Connectivity Guide

27 Dell EMC Networking OS10 Enterprise Edition Switch Configuration Guide for VxRail featuring S5248F-ON,
S5232F-ON and S5148F-ON
S5148F-Leaf1A
S5148F-Leaf1B
no shutdown
vlt-domain 127
backup destination 100.67.172.37
discovery-interface ethernet1/1/53-
1/1/54
peer-routing
end
write memory
no shutdown
vlt-domain 127
backup destination 100.67.172.38
discovery-interface ethernet1/1/53-
1/1/54
peer-routing
end
write memory
7.2 Dual switch without VLT
This example uses a four-node VxRail cluster connected to a switch pair without VLT as shown below.
25GbE connections
100GbE LACP connections,
ports 1/1/53-54
Rack 1
S5148F-Leaf1A S5148F-Leaf1B
LACP
1/1/20 19 18
17 1/1/17 18 19 20
VxRail node 1
VxRail node 2
VxRail node 3
VxRail node 4
Note: The jump box/DNS server, not
shown, is connected to port 1/1/9 on
each switch.
Four-node cluster connected to a switch pair without VLT
In this topology, an LACP port channel is used to connect the two switches.
The commands in the following sections are run to complete the configuration of both switches. The port
numbers used in the configuration commands correspond to those shown in Figure 15.
Note: The commands in the tables below should be entered in the order shown. All commands are provided
in the file attachments named S5148F-1A-no-vlt.txt and S5148F-1B-no-vlt.txt.