Users Guide
Command History
Version Description
9.7(0.0) Introduced on the S6000-ON.
9.3(0.0) Introduced on the S4810, S6000 platforms.
Usage Information
PFC and ETS settings are not pre-congured on Ethernet ports. You must use the dcb-map command to
congure dierent groups of 802.1p priorities with PFC and ETS settings.
Using the priority-pgid command, you assign each 802.1p priority to one priority group. A priority
group consists of 802.1p priority values that are grouped together for similar bandwidth allocation and
scheduling, and that share latency and loss requirements. All 802.1p priorities mapped to the same queue
must be in the same priority group. For example, the
priority-pgid 0 0 0 1 2 4 4 4 command
creates the following groups of 802.1p priority trac:
• Priority group 0 contains trac with dot1p priorities 0, 1, and 2.
• Priority group 1 contains trac with dot1p priority 3.
• Priority group 2 contains trac with dot1p priority 4.
• Priority group 4 contains trac with dot1p priority 5, 6, and 7.
To remove a priority-pgid conguration from a DCB map, enter the no priority-pgid command.
pfc mode on
Enable the PFC conguration on the port so that the priorities are included in DCBX negotiation with peer PFC devices.
Syntax
pfc mode on
To disable the PFC conguration, use the no pfc mode on command.
Defaults PFC mode is on.
Command Modes DCB MAP
Command History
Version Description
9.7(0.0) Introduced on the S6000-ON.
9.3(0.0) Introduced on the MXL 10/40GbE Switch with the FC Flex IO module.
Usage Information
By applying a DCB input policy with PFC enabled, you enable PFC operation on ingress port trac. To
achieve complete lossless handling of trac, also enable PFC on all DCB egress ports or congure the dot1p
priority-queue assignment of PFC priorities to lossless queues (refer to pfc no-drop queues).
To disable PFC operation on an interface, enter the no pfc mode on command in DCB Input Policy
Conguration mode. PFC is enabled and disabled as global DCB operation is enabled (
dcb-enable) or
disabled (no dcb-enable).
You cannot enable PFC and link-level ow control at the same time on an interface.
498
Data Center Bridging (DCB)