Setup Guide

Table 2. Environmental parameters
Parameter Specications
Operating temperature 0°C to 45°C (32°F to 113°F) continuously
-5°C to 45°C (23°F to 113°F) short term
Short term is </= 1% of operational hours
per year.
NOTE: Reduce maximum
temperature by 1°C/125 meters
(1°F/228 feet) above 950 meters
(3,117 feet).
Operating humidity 5% to 85% (RH), non-condensing,
continuously
5% to 90% (RH), non-condensing, short
term
Short term is </= 1% of operational hours
per year.
Storage temperature -40°C to 70°C (-40°F to 158°F )
Storage humidity 5% to 90%, non-condensing
Maximum thermal output 470 W = 1603.7 BTU/Hr
Maximum operational altitude 10,000 feet (3,048 meters)
Maximum non-operational altitude 39,370 feet (12,000 meters)
Shock Dell EMC Spec SV0115
Table 3. AC power requirements
Parameter Specications
Power supply 100–240 VAC 50/60 Hz
Maximum current draw per system 4.7A/3.9A at 100/120V AC 2.35A/1.95A at
200/240V AC
26 Specications