Users Guide

For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the
slot/port information.
interface interface-
type
(OPTIONAL) Instead of entering the keyword interface then the interface type,
slot/port information, as above, you can enter the interface type, then just a slot
number.
vlan vlan-id (OPTIONAL) Enter the keyword vlan then the VLAN ID to display the MAC
address assigned to the VLAN. The range is 1 to 4094.
count (OPTIONAL) Enter the keyword count, then optionally, by an interface or VLAN
ID, to display total or interface-specic static addresses, dynamic addresses, and
MAC addresses in use.
Command Modes
EXEC
EXEC Privilege
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.12.0 Updated the output.
8.5.1.0 Added support for 4-port 40G line cards on ExaScale.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
pre-6.2.1.1 Introduced on the E-Series.
Usage Information The following describes the show mac-address-table command shown in the following example.
Column Heading Description
VlanId Displays the VLAN ID number.
Mac Address Displays the MAC address in nn:nn:nn:nn:nn:nn format.
Type Lists whether the MAC address was manually congured (Static), learned
dynamically (Dynamic), or associated with a specic port (Sticky).
Interface Displays the interface type and slot/port information. The following abbreviations
describe the interface types:
gi — Gigabit Ethernet then a slot/port.
po — Port Channel then a number. The range is from 1 to 255 for TeraScale.
te — 10 Gigabit Ethernet then a slot/port.
Layer 2
933