Setup Guide
40  Dell EMC SmartFabric OS10 Switch Configuration Guide for VxRail 4.7 
8.1.6  show vrrp brief 
In this deployment, VRRP is configured on the External Management VLAN, 1611, to provide gateway 
redundancy for management traffic. The output from the show vrrp brief command shows the master 
and virtual IP addresses and whether the switch is in the master or backup role. The switch configured with 
the largest priority value, shown in the Priority column, becomes the master. 
S5248F-Leaf1A# show vrrp brief 
Interface Group Priority Prempt State Version Master addr(s) Virtual addr 
-------------------------------------------------------------------------------- 
vlan1611 IPv4 11 150 true master 2 172.16.11.253 172.16.11.254 
Note: For the dual switch without VLT topology, the output is identical to the above. For the single switch 
topology, this command is not applicable. 
8.2  VLT validation commands 
The commands in this section are only applicable to the dual switch with VLT topology. 
8.2.1  show vlt domain_id 
This command is used to validate the VLT configuration status. The Role for one switch in the VLT pair is 
primary, and its peer switch (not shown) is assigned the secondary role. Ensure Peer-Routing is 
Enabled. The VLTi Link Status and VLT Peer Status must both be up. 
S5248F-Leaf1A# show vlt 127 
Domain ID : 127 
Unit ID : 1 
Role : primary 
Version : 2.3 
Local System MAC address : d8:9e:f3:c0:61:00 
Role priority : 32768 
VLT MAC address : d8:9e:f3:bf:ae:00 
IP address : fda5:74c8:b79e:1::1 
Delay-Restore timer : 90 seconds 
Peer-Routing : Enabled 
Peer-Routing-Timeout timer : 0 seconds 
VLTi Link Status 
 port-channel1000 : up 
VLT Peer Unit ID System MAC Address Status IP Address Version 
-------------------------------------------------------------------------------- 
 2 d8:9e:f3:bf:ae:00 up   fda5:74c8:b79e:1::2 2.3 