the keyword host then the IP address to specify a host IP address. destination Enter the IP address of the network or host to which the packets are sent.
show cam pbr Display the PBR CAM content. S4820T Syntax show cam pbr {[interface interface] | stack—unit slot-number port-set number]} [summ Parameters interface interface Enter the keyword interface then the name of the interface. stack–unit number Enter the keyword stack-unit then the slot number. port-set number Enter the keywords port-set then the port-pipe number. summary Enter the keyword summary to view only the total number of CAM entries.
Parameters Command Modes Command History Example redirect-list-name • EXEC • EXEC Privilege Enter the name of a configured Redirect list. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. Dell#show ip redirect-list explicit_tunnel IP redirect-list explicit_tunnel: Defined as: seq 5 redirect tunnel 1 track 1 tcp 155.55.2.0/24 222.22.2.
42 PIM-Sparse Mode (PIM-SM) The protocol-independent multicast (PIM) commands are supported by the Dell Networking operating software on the platform. IPv4 PIM-Sparse Mode Commands The following describes the IPv4 PIM-sparse mode (PIM-SM) commands. clear ip pim rp-mapping The bootstrap router (BSR) feature uses this command to remove all or particular rendezvous point (RP) advertisement.
Usage Information This command re-applies the RP mapping logic for all the groups learnt by the node. Any stale information corresponding to the existing mapping configuration is updated. As a result, the existing BSR cache and the *,G's are deleted only if these entries are stale. clear ip pim tib Clear PIM tree information from the PIM database.
debug ip pim View IP PIM debugging messages. S4820T Syntax debug ip pim [vrf vrf-name] [bsr | events | group | packet [in | out] | register | state | timer [assert | hello | joinprune | register]] To disable PIM debugging, use the no debug ip pim [vrf vrf-name] command or use the undebug allto disable all debugging command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to view IP PIM debugging messages corresponding to that VRF.
Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. ip pim bsr-border Define the border of PIM domain by filtering inbound and outbound PIM-BSR messages per interface. Syntax ip pim bsr-border To return to the default value, use the no ip pim bsr-border command.
Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure the PIM router on a VRF. interface Enter the following keywords and slot/port or number information: • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Defaults 1 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series for the port-channels and the S-Series. 7.7.1.0 Introduced on the E-Series. Example Dell(conf)# ip access-list extended iptv-channels Dell(config-ext-nacl)# permit ip 10.1.2.3/24 225.1.1.
ip pim neighbor-filter To prevent a router from participating in protocol independent multicast (PIM), configure this feature. S4820T Syntax ip pim [vrf vrf-name] neighbor-filter {access-list} To remove the restriction, use the no ip pim [vrf vrf-name] neighbor-filter {accesslist} command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to prevent that VRF from participating in PIM. NOTE: Applies to specific VRF if input is provided, else applies to default VRF.
Parameters seconds Enter a number as the number of seconds between router query messages. The range is from 0 to 65535. The default is 30 seconds. Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON.
Usage Information Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. 7.6.1.0 Introduced The access name is an extended IP access list that denies PIM register packets to RP at the source DR based on the multicast and group addresses. Do not enter this command before creating the access-list.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. pre- 6.1.1.1 Introduced on the E-Series. First-hop routers use this address by to send register packets on behalf of source multicast hosts. The RP addresses are stored in the order in which they are entered.
Usage Information Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. pre- 6.1.1.1 Introduced on the E-Series. Priority is stored at BSR router when receiving a Candidate-RP-Advertisement.
ip pim sparse-mode sg-expiry-timer Enable expiry timers globally for all sources. S4820T Syntax ip pim [vrf vrf-name] sparse-mode sg-expiry-timer seconds To disable configured timers and return to default mode, use the no ip pim [vrf vrf-name] sparse-mode sg-expiry-timer command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to enable expiry timer for all sources on that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF.
ip pim ssm-range Specify the SSM group range using an access list. Syntax Parameters ip pim [vrf vrf-name] ssm-range {access_list_name} vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to specify the SSM group range for that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. access_list_name Enter the name of the access list.
When you remove the SSM ACL, PIM SSM is supported for the default SSM range only. ip pim spt-threshold To switch to the shortest path tree when the traffic reaches the specified threshold value, configure the PIM router. S4820T Syntax ip pim [vrf vrf-name] spt-threshold [infinity] To return to the default value, use the no ip pim [vrf vrf-name] spt-threshold [infinity] command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced on the E-Series ExaScale.
Example Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. Dell#show ip pim bsr-router PIMv2 Bootstrap information This system is the Bootstrap Router (v2) BSR address: 7.7.7.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. The following describes the show ip pim interface command shown in the following example. Field Description Address Lists the IP addresses of the interfaces participating in PIM. Interface List the interface type, with either slot/port information or ID (VLAN or Port Channel), of the interfaces participating in PIM.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
show ip pim rp View all multicast groups-to-RP mappings. S4820T Syntax Parameters Command Modes Command History show ip pim [vrf vrf-name] rp [mapping | group-address] vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. mapping (OPTIONAL) Enter the keyword mapping to display the multicast groups-to-RP mapping and information on how RP is learnt.
Example (Address) Dell#show ip pim rp 229.1.2.1 Group RP 229.1.2.1 165.87.20.4 show ip pim snooping interface Display information on VLAN interfaces with PIM-SM snooping enabled. Syntax show ip pim snooping interface [vlan vlan-id] Parameters Command Modes Command History vlan vlan-id • EXEC • EXEC Privilege (OPTIONAL) Enter a VLAN ID to display information about a specified VLAN configured for PIM-SM snooping. The valid VLAN IDs range is from 1 to 4094. This guide is platform-specific.
show ip pim snooping neighbor Display information on PIM neighbors learned through PIM-SM snooping. Syntax Parameters Command Modes Command History show ip pim snooping neighbor [vlan vlan-id] vlan vlan-id • EXEC • EXEC Privilege (OPTIONAL) Enter a VLAN ID to display information about PIM neighbors that PIM-SM snooping discovered on a specified VLAN. The valid VLAN IDs range is from 1 to 4094. This guide is platform-specific.
Neighbor Interface Uptime/Expires Ver Address 165.87.32.2 Vl 2 [Te 1/13 ] 00:04:03/00:01:42 v2 165.87.32.10 Vl 2 [Te 1/11 ] 00:00:46/00:01:29 v2 165.87.32.12 Vl 2 [Te 2/20 ] 00:00:51/00:01:24 v2 DR Prio 1 0 0 show ip pim snooping tib Display information from the tree information base (TIB) PIM-SM snooping discovered about multicast group members and states.
Field Example Description • R = the forwarding entry is pointing toward the RP • F = Dell Networking OS is registering this entry for a multicast source • T = packets were received via Shortest Tree Path • J = first packet from the last hop router is received and the entry is ready to switch to SPT • K=acknowledge pending state Incoming interface Displays the reverse path forwarding (RPF) interface towards the RP/ source.
Command Modes Command History Exmaple • EXEC • EXEC Privilege Version Description 9.7(0.0) Introduced on the S6000-ON. Added support for VRF on S6000, S4810, S4820T, Z9000, Z9500, and S6000–ON. 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.
Example Version Description 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.4.1.1 Support for the display of PIM-SM snooping status was added on E-Series ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series.
NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. Command Modes Command History group-address (OPTIONAL) Enter the group address in dotted decimal format (A.B.C.D). source-address (OPTIONAL) Enter the source address in dotted decimal format (A.B.C.D). • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Field Description • Example K = acknowledge pending state Incoming interface Displays the reverse path forwarding (RPF) interface towards the RP/ source. RPF neighbor Displays the next hop from this interface towards the RP/source.
Example 1188 Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Introduced on the E-Series ExaScale.
43 Port Monitoring The port monitoring feature allows you to monitor network traffic by forwarding a copy of each incoming or outgoing packet from one port to another port. Important Points to Remember • Port monitoring is supported on physical ports and logical interfaces, such as port channels and virtual local area networks (VLANs). • The monitoring (destination, “MG”) and monitored (source, “MD”) ports must be on the same switch.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-7.7.1.0 Introduced on the E-Series. monitor session — enables a monitoring session. monitor session Create a session for monitoring traffic with port monitoring.
Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Added the drop parameter. 9.7(0.0) Introduced on the S6000-ON. Introduced the set ip dscp and set ip ttl parameters. 9.5(0.1) Introduced on the Z9500. 9.4(0.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.8(0.0) Introduced on the S4810, S4820T, S5000, S6000, S6000-ON, Z9500. monitor session — enables a monitoring session. show monitor session — displays the monitor session.
show monitor session Display information about monitoring sessions. Syntax show monitor session {session-ID} To display monitoring information for all sessions, use the show monitor session command. Parameters Defaults Command Modes Command History session-ID (OPTIONAL) Enter a session identification number. The range is from 0 to 65535. none • EXEC • EXEC Privilege This guide is platform-specific.
show running-config monitor session Display the running configuration of all monitor sessions or a specific session. Syntax show running-config monitor session {session-ID} To display the running configuration for all monitor sessions, use the show running-config monitor session command. Parameters Defaults session-ID (OPTIONAL) Enter a session identification number. The range from 0 to 65535. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
source (port monitoring) Configure a port monitor source. Syntax source {interface | range | any} destination interface direction {rx | tx | both} To disable a monitor source, use the no source interface destination interface direction {rx | tx | both} command. Parameters source interface Enter one of the following keywords and slot/port information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example 1196 Version Description 9.8(0.0) Added the any parameter. 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.4.0.0 Added support for Source and destination. 9.0.2.0 Introduced on the S6000. 8.3.19.
44 Private VLAN (PVLAN) The private VLAN (PVLAN) feature of the Dell Networking operating software is supported on the S4820T platforms. Private VLANs extend the Dell Networking OS security suite by providing Layer 2 isolation between ports within the same private VLAN. A private VLAN partitions a traditional VLAN into subdomains identified by a primary and secondary VLAN pair. The Dell Networking OS private VLAN implementation is based on RFC 3069. For more information, refer to the following commands.
– A trunk port in a PVLAN is always tagged. – A trunk port in Tagged mode carries primary or secondary VLAN traffic. The tag on the packet helps identify the VLAN to which the packet belongs. – A trunk port can also belong to a regular VLAN (non-private VLAN). ip local-proxy-arp Enable/disable Layer 3 communication between secondary VLANs in a private VLAN.
private-vlan mode Set PVLAN mode of the selected VLAN to community, isolated, or primary. S4820T Syntax [no] private-vlan mode {community | isolated | primary} To remove the PVLAN configuration, use the no private-vlan mode {community | isolated | primary} command syntax. Parameters community Enter the keyword community to set the VLAN as a community VLAN. isolated Enter the keyword isolated to configure the VLAN as an isolated VLAN.
private-vlan mapping secondary-vlan Map secondary VLANs to the selected primary VLAN. S4820T Syntax [no] private-vlan mapping secondary-vlan vlan-list To remove specific secondary VLANs from the configuration, use the no private-vlan mapping secondary-vlan vlan-list command syntax. Parameters vlan-list Enter the list of secondary VLANs to associate with the selected primary VLAN. The list can be in comma-delimited or hyphenated-range format, following the convention for the range input.
switchport mode private-vlan Set PVLAN mode of the selected port. S4820T Syntax [no] switchport mode private-vlan {host | promiscuous | trunk} To remove PVLAN mode from the selected port, use the no switchport mode private-vlan command. Parameters host Enter the keyword host to configure the selected port or port channel as an isolated interface in a PVLAN. promiscuous Enter the keyword promiscuous to configure the selected port or port channel as an promiscuous interface.
Related Commands private-vlan mode — sets the mode of the selected VLAN to community, isolated, or primary. private-vlan mapping secondary-vlan — sets the mode of the selected VLAN to primary and then associates the secondary VLANs to it.
45 Per-VLAN Spanning Tree Plus (PVST+) The Dell Networking operating software implementation of per-VLAN spanning tree plus (PVST+) is based on the IEEE 802.1w standard spanning tree protocol. Dell Networking OS supports PVST+ on the S4820T platform. NOTE: For easier command line entry, the plus (+) sign is not used at the command line. description Enter a description of the PVST+. S4820T Syntax description {description} To remove the description, use the no description {description} command.
disable Disable PVST+ globally. S4820T Syntax disable To enable PVST+, use the no disable command. Defaults Disabled. Command Modes CONFIGURATION (conf-pvst) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced. Dell(conf-pvst)#do show spanning-tree pvst vlan 5 brief VLAN 5 Executing IEEE compatible Spanning Tree Protocol Root ID Priority 32773, Address 0001.e832.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 8.3.1.0 Introduced.
• guard Defaults Command Modes Command History For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. (OPTIONAL) Enter the keyword guard to display the type of guard enabled on a PVST interface and the current port state. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Configured hello time 2, max age 20, forward delay 15 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ---------------------------------------------------------Te 1/0 128.130 128 20000 FWD 20000 4096 0001.e801.6aa8 128.426 Te 1/1 128.131 128 20000 BLK 20000 4096 0001.e801.6aa8 128.427 Te 1/16 128.146 128 20000 FWD 20000 16384 0001.e805.e306 128.146 Te 1/17 128.147 128 20000 FWD 20000 16384 0001.e805.e306 128.
Edge port:no (default) port guard :none (default) Link type: point-to-point (auto) bpdu filter:disable (default) Bpdu guard :disable (default) Bpdus sent 152, received 27562 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ----------------------------------------------------------Te 1/1 128.1223 128 20000 EDS 0 32768 0001.e800.a12b 128.
Enter the keyword bpduguard to disable the port when it receives a BPDU. shutdown-onviolation (OPTIONAL) Enter the keywords shutdown-on-violation to hardware disable an interface when a BPDU is received and the port is disabled. err-disable Enter the keywords err-disable to enable the port to be put into the errordisable state (EDS) if an error condition occurs. vlan vlan-range Enter the keyword vlan then the VLAN numbers. The range is from 1 to 4094.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added the optional Bridge Port Data Unit (BPDU) guard. 6.2.1.1 Introduced. The BPDU guard option prevents the port from participating in an active STP topology in case a BPDU appears on a port unintentionally, or is misconfigured, or is subject to a DOS attack. This option places the port into the Error Disable state if a BPDU appears, and a message is logged so that the administrator can take corrective action.
spanning-tree pvst err-disable Place ports in an Err-Disabled state if they receive a PVST+ BPDU when they are members an untagged VLAN. S4820T Syntax spanning-tree pvst err-disable cause invalid-pvst-bpdu Defaults Enabled; ports are placed in the Err-Disabled state if they receive a PVST+ BPDU when they are members of an untagged VLAN. Command Modes INTERFACE Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. vlan forward-delay — changes the time interval before Dell Networking OS transitions to the Forwarding state. vlan hello-time — change the time interval between BPDUs. vlan max-age — changes the time interval before PVST+ refreshes.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. vlan bridge-priority — sets the bridge-priority value. vlan hello-time — changes the time interval between BPDUs. vlan max-age — changes the time interval before PVST+ refreshes. show spanning-tree pvst — displays the PVST+ configuration. vlan hello-time Set the time interval between generation of PVST+ 7 BPDUs.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. vlan bridge-priority — sets the bridge-priority value. vlan forward-delay — changes the time interval before Dell Networking OS transitions to the forwarding state. vlan max-age — changes the time interval before PVST+ refreshes. show spanning-tree pvst — displays the PVST+ configuration.
Related Commands Version Description 6.2.1.1 Introduced. vlan bridge-priority — sets the bridge-priority value. vlan forward-delay — changes the time interval before Dell Networking OS transitions to the forwarding state. vlan hello-time — changes the time interval between BPDUs. show spanning-tree pvst — displays the PVST+ configuration.
46 Quality of Service (QoS) The Dell Networking operating software commands for quality of service (QoS) include traffic conditioning and congestion control. QoS commands are not universally supported on all Dell Networking Products. S4820T platform. This chapter contains the following sections: • Global Configuration Commands • Per-Port QoS Commands • Policy-Based QoS Commands Global Configuration Commands There is only one global configuration QoS command.
Version Description 8.3.1.0 Introduced. Per-Port QoS Commands Per-port QoS (port-based QoS) allows you to define the QoS configuration on a per-physical-port basis. dot1p-priority Assign a value to the IEEE 802.1p bits on the traffic this interface receives. Syntax dot1p-priority priority-value To delete the IEEE 802.1p configuration on the interface, use the no dot1p-priority command. Parameters priority-value Enter a value from 0 to 7.
Usage Information The dot1p-priority command changes the priority of incoming traffic on the interface. The system places traffic marked with a priority in the correct queue and processes that traffic according to its queue. When you set the priority for a port channel, the physical interfaces assigned to the port channel are configured with the same value. You cannot assign the dot1p-priority command to individual interfaces in a port channel.
On one interface, you can configure the rate police command for a VLAN or you can configure the rate police command for an interface. rate shape Shape the traffic output on the selected interface. S4820T Syntax Parameters rate shape [kbps] rate [burst-KB] kbps Enter the keyword kbps to specify the rate limit in Kilobits per second (Kbps). On S-Series, make the value a multiple of 64. The range is from 0 to 40000000. The default granularity is Megabits per second (Mbps).
Parameters Defaults queue Enter a value from 0 to 7. For each dot1p Priority, the default CoS queue value is: • Dot1p Priority : 0 1 2 3 4 5 6 7 • Queue : 2 0 1 3 4 5 6 7 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Command Modes Command History • INTERFACE • CONFIGURATION This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. After you configure a unicast queue as strict-priority, that particular queue, on the entire chassis, is treated as a strict-priority queue. Traffic for a strict priority is scheduled before any other queues are serviced. For example, if you send 100% line rate traffic over the SP queue, it starves all other queues on the ports on which this traffic is flowing.
Usage Information The unit of bandwidth percentage is 1%. If the sum of the bandwidth percentages given to all eight classes exceeds 100%, the bandwidth percentage automatically scales down to 100%. Related Commands qos-policy-output — creates a QoS output policy. class-map Create/access a class map. Class maps differentiate traffic so that you can apply separate quality-of-service policies to each class.
Usage Information Packets arriving at the input interface are checked against the match criteria and configured using this command to determine if the packet belongs to that class. This command accesses CLASS-MAP mode, where the configuration commands include thematch ip and match mac options. Related Commands ip access-list extended — configures an extended IP ACL. ip access-list standard — configures a standard IP ACL.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.18.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. show qos statistics — displays the QoS statistics. description Add a description to the selected policy map or QoS policy. S4820T Syntax description {description} To remove the description, use the no description {description} command.
match ip access-group Configure match criteria for a class map, based on the access control list (ACL). NOTE: IPv6 class-maps and IP-any class-maps do not match. This condition is true for IPv6 and IP-any class-maps on both ACLs as well as VLANs. S4820T Syntax match ip access-group access-group-name [set-ip-dscp value | set-color value] To remove ACL match criteria from a class map, use the no match ip access-group accessgroup-name [set-ip-dscp value | set-color value] command.
match ip dscp Use a differentiated services code point (DSCP) value as a match criteria. S4820T Syntax match {ip | ipv6 | ip-any} dscp dscp-list [set-ip-dscp value] To remove a DSCP value as a match criteria, use the no match {ip | ipv6 | ip-any} dscp dscp-list [[multicast] set-ip-dscp value] command. Parameters ip Enter the keyword ip to support IPv4 traffic. ipv6 Enter the keyword ipv6 to support IPv6 traffic. ip-any Enter the keyword ip-any to support IPv4 and IPv6 traffic.
match ip precedence Use IP precedence values as a match criteria. S4820T Syntax match {ip | ipv6 | ip-any} precedence ip-precedence-list [set-ip-dscp value] To remove IP precedence as a match criteria, use the no match {ip | ipv6 | ip-any} precedence ip-precedence-list [[multicast] set-ip-dscp value] command. Parameters ip Enter the keyword ip to support IPv4 traffic. ipv6 Enter the keyword ipv6 to support IPv6 traffic. ip-any Enter the keyword ip-any to support IPv4 and IPv6 traffic.
NOTE: Only one of the IP precedence values must be a successful match criterion, not all of the specified IP precedence values must match. Related Commands class-map — identifies the class map. match mac access-group Configure a match criterion for a class map, based on the contents of the designated MAC ACL. S4820T Syntax match mac access-group {mac-acl-name} Parameters mac-acl-name Enter a MAC ACL name. Its contents is used as the match criteria in the class map.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information To access this command, enter the class-map command. After the class map is identified, you can configure the match criteria. Related Commands class-map — identifies the class map.
policy-aggregate Allow an aggregate method of configuring per-port QoS via policy maps. An aggregate QoS policy is part of the policy map (output) applied on an interface. S4820T Syntax policy-aggregate qos-policy-name To remove a policy aggregate configuration, use the no policy-aggregate qos-policy-name command. Parameters qos-policy-name Enter the name of the policy map in character format (32 characters maximum).
layer2 (OPTIONAL) Enter the keyword layer2 to specify a Layer 2 Class Map. The default is Layer 3. Defaults Layer 3 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information To assign traffic to different flows using QoS policy, use the Output Policy map. This command enables Policy-Map-Output Configuration mode (conf-policy-map-out). Related Commands service-queue — assigns a class map and QoS policy to different queues. policy-aggregate — allows an aggregate method of configuring per-port QoS using policy maps.
When changing a Service-Queue configuration in a QoS policy map, all QoS rules are deleted and re-added automatically to ensure that the order of the rules is maintained. As a result, the Matched Packets value shown in the show qos statistics command is reset. Related Commands rate police — incoming traffic policing function. qos-policy-output Create a QoS output policy.
To return to the default, use the no queue egress multicast linecard {slot number port-set number | all} [wred-profile name | multicast-bandwidth percentage] command. Parameters linecard number Enter the keyword linecard then the line card slot number. port-set number Enter the keywords port-set then the line card’s port pipe. The range is from 0 or 1. all Enter the keyword all to apply to all line cards.
• When multicast bandwidth is assigned along with unicast bandwidth, first multicast bandwidth is reserved for that port, then the remaining unicast bandwidth configured is adjusted according to the bandwidth available after reserving for multicast bandwidth. queue ingress Assign a WRED Curve to all eight ingress Multicast queues or designate the percentage for the Multicast bandwidth queue.
rate-police Specify the policing functionality on incoming traffic. S4820T Syntax Parameters rate-police [kbps] committed-rate [burst-KB] [peak [kbps] peak-rate [burstKB]] kbps Enter the keyword kbps to specify the rate limit in Kilobits per second (Kbps). Make the following value a multiple of 64. The range is from 0 to 40000000. The default granularity is Megabits per second (Mbps). committed-rate Enter the bandwidth in Mbps. The range is from 0 to 40000.
Parameters kbps Enter the keyword kbps to specify the rate limit in Kilobits per second (Kbps). Make the following value a multiple of 64. The range is from 0 to 40000000. The default granularity is Megabits per second (Mbps). rate The range is from 10 to 40000. burst-KB (OPTIONAL) Enter the burst size in KB. The range is from 0 to 40000. The default is 100. Defaults Burst size is 10KB. Granularity for rate is Mbps unless you use the kbps option.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Usage Information A single policy-map can be attached to one or more interfaces to specify the service-policy for those interfaces. Related Commands policy-map-output — creates an output policy map. service-queue Assign a class map and QoS policy to different queues. S4820T Syntax service-queue queue-id [class-map class-map-name] [qos-policy qos-policyname] To remove the queue assignment, use the no service-queue queue-id [class-map classmap-name] [qos-policy qos-policy-name] command.
service-policy output — applies an output policy map to the selected interface. set Mark outgoing traffic with a differentiated service code point (DSCP) or dot1p value. S4820T Syntax Parameters set {ip-dscp value | mac-dot1p value} ip-dscp value (OPTIONAL) Enter the keywords ip-dscp then the IP DSCP value. The range is from 0 to 63. mac-dot1p value Enter the keywords mac-dot1p then the dot1p value. The range is from 0 to 7.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Dell#show qos class-map Class-map match-any CM Match ip access-group ACL Related Commands class-map — identifies the class map.
Parameters summary interface detail Defaults Command Modes Command History To view a policy map interface summary, enter the keyword summary and optionally one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
1 2 3 Dell# Example (Summary IPv4) c1 c2 c3 q1 q2 q3 Dell#sho qos policy-map summary Interface policy-map-input policy-map-output Te 4/1 PM1 Te 4/2 PM2 PMOut Dell# show qos policy-map-input View the input QoS policy map details. S4820T Syntax show qos policy-map-input [policy-map-name] [class class-map-name] [qospolicy-input qos-policy-name] Parameters Defaults policy-map-name Enter the policy map name. class class-mapname Enter the keyword class then the class map name.
show qos policy-map-output View the output QoS policy map details. S4820T Syntax Parameters Defaults Command Modes Command History show qos policy-map-output [policy-map-name] [qos-policy-output qos-policyname] policy-map-name Enter the policy map name. qos-policy-output qos-policy-name Enter the keyword qos-policy-output then the QoS policy name. none • EXEC • EXEC Privilege This guide is platform-specific.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Example Dell#show qos qos-policy-output Qos-policy-output qosOut Rate-limit 50 50 peak 50 50 Wred yellow 1 Wred green 1 show qos statistics View QoS statistics.
Related Command Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. clear hardware stack-unit - Clear statistics from selected hardware components. show qos wred-profile View the WRED profile details. S4820T Syntax show qos wred-profile wred-profile-name Parameters Defaults wred-profile-name Enter the WRED profile name to view the profile details.
test cam-usage Check the Input Policy Map configuration for the CAM usage. S4820T Syntax Parameters test cam-usage service-policy input policy-map stack-unit {[number port-set portpipe number] | [all]} policy-map Enter the policy map name. stack-unitnumber (OPTIONAL) Enter the keyword stack-unit then the stack-unit slot number. port-set portpipe number Enter the keywords port-set then the stack-unit port pipe number. The range is from 0 or 1.
Field Description NOTE: The CAM entries reserved for the default rules are not included in the Available CAM column; free entries, from the default rules space, cannot be used as a policy map for the classification rules. Estimated CAM per Port Indicates the number of free CAM entries required (for the classification rules) to apply the input policy map on a single interface.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. When you configure trust, matched bytes/packets counters are not incremented in the show qos statistics command. Dynamic mapping honors packets marked according to the standard definitions of DSCP. The following lists the default mapping.
profile-name Enter your WRED profile name in character format (32 character maximum). Or use one of the five pre-defined WRED profile names. Pre-defined Profiles: wred_drop, wred-ge_y, wred_ge_g, wred_teng_y, wred_teng_. Defaults When WRED green is applied, default WRED yellow profiles take effect and vice-versa. Command Modes CONFIGURATION (conf-qos-policy-out) Command History This guide is platform-specific.
Usage Information Version Description 8.3.19.0 Introduced on the S4820t. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. When you enable wred ecn, and the number of packets in the queue is below the minimum threshold, packets are transmitted per the usual WRED treatment.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information Use the default pre-defined profiles or configure your own profile. You cannot delete the pre-defined profiles or their default values. This command enables WRED configuration mode —(conf-wred).
Usage Information Version Description 9.5.0.0 Introduced on the Z9000, S6000, S4820T, S4810, and MXL. If the specified color-map does not exist, the Diffserv Manager (DSM) creates a color map and sets all the DSCP values to green (low drop precedence). The default setting for each DSCP value (0-63) is green (low drop precedence). This command allows setting the number of specific DSCP values to yellow or red.
the DSCP color map that is being used by one or more interfaces, remove the DSCP map from each interface. Example Dell(conf)#qos dscp-color-map mymap Related Commands qos dscp-color-map— associates the DSCP color map profile with an interface so that all IP packets received on it is given a color based on that color map dscp— sets the number of specific DSCP values for color map profile to yellow or red.
show qos dscp-color-policy Display DSCP color policy configuration for one or all interfaces. Syntax show qos dscp-color-policy {summary [interface] | detail {interface}} Parameters summary Enter the summary keyword to display summary information about a color policy on one or more interfaces. Detail Enter the detail keyword to display detailed information about a color policy on one or more interfaces. interface Enter the name of the interface that has color policy configured.
show qos dscp-color-map Display the DSCP color map for one or all interfaces. Syntax Parameters show qos dscp-color-map map-name map-name Enter the name of the color map. Defaults None Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
47 Routing Information Protocol (RIP) Routing information protocol (RIP) is a distance vector routing protocol. The Dell Networking operating software supports both RIP version 1 (RIPv1) and RIP version 2 (RIPv2) on the S4820T platform. The Dell Networking OS implementation of RIP is based on IETF RFCs 2453 and RFC 1058. For more information about configuring RIP, refer to the Dell Networking OS Configuration Guide.
clear ip rip Update all the RIP routes in the Dell Networking OS routing table. S4820T Syntax clear ip rip Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.
database (OPTIONAL) Enter the keyword database to display messages when there is a change to the RIP database. events (OPTIONAL) Enter the keyword events to debug only RIP protocol changes. trigger (OPTIONAL) Enter the keyword trigger to debug only RIP trigger extensions. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information This command ensures that route information being redistributed is converted to the same metric value. Related Commands redistribute — allows you to redistribute routes learned by other methods. description Enter a description of the RIP routing protocol.
distance Assign a weight (for prioritization) to all routes in the RIP routing table or to a specific route. Lower weights (“administrative distance”) are preferred. S4820T Syntax distance weight [ip-address mask [prefix-name]] To return to the default values, use the no distance weight [ip-address mask] command. Parameters weight Enter a number from 1 to 255 for the weight (for prioritization). The default is 120. ip-address (OPTIONAL) Enter the IP address, in dotted decimal format (A.B.C.
To delete the filter, use the no distribute-list prefix-list-name in command. Parameters prefix-list-name Enter the name of a configured prefix list. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
To delete the filter, use the no distribute-list prefix-list-name out command. Parameters prefix-list-name Enter the name of a configured prefix list. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
ip poison-reverse Set the prefix of the RIP routing updates to the RIP infinity value. S4820T Syntax ip poison-reverse To disable poison reverse, use the no ip poison-reverse command. Defaults Disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information To enable the interface to send both version of RIP packets, use the ip rip send version 1 2 command.
Related Commands Version Description pre- 6.2.1.1 Introduced on the E-Series. ip poison-reverse — sets the prefix for RIP routing updates. maximum-paths Set RIP to forward packets over multiple paths. S4820T Syntax maximum-paths number To return to the default values, use the no maximum-paths commands. Parameters number Enter the number of paths. The range is from 1 to 16. The default is 4 paths. Defaults 4 Command Modes ROUTER RIP Command History This guide is platform-specific.
To delete a neighbor setting, use the no neighbor ip-address command. Parameters ip-address Enter the IP address, in dotted decimal format, of a router with which to exchange information. Defaults Not configured. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Defaults Not configured. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. This command is intended for low-speed interfaces. passive-interface Suppress routing updates on a specified interface.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information Although the passive interface does not send or receive routing updates, the network on that interface still includes in RIP updates sent using other interfaces.
Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information To redistribute the default route (0.0.0.0/0), configure the default-information originate command. Related Commands default-information originate — generates a default route for RIP traffic. redistribute isis Redistribute routing information from an IS-IS instance.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. pre- 6.2.1.1 Introduced on the E-Series. redistribute ospf Redistribute routing information from an OSPF process. S4820T Syntax redistribute ospf process-id [match external {1 | 2} | match internal | metric metric-value] [route-map map-name] To disable redistribution, use the no redistribute ospf process-id [match external {1 | 2} | match internal | metric metric-value] [route-map map-name] command.
Version Description 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. router rip To configure and enable RIP, enter ROUTER RIP mode. S4820T Syntax router rip To disable RIP, use the no router rip command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show config Display the changes you made to the RIP configuration. The default values are not shown. S4820T Syntax show config Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
show running-config rip Display the current RIP configuration. S4820T Syntax show running-config rip Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.
Defaults invalid Enter the number of seconds to specify the time interval before routing updates are declared invalid or expired. The invalid value should be at least three times the update timer value. The range is from zero (0) to 4294967295. The default is 180 seconds. holddown Enter the number of seconds to specify a time interval during which the route is marked as unreachable but still sending RIP packets. The holddown value should be at least three times the update timer value.
To return to the default version setting, use the no version command. Parameters 1 Enter the keyword 1 to specify RIP version 1. 2 Enter the keyword 2 to specify RIP version 2. Defaults The Dell Networking OS sends RIPv1 and receives RIPv1 and RIPv2. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
48 Remote Monitoring (RMON) The Dell Networking operating software remote monitoring (RMON) is implemented on the S4820T platform. Dell Networking OS RMON is based on IEEE standards, providing both 32-bit and 64-bit monitoring and long-term statistics collection.
interval Time, in seconds, the alarm monitors the MIB variables; this is the alarmSampleType in the RMON alarm table. The range is from 5 to 3600 seconds. delta Enter the keyword delta to test the change between MIB variables. This is the alarmSampleType in the RMON alarm table. absolute Enter the keyword absolute to test each MIB variable directly. This is the alarmSampleType in the RMON alarm table.
rmon collection history Enable the RMON MIB history group of statistics collection on an interface. S4820T Syntax rmon collection history {controlEntry integer} [owner name] [buckets number] [interval seconds] To remove a specified RMON history group of statistics collection, use the no rmon collection history {controlEntry integer} command. Parameters controlEntry integer Enter the keyword controlEntry to specify the RMON group of statistics using a value.
rmon collection statistics Enable RMON MIB statistics collection on an interface. S4820T Syntax rmon collection statistics {controlEntry integer} [owner name] To remove RMON MIB statistics collection on an interface, use the no rmon collection statistics {controlEntry integer} command. Parameters controlEntry integer Enter the keyword controlEntry to specify the RMON group of statistics using a value. Then enter an integer value from 1 to 65535 that identifies the RMON Statistic Table.
Parameters number Assign an event number in integer format. The range is from 1 to 65535. You must ensure that the value you enter is unique in the RMON event table. log (OPTIONAL) Enter the keyword log to generate an RMON event log. This option sets the eventType to either log or log-and-snmptrap in the RMON event table. The default is None. trap community (OPTIONAL) Enter the keyword trap followed by the SNMP community string to generate SNMP traps for an RMON event entry.
variable The MIB object to monitor. The variable must be in the SNMP OID format; for example, 1.3.6.1.2.1.1.3 The object type must be a 64-bit integer. interval Time, in seconds, the alarm monitors the MIB variables; this is the alarmSampleType in the RMON alarm table. The range is from 5 to 3600 seconds. delta Enter the keyword delta to test the change between MIB variables. This is the alarmSampleType in the RMON alarm table. absolute Enter the keyword absolute to test each MIB variable directly.
show rmon Display the RMON running status including the memory usage. S4820T Syntax show rmon Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
show rmon events Display the contents of the RMON event table. S4820T Syntax Parameters show rmon events [index] [brief] index (OPTIONAL) Enter the table index number to display just that entry. brief (OPTIONAL) Enter the keyword brief to display the RMON event table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
event owner: event status: OK RMON event entry 114 description: event type: LOG and SNMP TRAP. event community: public event last time sent: none event owner: event status: OK Example (Brief) Dell#show rmon event brief index description -----------------------------1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 Dell# show rmon hc-alarm Display the contents of RMON High-Capacity alarm table.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. Example (Index) Dell#show rmon hc-alarm 1 RMON high-capacity alarm entry 2 object: 1.3.6.1.2.1.2.2.1.4.2099844 sample interval: 10 sample type: delta value.
Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
brief (OPTIONAL) Enter the keyword brief to display the RMON log table in an easyto-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
brief (OPTIONAL) Enter the keyword brief to display the RMON Ethernet statistics table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example (Index) 1300 Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
HC 512-1023 bytes packets: 0 HC 1024-1518 bytes packets overflow: 0 HC 1024-1518 bytes packets: 0 Dell# Example (Brief) Dell#show rmon statistics br index ifIndex interface ---------------------------------------6001 100974631 TenGigabitEthernet 2/2 6002 100974631 TenGigabitEthernet 2/2 6003 101236775 TenGigabitEthernet 2/1 6004 101236775 TenGigabitEthernet 2/1 9001 134529054 TenGigabitEthernet 3/2 9002 134529054 TenGigabitEthernet 3/2 9003 134791198 TenGigabitEthernet 3/1 9004 134791198 TenGigabitEthernet
49 Rapid Spanning Tree Protocol (RSTP) The Dell Networking operating software implementation of rapid spanning tree protocol (RSTP) is based on the IEEE 802.1w standard spanning-tree protocol. The RSTP algorithm configures connectivity throughout a bridged local area network (LAN) that is comprised of LANs interconnected by bridges. Dell Networking OS supports RSTP. bridge-priority Set the bridge priority for RSTP.
debug spanning-tree rstp Enable debugging of RSTP and view information on the protocol. Syntax debug spanning-tree rstp [all | bpdu interface {in | out} | events] To disable debugging, use the no debug spanning-tree rstp command. Parameters all (OPTIONAL) Enter the keyword all to debug all spanning tree operations. bpdu interface {in | out} (OPTIONAL) Enter the keyword bpdu to debug the bridge protocol data units.
description Enter a description of the rapid spanning tree. Syntax description {description} To remove the description, use the no description {description} command. Parameters description Enter a description to identify the rapid spanning tree (80 characters maximum). Defaults none Command Modes SPANNING TREE (The prompt is “config-rstp”.) Command History This guide is platform-specific.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. protocol spanning-tree rstp — enters SPANNING TREE mode on the switch. forward-delay Configure the amount of time the interface waits in the Listening State and the Learning State before transitioning to the Forwarding State.
hello-time Set the time interval between the generation of the RSTP bridge protocol data units (BPDUs). Syntax hello-time [milli-second] seconds To return to the default value, use the no hello-time command. Parameters seconds Enter a number as the time interval between transmission of BPDUs. The range is from 1 to 10 seconds. The default is 2 seconds. milli-second Enter the keywords milli-second to configure a hello time on the order of milliseconds.
max-age To maintain configuration information before refreshing that information, set the time interval for the RSTP bridge. Syntax max-age seconds To return to the default values, use the no max-age command. Parameters max-age Enter a number of seconds the Dell Networking OS waits before refreshing configuration information. The range is from 6 to 40 seconds. The default is 20 seconds.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information RSTP is not enabled when you enter RSTP mode.
no disable bridge-priority 16384 show spanning-tree rstp Display the RSTP configuration. Syntax Parameters Command Modes Command History Usage Information Example (Brief) show spanning-tree rstp [brief] [guard] brief (OPTIONAL) Enter the keyword brief to view a synopsis of the RSTP configuration information. guard (OPTIONAL) Enter the keyword guard to display the type of guard enabled on an RSTP interface and the current port state. • EXEC • EXEC Privilege Version Description 9.7(0.
Root ID Priority 8192, Address 0001.e805.e306 Root Bridge hello time 4, max age 20, forward delay 15 Bridge ID Priority 16384, Address 0001.e801.6aa8 Configured hello time 2, max age 20, forward delay 15 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ---------- ------- --- ------- -------------------- -------Te 4/2 128.418 128 20000 FWD 20000 16384 0001.e801.6aa8 128.418 Te 4/1 128.419 128 20000 FWD 20000 16384 0001.e801.6aa8 128.419 Te 4/8 128.426 128 20000 FWD 20000 8192 0001.e805.
spanning-tree rstp Configure an RSTP interface with one of these settings: port cost, edge port with optional bridge port data unit (BPDU) guard, port priority, loop guard, or root guard. Syntax Parameters spanning-tree rstp {cost port-cost | edge-port [bpduguard [shutdown-onviolation]] | priority priority | {loopguard | rootguard}} cost port-cost Enter the keyword cost then the port cost value. The range is from 1 to 200000.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.4.2.1 Added support for the optional guard keyword on the C-Series, S-Series, and ESeries TeraScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced the hardware shutdown-on-violation options. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added the optional bridge port data unit (BPDU) guard. 6.2.1.1 Introduced on the E-Series.
tc-flush-standard Enable the MAC address flushing after receiving every topology change notification. Syntax tc-flush-standard To disable, use the no tc-flush-standard command. Defaults Disabled Command Modes CONFIGURATION (conf-rstp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
50 Software-Defined Networking (SDN) Dell Networking operating software supports Software-Defined Networking (SDN). For more information, refer to the SDN Deployment Guide.
51 Security The commands in this chapter are available on Dell Networking OS. This chapter contains various types of security commands offered in the Dell Networking operating software. The commands are listed in the following sections: • AAA Accounting Commands • Authorization and Privilege Commands • Authentication and Password Commands • RADIUS Commands • TACACS+ Commands • Port Authentication (802.
commands {level | role role-name Enter the keyword command then a privilege level for accounting of commands executed at that privilege level or enter the keyword role then the role name for accounting of commands executed by a user with that user role. name | default Enter one of the following: • For name, enter a user-defined name of a list of accounting methods. • For default, the default accounting methods used.
Dell(conf)# aaa accounting command role secaadmin default start-stop tacacs + Related Commands enable password — changes the password for the enable command. login authentication — enables AAA login authentication on the terminal lines. password — creates a password. tacacs-server host — specifies a TACACS+ server host. aaa accounting suppress Prevent the generation of accounting records of users with the user name value of NULL.
accounting Apply an accounting method list to terminal lines. S4820T Syntax accounting {exec | commands {level | role role-name} method-list Parameters exec Enter the keyword exec to apply an EXEC level accounting method list. commands {level | role role-name} Enter the keywords commands level to apply an EXEC and CONFIGURATION level accounting method list by enter the keyword role and then the role name for accounting of commands executed by a user with that user role.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
method-list Enter a method list that you defined using the aaa accounting exec or aaa accounting commands. Defaults none Command Modes LINE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.
tacacs+ Use the TACACS+ protocol to perform authorization. none Enter the keyword none to apply no authorization. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the E-Series. By default, the aaa authorization commands command configures the system to check both EXEC level and CONFIGURATION level commands. Use the command no aaa authorization configcommands to enable only EXEC-level command checking. aaa authorization exec Set parameters that restrict (or permit) a user’s access to EXEC-level commands.
To delete access to a level and command, use the no privilege mode level level command command. Parameters mode level level Enter one of the following keywords as the mode for which you are controlling access: • configure for CONFIGURATION mode • exec for EXEC mode • interface for INTERFACE modes • line for LINE mode • route-map for ROUTE-MAP mode • router for ROUTER OSPF, ROUTER RIP, ROUTER ISIS and ROUTER BGP modes Enter the keyword level then a number for the access level.
privilege level (LINE mode) Change the access level for users on the terminal lines. Syntax privilege level level To delete access to a terminal line, use the no privilege level level command. Parameters level level Enter the keyword level then a number for the access level. The range is from 0 to 15. Level 1 is EXEC mode and Level 15 allows access to all CLI modes. Defaults level = 15 Command Modes LINE Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Introduced on the S4810, S4820T, S5000, S6000, Z9000, Z9500, MXL By default, the service password-encryption command stores encrypted passwords.
method-list-name Enter a text string (up to 16 characters long) to name the list of enabled authentication methods activated at login. method Enter one of the following methods: ... method2 • enable: use the password the enable password command defines in CONFIGURATION mode. • line: use the password the password command defines in LINE mode. • none: no authentication. • radius: use the RADIUS servers configured with the radius-server host command.
radius-server host — specifies a RADIUS server host. tacacs-server host — specifies a TACACS+ server host. aaa authentication login Configure AAA Authentication method lists for user access to EXEC mode (Enable log-in). S4820T Syntax aaa authentication login {method-list-name | default} method [... method4] To return to the default setting, use the no aaa authentication login {method-list-name | default} command.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. By default, the locally configured username password is used. If you configure aaa authentication login default, Dell Networking OS uses the methods this command defines for login instead.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. line — applies an authentication method list to the designated terminal lines.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. To control access to command modes, use this command to define a password for a level and use the privilege level (CONFIGURATION mode) command.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Only Dell Networking Technical Support staff use this command.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. To control access to command modes, use this command to define a password for a level and use the privilege level (CONFIGURATION mode) command. Passwords must meet the following criteria: • Start with a letter, not a number.
Usage Information Related Commands Version Description 9.6.0.0 Revised introductory and usage guidelines description. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information Dell Networking OS prompts users for these passwords when the method for authentication or authorization used is "line".
upper number (OPTIONAL) Enter the keyword upper then the upper number. The range is from 0 to 31. lower number (OPTIONAL) Enter the keyword lower then the lower number. The range is from 0 to 31. numeric number (OPTIONAL) Enter the keyword numeric then the numeric number. The range is from 0 to 31. special-char number (OPTIONAL) Enter the keywords special-char then the number of special characters permitted. The range is from 0 to 31. The following special characters are supported: !"#%&'();<=>?[\]*+
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Example Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Dell#show privilege Current privilege level is 15. Dell# Dell#show privilege Current privilege level is 14. Dell# Dell#show privilege Current privilege level is 10. Dell# Related Commands privilege level (CONFIGURATION mode) — assigns access control to different command modes. show users Allows you to view information on all users logged in to the switch.
Example Field Description Line Displays the terminal lines currently in use. User Displays the user name of all users logged in. Host(s) Displays the terminal line status. Location Displays the IP address of the user. Dell# show users Authorization Mode: role or privilege Line User Host(s) Location * 0 console 0 2 vty 0 admin idle 10.16.127.35 3 vty 1 ad idle 10.16.127.145 4 vty 2 ad1 idle 10.16.127.141 5 vty 3 ad1 idle 10.16.127.145 6 vty 4 admin idle 10.16.127.141 7 vty 5 ad idle 10.16.127.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. The software measures the period of inactivity defined in this command as the period between consecutive keystrokes. For example, if your password is “password” you can enter “p” and wait 29 seconds to enter the next letter.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.0) Added support for roles on the Z9000, S6000, S4820T, S4810, MXL. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Introduced on the S-Series and Z-Series.
ip radius source-interface Specify an interface’s IP address as the source IP address for RADIUS connections. Syntax ip radius source-interface interface To delete a source interface, use the no ip radius source-interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Parameters seconds Enter a number of seconds during which non-responsive RADIUS servers are skipped. The range is from 0 to 2147483647 seconds. The default is 0 seconds. Defaults 0 seconds Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
radius-server vrf vrf1 source-interface TenGigabitEthernet 1/36 radius-server host 1.1.1.1 key 7 9a2f3ec0c65c6f41 radius-server host 2.2.2.2 key 7 9a2f3ec0c65c6f41 Dell(conf-radius-group)# Related Commands login authentication — sets the database to be checked when a user logs in. radius-server key — sets an authentication key for RADIUS communications. radius-server retransmit — sets the number of times the RADIUS server attempts to send information.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added support for IPv6. 8.3.7.0 Introduced on the S4810. 7.
radius-server key Configure a key for all RADIUS communications between the switch and the RADIUS host server. Syntax radius-server key [encryption-type] key To delete a password, use the no radius-server key command. Parameters encryption-type key (OPTIONAL) Enter either zero (0) or 7 as the encryption type for the key entered. The options are: • 0 is the default and means the key is not encrypted and stored as clear text. • 7 means that the key is encrypted and hidden.
To configure zero retransmit attempts, use the no radius-server retransmit command. To return to the default setting, use the radius-server retransmit 3 command. Parameters retries Enter a number of attempts that FTOS tries to locate a RADIUS server. The range is from zero (0) to 100. The default is 3 retries. Defaults 3 retries Command Modes CONFIGURATION Command History This guide is platform-specific.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. radius-server host — configures a RADIUS host. radius-server vrf Create an association between a RADIUS server group and a VRF and source interface.
Usage Information Version Description 9.4(0.0) Introduced on the S-Series and Z9000. You can use this command to associate a group of RADIUS servers with a VRF and source interface. You can configure the source interface only with the VRF attribute and source interface is optional with the VRF attributes. If VRF is not configured on the RADIUS group, then the group is considered to be on the default VRF.
Version Description 9.4.(0.0) Introduced on the S-Series and Z-Series. Usage Information If the TACACS group is not configured for Authentication, Authorization, and Accounting, then globally configured TACACS servers are used for the purposes. When the TACACS group is removed, the AAA configuration is also removed. Example Dell(conf)#tacacs-server group group1 Dell(conf-tacacs-group)#tacacs-server host 1.1.1.1 key secret Dell(conf-tacacs-group)#tacacs-server host 2.2.2.
To delete a source interface, use the no ip tacacs source-interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Introduced on the S-Series and Z-Series. Usage Information You can associate a TACACS server group with a VRF.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added support for IPv6. 8.3.7.0 Introduced on the S4810. 7.
To delete the association between a TACACS server group and a VRF and source interface, use the no tacacs-server vrf vrf-name [source-interface interface] command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to associate a TACACS server group with that VRF. interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
tacacs-server key Configure a key for communication between a TACACS+ server and a client. Syntax tacacs-server key [encryption-type] key To delete a key, use the no tacacs-server key key command. Parameters encryption-type key (OPTIONAL) Enter either zero (0) or 7 as the encryption type for the key entered. The options are: • 0 is the default and means the key is not encrypted and stored as clear text. • 7 means that the key is encrypted and hidden.
Important Points to Remember Dell Networking OS limits network access for certain users by using VLAN assignments. 802.1X with VLAN assignment has these characteristics when configured on the switch and the RADIUS server. • 802.1X is supported on Dell Networking OS. • 802.1X is not supported on the LAG or the channel members of a LAG. • If no VLAN is supplied by the RADIUS server or if 802.1X authorization is disabled, the port is configured in its access VLAN after successful authentication.
dot1x authentication (Interface) Enable dot1x on an interface; dot1x must be enabled both globally and at the interface level. Syntax dot1x authentication To disable dot1x on an interface, use the no dot1x authentication command. Defaults Disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series, S-Series, and E-Series. If the host responds to 802.1X with an incorrect login/password, the login fails. The switch attempts to authenticate again until the maximum attempts configured is reached.
dot1x guest-vlan Configure a guest VLAN for limited access users or for devices that are not 802.1X capable. Syntax dot1x guest-vlan vlan-id To disable the guest VLAN, use the no dot1x guest-vlan vlan-id command. Parameters vlan-id Enter the VLAN Identifier. The range is from 1 to 4094. Defaults Not configured. Command Modes CONFIGURATION (conf-if-interface-slot/port) Command History This guide is platform-specific.
dot1x mac-auth-bypass Enable MAC authentication bypass. If 802.1X times out because the host did not respond to the Identity Request frame, Dell Networking OS attempts to authenticate the host based on its MAC address. Syntax [no] dot1x mac-auth-bypass Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. interface range — configures a range of interfaces. dot1x port-control Enable port control on an interface. Syntax Parameters dot1x port-control {force-authorized | auto | force-unauthorized} force-authorized Enter the keywords force-authorized to forcibly authorize a port.
Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Related Commands interface range — configures a range of interfaces. dot1x reauth-max Configure the maximum number of times a port can re-authenticate before the port becomes unauthorized. Syntax dot1x reauth-max number To return to the default, use the no dot1x reauth-max command. Parameters number Enter the permitted number of re-authentications. The range is from 1 to 10. The default is 2. Defaults 2 Command Modes INTERFACE Command History This guide is platform-specific.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x supplicant-timeout Configure the amount of time after which exchanges with the supplicant time-out. Syntax dot1x supplicant-timeout seconds To return to the default, use theno dot1x supplicant-timeout command.
Parameters seconds Enter the interval time, in seconds, that EAPOL PDUs are transmitted. The range is from 1 to 65535 (1 year). The default is 30. Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON.
Example Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series, S-Series, and E-Series. Dell#show dot1x interface fortyGigE 1/48 802.
Backend State: Dell# Initialize SSH Server and SCP Commands Dell Networking OS supports secure shell (SSH) protocol versions 1.5 and 2.0. SSH is a protocol for secure remote login over an insecure network. SSH sessions are encrypted and use authentication. The SSH server and client are enhanced to support the VRF awareness functionality. Using this capability, an SSH client or server can use a VRF instance name to look up the correct routing table and establish a connection.
This command requires user interaction and generates a prompt prior to overwriting any existing host keys. NOTE: Only a user with superuser permissions should generate host-keys. Example Dell(conf)#crypto key generate rsa Enter key size <1024-2048>. Default<1024> : Host key already exists. Overwrite (y/n)?y Generating 1024-bit SSHv2 RSA key. ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! Dell(conf)# Dell(conf)#crypto key generate rsa1 Enter key size <1024-2048>.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series.
Usage Information To configure the switch as an SCP server, use the ip ssh server command. Related Commands ip ssh server — enables the SSH and SCP server on the switch. ip ssh authentication-retries Configure the maximum number of attempts that should be used to authenticate a user. Syntax ip ssh authentication-retries 1-10 Parameters 1-10 Enter the number of maximum retries to authenticate a user. The range is from 1 to 10. The default is 3.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. ip ssh hostbased-authentication Enable hostbased-authentication for the SSHv2 server.
• checking client host-keys is done with the file specified in the ip ssh pub-key-file command. NOTE: Administrators must specify the two files (rhosts and pub-key-file) to configure host-based authentication. Related Commands ip ssh pub-key-file — public keys of trusted hosts from a file. ip ssh rhostsfile — trusted hosts and users for rhost authentication. ip ssh key-size Configure the size of the server-generated RSA SSHv1 key.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Usage Information This command specifies the file used for the host-based authentication. The creates/ file overwrites the flash://ADMIN_DIR/ssh/knownhosts file and deletes the user-specified file. Even though this command is a global configuration command, it does not appear in the running configuration because you only need to run this command once. The file contains the OpenSSH-compatible public keys of the host for which host-based authentication is allowed.
ip ssh rhostsfile Specify the rhost file used for host-based authorization. Syntax Parameters ip ssh rhostsfile {WORD} WORD Enter the rhost file name for the host-based authentication. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.
Parameters enable Enter the keyword enable to enable RSA authentication for the SSHv2 server. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Version Description 9.4(0.0) Introduced on the S-Series and Z9000. Usage Information If you configure a VRF for an SSH session, then you need not explicitly mention the same VRF for the SSH client sessions intended for that VRF. The vrf attribute in the ip ssh vrf command is applicable for both the SSH client as well as the COPY (SCP) commands. Example Dell(conf)#ip ssh vrf vrf1 Dell(conf)#do ssh 10.10.10.
Example Dell(conf)#ip ssh source-interface tengigabitethernet 1/42 Dell(conf)#do ssh 10.10.10.2 -l admin Dell(conf)#no ip ssh source-interface ip ssh server Configure an SSH server. SSH server is enabled by default. S4820T Syntax NOTE: Some of the parameters in this command require licensing to access. For more information, contact your Dell Networking representative.
The following HMAC algorithms are available: • hmac-sha1 • hmac-sha1-96 • hmac-sha2-256 • hmac-sha2-256-96 When FIPS is enabled, the default HMAC algorithm is hmac-sha1-96. When FIPS is not enabled, the default HMAC algorithms are the following: kex key-exchangealgorithm • hmac-md5 • hmac-md5-96 • hmac-sha1 • hmac-sha1-96 • hmac-sha2-256 • hmac-sha2-256-96 Enter the keyword kex and then a space-delimited list of key exchange algorithms supported by the SSH server.
• When FIPS is not enabled, the default is hmac-md5,hmac-md5-96,hmac-sha1,hmac-sha1-96,hmacsha2-256,hmac-sha2-256-96. • When FIPS is enabled, the default is diffie-hellman-group14-sha1. • When FIPS is not enabled, the default is diffie-hellman-group-exchange-sha1,diffie-hellman-group1sha1,diffie-hellman-group14-sha1. Command Modes CONFIGURATION Command History This guide is platform-specific.
Parameters vrf management Enter the key word vrf followed by the keyword management to configure an SSH server on a management VRF. vrf vrf-name Enter the key word vrf followed by the VRF name to configure an SSH server on that VRF. Defaults None Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Example Dell#show ip ssh SSH server : enabled. SSH server version : v1 and v2. SSH server vrf : default. SSH server ciphers : 3des-cbc,aes128-cbc,aes192-cbc,aes256cbc,aes128-ctr,aes192-ctr,aes256-ctr. SSH server macs : hmac-md5,hmac-md5-96,hmac-sha1,hmacsha1-96,hmac-sha2-256,hmac-sha2-256-96.
Version Description pre-6.1.1.0 Introduced on the E-Series. Usage Information This command displays the contents of the flash://ADMIN_DIRssh/knownhosts file. Example Dell# show ip ssh client-pub-keys 4.8.1.2 ssh-rsa AAAAB3NzaC1yc2EAAAABIwAAAIEAu5NoTbmnLxBknaeXZmUJMupNwNUoGlo1/ yLPI5eehQTyaldRPHtGyPlcmMbCH +QJkqtyiwDPmH4njyDMYDCXY85vc55ibWsN9qalagklnh2cj2q4nYj5x8+8OOhYeFPaHiygd8U/ FXict61jWs84Co1UTsAgRzDJ9aUSS75TVac= root@dt-maa-linux-1.force10networks.
Usage Information This command displays the contents of the flash:/ADMIN_DIR/ssh/authorized-keys.username file. Example Dell#show ip ssh rsa-authentication my-authorized-keys ssh-rsa AAAAB3NzaC1yc2EAAAABIwAAAIEAyB17l4gFp4r2DRHIvMc1VZd0Sg5GQxRV1y1X1JOMeO6Nd0WuYyzrQMM 4qJAoBwtneOXfLBcHF3V2hcMIqaZN+CRCnw/ zCMlnCf0+qVTd1oofsea5r09kS0xTp0CNfHXZ3NuGCq9Ov33m9+U9tMwhS8vy8AVxdH4x4km3c3t5Jvc= freedom@poclab4 Dell# Related Commands ip ssh rsa-authentication (Config) — configures the RSA authorized keys.
• aes256-ctr : Force ssh to use aes256-ctr encryption cipher -l username (OPTIONAL) Enter the keyword -l then the user name used in this SSH session. The default is the user name of the user associated with the terminal. -m HMAC algorithm Enter one of the following HMAC algorithms to use. (For v2 clients only): "no fips mode enable"(disable) will support v1 & v2 client. • hmac-md5: Force ssh to use hmac-md5 HMAC algorithm. • hmac-md5-96: Force ssh to use hmac-md5-96 HMAC algorithm.
anvltest@10.16.151.48's password: Last login: Thu Jan 5 00:17:47 2012 from login-maa-101 [anvltest@dt-maa-linux-1 ~]# exit logout Dell# Dell#ssh vrf vrf1 10.10.10.2 -l admin Secure DHCP Commands DHCP as defined by RFC 2131 provides no authentication or security mechanisms. Secure DHCP is a suite of features that protects networks that use dynamic address allocation from spoofing and attacks. clear ip dhcp snooping Clear the DHCP binding table.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
ip dhcp snooping binding Create a static entry in the DHCP binding table. Syntax Parameters Defaults Command Modes Command History [no] ip dhcp snooping binding mac address vlan-id vlan-id ip ip-address interface type slot/port lease number mac address Enter the keyword mac then the MAC address of the host to which the server is leasing the IP address. vlan-id vlan-id Enter the keywords vlan-id then the VLAN to which the host belongs. The range is from 2 to 4094.
ip dhcp snooping database Delay writing the binding table for a specified time. Syntax ip dhcp snooping database write-delay minutes Parameters minutes The range is from 5 to 21600. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.
ip dhcp snooping trust Configure an interface as trusted. Syntax [no] ip dhcp snooping trust Defaults Untrusted Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
ip dhcp snooping vlan Enable DHCP Snooping on one or more VLANs. Syntax [no] ip dhcp snooping vlan name Parameters name Enter the name of a VLAN on which to enable DHCP Snooping. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. clear ip dhcp snooping — clears the contents of the DHCP binding table. Role-Based Access Control Commands With Role-Based Access Control (RBAC), access and authorization is controlled based on a user’s role. Users are granted permissions based on their user roles, not on their individual user ID.
Before you enable role-based only AAA authorization: Related Commands 1. Locally define a system administrator user role.This will give you access to login with full permissions even if network connectivity to remote authentication servers is not available. 2. Configure login authentication on the console. This ensures that all users are properly identified through authentication no matter the access point 3. Specify an authentication method (RADIUS, TACACS+, or Local). 4.
Command History Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9000, S6000, S4820T, S4810, and MXL. userrole show role Display information on permissions assigned to a command, including user role and/or permission level. Syntax Parameters show role mode {mode} {command} command Enter the command’s keywords to assign the command to a certain access level. You can enter one or all of the keywords.
Route-map Protocol MAC Exec Config Exec Config Interface Line Router IP Route-map Protocol MAC secadmin sysadmin netoperator testadmin Command Modes Command History Related Commands netadmin Exec Config Interface Line Router IP Route-map Protocol MAC EXEC Privilege Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9000, S6000, S4820T, S4810, MXL. userrole, username userrole Create user roles for the role-based security model.
inherited by security administrator can only modify permissions for commands they already have access to. • Make sure you select the correct role you want to inherit. NOTE: If you inherit a user role, you cannot modify or delete the inheritance. If you want to change or remove the inheritance, delete the user role and create it again. If the user role is in use, you cannot delete the user role.
52 Service Provider Bridging Service provider bridging is composed of virtual local area network (VLAN) Stacking, Layer 2 Protocol Tunneling, and Provider Backbone Bridging as described in the Dell Networking OS Configuration Guide Service Provider Bridging chapter. This chapter includes command line information (CLI) for the Dell Networking operating software Layer 2 Protocol Tunneling (L2PT). L2PT enables protocols to tunnel through an 802.1q tunnel. Dell Networking OS supports L2PT on Dell Networking OS.
• For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. in | out | both Enter the keyword in, out, or both to debug incoming interfaces, outgoing interfaces, or both incoming and outgoing interfaces. vlan vlan-id Enter the keyword vlan then the VLAN ID. The range is from 1 to 4094. count value Enter the keyword count then the number of debug outputs. The range is from 1 to 100. Defaults Debug disabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guid. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.5.1.1 Added support for 802.1X, E-LMI, GMRP, GVRP, LLDP, LACP, MMRP, MVRP, and OAM 802.
Version Description 7.4.1.0 Introduced Usage Information When you enable VLAN-Stacking, no protocol packets are tunneled. Related Command show protocol-tunnel — displays tunneling information for all VLANs. protocol-tunnel enable Enable protocol tunneling globally on the system. Syntax protocol-tunnel enable To disable protocol tunneling, use the no protocol-tunnel enable command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series, E-Series and E-Series ExaScale. 7.4.1.
53 sFlow The Dell Networking operating software (OS) supports sFlow commands on Dell Networking OS. Dell Networking operating software sFlow monitoring system includes an sFlow Agent and an sFlow Collector. • The sFlow Agent combines the flow samples and interface counters into sFlow datagrams and forwards them to the sFlow Collector. • The sFlow Collector analyses the sFlow Datagrams received from the different devices and produces a network-wide view of traffic flows.
To delete a configured collector, use the no sflow collector {ip-address | ipv6-address} agent-addr {ipv4-address | ipv6-address} [number [max-datagram-size number]] | [max-datagram-size number] [vrf management] command. Parameters sflow collector ipaddress | ipv6address Enter the IP address of the collector in dotted decimal format for IPv4 or x:x:x:x::x format for IPv6.
Usage Information Version Description 6.2.1.1 Introduced on the E-Series. You can configure up to two sFlow collectors (IPv4 or IPv6). If two collectors are configured, traffic samples are sent to both. The sFlow agent address is carried in a field in SFlow packets and is used by the collector to identify the sFlow agent. In sFlow, the agent address is a single invariant IPv4 or IPv6 address used to identify the agent to the collector.
Version Description 7.6.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information sFlow is disabled by default. In addition to this command, sFlow needs to be enable on individual interfaces where sFlow sampling is desired. Related Commands sflow enable (Interface) — enables sFlow on interfaces. sflow ingress-enable Enable sFlow ingress on interfaces. Syntax sflow ingress-enable To disable sFlow, use the no sflow ingress enable command. Defaults Disabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S Series and Z Series switches. Dell(conf)#sflow max-header-size extended sflow polling-interval (Global) Set the sFlow polling interval at a global level. Syntax sflow polling-interval interval value To return to the default, use the no sflow polling-interval interval command. Parameters interval value Enter the interval value in seconds. The range is from 15 to 86400 seconds. The default is 20 seconds.
sflow polling-interval (Interface) Set the sFlow polling interval at an interface (overrides the global-level setting.) Syntax sflow polling-interval interval value To return to the default, use the no sflow polling-interval interval command. Parameters interval value Enter the interval value in seconds. The range is from 15 to 86400 seconds. The default is the global counter polling interval. Defaults The same value as the current global default counter polling interval.
Defaults 32768 packets Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.
54 Simple Network Management Protocol (SNMP) and Syslog This chapter contains commands to configure and monitor the simple network management protocol (SNMP) v1/v2/v3 and Syslog. Both features are supported on Dell Networking OS. The chapter contains the following sections: • SNMP Commands • Syslog Commands SNMP Commands The following SNMP commands are available in the Dell Networking OS.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. Example Dell#show snmp engineID Local SNMP engineID: 0000178B02000001E80214A8 Remote Engine ID IP-addr Port 80001F88043132333435 172.31.1.3 5009 80001F88043938373635 172.31.1.
Example Related Commands Dell#show snmp group groupname: v1v2creadg readview : v1v2cdefault notifyview: v1v2cdefault row status: active Dell# security model: v1 writeview: no write view specified context: no context specified snmp-server group — configures an SNMP server group. show snmp user Display the information configured on each SNMP user name. Syntax Command Modes Command History show snmp user • EXEC • EXEC Privilege This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
ipv6 access-listname (Optional) Enter the keyword ipv6 then an IPv6 ACL name (a string up to 16 characters long). security-name name (Optional) Enter the keywords security-name then the security name as defined by the community MIB. access-list-name (Optional) Enter a standard IPv4 access list name (a string up to 16 characters long). Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
Example Dell#config Dell(conf)# snmp-server community public ro Dell(conf)# snmp-server community guest ro security-name guestuser Dell(conf)# Example Dell(conf)# ip access-list standard snmp-ro-acl Dell(config-std-nacl)#seq 5 permit host 10.10.10.224 Dell(config-std-nacl)#seq 10 deny any count ! Dell(conf)#snmp-server community guest ro snmp-ro-acl Dell(conf)# Related Commands ip access-list standard — names (or selects) a standard access list to filter based on IP address.
snmp-server enable traps Enable SNMP traps. Syntax snmp-server enable traps [notification-type] [notification-option] To disable traps, use the no snmp-server enable traps [notification-type] [notification-option] command. Parameters notification-type notification-option Enter the type of notification from the following list: • bgp — Notification of changes in the BGP process. • config — Notification of changes to the startup or running configuration. • ecfm — Notification of changes to ECFM.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Added the following two SNMP notification options: syslog-reachable and syslog-unreachable. 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Added support for copy-config and ECMP traps. 8.3.19.0 Introduced on the S4820T. 8.3.11.
remote ip-address Enter the keyword remote followed by the IP address that identifies the copy of the SNMP on the remote device. vrf vrf-name Enter the keyword vrf followed by the name of the VRF that is used to reach the device. NOTE: Use this attribute to specify the VRF that is used by the SNMP engine to reach the device. If no VRF is specified, then the default VRF is used.
snmp-server group Configure a new SNMP group or a table that maps SNMP users to SNMP views.
Defaults As above. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.
NOTE: The :: notation specifies successive hexadecimal fields of zero. vrf vrf-name Enter the keyword vrf and then the name of the VRF that the SNMP server uses to connect to the host. NOTE: You can use this attribute to inform the SNMP engine about the vrf instance to be used to reach the corresponding remote host to send Trap or Inform message. If no VRF is specified, then the default VRF is used. traps (OPTIONAL) Enter the keyword traps to send trap notifications to the specified host.
• lacp — Enable LACP state change traps. • isis — Enable ISIS adjacency change traps • pfc — Enable pfc traps • snmp — Enable SNMP trap • stp — Enable 802.1d state change traps • vlt — Enable VLT traps • vrrp — Enable VRRP state change traps • xstp — Enable 802.1s, 802.1w, and PVST+ state change traps The default is all trap types are sent to host. Defaults As above. Command Modes CONFIGURATION Command History This guide is platform-specific.
The snmp-server host command is used with the snmp-server enable command. Use the snmpserver enable command to specify which SNMP notifications are sent globally. For a host to receive most notifications, at least one snmp-server enable command and the snmp-server host command for that host must be enabled.
Version Description E-Series legacy command snmp-server packetsize Set the largest SNMP packet size permitted. Wen the SNMP server is receiving a request or generating a reply, use the snmpserver packetsize global configuration command. Syntax Parameters snmp-server packetsize byte-count byte-count Enter one of the following values 8, 16, 24 or 32. Packet sizes are 8000 bytes, 16000 bytes, 32000 bytes, and 64000 bytes.
• For a port channel interface, enter the keywords port-channel then a number. • For a Null interface, enter the keyword null then the Null interface number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults The IP address assigned to the management interface is the default. Command Modes CONFIGURATION Command History This guide is platform-specific.
group_name Enter a text string (up to 20 characters long) as the name of the group. The following groups are created for mapping to read/write community/security-names (defaults): • v1v2creadu — maps to a community with ro permissions. • 1v2cwriteu — maps to a community rw permissions. remote ip-address Enter the keywords udp-port then the user datagram protocol (UDP) port number on the remote device. The range is from 0 to 65535. The default is 162.
ipv6 access-listname (Optional) Enter the keyword ipv6 then the IPv6 access list name (a string up to 16 characters long). access-list-name ipv6 access-listname (Optional) Enter both an IPv4 and IPv6 access list name. Defaults As above. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Dell#conf Dell(conf)# snmp-server user n3user ngroup remote 172.31.1.3 udp-port 5009 3 auth md5 authpasswd Related Commands show snmp user — displays the information configured on each SNMP user name. snmp-server user (for AES128-CFB Encryption) Specify that AES128-CFB encryption algorithm needs to be used for transmission of SNMP information. The Advanced Encryption Standard (AES) Cipher Feedback (CFB) 128-bit encryption algorithm is in compliance with RFC 3826.
command in Global Configuration mode. You can enable or disable FIPS mode only if SNMPv3 users are not previously set up. Otherwise, you must remove the previously configured users before you change the FIPS mode. Example Dell# snmp-server user privuser v3group v3 encrypted auth md5 9fc53d9d908118b2804fe80e3ba8763d priv aes128 d0452401a8c3ce42804fe80e3ba8763d Related Commands show snmp user — Displays the information configured on each SNMP user name.
Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information If the interface is expected to flap during normal usage, you could disable this command. Syslog Commands The following commands allow you to configure logging functions on all Dell Networking switches. clear logging Clear the messages in the logging buffer.
clear logging auditlog Clears audit log. Syntax clear logging auditlog Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL.
default logging console Return the default settings for messages logged to the console. Syntax default logging console Defaults level = 7 or debugging Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Version Description 7.5.1.0 Introduced on the C-Series. E-Series legacy command Related Commands logging monitor — sets the logging monitor parameters. terminal monitor — sends system messages to the terminal/monitor. default logging trap Return to the default settings for logging messages to the Syslog servers. Syntax default logging trap Defaults level = 6 or informational Command Modes CONFIGURATION Command History This guide is platform-specific.
NOTE: The :: notation specifies successive hexadecimal fields of zeros. hostname Enter the name of a host already configured and recognized by the switch. udp Enter the keyword udp to enable transmission of log message over UDP followed by port number. The default port is 514 tcp Enter the keyword tcp to enable transmission of log message over TCP followed by port number. vrf vrf-name (Optional) Enter the keyword vrf and then the name of the VRF to enable the logging process in VRF mode.
logging buffered Enable logging and specify which messages are logged to an internal buffer. By default, all messages are logged to the internal buffer. Syntax logging buffered [level] [size] To return to the default values, use the default logging buffered command. To disable logging stored to an internal buffer, use the no logging buffered command.
logging extended Logs security and audit events to a system log server. Syntax logging extended Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.
• mail (mail system) • news (USENET news) • sys9 (system use) • sys10 (system use) • sys11 (system use) • sys12 (system use) • sys13 (system use) • sys14 (system use) • syslog (Syslog process) • user (user process) • uucp (Unix to Unix copy process) The default is local7. Defaults local7 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters level Indicate a value from 0 to 7 or enter one of the following equivalent words: emergencies, alerts, critical, errors, warnings, notifications, informational, or debugging. The default is 4 or warnings. Defaults warnings or 4 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information When the number of messages reach the limit you set with the logging history size command, older messages are deleted as newer ones are added to the table.
Version Description 7.5.1.0 Introduced on the C-Series. E-Series legacy command Related Commands default logging monitor — returns the logging monitor parameters to the default setting. logging on Specify that debug or error messages are asynchronously logged to multiple destinations, such as the logging buffer, Syslog server, or terminal lines. Syntax logging on To disable logging to logging buffer, Syslog server and terminal lines, use the no logging on command. Defaults Enabled.
logging source-interface Specify that the IP address of an interface is the source IP address of Syslog packets sent to the Syslog server. Syntax logging source-interface interface To disable this command and return to the default setting, use the no logging source-interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.
Usage Information Syslog messages contain the IP address of the interface used to egress the router. By configuring the logging source-interface command, the Syslog packets contain the IP address of the interface configured. Related Commands logging — enables logging to the Syslog server. logging synchronous Synchronize unsolicited messages and Dell Networking OS output.
If the message queue limit is reached on a terminal line and messages are discarded, a system message appears on that terminal line. Messages may continue to appear on other terminal lines. Related Commands logging on — enables logging. logging trap Specify which messages are logged to the Syslog server based the message severity. Syntax logging trap [level] To return to the default values, use the default logging trap command. To disable logging, use the no logging trap command.
logging version Displays syslog messages in a RFC 3164 or RFC 5424 format. Syntax logging version {0|1} Defaults 0 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
%RPM:0:0 %CHMGR-2-LINECARDDOWN - Line card 3 down - IPC timeout Dell# show logging auditlog Displays an audit log. Syntax show logging auditlog Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. This command displays internal software driver information, which may be useful during troubleshooting switch initialization errors, such as a downed Port-Pipe. terminal monitor Configure the Dell Networking OS to display messages on the monitor/terminal.
55 SNMP Traps This chapter lists the traps sent by the Dell Networking operating software. Each trap is listed by the fields Message ID, Trap Type, and Trap Option. Message ID Trap Type Trap Option COLD_START SNMP COLDSTART WARM_START SNMP WARMSTART COPY_CONFIG_COMPLETE SNMP NONE SNMP LINKDOWN SNMP LINKUP SNMP AUTH EGP_NEIGHBOR_LOSS SNMP NONE OSTATE_DOWN SNMP LINKDOWN SNMP LINKUP SNMP NONE SNMP NONE SNMP NONE SNMP NONE %SNMP-5-SNMP_COLD_START: SNMP COLD_START trap sent.
Message ID Trap Type Trap Option SNMP NONE SNMP NONE SNMP NONE NONE NONE ENVMON NONE ENVMON NONE ENVMON NONE CHM_CARD_PROBLEM ENVMON NONE CHM_ALARM_CUTOFF ENVMON NONE CHM_SFM_UP ENVMON NONE CHM_SFM_DOWN ENVMON NONE CHM_RPM_UP ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE %RPM0-P:CP %SNMP-4-RMON_HC_FALLING_THRESHOLD: RMON highcapacity falling threshold alarm from SNMP OID BER_ERR %IFMGR-5-BER_ERR: High Ber detected on interface : %s BER_ERR_CLR %IFMGR-5-BER_ERR_C
Message ID Trap Type Trap Option CHM_SFM_REMOVE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON TEMP ENVMON TEMP ENVMON TEMP ENVMON TEMP ENVMON FAN %TSM-5-SFM_REMOVE: Removed SFM 1 CHM_MAJ_SFM_DOWN %CHMGR-0-MAJOR_SFM: Major alarm: Switch fabric down CHM_MAJ_SFM_DOWN_CLR %CHMGR-5-MAJOR_SFM_CLR: Major alarm cleared: Switch fabric up CHM_MIN_SFM_DOWN %CHMGR-2-MINOR_SFM: MIn
Message ID Trap Type Trap Option ENVMON FAN ENVMON FAN ENVMON FAN ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE For E1200: %CHMGR-2-FAN_TRAY_BAD: Major alarm: fan tray %d is missing or down %CHMGR-2-ALL_FAN_BAD: Major alarm: all fans in fan tray %d are down.
Message ID Trap Type Trap Option ENVMON NONE ENVMON NONE ENVMON NONE PROTO NONE PROTO NONE PROTO NONE PROTO NONE PROTO NONE %MACMGR-5-DETECT_STN_MOVE: Station Move threshold exceeded for Mac %s in vlan %d PORT_TEMP_MAJOR %CHMGR-1-PORT_TEMP_MAJOR: Major Alarm Interface %s shut due to high temperature PORT_TEMP_MINOR %CHMGR-1-PORT_TEMP_MINOR: Minor Alarm Interface %s temperature exceeds threshold PORT_TEMP_MAJOR_CLR %CHMGR-1-PORT_TEMP_MAJOR_CLR: Major Alarm cleared for Interface %s port tem
56 Stacking All commands in this chapter are specific to the Dell Networking operating software. You can use the commands to pre-configure a switch, so that the configuration settings are invoked when the switch is attached to other S-Series units. For information about using the S-Series stacking feature, refer to the “Stacking S-Series Switches” chapter in the Dell Networking OS Configuration Guide. CAUTION: You cannot enable stacking simultaneously with virtual link trunking (VLT).
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Added the members option. Usage Information Enabling this command keeps the failed switch in the Failed state. The switch does not reboot until it is manually rebooted. When enabled, it is not displayed in the running-config.
Protocols lacp Enter the LACP protocol xstp Enter one of the following protocols: STP, RSTP, MSTP, PVST. Defaults Not enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000. 8.3.19.0 Introduced on the S4820T.
Usage Information Resetting the management unit is not allowed, and an error message displays if you try to do so. Resetting is a soft reboot, including flushing the forwarding tables. Starting with Dell Networking OS version 7.8.1.0, you can run this command directly on the stack standby unit (standby master) to reset the standby. You cannot reset any other unit from the standby unit.
Example • grep — show only text that matches a pattern. • no-more — do not paginate the output. • save — save the output to a file.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
Interface Link Speed Admin Link (Gb/s) Status Status ---------------------------------------0/49 12 up up 0/50 12 up down 0/51 24 up up 1/49 12 up up 1/50 12 up up 2/49 24 up up 2/51 12 up up 2/52 12 up down Dell# Example (Topology) Dell# show system stack-ports topology Topology: Ring Interface Connection ---------------------0/49 1/49 0/50 0/51 2/49 1/49 0/49 1/50 2/51 2/49 0/51 2/51 1/50 2/52 Dell# Related Commands • reset stack-unit – resets the designated stack member.
Related Commands Version Description 9.7(0.0) Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. • reload – reboots Dell Networking OS. stack-unit provision Preconfigure a logical stacking ID of a switch that joins the stack. This is an optional command that is executed on the management unit.
stack-unit stack-group Configure the stacking unit and stacking group by specifying an ID when adding units to a stack to ensure the unit is assigned to the correct group. Syntax stack-unit unit-id stack-group stack-group-id To remove the current stack group configuration, use the no stack-unit unit-id stack-group stack-id command. Parameters unit-id Enter the stack unit ID. stack-group-id Enter the stack group ID. The range is from 0 to 15.
all Enter the keyword all to copy the designated image to all stack members. A Enter the keyword A to upgrade all stacked units in System A ( S4820T only). B Enter the keyword B to upgrade all stacked units in System B ( S4820T only). Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
57 Storm Control The Dell Networking operating software storm control feature allows you to limit or suppress traffic during a traffic storm (Broadcast/Unknown Unicast Rate Limiting or Multicast on the C-Series and S-Series). Storm control is supported on Dell Networking OS. Important Points to Remember • Interface commands can only be applied on physical interfaces (virtual local area networks [VLANs] and link aggregation group [LAG] interfaces are not supported).
• Defaults Command Modes Command History For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 E-Series Only: Added the percentage decimal value option. 6.5.1.0 Introduced on the E-Series. Broadcast storm control is valid on Layer 2/Layer 3 interfaces only. Layer 2 broadcast traffic is treated as unknown-unicast traffic.
storm-control multicast (Configuration) Configure the packets per second (pps) of multicast traffic allowed into the C-Series and S-Series networks only. Syntax storm-control multicast packets_per_second in To disable storm-control for multicast traffic into the network, use the no storm-control multicast packets_per_second in command. Parameters packets_per_secon d in Enter the packets per second of multicast traffic allowed into the network. The range is from 0 to 33554368.
Command Modes INTERFACE (conf-if-interface-slot/port) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Usage Information Version Description 6.5.1.0 Introduced on the E-Series. Unknown Unicast Storm-Control is valid for Layer 2 and Layer 2/Layer 3 interfaces. storm-control unknown-unicast (Interface) Configure percentage of unknown-unicast traffic allowed on an interface (ingress only).
Storm Control Version Description 7.5.1.0 Introduced on the C-Series. 7.4.1.0 E-Series Only: Added the percentage decimal value option. 6.5.1.0 Introduced on the E-Series.
58 Spanning Tree Protocol (STP) The commands in this chapter configure and monitor the IEEE 802.1d spanning tree protocol (STP) and are supported on the Dell Networking switch/routing platform. bridge-priority Set the bridge priority of the switch in an IEEE 802.1D spanning tree. Syntax bridge-priority {priority-value | primary | secondary} To return to the default value, use the no bridge-priority command. Parameters priority-value Enter a number as the bridge priority value.
bpdu-destination-mac-address Use the Provider Bridge Group address in Spanning Tree or GVRP PDUs. Syntax bpdu-destination-mac-address [stp | gvrp] provider-bridge-group Parameters xstp Force STP, RSTP, and MSTP to use the Provider Bridge Group address as the destination MAC address in its BPDUs. gvrp Forces GVRP to use the Provider Bridge GVRP Address as the destination MAC address in its PDUs. Defaults The destination MAC address for BPDUs is the Bridge Group Address.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced protocol spanning-tree — enters SPANNING TREE mode on the switch. disable Disable the spanning tree protocol globally on the switch. Syntax disable To enable Spanning Tree Protocol, use the no disable command. Defaults Enabled (that is, the spanning tree protocol is disabled.) Command Modes SPANNING TREE Command History This guide is platform-specific.
Defaults 15 seconds Command Modes SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. forward-delay — changes the wait time before STP transitions to the Forwarding state. max-age — changes the wait time before STP refreshes protocol configuration information.
protocol spanning-tree To enable and configure the spanning tree group, enter SPANNING TREE mode. Syntax protocol spanning-tree stp-id To disable the Spanning Tree group, use the no protocol spanning-tree stp-id command. Parameters stp-id Enter zero (0). Dell Networking OS supports one spanning tree group, group 0. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Example Field Description “Designated port...” Displays the designated port ID. Dell#show spann 0 Executing IEEE compatible Spanning Tree Protocol Bridge Identifier has priority 32768, Address 0001.e800.0a56 Configured hello time 2, max age 20, forward delay 15 We are the root of the spanning tree Current root has priority 32768 address 0001.e800.
Usage Information Example (Guard) The following describes the show spanning-tree 0 guard command shown in the example. Field Description Interface Name STP interface. Instance STP 0 instance. Sts Port state: root-inconsistent (INCON Root), forwarding (FWD), listening (LIS), blocking (BLK), or shut down (EDS Shut). Guard Type Type of STP guard configured (Root, Loop, or BPDU guard).
Enter the optional keyword shutdown-on-violation to hardware disable an interface when a BPDU is received and the port is disabled. priority priority Enter keyword priority then a number as the priority. The range is from zero (0) to 15. The default is 8. Defaults cost = depends on the interface type; priority = 8 Command Modes INTERFACE Command History This guide is platform-specific.
• If a BPDU is received from a remote device, BPDU guard places the port in an Err-Disabled Blocking state and no traffic is forwarded on the port. • If no BPDU is received from a remote device, loop guard places the port in a Loop-Inconsistent Blocking state and no traffic is forwarded on the port. To display the type of STP guard (Portfast BPDU, root, or loop guard) enabled on a port, enter the show spanning-tree 0 command.
59 System Time and Date The commands in this chapter configure time values on the system, either using the Dell Networking operating software, or the hardware, or using the network time protocol (NTP). With NTP, the switch can act only as a client to an NTP clock host. For more information, refer to the “Network Time Protocol” section of the Management chapter in the Dell Networking OS Configuration Guide.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
start-month Enter the name of one of the 12 months in English. start-time Enter the time in hours:minutes. For the hour variable, use the 24-hour format; example, 17:15 is 5:15 pm. end-week Enter the one of the following as the week that daylight saving ends: • week-number: enter a number from 1 to 4 as the number of the week to end daylight saving time. • first: enter the keyword first to end daylight saving time in the first week of the month.
clock timezone Configure a timezone for the switch. Syntax clock timezone timezone-name offset To delete a timezone configuration, use the no clock timezone command. Parameters timezone-name Enter the name of the timezone. You cannot use spaces. offset Enter one of the following: • a number from 1 to 23 as the number of hours in addition to universal time coordinated (UTC) for the timezone. • a minus sign (-) then a number from 1 to 23 as the number of hours. Defaults Not configured.
Parameters adjust Enter the keyword adjust to display information on NTP clock adjustments. all Enter the keyword all to display information on all NTP transactions. authentication Enter the keyword authentication to display information on NTP authentication transactions. events Enter the keyword events to display information on NTP events. loopfilter Enter the keyword loopfilter to display information on NTP local clock frequency.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. You also must configure an authentication key for NTP traffic using the ntp authentication-key command.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. After configuring the ntp authentication-key command, configure the ntp trusted-key command to complete NTP authentication. Dell Networking OS versions 8.2.1.0 and later use an encryption algorithm to store the authentication key that is different from previous Dell Networking OS versions; beginning in version 8.2.1.
ntp disable Prevent an interface from receiving NTP packets. Syntax ntp disable To re-enable NTP on an interface, use the no ntp disable command. Defaults Disabled (that is, if you configure an NTP host, all interfaces receive NTP packets) Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added support for IPv6 multicast addresses. 8.3.7.0 Introduced on the S4810.
Parameters vrf vrf-name (Optional) Enter the keyword vrf and then the name of the VRF to configure a NTP time-serving host corresponding to that VRF. ipv4-address | ipv6address Enter an IPv4 address (A.B.C.D) or IPv6 address (X:X:X:X::X) of NTP server. hostname Enter the hostname of the server. key keyid (OPTIONAL) Enter the keyword key and a number as the NTP peer key. The range is from 1 to 4294967295.
ntp source Specify an interface’s IP address to be included in the NTP packets. Syntax ntp source interface To delete the configuration, use the no ntp source command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. Example Dell#show clock 11:05:56.949 UTC Thu Oct 25 2001 Dell# Example (Detail) Dell#show clock detail 12:18:10.
Field Description (none) One or more of the following symbols could be displayed: • * means synchronized to this peer. • # means almost synchronized to this peer. • + means the peer was selected for possible synchronization. • - means the peer is a candidate for selection. • ~ means the peer is statically configured. remote Displays the remote IP address of the NTP peer. ref clock Displays the IP address of the remote peer’s reference clock.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Added support for VRF. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added IPv6 support. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. show ntp status Display the current NTP status. Syntax show ntp status Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Field Description “frequency is...” Displays the frequency (in ppm), stability (in ppm) and precision (in Hertz) of the clock in this system. “reference time is...” Displays the reference time stamp. “clock offset is...” Displays the system offset to the synchronized peer and the time delay on the path to the NTP root clock. “root dispersion is...” Displays the root and path dispersion. “peer mode is...” State what NTP mode the switch is. This should be Client mode.
60 u-Boot All commands in this chapter are in u-Boot and are supported on the Dell Networking S4810 and 4820T platforms only. To access this mode, press any key when the following line appears on the console during a system boot. Hit any key to stop autoboot: Enter u-Boot immediately, as the => prompt indicates. NOTE: This chapter describes only a few commands available in u-Boot.
+$filesize; cmp.b $loadaddr 0xfff80000 $filesize ethact=eTSEC1 ethaddr=00:01:E8:82:09:B2 serverip=10.11.9.4 primary_boot=f10boot tftp://10.11.9.2/si-S4810-40g secondary_boot=f10boot flash0 default_boot=f10boot tftp://192.168.128.1/FTOS-SC-1.2.0.0E3.bin gatewayip=10.11.192.254 ipaddr=10.11.198.114 netmask=255.255.0.
save Save configurations created in uBoot. Syntax save Command Modes uBoot Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version 8.3.19.0 Introduced on the S4820T. Version 8.3.7.0 Introduced on the S4810.
Command Modes uBoot Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version 8.3.19.0 Introduced on the S4820T. Version 8.3.7.0 Introduced on the S4810.
61 Tunneling Tunneling is supported on Dell Networking OS. ip unnumbered Configure a tunnel interface to operate without a unique IPv4 address and select the interface from which the tunnel borrows its address. Syntax ip unnumbered {interface-type slot/port} To set the tunnel back to default logical address use the no ip unnumbered command. If the tunnel was previously operational, the tunnel interface is operationally down unless you also configure the tunnel IPv6 address.
ipv6 unnumbered Configure a tunnel interface to operate without a unique IPv6 address and select the interface from which the tunnel borrows its address. Syntax ipv6 unnumbered {interface-type interface-number} To set the tunnel back to default logical address use the no ipv6 unnumbered command. If the tunnel was previously operational, the tunnel interface is operationally down unless you also configure the tunnel IPv4 address. Parameters interface-type interface-number Defaults None.
mask (OPTIONAL) Enter a network mask in /prefix format (/x) or A.B.C.D to match a range of remote addresses. The default mask is /32 for IPv4 addresses and /128 for IPv6 addresses, which match only the specified address. Defaults If you do not configure tunnel allow remote , all traffic which is destined to tunnel source address is decapsulated. Command Modes INTERFACE TUNNEL Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.
To establish a logical tunnel to the particular destination address, use the destination address of the outer tunnel header. If you configure a tunnel interface or source address, the tunnel destination must be compatible. tunnel dscp Configure the method to set the DSCP in the outer tunnel header. C9000 Series Syntax tunnel dscp {mapped | value} To use the default tunnel mapping behavior, use the no tunnel dscp value command.
Parameters value Enter a value to set the IPv6 flow label value in the tunnel header. The range is from 0 to 1048575. The default value is 0. Defaults 0 (Mapped original packet flow-label value to tunnel header flow-label value) Command Modes INTERFACE TUNNEL (conf-if-tu) Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.3(0.0) Introduced on the S6000, S4810, S4820T, Z9000.
To disable the tunnel keepalive probes use the no tunnel keepalive command. Parameters ip-address ipv6 address Enter the IPv4 or IPv6 address of the peer to which the keepalive probes will be sent. interval seconds Enter the keyword interval then the interval time, in seconds, after which the restart process to keepalive probe packets. The range is from 5 to 255. The default is 5. count (OPTIONAL) Enter the keyword count to count packets processed by the filter. The range is from 3 to 10.
Parameters ipip Enable tunnel in RFC 2003 mode and encapsulate IPv4 and/or IPv6 datagrams inside an IPv4 tunnel. ipv6 Enable tunnel in RFC 2473 mode and encapsulate IPv4 and/or IPv6 datagrams inside an IPv6 tunnel. ipv6ip Enable tunnel in RFC 4213 mode and encapsulate IPv6 datagrams inside an IPv4 tunnel. decapsulate-any (Optional) Enable tunnel in multipoint receive-only mode. Defaults There is no default tunnel mode.
• anylocal For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Enter the anylocal command to allow the multipoint receive-only tunnel to decapsulate tunnel packets destined to any local ip address. Defaults none Command Modes INTERFACE TUNNEL (conf-if-tu) Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.4(0.0) Added the tunnel source anylocal command. 9.3(0.
62 Uplink Failure Detection (UFD) Uplink failure detection (UFD) provides detection of the loss of upstream connectivity and, if you use this with NIC teaming, automatic recovery from a failed link. clear ufd-disable Re-enable one or more downstream interfaces on the switch/router that are in a UFD-Disabled Error state so that an interface can send and receive traffic.
• uplink-state-group — creates an uplink-state group and enables the tracking of upstream links. debug uplink-state-group Enable debug messages for events related to a specified uplink-state group or all groups. S4820T Syntax debug uplink-state-group [group-id] To turn off debugging event messages, enter the no debug uplink-state-group [group-id] command. Parameters group-id Enables debugging on the specified uplink-state group. The valid group-id values are from 1 to 16.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.2.3 Introduced on the S-Series S50.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.2.3 Introduced on the S-Series S50. You can assign physical port or port-channel interfaces to an uplink-state group. You can assign an interface to only one uplink-state group. Configure each interface assigned to an uplinkstate group as either an upstream or downstream interface, but not both. You can assign individual member ports of a port channel to the group.
downstream disable links Configure the number of downstream links in the uplink-state group that are disabled if one upstream link in an uplink-state group goes down. Syntax downstream disable links {number |all} To revert to the default setting, use the no downstream disable links command. Parameters number Enter the number of downstream links to be brought down by UFD. The range is from 1 to 1024. all Brings down all downstream links in the group.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T 8.3.12.0 Introduced on the S4810. 8.4.2.
! uplink state track 2 downstream TenGigabitEthernet 1/1,3,5,7-10 upstream FortygigabitEthernet 1/31,42 Related Commands • show uplink-state-group — displays the status information on a specified uplink-state group or all groups. • uplink-state-group — creates an uplink-state group and enables the tracking of upstream links. show uplink-state-group Display status information on a specified uplink-state group or all groups.
Upstream Interfaces : Downstream Interfaces : Uplink State Group : 3 Status: Enabled, Up Upstream Interfaces : Te 1/25(Up) Te 1/28(Up) Downstream Interfaces : Te 5/1(Up) Te 5/1(Up) Te 5/3(Up) Te 5/5(Up) Te 5/6(Up) Uplink State Group : 5 Status: Enabled, Down Upstream Interfaces : Te 1/1(Dwn) Te 1/3(Dwn) Te 1/5(Dwn) Downstream Interfaces : Te 5/2(Dis) Te 5/4(Dis) Te 5/11(Dis) Te 5/12(Dis) Te 5/13(Dis) Te 5/14(Dis) Te 5/15(Dis) Uplink State Group : 6 Status: Enabled, Up Upstream Interfaces : Downstream Interf
Usage Information After you enter the command, to assign upstream and downstream interfaces to the group, enter UplinkState-Group Configuration mode. An uplink-state group is considered to be operationally up if at least one upstream interface in the group is in the Link-Up state. An uplink-state group is considered to be operationally down if no upstream interfaces in the group are in the Link-Up state. No uplink-state tracking is performed when a group is disabled or in an operationally down state.
Usage Information Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.4.2.3 Introduced on the S-Series S50. You can assign physical port or port-channel interfaces to an uplink-state group. You can assign an interface to only one uplink-state group.
63 VLAN Stacking With the virtual local area network (VLAN)-stacking feature (also called stackable VLANs and QinQ), you can “stack” VLANs into one tunnel and switch them through the network transparently. The Dell Networking operating software supports this feature on Dell Networking OS. For more information about basic VLAN commands, refer to the Virtual LAN (VLAN) Commands section in the Layer 2 chapter.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the C-Series and S-Series. dei honor Honor the incoming DEI value by mapping it to an Dell Networking OS drop precedence. Enter the command once for 0 and once for 1. Syntax Parameters dei honor {0 | 1} {green | red | yellow} 0|1 Enter the bit value you want to map to a color.
dei mark Set the DEI value on egress according to the color currently assigned to the packet. S4820T Syntax dei mark {green | yellow} {0 | 1} Parameters 0|1 Enter the bit value you want to map to a color. green | red | yellow Choose a color: • Green: High priority packets that are the least preferred to be dropped. • Yellow: Lower priority packets that are treated as best-effort. Defaults All the packets on egress are marked with DEI 0.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Defaults Not configured. Command Modes CONF-IF-VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.
Usage Information WARNING: The following message displays to confirm the command: All non-default configurations on the related member ports ports () will be removed. Do you want to continue (y/n)? If you enter “y”, all non-default configurations on any member ports of the current stack group is removed when the unit is rebooted. vlan-stack access Specify a Layer 2 port or port channel as an access port to the stackable VLAN network.
To disable the Stackable VLAN feature on a VLAN, use the no vlan-stack compatible command. Defaults Not configured. Command Modes CONF-IF-VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
vlan-stack dot1p-mapping Map C-Tag dot1p values to a S-Tag dot1p value. You can separate the C-Tag values by commas and dashed ranges are permitted. Dynamic mode CoS overrides any Layer 2 QoS configuration in case of conflicts. Syntax vlan-stack dot1p-mapping c-tag-dot1p values sp-tag-dot1p value Parameters c-tag-dot1p value Enter the keyword c-tag-dot1p then the customer dot1p value that is mapped to a service provider do1p value. The range is from 0 to 7.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. C-Series and S-Series accept both bytes of the 2-byte S-Tag TPID. 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series and S-Series.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. C-Series and S-Series accept both bytes of the 2-byte S-Tag TPID. 7.8.1.0 Functionality augmented for C-Series and S-Series to enable multi-purpose use of the port. 7.7.1.0 Functionality augmented for E-Series to enable multi-purpose use of the port. 7.6.1.
! interface Vlan 20 no ip address tagged TenGigabitEthernet 1/42 shutdown Dell(conf-if-vl-20)#do show vlan Codes: * - Default VLAN, G - GVRP VLANs Q: U - Untagged, T - Tagged x - Dot1x untagged, X - Dot1x tagged G - GVRP tagged, M - Vlan-stack NUM Status Description * 1 Inactive 20 Active 100 Active Dell(conf-if-vl-20)# Example 2 Q Ports T Te 1/42 M Te 1/42 Dell(config)#vlan-stack protocol-type 88A8 Dell(config)#interface TenGigabitethernet 3/10 Dell(conf-if-te-3/10)#no shutdown Dell(conf-if-te-3/10)#swit
64 Virtual Link Trunking (VLT) Virtual link trunking (VLT) allows physical links between two chassis to appear as a single virtual link to the network core. VLT eliminates the requirement for Spanning Tree protocols by allowing link aggregation group (LAG) terminations on two separate distribution or core switches, and by supporting a loop-free topology.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.2(0.2) Added support for IPv6. 9.0.2.
Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. Example VLT ARP Statistics ---------------ARP Tunnel Pkts sent:0 ARP Tunnel Pkts Rcvd:0 ARP-sync Pkts Sent:0 ARP-sync Pkts Rcvd:0 ARP Reg Request sent:19 ARP Reg Request rcvd:10 Related Commands show vlt statistics — displays statistics on VLT operations.
Related Commands • after a VLT device is reloaded. • if the Peer VLT device was up at the time the VLTi link failed to the time when it was restored. show vlt statistics — displays statistics on VLT operations. delay-restore abort-threshold Increase the Boot Up timer to some value (>60 seconds). Syntax delay-restore abort-threshold To remove use the no delay-restore abort-threshold command. Defaults 60 seconds Command Modes VLT DOMAIN Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Added port-channel parameter on the S4810. 8.3.8.0 Introduced on the S4810.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. 9.0.2.0 Introduced on the S6000. peer-link port-channel Configure the specified port channel as the chassis interconnect trunk between VLT peers in the domain.
peer-routing Enable L3 VLT peer-routing. This command is applicable for both IPV6/ IPV4. Syntax peer-routing To disable L3 VLT peer-routing, use the no peer-routing command. Defaults Disabled. Command Modes VLT DOMAIN (conf-vlt-domain) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Version Description 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. 9.0.2.0 Introduced on the S6000. When the timer expires, the software checks to see if the VLT peer is now available. If the VLT peer is not available, peer-routing is disabled on that peer. primary-priority Assign the priority for master election among VLT peers.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. Dell_VLTpeer1# show vlt backup-link VLT Backup Link ----------------Destination: Peer HeartBeat status: HeartBeat Timer Interval: HeartBeat Timeout: UDP Port: HeartBeat Messages Sent: HeartBeat Messages Received: 10.11.200.
Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. Usage Information If you do not add a parameter such as arp or mac, the output displays all of the counters.
Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.
(*, 225.1.1.2) Dell# VLAN 15 te 1/5 show vlt mismatch Display mismatches in VLT parameters. Syntax show vlt mismatch Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.
PB for stp Enabled Disabled Vlan-type-config ---------------Codes:: P - Primary, C - Community, I - Isolated, N - Normal vlan, M Vlan-stack Vlan-ID ------- Local ----- 100 Peer ---- N M Port-type-config ---------------Codes:: p - PVLAN Promiscuous port, h - PVLAN Host port, t - PVLAN Trunk port, mt - Vlan-stack trunk port, mu - Vlan-stack access port, n Normal port Vlt Lag ------128 Local ----mt Peer ---mu Vlan-stack protocol-type -----------------------Local ----0x4100 Peer ---0x8100 VLT-VLAN
Example Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810.
Related Commands Example Version Description 9.2(0.2) Added parameters multicast and ndp 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Added support in the output for ARP, MAC, and IGMP snooping. 8.3.8.0 Introduced on the S4810. clear vlt statistics — clears the statistics on VLT operations. NOTE: The following example shows the statistics for all of the VLT parameters.
NDP NA VLT Tunnel Pkts Rcvd:46 NDP NA Non-VLT Tunnel Pkts sent:0 NDP NA Non-VLT Tunnel Pkts Rcvd:0 Ndp-sync Pkts Sent:144 Ndp-sync Pkts Rcvd:105 Ndp Reg Request sent:25 Ndp Reg Request rcvd:24 show vlt statistics igmp-snoop Displays the informational packets and IGMP control PDUs that are exchanged between VLT peer nodes. Syntax show vlt statistics igmp-snoop Default Not configured. Command Modes EXEC Command History This guide is platform-specific.
Parameters mac-address Enter the system MAC address for the VLT domain. Defaults Not configured. Command Modes VLT DOMAIN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator.
Usage Information Version Description 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. When you create a VLT domain on a switch, Dell Networking OS automatically assigns a unique unit ID (0 or 1) to each peer switch. The unit IDs are used for internal system operations.
Related Commands show vlt — uses the show vlt brief command to display the delay-restore value. vlt-peer-lag port-channel Associate the port channel to the corresponding port channel in the VLT peer for the VLT connection to an attached device. Syntax Parameters vlt-peer-lag port-channel id-number id-number Enter the respective vlt port-channel number of the peer device. The range is from 1 to 128. Defaults Not configured.
Usage Information If you add an ICL or VLTi link as a member of a primary VLAN, the ICL becomes a part of the primary VLAN and its associated secondary VLANs, similar to the behavior for normal trunk ports. VLAN symmetry is not validated if you associate an ICL to a PVLAN. Similarly, if you dissociate an ICL from a PVLAN, although the PVLAN symmetry exists, ICL is removed from that PVLAN in such a case. The ICL Status field denotes the type of the VLAN port of the VLTi link configured in a PVLAN.
65 VLT Proxy Gateway The Virtual link trucking (VLT) proxy gateway feature allows a VLT domain to locally terminate and route L3 packets that are destined to a Layer 3 (L3) end point in another VLT domain. Enable the VLT proxy gateway using the link layer discover protocol (LLDP) method or the static configuration. For more information, refer to Dell Networking OS Command Line Reference Guide. proxy-gateway lldp Enables the proxy-gateway feature using LLDP protocol.
Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, Z9000. Usage Information When proxy-gateway static configuration is added, the setting is saved in the Layer 2 module. When you remove the static proxy gateway configuration, each proxy-gateway static mac configured is deleted from the Layer 2 module.
peer-domain-link port-channel exclude-vlan Configure the VLT port channel, which is connected to remote VLT domain for Proxy Gateway and configure the VLANs that needs to be excluded from VLT Proxy Gateway. S4820T Syntax Parameters [no] peer-domain-link port-channel interface-identifier exclude-vlan vlanrange port-channel Configure the proxy-gateway interface port-channel. Port channel range is from 1 to 128. vlan-range Enter the VLAN IDs in which proxy gateway is not needed.
Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Removed the default value on the S-Series and Z-Series. 9.4(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL Switch. Usage Information When a VLT peer goes down, the local VLT node must stop sending its peer’s MAC address. If this timeout is configured, the local VLT node will send its peer's MAC address, till the timer expires. By default this timer value is infinity.
static Command Modes Display details about the static VLT proxy gateway configuration EXEC EXEC Privilege Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000.
66 Virtual Routing and Forwarding (VRF) Virtual Routing and Forwarding (VRF) allows multiple instances of a routing table to co-exist on the same router at the same time. ip vrf Creates a customer VRF. Syntax ip vrf {vrf-name | management} [vrf_id] To delete a customer VRF, use the no ip vrf {vrf-name | management} [vrf_id] command. Parameters vrf-name Enter the name of the VRF that you want to create. management Use this keyword when you want to create the management VRF.
ip http vrf Configures an HTTP client with a VRF that is used to connect to the HTTP server. S4820T Syntax ip http vrf {management | vrf-name} To undo the HTTP client configuration, use the ip http vrf command. Parameters management Enter the keyword management for configuring the management VRF that uses an HTTP client. vrf-name Enter the name of the VRF for configuring a nondefault that uses an HTTP client.
Usage Information Version Description 9.5(0.0) Introduced on the Z9500. 9.4.(0.0) Introduced on the S-Series. Use this command to specify a descriptive name for a VRF. ip vrf forwarding Enables you to attach an interface to a VRF. Syntax ip vrf forwarding {vrf-name | management} To delete an interface associated with a configured VRF, use the no ip vrf forwarding {vrf-name | management} command. Parameters vrf-name Enter name of the VRF that you want to associate the interface to.
ip vrf red 4 description "Red Network" Dell(conf-vrf)# Dell(conf-if-te-1/45)#int te 7/46 Dell(conf-if-te-1/46)#no shut Dell(conf-if-te-1/46)#ip vrf forwarding red Dell(conf-if-te-1/46)#ip add 100.1.1.1/24 Dell(conf-if-te-1/46)# Dell(conf-if-te-1/46)# Dell(conf-if-te-1/46)# Dell(conf-if-te-1/46)#show config ! interface TenGigabitEthernet 1/46 ip vrf forwarding red ip address 100.1.1.1/24 no shutdown Dell(conf-if-te-1/46)# ip route-export Enables route leaking between VRFs.
Only Active routes are eligible for leaking. For example, if one VRF has two routes corresponding to BGP and OSPF, in which the BGP route is not active, the OSPF route takes precedence over BGP. Even though the Target VRF has specified filtering options to match BGP, the BGP route is not leaked as that route is not active in the Source VRF. Related Commands ip route-import – imports routes from another VRF.
ipv6 route-export Enables route leaking between VRFs. Exports or shares IPv6 routes corresponding to one VRF with other non-default VRFs. Syntax Parameters Defaults ipv6 route-export tag [route-map-name] route-export Enter the keyword route-export to leak or share routes between VRFs. tag Enter a tag (ASN number) as the export route target to expose routes to other VRFs. This tag acts as an identifier for exported routes.
Parameters route-import Enter the keyword route-import to import IPv6 routes into the VRF. tag Enter a tag (ASN number) to specify an import route target for importing routes from another VRF. To import leaked routes from another VRF, you must use the same ASN number that is specified as the export route target at the source VRF. route-map-name Enter the name of the route-map to filter the imported routes. NOTE: You must use the route-map attribute while importing routes from the global RTM.
Usage Information You can specify the matching criteria only after defining a route-map. Before using this command, you must enter the route map mode using the route-map route-map-name command. The match criteria that you specify is associated with the route-map that you define. The export-target and import-target support only the match protocol and match prefix-list options. Other options that are configured in the route-maps are ignored.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.4.(0.0) Introduced on the S-Series and Z9000. Use this command to associate a management port with a management VRF.
Usage Information If the maximum route limit is not specified for a VRF, then it has unlimited space that extends to the maximum number of entries allowed for the system. This command is not applicable to the default and management VRFs. show ip vrf Displays information corresponding to the VRFs that are configured in the system. Syntax Parameters Command Modes show ip [vrf vrf-name] vrf vrf-name Enter the keyword vrf and then the name of the VRF to display information corresponding to that VRF..
test1 1 Te 0/14,16-17 show run vrf Displays configuration information corresponding to all the VRFs in the system. Syntax show run vrf vrf-name Parameters Command Modes Command History vrf vrf-name • EXEC • EXEC Privilege Enter the keyword vrf and then the name of the VRF.. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
67 Virtual Router Redundancy Protocol (VRRP) Virtual router redundancy protocol (VRRP) is supported by the Dell Networking operating system on Dell Networking OS. IPv4 VRRP Commands The following are IPv4 VRRP commands. advertise-interval Set the time interval between VRRP advertisements. Syntax advertise-interval {seconds | centisecs centisecs } To return to the default settings, use the no advertise-interval command. Parameters seconds Enter a number of seconds. The range is from 1 to 255.
Usage Information Dell Networking recommends keeping the default setting for this command. If you do change the time interval between VRRP advertisements on one router, change it on all routers. authentication-type Enable authentication of VRRP data exchanges. Syntax authentication-type simple [encryption-type] password To delete an authentication type and password, use the no authentication-type command. Parameters simple Enter the keyword simple to specify simple authentication.
Parameters vrrp-id (OPTIONAL) Enter the number of the VRRP group ID. The range is from 1 to 255. ipv6 (OPTIONAL) Enter the keyword ipv6 to clear counters from the IPv6 VRRP group. vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to clear counters that are maintained on the VRRP operations corresponding to that VRF. Command Modes EXEC Privilege Command History This guide is platform-specific.
• For a VLAN interface, enter the keyword vlan then the VLAN ID. The VLAN ID range is from 1 to 4094. vrrp-id (OPTIONAL) Enter a number from 1 to 255 as the VRRP group ID. all Enter the keyword all to enable debugging of all VRRP groups. bfd Enter the keyword bfd to enable debugging of VRRP BFD interactions. database Enter the keyword database to enable debugging of configuration changes. interface Enter the keyword interface to enable debugging of interface state changes..
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. disable Disable a VRRP group. Syntax disable To re-enable a disabled VRRP group, use the no disable command.
To return to the default value, use the no hold-time command. Parameters seconds Enter the number of seconds. The range is from 0 to 65535. The default is zero (0) seconds. centisecs centisecs Enter the keyword centisecs then the number of centisecs in units of 25 centisecs . The range is from 0 to 65525 in units of 25 centisecs. Defaults zero (0) seconds or or (0) centiseconds Command Modes VRRP Command History This guide is platform-specific.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. priority Specify a VRRP priority value for the VRRP group. The VRRP protocol uses this value during the MASTER election process.
If you set the priority command to 255 and the virtual-address is not equal to the interface’s primary IP address, an error message appears. show config View the non-default VRRP configuration. Syntax show config [verbose] Parameters verbose (OPTIONAL) Enter the keyword verbose to view all VRRP group configuration information, including defaults. Command Modes VRRP Command History This guide is platform-specific.
Command Modes Command History • For Port Channel interface types, enter the keywords port-channel then the number. The 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot • For a VLAN interface, enter the keyword vlan then the VLAN ID. The VLAN ID range is from brief (OPTIONAL) Enter the keyword brief to view a table of information on the VRRP groups. ipv6 (OPTIONAL) Enter the keyword ipv6 to view only VRRP IPv6 groups.
Item Description Master addr Displays the IP address of the MASTER router. Virtual addr(s) Displays the virtual IP addresses of the VRRP routers associated with the interface. Example (Brief) Dell>Interface Grp Pri Pre State Master addr Virtual addr(s) Description-----------------------------------------------------------Te 1/37 1 100 Y Master 200.200.200.200 200.200.200.201 Te 1/37 2 100 Y Master 200.200.200.200 200.200.200.202 200.200.200.203 Description Te 1/37 3 100 Y Master 1.1.1.1 1.1.1.
State: Master, Priority: 105, Master: 10.1.1.253 (local) Hold Down: 0 sec, Preempt: TRUE, AdvInt: 1 sec Adv rcvd: 0, Adv sent: 1862, Gratuitous ARP sent: 0 Virtual MAC address: 00:00:5e:00:01:01 Virtual IP address: 10.1.1.252 Authentication: (none) Tracking states for 1 interfaces: Up TenGigabitEthernet 1/17 priority-cost 10 -----------------TenGigabitEthernet 1/4, VRID: 2, Net: 10.1.2.253 State: Master, Priority: 110, Master: 10.1.2.
• priority-cost Defaults priority cost = 10 Command Modes VRRP Command History Usage Information For a VLAN interface, enter the keyword vlan followed by the VLAN ID. The VLAN ID range is from 1 to 4094. (OPTIONAL) Enter a number as the amount to be subtracted from the priority value. The range is 1 to 254. The default is 10. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 7.6.1.0 Introduced on the S-Series (S50 only). 7.5.1.
Usage Information You can use the version both command to migrate from VRRPv2 to VRRPv3. When you set the VRRP protocol version to both, the switch sends only VRRPv3 advertisements but can receive either VRRPv2 or VRRPv3 packets. To migrate an IPv4 VRRP group from VRRPv2 to VRRPv3: 1. Set the switches with the lowest priority to “both”. 2. Set the switch with the highest priority to version to 3. 3. Set all the switches from both to version 3.
Usage Information Version Description 7.4.1.0 Introduced support for telnetting to the VRRP group IP address assigned using this command. 6.2.1.1 Introduced on the E-Series. The VRRP group only becomes active and sends VRRP packets when a virtual IP address is configured. When you delete the virtual address, the VRRP group stops sending VRRP packets. A system message appears after you enter or delete the virtual-address command.
vrrp delay reload Set the delay time for VRRP initialization after a system reboot. Syntax Parameters vrrp delay reload seconds seconds Enter the number of seconds for the delay. The range is from 0 to 900 (0 indicates no delay). Defaults 0 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. 8.4.1.0 Introduced on E-Series ExaScale, C-Series, and S-Series.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. 8.4.1.0 Introduced on E-Series ExaScale, C-Series, and S-Series. Support was added for IPv6 VRRP groups in non-default VRF instances. 8.3.2.0 Introduced on the E-Series TeraScale. If no options are specified, debug is active on all interfaces and all VRRP groups. show vrrp ipv6 View the IPv6 VRRP groups that are active.
Line Beginning with Description GigabitEthernet... Displays the Interface, the VRRP group ID, and the network address. If the interface is no sending VRRP packets, 0.0.0.0 appears as the network address. VRF VRF instance to which the interface (on which the VRRP group is configured) belongs. State: master... Displays the interface’s state: • Na/If (not available). • master (MASTER virtual router). • backup (BACKUP virtual router). the interface’s priority and the IP address of the MASTER.
Virtual IP address: 1::255 fe80::255 vrrp-ipv6-group Assign an interface to a VRRP group. Syntax vrrp-ipv6-group vrid Parameters vrid Enter the virtual-router ID number of the VRRP group. The VRID range is from 1 to 255. Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.