Deployment Guide

29 Dell EMC Networking OS10EE FCoE Deployment with FSB
8 S4148U-ON FCF (F_Port) validation
After configuring connected devices, many commands are available to validate the network configuration.
This section provides a list of the most common commands and their output for this topology.
Note: The following commands and outputs are for the S4148U-F-Port-1. The output for the S4148U-F-Port-2
is similar. For more commands and outputs related to the leaf-spine portion of the topology, such as VLT, and
BGP, see
Dell EMC Networking Layer 3 Leaf-Spine Deployment and Best Practices with OS10EE.
8.1 show interface status
The show interface status | grep up command is used to verify that the required interfaces are up,
and links are established at their appropriate speeds.
S4148U-F-Port-1# show interface status | grep up
Port Description Status Speed Duplex Mode Vlan Tagged-Vlans
Eth 1/1/41 up 10G full A 1 -
Fc 1/1/1 up 16G auto -
Fc 1/1/3 up 16G auto -
8.2 show vlan
The show vlan command is used to verify configured VLANs and the interfaces they are applied to.
S4148U-F-Port-1# show vlan
Codes: * - Default VLAN, M - Management VLAN, R - Remote Port Mirroring VLANs,
@ Attached to Virtual Network
Q: A - Access (Untagged), T - Tagged
NUM Status Description Q Ports
* 1 Active A Eth1/1/9-1/1/26,1/1/29-1/1/54
1001 Active T Eth1/1/41
8.3 show fcoe system
The show fcoe system command is used to show FCoE-related information.
S4148U-F-Port-1# show fcoe system
Mode : FPORT
FCOE VLAN List (Operational) : 1001
FCFs : 1
Enodes : 4
Sessions : 4