Administrator Guide

Version Description
8.1.1.0 Introduced on the E-Series.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
6.1.1.0 Introduced.
Example
DellEMC(conf-if-range-te-1/2/1,fo-1/2/6)# show range
2/2/1 - 0
2/56 - 0
Related
Commands
interface — configure a physical interface on the switch.
show ip interface — display Layer 3 information about the interfaces.
shutdown
Disable an interface.
Syntax
shutdown
To activate an interface, use the no shutdown command.
Defaults The interface is disabled.
Command Modes INTERFACE
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.8(2.0) Introduced on the S3100 series.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.1.1.0 Introduced on the E-Series.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
E-Series legacy
command
Usage Information
The shutdown command marks a physical interface as unavailable for traffic. To discover if an interface is
disabled, use the show ip interface brief command. Disabled interfaces are listed as down.
Disabling a VLAN or a port channel causes different behavior. When a VLAN is disabled, the Layer 3 functions
within that VLAN are disabled. Layer 2 traffic continues to flow. Entering the shutdown command on a port
Interfaces 685