Users Guide
pem Enter the keyword pem to view only information on power entry modules.
Command Modes
• EXEC
• EXEC Privilege
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell Networking OS
Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
9.0.0.0 Introduced on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.3.11.1 Introduced on the Z9000.
7.8.1.0 The output of the show environment fan command for the S-Series is changed to display
fan speeds instead of showing the fan status as up or down.
Usage Information The following example shows the output of the show environment command.
Example (all)
Dell#show environment
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
------------------------------------------------------------------------------------
0 0 up up 6971 up 7072
0 1 up up 6971 up 7021
0 2 up up 7021 up 7021
Speed in RPM
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
0 0 down UNKNOWN down 0
0 1 up AC up 6504
-- Unit Environment Status --
Unit Status Temp Voltage TempStatus
---------------------------------------------------------------------------
* 0 online 36C ok 1
* Management Unit
-- Thermal Sensor Readings (deg C) --
Unit Sensor0 Sensor1 Sensor2 Sensor3 Sensor4 Sensor5 Sensor6
---------------------------------------------------------------------
0 40 36 37 37 31 31 46
Dell#show environment fan
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
------------------------------------------------------------------------------------
0 0 up up 7021 up 7021
128
Control and Monitoring