Users Guide
Defaults none
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell 
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
E-Series legacy 
command
Usage Information The oid-tree variable is a full sub-tree starting from 1.3.6 and cannot specify the name of a sub-tree or a 
MIB. The following Example congures a view named rview that allows access to all objects under 1.3.6.1.
Example
Dell# conf
Dell#(conf) snmp-server view rview 1.3.6.1 included
Related Commands show running-cong snmp — displays the SNMP running conguration.
snmp trap link-status
Enable the interface to send SNMP link traps, which indicate whether the interface is up or down.
Syntax
snmp trap link-status
To disable sending link trap messages, use the no snmp trap link-status command.
Defaults Enabled.
Command Modes INTERFACE
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell 
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-
Mux (PMUX) mode only.
8.3.19.0 Introduced on the S4820T.
Simple Network Management Protocol (SNMP) and Syslog
1435