Install Guide

Table Of Contents
Table 6. QSFP28 port LEDsS5232F-ON, S5248F-ON, and S5296F-ON (continued)
LED Description
OffNo link/activity
Solid greenPort link operating 2x50G
Flashing yellowPort activity at 2x50G port
Flashing yellow, 1 second on/offPort beacon
Link/Activity LED2x50GbE mode First, second, fifth, and sixth LEDs"
OffNo link/activity
Solid greenPort link operating 2x50G
Flashing yellowPort activity at 2x50G port
Flashing yellow, 1 second on/offPort beacon
Prerequisites
The following is a list of components that are required for successful switch installation:
NOTE: For detailed installation instructions, see Site preparations and S5200F-ON Series switch installation.
S5200F-ON Series (S5232F-ON, S5248F-ON, S5296F-ON, S5224F-ON, and S5212F-ON) switch or multiple switches, if
stacking
AC or DC country- and regional-specific cables to connect the AC or DC power source to each switch AC or DC power
supplies
ReadyRail mounting brackets for rack installation, included
Screws for rack installation, not included
#1 and #2 Phillips screw drivers, not included
Torx screwdriver, not included
Ground cable screws for L-bracket, included
Copper/fiber cables
S5212F-ON and S5296F-ON: USB male-female extension cable
Other optional components are:
User-supplied ground cable and separately ordered ground lug for the frame-end of the ground cable
Extra mounting brackets
Extra power supply unit
Extra fan module
NOTE: The DC ground lug kit ships with the other accessories inside the shipping box.
S5200F-ON Series switch configurations
You can order the S5200F-ON Series switch in several different configurations.
S5200F-ON Series AC or DC Normal Airflow switch:
S5212F-ONone-half U, 12 x 25G SFP28 ports, 3 x 100G QSFP28 ports, two AC or DC power supplies, four fan
subsystems with airflow from the I/O side to the power supply side, and one USB male-female extension cable.
S5224F-ONone U, 24 x 25G SFP28 ports, 4 x 100G QSFP28 ports, two AC or DC power supplies, and four fan
subsystems with airflow from the I/O side to the power supply side
S5232F-ONone U, 32 x 100GbE ports, two AC or DC power supplies, and four fan subsystems with airflow from the
I/O side to the power supply side
S5248F-ON one U, 48 x 25GbE ports, 4 x 200GbE ports, 2 x 200GbE QSFP-DD ports, two AC or DC power supplies,
and four fan subsystems with airflow from the I/O side to the power supply side
S5296F-ON two U, 96 x 25GbE ports and 8 x 100GbE ports, two AC or DC power supplies, four fan subsystems with
airflow from the I/O side to the power supply side, and one USB malefemale extension cable
S5200F-ON Series AC or DC Reverse Airflow switch:
S5212F-ONone-half U, 12 x 25G SFP28 ports, 3 x 100G QSFP28 ports, two AC or DC power supplies, four fan
subsystems with airflow from the power supply side to the I/O, and one USB male-female extension cable
S5200F-ON Series switch
19