Deployment Guide
28  Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail 4.5 
S5148F-Leaf1A 
S5148F-Leaf1B 
switchport trunk allowed vlan 1612-
1615 
spanning-tree port type edge 
flowcontrol receive on 
flowcontrol transmit off 
no shutdown 
interface ethernet1/1/18 
description Node2_Port1 
switchport mode trunk 
switchport access vlan 1611 
switchport trunk allowed vlan 1612-
1615 
spanning-tree port type edge 
flowcontrol receive on 
flowcontrol transmit off 
no shutdown 
interface ethernet1/1/19 
description Node3_Port1 
switchport mode trunk 
switchport access vlan 1611 
switchport trunk allowed vlan 1612-
1615 
spanning-tree port type edge 
flowcontrol receive on 
flowcontrol transmit off 
no shutdown 
interface ethernet1/1/20 
description Node4_Port1 
switchport mode trunk 
switchport access vlan 1611 
switchport trunk allowed vlan 1612-
1615 
spanning-tree port type edge 
flowcontrol receive on 
flowcontrol transmit off 
no shutdown 
switchport trunk allowed vlan 1612-
1615 
spanning-tree port type edge 
flowcontrol receive on 
flowcontrol transmit off 
no shutdown 
interface ethernet1/1/18 
description Node2_Port2 
switchport mode trunk 
switchport access vlan 1611 
switchport trunk allowed vlan 1612-
1615 
spanning-tree port type edge 
flowcontrol receive on 
flowcontrol transmit off 
no shutdown 
interface ethernet1/1/19 
description Node3_Port2 
switchport mode trunk 
switchport access vlan 1611 
switchport trunk allowed vlan 1612-
1615 
spanning-tree port type edge 
flowcontrol receive on 
flowcontrol transmit off 
no shutdown 
interface ethernet1/1/20 
description Node4_Port2 
switchport mode trunk 
switchport access vlan 1611 
switchport trunk allowed vlan 1612-
1615 
spanning-tree port type edge 
flowcontrol receive on 
flowcontrol transmit off 
no shutdown 
7.2.4  Configure the switch interconnect 
Create a port channel to use between the two leaf switches, 127 in this example. Use the switchport 
mode trunk command to enable the port channel to carry traffic for multiple VLANs, and allow all VLANs on 
the port channel.  
Use 100GbE interfaces for the port channel, 1/1/53 and 1/1/54 in this example. Add each interface to the port 
channel as LACP active members with the channel-group 127 mode active command. 
When the configuration is complete, exit configuration mode and save the configuration with the end and 
write memory commands. 