Users Guide
that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress 
interfaces.
You can activate ow-based monitoring for a monitoring session by entering the ow-based enable 
command in the Monitor Session mode. When you enable this capability, trac with particular ows that are 
traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in 
both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only 
specied trac instead all trac on the interface. This feature is particularly useful when looking for 
malicious trac. It is available for Layer 2 and Layer 3 ingress and egress trac. You may specify trac using 
standard or extended access-lists. This mechanism copies all incoming or outgoing packets on one port and 
forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination 
port is the monitoring port (MG).
seq ether-type (for Extended MAC ACLs)
Congure an egress lter with a specic sequence number that lters trac with specied types of Ethernet packets. This 
command is supported only on 12-port GE line cards with SFP optics. For specications, refer to your line card documentation.
NOTE: Only the options that have been newly introduced in Release 9.3(0.0) and Release 9.4(0.0) are described here. 
For a complete description on all of the keywords and variables that are available with this command, refer the topic of 
this command discussed earlier in this guide.
Syntax
seq sequence-number {deny | permit} ether-type protocol-type-number 
{destination-mac-address mac-address-mask | any} vlan vlan-id {source-mac-
address mac-address-mask | any} [count [byte]] [order] [log [interval 
minutes] [threshold-in-msgs [count]] [monitor]
To remove this lter, use the no seq sequence-number command.
Parameters
log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
threshold-in msgs 
count
(OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to 
indicate the maximum number of ACL logs that can be generated, exceeding which 
the generation of ACL logs is terminated. with the seq, permit, or deny commands. 
You can enter a threshold in the range of 1-100.
interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes 
at which ACL logs must be generated. You can enter an interval in the range of 1-10 
minutes.
monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the trac 
that you want to monitor and the ACL in which you are creating the rule is applied 
to the monitored interface.
Defaults
By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
The default frequency at which ACL logs are generated is 5 minutes. By default, ow-based monitoring is 
not enabled.
Command Modes CONFIGURATION-EXTENDED-ACCESS-LIST
Access Control Lists (ACL)
299