Setup Guide
Table 2. Environmental parameters
Parameter Specifications
Operating temperature 0° to 45°C (32°F to 113°F) continuously
NOTE: Reduce maximum temperature by 1°C/125
meters (1°F/228 feet) above 950 meters (3,117 feet).
Operating humidity 5% to 85% (RH), non-condensing
Storage temperature –40° to 70°C (–40° to 158°F )
Storage humidity 5% to 90%, non-condensing
Maximum thermal output
S5232F-ON: 635W = 2167 BTU/Hr
S5248F-ON: 647W = 2208 BTU/Hr
S5296F-ON: 893W = 3047 BTU/Hr
S5224F-ON: 455W = 1552 BTU/Hr
S5212F-ON: 304W = 1037 BTU/Hr
Maximum operational altitude 10,000 feet (3,048 meters)
Maximum non-operational altitude 39,370 feet (12,000 meters)
Shock Dell EMC Spec SV0115
Table 3. AC power requirements
Parameter Specifications
Power supply
S5232F-ON: 100–240 VAC 50/60 Hz
S5248F-ON: 100–240 VAC 50/60 Hz
S5296F-ON: 100–240 VAC 50/60 Hz
S5224F-ON: 100-240 VAC 50/60 Hz
S5212F-ON: 100-240 VAC 50/60 Hz
Maximum current draw per system
S5232F-ON: 5.8A@110VAC and 2.4A@220VAC
S5248F-ON: 5.8A@110VAC and 2.4A@220VAC
S5296F-ON: 8.2A@110VAC and 4.1A@220VAC
S5224F-ON: 4.2A@110VAC and 2.1A@220VAC
S5212F-ON: 2.8A@110VAC and 1.4A@220VAC
Maximum power consumption
S5232F-ON: 635W maximum
S5248F-ON: 647W maximum
S5296F-ON: 893W maximum
S5224F-ON: 455W maximum
S5212F-ON: 304W maximum
Typical power consumption
S5232F-ON: 490W typical
S5248F-ON: 420W typical
S5296F-ON: 607W typical
S5224F-ON: 280W typical
S5212F-ON: 208W typical
24 Specifications