Deployment Guide
29  Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail 4.5 
  Configure switch interconnect - dual switch without VLT 
S5148F-Leaf1A 
S5148F-Leaf1B 
interface port-channel 127 
description To_Leaf_1B 
switchport mode trunk 
switchport trunk allowed vlan 1611-
1615 
no shutdown 
interface ethernet1/1/53 
description To_Leaf_1B 
channel-group 127 mode active 
no shutdown 
interface ethernet1/1/54 
description To_Leaf_1B 
channel-group 127 mode active 
no shutdown 
end 
write memory 
interface port-channel 127 
description To_Leaf_1A 
switchport mode trunk 
switchport trunk allowed vlan 1611-
1615 
no shutdown 
interface ethernet1/1/53 
description To_Leaf_1A 
channel-group 127 mode active 
no shutdown 
interface ethernet1/1/54 
description To_Leaf_1A 
channel-group 127 mode active 
no shutdown 
end 
write memory 
7.3  Single switch 
This example uses a four-node VxRail cluster connected to a single switch as shown below. 
25GbE connections
Rack 1
S5148F-ON
1/1/23 21 19 17
VxRail node 1
VxRail node 2
VxRail node 3
VxRail node 4
18 20 22 24
Note: The jump box/DNS server, not 
shown, is connected to ports 1/1/9 
and 1/1/10.
  Four-node cluster connected to a single switch 
The commands in the following sections are run to complete the switch configuration. The port numbers used 
in the configuration commands correspond to those shown in Figure 14. 