Users Guide
AutoNegotiation 
Expansion
ParallelDetectionFault is the handshaking scheme in which the link partner 
continuously transmit an “idle” data packet using the Fast Ethernet MLT-3 
waveform. Equipment that does not support auto-negotiation must be congured 
to exactly match the mode of operation as the link partner or else no link can be 
established.
1000Base-T Control 1000Base-T requires auto-negotiation. The IEEE Ethernet standard does not 
support setting a speed to 1000 Mbps with the speed command without auto-
negotiation. E-Series line cards support both full-duplex and half-duplex 
1000BaseT.
Phy Specic 
Control
Values are:
• 0 - Manual MDI
• 1 - Manual MDIX
• 2 - N/A
• 3 - Auto MDI/MDIX
Phy Specic Status Displays PHY-specic status information. Cable length represents a rough estimate 
in meters:
• 0 - < 50 meters
• 1 - 50 - 80 meters
• 2 - 80 - 110 meters
• 3 - 110 - 140 meters
• 4 - 140 meters
Link Status: Up or Down
Speed:
• Auto
• 1000MB
• 100MB
• 10MB
Example
Dell#show interfaces tengigabitethernet 1/0 phy
Mode Control:
 SpeedSelection: 10b
 AutoNeg: ON
 Loopback: False
 PowerDown: False
 Isolate: False
 DuplexMode: Full
Mode Status:
 AutoNegComplete: False
 RemoteFault: False
 LinkStatus: False
 JabberDetect: False
AutoNegotation Advertise:
 100MegFullDplx: True
 100MegHalfDplx: True
 10MegFullDplx: False
 10MegHalfDplx: True
 Asym Pause: False
 Sym Pause: False
AutoNegotiation Remote Partner's Ability:
 100MegFullDplx: False
 100MegHalfDplx: False
Interfaces