Administrator Guide
Version Description
8.3.7.0 Introduced on the S4810.
7.8.1.0 The Boot Flash field displays the code level for boot code 2.8.1.1 and newer, while older boot codes
display as "Present".
7.7.1.0 Added Master Priority field.
7.6.1.0 Introduced on the S-Series.
Example (show
system stack unit
– disabled ports)
DellEMC# show system stack-unit 1 disabled-ports
Disabled ports in stack-unit 1
Disabled
52
56
60
Example (show
system brief)
Example (S6000–
ON)
DellEMC> show system stack-unit 1
-- Unit 1 --
Unit Type : Management Unit
Status : Card Problem - Software Failure
Next Boot : online
Required Type : S6000-ON - 32-port TE/FG (SI-ON)
Current Type : S6000-ON - 32-port TE/FG (SI-ON)
Master priority : 0
Hardware Rev : 3.0
Num Ports : 128
Up Time : 3 day, 22 hr, 33 min
Dell EMC Networking OS Version : 9-7(0-288)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Boot Flash : Present
Boot Selector : 3.20.0.0
Memory Size : 3203911680 bytes
Temperature : 0C
Voltage : ok
Serial Number : NA
Part Number : <PART NUMB Rev R>
Vendor Id : NA
Date Code : NA
Country Code : NA
Piece Part ID : <SER:)0
PPID Revision : R>
Service Tag : N/A
Expr Svc Code : 0
Auto Reboot : disabled
Burned In MAC : 00:00:00:00:00:00
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm) Power AvgPower AvgPowerStartTime
--------------------------------------------------------------------------------------
1 1 up AC up 6960 48 31 14/4/2017 17:24
1 2 up AC up 6656 40 26 14/4/2017 17:24
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
--------------------------------------------------
1 1 up up 19275 up 19275
1 2 absent
1 3 up up 19275 up 18904
134
Control and Monitoring