Deployment Guide
18  Dell EMC Solutions for Microsoft Azure Stack HCI Networking Guide 
13. On the Data Center Bridging (DCB) Settings page, ensure the DCBX Protocol feature is set to 
Disabled. 
  DCBX Protocol setting 
Note: DCBx is a protocol used to exchange PFC and ETS configuration details between devices, such as a 
switch and a network adapter. DCBx is not used in this deployment because Microsoft recommends disabling 
it for S2D deployments. ETS and PFC settings are configured manually on the switch and the network 
adapter later in this guide. 
14. Click Back > Finish > Yes (to save the changes if applicable) > OK (to acknowledge the change 
success message if applicable). 
Repeat steps 5-14 above for the 2
nd
 QLogic QL41262 adapter port. 
15. When complete, exit System Setup and reboot the system. 