Users Guide
Version Description
9.7(0.0) Introduced the support for bmp-boot on the S-Series and Z-Series switches.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
Usage Information To display these changes in the show bootvar command output, save the running conguration to the 
startup conguration (using the copy command) and reload system.
The keyword bmp-boot is used only when the device boots up from BMP. In case of industrial standard 
upgraded device, the Dell networking OS stores the image partition upgraded from the DHCP oer in bmp-
boot variable.
cd
Change to a dierent working directory.
Syntax
cd directory
Parameters
directory (OPTIONAL) Enter one of the following:
• flash: (internal Flash) or any sub-directory
• nfsmount://<mount-point>/filepath: NFS mounted path
NOTE: While switching to a remote NFS le system, it is mandatory to 
specify the mount-point that indicates the working directory on the 
NFS le system. You cannot enter the root directory of the remote NFS 
le system.
•
usbflash: (internal Flash) or any sub-directory
Command Modes EXEC Privilege
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell 
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Added NFS mount support. Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
File Management
59