Dell Command Line Reference Guide for the S6000– ON System 9.8(0.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright, 2009 – 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 About this Guide............................................................................................................ 37 Objectives.........................................................................................................................................................................37 Audience...........................................................................................................................................................................
Control and Monitoring..................................................................................................78 banner exec......................................................................................................................................................................78 banner login......................................................................................................................................................................79 banner motd...............
show processes memory.................................................................................................................................................126 show software ifm.......................................................................................................................................................... 128 show system...........................................................................................................................................................
deny..........................................................................................................................................................................170 ip access-list standard...............................................................................................................................................172 permit..............................................................................................................................................................
match ip next-hop....................................................................................................................................................220 match ip route-source...............................................................................................................................................221 match metric............................................................................................................................................................
deny udp (for IPv6 ACLs).............................................................................................................................................. 269 deny arp (for Extended MAC ACLs)................................................................................................................................271 deny tcp (for IPv6 ACLs)................................................................................................................................................
bgp confederation identifier..................................................................................................................................... 302 bgp confederation peers.......................................................................................................................................... 303 bgp dampening........................................................................................................................................................
neighbor remove-private-as..................................................................................................................................... 343 neighbor route-map..................................................................................................................................................344 neighbor route-reflector-client.................................................................................................................................
cam-optimization..................................................................................................................................................... 399 show cam-acl...........................................................................................................................................................399 test cam-usage.........................................................................................................................................................
dcb-policy buffer-threshold (Interface Configuration).................................................................................................... 438 show qos dcb-buffer-threshold...................................................................................................................................... 438 dcb pfc-total-buffer-size................................................................................................................................................
network.................................................................................................................................................................... 481 pool...........................................................................................................................................................................481 show ip dhcp binding.........................................................................................................................................
16 Flex Hash and Optimized Boot-Up.............................................................................. 511 load-balance ingress-port enable..................................................................................................................................... 511 load-balance flexhash...................................................................................................................................................... 511 reload-type fastboot.............................
protocol gvrp................................................................................................................................................................. 545 show config................................................................................................................................................................... 546 show garp timers..........................................................................................................................................
interface range.........................................................................................................................................................586 interface range macro (define).................................................................................................................................588 interface range macro name....................................................................................................................................
arp timeout.................................................................................................................................................................... 643 clear arp-cache.............................................................................................................................................................. 644 clear host................................................................................................................................................
show ip route summary..................................................................................................................................................696 show ip traffic................................................................................................................................................................ 697 show tcp statistics..............................................................................................................................................
graceful-restart restart-wait...........................................................................................................................................738 graceful-restart t1...........................................................................................................................................................739 graceful-restart t2...............................................................................................................................................
27 Link Aggregation Control Protocol (LACP)................................................................. 781 clear lacp counters.......................................................................................................................................................... 781 debug lacp......................................................................................................................................................................782 lacp long-timeout........................
advertise dot1-tlv...................................................................................................................................................... 818 advertise dot3-tlv..................................................................................................................................................... 819 clear lldp counters....................................................................................................................................................
show ip msdp sa-cache rejected-sa............................................................................................................................... 853 32 Multiple Spanning Tree Protocol (MSTP)..................................................................855 debug spanning-tree mstp............................................................................................................................................. 855 disable..........................................................
router-preference maximum.....................................................................................................................................888 show config............................................................................................................................................................. 889 show ipv6 nd ra-guard policy...................................................................................................................................
graceful-restart helper-reject....................................................................................................................................927 graceful-restart mode.............................................................................................................................................. 928 graceful-restart role.................................................................................................................................................
timers throttle lsa all................................................................................................................................................. 978 timers throttle lsa arrival...........................................................................................................................................979 OSPFv3 Commands.......................................................................................................................................................
debug ip pim............................................................................................................................................................1021 ip pim bsr-border.................................................................................................................................................... 1022 ip pim bsr-candidate...............................................................................................................................................
tc-flush-standard..........................................................................................................................................................1065 vlan bridge-priority....................................................................................................................................................... 1066 vlan forward-delay.............................................................................................................................................
show qos qos-policy-output.................................................................................................................................... 1100 show qos statistics...................................................................................................................................................1101 show qos wred-profile.............................................................................................................................................
show running-config rip................................................................................................................................................. 1141 timers basic....................................................................................................................................................................1141 version......................................................................................................................................................
Obscure Password Commands.......................................................................................................................................1181 service obscure-passwords...................................................................................................................................... 1181 Authentication and Password Commands.....................................................................................................................
dot1x reauthentication............................................................................................................................................. 1218 dot1x reauth-max.................................................................................................................................................... 1219 dot1x server-timeout...............................................................................................................................................
47 Service Provider Bridging.........................................................................................1253 debug protocol-tunnel.................................................................................................................................................. 1253 protocol-tunnel............................................................................................................................................................. 1254 protocol-tunnel destination-mac........
default logging console........................................................................................................................................... 1292 default logging monitor........................................................................................................................................... 1293 default logging trap.................................................................................................................................................
spanning-tree................................................................................................................................................................1334 53 System Time and Date............................................................................................. 1337 clock summer-time date................................................................................................................................................1337 clock summer-time recurring.............
ip unknown-unicast....................................................................................................................................................... 1371 ipv6 unknown-unicast....................................................................................................................................................1371 description.........................................................................................................................................................
vlt domain.....................................................................................................................................................................1404 vlt-peer-lag port-channel..............................................................................................................................................1405 59 Virtual Extensible LAN (VXLAN)..............................................................................1406 feature vxlan..............................
1 About this Guide This book provides information about the Dell Networking OS command line interface (CLI). This book also includes information about the protocols and features found in Dell Networking OS.
Information Icons This book uses the following information symbols: NOTE: The Note icon signals important operational information. CAUTION: The Caution icon signals information about situations that could result in equipment damage or loss of data. WARNING: The Warning icon signals information about hardware handling that could result in injury.
2 CLI Basics This chapter describes the command line interface (CLI) structure and command modes. The Dell Networking operating software commands are in a text-based interface that allows you to use the launch commands, change command modes, and configure interfaces and protocols. Accessing the Command Line When the system boots successfully, you are positioned on the command line in EXEC mode and not prompted to log in. You can access the commands through a serial console port or a Telnet session.
In this case, the user is “admin” on vty2. Obtaining Help As soon as you are in a command mode there are several ways to access help. To obtain a list of keywords at any command mode: Type a ? at the prompt or after a keyword. There must always be a space before the ?. To obtain a list of keywords with a brief functional description: Type help at the prompt. To obtain a list of available options: Type a keyword and then type a space and a ?.
• To navigate left or right in the Dell Networking OS command line, use the left and right Arrow keys. The shortcut key combinations at the Dell Networking OS command line are as follows: Key Combination Action CNTL-A Moves the cursor to the beginning of the command line. CNTL-B Moves the cursor back one character. CNTL-D Deletes the character at the cursor. CNTL-E Moves the cursor to the end of the line. CNTL-F Moves the cursor forward one character. CNTL-I Completes a keyword.
Using the Keyword no Command To disable, delete or return to default values, use the no form of the commands. For most commands, if you type the keyword no in front of the command, you disable that command or delete it from the running configuration. In this guide, the no form of the command is described in the Syntax portion of the command description.
Enabling Software Features on Devices Using a Command Option This capability to activate software applications or components on a device using a command is supported on the S4810, S4820T, and S6000, platforms. Starting with Release 9.4(0.0), you can enable or disable specific software functionalities or applications that need to run on a device by using a command attribute in the CLI interface.
show feature Verify the status of software applications, such as VRF, that are activated and running on a device. Syntax show feature Command Modes EXEC EXEC Privilege Command History Version 9.4(0.0) Introduced on the S4810, S4820T, and S6000. Usage Information You can activate VRF application on a device by using the feature vrf command in CONFIGURATION mode. The no feature vrf command is not supported on any of the platforms.
1. Verify that you are logged in to EXEC Privilege mode. 2. Enter the configure command. The prompt changes to include (conf). From this mode, you can enter INTERFACE mode by using the interface command. CONTROL-PLANE Mode To manage control-plane traffic, use CONTROL-PLANE mode. For more information, refer to Control Plane Policing (CoPP). To enter CONTROL-PLANE mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the control-plane-cpuqos command.
EXEC Mode When you initially log in to the switch, by default, you are logged in to EXEC mode. This mode allows you to view settings and enter EXEC Privilege mode, which is used to configure the device. When you are in EXEC mode, the > prompt is displayed following the host name prompt, which is “Dell” by default. You can change the host name prompt using the hostname command. NOTE: Each mode prompt is preceded by the host name. EXEC Privilege Mode The enable command accesses EXEC Privilege mode.
Prompt Interface Type Dell(conf-ifte-1/1)# Ten-Gigabit Ethernet interface then slot/port/subport information Dell(conf-iffo-1/1)# Forty-Gigabit Ethernet interface then slot/port information Dell(conf-iflo-0)# Loopback interface number Dell(conf-ifnu-0)# Null Interface then zero Dell(conf-ifpo-0)# Port-channel interface number Dell(conf-ifvl-0)# VLAN Interface then VLAN number (range 1–4094) Dell(conf-ifma-1/1)# Management Ethernet interface then slot/port information Dell(conf-iftu-0)# Tunn
2. Enter the protocol lldp command. The prompt changes to include (conf-lldp) or (conf-if-interface-lldp). LLDP MANAGEMENT INTERFACE Mode To enable and configure Link Layer Discovery Protocol (LLDP) on management interfaces, use LLDP MANAGEMENT INTERFACE mode. To enter LLDP MANAGEMENT INTERFACE mode: 1. Verify that you are logged in to LLDP mode. 2. Enter the management-interface command. The prompt changes to include (conf-lldp-mgmtIf).
To enter OPENFLOW INSTANCE mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the openflow of-instance command then the OpenFlow ID number of the instance you want to create or configure. The prompt changes to include (conf-of-instance of-id). You can return to the CONFIGURATION mode by entering the exit command. Per-VLAN SPANNING TREE (PVST+) Plus Mode To enable and configure the Per-VLAN Spanning Tree (PVST+) protocol, use PVST+ mode.
1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the protocol spanning-tree rstp command. The prompt changes to include (conf-rstp). You can return to CONFIGURATION mode by using the exit command. ROUTE-MAP Mode To configure a route map, use ROUTE-MAP mode. To enter ROUTE-MAP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Use the route-map map-name [permit | deny] [sequence-number] command. The prompt changes to include (config-route-map).
2. Enter the ipv6 router ospf {process-id} command. The prompt changes to include (conf-ipv6-router_ospf). You can return to CONFIGURATION mode by using the exit command. ROUTER RIP Mode To enable and configure Router Information Protocol (RIP), use ROUTER RIP mode. For more information, refer to Routing Information Protocol (RIP). To enter ROUTER RIP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the router rip command. The prompt changes to include (conf-router_rip).
3 File Management This chapter contains command line interface (CLI) commands needed to manage the configuration files as well as other file management commands. boot system Tell the system where to access the Dell Networking OS image used to boot the system. Syntax boot system {gateway ip address| stack-unit [{stack-unit-number | all] [default | primary {system {A: | B: | bmp-boot} | tftp: | | secondary]} To return to the default boot sequence, use the no boot system command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced the support for bmp-boot on the S-Series and Z-Series switches. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. HTTP Copy via CLI Copy one file to another location. Dell Networking OS supports IPv4 and IPv6 addressing for FTP, TFTP, and SCP (in the hostip field). This feature is supported on platform. Syntax copy http://10.16.206.77/sample_file flash://sample_filecopy flash:// sample_file http://10.16.206.
copy Copy one file to another location. Dell Networking OS supports IPv4 and IPv6 addressing for FTP, TFTP, and SCP (in the hostip field). Syntax copy compressed-config source-file-url destination-file-url Parameters Enter the following location keywords and information: compressed-config file-url Enter the keyword compressed-config to copy one file, after optimizing and reducing the size of the configuration file, to another location.
To copy a file on the external FLASH enter slot0:// followed by the filename To copy a file on a TFTP server enter tftp://hostip/filepath To copy a file from an external USB drive enter usbflash://filepath Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
• copy running-config tftp: • copy running-config ftp: • copy running-config nfsmount:///filepath You can compress the running configuration by grouping all the VLANs and the physical interfaces with the same property. Support to store the operating configuration to the startup config in the compressed mode and to perform an image downgrade without any configuration loss are provided.
Parameters flash-url Enter the following location and keywords: • For a file or directory on the internal Flash, enter flash:// followed by the filename or directory name. • For a file or directory on the NFS mounted file system, enter nfsmount:// followed by the mount point and the file path. NOTE: While deleting a file directory on a remote NFS file system, it is mandatory to specify the mount-point that indicates the working directory on the NFS file system.
NOTE: While displaying a file directory on a remote NFS file system, it is mandatory to specify the mount-point that indicates the working directory on the NFS file system. You cannot display details corresponding to the root directory of the remote NFS file system. • For a file or directory on the external Flash, enter usbflash:// then the filename or directory name. Command Modes EXEC Privilege Command History This guide is platform-specific.
format (S-Series) Erase all existing files and reformat the filesystem in the internal flash memory. After the filesystem is formatted, files cannot be restored. Syntax format {flash: | usbflash:} Defaults None Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Introduced on S4810 and Z9000. 8.3.19.0 Introduced on S4820T. Include the colon (:) when entering this command.
mount nfs Mounts an NFS file system to a device. Syntax mount nfs rhost:path mount-point [username password] Parameters Enter the following location keywords and information: rhost:path Enter the remote hosts’s path directory. mount-point Enter the folder name in the local file system. username (OPTIONAL) Enter the user name to access the device. password (OPTIONAL) Enter the password. Command Modes CONFIGURATION Command History This guide is platform-specific.
upgrade system Upgrade the Dell Networking OS image. To upgrade the bootflash or bootselector image, use the upgrade boot command. Syntax Parameters upgrade system {flash: | ftp: | nfsmount: | scp: | stack-unit {stack-unit-id | all} system Enter the keyword system to upgrade the operating system (OS) image.
Example Dell# upgrade system tftp://10.11.8.12/dv-rainier-13 a: 00:39:32 : Discarded 1 pkts. Expected block num : 51. Received block num: 50 !00:39:36 : Discarded 1 pkts. Expected block num : 65. Received block num: 64 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! 93924044 bytes successfully copied System image upgrade completed successfully.
Parameters all Enter the keyword all to display the boot image information for all stack units. stack-unit Enter the keyword stack-unit followed by a number to display boot image information for a stack-unit. The range is from 1 to 6. Defaults Command Modes Command History none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.4 Output expanded to display current reload mode (normal or Jumpstart). 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.5.1.0 Introduced on the C-Series. E-Series Original command. Dell#show bootvar PRIMARY IMAGE FILE = system://B SECONDARY IMAGE FILE = tftp://10.16.127.35/Dell-SI-9-0-2-0.
Example Command Fields Version Description E-Series Original command Dell#show file-systems Size(b) Free(b) Feature Type Flags Prefixes 63938560 51646464 dosFs2.0 MMC rw flash: 63938560 18092032 dosFs1.0 MMC rw slot0: - - - network rw ftp: - - - network rw tftp: - - - network rw scp: Dell# Field Description size(b) Lists the size (in bytes) of the storage location. If the location is remote, no size is listed. Free(b) Lists the available size (in bytes) of the storage location.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
ethernet for the current Ethernet CFM configuration fefd for the current FEFD configuration ftp for the current FTP configuration frrp for the current FRRP configuration fvrp for the current FVRP configuration gvrp for the current GVRP configuration host for the current host configuration hardwaremonitor for hardware-monitor action-on-error settings hypervisor for the current hypervisor configuration igmp for the current IGMP configuration interface for the current interface configurati
policy-mapoutput for the current output policy map configuration po-failovergroup for the current port-channel failover-group configuration prefix-list for the current prefix-list configuration privilege for the current privilege configuration qos-policyinput for the current input QoS policy configuration qos-policyoutput for the current output QoS policy configuration radius for the current RADIUS configuration redirect-list for the current redirect-list configuration redundancy for th
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Added support for the tunnel and EIS interface types. 9.0.0.0 Added support for the VLT option. 8.3.19.
show startup-config Display the startup configuration. Syntax show startup-config Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Command Fields Example (S-Series) Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series 7.5.1.0 Introduced on the C-Series. E-Series Original command. Lines Beginning With Description Dell Network... Name of the operating system Dell Operating... OS version number Dell Application...
Example (S4810) Dell# Dell#show version Dell Real Time Operating System Software Dell Operating System Version: 1.0 Dell Application Software Version: Z9K-ICC-PRIM-SYNC-8-3-11-173 Copyright (c) 1999-2012 by Dell Inc. All Rights Reserved. Build Time: Mon Jul 16 22:19:01 PDT 2012 Build Path: /local/local/build/build15/8.3.12.0/SW/SRC/Radius Dell uptime is 1 minute(s) System image file is "s4810-14" System Type: S4810 Control Processor: Freescale QorIQ P2020 with 2147483648 bytes of memory.
usbflash Enter the keyword flash to follow it with the location of the source file in this form: //filepath, or press Enter to launch a prompt sequence. A Enter the keywordA to upgrade the bootflash partition A B Enter the keyword B to upgrade the bootflash partition B. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
all Enter the keywords all to upgrade the member stack-units. booted Enter the keyword booted to upgrade from the current image in the S6000. ftp Enter the keyword ftp to follow it with the location of the source file in this form: //userid:password@hostip/filepath, or press Enter to launch a prompt sequence. tftp Enter the keyword tftp to follow it with the location of the source file in this form: //hostlocation/filepath, or press Enter to launch a prompt sequence.
verify Validate the software image on the flash drive after the image has been transferred to the system, but before the image has been installed. Syntax Parameters verify { md5 | sha256 }[ flash:// ] img-file [hash-value] md5 Enter the md5 keyword to use the MD5 message-digest algorithm. sha256 Enter the sha256 keyword to use the SHA256 Secure Hash Algorithm flash:// (Optional). Enter the flash:// keyword. The default is to use the flash drive. You can just enter the image file name.
4 Control and Monitoring This chapter contains the commands to configure and monitor the system, including Telnet, file transfer protocol (FTP), and trivial file transfer protocol (TFTP). NOTE: This command replaces the enable optic-info-update interval command to update information on temperature and power monitoring in the simple network management protocol (SNMP) management information base (MIB). banner exec Configure a message that is displayed when your enter EXEC mode.
Version Description E-Series Original Command Usage Information After entering the banner login command, type one or more spaces and a delineator character. Enter the banner text then the second delineator character. When the user is connected to the router, if a message of the day banner is configured, it displays first. If no message of the day banner is configured, the login banner and prompt appear. After the user has logged in, the banner EXEC (if configured) displays.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.2.1.0 Introduced the keyword keyboard-interactive.
banner motd Set a message of the day (MOTD) banner. Syntax banner motd c line c To delete a Message of the Day banner, enter no banner motd. Parameters c Enter a delineator character to specify the limits of the text banner. The delineator is a percent character (%). line Enter a text string for your MOTD banner the message with your delineator. The delineator is a percent character (%). Defaults No banner is configured.
cam-acl Allocate content addressable memory (CAM) for IPv4 and IPv6 ACLs.
Usage Information Version Description 8.3.1.0 Added the keywords ecfmacl, vman-qos, and vman-dual-qos. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series. For the new settings to take effect, save the new CAM settings to the startup-config (write-mem or copy run start) then reload the system. The total amount of space allowed is 16 FP Blocks. System flow requires three blocks and these blocks cannot be reallocated. The ipv4acl profile range is from 1 to 4.
Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. configure Enter CONFIGURATION mode from EXEC Privilege mode. Syntax configure [terminal] Parameters terminal (OPTIONAL) Enter the keyword terminal to specify that you are configuring from the terminal. Command Modes EXEC Privilege Command History This guide is platform-specific.
Parameters level (OPTIONAL) Enter a number for a privilege level of the Dell Networking OS. The range is from 0 to 15. The default is 1. Defaults 1 Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Usage Information Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. Users entering EXEC Privilege mode or any other configured privilege level can access configuration commands.
Usage Information Version Description 8.3.10.0 Replacement command for the S4810 only. Replaces the enable xfp-powerupdates command. To enable polling and to configure the polling frequency, use this command. end Return to EXEC Privilege mode from other command modes (for example, CONFIGURATION or ROUTER OSPF modes).
Related Commands exit — returns to the lower command mode. exec-timeout Set a time interval that the system waits for input on a line before disconnecting the session. Syntax exec-timeout minutes [seconds] To return to default settings, use the no exec-timeout command. Parameters minutes Enter the number of minutes of inactivity on the system before disconnecting the current session. The range is from 0 to 35791. The default is 10 minutes for the console line and 30 minutes for the VTY line.
Command Modes Command History • EXEC Privilege • CONFIGURATION • LINE, INTERFACE • TRACE-LIST • PROTOCOL GVRP • SPANNING TREE • MULTIPLE SPANNING TREE • MAC ACCESS LIST • ACCESS-LIST • AS-PATH ACL • COMMUNITY-LIST • PREFIX-LIST • ROUTER OSPF • ROUTER RIP • ROUTER ISIS • ROUTER BGP This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.
Usage Information Version Description E-Series Original command. The hostname is used in the prompt. ip ftp password Specify a password for outgoing FTP connections. Syntax ip ftp password [encryption-type] password To remove a password and return to the default setting, use the no ip ftp password [password] command.
Related Commands ip ftp username — sets the user name for the FTP sessions. ip ftp source-interface Specify an interface’s IP address as the source IP address for FTP connections. Syntax ip ftp source-interface interface To delete an interface, use the no ip ftp source-interface interface command.
ip tftp vrf Configures an TFTP client with a VRF that is used to connect to the TFTP server. Syntax ip tftp [vrf vrf-name] To undo the TFTP client configuration, use the no ip tftp [vrf vrf-name] command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to specify the VRF that is used by the TFTP client. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command.
ip telnet server enable Enable the Telnet server on the switch. Syntax ip telnet server enable To disable the Telnet server, use the no ip telnet server enable command. Defaults Enabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.4.(0.0) Introduced on the S-Series and Z9000.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.2.1.0 Increased number of VLANs on ExaScale to 4094 (was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series.
Related Commands ftp-server topdir — sets the directory to be used for incoming FTP connections. ftp-server username — sets a username and password for incoming FTP connections. line Enable and configure console and virtual terminal lines to the system. This command accesses LINE mode, where you can set the access conditions for the designated line. Syntax Parameters line {aux 0 |console 0 | vty number [end-number]} aux 0 Enter the keyword aux 0 to configure the auxiliary terminal connection.
login concurrent-session Configures the limit of concurrent sessions for all users on console and virtual terminal lines. Syntax login concurrent-session {limit number-of-sessions | clear—line enable} no login concurrent-session {limit number-of-sessions | clear—line enable} Parameters limit number-ofsessions Sets the number of concurrent sessions that any user can have on console and virtual terminal lines. The range is from 1 to 12 (10 VTY lines, one console, and one AUX line).
Login: admin Password: Current sessions for user admin: Line Location 2 vty 0 10.14.1.97 3 vty 1 10.14.1.97 Clear existing session? [line number/Enter to cancel]: When you try to create more than the permitted number of sessions, the following message appears, prompting you to close one of your existing sessions. Close any of your existing sessions to log in to the system. $ telnet 10.11.178.14 Trying 10.11.178.14... Connected to 10.11.178.14. Escape character is '^]'.
Usage Information Version Description 9.8(0.0) Introduced on the S4810, S4820, S5000, S6000, S6000-ON, and Z9500. Only the system and security administrators can configure login activity tracking and view the login activity details of other users. If you enable user login statistics, the system displays the last successful login details of the current user and the details of any failed login attempts by others.
motd-banner Enable a message of the day (MOTD) banner to appear when you log in to the system. Syntax motd-banner To disable the MOTD banner, use the no motd-banner command. Defaults Enabled on all lines. Command Modes LINE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
count Enter the number of echo packets to be sent. The default is 5. • number: from 1 to 2147483647 • continuous: transmit echo request continuously datagram size Enter the ICMP datagram size. The range is from 36 to 15360 bytes. The default is 100. timeout Enter the interval to wait for an echo reply before timing out. The range is from 0 to 3600 seconds. The default is 2 seconds. source Enter the IPv4 or IPv6 source ip address or the source interface.
Defaults Command Modes Command History • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. none • EXEC • EXEC Privilege This guide is platform-specific.
Example (IPv4) Symbol Description . Each period indicates the network server timed out while waiting for a reply. U A destination unreachable error PDU was received. Q Source quench (destination too busy). M Could not fragment. ? Unknown packet type. & Packet lifetime exceeded. Dell#ping 172.31.1.255 Type Ctrl-C to abort. Sending 5, 100-byte ICMP Echos to 172.31.1.255, timeout is 2 seconds: Reply to request 1 from 172.31.1.208 0 ms Reply to request 1 from 172.31.1.
Usage Information Version Description 9.0.0.0 Introduced on the Z9000. 9.1(0.0) Added ‘conditional’ parameter. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. If there is a change in the configuration, FTOS prompts you to save the new configuration. Or you can save your running configuration with the copy running-config command.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced on the E-Series. Messages can contain an unlimited number of lines; however, each line is limited to 255 characters. To move to the next line, use . To send the message use CTR-Z; to abort a message, use CTR-C. service timestamps To debug and log messages, add time stamps. This command adds either the uptime or the current time and date.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. If you do not specify parameters and enter service timestamps, it appears as service timestamps debug uptime in the running-configuration. To view the current options set for the service timestamps command, use the show runningconfig command. show alarms View alarms currently active in the system.
---------------------------------------------RPM 0 PEM A failed or rmvd 7 hr, 37 min SFM 0 PEM A failed or rmvd 7 hr, 37 min SFM 1 PEM A failed or rmvd 7 hr, 37 min SFM 2 PEM A failed or rmvd 7 hr, 37 min SFM 3 PEM A failed or rmvd 7 hr, 37 min SFM 4 PEM A failed or rmvd 7 hr, 37 min SFM 5 PEM A failed or rmvd 7 hr, 37 min SFM 6 PEM A failed or rmvd 7 hr, 37 min SFM 7 PEM A failed or rmvd 7 hr, 36 min stack-unit 1 PEM A failed or rmvd 7 hr, 36 min stack-unit 4 PEM A failed or rmvd 7 hr, 36 min only 8 SFMs i
Example Dell#show command-tree count ! Enable privilege mode: enable command usage:3 <0-15> option usage: 0 exit command usage:1 show command-tree command usage:9 count option usage: 3 show version command usage:1 ! Global configuration mode: aaa authentication enable command usage:1 WORD option usage: 1 default option usage: 0 enable option usage: 0 line option usage: 0 none option usage: 0 radius option usage: 1 tacacs+ option usage: 0 show cpu-traffic-stats View the CPU traffic statistics.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series 6.2.1.1 Introduced on the E-Series. Traffic statistics are sorted on a per-interface basis; the interface receiving the most traffic is displayed first. All CPU and port information is displayed unless a specific port or CPU is specified. Traffic information is displayed for router ports only; not for management interfaces.
Version Description 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series E-Series Original command. Example show environment View S-Series and Z-Series system component status (for example, temperature or voltage).
Example (all) Dell#show environment -- Fan Status -Unit Bay TrayStatus Fan0 Speed Fan1 Speed -----------------------------------------------------------------------------------0 0 up up 6971 up 7072 0 1 up up 6971 up 7021 0 2 up up 7021 up 7021 Speed in RPM -- Power Supplies -Unit Bay Status Type FanStatus FanSpeed(rpm) --------------------------------------------------------------------------0 0 down UNKNOWN down 0 0 1 up AC up 6504 -- Unit Environment Status -Unit Status Temp Voltage TempStatus --------
Parameters media slot (OPTIONAL) Enter the keyword media then the stack ID of the stack member for which you wan NOTE: This parameter is available but not supported in Dell Networking Operating Syste supported, if you use this parameter, the output displays “Media not present or accessib Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
0 0 0 0 Related Commands • 7 8 9 10 QSFP QSFP QSFP QSFP 40GBASE-CR4-1M 40GBASE-CR4-1M 40GBASE-CR4-1M 40GBASE-CR4-1M APF11200012UR1 APF12300017GEY APF12300017GEY APF12300017GEY Yes Yes Yes Yes show interfaces — displays the interface configuration. show login statistics Displays login statistics of users who have used the console or virtual terminal lines to log in to the system.
To view the successful and failed login details of a specific user in the last 30 days or the custom defined time period, use the show login statistics user user-id command. If you have system or security administrator rights, you can view the login statistics of other users. If you do not have system or security administrator rights, you can view your login statistics but not the login statistics of others. NOTE: By default, these commands display the details for the last 30 days.
The following is sample output of the show login statistics unsuccessful-attempts timeperiod days command. Dell#show login statistics unsuccessful-attempts time-period 15 There were 0 unsuccessful login attempt(s) for user admin in last 15 day(s). The following is sample output of the show login statistics unsuccessful-attempts user login-id command. Dell#show login statistics unsuccessful-attempts user admin There were 3 unsuccessful login attempt(s) for user admin in last 12 day(s).
Example Dell#show memory stack-unit 1 Statistics On Unit 1 Processor =========================== Total(b) Used(b) Free(b) Lowest(b) Largest(b) 268435456 4010354 264425102 264375410 264425102 Example (S4820T) Dell#show memory stack 0 Statistics On Unit 0 Processor =========================== Total(b) Used(b) Free(b) Lowest(b) Largest(b) 2147483648 4322398 2143161250 2142548382 2143161250 Dell# show processes cpu Display CPU usage information based on processes running.
Example Version Description 8.3.7.0 Introduced on the S4810. 7.7.1.0 Added the keywords management-unit [details]. 7.6.1.0 Introduced on the S-Series.
CORE 2 Overall 11.73 11.73 12.05 11.42 14.31 13.56 PID Runtime(ms) Invoked uSecs TTY Process Process: system PID: 0 CPU usage: 5sec 5min - 12.94% CoreID: 3 Process: sysdlp PID: 428 CPU usage: 5sec 5min - 3.40% CoreID: 0 Process: sysd PID: 410 CPU usage: 5sec 5min - 2.50% CoreID: 2 TID Runtime(ms) Invoked uSecs 5Min TTY Thread 56 20 2 10000 0.00% 0 usm 55 10 1 10000 0.00% 0 DHCLIENT 54 0 0 0 0.00% 0 cms 53 60 6 10000 0.00% 0 portmirr 52 0 0 0 0.00% 0 cfgDataSync 51 0 0 0 0.
0x00000132 420 0 vrrp 0x0000028d 410 0 ovsdbsvr 0x000000a9 200 0 arpm 0x00000253 100 0 otm 0x00000206 140 0 tnlmgr 0x00000012 1290 0 mount_mfs 0x0000024d 400 0 xstp Related Commands 42 10000 0.20% 0.10% 0.13% 41 10000 0.20% 0.05% 0.12% 20 10000 0.20% 0.03% 0.06% 10 10000 0.20% 0.02% 0.02% 14 10000 0.20% 0.02% 0.03% 129 10000 0.00% 0.10% 0.12% 40 10000 0.00% 0.08% 0.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series and E-Series.
show processes memory Display memory usage information based on processes running in the S-Series or Z-Series system. Syntax show processes memory {management-unit | stack unit {unit-id | all | summary}} Parameters Command Modes Command History management-unit Enter the keyword management-unit for CPU memory usage of the stack management unit. stack unit unit id Enter the keyword stack unit then a stack unit ID of the member unit for which to display memory usage on the forwarding processor.
show processes memory output Description Process Process Name ResSize Actual resident size of the process in memory Size Process test, stack, and data size Allocs Total dynamic memory allocated Frees Total dynamic memory freed Max Maximum dynamic memory allocated Current Current dynamic memory in use Field The output for the show process memory command displays the memory usage statistics running on CP part (sysd) of the system.
273 acl 5005312 512000 239564 149076 123616 272 topoDPC 117927936 0 0 0 0 271 bcmNHOP 117927936 0 0 0 0 270 bcmDISC 117927936 0 0 0 0 269 bcmATP-RX 117927936 0 0 0 0 268 bcmATP-TX 117927936 0 0 0 0 267 bcmSTACK 117927936 0 0 0 0 266 bcmRX 117927936 0 0 0 0 265 bcmLINK.0 117927936 0 0 0 0 !----------- output truncated --------------! 90488 0 0 0 0 0 0 0 0 show software ifm Display interface management (IFM) data.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 7.6.1.0 Introduced for the C-Series and S-Series.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Added support for the disabled-ports parameter . 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.11.4 The brief parameter no longer displays the current Reload mode. To display Reload mode, use the show reload-type command.
Speed in RPM Example (S6000) Dell#show system Stack MAC : 90:b1:1c:f4:9b:79 Reload-Type : normal-reload [Next boot : normal-reload] -- Unit 0 -Unit Type : Management Unit Status : online Next Boot : online Required Type : S6000 - 32-port TE/FG (SI) Current Type : S6000 - 32-port TE/FG (SI) Master priority : 0 Hardware Rev : 4.
Master priority : 0 Hardware Rev : 4.0 Num Ports : 128 Up Time : 21 min, 8 sec Dell Networking OS Version : 9-4(0-168) Jumbo Capable : yes POE Capable : no FIPS Mode : disabled Boot Flash : 3.1.1.2 Boot Selector : 3.1.0.
PPID Revision Service Tag Expr Svc Code Auto Reboot Burned In MAC No Of MACs : : : : : : R> N/A 0 disabled 00:00:00:00:00:00 3 -- Power Supplies -Unit Bay Status Type FanStatus FanSpeed(rpm) --------------------------------------------------------------------------1 1 up AC up 18528 1 2 absent absent 0 -- Fan Status -Unit Bay TrayStatus Fan1 Speed Fan2 Speed -----------------------------------------------------------------------------------1 1 up up 19275 up 19275 1 2 absent 1 3 up up 19275 up 18904 Spe
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced save to the file options. 7.6.1.0 Introduced on the S-Series. Without the page or stack-unit option, the command output is continuous. To interrupt the command output, use Ctrl-z. The save option works with other filtering commands.
no-more save Don't paginate output Save output to a file Dell#show tech-support stack-unit 1 | save ? flash: Save to local file system (flash://filename (max 20 chars) ) Dell#show tech-support stack-unit 1 | save flash://LauraSave Start saving show command report ....... Dell# Dell#dir Directory of flash: 1 drw- 16384 Jan 01 1980 00:00:00 +00:00 . 2 drwx 1536 Jul 13 1996 02:38:06 +00:00 ..
hardware watchdog stack-unit 3 hardware watchdog stack-unit 4 hardware watchdog stack-unit 5 ! Related Commands ssh-peer-stack-unit Open an SSH connection to the peer stack-unit. Syntax ssh-peer-stack-unit [-l username] Parameters Defaults -l username (OPTIONAL) Enter the keyword -l then your user name. The default is the user name associated with the terminal. Not configured. Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
ip-address Enter the IPv4 address in dotted decimal format of the server. ipv6-address prefixlength Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros. Defaults Command Modes Command History vrf instance (Optional) Enter the keyword vrf then the VRF instance name.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series and added support for IPv6 address on the E-Series only. The VRF configured using this command has a higher precedence than a VRF configured using the ip telent vrf vrf-name command. If you do not use the VRF attribute in this command, then TELENT client uses the VRF configured using the ip telnet vrf vrf-name command.
terminal length Configure the number of lines displayed on the terminal screen. Syntax Parameters Defaults Command Modes Command History terminal length screen-length screen-length Enter a number of lines. Entering zero causes the terminal to display without pausing. The range is from 0 to 512. 24 lines • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Command Modes Command History • Timeout = 5 seconds • Probe count = 3 • 30 hops max • 40 byte packet size • UDP port = 33434 • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
2 gwegress-sjc-02.Dell Networking.com (10.11.30.126) 005.000 ms 001.000 ms 001.000 ms 3 fw-sjc-01.Dell Networking.com (10.11.127.254) 000.000 ms 000.000 ms 000.000 ms 4 www.Dell Networking.com (10.11.84.18) 000.000 ms 000.000 ms 000.000 ms FTOS# Example (IPv6) Dell#traceroute 100::1 Type Ctrl-C to abort. ----------------------------------------------Tracing the route to 100::1, 64 hops max, 60 byte packets ----------------------------------------------Hops Hostname Probe1 Probe2 Probe3 1 100::1 000.
Version Description 7.5.1.0 Introduced on the C-Series. E-Series Original command virtual-ip Configure a virtual IP address for the active management interface. You can configure virtual addresses both for IPv4 and IPv6 independently. Syntax virtual-ip {ipv4-address | ipv6-address} To return to the default, use the no virtual-ip {ipv4-address | ipv6-address} command. Parameters ipv4-address Enter the IP address of the active management interface in a dotted decimal format (A.B.C.D.).
write Copy the current configuration to either the startup-configuration file or the terminal. Syntax Parameters write {memory compressed| terminal} memory Enter the keyword memory to copy the current running configuration to the startup configuration file. This command is similar to the copy runningconfig startup-config command. compressed Enter the keyword compressed to write the operating configuration to the startup-config file in the compressed mode.
5 802.1X An authentication server must authenticate a client connected to an 802.1X switch port. Until the authentication, only extensible authentication protocol over LAN (EAPOL) traffic is allowed through the port to which a client is connected. After authentication is successful, normal traffic passes through the port. The Dell Networking operating software supports remote authentication dial-in service (RADIUS) and active directory environments using 802.1X Port Authentication.
interface interface Restricts the debugging information to an interface. Defaults Disabled Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Introduced on the C-Series and S-Series. If the host responds to 802.1X with an incorrect login/password, the login fails. The switch attempts to authenticate again until the maximum attempts configured is reached. If the authentication fails after all allowed attempts, the interface moves to the authentication failed VLAN.
dot1x auth-type mab-only To authenticate a device with MAC authentication bypass (MAB), only use the host MAC address. Syntax dot1x auth-type mab-only Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
dot1x guest-vlan Configure a guest VLAN for limited access users or for devices that are not 802.1X capable. Syntax dot1x guest-vlan vlan-id To disable the guest VLAN, use the no dot1x guest-vlan vlan-id command. Parameters vlan-id Enter the VLAN Identifier. The range is from 1 to 4094. Defaults Not configured. Command Modes CONFIGURATION (conf-if-interface-slot/port) Command History This guide is platform-specific.
dot1x host-mode Enable single-host or multi-host authentication. Syntax dot1x host-mode {single-host | multi-host | multi-auth} Parameters single-host Enable single-host authentication. multi-host Enable multi-host authentication. multi-auth Enable multi-supplicant authentication. Defaults single-host Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
Version Description 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x max-supplicants Restrict the number of supplicants that can be authenticated and permitted to access the network through the port. This configuration is only takes effect in Multi-auth mode. Syntax dot1x max-supplicants number Parameters number Enter the number of supplicants that can be authenticated on a single port in Multi-auth mode.
force-unauthorized Enter the keywords force-unauthorized to forcibly de-authorize a port. Defaults none Command Modes Auto Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.
Version Description 8.3.12.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x reauthentication Enable periodic reauthentication of the client. Syntax dot1x reauthentication [interval seconds] To disable periodic reauthentication, use the no dot1x reauthentication command. Parameters interval seconds (Optional) Enter the keyword interval then the interval time, in seconds, after which reauthentication is initiated.
Parameters number Enter the permitted number of re-authentications. The range is from 1 to 10. The default is 2. Defaults 2 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. When you configure the dot1x server-timeout value, take into account the communication medium used to communicate with an authentication server and the number of RADIUS servers configured.
Version Description 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x tx-period Configure the intervals at which EAPOL PDUs the Authenticator PAE transmits. Syntax dot1x tx-period seconds To return to the default, use the no dot1x tx-period command. Parameters seconds Enter the interval time, in seconds, that EAPOL PDUs are transmitted. The range is from 1 to 65535. The default is 30.
mac-address Defaults • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. (Optional) MAC address of an 802.1X-authenticated supplicant. none Command Modes Command History • EXEC • EXEC privilege This guide is platform-specific.
802.1p CoS re-map table for Supplicant: 00:00:00:00:00:10 Dot1p 0 1 2 3 4 5 6 7 Dell# Remapped Dot1p 7 6 5 4 3 2 1 0 show dot1x interface Display the 802.1X configuration of an interface.
Usage Information If you enable 802.1X multi-supplicant authentication on a port, additional 802.1X configuration details (Port Authentication status, Untagged VLAN ID, Authentication PAE state, and Backend state) display for each supplicant, as shown in the following example. Example Dell#show dot1x interface tengigabitethernet 1/32/1 802.
Dell# show dot1x interface gigabitethernet 1/32 mac-address 00:00:00:00:00:11 Supplicant Mac: 0 0 0 0 0 10 Lookup for Mac: 802.
00:00:00:00:00:11 Supplicant Mac: 0 0 0 0 0 10 Lookup for Mac: 802.
6 Access Control Lists (ACL) Access control lists (ACLs) are supported by the Dell Networking OS.
Command History • CONFIGURATION-EXTENDED-ACCESS-LIST • CONFIGURATION-MAC ACCESS LIST-STANDARD • CONFIGURATION-MAC ACCESS LIST-EXTENDED This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
• Command History CONFIGURATION-MAC ACCESS LIST-EXTENDED This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.1.
Defaults Not configured. Command Modes LINE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the ipv4 and ipv6 parameters to the command. Introduced on the S3048-ON and S4048-ON. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Parameters access-list-name (OPTIONAL) Enter the name of a configured access-list, up to 140 characters. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
NOTE: When you specify a single VRF, use the name of the VRF instead of the VRF ID number. Use the VRF ID numbers only when you specify a range of VRFs. Defaults Not enabled. Command Modes INTERFACE/VRF MODE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Defaults Not enabled. Command Modes EXEC Privilege Command History Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. show ip accounting access-list Display the IP access-lists created on the switch and the sequence of filters.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. show ip accounting access-lists Description “Extended IP...” Displays the name of the IP ACL. “seq 5...” Displays the filter. If the keywords count or byte were configured in the filter, the number of packets or bytes the filter processes is displayed at the end of the line.
• bytes — Enter the keyword count to count packets the filter processes. • count — Enter the keyword bytesorder to count bytes the filter processes. • dscp — Enter the keyword dcsp followed by the DCSP value to match to the IP DCSCP values. The range is from 0 to 63. • fragments — Enter the keyword fragments to use ACLs to control packet fragments. • order — Enter the keyword order to specify the QoS order of priority for the ACL entry.
permit — configures a permit filter. ip access-list standard Create a standard IP access list (IP ACL) to filter based on IP address. Syntax ip access-list standard access-list-name To delete an access list, use the no ip access-list standard access-list-name command. Parameters access-list-name Enter a string up to 140 characters long as the ACL name. Defaults All IP access lists contain an implicit “deny any,” that is, if no match occurs, the packet is dropped.
permit To permit packets from a specific source IP address to leave the switch, configure a filter. Syntax permit {source [mask]| any | host ip-address} [no-drop] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no permit {source [mask] | any | host ip-address} command. source Enter the IP address in dotted decimal format of the network from which the packet was sent.
Version Description 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. 6.5.10 Expanded to include the optional QoS order priority for the ACL entry. Usage Information The order option is relevant in the context of the Policy QoS feature only.
Usage Information Version Description 8.2.1.0 Introduced on the E-Series ExaScale (IPv6). 8.1.1.0 Introduced on the E-Series ExaScale (IPv4). 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names were up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series.
Command Modes CONFIGURATION-STANDARD-ACCESS-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T.
NOTE: Also refer to the Commands Common to all ACL Types and Common IP ACL Commands sections. deny Configure a filter that drops IP packets meeting the filter criteria. Syntax deny {ip | ip-protocol-number} {source mask | any | host ip-address} {destination mask | any | host ip-address} [count [byte] | log] [dscp value] [order] [monitor] [fragments] [no-drop] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny icmp {source mask | any | host ip-address} {destination mask | any | host ip-address} command. source Enter the IP address of the network or host from which the packets were sent. mask Enter a network mask in /prefix format (/x) or A.B.C.D. The mask, when specified in A.B.C.D format, may be either contiguous or non-contiguous.
Usage Information Version Description 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. The order option is relevant in the context of the Policy QoS feature only. For more information, refer to the Quality of Service chapter of the Dell Networking OS Configuration Guide. The monitor option is relevant in the context of flow-based monitoring only. For more information, refer to the Port Monitoring chapter.
port port Enter the application layer port number. Enter two port numbers if using the range logical operand. The range is from 0 to 65535. The following list includes some common TCP port numbers: • 23 = Telnet • 20 and 21 = FTP • 25 = SMTP • 169 = SNMP destination Enter the IP address of the network or host to which the packets are sent. mask Enter a network mask in /prefix format (/x) or A.B.C.D. The mask, when specified in A.B.C.D format, may be either contiguous or non-contiguous.
Usage Information Version Description 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. The order option is relevant in the context of the Policy QoS feature only. For more information, refer to the Quality of Service chapter of the Dell Networking OS Configuration Guide. The monitor option is relevant in the context of flow-based monitoring only. For more information, refer to the Port Monitoring chapter.
• Parameters Use the no deny udp {source mask | any | host ip-address} {destination mask | any | host ip-address} command. source Enter the IP address of the network or host from which the packets were sent. mask Enter a network mask in /prefix format (/x) or A.B.C.D. The mask, when specified in A.B.C.D format, may be either contiguous or non-contiguous. any Enter the keyword any to specify that all routes are subject to the filter.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Added the keyword dscp. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for non-contiguous mask and added the monitor option.
Related Commands deny — assigns a filter to deny IP traffic. deny tcp — assigns a filter to deny TCP traffic. ip access-list extended Name (or select) an extended IP access list (IP ACL) based on IP addresses or protocols. Syntax ip access-list extended access-list-name To delete an access list, use the no ip access-list extended access-list-name command. Parameters access-list-name Enter a string up to 140 characters long as the access list name.
permit To pass IP packets meeting the filter criteria, configure a filter. Syntax permit {source mask | any | host ip-address} {destination mask | any | host ip-address} [count [bytes]] [dscp value] [order] [fragments] [no-drop] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {source mask | any | host ip-address} {destination mask | any | host ip-address} command.
Usage Information Version Description 8.3.1.0 Add the DSCP value for ACL matching. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. 6.5.10 Expanded to include the optional QoS order priority for the ACL entry.
• urg: urgent field dscp Enter the keyword dscp to deny a packet based on the DSCP value. The range is from 0 to 63. operator (OPTIONAL) Enter one of the following logical operand: port port • eq = equal to • neq = not equal to • gt = greater than • lt = less than • range = inclusive range of ports (you must specify two ports for the port parameter) Enter the application layer port number. Enter two port numbers if you are using the range logical operand. The range is from 0 to 65535.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Added the keyword dscp. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for non-contiguous mask and added the monitor option. Deprecated the keyword established. 6.5.
permit — assigns a permit filter for IP packets. permit udp — assigns a permit filter for UDP packets. permit udp To pass UDP packets meeting the filter criteria, configure a filter.
Command Modes CONFIGURATION-EXTENDED-ACCESS-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Example An ACL rule with a TCP port lt 1023 uses only one entry in the CAM. Rule# Data Mask From To 1 0000000000000000 1111110000000000 0 #Covered 1023 1024 Total Ports: 1024 Related Commands ip access-list extended — creates an extended ACL. permit — assigns a permit filter for IP packets. permit tcp — assigns a permit filter for TCP packets. resequence access-list Re-assign sequence numbers to entries of an existing access-list.
Usage Information When all sequence numbers are exhausted, this feature permits re-assigning a new sequence number to entries of an existing access-list. seq Assign a sequence number to a deny or permit filter in an extended IP access list while creating the filter.
• 25 = SMTP • 169 = SNMP destination Enter the IP address of the network or host to which the packets are sent. count (OPTIONAL) Enter the keyword count to count packets the filter processes. byte (OPTIONAL) Enter the keyword byte to count bytes the filter processes. log (OPTIONAL, E-Series only) Enter the keyword log to enter ACL matches in the log. Supported on Jumbo-enabled line cards only. dscp (OPTIONAL) Enter the keyword dcsp to match to the IP DCSCP values.
Usage Information Version Description 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. Deprecated the keyword established. 6.5.10 Expanded to include the optional QoS order priority for the ACL entry. The monitor option is relevant in the context of flow-based monitoring only. For more information, refer to Port Monitoring. The order option is relevant in the context of the Policy QoS feature only.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
NOTE: 1. If the MAC ACL is applied on VLAN, none of the VLAN members should have an access list applied for that VLAN. 2. If the MAC ACL is applied on a Physical or Port Channel interface, the VLAN in which this port is associated should not have an access list applied. 3. If the MAC ACL is applied on a VLAN, then that VLAN should not belong to VLAN ACL group. 4. If the MAC ACL is applied on a VLAN ACL group, then none of the VLANs in that group should have an access list applied on it.
in | out • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Identify whether ACL is applied on ingress or egress side. Command Modes EXEC Privilege Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.
• Parameters Use the no deny {any | mac-source-address mac-source-address-mask} command. any Enter the keyword any to specify that all routes are subject to the filter. mac-sourceaddress Enter a MAC address in nn:nn:nn:nn:nn:nn format. mac-sourceaddress-mask (OPTIONAL) Specify which bits in the MAC address must match. If no mask is specified, a mask of 00:00:00:00:00:00 is applied (in other words, the filter allows only MAC addresses that match).
seq — configures a MAC address filter with a specified sequence number. mac access-list standard To configure a standard MAC ACL, name a new or existing MAC access control list (MAC ACL) and enter MAC ACCESS LIST mode. Also refer to the Commands Common to all ACL Types section and the Common MAC Access List Commands section. Syntax mac access-list standard mac-list-name To delete a MAC access list, use the no mac access-list standard mac-list-name command.
permit To forward packets from a specific source MAC address, configure a filter. Syntax permit {any | mac-source-address [mac-source-address-mask]} [count [byte]] | [log] [monitor] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no permit {any | mac-source-address mac-source-address-mask} command. any Enter the keyword any to forward all packets received with a MAC address.
Usage Information Version Description 6.1.1.0 Introduced on the E-Series. When you use the log option, the CP processor logs details about the packets that match. Depending on how many packets match the log entry and at what rate, the CP may become busy as it has to log these packets’ details. NOTE: When you configure the ACL logging and byte counters simultaneously, byte counters may display an incorrect value. Configure packet counters with logging instead.
Command Modes CONFIGURATION-MAC ACCESS LIST-STANDARD Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
deny To drop packets that match the filter criteria, configure a filter. Syntax deny {any | host mac-address | mac-source-address mac-source-address-mask} {any | host mac-address | mac-destination-address mac-destination-addressmask} [ethertype-operator] [count [byte]] [log] [monitor] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number.
Defaults Not configured. Command Modes CONFIGURATION-MAC ACCESS LIST-EXTENDED Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. 8.1.1.
permit To pass packets matching the criteria specified, configure a filter. Syntax permit {any | host mac-address | mac-source-address mac-source-addressmask} {any | host mac-address | mac-destination-address mac-destinationaddress-mask} [ethertype operator] [count [byte]] | [log] [monitor] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number.
NOTE: For more information, refer to the Flow-based Monitoring section in the Port Monitoring chapter of the Dell Networking OS Configuration Guide. Defaults Not configured. Command Modes CONFIGURATION-MAC ACCESS LIST-EXTENDED Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Parameters prefix-name (OPTIONAL) Enter the name of the configured prefix list to clear only counters for that prefix list, up to 140 characters long. Defaults Clears “hit” counters for all prefix lists unless a prefix list is specified. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Version Description 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information Prefix lists redistribute OSPF and RIP routes meeting specific criteria. Related Commands show ip route list — displays IP routes in an IP prefix list. show ip prefix-list summary — displays a summary of the configured prefix lists. seq To a deny or permit filter in a prefix list while configuring the filter, assign a sequence number.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Added the bit mask option. If you do not use the ge or le options, only packets with an exact match to the prefix are filtered. show config Display the current PREFIX-LIST configurations.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.
Example Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. The continue feature allows movement from one route-map entry to a specific route-map entry (the sequence number). If you do not specify the sequence number, the continue feature simply moves to the next sequence number (also known as an implied continue).
Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set as-path — adds information to the BGP AS_PATH attribute. match community To match routes that have a certain COMMUNITY attribute in their BGP path, configure a filter. Syntax match community community-list-name [exact] To delete a community match filter, use the no match community command. Parameters community-listname Enter the name of a configured community list.
Parameters interface Enter the following keywords and slot/port[/subport] or number information: • . • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number.
match ip address To match routes based on IP addresses specified in an access list, configure a filter. Syntax match ip address prefix-list-name To delete a match, use the no match ip address prefix-list-name command. Parameters prefix-list-name Enter the name of configured prefix list, up to 140 characters. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific.
To delete a match, use the no match ip next-hop {prefix-list prefix-list-name} command. Parameters prefix-list prefix-listname Enter the keywords prefix-list and then enter the name of configured prefix list, up 10 140 characters. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters prefix-list prefix-listname Enter the keywords prefix-list and then enter the name of configured prefix list, up to 140 characters. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.
Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. pre-6.1.1.0 Introduced on the E-Series. match route-type To match routes based on the how the route is defined, configure a filter.
Related Commands Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. match interface — redistributes routes that match the next-hop interface. match ip address — redistributes routes that match an IP address. match ip next-hop — redistributes routes that match the next-hop IP address. match ip route-source — redistributes routes that match routes advertised by other routers.
Related Commands match interface — redistributes routes that match the next-hop interface. match ip address — redistributes routes that match an IP address. match ip next-hop — redistributes routes that match the next-hop IP address. match ip route-source — redistributes routes that match routes advertised by other routers. match metric — redistributes routes that match a specific metric. match route-type — redistributes routes that match a route type.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information Use caution when you delete route maps because if you do not specify a sequence number, all route maps with the same map-name are deleted when you use the no route-map map-name command. Example Dell(conf)#route-map dempsey Dell(config-route-map)# Related Commands show config — displays the current configuration.
Related Commands match as-path — redistributes routes that match an AS-PATH attribute. set automatic-tag To automatically compute the tag value of the route, configure a filter. Syntax set automatic-tag To return to the default, enter no set automatic-tag. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
All routes with the NO_EXPORT_SUBCONFED (0xFFFFFF03) community attribute must not be advertised to external BGP peers. no-advertise Enter the keywords no-advertise to drop all routes containing the well-known community attribute of NO_ADVERTISE. All routes with the NO_ADVERTISE (0xFFFFFF02) community attribute must not be advertised to other BGP peers. no-export Enter the keywords no-export to drop all routes containing the well-known community attribute of NO_EXPORT.
Parameters backbone Enter the keyword backbone to redistribute matched routes to the OSPF backbone area (area 0.0.0.0). level-1 Enter the keyword level-1 to redistribute matched routes to IS-IS Level 1. level-1-2 Enter the keyword level-1-2 to redistribute matched routes to IS-IS Level 1 and Level 2. level-2 Enter the keyword level-2 to redistribute matched routes to IS-IS Level 2. stub-area Enter the keyword stub to redistributed matched routes to OSPF stub areas. Defaults Not configured.
Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set automatic-tag — computes the tag value of the route. set level — specifies the OSPF area for route redistribution.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. 8.3.1.0 Implemented the keyword internal. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set automatic-tag — computes the tag value of the route. set level — specifies the OSPF area for route redistribution. set metric — specifies the metric value assigned to redistributed routes.
Usage Information If you configure the set next-hop command, its configuration takes precedence over the neighbor next-hop-self command in the ROUTER BGP mode. If you configure the set next-hop command with the interface’s IP address (either Loopback or physical), the software declares the route unreachable. Related Commands match ip next-hop — redistributes routes that match the next-hop IP address. set origin To manipulate the BGP ORIGIN attribute, configure a filter.
To delete a setting, use the no set tag command. Parameters tag-value Enter a number as the tag. The range is from zero (0) to 4294967295. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.
Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Example Dell(conf-nprefixl)#show config ! ip prefix-list PL_OSPF_to_RIP seq 5 permit 1.1.1.0/24 seq 10 deny 2.1.0.0/16 ge 23 seq 25 permit 192.0.0.0 bitmask 192.0.0.0 show route-map Display the current route map configurations. Syntax show route-map [map-name] Parameters Command Modes Command History map-name • EXEC • EXEC Privilege (OPTIONAL) Enter the name of a configured route map, up to 140 characters. This guide is platform-specific.
deny (for Standard IP ACLs) To drop packets with a certain IP address, configure a filter. Syntax deny {source | any | host {ip-address}}[count [byte]] [dscp value] [order] [fragments] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {source [mask] | any | host ip-address} command.
both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface. This feature is particularly useful when looking for malicious traffic. It is available for Layer 2 and Layer 3 ingress and egress traffic. You may specify traffic using standard or extended access-lists. This mechanism copies all incoming or outgoing packets on one port and forwards (mirrors) them to another port.
Usage Information Version Description 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled.
To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny tcp {source mask | any | host ip-address} {destination mask | any | host ip-address} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG). Related Commands deny — assigns a filter to deny IP traffic. deny udp — assigns a filter to deny UDP traffic. deny ether-type (for Extended MAC ACLs) Configure an egress filter that drops specified types of Ethernet packets on egress ACL supported line cards. (For more information, refer to your line card documentation).
Usage Information Version Description 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information CONFIGURATION-MAC ACCESS LIST-STANDARD Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms.
• Parameters Defaults Use the no deny {any | host mac-address | mac-source-address mac-sourceaddress-mask} {any | host mac-address | mac-destination-address macdestination-address-mask} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated.
Related Commands permit — configures a MAC address filter to pass packets. seq — configures a MAC address filter with a specified sequence number. permit (for Standard IP ACLs) To permit packets from a specific source IP address to leave the switch, configure a filter.
If ACL logging is stopped because the configured threshold is exceeded, it is re-enabled after the logging interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs. You can configure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces.
Command Modes Command History Usage Information CONFIGURATION-EXTENDED-ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
the generation of ACL logs is terminated. with the seq, permit, or deny commands. The threshold range is from 1 to 100. Defaults interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The interval range is from 1 to 10 minutes. monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface.
To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no permit icmp {source mask | any | host ip-address} {destination mask | any | host ip-address} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
permit udp (for Extended IP ACLs) To pass UDP packets meeting the filter criteria, configure a filter. Syntax permit udp {source mask | any | host ip-address} [operator port [port]] {destination mask | any | host ip-address} [dscp] [operator port [port]] [count [byte]] [order] [fragments] [log [interval minutes] [threshold-inmsgs [count]][monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added the support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added the support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
Defaults threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated with the seq, permit, or deny commands. The threshold range is from 1 to 100. interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The interval range is from 1 to 10 minutes.
seq (for Standard MAC ACLs) To a deny or permit filter in a MAC access list while creating the filter, assign a sequence number. Syntax seq sequence-number {deny | permit} {any | mac-source-address [mac-sourceaddress-mask]} [count [byte]] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, use the no seq sequence-number command. Parameters Defaults log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
standard or extended access-lists. This mechanism copies all incoming or outgoing packets on one port and forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG). Related Commands deny — configures a filter to drop packets. permit — configures a filter to forward packets. permit tcp (for Extended IP ACLs) To pass TCP packets meeting the filter criteria, configure a filter.
Usage Information When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero. If ACL logging was stopped previously because the configured threshold is exceeded, it is re-enabled for this new interval.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is 5 minutes. By default, flow-based monitoring is not enabled.
address mac-address-mask | any} [count [byte]] [order] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, use the no seq sequence-number command. Parameters Defaults log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated.
forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG). seq (for IP ACLs) Assign a sequence number to a deny or permit filter in an extended IP access list while creating the filter.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Usage Information Version Description 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information ACCESS-LIST Version Description 9.7(0.
Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no permit tcp {source address mask | any | host ipv6-address} {destination address | any | host ipv6-address} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
Related Commands permit – assigns a permit filter for IP packets. permit icmp (for IPv6 ACLs) To allow all or specific internet control message protocol (ICMP) messages, configure a filter.
If ACL logging is stopped because the configured threshold is exceeded, it is re-enabled after the logging interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs. You can configure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces.
Command History Usage Information Version Description 9.8(0.0) Added the no-drop parameter. 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
Defaults interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The threshold range is from 1 to 10 minutes. monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
deny arp (for Extended MAC ACLs) Configure an egress filter that drops ARP packets on egress ACL supported line cards. (For more information, refer to your line card documentation).
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Usage Information Version Description 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is 5 minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information ACCESS-LIST Version Description 9.7(0.
Parameters Defaults log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated. with the seq, permit, or deny commands. The threshold range is from 1 to 100.
7 Bidirectional Forwarding Detection (BFD) Bidirectional forwarding detection (BFD) is a detection protocol that provides fast forwarding path failure detection.
ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Introduced BFD for VRRP and OSPFv3 on Z9000, S4810, and S4820T. 9.0.0.0 Introduced BFD for BGP on the Z9000. 8.3.19.
To disable BFD for all neighbors configured through static routes, use the no ip route bfd [interval interval min_rx min_rx multiplier value role {active | passive}] command. Parameters interval milliseconds (OPTIONAL) Enter the keywords interval to specify non-default BFD session parameters beginning with the transmission interval. The range is from 50 to 1000. The default is 100.
peer-group-name Enter the name of the peer group that you want to explicitly enable for BFD sessions. Defaults none Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Defaults none Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.
8 Boot Command Line Interface To access this BOOT_USER mode, first boot your Dell Networking platform. When you see the “Press ESC to stop auto-boot”, press the ESC key to log into BCLI You enter BOOT_USER mode immediately, as indicated by the BOOT_USER# prompt. NOTE: All commands in this chapter are in Boot_User mode. These commands are supported on the Dell Networking platform. You cannot use the Tab key to complete commands in this mode.
Note: You must set the IP address of the designated download port before you execute this command. Otherwise, an second statement message alerts you that the configuration cannot proceed. shows the first field after you enter boot change primary. At this point: Example • Press Enter to accept the information already configured, or • Change that information. To do so, press the . (period) key and enter new information. After you enter the information, press Enter.
boot show net config retries Show the number of retries for network boot configuration failure. Syntax boot show net config retries Command Modes BOOT_USER Command History Example Version 9.0.2.0 Introduced on the S6000. BOOT_USER #boot show net config retries Number of Network Boot Config Retries is : 0 BOOT_USER # boot write net config retries Set the number of retries for network boot configuration failure.
default Defaults None Command Modes BOOT_USER Command History Usage Information Version 9.0.2.0 Enter the keyword default to configure boot parameters used if the secondary operating system boot parameter selection is not available. You can configure this option to any of the available type, for example flash/usb/ftp/tftp. Introduced on the S6000. This command reverses changes made with the boot change command.
Parameters Command Modes Command History ip-address Enter the IP address of the gateway router in dotted decimal format (A.B.C.D). BOOT_USER Version 9.0.2.0 Introduced on the S6000. Usage Information Use the show default-gateway command to view the current default gateway. Related Commands show_default-gateway— Change the primary, secondary, or default boot image configuration. etheraddr Assign the management port MAC address.
Usage Information When you enter the reload command and the system reboots, you will not be prompted for a password to enter the EXEC Privilege mode (normally you are required to enter the enable command). If your console or Telnet session expires after you used the ignore enable-password command, you are prompted for an enable password when you re-establish the session Related Commands reload — Exit from this mode and reload FTOS.
show_interface_mangement_ethernet— Display the IP address configured for the Management interface. NVRAM erase Erase all NVRAM contents alone. Syntax Parameters Command Modes Command History nvram erase mac-address Enter a MAC address in standard format. BOOT_ADMIN Version 9.0.2.0 Introduced on the S6000. Usage Information Use this command to assign a MAC address if FTOS cannot find a default MAC address.
Parameters serial console [unit] [baud] Enter the keyword to set the serial port baud rate. The supported values for serial console: • Unit - 0 • Baud rate -9600,115200 No defaults. Command Modes Command History Example Serial BOOT_USER Version 9.0.2.0 Introduced on the S6000. BOOT_USER # serial console 0 9600 BOOT_USER # BOOT_USER # show bootvar Display boot configuration information. Syntax show bootvar Command Modes BOOT_USER Command History Example Version 9.0.2.
file name : PS-SI-9-0-0-566.bin Management Etherenet IP address : 10.16.133.17 Mask : 255.255.0.0 Server IP address : 10.16.1.200 Default Gateway IP address : 10.16.1.254 BOOT_USER # Related Commands boot_change— Change the primary, secondary, or default boot image configuration. boot_zero — Erase the configured primary, secondary, or default boot image parameters. show default-gateway Display the IP address configured for the default gateway.
Example BOOT_USER # show interfaces management ethernet Management ethernet IP address: 10.16.133.17/24 BOOT_ADMIN # On the S6000, the output of this command includes the MAC address and port number of the assigned management port. Example BOOT_ADMIN # show int man eth Management ethernet IP address: 10.16.132.4/16 BOOT_ADMIN # Related Commands interface_management_ethernet_ip_address — Assign an IP address to the Management Ethernet interface.
settimeout Enter the keyword set timeout to set timeout. NOTE: By default, watchdog is disabled. Command Modes Command History Example BOOT_ADMIN Version 9.0.2.0 Introduced on the S6000.
9 Border Gateway Protocol BGP is an external gateway protocol that transmits interdomain routing information within and between autonomous systems (AS). BGP version 4 (BGPv4) supports classless inter-domain routing (CIDR) and the aggregation of routes and AS paths. Basically, two routers (called neighbors or peers) exchange information including full routing tables and periodically sent messages to update those routing tables.
NOTE: Use this attribute to start a BGP instance corresponding to either a specific address family in a default VRF or an IPv4 address family in a nondefault VRF. ipv6 unicast Enter the keyword ipv6 followed by the keyword unicast to enable BGPv6 mode. vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to install the IPv6 route in that VRF. NOTE: It will not be possible to enable VRF mode for IPv6 unicast without configuring the corresponding IPv4 unicast mode for the same VRF.
Defaults attribute-map mapname (OPTIONAL) Enter the keywords attribute-map then the name of a configured route map to modify attributes of the aggregate, excluding AS_PATH and NEXT_HOP attributes. summary-only (OPTIONAL) Enter the keyword summary-only to advertise only the aggregate address. Specific routes are not advertised. suppress-map mapname (OPTIONAL) Enter the keywords suppress-map then the name of a configured route map to identify which more-specific routes in the aggregate are suppressed.
The attribute-map corresponding to an aggregate address is applied during the outbound update creation time; hence the value set in that attribute-map will not be shown in the output of the show ip bgp aggregate route command. bgp add-path Allow the advertisement of multiple paths for the same address prefix without the new paths replacing any previous ones.
Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
Usage Information Before enabling this feature, enable the enable bgp four-octet-as-supportcommand. If you disable the four-octect-support command after using dot or dot+ format, the AS numbers revert to asplain text. When you apply an asnotation, it is reflected in the running-configuration. If you change the notation type, the running-config updates dynamically and the new notation shows.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. If you enable this command, use the clear ip bgp * command to recompute the best path. bgp bestpath as-path multipath-relax Include prefixes received from different AS paths during multipath calculation.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Usage Information The MED is a 4-byte unsigned integer value and the default behavior is to assume a missing MED as 4294967295. This command causes a missing MED to be treated as 0. During path selection, paths with a lower MED are preferred over paths with a higher MED. bgp bestpath router-id ignore Do not compare router-id information for external paths during best path selection. Syntax bgp bestpath router-id ignore To return to the default selection, use the no bgp bestpath router-id ignore command.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Usage Information Route reflection to clients is not necessary if all client routers are fully meshed. Related Commands bgp cluster-id — assigns an ID to a BGP cluster with two or more route reflectors. neighbor route-reflector-client — configures a route reflector and clients.
cluster-id command. Without a cluster ID, the route reflector cannot recognize route updates from the other route reflectors within the cluster. The default format for displaying the cluster-id is dotted decimal, but if you enter the cluster-id as an integer, it is displayed as an integer. This command automatically restarts the BGP instance for the configuration to take effect. Related Commands bgp client-to-client reflection — enables route reflection between the route reflector and clients.
The autonomous systems configured in this command are visible to the EBGP neighbors. Each autonomous system is fully meshed and contains a few connections to other autonomous systems. The next hop, MED, and local preference information is preserved throughout the confederation. Dell Networking OS accepts confederation EBGP peers without a LOCAL_PREF attribute. The software sends AS_CONFED_SET and accepts AS_CONFED_SET and AS_CONF_SEQ.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. Added support for the 4-byte format. All the routers in the Confederation must be 4 byte or 2 byte identified routers. You cannot mix them. The autonomous systems configured in this command are visible to the EBGP neighbors. Each autonomous system is fully meshed and contains a few connections to other autonomous systems.
Command Modes Command History • ROUTER BGP • ROUTER BGP-address-family This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Usage Information All routers apply the bgp default local-preference command setting within the AS. To set the local preference for a specific route, use the set local-preference command in ROUTE-MAP mode.
bgp enforce-first-as Disable (or enable) enforce-first-as check for updates received from EBGP peers. Syntax bgp enforce-first-as To turn off the default, use the no bgp enforce-first-as command. Defaults Enabled Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
To disable fast external fallover, use the no bgp fast-external-fallover command. Defaults Enabled Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Routers supporting 4-byte ASNs advertise that function in the OPEN message. The behavior of a 4-byte router is slightly different depending on whether it is speaking to a 2-byte router or a 4-byte router. When creating Confederations, all the routers in the Confederation must be 4 byte or 2 byte identified routers. You cannot mix them.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. This feature is advertised to BGP neighbors through a capability advertisement. In Receiver Only mode, BGP saves the advertised routes of peers that support this capability when they restart. BGP graceful restart is active only when the neighbor becomes established. Otherwise it is disabled.
When you change the path selection from Deterministic to Non-Deterministic, the path selection for the existing paths remains Deterministic until you enter the clear ip bgp command to clear existing paths. bgp recursive-bgp-next-hop Enable next-hop resolution through other routes learned by BGP. Syntax bgp recursive-bgp-next-hop To disable next-hop resolution, use the no bgp recursive-bgp-next-hop command. Defaults Enabled Command Modes ROUTER BGP Command History This guide is platform-specific.
Command Modes ROUTER BGP (conf-router_bgp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
bgp router-id Assign a user-given ID to a BGP router. Syntax bgp router-id ip-address To delete a user-assigned IP address, use the no bgp router-id command. Parameters ip-address Enter an IP address in dotted decimal format to reset only that BGP neighbor. Defaults The router ID is the highest IP address of the Loopback interface or, if no Loopback interfaces are configured, the highest IP address of a physical interface on the router.
NOTE: Use this attribute to clear a BGP instance corresponding to either a specific address family in a default VRF or an IPv4 address family in a a non-default VRF. * Enter an asterisk ( * ) to reset all BGP sessions. <1-4294967295> Enter <1-4294967295> to clear peers with the AS number. <0.1-65535.65535> Enter <0.1-65535.65535> to clear peers with the AS number in dot format. A.B.C.D Enter the BGP neighbor address in the A.B.C.D format to clear.
Related Commands bgp recursive-bgp-next-hop — disables next-hop resolution through other routes learned by the BGP. clear ip bgp dampening Clear information on route dampening and return the suppressed route to the Active state.
The clear ip bgp dampening command does not clear the history paths. clear ip bgp flap-statistics Clear BGP flap statistics, which includes number of flaps and the time of the last flap.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
out Enter the keyword out to re-configure soft outbound updates. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000.
ipv6 Enter the ipv6 IP address to view the IPV6 route information. keepalives Enter the keyword keepalives to view BGP keepalives. notifications Enter the keyword notifications to view BGP notifications. soft-reconfiguration Enter the keywords soft-reconfiguration to view only information on inbound BGP soft reconfiguration. updates Enter the keyword updates to view BGP updates. Command Modes EXEC Privilege Command History This guide is platform-specific.
Parameters vrf vrf-name Enter the keyword vrf followed by the name of the VRF to view information on dampened routes corresponding to that VRF. ipv4 multicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword multicast to view dampened-route information related only to ipv4 multicast routes. ipv4 unicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword multicast to view dampened-route information related only to ipv4 unicast routes.
in (OPTIONAL) Enter the keyword in to view only events on inbound BGP messages. out (OPTIONAL) Enter the keyword out to view only events on outbound BGP messages. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. To remove all configured debug commands for BGP, enter the no debug ip bgp command. debug ip bgp soft-reconfiguration Enable soft-reconfiguration debug. Syntax debug ip bgp [vrf vrf-name] [A.B.C.
Usage Information Version Description 7.2.1.0 Introduced. This command turns on BGP soft-reconfiguration inbound debugging. If no neighbor is specified, debug turns on for all neighbors. debug ip bgp updates Allows you to view information about BGP updates. Syntax debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-groupname] updates [in | out | prefix-list prefix-list-name] To disable debugging, use the no debug ip bgp [vrf vrf-name] [A.B.C.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. To remove all configured debug commands for BGP, enter the no debug ip bgp command. default-metric Allows you to change the metric of redistributed routes to locally originated routes. Use this command with the redistribute command. Syntax default-metric number To return to the default setting, use the no default-metric command.
deny bandwidth Enables you to specify link band width extended-community attribute as the matching criteria to deny incoming or outgoing traffic. Syntax deny bandwidth To disable this setting, enter the no deny bandwidth command. Parameters bandwidth Enter the keyword bandwidth to specify extended-community attribute as the matching criteria for denying traffic. The range is from 0 to 102400.
Related Commands Version Description pre-7.7.1.0 Introduced. router bgp — enters ROUTER mode on the switch. maximum-paths Configure the maximum number of parallel routes (multipath support) BGP supports. Syntax maximum-paths {ebgp | ibgp} number To return to the default values, enter the no maximum-paths command. Parameters ebgp Enter the keyword ebgp to enable multipath support for External BGP routes. ibgp Enter the keyword ibgp to enable multipath support for Internal BGP routes.
To disable, use the no neighbor [ip-address | peer-group-name] activate command. Parameters ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. peer-group-name (OPTIONAL) Enter the name of the peer group. activate Enter the keyword activate to enable the neighbor/peer group in the new AFI/ SAFI. Defaults Disabled Command Modes CONFIGURATION-ROUTER-BGP-ADDRESS FAMILY Command History This guide is platform-specific.
path-count Enter the number paths supported. The range is from 2 to 64. Defaults none Command Modes CONFIGURATION-ROUTER-BGP-ADDRESS FAMILY Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. neighbor advertisement-start To send BGP routing updates, set the minimum interval before starting.
neighbor allowas-in Set the number of times an AS number can occur in the AS path. Syntax neighbor {ip-address | peer-group-name} allowas-in number To return to the default value, use the no neighbor {ip-address | peer-group-name} allowas-in command. Parameters ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group to set the advertisement interval for all routers in the peer group.
Parameters ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group to set the default route of all routers in that peer group. route-map mapname (OPTIONAL) Enter the keyword route-map then the name of a configured route map. Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific.
neighbor description Assign a character string describing the neighbor or group of neighbors (peer group). Syntax neighbor {ip-address | peer-group-name} description text To delete a description, use the no neighbor {ip-address | peer-group-name} description command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group. text Enter a continuous text string up to 80 characters. Defaults Not configured.
prefix-list-name Enter the name of an established prefix list. If the prefix list is not configured, the default is permit (to allow all routes). in Enter the keyword in to distribute only inbound traffic. out Enter the keyword out to distribute only outbound traffic. Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Version Description 7.4.1.0 Introduced Usage Information When you enable failover, BGP keeps track of IP or IPv6 ability to reach the peer remote address and the peer local address. Whenever either address becomes unreachable (for example, no active route exists in the routing table for the peer IP or IPv6 destination/local address), BGP brings down the session with the peer. Related Commands show ip bgp neighbors — displays information on the BGP neighbors.
Usage Information If a local-as is configured, BGP does not allow for the configuration of BGP confederation. Similarly, if BGP confederation is configured, then BGP does not allow the configuration of local-as. This command automatically restarts the neighbor session for the configuration to take effect. Related Commands bgp four-octet-as-support — enables 4-byte support for the BGP process. neighbor maximum-prefix Control the number of network prefixes received.
Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Usage Information If you configure the neighbor maximum-prefix command and the neighbor receives more prefixes than the neighbor maximum-prefix command configuration allows, the neighbor goes down and the show ip bgp summary command displays (prfxd) in the State/PfxRcd column for that neighbor.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. This command automatically restarts the neighbor session for the configuration to take effect. Configure the same password on both BGP peers or a connection does not occur. When you configure MD5 authentication between two BGP peers, each segment of the TCP connection between them is verified and the MD5 digest is checked on every segment sent on the TCP connection.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added the dmzlink-bw parameter. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
To delete a peer group, use the no neighbor peer-group-name peer-group command. Parameters peer-group-name Enter a text string up to 16 characters long as the name of the peer group. Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced the limit keyword on the S4810. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Added 4-byte support. To accept 4-byte formats before entering a 4 byte AS Number, configure your system.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Added 4-byte support. Applies to EBGP neighbors only. Configure your system to accept 4-byte formats before entering a 4 byte AS Number. If the AS-PATH contains both public and private AS number or contains AS numbers of an EBGP neighbor, the private AS numbers are not removed.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. When you apply a route map to outbound routes, only routes that match at least one section of the route map are permitted.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. A route reflector reflects routes to the neighbors assigned to the cluster. Neighbors in the cluster do not need not to be fully meshed. By default, when you use no route reflector, the internal BGP (IBGP) speakers in the network must be fully meshed. The first time you enter this command, the router configures as a route reflector and the specified BGP neighbors configure as clients in the route-reflector cluster.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. To configure a COMMUNITY attribute, use the set community command in ROUTE-MAP mode. In order that settings corresponding to the neighbor send-community command take effect, you must execute the clear ip bgp command immediately after you execute the neighbor sendcommunity command.
The neighbor shutdown command terminates all BGP sessions on the BGP neighbor or BGP peer group. Use this command with caution as it terminates the specified BGP sessions. When a neighbor or peer group is shut down, use the show ip bgp summary command to confirm its status. Related Commands show ip bgp summary — displays the current BGP configuration. show ip bgp neighbors — displays the current BGP neighbors. neighbor soft-reconfiguration inbound Enable soft-reconfiguration for BGP.
CAUTION: Inbound update storage is a memory-intensive operation. The entire BGP update database from the neighbor is stored in memory regardless of the inbound policy results applied on the neighbor. NOTE: This command is supported in BGP Router Configuration mode for IPv4 Unicast address only. Related Commands show ip bgp neighbors — displays routes received by a neighbor. neighbor timers Set keepalive and hold time timers for a BGP neighbor or a peer group.
Usage Information Timer values configured with the neighbor timers command override the timer values configured with any other command. When two neighbors, configured with different keepalive and holdtime values, negotiate for new values, the resulting values are as follows: • the lower of the holdtime value is the new holdtime value, and • whichever is the lower value; one-third of the new holdtime value, or the configured keepalive value, is the new keepalive value.
neighbor weight Assign a weight to the neighbor connection, which is used to determine the best path. Syntax neighbor {ip-address | peer-group-name} weight weight To remove a weight value, use the no neighbor {ip-address | peer-group-name} weight command. Parameters ip-address Enter the IP address of the peer router in dotted decimal format. peer-group-name Enter the name of the peer group to disable all routers within the peer group. weight Enter a number as the weight.
To remove a network, use the no network ip-address mask [route-map map-name] command. Parameters ip-address Enter an IP address in dotted decimal format of the network. mask Enter the mask of the IP address in the slash prefix length format (for example, / 24). The mask appears in command outputs in dotted decimal format (A.B.C.D). route-map mapname (OPTIONAL) Enter the keyword route-map then the name of an established route map.
When a combination of locally originated and peer originated routes occurs, both these routes will exist in the RTM. However, only the best route is kept active in the RTM and the remaining route is rendered inactive. It is possible to keep only one locally originated route in the BGP database. Network command has preference over the re-distributed routes. When the locally originated route is no longer present in the database the other route is automatically installed.
permit bandwidth Enables you to specify link band width extended-community attribute as the matching criteria to permit incoming or outgoing traffic. Syntax permit bandwidth To disable this setting, enter the no permit bandwidth command. Parameters bandwidth Enter the keyword bandwidth to specify extended-community attribute as the matching criteria for permitting traffic. The range is from 0 to 102400.
Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Parameters process-id Enter the number of the OSPF process. The range is from 1 to 65535. match external {1 | 2} (OPTIONAL) Enter the keywords match external to redistribute OSPF external routes. You can specify 1 or 2 to redistribute those routes only. match internal (OPTIONAL) Enter the keywords match internal to redistribute OSPF internal routes only. route-map mapname (OPTIONAL) Enter the keywords route-map then the name of a configured route map. Defaults Not configured.
Parameters as-number Enter the AS number. The range is from 1 to 65535 (2 byte), from 1 to 4294967295 (4 byte), or from 0.1 to 65535.65535 (dotted format). Defaults Not enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.
Usage Information A new policy command is introduced in order to attach the Link Bandwidth extended community only to the prefixes that are received from a neighbor that satisfy the desired conditions. This command is relevant for both inbound as well as outbound policy handling (for received prefixes). Also, there is no change to the set of supported conditions or filters. During configuration, the bandwidth is specified in Mbps, not in bytes/second.
Outgoing packet capture enabled for BGP neighbor 20.20.20.2 Available buffer size 40958758, 27 packet(s) captured using 562 bytes PDU[1] : len 41, captured 00:34:52 ago ffffffff ffffffff ffffffff ffffffff 00290104 000100b4 14141401 0c020a01 04000100 01020080 00000000 PDU[2] : len 19, captured 00:34:51 ago ffffffff ffffffff ffffffff ffffffff 00130400 PDU[3] : len 19, captured 00:34:50 ago ffffffff ffffffff ffffffff ffffffff 00130400 [. . .] Dell# show config View the current ROUTER BGP configuration.
Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to view ipv4– unicast route information corresponding to that VRF. ipv4 unicast (OPTIONAL) Enter the keywords ipv4 unicast to view information only related to ipv4 unicast routes. network (OPTIONAL) Enter the network address (in dotted decimal format) of the BGP network to view information only on that network.
Field Description Weight Displays the route’s weight. Path Lists all the ASs the route passed through to reach the destination network. The show ip bgp command displays the dmzlink-dw details only if dmzlink-bw is enabled using the bgp dmzlink-dw command. Example Dell#show ip bgp BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.
Command Modes Command History ipv6 unicast (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to view information related to only to the ipv6 unicast routes. cluster-id (OPTIONAL) Enter the cluster id in dotted decimal format. The range is 1 — 4294967295. • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Dell#show ip bgp cluster-list 4.4.4.4 BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.6 Status codes: s suppressed, S stale, d dampened, h history, * valid, > best Path source: I - internal, a - aggregate, c - confed-external, r redistributed n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete Network *>I 55.0.0.0/24 500 600 i *>I 66.0.0.0/24 *>I 77.0.0.0/24 Dell# Next Hop 172.16.0.2 Metric 172.16.0.2 172.16.0.
no-export Enter the keywords no-export to view all routes containing the well-known community attribute of NO_EXPORT. All routes with the NO_EXPORT (0xFFFFFF01) community attribute must not be advertised outside a BGP confederation boundary. Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
aa:nn | Community number in aa:nn format Pipe through a command Dell#show ip bgp community BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.5 Status codes: s suppressed, S stale, d dampened, h history, * valid, > best Path source: I - internal, a - aggregate, c - confed-external, r redistributed n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete *> *> Network 55.0.0.0/24 66.0.0.0/24 Next Hop 172.16.0.2 172.16.0.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series.
Origin IGP, Metric external 4294967295 (Default), LocalPref Communities : 200:1 1000:1 100, Weight 0, 3000:1 show ip bgp dampened-paths View BGP routes that are dampened (non-active). Syntax Parameters Command Modes Command History show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] dampened-paths vrf vrf-name (OPTIONAL) Enter the keywords vrf and then the name of the VRF to view routes that are affected by a specific community list corresponding to that VRF.
The history paths that the show ip bgp command displays contain only the prefix and the next-hop information. The next-hop information shows the ip address of the neighbor. It does not show the actual next-hop details. The following describes the show ip bgp damp command shown in the following example. Example Field Description Network Displays the network ID to which the route is dampened. From Displays the IP address of the neighbor advertising the dampened route.
Example Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Introduced.
NdAFWPtrP 0 NdAFWLen 0 : NdAfNH : NdAFRedRttP 0x41a0d400 : NdRecCtxAdd 1101110868 NdRedCtxAddrLen 255 : NdAfRedMkrP 0x41a19e88 : AFAggRttP 0x41a0d600 : AfAggCtxAddr 1101111028 : AfAggrCtxAddrLen 255 AfNumAggrPfx 0 : AfNumAggrASSet 0 : AfNumSuppmap 0 : AfNumAggrValidPfx 0 : AfMPathRttP 0x41a0d700 MpathCtxAddr 1101111140 : MpathCtxAddrlen 255 : AfEorSet 0x41a19f98 : NumDfrdPfx 0 AfActPeerHd 0x41a1a3a4 : AfExtDist 1101112312 : AfIntDist 200 : AfLocDist 200 AfNumRRc 0 : AfRR 0 : AfNetRttP 0x41a0d300 : AfNetCtxA
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. To view the total number of COMMUNITY attributes found, use the show ip bgp summary command. The text line above the route table states the number of COMMUNITY attributes found.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.
Path source: I - internal, a - aggregate, c - confed-external, r redistributed n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete *> 400 *> 500 Network 55.0.0.0/24 500 600 i 66.0.0.0/24 i Next Hop 172.16.0.2 Metric LocPrf Weight Path 0 200 172.16.0.2 0 200 show ip bgp flap-statistics View flap statistics on BGP routes.
• Command Modes Command History • EXEC • EXEC Privilege $ = (dollar sign) the end of the output string. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.
00:00:00 200 i Dell#*>n 66.66.77.77/32 0.0.0.0 0 32768 i show ip bgp inconsistent-as View routes with inconsistent originating autonomous system (AS) numbers; that is, prefixes that are announced from the same neighbor AS but with a different AS-Path.
Status codes: s suppressed, d damped, h history, * valid, > best Path source: I - internal, c - confed-external, r - redistributed, n network Origin codes: i - IGP, e - EGP, ? - incomplete Network Next * 3.0.0.0/8 * * *> *> 3.18.135.0/24 * * * *> 4.0.0.0/8 * * * * 6.0.0.0/20 * *> * * 9.2.0.0/16 * --More-- Hop Metric LocPrf Weight Path 63.114.8.33 0 18508 209 63.114.8.34 0 18508 209 63.114.8.60 0 18508 209 63.114.8.33 0 18508 701 63.114.8.60 0 18508 209 63.114.8.34 0 18508 209 63.114.8.33 0 18508 701 63.
NOTE: You can use this attribute to view information exchanged by BGP neighbors that correspond to either a default or a non-default VRF. ipv4 multicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword multicast to view information related only to ipv4 multicast routes. ipv4 unicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword unicast to view information related only to ipv4 unicast routes.
Usage Information Version Description 8.3.8.0 Added the add-path option to the S4810. Output on the S4810 shows the ADDPATH parameters. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Added the detail option. Output now displays the default MED value. 7.2.1.0 Added the received and denied route options. 6.3.10 The output is changed to display the total number of advertised prefixes.
Example The Lines Beginning with: Description (list of inbound and outbound policies) Displays the policy commands configured and the names of the Route map, ASPATH ACL, or Prefix list configured for the policy. For address family: Displays the IPv4 Unicast as the address family. BGP table version Displays which version of the primary BGP routing table the router and the neighbor are using.
Prefixes accepted 2, withdrawn 15 by peer, martian prefixes ignored 0 Prefixes advertised 0, denied 0, withdrawn 0 from peer Connections established 1; dropped 0 Last reset never Local host: 172.16.0.1, Local port: 58145 Foreign host: 172.16.0.2, Foreign port: 179 Dell# Related Commands show ip bgp — views the current BGP routing table. show ip bgp next-hop View all next hops (using learned routes only) with current reachability and flap status.
Example Field Description Time Elapsed Displays the time elapsed since the next hop was learned. If the route is down, this field displays time elapsed since the route went down. Dell# show ip bgp next-hop Next-hop Resolved 172.16.0.2 YES Dell# show ip bgp paths View all the BGP path attributes in the BGP database.
Usage Information Example Version Description 9.4(0.0) Added support for VRF for the S4810, S4820T, and S6000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. The following describes the show ip bgp path command shown in the following example. Field Description Total Displays the total number of BGP path attributes.
The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series.
Command Modes Command History peer-group-name (OPTIONAL) Enter the name of a peer group to view information about that peer group only. detail (OPTIONAL) Enter the keyword detail to view detailed status information of the peers in that peer group. summary (OPTIONAL) Enter the keyword summary to view status information of the peers in that peer group. The output is the same as that found in the show ip bgp summary command. • EXEC • EXEC Privilege This guide is platform-specific.
BGP version 4 Minimum time between advertisement runs is 30 seconds For address family: IPv4 Unicast BGP neighbor is port0, peer-group external Update packing has 4_OCTET_AS support enabled Number of peers in this group 1 Maximum limit on the accepted connections 256 Peer-group members (* - outbound optimized): 172.16.0.2 Dell# Related Commands neighbor peer-group (assigning peers) — assigns a peer to a peer-group. neighbor peer-group (creating group) — creates a peer group.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to view the status of all BGP connections corresponding to that VRF. ipv4 multicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword multicast to view information related only to ipv4 multicast routes. ipv4 unicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword unicast to view information related only to ipv4 unicast routes.
Field Description BGP table version Displays the BGP table version and the main routing table version. network entries Displays the number of network entries, route paths, and the amount of memory used to process those entries. paths Displays the number of paths and the amount of memory used. denied paths Displays the number of denied paths and the amount of memory used. BGP path attribute entries Displays the number of BGP path attributes and the amount of memory used to process them.
Field Description between states and clearing the routes received, the phrase (Purging) may appear in this column. If the neighbor is disabled, the phrase (Admin shut) appears in this column. Example Dell#show ip bgp summary BGP router identifier 192.168.11.
network 1.1.11.1/32 network 1.1.12.1/32 network 1.1.13.1/32 neighbor 10.1.1.2 remote-as 200 neighbor 10.1.1.2 no shutdown Dell# timers bgp Adjust the BGP Keep Alive and Hold Time timers. Syntax timers bgp keepalive holdtime To return to the default, use the no timers bgp command. Parameters keepalive Enter a number for the time interval, in seconds, between keepalive messages sent to the neighbor routers. The range is from 1 to 65535. The default is 60 seconds.
Dell Networking OS Version Platform Support 7.8.1.0, MBGP for IPv4 Multicast Only S-Series debug ip bgp dampening View information on routes being dampened. Syntax debug ip bgp [vrf vrf-name] [ipv4 {unicast | multicast} | ipv6 unicast] dampening To disable debugging, use the no debug ip bgp dampening command. Parameters vrf vrf-name Enter the keyword vrf followed by the name of the VRF to view information on dampened routes corresponding to that VRF.
distance bgp Define an administrative distance for routes. Syntax distance bgp external-distance internal-distance local-distance To return to default values, use the no distance bgp command. Parameters Defaults external-distance Enter a number to assign to routes learned from a neighbor external to the AS. The range is from 1 to 255. The default is 20. internal-distance Enter a number to assign to routes learned from a router within the AS. The range is from 1 to 255. The default is 200.
show ip bgp dampened-paths View BGP routes that are dampened (non-active). Syntax Parameters Command Modes Command History show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] dampened-paths vrf vrf-name (OPTIONAL) Enter the keywords vrf and then the name of the VRF to view routes that are affected by a specific community list corresponding to that VRF.
Example Field Description From Displays the IP address of the neighbor advertising the dampened route. Reuse Displays the hour:minutes:seconds until the dampened route is available. Path Lists all the ASs the dampened route passed through to reach the destination network. Dell#show ip bgp dampened-paths BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.
10 Content Addressable Memory (CAM) Content addressable memory (CAM) commands are supported on the Dell Networking platform. NOTE: Not all CAM commands are supported on all platforms. Be sure to note the platform when looking for a command. WARNING: If you are using these features for the first time, contact Dell Networking Technical Assistance Center (TAC) for guidance. CAM Profile Commands The CAM profiling feature allows you to partition the CAM to best suit your application.
number] ecfmacl number [nlbclusteracl number] ipv4pbr number }openflow number | fcoe number} [iscsioptacl number] [vrfv4acl number] Parameters 396 default Use the default CAM profile settings and set the CAM as follows: • L2Acl : 6 • IPV4Acl : 4 • IPV6Acl : 0 • IPV4Qos : 2 • L2Qos : 1 • L2PT : 0 • IpMacAcl : 0 • VmanQos : 0 • VmanDualQos : 0 • EcfmAcl : 0 • nlbclusteracl: 0 • FcoeAcl : 0 • iscsiOptAcl : 0 • ipv4pbr : 0 • vrfv4Acl :0 • Openflow : 0 • fedgovacl : 0 l2acl n
NOTE: When you reconfigure CAM allocation, use the nlbclusteracl number command to change the number of NLB ARP entries. The range is from 0 to 2. The default value is 0. At the default value of 0, eight NLB ARP entries are available for use. This platform supports up to 512 CAM entries. Select 1 to configure 256 entries. Select 2 to configure 512 entries.
Usage Information Version Description 9.1.(0.0) Added support for OpenFlow. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.2 Clarified block information for the S4810. 8.3.10.0 Introduced on the S4810. 8.3.1.0 Added the keywords ecfmacl, vman-qos, and vman-dual-qos. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series.
Version Description 8.3.7.0 Introduced on the S4810. cam-optimization Optimize CAM utilization for QoS Entries by minimizing require policy-map CAM space. Syntax Parameters cam-optimization [qos] qos Optimize CAM usage for QoS. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series.
Ipv4Acl : Ipv6Acl : Ipv4Qos : L2Qos : L2PT : IpMacAcl : VmanQos : EcfmAcl : FcoeAcl : iscsiOptAcl : ipv4pbr : vrfv4Acl : Openflow : fedgovacl : nlbclusteracl: 4 4 2 1 0 0 0 0 0 0 0 0 0 0 0 test cam-usage Verify that enough CAM space is available for the IPv6 ACLs you have created. Syntax Parameters test cam-usage service-policy input input policy name stack-unit {number | all} policy-map name Enter the name of the policy-map to verify. Maximum is 32 characters.
Term Explanation Stack-Unit Lists the stack unit or units that are checked. Entering all shows the status for all stacks. Portpipe Lists the portpipe (port-set) or port pipes (port-sets) that are checked. Entering all shows the status for linecards or stack units and port-pipes in the chassis. The port set value is from 0 to 0. CAM Partition Shows the CAM profile of the CAM. Available CAM Identifies the amount of CAM space remaining for that profile.
Unified Forwarding Table Modes Unified Forwarding Table (UFT) consolidates the resources of several search tables (Layer 2, Layer 3 Hosts, and Layer 3 Route [Longest Prefix Match — LPM]) into a single flexible resource. Trident 2 supports several UFT modes to extract the forwarding tables, as required. By default, Dell Networking OS initializes the table sizes to UFT mode 2 profile, since it provides a reasonable shared memory for all the tables.
Example Version Description 9.7(0.0) Introduced on the S6000, S6000-ON, and Z9500 switch. Dell#show hardware forwarding-table mode Mode L2 MAC Entries L3 Host Entries L3 Route Entries : : : : Current Settings Default 160K 144K 16K Next Boot Settings scaled-l3-hosts 96K 208K 16K Dell# Related Commands 404 hardware forwarding-table mode — selects the mode to initialize the maximum scalability size for L2 MAC table or L3 Host table or L3 Route table.
11 Control Plane Policing (CoPP) The CoPP commands are supported on the Dell Networking platform. control-plane-cpuqos To manage control-plane traffic, enter control-plane mode and configure the switch. Syntax control-plane-cpuqos Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810.
Usage Information Version Description 8.3.8.0 Introduced on the S4810. This command applies the service-policy based on the type of protocol defined in the ACL rules. Create ACL and QoS policies prior to enabling this command. For CoPP, use the keyword cpu-qos when creating qos-policy-input. Related Commands ip access-list extended — creates an extended IP ACL. mac access-list extended — creates an extended MAC ACL. qos-policy-input — creates a QoS input policy map.
-------------Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q10 Q11 ----------1300 300 300 400 2000 300 400 400 400 600 300 300 ----------512 50 50 50 50 50 50 50 50 50 50 50 show ip protocol-queue-mapping Display the queue mapping for each configured protocol. Syntax show ip protocol-queue-mapping Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific.
Dell# Dell# Dell# show ipv6 protocol-queue-mapping Display the queue mapping for each configured IPv6 protocol. Syntax show ipv6 protocol-queue-mapping Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.
12 Data Center Bridging (DCB) Data center bridging (DCB) refers to a set of IEEE Ethernet enhancements that provide data centers with a single, robust, converged network to support multiple traffic types, including local area network (LAN), server, and storage traffic. The Dell Networking operating software commands for data center bridging features include 802.1Qbb priority-based flow control (PFC), 802.1Qaz enhanced transmission selection (ETS), and the data center bridging exchange (DCBX) protocol.
Usage Information Version Description 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. By default, iSCSI is enabled on the unit and the flow control is enabled on all of the interfaces. It is also acts as defaults when the link-level flow control is enabled on one or more interfaces. Enables priority flow control or enhance transmission selection on interface.
pfc no-drop queues Configure the port queues that still function as no-drop queues for lossless traffic. Syntax pfc no-drop queues queue-range To remove the no-drop port queues, use the no pfc no-drop queues command. Parameters queue-range Enter the queue range. Separate the queue values with a comma; specify a priority range with a dash; for example, pfc no-drop queues 1,3 or pfc no-drop queues 7 or pfc no-drop queues 0,7. The range is from 0 to 3. Defaults No lossless queues are configured.
pfc priority Configure the CoS traffic to be stopped for the specified delay. Syntax pfc priority priority-range To delete the pfc priority configuration, use the no pfc priority command. Parameters priority-range Enter the 802.1p values of the frames to be paused. Separate the priority values with a comma; specify a priority range with a dash; for example, pfc priority 1,3,5-7. The range is from 0 to 7. Defaults none Command Modes DCB INPUT POLICY Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. Usage Information Specify a stack-unit number on the Master switch in a stack.
Field Description Admin mode is on Admin is enabled PFC admin mode is on or off with a list of the configured PFC priorities. When the PFC admin mode is on, PFC advertisements are enabled to be sent and received from peers; received PFC configuration take effect. The admin operational status for a DCBX exchange of PFC configuration is enabled or disabled.
Field Description PFC TLV Statistics: Output TLV pkts Number of PFC TLVs transmitted. PFC TLV Statistics: Error pkts Number of PFC error packets received. PFC TLV Statistics: Pause Tx pkts Number of PFC pause frames transmitted. PFC TLV Statistics: Pause Rx pkts Number of PFC pause frames received.
Parameters port-type Enter the port type. slot/port [/subport] Enter the slot/port number. Enter the subport number if a 40G port is fanned-out into 10G ports. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module.
show interface ets Displays the ETS configuration applied to egress traffic on an interface, including priority groups with priorities and bandwidth allocation. Syntax show interface port-type slot/port[/subport] ets {summary | detail} Parameters port-type slot/ port[/subport] ets Enter the port-type slot and port ETS information. Enter the subport number if a 40G port is fanned-out into 10G ports.
TC-grp Priority# Bandwidth TSA -----------------------------------------------0 1 0,1,2 100% ETS 2 3 0 % SP 3 4,5,6,7 0 % SP 4 5 6 7 Oper status is init ETS DCBX Oper status is Down State Machine Type is Asymmetric Conf TLV Tx Status is enabled Reco TLV Tx Status is enabled 0 Input Conf TLV Pkts, 1955 Output Conf TLV Pkts, 0 Error Conf TLV Pkts 0 Input Reco TLV Pkts, 1955 Output Reco TLV Pkts, 0 Error Reco TLV Pkts Dell# show int te 1/3/1 ets de Interface TenGigabitEthernet 1/3/1 Max Supported TC Groups is
Dell# show interfaces tengigabitethernet 1/1/1 ets detail Interface TenGigabitEthernet 1/1/1 Max Supported TC Groups is 4 Number of Traffic Classes is 8 Admin mode is on Admin Parameters : -----------------Admin is enabled TC-grp Priority# Bandwidth TSA 0 0,1,2,3,4,5,6,7 100% ETS 1 0% ETS 2 0% ETS 3 0% ETS 4 0% ETS 5 0% ETS 6 0% ETS 7 0% ETS Priority# Bandwidth TSA 0 13% ETS 1 13% ETS 2 13% ETS 3 13% ETS 4 12% ETS 5 12% ETS 6 12% ETS 7 12% ETS Remote Parameters: ------------------Remote is disabled Local Pa
TC-grp Priority# 0 0,1,2,3,4,5,6,7 1 2 3 4 5 6 7 Bandwidth 100% 0% 0% 0% 0% 0% 0% 0% TSA ETS ETS ETS ETS ETS ETS ETS ETS Priority# 0 1 2 3 4 5 6 7 Remote Parameters: ------------------Remote is disabled Bandwidth 13% 13% 13% 13% 12% 12% 12% 12% TSA ETS ETS ETS ETS ETS ETS ETS ETS Bandwidth 100% 0% 0% 0% 0% 0% 0% 0% TSA ETS ETS ETS ETS ETS ETS ETS ETS Local Parameters : -----------------Local is enabled TC-grp Priority# 0 0,1,2,3,4,5,6,7 1 2 3 4 5 6 7 Priority# Bandwidth TSA 0 13% ETS 1 13% ETS 2 13
advertise dcbx-tlv On a DCBX port with a manual role, configure the PFC and ETS TLVs advertised to DCBX peers. Syntax advertise dcbx-tlv {ets-conf | ets-reco | pfc} [ets-conf | ets-reco | pfc] [ets-conf | ets-reco | pfc] To remove the advertised ETS TLVs, use the no advertise dcbx-tlv command. Parameters {ets-conf | ets-reco | pfc} Enter the PFC and ETS TLVs advertised, where: • ets-conf: enables the advertisement of ETS configuration TLVs. • ets-reco: enables the advertisement of ETS recommend TLVs.
Parameters config-source | auto-downstream | auto-upstream | manual Enter the DCBX port role, where: • config-source: configures the port to serve as the configuration source on the switch. • auto-upstream: configures the port to receive a peer configuration. The configuration source is elected from auto-upstream ports. • auto-downstream: configures the port to accept the internally propagated DCB configuration from a configuration source.
Defaults Auto Command Modes INTERFACE PROTOCOL LLDP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. fcoe priority-bits Configure the FCoE priority advertised for the FCoE protocol in application priority TLVs. Syntax fcoe priority-bits priority-bitmap To remove the configured FCoE priority, use the no fcoe priority-bits command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module.
Field Description Port-Role Configured the DCBX port role: auto-upstream, auto-downstream, config-source, or manual. DCBX Operational Status Operational status (enabled or disabled) used to elect a configuration source and internally propagate a DCB configuration. The DCBX operational status is the combination of PFC and ETS operational status. Configuration Source Specifies whether the port serves as the DCBX configuration source on the switch: true (yes) or false (no).
Example Field Description Total DCBX Frame errors Number of DCBX frames with errors received. Total DCBX Frames unrecognized Number of unrecognizable DCBX frames received.
Parameters map-name Enter a DCB map name. The maximum number of alphanumeric characters is 32. Defaults None. There are no pre-configured PFC and ETS settings on S5000 Ethernet interfaces. Command Modes CONFIGURATION INTERFACE Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810 and S6000 platforms. A DCB map is a template used to configure DCB parameters and apply them on converged Ethernet interfaces.
Command Modes Command History Usage Information DCB MAP Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810, S6000 platforms. PFC and ETS settings are not pre-configured on Ethernet ports. You must use the dcb-map command to configure different groups of 802.1p priorities with PFC and ETS settings. Using the priority-pgid command, you assign each 802.1p priority to one priority group. A priority group consists of 802.
Usage Information Version Description 9.3(0.0) Introduced on the S4810, S6000 platforms. Use the dcb-map command to configure priority groups with PFC and/or ETS settings and apply them to Ethernet interfaces. Use the priority-pgid command to map 802.1p priorities to a priority group. You can assign each 802.1p priority to only one priority group. A priority group consists of 802.
Usage Information Version Description 9.3(0.0) Introduced on the S4810 and S6000 platforms. The dcb-map stack-unit all stack-ports all command overwrites any previous DCB maps applied to stack ports. dcb pfc-shared-buffer-size Configure the maximum amount of shared buffer size for PFC packets in kilobytes. You must configure the shared buffer size to be less than the total PFC buffer size.
dcb-buffer-threshold Configure the profile name for the DCB buffer threshold. This utility is supported on the S4810, S4820T, and S6000 platforms. Syntax Parameters dcb buffer—threshold profile-name profile-name Enter the name of the profile, which can be a string of up to 32 characters in length. Default None Command Modes CONFIGURATION mode Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810, S4820T, and S6000 platforms.
size Weightage of the priorities on the shared buffer size in the system. Enter a number in the range of 0 to 9. The default shared threshold weight is 10. Default The default size of the ingress buffer is 45 KB. The default buffer limit at which the port sends the pause to peer and recommences the sending of packets to the peer is 10 KB. The default threshold weight of the shared buffer space is 10. Command Modes DCB-BUFFER-THRESHOLD mode Command History Usage Information Version Description 9.
no-drop The packets for this queue must not be dropped value Enter a number in the range of 0 to 7 to denote the priority to be allocated to the dynamic buffer control mechanism buffer-size Ingress buffer size size Size of the ingress buffer in KB. Enter a number in the range of 0 to 7787. The default is 45 KB. pause-threshold Buffer limit for pause frames to be sent threshold-value Buffer limit at which the port sends the pause to peer in KB. Enter a number in the range of 0 to 7787.
Dell(conf-qos-policy-buffer)# queue 4 pause no-drop buffer-size 128000 pause-threshold 103360 resume-threshold 83520 dcb-policy buffer-threshold (Interface Configuration) Assign the DCB policy to the DCB buffer threshold profile on interfaces. This setting takes precedence over the global bufferthreshold setting.
Usage Information Example Version Description 9.3(0.0) Introduced on the S6000 platform.
Example Dell(conf)#dcb pfc-total-buffer-size 5000 Dell(conf)#dcb pfc-total-buffer-size 4000 %ERROR: Total pfc buffer size configured cannot accommodate existing buffer requirement in the system. show running-config dcb-buffer-threshold Displays the DCB buffer threshold details in the running configuration. Syntax show running—config buffer-threshold Command Modes EXEC EXEC Privilege Command History Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.
5 6 7 - No No No Denotes dynamic buffering is enabled in respective queues On interface in which PFC is not enabled: Dell#show interface tengigabitethernet 1/20/1 pfc buffer-threshold The following table describes the output fields displayed for the show interface pfc buffer-threshold comm Field Description queue Number of the queue lossless Whether the queue is a lossy or lossless queue for wh threshold is configured buffer-size Ingress buffer size pause-threshold-value Buffer limit at which
dcb {ets | pfc} enable Enable priority flow control or enhanced transmission selection on interface. Syntax dcb {ets | pfc} enable • To disable ETS on interface, use “no dcb ets enable” command. • To disable PFC on interface, use “no dcb pfc enable” command. Defaults Enable Command Modes INTERFACE Command History Usage Information Limitations 442 Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3 (0.1) Introduced on S6000, S4810, and S4820T.
13 Debugging and Diagnostics The basic debugging and diagnostic commands are supported by the Dell Networking Operating System. This chapter contains the following sections: • Diagnostic and Monitoring Commands • Offline Diagnostic Commands • Hardware Commands Diagnostics and Monitoring Commands The following section describes the diagnostics and monitoring commands. For similar commands, refer to the Control and Monitoring chapter. logging coredump stack-unit Enable coredump on a stack.
Offline Diagnostic Commands The offline diagnostics test suite is useful for isolating faults and debugging hardware. While tests are running, Dell Networking OS results are saved as a text file (TestReport-SU-X.txt) in the flash directory. This show file command is available only on master and standby. Important Points to Remember • Offline diagnostics can only be run when the unit is offline. • You can only run offline diagnostics on a unit to which you are connected via the console.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced the verbose option. 7.7.1.
Warning - Diagnostic execution will cause stack-unit to reboot after completion of diags. Proceed with Offline-Diags [confirm yes/no]:y online stack-unit Place a stack unit in the online state. Syntax online stack-unit number Parameters number Enter the stack-unit number. The range is from 1 to 6. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
Hardware Commands These commands display information from a hardware sub-component or ASIC. clear hardware stack-unit Clear statistics from selected hardware components.
clear hardware system-flow Clear system-flow statistics from selected hardware components. Syntax clear hardware system-flow layer2 stack-unit number port-set 0–0 counters Parameters stack-unit number Enter the keywords stack-unit then a number to select a particular stack member and then enter one of the following command options to clear a specific collection of data. The range is from 1 to 6.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced this command. hardware watchdog To trigger a reboot and restart the system, set the watchdog timer. Syntax hardware watchdog stack-unit {<0-5> | all} Defaults Enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. The unit numbers given are internal port numbers. show hardware layer3 Display Layer 3 ACL or QoS data for the selected stack member and stack member port-pipe.
show hardware stack-unit Display the data plane or management plane input and output statistics of the designated component of the designated stack member.
The following is a list of the Dell Networking OS version history for this command. Example (DataPlane) Version Description 9.8(0.0) Replaced the keyword port with interface. 9.7(0.0) Introduced on the S6000-ON. 9.2(0.2) Modified the drops keyword range, unit keyword range and added the buffer and cpu management statistics options. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.5 Added i2c statistics and sata-interfaces statistics. 8.3.11.
Example (PortStats) Dell#show hardware stack-unit 1 unit 0 ena/ speed/ link auto STP port link duplex scan neg? state pause ge0 down SW Yes Block ge1 !ena SW Yes Block ge2 !ena SW Yes Block ge3 !ena SW Yes Block ge4 !ena SW Yes Forward ge5 !ena SW Yes Forward ge6 !ena SW Yes Forward ge7 !ena SW Yes Forward ge8 !ena SW Yes Forward ge9 !ena SW Yes Forward ge10 !ena SW Yes Forward ge11 !ena SW Yes Forward ge12 !ena SW Yes Forward ge13 !ena SW Yes Forward ge14 !ena SW Yes Forward ge15 !ena SW Yes Forward ge16
0x0e700102 BCAST_BLOCK_MASK.ge0 = 0x00000000 0x0e701102 BCAST_BLOCK_MASK.ge1 = 0x00000000 0x0e702102 BCAST_BLOCK_MASK.ge2 = 0x00000000 0x0e703102 BCAST_BLOCK_MASK.ge3 = 0x00000000 0x0e704102 BCAST_BLOCK_MASK.ge4 = 0x00000000 0x0e705102 BCAST_BLOCK_MASK.ge5 = 0x00000000 0x0e706102 BCAST_BLOCK_MASK.ge6 = 0x00000000 0x0e707102 BCAST_BLOCK_MASK.ge7 = 0x00000000 0x0e708102 BCAST_BLOCK_MASK.ge8 = 0x00000000 0x0e709102 BCAST_BLOCK_MASK.ge9 = 0x00000000 0x0e70a102 BCAST_BLOCK_MASK.
RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX - Pause Control Frame Counter Oversized Frame Counter Jabber Frame Counter VLAN Tag Frame Counter Double VLAN Tag Frame Counter RUNT Frame Counter Fragment Counter VLAN Tagged Packets Ingress Dropped Packet MTU Check Error Frame Counter PFC Frame Priority 0 PFC Frame Priority 1 PFC Frame Priority 2 PFC
TX - Debug Counter 10 TX - Debug Counter 11 --------------------unit: 0 port: 61 (interface Fo 1/60/1) Description RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX RX TX TX TX TX TX TX TX TX TX 456 - IPV4 L3 Unicast Frame Counter IPV4 L3 Routed Multicast Packets IPV6 L3 Unicast Frame Counter IPV6 L3 Routed Multicast Packets Unicast Packet Counter 64 Byte Frame Counter 65 to 127 Byte Frame Counter 128 to 255 Byt
TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX TX Example (Details) - 4096 to 9216 Byte Frame Counter Good Packet Counter Packet/Frame Counter Unicast Frame Counter Multicast Frame Counter Broadcast Frame Counter Byte Counter Control Frame Counter Pause Control Frame Counter Oversized Frame Counter Jabber Counter VLAN Tag Frame Counter Double VLAN Tag Frame Counter RUNT Frame Counter Fragment Counter PFC Frame Priority 0 PFC Frame Priority 1 PFC Frame
The linkStatus of Front End Port 7 is FALSE The linkStatus of Front End Port 8 is FALSE The linkStatus of Front End Port 9 is FALSE The linkStatus of Front End Port 10 is FALSE The linkStatus of Front End Port 11 is FALSE The linkStatus of Front End Port 12 is FALSE The linkStatus of Front End Port 13 is FALSE The linkStatus of Front End Port 14 is FALSE The linkStatus of Front End Port 15 is FALSE The linkStatus of Front End Port 16 is FALSE The linkStatus of Front End Port 17 is FALSE The linkStatus of Fr
show system (S-Series and Z-Series) — displays the current status of all the stack members or a specific member. show hardware stack-unit buffer Display the counters for the specified port, minimum guaranteed buffer of a priority-group, and the shared buffer.
Usage Information Example Version Description Version 9.3(0.0) Introduced on the S6000 platform. The following table describes the fields in the output of the show command: Field Description Buffer Accounting Stats for Unit 0 Port 1 prioritygroup 0 Displays the counters that are calculated by the buffer statistics tracking method for each port per priority group on a particular stack member.
Maximum Shared Limit: 7667 Default Packet Buffer allocate for the Queue: 8 Used Packet Buffer: 0 ----- Buffer Stats for Interface Te 1/1/1 Queue Maximum Shared Limit: 7667 Default Packet Buffer allocate for the Queue: 8 Used Packet Buffer: 0 ----- Buffer Stats for Interface Te 1/2/1 Queue Maximum Shared Limit: 7667 Default Packet Buffer allocate for the Queue: 8 Used Packet Buffer: 0 ----- Buffer Stats for Interface Te 1/3/1 Queue Maximum Shared Limit: 7667 Default Packet Buffer allocate for the Queue: 8 Us
Usage Information -Queue ucast/mcast — Displays the total unicast/multicast buffer usage on per-port per-queue basis. For CPU port, counters for queues 0 to 11 displays and there is no differentiation between unicast and multicast queues.
--------------------------------------MCAST 3 0 Dell#show hardware buffer-stats-snapshot resource interface fortyGigE 1/1 queue mcast all Unit 1 unit: 0 port: 1 (interface Fo 1/1) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------MCAST 0 0 MCAST 1 0 MCAST 2 0 MCAST 3 0 MCAST 4 0 MCAST 5 0 MCAST 6 0 MCAST 7 0 MCAST 8 0 Example displaying ingress prioritygroup level snapshot for the specific interface Dell#show hardware buffer-stats-snapshot resource
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.8(0.0) Introduced on the S4810, S4820T, S5000, S6000, S6000–ON, Z9500.
show hardware drops Displays internal drops on the specified interface or for a range of interface. Syntax Parameters show hardware drops interface interface interface drops Command Modes Enter any of the following keywords and slot/port[/subport] or slot/port-range or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Packets dropped by FP (L2+L3) Drops Port bitmap zero Drops Rx VLAN Drops --- Ingress MAC counters--Ingress FCSDrops Ingress MTUExceeds --- MMU Drops --Ingress MMU Drops HOL DROPS(TOTAL) HOL DROPS on COS0 HOL DROPS on COS1 HOL DROPS on COS2 HOL DROPS on COS3 HOL DROPS on COS4 HOL DROPS on COS5 HOL DROPS on COS6 HOL DROPS on COS7 HOL DROPS on COS8 HOL DROPS on COS9 HOL DROPS on COS10 HOL DROPS on COS11 HOL DROPS on COS12 HOL DROPS on COS13 HOL DROPS on COS14 HOL DROPS on COS15 HOL DROPS on COS16 HOL DROPS on
(OPTIONAL) Enter the keyword counters to display hit counters for the selected ACL or QoS option. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
############ EID 2045: gid=1, slice=15, slice_idx=0x02, prio=0x7fd, flags=0x82, Installed tcam: color_indep=0, higig=0, higig_mask=0, KEY=0x00000000 00000000 00000000 0180c200 00020000 00000000 00000000 , FPF4=0x00 MASK=0x00000000 00000000 00000000 ffffffff ffff0000 00000000 00000000 , 0x00 action={act=Drop, param0=0(0x00), param1=0(0x00)}, action={act=CosQCpuNew, param0=7(0x07), param1=0(0x00)}, action={act=CopyToCpu, param0=0(0x00), param1=0(0x00)}, action={act=UpdateCounter, param0=1(0x01), param1=0(0x00
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced this command. Example Dell#show hardware vlan-counters 1 Counters for vlanid: 1 -----------------------Total number of inpackets: 0 Total number of inbytes: 0 Total number of outpackets: 0 Total number of outbytes: 0 Dell# Related Commands clear hardware system-flow — clears the statistics from selected hardware components.
Usage Information The following information is displayed depending on whether the historical snapshot of buffer statistics is needed for all ports, per-port per-queue, or a priority group. • All – Displays all resources on ingress and egress for each of the port, queue. • Port-Queue ucast/mcast – Displays the total unicast/multicast buffer usage on per-port per-queue basis. For CPU port, counters for queues 0 – 11 are displayed and no differentiation is made between unicast and multicast queues.
-----------------------------------------------------------------------------------6 1000 5 7 3 0 show hardware stack-unit buffer-stats-snapshot (Total Buffer Information) View the buffer statistics tracking resource information depending on the type of buffer information, such as device-level details, port-level counters, queue-based snapshots, or priority group-level snapshot in the egress and ingress direction of traffic.
When the buffer-stats-snapshot is disabled, the following informational message is displayed when you run the show command: %Info: Buffer-stats-snapshot feature is disabled.
14 Dynamic Host Configuration Protocol (DHCP) Dynamic host configuration protocol (DHCP) is an application layer protocol that dynamically assigns IP addresses and other configuration parameters to network end-stations (hosts) based on the configuration policies the network administrators determine. The Dell Networking operating system supports the basic DHCP commands on this platform.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. Entering after the clear ip dhcp binding command clears all the IPs from the binding table. debug ip dhcp server Display FTOS debugging messages for DHCP. Syntax debug ip dhcp server [events | packets] Parameters events Enter the keyword events to display the DHCP state changes.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. default-router Assign a default gateway to clients based on the address pool. Syntax Parameters default-router address [address2...address8] address Enter a list of routers that may be the default gateway for clients on the subnet. You may specify up to eight routers. List them in order of preference.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series.
Parameters name Give a name to the group of addresses in a pool. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
hardware-address For manual configurations, specify the client hardware address. Syntax hardware-address address Parameters address Enter the hardware address of the client. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. lease Specify a lease time for the addresses in a pool. Syntax Parameters lease {days [hours] [minutes] | infinite} days Enter the number of days of the lease. The range is from 0 to 31. hours Enter the number of hours of the lease. The range is from 0 to 23. minutes Enter the number of minutes of the lease. The range is from 0 to 59.
Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
network Specify the range of addresses in an address pool. Syntax network network /prefix-length Parameters network/ prefixlength Specify a range of addresses. Prefix-length range is from 17 to 31. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. show ip dhcp binding Display the DHCP binding table. Syntax show ip dhcp binding Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. show ip dhcp conflict Display the address conflict log. Syntax Parameters show ip dhcp conflict address address Display a particular conflict log entry. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. Commands to Configure Secure DHCP DHCP, as defined by RFC 2131, provides no authentication or security mechanisms. Secure DHCP is a suite of features that protects networks that use dynamic address allocation from spoofing and attacks.
Defaults Command Modes Command History Disabled • INTERFACE • INTERFACE PORT-CHANNEL This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Added the keywords discard-counters, interface, and the variable interface on the S4810, S4820T, S5000, S6000, Z9000, Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.
ip dhcp relay Enable Option 82. Syntax ip dhcp relay information-option [remote-id | trust-downstream] Parameters remote-id Configure the system to enable the remote-id string in option-82. trust-downstream Configure the system to trust Option 82 when it is received from the previous-hop router. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Usage Information Version Description 8.3.1.0 Introduced on the E-Series. 8.2.1.0 Introduced on the C-Series and S-Series on Layer 2 interfaces. 7.8.1.0 Introduced on the C-Series and S-Series on Layer 3 interfaces. When enabled, no learning takes place until you enable snooping on a VLAN. After disabling DHCP snooping, the binding table deletes and Option 82, IP Source Guard, and Dynamic ARP Inspection are disabled. Introduced in Dell Networking OS version 7.8.1.
Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp snooping binding Create a static entry in the DHCP binding table. Syntax Parameters Defaults Command Modes Command History [no] ip dhcp snooping binding mac address vlan-id vlan-id ip ip-address interface type slot/port[/subport] lease number mac address Enter the keyword mac then the MAC address of the host to which the server is leasing the IP address.
Related Commands Version Description 8.3.1.0 Introduced on the E-Series. 7.8.1.0 Introduced on the C-Series and S-Series. show ip dhcp snooping — displays the contents of the DHCP binding table. IPv6 DHCP Snooping Binding Create a static DHCP snooping binding entry in the snooping database.
ip dhcp snooping database Delay writing the binding table for a specified time. Syntax Parameters ip dhcp snooping database write-delay minutes minutes The range is from 5 to 21600. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.
Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp snooping database renew Renew the binding table. Syntax ip dhcp snooping database renew Defaults none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
ip dhcp snooping trust Configure an interface as trusted. Syntax [no] ip dhcp snooping trust Defaults Untrusted Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
vlan vlan-id Defaults Disabled Command Modes INTERFACE (OPTIONAL) SAV validates the source IP address along with the source VLAN ID against the DHCP snooping binding table. INTERFACE PORTCHANNEL Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
NOTE: Adds the VPN/VRF related sub-options into the relay agent information option(82). When DHCP broadcasts are forwarded by the relay agent from clients to DHCP server. Default Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
Version Description 8.3.1.0 Introduced on the E-Series. 7.2.1.0 Introduced on the C-Series and S-Series. ipv6 dhcp snooping verify mac-address Syntax [no] ipv6 dhcp snooping verify mac-address To disable verify source mac-address against IPv6 DHCP packet MAC address, use the no ipv6 dhcp snooping verify mac-address command. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Usage Information Use this command on the interfaces where the DHCP clients are connected to forward the packets from clients to DHCP server and vice-versa. Example Dell(conf-if-fo-1/12)#ip helper-address vrf jay 10.0.0.2 ipv6 helper-address Configures the ipv6 DHCP helper addresses without VRF. Syntax [no] ipv6 helper-address ipv6-address To delete the ipv6 helper address, use the [no] ipv6 helper-address ipv6-address command.
interface interface (OPTIONAL) Specifies an interface to show the discard counters. Enter any of the following keywords and slot/port[/subport] or number information: Defaults • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
permit host 0.0.0.0 host 00:00:00:00:00:00 count (0 packets) permit vlan 10 host 1.1.1.1 host 00:00:00:00:01:01 count (0 packets) permit vlan 10 host 1.1.1.2 host 00:00:00:00:01:02 count (0 packets) permit vlan 10 host 1.1.1.3 host 00:00:00:00:01:03 count (0 packets) ipmac-vlan sav access-list on Port-channel 10 on stack-unit 2 Total cam count 5 permit host 0.0.0.0 host 00:00:00:00:00:00 count (0 packets) permit vlan 10 host 1.1.1.1 host 00:00:00:00:01:01 count (0 packets) permit vlan 10 host 1.1.1.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. Dell#show ipv6 dhcp snooping IPv6 DHCP Snooping IPv6 DHCP Snooping Mac Verification : Enabled. : Disabled.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S-Series and Z-Series. Usage Information Use this command to associate name server IP addresses to a specific VRF.
ip domain-list Adds a domain name to the DNS list. This domain name is appended to incomplete host names in DNS requests corresponding to a specific VRF. Syntax ip domain-list [vrf vrf-name] name To remove a domain name from DNS list, use the no ip domain-list [vrf vrf-name] name command. Parameters vrf vrf-name (Optional) Enter the key word vrf and then the name of the VRF to add a domain name to the DNS list corresponding to that VRF.
ip-address Enter the IP address of the name server in dotted decimal format. Defaults None Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S-Series and Z-Series.
15 Equal Cost Multi-Path (ECMP) Equal cost multi-path (ECMP) is supported on the Dell Networking OS. ecmp-group Provides a mechanism to monitor traffic distribution on an ECMP link bundle. A system log is generated when the standard deviation of traffic distribution on a member link exceeds a defined threshold. Syntax ecmp-group {ecmp-group-id interface interface | link-bundle-monitor} To remove the selected interface, use the ecmp-group no interface command.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. Using CONFIGURATION mode, create an ECMP group ID. You can then assign interfaces to the ECMP group using CONFIGURATION ECMP-GROUP mode. You can also enable on the port-channel configuration using the CONFIGURATION ECMP-GROUP command mode. hash-algorithm Changes the hash algorithm used to distribute traffic flows across a Port Channel. The ECMP and LAG options are supported on the Z-Series.
hg {crc16 | crc16cc | crc32MSB | crc32LSB | xor1 | xor2 | xor4 | xor8 | xor16} stack-unit stack-unit-number | port-set port-pipe • xor8: Use CRC16_BISYNC_AND_XOR8 — Upper 8 bits of CRC16-BISYNC and lower 8 bits of xor8 • xor16: Use CR16 — 16 bit XOR Z-Series only: Enter the keyword hg then one of the following options: • crc16: Use CRC16_BISYNC — 16 bit CRC16-bisync polynomial (default) • crc16cc: Use CRC16_CCITT — 16 bit CRC16 using CRC16-CCITT polynomial • crc32MSB: Use CRC32_UPPER — MSB 16 bits
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. 8.1.1.
ip ecmp-group Enable and specify the maximum number of ecmp that the L3 CAM hold for a route, By default, when maximum paths are not configured, the CAM can hold a maximum of 16 ecmp per route. Syntax ip ecmp-group {maximum-paths | {number} {path-fallback} To negate a command, use the no ip ecmp-group maximum-paths {number} command. Parameters maximum-paths Specify the maximum number of ECMP for a route. The range is 2 to 64. path-fallback Use the keywords path-fallback to enable this feature.
If disabled, the CLI would inform the FIB to re-program the destination prefix paths with no weights or regular ECMP.
link-bundle-monitor enable Provides a mechanism to enable monitoring of traffic distribution on an ECMP link bundle. Syntax link-bundle-monitor enable To exit from ECMP group mode, use the exit command. Command Modes Command History • ECMP-GROUP • PORT-CHANNEL INTERFACE This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
16 Flex Hash and Optimized Boot-Up This chapter describes the Flex Hash and fast-boot enhancements. load-balance ingress-port enable Enable the Flex hash functionality. This utility is supported on the platform. Syntax load-balance ingress-port enable To disable the Flex hash capability, use the no version of this command. Default None Command Modes CONFIGURATION mode Command History Usage Information Version 9.3(0.0) Introduced on the S6000 platform.
Parameters ipv4 Denotes whether Flex Hash needs to be enabled for IPv4 packets. ipv6 Denotes whether Flex Hash needs to be enabled for IPv6 packets. protocol number Represents the Outer IPv4 protocol field in case of IPv4 packets, and the Outer IPv6 next header field in case of IPv6 packets. The ipv4/ipv6 keyword and the IP protocol value are used as keys to identify if a duplicate flex hash configuration is already present. Duplicate flex hash configuration is not possible.
reload-type fastboot Restart the system with optimized booting-time functionality enabled. When you restart the device in fast boot mode, traffic disruption is reduced significantly and the system operations to service the data traffic are restored in a seamless way. C9000 Series Syntax Parameters reload-type fastboot fastboot Enable the system to restart the next time with the optimized booting-time capability Defaults By default, the device reloads in Jumpstart or BMP mode.
Usage Information Version Description 9.3(0.0) Introduced on the S6000. You can configure the optimal switchover functionality for LACP even if you do not enable the fast boot mode on the system. You must configure the long timeout mechanism for the LACP session to enable the fast boot capability to operate properly. This command applies to dynamic port-channel interfaces only.
17 FIP Snooping To enable the FCoE Transit feature and configure FIP snooping, use the following Dell Networking Operating System commands on the platform. In a converged Ethernet network, a switch can operate as an intermediate Ethernet bridge to snoop on FIP packets during the login process on Fibre Channel over Ethernet (FCoE) forwarders (FCFs).
clear fip-snooping statistics Clears the statistics on the FIP packets snooped on all VLANs, a specified VLAN, or a specified port interface. Syntax clear fip-snooping statistics [interface vlan vlan-id | interface fortyGigEport-type port/slot[/subport] | interface port-channel portchannel-number] Parameters vlan-id Enter the VLAN ID of the FIP packet statistics to be cleared. port-type port/slot Enter the port-type and slot number of the FIP packet statistics to be cleared.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. debug fip snooping rx Enable debugging for FIP snooping receive-specific packets.
Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 9.2(0.2) Introduced on the S4810 and S4820T. Added the receive parameters packettype and interfaces and their options. feature fip-snooping Enable FCoE transit and FIP snooping on a switch. Syntax feature fip-snooping To disable the FCoE transit feature, use the no feature fip-snooping command. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. The maximum number of FCFs supported per FIP snooping-enabled VLAN is four.
fip-snooping max-sessions-per-enodemac Configure the maximum session limit per ENode MAC address. Syntax fip-snooping max—sessions—per—enode—mac max-sessions-value To return the configured maximum sessions to the default value, use the no fip-snooping max— sessions—per—enode—mac command. Parameters max-sessions-value Enter the maximum number of sessions allowed per ENode MAC address. The range is from 1 to 64.
fip-snooping port-mode fcoe-trusted Configure the port for bridge-to-bridge links. Syntax fip-snooping port-mode fcoe-trusted To remove the bridge-to-bridge link configuration from the port, use the no fip-snooping port-mode fcoe-trusted command. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Dell# show fip-snooping config FIP Snooping Feature enabled Status: Enabled FIP Snooping Global enabled Status: Enabled Global FC-MAP Value: 0X0EFC00 FIP Snooping enabled VLANs VLAN Enabled FC-MAP ----------------100 TRUE 0X0EFC00 show fip-snooping enode Display information on the ENodes in FIP-snooped sessions, including the ENode interface and MAC address, FCF MAC address, VLAN ID and FC-ID.
--------- --------------- ------- ---- ----d4:ae:52:1b:e3:cd Te 1/11/1 54:7f:ee:37:34:40 100 62:00:11 show fip-snooping fcf Display information on the FCFs in FIP-snooped sessions, including the FCF interface and MAC address, FCF interface, VLAN ID, FC-MAP value, FKA advertisement period, and number of ENodes connected. Syntax Parameters Command Modes Command History show fip-snooping fcf [fcf-mac-address] fcf-mac-address • EXEC • EXEC Privilege Enter the MAC address of the FCF to display.
show fip-snooping statistics Display statistics on the FIP packets snooped on all interfaces, including VLANs, physical ports, and port channels. Syntax show fip-snooping statistics [interface vlan vlan-id | interface port-type port/slot[/subport] | interface port-channel port-channel-number] Parameters Command Modes Command History vlan-id Enter the VLAN ID of the FIP packet statistics displays.
Example Field Description Number of VN Port Keep Alives Number of FIP-snoop VN port (Virtual N-port) keep-alive frames received on the interface Number of Multicast Discovery Advertisements Number of FIP-snoop multicast discovery advertisements received on the interface. Number of Unicast Discovery Advertisements Number of FIP-snoop unicast discovery advertisements received on the interface. Number of FLOGI Accepts Number of FIP FLOGI accept frames received on the interface.
Number of Session failures due to Hardware Config :0 Dell(conf)# Dell# show fip-snooping statistics int tengigabitethernet 1/11/1 Number of Vlan Requests :1 Number of Vlan Notifications :0 Number of Multicast Discovery Solicits :1 Number of Unicast Discovery Solicits :0 Number of FLOGI :1 Number of FDISC :16 Number of FLOGO :0 Number of Enode Keep Alive :4416 Number of VN Port Keep Alive :3136 Number of Multicast Discovery Advertisement :0 Number of Unicast Discovery Advertisement :0 Number of FLOGI Accepts
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
show fips status Display the FIPs status on the platform. Syntax show fips status Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. 528 FIP Snooping Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.
18 Force10 Resilient Ring Protocol (FRRP) Force10 resilient ring protocol (FRRP) is supported on Dell Networking OS. FRRP is a proprietary protocol for that offers fast convergence in a Layer 2 network without having to run the spanning tree protocol (STP). The resilient ring protocol is an efficient protocol that transmits a high-speed token across a ring to verify the link status. All the intelligence is contained in the master node with practically no intelligence required of the transit mode.
Usage Information Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series. 7.5.1.0 Introduced. Executing this command without the optional ring-id command clears the statistics counters on all the available rings. Dell Networking OS requires a command line confirmation before the command executes.
Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 8.2.1.0 Introduced on the C-Series. 7.4.1.0 Introduced. disable Disable the resilient ring protocol. Syntax disable To enable the Resilient Ring Protocol, use the no disable command. Defaults Disabled Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters primary interface secondary interface control-vlan vlan-id Enter the keyword primary to configure the primary interface then one of the following interfaces and slot/port[/subport] information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
member-vlan Specify the member VLAN identification numbers. Syntax member-vlan {vlan-range} To return to the default, use the no member-vlan [vlan-range] command. Parameters vlan-range Enter the member VLANs using VLAN IDs (separated by commas), a range of VLAN IDs (separated by a hyphen), a single VLAN ID, or a combination. For example: VLAN IDs (comma-separated): 3, 4, 6. Range (hyphen-separated): 5-10. Combination: 3, 4, 5-10, 8.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series. 7.4.1.
Usage Information This command places you into the resilient ring protocol. After executing this command, the command line prompt changes to conf-frrp. show frrp Display the resilient ring protocol configuration. Syntax show frrp [ring-id [summary]] | [summary] Parameters ring-id Enter the ring identification number. The range is from 1 to 255 summary (OPTIONAL) Enter the keyword summary to view just a summarized version of the Ring configuration.
• The number of state change counters Example (Summary) Dell#show frrp summary Ring-ID State Mode Ctrl_Vlan Member_Vlans ---------------------------------------------2 UP Master 2 11-20, 25,27-30 31 UP Transit 31 40-41 50 Down Transit 50 32 Dell# Example (1) Dell#show frrp 1 Ring protocol 1 is in Master mode Ring Protocol Interface: Primary : TenGigabitEthernet 1/16/1 State: Forwarding Secondary: Port-channel 100 State: Blocking Control Vlan: 1 Ring protocol Timers: Hello-Interval 50 msec Dead-Interval 1
NOTE: The configured dead interval must be at least three times the hello interval. Defaults • 500 ms for hello-interval milliseconds • 1500 ms for dead-intervalmilliseconds Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
19 GARP VLAN Registration (GVRP) The Dell Networking operating system supports the basic GVRP commands on the Dell Networking OS. The generic attribute registration protocol (GARP) mechanism allows the configuration of a GARP participant to propagate through a network quickly. A GARP participant registers or de-registers its attributes with other participants by making or withdrawing declarations of attributes.
clear gvrp statistics Clear GVRP statistics on an interface. Syntax clear gvrp statistics interface interface Parameters interface interface Enter the following keywords and slot/port[/subport] or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
To disable debugging, use the no debug gvrp {config | events | pdu} command. Parameters config Enter the keyword config to enable debugging on the GVRP configuration. event Enter the keyword event to enable debugging on the JOIN/LEAVE events. pdu Enter the keyword pdu then one of the following Interface keywords and slot/ port[/subport] or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series gvrp enable — enables GVRP on physical interfaces and LAGs. protocol gvrp — access GVRP protocol.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series disable — globally disables GVRP. gvrp registration Configure the GVRP register type. Syntax gvrp registration {fixed | normal | forbidden} To return to the default, use the gvrp register normal command.
Usage Information Fixed registration prevents an interface, configured using the command line, to belong to a VLAN (static configuration) from being unconfigured when it receives a Leave message. Therefore, Registration mode on that interface is fixed. Normal registration is the default registration. The port’s membership in the VLAN depends on GVRP. The interface becomes a member of a VLAN after learning about the VLAN through GVRP.
show config Display the global GVRP configuration. Syntax show config Command Modes CONFIGURATION-GVRP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series Example Dell#show garp timers GARP Timers Value (milliseconds) ---------------------------------------Join Timer 200 Leave Timer 600 LeaveAll Timer 10000 Dell# Related Commands garp timers — sets the intervals (in milliseconds) for sending GARP messages.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series Usage Information If no ports are GVRP participants, the message output changes from GVRP Participants running on to GVRP Participants running on no ports. Example R3#show gvrp brief GVRP Feature is currently enabled.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 7.6.1.
20 ICMP Message Types This chapter lists and describes the possible ICMP message type resulting from a ping. The first three columns list the possible symbol or type/code. For example, you would receive a ! or 03 as an echo reply from your ping. ICMP Messages and Their Definitions. Symbol Type Code . 0 U 3 4 3 Error ICMP Message Types echo reply . destination unreachable: 0 network unreachable . 1 host unreachable . 2 protocol unreachable . 3 port unreachable .
Symbol & Type Code Description Query 8 0 echo request . 9 0 router advertisement . 10 0 router solicitation . 11 Error time exceeded: 0 time-to-live equals 0 during transit . 1 time-to-live equals 0 during reassembly . 12 parameter problem: 1 IP header bad (catchall error) . 2 required option missing . 13 0 timestamp request . 14 0 timestamp reply . 15 0 information request (obsolete) . 16 0 information reply (obsolete) . 17 0 address mask request .
21 Internet Group Management Protocol (IGMP) The IGMP commands are supported by the Dell Networking operating software on the Dell Networking OS. This chapter contains the following sections: • IGMP Commands • IGMP Snooping Commands IGMP Commands Dell Networking OS supports IGMPv1/v2/v3 and is compliant with RFC-3376.
• For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF.
• For a port channel interface, enter the keywords port-channel then a number. Defaults Disabled. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. 7.6.1.0 Introduced on E-Series. The access list accepted is an extended ACL. To block IGMP reports from hosts, on a per-interface basis based on the group address and source address that you specify in the access list, use this feature. ip igmp immediate-leave Enable IGMP immediate leave.
ip igmp last-member-query-interval Change the last member query interval, which is the Max Response Time inserted into Group-Specific Queries sent in response to Leave Group messages. This interval is also the interval between Group-Specific Query messages. Syntax ip igmp last-member-query-interval milliseconds To return to the default value, use the no ip igmp last-member-query-interval command. Parameters milliseconds Enter the number of milliseconds as the interval.
Parameters seconds Enter the number of seconds between queries sent out. The range is from 1 to 18000. The default is 60 seconds. Defaults 60 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Defaults 10 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF and Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series. show ip igmp groups View the IGMP groups. Syntax show ip igmp [vrf vrf-name] groups [group-address [detail] | detail | interface [group-address [detail]]] Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series and C-Series. 7.5.1.0 Expanded to support the detail option. E-Series legacy command. Usage Information This command displays the IGMP database, including configured entries for either all groups on all interfaces, all groups on specific interfaces, or specific groups on specific interfaces.
Example (Details) Dell#show ip igmp group details Interface Vlan 20 Group 232.1.1.5 Uptime 00:11:22 Expires Never Router mode INCLUDE Last reporter 35.0.0.2 Group source list Source address Expires 65.0.0.1 00:01:22 65.0.0.2 00:01:22 65.0.0.3 00:01:22 65.0.0.4 00:01:22 65.0.0.5 00:01:22 show ip igmp interface View information on the interfaces participating in IGMP.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command. Usage Information IGMP commands accept only non-VLAN interfaces — specifying VLAN does not yield results. The show ip igmp interface command does not display information corresponding to the loop-back interfaces.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. 7.7.1.0 Introduced on the E-Series. Example Dell#show ip igmp ssm-map Interface Vlan 20 Group 232.1.1.
Important Points to Remember for IGMP Querier • The IGMP snooping Querier supports version 2. • You must configure an IP address to the VLAN interface for IGMP snooping Querier to begin. The IGMP snooping Querier disables itself when a VLAN IP address is cleared, and then it restarts itself when an IP address is reassigned to the VLAN interface. • When enabled, IGMP snooping Querier does not start if there is a statically configured multicast router interface in the VLAN.
Parameters • To disable debugging of IGMP snooping, use the no debug ip igmp snooping [group address | interface] command. • To disable all debugging, use the undebug all command. snooping Enter the keyword snooping to enable debugging of IGMP snooping. group-address (OPTIONAL) Enter the IP multicast group address in dotted decimal format.
Usage Information Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. To enable IGMP snooping, enter this command.
Version Description E-Series legacy command. Usage Information Queriers normally send some queries when a leave message is received prior to deleting a group from the membership database. There may be situations when you require a fast deletion of a group. When you enable IGMP fast leave processing, the switch removes an interface from the multicast group as soon as it detects an IGMP version 2 leave message on the interface.
ip igmp snooping mrouter Statically configure a VLAN member port as a multicast router interface. Syntax ip igmp snooping mrouter interface interface To delete a specific multicast router interface, use the no igmp snooping mrouter interface interface command. Parameters interface interface Enter the following keywords and slot/port[/subport] or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
ip igmp snooping querier Enable IGMP querier processing for the VLAN interface. Syntax ip igmp snooping querier To disable IGMP querier processing for the VLAN interface, use the no ip igmp snooping querier command. Defaults Not configured. Command Modes INTERFACE VLAN — (conf-if-vl-n) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
detail Command Modes Command History • EXEC • EXEC Privilege • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number.
show ip igmp snooping mrouter Display multicast router interfaces. Syntax show ip igmp snooping mrouter [vlan number] Parameters Command Modes Command History vlan number • EXEC • EXEC Privilege Enter the keyword vlan then the vlan number. The range is from 1 to 4094. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
22 Interfaces The commands in this chapter are supported by Dell Networking operating software on the platform. This chapter contains the following sections: • Basic Interface Commands • Port Channel Commands • Time Domain Reflectometer (TDR) • UDP Broadcast Basic Interface Commands The following commands are for Physical, Loopback, and Null interfaces.
vrrp [[ipv6] vrid] (OPTIONAL) Enter the keyword vrrp to clear the counters of all VRRP groups. To clear the counters of VRRP groups on all IPv6 interfaces, enter ipv6. To clear the counters of a specified group, enter a VRID number from 1 to 255. learning-limit (OPTIONAL) Enter the keywords learning-limit to clear unknown source address (SA) drop counters when MAC learning limit is configured on the interface. vlan vlan-id Enter the keyword vlan followed by the interface VLAN number.
Parameters interface (OPTIONAL) Enter any of the following keywords and slot/port[/subport] or number to clear counters from a specified interface: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Parameters half-life Enter the number of seconds after which the penalty is decreased. The penalty decreases half after the half-life period expires. The range is from 1 to 30 seconds. The default is 5 seconds. reuse-threshold Enter a number as the reuse threshold, the penalty value below which the interface state is changed to “up”. The range is from 1 to 20000. The default is 750.
show interfaces dampening — displays interface dampening information. description Assign a descriptive text string to the interface. Syntax description desc_text To delete a description, use the no description command. Parameters desc_text Enter a text string up to 240 characters long. Defaults none Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
duplex (10/100 Interfaces) Configure duplex mode on any physical interfaces where the speed is set to 10/100. Syntax duplex {half | full} To return to the default setting, use the no duplex command. Parameters half Enter the keyword half to set the physical interface to transmit only in one direction. full Enter the keyword full to set the physical interface to transmit in both directions. Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific.
The threshold commands are supported on S6000 only. To return to the default, use the no flowcontrol rx {off | on}tx {off on} threshold command. Parameters rx on Enter the keywords rx on to process the received flow control frames on this port. rx off Enter the keywords rx off to ignore the received flow control frames on this port. tx on Enter the keywords tx on to send control frames from this port to the connected device when a higher rate of traffic is received.
Can’t configure half duplex when flowcontrol is on, config ignored NOTE: The flow control must be off (rx off tx off) before configuring the half duplex. • Speeds less than 1 Gig cannot be configured when the asymmetric flow control configuration is on. The following erro returned: Can’t configure speed <1G when Asymmetric flowcontrol is on, config ignored • Dell Networking OS only supports rx on tx on and rx off tx off for speeds less than 1 Gig (Symmetric).
off on on Related Commands off on on off on on off on on show running-config — displays the flow configuration parameters (non-default values only). show interfaces — displays the negotiated flow control parameters. interface Configure a physical interface on the switch. Syntax Parameters interface interface range interface range Enter one of the following keywords and slot/port[/subport] or number information: • For a null interface, enter the keyword null then the slot/port information.
Usage Information Version Description 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Introduced You cannot delete a physical interface. By default, physical interfaces are disabled (shutdown) and are not assigned to an IP address or switchport.
Enter the member VLANs using VLAN IDs (separated by commas), a range of VLAN IDs (separated by a hyphen), a single VLAN ID, or a combination. For example: VLAN IDs (comma-separated): 3, 4, 6. Range (hyphen-separated): 5-10. Slot/Port information need not contain a space before and after the dash. For example. both of the following commands are valid: ; ; interface group gigabitethernet 1/1/1 - 5 ; interface group gigabitethernet 1/10/1-5.
Parameters number Enter a number as the interface number. The range is from 0 to 16383. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.11.1 Introduced on the S55, S60, and S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Introduced You cannot delete a Management port. The Management port is enabled by default (no shutdown).
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Introduced Usage Information You cannot delete the Null interface. The only configuration command possible in a Null interface is ip unreachables. Example Dell(conf)#interface null 0 Dell(conf-if-nu-0)# Related Commands interface — configures a physical interface.
Defaults None Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information Only VLAN and port-channel interfaces created using the interface vlan and interface portchannel commands can be used in the interface range command. Use the show running-config command to display the VLAN and port-channel interfaces. VLAN or port-channel interfaces that are not displayed in the show running-config command cannot be used with the bulk configuration feature of the interface range command.
interface, interface,... Enter the keywords interface range and one of the interfaces — slot/port[/ subport], port-channel, or VLAN number. Select the range of interfaces for bulk configuration. You can enter up to six comma-separated ranges. Spaces are not required between the commas. Comma-separated ranges can include VLANs, portchannels, and physical interfaces. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
Dell(config)#interface range macro test Dell(config-if-range-te-1/1/1-3,te-5/1/1-47,te-13/1/1-89)# Related Commands interface range – configures a range of command (bulk configuration) interface range macro name – runs an interface range macro. interface range macro name Run the interface-range macro to automatically configure the pre-defined range of interfaces. Syntax interface range macro name Parameters name Enter the name of an existing macro.
interface vlan Configure a VLAN. You can configure up to 4094 VLANs. Syntax Parameters interface vlan vlan-id [of-instance{of-id}] of-instance{of-id} Enter the keyword of-instance then the OpenFlow instance ID to add the VLAN to the specified OpenFlow instance. The range is from 1 to 8. NOTE: Associate the OpenFlow instance with the VLAN when the VLAN is created. An existing VLAN cannot be associated with an OpenFlow instance.
interface null — configures a null interface. interface port-channel — configures a port channel group. show vlan — displays the current VLAN configuration on the switch. shutdown — disables/enables the VLAN. tagged — adds a Layer 2 interface to a VLAN as a tagged interface. untagged — adds a Layer 2 interface to a VLAN as an untagged interface. intf-type cr4 autoneg Set the interface type as CR4 with auto-negotiation enabled.
keepalive Send keepalive packets periodically to keep an interface alive when it is not transmitting data. Syntax keepalive To stop sending keepalive packets, use the no keepalive command. Defaults Enabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command Modes Command History • EXEC • EXEC Privilege • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example (Single Interface) Key Description T Increase the screen refresh rate. t Decrease the screen refresh rate. q Return to the CLI prompt. systest-3 Monitor time: 00:00:06 Refresh Intvl.
Example (All Interfaces) systest-3 Monitor time: 00:01:31 Refresh Intvl.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. pre-Version 6.2.1.0 Introduced on the E-Series. If the packet includes a Layer 2 header, the difference between the link MTU and IP MTU (ip mtu command) must be enough bytes to include the Layer 2 header. When you enter the no mtu command, Dell Networking OS reduces the IP MTU value to 1536 bytes.
negotiation auto Enable auto-negotiation on an interface. Syntax negotiation auto To disable auto-negotiation, use the no negotiation auto command. Defaults Enabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
• Auto-neg Error — typically indicates that both ends of the node are configured with forced-master or forced-slave. CAUTION: Ensure that one end of your node is configured as forced-master and one is configured as forced-slave. If both are configured the same (that is, forced-master or forced-slave), the show interfaces command flaps between an auto-neg-error and forced-master/slave states. You can display master/slave settings with the show interfaces command.
• Up at 1000 Mb/s • Up at 100 Mb/s • Up at 100 Mb/s • Down • Down * You cannot disable auto-negotiation when the speed is set to 1000 or auto. portmode hybrid To accept both tagged and untagged frames, set a physical port or port-channel. A port configured this way is identified as a hybrid port in report displays. Syntax portmode hybrid To return a port to accept either tagged or untagged frames (non-hybrid), use the no portmode hybrid command.
• False — port is untagged • Hybrid — port accepts both tagged and untagged frames The following describes the interface vlan command shown in the following example. This example shows unconfiguration of the hybrid port using the no portmode hybrid command. NOTE: Remove all other configurations on the port before you can remove the hybrid configuration from the port.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced Usage Information The output of the show interfaces command displays the configured rate interval, along with the collected traffic data.
no shutdown Dell(conf-if-fo-1/4)# show config (for speed) Syntax show config Command Modes INTERFACE MODE Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.1) Introduced on the S6000. Usage Information In order for the speed information corresponding to an interface to appear in the show command output, you must first configure the speed of that interface using the speed command.
Example Version Description 6.1.1.0 Introduced on the E-Series. Dell(conf)#interface range tengigabitethernet 1/1/1 - 1/1/2 Dell(conf-if-range-gi-1/1-1/1/2)#show config ! interface TenGigabitEthernet 1/1/1 no ip address switchport no shutdown ! interface TenGigabitEthernet 1/1/2 no ip address switchport no shutdown Dell(conf-if-range-gi-1/1-1/1/2)# show interfaces Display information on a specific physical interface or virtual interface.
Usage Information Version Description 9.1(0.0) Updated Management Ethernet output to include two global IPv6 addresses on S4810 and Z9000 and added output example showing OpenFlow instance ID. 8.3.12.1 Updated command output to support multiple IPv6 addresses on S4810. 8.3.11.4 Output expanded to support eSR4 optics in Z9000. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.
Line Description unknown”, the Medium and the XFP/SFP receive power reading data might not be present in the output. Interface index... Displays the interface index number the SNMP uses to identify the interface. Internet address... States whether an IP address is assigned to the interface. If an IP address is assigned, that address is displayed. MTU 1554... Displays link and IP MTU information. LineSpeed Displays the interface’s line speed, duplex mode, and negotiation mode. ARP type:...
Line Description – wred=count both packets discarded in the MAC and in the hardware-based queues Rate information... Estimate of the input and output traffic rate over a designated interval (30 to 299 seconds). Traffic rate is displayed in bits, packets per second, and percent of line rate. Time since... Elapsed time since the last interface status change (hh:mm:ss format).
0 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts 0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts 0 Multicasts, 0 Broadcasts 0 runts, 0 giants, 0 throttles 0 CRC, 0 overrun, 0 discarded Output Statistics: 0 packets, 0 bytes, 0 underruns 0 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts 0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts 0 Multicasts, 0 Broadcasts, 0 Unicasts 0 Vlans, 0 throttles, 0 discarded, 0 collisions, 0 wreddrops Rate info (interval 299 s
MTU 1554 bytes, IP MTU 1500 bytes LineSpeed 1000 Mbit, Mode full duplex ARP type: ARPA, ARP Timeout 04:00:00 Last clearing of "show interface" counters 00:06:14 Queueing strategy: fifo Input 791 packets, 62913 bytes, 775 multicast Received 0 errors, 0 discarded Output 21 packets, 3300 bytes, 20 multicast Output 0 errors, 0 invalid protocol Time since last interface status change: 00:06:03 Example (OpenFlow instance) Dell#show interfaces vlan 6 Vlan 6 is down, line protocol is down Address is 00:01:e8:8a:e1
show interfaces configured Display any interface with a non-default configuration. Syntax show interfaces configured Command Modes Command History • EXEC • EXEC Privilege Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.
show interfaces dampening Display interface dampening information. Syntax Parameters show interfaces dampening [[interface] [summary] [detail]] interface (Optional) Enter one of the following keywords and slot/port[/subport] or number information: • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
Te 3/10/1 Dell# Related Commands Up 0 0 5 750 2500 20 dampening — configures dampening on an interface. show interfaces — displays information on a specific physical interface or virtual interface. show interfaces configured — displays any interface with a non-default configuration. show interfaces stack-unit Display information on all interfaces on a specific S-Series or Z-Series stack member.
Output Statistics: 0 packets, 0 bytes, 0 underruns 0 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts 0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts 0 Multicasts, 0 Broadcasts, 0 Unicasts 0 throttles, 0 discarded, 0 collisions Rate info (interval 299 seconds): Input 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate Output 00.00 Mbits/sec, 0 packets/sec, 0.
Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series.
Address is 90:b1:1c:f4:99:ce, Current address is 90:b1:1c:f4:99:ce Interface index is 1107787786 Internet address is not set Mode of IPv4 Address Assignment: NONE DHCP Client-ID: 90b11cf499ce MTU 1554 bytes, IP MTU 1500 bytes LineSpeed auto ARP type: ARPA, ARP Timeout 04:00:00 Last clearing of "show interface" counters 2d17h26m Queueing strategy: fifo Time since last interface status change: 2d17h26m Input Statistics: 0 packets, 0 bytes Output Statistics: 0 packets, 0 bytes, 0 underruns Related Commands sh
Dell(conf)#00:02:24: %STKUNIT1-M:CP %IFMGR-5-DYNAMIC_FANOUT: Port 24 in slot 1 has been fanned-out >>>>> Dell(conf)#00:02:27: %S6000-ON:1 %IFAGT-5-INSERT_OPTICS_QSFP: Optics QSFP inserted in slot 1 port 24/2 00:02:27: %S6000-ON:1 %IFAGT-5-INSERT_OPTICS_QSFP: Optics QSFP inserted in slot 1 port 24/3 i00:02:27: %S6000-ON:1 %IFAGT-5-INSERT_OPTICS_QSFP: Optics QSFP inserted in slot 1 port 24/4 Related Commands stack-unit portmode — splits a single 40G port into four-10G ports stack-unit quad-port-profile Conf
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.
Vlan membership: Vlan 2 --More-Related Commands interface — configures a physical interface on the switch. show ip interface — displays Layer 3 information about the interfaces. show interfaces — displays information on a specific physical interface or virtual interface. show interfaces transceiver — displays the physical status and operational status of an installed transceiver. The output also displays the transceiver’s serial number.
Usage Information The following describes the show interfaces transceiver command shown in the following example. Line Description Rx Power measurement type Output depends on the vendor, typically either “Average” or “OMA” (Receiver optical modulation amplitude). Temp High Alarm threshold Factory-defined setting, typically in Centigrade. Value differs between SFPs and SFP+. Voltage High Alarm threshold Displays the interface index number used by SNMP to identify the interface.
Interfaces Line Description Power Low Warning threshold Factory-defined setting. Value can differ between SFP and SFP+. Temperature Current temperature of the SFPs. If this temperature crosses Temp High alarm/ warning thresholds, the temperature high alarm/warning flag is set to true. Voltage Current voltage of the SFPs. If this voltage crosses voltage high alarm/warning thresholds, the voltage high alarm/warning flag is set to true.
Example Line Description Tx Bias Low Alarm Flag This can be either true or false, depending on the Tx bias current value displayed above. Tx Power Low Alarm Flag This can be either true or false, depending on the Current Tx power value displayed above. Rx Power Low Alarm Flag This can be either true or false, depending on the Current Rx power value displayed above. Temperature High Warning Flag This can be either true or false, depending on the Current Temperature value displayed above.
SFP 1 Diagnostic Information =================================== SFP 1 Rx Power measurement type = Average =================================== SFP 1 Temp High Alarm threshold = 95.000C SFP 1 Voltage High Alarm threshold = 3.900V SFP 1 Bias High Alarm threshold = 17.000mA SFP 1 TX Power High Alarm threshold = 0.631mW SFP 1 RX Power High Alarm threshold = 1.259mW SFP 1 Temp Low Alarm threshold = -25.000C SFP 1 Voltage Low Alarm threshold = 2.700V SFP 1 Bias Low Alarm threshold = 1.
show range Display all interfaces configured using the interface range command. Syntax show range Command Modes INTERFACE RANGE (config-if-range) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.
1000 Enter the keyword 1000 to set the interface to auto-negotiate its speed. auto Enter the keyword auto to set the interface to auto-negotiate its speed. Defaults auto Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for dynamically fanning-out of interfaces on S6000. Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.
Parameters backup interface Use this option to configure a redundant Layer 2 link without using Spanning Tree. The keywords backup interface configures a backup port so that if the primary port fails, the backup port changes to the up state. If the primary later comes up, it becomes the backup. tengigabit Enter the keyword tengigabit if the backup port is a 10G port. fortyGigE Enter the keyword fortyGigE if the backup port is a 40G port.
Port Channel Commands A Link Aggregation Group (LAG) is a group of links that appear to a MAC client as if they were a single link according to IEEE 802.3ad. In Dell Networking OS, a LAG is referred to as a Port Channel. • For the S-Series and Z9000, the maximum port channel ID is 128 and the maximum members per port channel is 16.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-Version 6.2.1.0 Introduced on the E-Series. Use the interface port-channel command to access this command. You cannot add an interface to a Port Channel if the interface contains an IP address in its configuration. Only the shutdown, description, mtu, and ip mtu commands can be configured on an interface if it is added to a Port Channel.
To remove an existing LAG supergroup, use the no group group_number command. Parameters group_number Enter an integer from 1 to 32 that uniquely identifies this LAG fate-sharing group. port-channel number Enter the keywords port-channel then an existing LAG number. Enter this keyword/variable combination twice, identifying the two paired LAGs. Defaults none Command Modes PORT-CHANNEL FAILOVER-GROUP (conf-po-failover-grp) Command History This guide is platform-specific.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. Version 9.0.2.0 Introduced on the S6000. Version 8.3.19.0 Introduced on the S4820T. Version 8.3.12.0 Introduced on S4810. Version 8.3.11.1 Introduced on Z9000. Version 8.1.1.0 Introduced on E-Series ExaScale. Version 7.6.1.0 Introduced on S-Series. Version 7.5.1.0 Introduced on C-Series. pre-Version 6.2.1.0 Introduced on E-Series.
minimum-links Configure the minimum number of links in a LAG (Port Channel) that must be in “oper up” status for the LAG to be also in “oper up” status. Syntax minimum-links number Parameters number Enter the number of links in a LAG that must be in “oper up” status. The range is from 1 to 16. The default is 1. Defaults 1 Command Modes INTERFACE Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. Modified to display the LAG failover group status. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information 634 Interfaces The following describes the show interfaces port-channel command shown in the following example.
Example Field Description Time since... Displays the time since the last change in the configuration of this interface. Dell#show interfaces port-channel 20 Port-channel 20 is up, line protocol is up (Failover-group 1 is down) Hardware address is 00:01:e8:01:46:fa Port-channel is part of failover-group 1 Internet address is 1.1.120.
1 L2 up 00:00:08 Dell# Related Commands Te 3/1/1 (Up) * Te 3/2/1 (Down) Te 3/3/1 (Up) show lacp — displays the LACP matrix. show port-channel-flow Display an egress port in a given port-channel flow.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. Because this command calculates based on a Layer 2 hash algorithm, use this command to display flows for switched Layer 2 packets, not for routed packets (use the show ip flow command to display routed packets).
Syntax ip http source-interface interface To delete an interface, use theno ip http source-interface interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
23 IPv4 Routing The basic IPv4 commands are supported by Dell Networking operating system on the platform. arp To associate an IP address with a MAC address in the switch, use address resolution protocol (ARP). Syntax arp [vrf vrf-name] ip-address mac-address interface To remove an ARP address, use the no arp ip-address command. Parameters vrf vrf-name Enter a VRF name to configure an ARP entry for that VRF. Use the VRF option after the keyword arp to configure a static arp on that particular VRF.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. You cannot use Class D or Class E IP addresses or zero IP address (0.0.0.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810. Usage Information This timer is an exponential backoff timer. Over the specified period, the time between ARP requests increases. This behavior reduces the potential for the system to slow down while waiting for a multitude of ARP responses. Related Commands show arp retries — displays the configured number of ARP retries.
arp max-entries Enables you to configure the maximum number of ARP entries per VRF that are allowed for IPv4.. Syntax arp max-entries [vrf vrf-name] max-number Parameters vrf vrf-name Enter the name of a specific VRF for which you want to configure maximum number of ARP entries that IPv4 allows. max-number Enter the maximum number of ARP entries that a VRF RTM can hold. The range is from 0 to 65535. Defaults Not configured.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced. Usage Information Retries are 20 seconds apart. Related Commands show arp retries — displays the configured number of ARP retries. arp timeout Set the time interval for an ARP entry to remain in the ARP cache. Syntax Parameters arp timeout minutes minutes Enter the number of minutes. The range is from 0 to 35790.
clear arp-cache Clear the dynamic ARP entries from a specific interface or optionally delete (no-refresh) ARP entries from the content addressable memory (CAM). Syntax clear arp-cache [vrf vrf-name | interface | ip ip-address] [no-refresh] Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to clear the ARP cache corresponding to that VRF.
Version Description 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. clear host Remove one or all dynamically learned host table entries. Syntax Parameters clear host name name Enter the name of the host to delete. Enter * to delete all host table entries.
Parameters unit-number Enter the number of the stack unit. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to clear all FIB entries corresponding to that VRF. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. Use the vrf vrf-name attribute of this command to clear routes corresponding to either a specific VRF or the default VRF.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. debug arp View information on ARP transactions. Syntax debug arp [interface] [count value] To stop debugging ARP transactions, use the no debug arp command.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.10 Introduced on the E-Series. Example Dell#debug ip dhcp 00:12:21 : %RELAY-I-PACKET: BOOTP REQUEST (Unicast) received at interface 113.3.3.17 BOOTP Request, hops = 0, XID = 0xbf05140f, secs = 0, hwaddr = 00:60:CF:20:7B:8C, giaddr = 0.0.0.0 00:12:21 : %RELAY-I-BOOTREQUEST: Forwarded BOOTREQUEST for 00:60:CF:20:7B: 8C to 14.4.4.
To disable debugging, use the no debug ip icmp command. Parameters interface count value (OPTIONAL) Enter the following keywords and slot/port[/subport] or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Usage Information To stop packets from flooding the user terminal when debugging is turned on, use the count option. debug ip packet View a log of IP packets sent and received. Syntax debug ip packet [access-group name] [count value] [interface] To disable debugging, use the no debug ip packet [access-group name] [count value] [interface] command.
Usage Information Example Version Description 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Added the access-group option. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Added the count option. The following describes the debug ip packet command in the following example.
IP: s=0.0.0.0, d=30.30.30.30, len 100, unroutable ICMP type=8, code=0 Usage Information To stop packets from flooding the user terminal when debugging is turned on, use the count option. The access-group option supports only the equal to (eq) operator in TCP ACL rules. Port operators not equal to (neq), greater than (gt), less than (lt), or range are not supported in access-group option (refer to the following example).
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. ip domain-list Configure names to complete unqualified host names. Syntax ip domain-list name To remove the name, use the no ip domain-list name command. Parameters name Enter a domain name to be used to complete unqualified names (that is, incomplete domain names that cannot be resolved). Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
To view current bindings, use the show hosts command. To view a DNS-related configuration, use the show running-config resolve command. Related Commands ip domain-name — specifies a DNS server. ip domain-lookup To address resolution (that is, DNS), enable dynamic host-name. Syntax ip domain-lookup To disable DNS lookup, use the no ip domain-lookup command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
ip domain-name Configure one domain name for the switch. Syntax ip domain-name name To remove the domain name, use the no ip domain-name command. Parameters name Enter one domain name to be used to complete unqualified names (that is, incomplete domain names that cannot be resolved). Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
ip helper-address Specify the address of a DHCP server so that DHCP broadcast messages can be forwarded when the DHCP server is not on the same subnet as the client. Syntax ip helper-address ip-address To remove a DHCP server address, use the no ip helper-address command. Parameters ip-address Enter an IP address in dotted decimal format (A.B.C.D). Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific.
ip helper-address hop-count disable Disable the hop-count increment for the DHCP relay agent. Syntax ip helper-address hop-count disable To re-enable the hop-count increment, use the no ip helper-address hop-count disable command. Defaults Enabled; the hops field in the DHCP message header is incremented by default. Command Modes CONFIGURATION Command History This guide is platform-specific.
To remove an IP host, use the no ip host name [ip-address] command. Parameters name Enter a text string to associate with one IP address. ip address Enter an IP address, in dotted decimal format, to be mapped to the name. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Not configured. Command Modes CONFIGURATION Command History Usage Information • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.
NOTE: When you configure the capability to enable the loopback IP address to be sent for easy debugging and diagnosis (IP addresses of the devices for which the ICMP source interface is configured), the source IP address of the outgoing ICMP error message is modified, although the packets are not sent out using the configured interface.
ip max-frag-count Set the maximum number of fragments allowed in one packet for packet re-assembly. Syntax ip max-frag-count count To place no limit on the number of fragments allowed, use the no ip max-frag-count command. Parameters count Enter a number for the number of fragments allowed for re-assembly. The range is from 2 to 256. Defaults No limit is set on number of fragments allowed. Command Modes CONFIGURATION Command History This guide is platform-specific.
ipv4-address2... ipv4-address6 (OPTIONAL) Enter up five more IPv4 addresses, in dotted decimal format, of name servers to be used. Separate the addresses with a space. Defaults No name servers are configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. show ip interface — displays the interface routing status and configuration. ip route Assign a static route to the switch.
• For a tunnel interface, enter the keyword tunnel then the tunnel interface number. The range is from 1 to 16383. If you configure a static IPv6 route using an egress interface and enter the ping command to reach the destination IPv6 address, the ping operation may not work. Configure the IPv6 route using a next-hop IPv6 address in order for the ping command to detect the destination address. interface ip-address Enter the keyword interface then the IP address.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Using the following example of a static route: ip route 33.33.33.0 /24 tengigabitethernet 1/1 172.31.5.43 • The software installs a next hop that is not on the directly connected subnet but which recursively resolves to a next hop on the interface’s configured subnet. In the example, if tengig 1/1 has an ip address on subnet 2.2.2.0 and if 172.31.5.
Defaults Enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.
ip unknown-unicast Enable IPv4 catch-all route. Syntax ip unknown-unicast To remove the IPv4 catch-all route (0.0.0.0/0) from the LPM route forwarding table in hardware which gets added as a default configuration after the initialization of FIB Agent module, use the no ip unknownunicast command. Defaults None Parameters Command Modes Command History Usage Information vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to enable catch-all routes corresponding to that VRF.
route prefixes are cleared from RTM Dell(conf)#no ip unicast-host-route show ip tcp initial-time Displays the interval that you configured for the device to wait before the TCP connection is attempted to be established. Syntax show ip tcp initial-time Command Modes EXEC EXEC Privilege Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL platforms.
Version Description 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. load-balance By default, for C-Series and S-Series, Dell Networking OS uses an IP 4-tuple (IP SA, IP DA, Source Port, and Destination Port) to distribute IP traffic over members of a Port Channel as well as equal-cost paths. To designate another method to balance traffic over Port Channel members, use the load-balance command.
Defaults IP 4-tuple (IP SA, IP DA, Source Port, Destination Port) Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
port | L4-destport ] mac [source-mac | source-port-id | source-module-id | dest-mac | destport-id | destmodule-id | vlan | ethertype | sourcedest-mac ] tunnel [ipv4-overipv4 | ipv4-overgre-ipv4 | mac-inmac]} • dest-port-id — Use dest-port-id field in hash calculation. • dest-module-id — Use dest-module-id field in hash calculation. • protocol — Use IPv4 protocol field in hash calculation. • vlan — Use vlan field in hash calculation.
management route Configure a static route that points to the Management interface or a forwarding router. Syntax management route {{ip-address mask | {ipv6-address prefix-length}} {forwarding-router-address | managementethernet | fortyGigE | vlan | tengigabitethernet} To remove a static route, use the no management route{{ip-address mask | {ipv6-address prefix-length}}{forwarding-router-address | managementethernet | fortyGigE | vlan | gigabitethernet | tengigabitethernet} command.
Version Description pre-6.1.1.0 Introduced on the E-Series. Usage Information When a static route (or a protocol route) overlaps with Management static route, the static route (or a protocol route) is preferred over the Management Static route. Also, Management static routes and the Management Connected prefix are not reflected in the hardware routing tables. Separate routing tables are maintained for IPv4 and IPv6 management routes. This command manages both tables.
macaddress macaddress mask (OPTIONAL) Enter the keyword macaddress then a MAC address in nn:nn:nn:nn:nn:nn format. Enter the optional MAC address mask in nn:nn:nn:nn:nn format also. static (OPTIONAL) Enter the keyword static to view entries entered manually. retries (OPTIONAL) Enter the keyword retries to show the number of ARP retries before a 20–second back off. dynamic (OPTIONAL) Enter the keyword dynamic to view dynamic entries.
Description Example Age(min) Displays the age (in minutes) of the ARP entry. Hardware Address Displays the MAC address associated with the ARP entry. Interface Displays the first two letters of the interfaces type and the slot/port associated with the ARP entry. VLAN Displays the VLAN ID, if any, associated with the ARP entry. CPU Lists which CPU the entries are stored on.
switchport mode private-vlan — sets PVLAN mode of the selected port. show arp retries Display the configured number of ARP retries. Syntax Command Modes Command History show arp retries • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Added support for IPv6 addresses. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. The following describes the show hosts command in the following example. Field Description Default domain...
Z10-3 Dell# Related Commands (perm, OK) - IP 192.71.23.1 traceroute — views the DNS resolution. ip host — configures a host. show ip cam stack-unit Display CAM entries for a port-pipe of a stack-unit on a S-Series or Z-Series switch. Syntax Parameters show ip cam stack-unit {stack-unit-number} [port-set {pipe-number} {ip-address mask [longer-prefixes [ecmp-group detail]]}| ecmp-group {detail | member-info [detail [gr index index-number]]}| summary] stack-unit-number Enter the stack-unit ID.
Usage Information Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Added support for up to seven stack members. 7.6.1.0 Introduced on the S-Series. The following describes the show ip cam command shown in the following example. Field Description Destination Displays the destination route of the index. EC Displays 1 if the route is an ECMP route. Else, displays 0. C This is the CPU bit.
show ip fib stack-unit View all Forwarding Information Base (FIB) entries of a specific stack-unit. Syntax Parameters Command Modes Command History show ip fib stack-unit id vrf vrf-name [ip-address [mask] [longer-prefixes] | summar id Enter the S-Series stack unit ID. The unit ID range is from 1 to 6.
If weighted ECMP is enabled, then the show ip fib stack-unit command display a new column named W-EC (W displays either a value of 1 or 0 depending on whether or not a route is assigned with a weight. Example Dell#show ip fib stack-unit 1 Destination Gateway First-Hop Mac-Addr Port VId -----------------------------------------------------------------------------------1.1.1.2/32 via 1.1.1.2, Vl 1000 1.1.1.2 00:01:00:00:00:02 Te 3/12/1 1000 2.1.1.2/32 via 2.1.1.2, Vl 20 2.1.1.2 00:03:00:00:00:02 Po 10 20 0.
destination-ip address Enter the keywords destination-ip then the IP destination address in IP address format. protocol number [tcp | udp] Enter the keyword protocol then one of the protocol type keywords: tcp, udp, or protocol number The protocol number range is from 0 to 255. . src-port number Enter the keywords src-port then the source port number. destination-port number Enter the keywords destination-port then the destination port number.
show ip interface View IP-related information on all interfaces. Syntax show ip interface [interface | brief] [configured] Parameters interface (OPTIONAL) Enter the following keywords and slot/port[/subport] or number information: Command Modes Command History • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Usage Information Example Version Description 8.1.1.2 Supported on the E-Series ExaScale E600i. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. The following describes the show ip interface command shown in the following example. Lines Description TenGigabitEthernet 1/1... Displays the interface’s type, slot/port/subport, and physical and line protocol status. Internet address...
Example (Brief) Dell#show ip interface brief Interface IP-Address Protocol TenGigabitEthernet 1/1/1 unassigned down TenGigabitEthernet 1/1/2 unassigned down TenGigabitEthernet 1/1/3 unassigned TenGigabitEthernet 1/1/4 unassigned TenGigabitEthernet 1/2/1 unassigned TenGigabitEthernet 1/2/2 10.10.10.
Example Version Description pre-6.1.1.0 Introduced on the E-Series. Dell#show ip management-route Destination ----------10.1.2.0/24 172.16.1.0/24 Dell# Gateway ------ManagementEthernet 1/1 10.1.2.4 State ----Connected Active show ipv6 management-route Display the IPv6 static routes configured for the management interface.
2001:68::0/64 Dell# 2001:34::16 Active show ip protocols View information on all routing protocols enabled and active on the switch. Syntax show ip protocols Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example 690 Version Description 9.7(0.
show ip route View information, including how they were learned, about the IP routes on the switch. Syntax Parameters show ip route [vrf vrf-name] hostname | ip-address [mask] [longer-prefixes] | list prefix-list | protocol [process-id | routing-tag] | all | connected | static | summary] vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the VRF name to list the routes in the route table of a specific VRF.
The following is a list of the Dell Networking OS version history for this command. Usage Information 692 IPv4 Routing Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.
Field Description Last Change Identifies when the route was last changed or configured. The weight for weighted ECMP route calculations is displayed for each path in the route in show ip route command. The ECMP weight is displayed only if weighted ECMP is enabled using the ip ecmp weighted command is enabled. If weighted ECMP is disabled, the show ip route command does not show the weighted ECMP route information.
----------------- ----------S 1.1.1.0/24 100 C 4.4.4.0/24 1/4/1 00:01:32 C 6.6.6.0/24 1/16/1 00:01:25 4.4.4.2, via Te 1/4/1 , weight 1/0 00:00:01 6.6.6.2, via Te 1/16/1, Direct, Te Direct, Te weight 200 0/0 0/0 Dell# show ip route 1.1.1.0/24 Routing entry for 1.1.1.0/24 Known via "static", distance 1, metric 0 Last update 00:05:01 ago Routing Descriptor Blocks: * 4.4.4.2, via TenGigabitEthernet 1/4/1 weight 100 * 6.6.6.
show ip route list Display IP routes in an IP prefix list. Syntax Parameters Command Modes Command History show ip route vrf vrf-name list prefix-list prefix-list Enter the name of a configured prefix list. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to display IP routes in an IP prefix list corresponding to that VRF. • EXEC • EXEC Privilege This guide is platform-specific.
Related Commands ip prefix-list — enters CONFIGURATION-IP PREFIX-LIST mode and configures a prefix list. show ip prefix-list summary — displays a summary of the configured prefix lists. show ip route summary View a table summarizing the IP routes in the switch. Syntax show ip route vrf vrf-name summary Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Column Heading Description Total 1388 active... Example Displays the number of active and non-active routes and the memory usage of those routes. If there are no routes configured in the Dell Networking OS, this line does not appear.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 F10 Monitoring MIB available for the ip traffic statistics command. pre-6.1.1.0 Introduced on the E-Series. The following describes the show ip traffic summary shown in the following example.
Example • IP Statistics: Bcast: Sent: Object = f10BcastPktSent, OIDs = 1.3.6.1.4.1.6027.3.3.5.1.2 • IP Statistics: Mcast: Received: Object = f10McastPktRecv, OIDs = 1.3.6.1.4.1.6027.3.3.5.1.3 • IP Statistics: Mcast: Sent: Object = f10McastPktSent, OIDs = 1.3.6.1.4.1.6027.3.3.5.1.4 • ARP Statistics: Rcvd: Request: Object = f10ArpReqRecv, OIDs = 1.3.6.1.4.1.6027.3.3.5.2.1 • ARP Statistics: Rcvd: Replies: Object = f10ArpReplyRecv, OIDs = 1.3.6.1.4.1.6027.3.3.5.2.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 6.4.1.
Example Field Description 11603 data packets... Displays the number of data packets sent. 24 data packets retransmitted Displays the number of data packets resent. 355 ack.. Displays the number of acknowledgement packets sent and the number of packet delayed. 0 window probe... Displays the number of window probe and update packets sent. 7 Connections initiated... Displays the number of TCP connections initiated, accepted, and established. 14 Connections closed...
24 IPv6 Basics IPv6 basic commands are supported on the Dell Networking OS. NOTE: For information about the Dell Networking operating software version and platform that supports IPv6 in each software feature, refer to the IPv6 Addressing chapter of the Dell Networking OS Configuration Guide. cam-ipv6 extended-prefix Enable LPM partitioning to support IPv6 /65 to /128 route prefixes to be stored in Partition 1.
Parameters vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to clear the IPv6 routes corresponding to that VRF. * Enter the * to clear (refresh) all routes from the IPv6 routing table. ipv6-address prefixlength Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros.
warning-only When the warning-only option is used, a syslog message will be thrown when maximum number of dynamic IPv6 routes reaches the limit. Additional dynamic IPv6 routes will still be allowed. Defaults No limit is set on the maximum number of dynamic IPv6 routes for a VRF. Command Modes CONFIGURATION-VRF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OSCommand Line Reference Guide.
ipv6 unicast-host-route Enable programming of IPv6 /128 route prefixes in L3 host table. Syntax [no] ipv6 unicast-host-route Defaults Enabled by default. By default, all the IPv6/128 route prefixes are installed only in L3 host table. Command Modes CONFIGURATION Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.1) Introduced on the S6000. Usage Information You can use this command to enable programming of /128 route prefixes in L3 host table or in LPM table.
Command Modes Command History INTERFACE CONFIG Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.0) Introduced on the Z9000, S6000, S4810, S4820T, and MXL.. Usage Information Use this command to add, edit, or delete an IPv6 RDNSS address and lifetime value. You can configure up to four IPv6 RDNSS addresses. You must specify a lifetime using the lifetime or infinite parameter. Example Dell(conf-if-te-1/1/1)#ipv6 nd dns-server 1000::1 1 ipv6 route Establish a static IPv6 route.
Configure the IPv6 route using a next-hop IPv6 address in order for the ping command to detect the destination address. ipv6-address (OPTIONAL) Enter the forwarding router IPv6 address in the x:x:x:x::x format. NOTE: The :: notation specifies successive hexadecimal fields of zeros. distance (OPTIONAL) Enter a number as the metric distance assigned to the route. The range is from 1 to 255. tag value (OPTIONAL) Enter the keyword tag then a tag value number. The range is from 1 to 4294967295.
You can specify a weight for an IPv4 or IPv6 static route. If the weight value of a path is 0, then that path is not used for forwarding when weighted ECMP is in effect. Also, if a path corresponding to a static route (destination) has a non-zero weight assigned to it and other paths do not have any weight configured, then regular ECMP is used for forwarding. You can specify the weight value only to destination address and not on the egress port.
summary Defaults Command Modes Command History (OPTIONAL) View a brief list of the configured IPv6 routes. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for VRF. Introduced on S6000–ON 9.0.0.0 Introduced on the Z9000.
Field Description • Example (S-Series) + = summary routes Destination Identifies the route’s destination IPv6 address. Gateway Identifies whether the route is directly connected and on which interface the route is configured. Dist/Metric Identifies if the route has a specified distance or metric. Last Change Identifies when the route was last changed or configured.
Total 4 active route(s) using 928 bytes Dell# IPv6 Basics 711
25 IPv6 Access Control Lists (IPv6 ACLs) IPv6 ACLs and IPv6 Route Map commands are supported on Dell Networking platform. NOTE: For IPv4 ACL commands, refer to the Access Control Lists (ACL) chapter. Important Points to Remember • Certain platforms require manual CAM usage space allotment. For more information, refer to the cam-acl command. • Egress IPv6 ACL and IPv6 ACL on the Loopback interface is not supported. • Reference to an empty ACL permits any traffic.
Example Version Description 8.3.7.0 Introduced on the S4810. 8.4.2.1 Introduced on the S-Series. 8.4.2.0 Introduced on the E-Series TeraScale. 7.8.1.0 Introduced on the C-Series. Dell#show cam-acl-egress -- Chassis Egress Cam ACL -Current Settings(in block sizes) L2Acl : 1 Ipv4Acl : 1 Ipv6Acl : 2 -- Stack unit 1 -Current Settings(in block sizes) L2Acl : 1 Ipv4Acl : 1 Ipv6Acl : 2 Dell#show cam-acl Related Commands cam-acl — configures CAM profiles to support IPv6 ACLs.
Example Version Description 7.8.1.0 Introduced on the C-Series.
L2Qos : 3 Dell#show cam-acl Related Commands cam-acl — configures CAM profiles to support IPv6 ACLs. permit icmp To allow all or specific internet control message protocol (ICMP) messages, configure a filter. Syntax permit icmp {source address mask | any | host ipv6-address} {destination address | any | host ipv6-address} [count [byte]] To remove this filter, you have two choices: • Use the no seq sequence-number command if you know the filter’s sequence number.
To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command syntax if you know the filter’s sequence number • Use the no permit {ipv6-protocol-number | icmp | ipv6 | tcp | udp} command ip-protocol-number Enter an IPv6 protocol number. The range is from 0 to 255. icmp Enter the keyword icmp to filter internet Control Message Protocol version 6. ipv6 Enter the keyword ipv6 to filter any internet Protocol version 6.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. ipv6 access-list Configure an access list based on IPv6 addresses or protocols. Syntax ipv6 access-list access-list-name cpu-qos {permit | deny} ospfv3 To delete an access list, use the no ipv6 access-list access-list-name command. Parameters access-list-name Enter the access list name as a string, up to 140 characters.
Usage Information Version Description 7.4.1.0 Introduced on the E-Series TeraScale. The number of entries allowed per ACL is hardware-dependent. For detailed specification on entries allowed per ACL, refer to your line card documentation. You can create an IPv6 ACL for control-plane traffic policing for OSPFv3, in addition to the CoPP support for VRRP, BGP, and ICMP. cam-acl-egress Allocate space for IPv6 egress ACLs.
Example Dell# Dell#configure Dell(conf)#cam-acl-egress ? default Reset Egress CAM ACL entries to default setting l2acl Set L2-ACL entries Dell(conf)#cam-acl-egress l2acl ? <1-4> Number of FP blocks for l2acl Dell(conf)#cam-acl-egress l2acl 1 ? ipv4acl Set IPV4-ACL entries Dell(conf)#cam-acl-egress l2acl 1 ipv4acl 1 ? ipv6acl Set IPV6-ACL entries Dell(conf)#cam-acl-egress l2acl 1 ipv4acl 1 ipv6acl ? <0-4> Number of FP blocks for IPV6 (multiples of 2) Dell(conf)#cam-acl-egress l2acl 1 ipv4acl 1 ipv6acl 2 ca
Usage Information Version Description 8.4.2.0 Introduced on the E-Series TeraScale. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series. For the new settings to take effect, save the new CAM settings to the startup-config (write-mem or copy run start), then reload the system. The total amount of space allowed is 16 FP blocks. System flow requires three blocks and these blocks cannot be reallocated. When configuring space for IPv6 ACLs, the total number of Blocks must equal 13.
26 Intermediate System to Intermediate System (ISIS) The intermediate system to intermediate system (IS-IS) protocol for IPv4 and IPv6 is supported on the S6000–ON platform. IS-IS is an interior gateway protocol that uses a shortest-path-first algorithm. IS-IS facilitates the communication between open systems, supporting routers passing both IP and OSI traffic. A router is considered an intermediate system. Networks are partitioned into manageable routing domains, called areas.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Introduced on the E-Series. To perform protocol-support consistency checks on hello packets, use this command. The adjacency-check is enabled by default. If a BFD session goes down indicating that IPv4 or IPv6 connectivity to its neighbor is lost, it does not imply that the adjacency is lost altogether. The hello adjacency runs over Layer 2, and does not require IP connectivity.
Usage Information Version Description 7.5.1.0 Added IPv6 ISIS support. 6.3.1.0 Version 6.3.1.0 Introduced You cannot disable leaking from Level 1 to Level 2. Also, you cannot enable leaking from Level 2 to Level 1. However, you can regulate the rate flow from one level to another using an IP Prefix list. If you do not configure the IP Prefix list, all Level 1 routes are leaked. You can find more information in IETF RFC 2966, Domain-wide Prefix Distribution with Two-Level IS-IS.
• isis password — allows you to configure an authentication password for an interface. clear config Clear IS-IS configurations that display under the router isis heading of the show running-config command output. Syntax clear config Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
debug isis Enable debugging for all IS-IS operations. Syntax debug isis To disable debugging of IS-IS, use the no debug isis command. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
• For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(0.2) Introduced on the Z9000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 6.3.1.0 Introduced.
Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(0.2) Introduced on the Z9000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 6.3.1.0 Introduced. debug isis spf-triggers Enable debugging on the events that triggered IS-IS shortest path first (SPF) events for debugging purposes. Syntax debug isis [vrf vrf-name] spf-triggers To turn off debugging, use the no debug isis [vrf vrf-name] spf-triggers command.
debug isis update-packets Enable debugging on link state PDUs (LSPs) that a router detects. Syntax debug isis [vrf vrf-name] update-packets [interface] To turn off debugging, use the no debug isis update-packets [interface] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to enable the debugging information on IS-IS. This information contains updates from neighbors tied to the VRF that you specify.
To disable the generation of a default route into the specified IS-IS routing domain, use the no defaultinformation originate [always] [metric metric] [route-map map-name] command. Parameters Defaults Command Modes Command History always (OPTIONAL) Enter the keyword always to have the default route always advertised. metric metric (OPTIONAL) Enter the keyword metric then a number to assign to the route. The range is from 0 to 16777215.
description Enter a description of the IS-IS routing protocol. Syntax description {description} To remove the description, use the no description {description} command. Parameters description Defaults none Command Modes ROUTER ISIS Command History Related Commands Enter a description to identify the IS-IS protocol (80 characters maximum). Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 6.3.1.0 Introduced. The administrative distance indicates the trust value of incoming packets. A low administrative distance indicates a high trust rate. A high value indicates a lower trust rate.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 7.5.1.0 Added IPv6 ISIS support. 6.3.1.0 Introduced. • distribute-list out — suppresses networks from being advertised in updates. • redistribute — redistributes routes from one routing domain to another routing domain. distribute-list out Suppress network prefixes from being advertised in outbound updates.
Usage Information Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 7.5.1.0 Added IPv6 ISIS support. 6.3.1.0 Introduced. You can assign a name to a routing process so a prefix list IS applied to only the routes derived from the specified routing process. • distribute-list in — filters the networks received in updates. • redistribute — redistributes routes from one routing domain to another routing domain.
domain-password Set the authentication password for a routing domain. Syntax domain-password [hmac-md5 | encryption-type] password To disable the password, use the no domain-password command. Parameters hmac-md5 (OPTIONAL) Enter the keywords hmac-md5 to encrypt the password using MD5. encryption-type (OPTIONAL) Enter 7 to encrypt the password using DES. password Enter an alphanumeric string up to 16 characters long.
Defaults Graceful restart disabled. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.
Version Description 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Introduced on the E-Series. graceful-restart restart-wait Enable the graceful restart maximum wait time before a restarting peer comes up. Syntax NOTE: Set the t3 timer to adjacency on the restarting router when implementing this command.
graceful-restart t1 Set the graceful restart wait time before unacknowledged restart requests are generated. This wait time is the interval before the system sends a restart request (an IIH with RR bit set in Restart TLV) until the CSNP is received from the helping router. Syntax graceful-restart t1 {interval seconds | retry-times value} To return to the default, use the no graceful-restart t1 command. Parameters interval Enter the keyword interval to set the wait time.
Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.
Usage Information The running router sets the remaining time value to the current adjacency hold time. You can override this setting by implementing this command. Override the default restart-wait time by entering the no graceful-restart restart-wait command. When you disable restart-wait, the current adjacency hold time is used. Set the t3 timer to adjacency on the restarting router when implementing this command.
hostname dynamic Enables dynamic learning of hostnames from routers in the domain and allows the routers to advertise the hostname in LSPs. Syntax hostname dynamic To disable this command, use the no hostname dynamic command. Defaults Enabled. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. IS-IS normally purges LSPs with an incorrect data link checksum causing the LSP source to regenerate the message. A cycle of purging and regenerating LSPs can occur when a network link continues to deliver accurate LSPs even though there is a link causing data corruption. This process could cause disruption to your system operation.
• router isis — enables the IS-IS routing protocol. ipv6 router isis Enable the IPv6 IS-IS routing protocol and specify an IPv6 IS-IS process. Syntax ipv6 router isis [tag] To disable IS-IS routing, use the no router isis [tag] command. Parameters tag (OPTIONAL) This parameter is a unique name for a routing process. A null tag is assumed if the tag option is not specified. The tag name must be unique for all IP router processes for a given router. Defaults Not configured.
isis circuit-type Configure the adjacency type on interfaces. Syntax isis circuit-type {level-1 | level-1-2 | level-2-only} To return to the default values, use the no isis circuit-type command. Parameters level-1 You can form a Level 1 adjacency if there is at least one common area address between this system and neighbors. You cannot form Level 2 adjacencies on this interface.
Parameters seconds Interval of transmission time between CSNPs on multi-access networks for the designated intermediate system. The range is from 0 to 65535. The default is 10. level-1 (OPTIONAL) Independently configures the interval of time between transmission of CSNPs for Level 1. level-2 (OPTIONAL) Independently configures the interval of time between transmission of CSNPs for Level 2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. Usage Information The holdtime (the product of the hello-multiplier multiplied by the hello-interval) determines how long a neighbor waits for a hello packet before declaring the neighbor is down so routes can be recalculated. Related Commands isis hello-interval — specifies the length of time between hello packets.
To return to the default values, use the no ipv6 isis metric [default-metric] [level-1 | level-2] command. Parameters default-metric Metric assigned to the link and used to calculate the cost from each other router via the links in the network to other destinations. You can configure this metric for Level 1 or Level 2 routing. The range is from 0 to 16777215. The default is 10.
If metric value is configured to more than 63, system throughs the following warning:Warning: for metrics greater than 63, 'metric-style wide' should be configured on level-1-2, or it will be capped at 63. If the metric style is WIDE, the metric values that are greater than 63 are only effective. level-1 (OPTIONAL) Enter the keywords level-1 to configure the shortest path first (SPF) calculation for Level 1 (intra-area) routing. This setting is the default.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. isis password Configure an authentication password for an interface. Syntax isis password [hmac-md5] password [level-1 | level-2] To delete a password, use the no isis password [password] [level-1 | level-2] command. Parameters encryption-type (OPTIONAL) Enter 7 to encrypt the password using DES.
You can assign different passwords for different routing levels by using the keywords level-1 and level-2. The no form of this command disables the password for Level 1 or Level 2 routing, using the respective keywords level-1 or level-2. This password provides limited security as it is processed as plain text. isis priority Set the priority of the designated router you select.
is-type Configure IS-IS operating level for a router. Syntax is-type {level-1 | level-1-2 | level-2-only} To return to the default values, use the no is-type command. Parameters level-1 Allows a router to act as a Level 1 router. level-1-2 Allows a router to act as both a Level 1 and Level 2 router. This setting is the default. level-2-only Allows a router to act as a Level 2 router. Defaults level-1-2 Command Modes ROUTER ISIS Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Added support for LSP Throttling Enhancement. LSP throttling slows down the frequency at which LSPs are generated during network instability.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Added support for LSP Throttling Enhancement. The link MTU and the LSP MTU size must be the same. Because each device can generate a maximum of 255 LSPs, consider carefully whether you use the lspmtu command. lsp-refresh-interval Set the link state PDU (LSP) refresh interval. LSPs must be refreshed before they expire.
The refresh interval must be less than the LSP lifetime specified with the max-lsp-lifetime command. A low value reduces the amount of time that undetected link state database corruption can persist at the cost of increased link utilization. A higher value reduces the link utilization the flooding of refreshed packets causes. Related Commands max-lsp-lifetime — sets the maximum interval that LSPs persist without being refreshed. max-area-addresses Configure manual area addresses.
Parameters seconds The maximum lifetime of LSP in seconds. This value must be greater than the lsp-refresh-interval command. The higher the value the longer the LSPs are kept. The range is from 1 to 65535. The default is 1200. Defaults 1200 seconds Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.8.1.0 Added support for multi-topology ISIS. 6.3.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. If you enter the metric-style wide command, the Dell Networking OS generates and accepts only new-style TLVs. The router uses less memory and other resources rather than generating both old-style and new-style TLVs. The new-style TLVs have wider metric fields than old-style TLVs.
net To configure an IS-IS network entity title (NET) for a routing process, use this mandatory command. If you did not configure a NET, the IS-IS process does not start. Syntax net network-entity-title To remove a net, use the no net network-entity-title command. Parameters network-entity-title Specify the area address and system ID for an IS-IS routing process. The first 1 to 13 bytes identify the area address. The next 6 bytes identify the system ID.
• For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults Not configured. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Defaults Command Modes Command History level-2 (OPTIONAL) Routes are independently redistributed into IS-IS as Level 2 routes. This setting is the default. route-map mapname (OPTIONAL) If you do not enter the route-map argument, all routes are redistributed. If a map-name value is not specified, no routes are imported. • metric metric-value = 0 • metric-type= internal; level-2 • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific.
redistribute bgp Redistribute routing information from a BGP process. Syntax redistribute bgp AS number [level-1| level-1-2 | level-2] [metric metricvalue] [metric-type {external| internal}] [route-map map-name] To return to the default values, use the no redistribute bgp command with the appropriate parameters. Parameters AS number Enter a number that corresponds to the autonomous system number. The range is from 1 to 65355.
Version Description 7.5.1.0 Added support for IPv6 ISIS. 6.3.1.0 Introduced. Usage Information BGP to IS-IS redistribution supports “match” options using route maps. You can set the metric value, level, and metric-type of redistributed routes by the redistribution command. You can “set” more advanced options using route maps.
route-map mapname map-name is an identifier for a configured route map. The route map should filter imported routes from the source routing protocol to the current routing protocol. If you do not specify a map-name, all routes are redistributed. If you specify a keyword, but fail to list route map tags, no routes are imported. Defaults Refer to Parameters.
tag (OPTIONAL) This is a unique name for a routing process. A null tag is assumed if the tag option is not specified. The tag name must be unique for all IP router processes for a given router. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
• Command History CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.
Example (RouterIsis) The bold section identifies that Multi-Topology IS-IS is enabled in Transition mode. Dell(conf-router_isis)#show config ! router isis clns host ISIS 49.0000.0001.F100.E120.0013.00 log-adjacency-changes net 49.0000.0001.F100.E120.0013.
system-id Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Displays the link-state database for system-id. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added supported for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.
Example Field Description ATT This value represents the Attach bit. This value indicates that the router is a Level 1-2 router and can reach other areas. Level 1-only routers and Level 1-2 routers that have lost connection to other Level 1-2 routers use the Attach bit to find the closest Level 1-2 router. They install a default route to the closest Level 1-2 router. P This value represents the P bit. This bit is always set to zero as Dell Networking does not support area partition repair.
Dell#show isis database detail IS-IS Level-1 Link State Database LSPID LSP Seq Num FTOS.00-00 * 0x00000009 NLPID: 0xCC Area Address: 49.0000.0001 LSP Checksum 0x79D8 LSP Holdtime 941 ATT/P/OL 1/0/0 show isis graceful-restart detail Display detailed IS-IS graceful restart related settings.
====================== Current Mode/State T3 Time left T2 Time left Restart ACK rcv count Restart Req rcv count Suppress Adj rcv count Restart CSNP rcv count Database Sync count : : : : : : : : Normal/RUNNING 0 0 (level-1), 0 0 (level-1), 0 0 (level-1), 0 0 (level-1), 0 0 (level-1), 0 0 (level-1), 0 (level-2) (level-2) (level-2) (level-2) (level-2) (level-2) show isis hostname Display IS-IS host names configured or learned on the switch.
show isis interface Display detailed IS-IS interface status and configuration information. Syntax show isis [vrf vrf-name] interface [interface] Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display ISIS interface status information corresponding to that VRF.
Next IS-IS LAN Level-1 Hello in 2 seconds Next IS-IS LAN Level-2 Hello in 1 seconds LSP Interval: 33 TenGigabitEthernet 1/8/1 is up, line protocol is up MTU 1497, Encapsulation SAP Routing Protocol: IS-IS Circuit Type: Level-1-2 Interface Index 38371358, Local circuit ID 2 Level-1 Metric: 10, Priority: 64, Circuit ID: systest-3.02 Hello Interval: 10, Hello Multiplier: 3, CSNP Interval: 10 Number of active level-1 adjacencies: 1 Level-2 Metric: 10, Priority: 64, Circuit ID: systest-3.
Usage Information Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. Use this command to confirm that the neighbor adjacencies are operating correctly. If you suspect that they are not, you can verify the specified area addresses of the routers by using the show isis neighbors command.
show isis protocol Display IS-IS routing information. Syntax Parameters Command Modes Command History show isis [vrf vrf-name] protocol vrf vrf-name • EXEC • EXEC Privilege (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display ISIS routing information corresponding to that VRF. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show isis traffic This command allows you to display IS-IS traffic interface information. Syntax show isis [vrf vrf-name] traffic [interface] Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display ISIS traffic interface information corresponding to that VRF.
Example Item Description Level-1/Level-2 LSPs flooded (sent/rcvd) Displays the number of flooded LSPs sent and received. Level-1/Level-2 LSPs CSNPs (sent/ rcvd) Displays the number of CSNP LSPs sent and received. Level-1/Level-2 LSPs PSNPs (sent/ rcvd) Displays the number of PSNP LPSs sent and received. Level-1/Level-2 DR Elections Displays the number of times designated router elections ran. Level-1/Level-2 SPF Calculations Displays the number of shortest path first calculations.
Defaults level-2 (OPTIONAL) Enter the keyword level-2 to apply the configuration to Level-2 SPF calculations. interval seconds Enter the maximum number of seconds between SPF calculations. The range is from 0 to 120 seconds. The default is 10 seconds. initial_wait_interval seconds (OPTIONAL) Enter the initial wait time, in seconds, before running the first SPF calculations. The range is from 0 to 120 seconds. The default is 5 seconds.
27 Link Aggregation Control Protocol (LACP) This chapter contains commands for Dell Networks’s implementation of the link aggregation control protocol (LACP) for creating dynamic link aggregation groups (LAGs) — known as “port-channels” in the Dell Networking operating software. The LACP commands in this chapter are supported by Dell Networking OS on the S6000–ON platform.
Related Commands Version Description 6.2.1.1 Introduced on the E-Series. show lacp — displays the LACP configuration. debug lacp Debug LACP (configuration, events, and so on). Syntax debug lacp [config | events | pdu [interface-type [in | out]]] To disable LACP debugging, use the no [config | events | pdu [interface-type [in | out]]] command. Parameters config (OPTIONAL) Enter the keyword config to debug the LACP configuration.
Version Description 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. lacp long-timeout Configure a long timeout period (30 seconds) for an LACP session. Syntax lacp long-timeout To reset the timeout period to a short timeout (1 second), use the no lacp long-timeout command.
lacp port-priority To influence which ports will be put in Standby mode when there is a hardware limitation that prevents all compatible ports from aggregating, configure the port priority. Syntax lacp port-priority priority-value To return to the default setting, use the no lacp port-priority priority-value command. Parameters priority-value Enter the port-priority value. The higher the value number, the lower the priority. The range is from 1 to 65535. The default is 32768.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
show lacp Display the LACP matrix. Syntax show lacp port-channel-number [sys-id | counters] Parameters Defaults port-channelnumber Enter a port-channel number. The range is from 1 to 128. sys-id (OPTIONAL) Enter the keywords sys-id and the value that identifies a system. counters (OPTIONAL) Enter the keyword counters to display the LACP counters. Without a Port Channel specified, the command clears all Port Channel counters.
Dell# Example (Sys-id) Oper: State BCEGIKNP Key 1 Priority 128 Dell#show lacp 1 sys-id Actor System ID: Priority 32768, Address 0001.e800.a12b Partner System ID: Priority 32768, Address 0001.e801.
28 Layer 2 This chapter describes commands to configure Layer 2 features. This chapter contains the following sections: • MAC Addressing Commands • Virtual LAN (VLAN) Commands • Far-End Failure Detection (FEFD) The VLAN commands are supported on all the S6000–ON platform. MAC Addressing Commands The following commands are related to configuring, managing, and viewing MAC addresses. mac-address-table aging-time Specify an aging time for MAC addresses to remove from the MAC address table.
Related Commands Version Description 8.3.1.0 On the E-Series, available in INTERFACE VLAN context, reduced the minimum aging time in the INTERFACE VLAN context from 10 seconds to 1 second. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. mac learning-limit — sets the MAC address learning limits for a selected interface. show mac-address-table aging-time — displays the MAC aging time.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Added support for output range parameter for S4810 and Z9000. 8.3.19.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. For details about using this command, refer to the “NIC Teaming” section of the Layer 2 chapter in the Dell Networking OS Configuration Guide. mac learning-limit Limit the maximum number of MAC addresses (static + dynamic) learned on a selected interface.
Usage Information Version Description 8.2.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Added the station-move option. 6.5.1.0 Added support for MAC Learning-Limit on the LAG. This command and its options are supported on physical interfaces, static LAGs, LACP LAGs, and VLANs. If you do not specify the vlan option, the MAC address counters are not VLAN-based.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the S-Series. 7.8.1.
Usage Information If you configure mac-learn-limit and the sticky MAC feature is enabled, dynamically learned MAC addresses are converted to sticky for that port. Any new MAC address that is learned also becomes sticky for that port. Related Commands show mac learning-limit — displays the details of the mac learning-limit. mac learning-limit station-move-violation Specify the actions for a station move violation.
mac learning-limit reset Reset the MAC address learning-limit error-disabled state. Syntax mac learning-limit reset Defaults none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command Modes Command History aging-time Enter the keyword aging-time to display only aging-time information. interface interface (OPTIONAL) Enter the keyword interface then the interface type, slot/port[/ subport] information: • For a port channel interface, enter the keywords port-channel then a number. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
Column Heading Description Type Lists whether the MAC address was manually configured (Static), learned dynamically (Dynamic), or associated with a specific port (Sticky). Interface Displays the interface type and slot/port information. The following abbreviations describe the interface types: State Example Usage Information • gi — Gigabit Ethernet then a slot/port. • po — Port Channel then a number. The range is from 1 to 255 for TeraScale. • te — 10 Gigabit Ethernet then a slot/port.
Static Address (User-defined) Count : 0 Sticky Address Count : 0 Total Synced Mac from Peer(N): 100 Total MAC Addresses in Use: 110 Dell# Related Commands show mac-address-table aging-time — displays MAC aging time. show mac-address-table aging-time Display the aging times assigned to the MAC addresses on the switch.
Parameters Command Modes Command History violate-action (OPTIONAL) Enter the keywords violate-action to display the MAC learning limit violation status. detail (OPTIONAL) Enter the keyword detail to display the MAC learning limit in detail. interface interface (OPTIONAL) Enter the keyword interface with the following keywords and slot/port[/subport] or number information: • EXEC • EXEC Privilege • For a port channel interface, enter the keywords port-channel then a number.
Virtual LAN (VLAN) Commands The following commands configure and monitor virtual LANs (VLANs). VLANs are a virtual interface and use many of the same commands as physical interfaces. You can configure an IP address and Layer 3 protocols on a VLAN called Inter-VLAN routing. FTP, TFTP, ACLs and SNMP are not supported on a VLAN. Occasionally, while sending broadcast traffic over multiple Layer 3 VLANs, the VRRP state of a VLAN interface may continually switch between Master and Backup.
description Add a description about the selected VLAN. Syntax Parameters description description description Defaults none Command Modes INTERFACE VLAN Command History Related Commands Enter a text string description to identify the VLAN (80 characters maximum). Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Usage Information The no default vlan disable command is not listed in the running-configuration, but when the default VLAN is disabled, default-vlan disable is listed in the running-configuration. name Assign a name to the VLAN. Syntax name vlan-name To remove the name from the VLAN, use the no name command. Parameters vlan-name Enter up to 32 characters as the name of the VLAN. Defaults Not configured. Command Modes INTERFACE VLAN Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.1.(0.0) Updated to support OpenFlow. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Column Heading Description Example • Po = port channel • Gi = gigabit Ethernet • Te = ten-gigabit Ethernet Dell#show vlan Codes: * - Default VLAN, G - GVRP VLANs, P - Primary, C - Community, I Isolated Q: U - Untagged, T - Tagged, O - Openflow x - Dot1x untagged, X - Dot1x tagged o - OpenFlow untagged, O - OpenFlow tagged G - GVRP tagged, M - Vlan-stack i - Internal untagged, I - Internal tagged, v - VLT untagged, V - VLT tagged NUM Status Description Q Ports * 1 Inactive 2 Active U Po1(Te 13/1/1) T
x - Dot1x untagged, X - Dot1x tagged G - GVRP tagged, M - Vlan-stack NUM 42 Dell# Status Description Q Ports Active U Te 13/47/1 Example (Brief) Dell#show vlan br VLAN Name STG MAC Aging IP Address ---- -----------------------------------1 0 1800 unassigned 2 0 1800 2.2.2.2/24 3 0 1800 3.3.3.
Command Modes INTERFACE VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Defaults Not configured. Command Modes INTERFACE VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Defaults All interfaces in Layer 2 mode are untagged. Command Modes INTERFACE VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
debug fefd Enable debugging of FEFD. Syntax debug fefd {events | packets} [interface] To disable debugging of FEFD, use the no debug fefd {events | packets} [interface] command. Parameters events Enter the keyword events to enable debugging of FEFD state changes. packets Enter the keyword packets to enable debugging of FEFD to view information on packets sent and received.
Parameters disable Enter the keyword disable to disable FEFD for the specified interface. interval Enter the keyword interval, followed by a value to specify the FEFD interval in seconds. Range is from 3 to 300. Default is 15. mode Enter the keyword mode followed by the mode type to specify the FEFD mode. • normal: Change the link state to “unknown” when a far-end failure is detected by the software on that interface.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Legacy E-Series command.
Version Description Legacy E-Series command. Related Commands • fefd — enables far-end failure detection. fefd mode Change the FEFD mode on an interface. Syntax fefd mode {normal | aggressive}] To return the FEFD mode to the default of normal, use the no fefd mode command. Parameters normal (OPTIONAL) Enter the keyword normal to change the link state to “unknown” when a far-end failure the software detects on that interface.
fefd reset Reset all interfaces or a single interface that was in “error-disabled” mode. Syntax fefd reset [interface] Parameters interface (OPTIONAL) Enter the following keywords and slot/port[/subport] or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Defaults Not configured.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Legacy E-Series command.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. Legacy E-Series command. Usage Information If you enter only the fefd-global syntax, the mode is normal and the default interval is 15 seconds. If you disable FEFD globally (no fefd-global), the system does not remove the FEFD interface configuration. Related Commands • fefd — enables far-end failure detection.
Version Description 8.3.12.0 Introduced on the S4810. Legacy E-Series command. Usage Information Example The following describes the show fefd command shown in the following example. Field Description Interface Displays the interfaces type and number. Mode Displays the mode (aggressive or normal) or NA if the interface contains fefd reset in its configuration. Interval Displays the interval between FEFD packets.
29 Link Layer Discovery Protocol (LLDP) The link layer discovery protocol (LLDP) advertises connectivity and management from the local station to the adjacent stations on an IEEE 802 LAN. This chapter contains the following sections: • LLPD Commands • LLDP-MED Commands LLDP facilitates multi-vendor interoperability by using standard management tools to discover and make available a physical topology for network management.
Command Modes CONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. clear lldp counters Clear LLDP transmitting and receiving counters for all physical interfaces or a specific physical interface.
clear lldp neighbors Clear LLDP neighbor information for all interfaces or a specific interface. Syntax Parameters clear lldp neighbors {interface} interface Defaults none Command Modes EXEC Privilege Command History Enter the following keywords and slot/port[/subport] or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
all (OPTIONAL) Enter the keyword all to display information on all interfaces. events (OPTIONAL) Enter the keyword events to display major events such as timer events. packet (OPTIONAL) Enter the keyword packet to display information regarding packets coming in or going out. brief (OPTIONAL) Enter the keyword brief to display brief packet information. detail (OPTIONAL) Enter the keyword detail to display detailed packet information.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series.
Version Description 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. mode To receive or transmit, set LLDP. Syntax mode {tx | rx} To return to the default, use the no mode {tx | rx} command. Parameters tx Enter the keyword tx to set the mode to transmit. rx Enter the keyword rx to set the mode to receive. Defaults Both transmit and receive.
multiplier Set the number of consecutive misses before LLDP declares the interface dead. Syntax multiplier integer To return to the default, use the no multiplier integer command. Parameters integer Enter the number of consecutive misses before the LLDP declares the interface dead. The range is from 2 to 10. Defaults 4 x hello Command Modes CONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp) Command History This guide is platform-specific.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. protocol lldp (Interface) Enter the LLDP protocol in INTERFACE mode.
show lldp neighbors Display LLDP neighbor information for all interfaces or a specified interface. Syntax Parameters show lldp neighbors [interface] [detail] interface detail (OPTIONAL) Enter the following keywords and slot/port[/subport] or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
show lldp statistics Display the LLDP statistical information. Syntax show lldp statistics Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.
• LLDP-MED Network Connectivity Device — any device that provides access to an IEEE 802 LAN to an LLDP-MED endpoint device, and supports IEEE 802.1AB (LLDP) and TIA-1057 (LLDP-MED). The Dell Networking system is an LLDP-MED network connectivity device.
show lldp neighbors — displays the LLDP neighbors. advertise med guest-voice-signaling To advertise a separate limited voice service for a guest user when the guest voice control packets use a separate network policy than the voice data, configure the system.
advertise med location-identification To advertise a location identifier, configure the system. Syntax advertise med location-identification {coordinate-based value | civic-based value | ecs-elin value} To return to the default, use the no advertise med location-identification {coordinate-based value | civic-based value | ecs-elin value} command. Parameters coordinate-based value Enter the keywords coordinate-based then the coordinated based location in hexadecimal value of 16 bytes.
advertise med power-via-mdi To advertise the Extended Power via MDI TLV, configure the system. Syntax advertise med power-via-mdi To return to the default, use the no advertise med power-via-mdi command. Defaults unconfigured. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
priority-tagged number Enter the keywords priority-tagged then the Layer 2 priority. The range is from 0 to 7. Defaults unconfigured. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series and E-Series. debug lldp interface — debugs LLDP. show lldp neighbors — displays the LLDP neighbors. advertise med video-signaling To advertise video control packets that use a separate network policy than video data, configure the system.
Related Commands Version Description 7.6.1.0 Introduced on the C-Series and E-Series. debug lldp interface — debugs LLDP. show lldp neighbors — displays the LLDP neighbors. advertise med voice To advertise a dedicated IP telephony handset or other appliances supporting interactive voice services, configure the system.
advertise med voice-signaling To advertise when voice control packets use a separate network policy than voice data, configure the system. Syntax advertise med voice-signaling {vlan-id layer2_priority DSCP_value} | {priority-tagged number} To return to the default, use the no advertise med voice-signaling {vlan-id layer2_priority DSCP_value} | {priority-tagged number} command. Parameters vlan-id Enter the VLAN ID. The range is from 1 to 4094.
30 Microsoft Network Load Balancing Network Load Balancing (NLB) is a clustering functionality that is implemented by Microsoft on Windows 2000 Server and Windows Server 2003 operating systems. Microsoft NLB clustering allows multiple servers running Microsoft Windows to be represented by one MAC and one IP address to provide transparent failover and load-balancing.
Related Commands clear arp-cache — clears dynamic ARP entries from the ARP table. show arp — displays the ARP table. mac-address-table static (for Multicast MAC Address) For multicast mode of network load balancing (NLB), configure a static multicast MAC address, associate the multicast MAC address with the VLAN used to switch Layer 2 multicast traffic, and add output ports that will receive multicast streams on the VLAN.
Example (Multicast) Version Description 9.3(0.0) Added support for multicast MAC address on the MXL platform. mac-address-table static 01:00:5E:01:00:01 {multicast vlan 2 output—range Te 1/1/2,Te 1/1/3} ip vlan-flooding Enable unicast data traffic flooding on VLAN member ports. Syntax ip vlan-flooding To disable, use the no ip vlan-flooding command. Command Modes Command History CONFIGURATION Version 9.3(0.
31 Multicast Source Discovery Protocol (MSDP) Multicast source discovery protocol (MSDP) connects multiple PIM Sparse-Mode (PIM-SM) domains together. MSDP peers connect using TCP port 639. Peers send keepalives every 60 seconds. A peer connection is reset after 75 seconds if no MSDP packets are received. MSDP connections are parallel with MBGP connections. The Dell Networking operating system supports MSDP commands on the S6000–ON platform.
clear ip msdp sa-cache Clears the entire source-active cache, the source-active entries of a particular multicast group, rejected, or local source-active entries. Syntax clear ip msdp sa-cache [group-address | rejected-sa | local] Parameters group-address Enter the group IP address in dotted decimal format (A.B.C.D.).
peer-address Enter the IP address of the MSDP peer. Defaults Without any options, this command clears the entire source-active cache. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.4.1.0 Introduced show ip msdp sa-cache rejected-sa — displays the rejected SAs in the SA cache. ip msdp default-peer Define a default peer from which to accept all source-active (SA) messages. Syntax ip msdp default-peer peer address [list name] To remove the default peer, use the no ip msdp default-peer {peer address} list name command.
ip msdp log-adjacency-changes Enable logging of MSDP adjacency changes. Syntax ip msdp log-adjacency-changes To disable logging, use the no ip msdp log-adjacency-changes command. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.1 Introduced An MSDP mesh group is a mechanism for reducing SA flooding, typically in an intra-domain setting. When some subset of a domain’s MSDP speakers are fully meshed, they can be configured into a mesh-group.
Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 6.2.1.1 Introduced ip msdp peer Configure an MSDP peer.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 7.5.1.0 Added option for SA upper limit and the description option. 6.2.1.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced Modifications to the ACL do not have an immediate effect on the sa-cache.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the E-Series. ip msdp sa-limit Configure the upper limit of source-active (SA) entries in SA-cache. Syntax ip msdp sa-limit number To return to the default, use the no ip msdp sa-limit number command. Parameters number Enter the maximum number of SA entries in SA-cache. The range is from 1 to 500000.
show ip msdp — displays the MSDP information. ip msdp shutdown Administratively shut down a configured MSDP peer. Syntax Parameters ip msdp shutdown {peer address} peer address Enter the peer address in a dotted decimal format (A.B.C.D.). Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.1 Introduced show ip msdp Display the MSDP peer status, SA cache, or peer summary.
Peer Addr: 100.1.1.1 Local Addr: 100.1.1.2(639) Connect Source: none State: Established Up/Down Time: 00:00:08 Timers: KeepAlive 60 sec, Hold time 75 sec SourceActive packet count (in/out): 0/0 SAs learned from this peer: 0 SA Filtering: Input (S,G) filter: none Output (S,G) filter: none Dell# Example (Sa-cache) Dell#show ip msdp sa-cache MSDP Source-Active Cache - 1 entries GroupAddr SourceAddr RPAddr 224.1.1.1 172.21.220.10 172.21.3.
UpTime 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 854 GroupAddr SourceAddr 225.1.2.1 10.1.1.3 225.1.2.2 10.1.1.4 225.1.2.3 10.1.1.3 225.1.2.4 10.1.1.4 225.1.2.5 10.1.1.3 225.1.2.6 10.1.1.4 225.1.2.7 10.1.1.3 225.1.2.8 10.1.1.4 225.1.2.9 10.1.1.3 225.1.2.10 10.1.1.4 225.1.2.11 10.1.1.3 225.1.2.11 10.1.1.3 225.1.2.12 10.1.1.4 225.1.2.13 10.1.1.3 225.1.2.14 10.1.1.4 225.1.
32 Multiple Spanning Tree Protocol (MSTP) Multiple spanning tree protocol (MSTP), as implemented by the Dell Networking operating system, conforms to IEEE 802.1s. This command supports the Dell Networking S6000–ON platform. debug spanning-tree mstp Enable debugging of the multiple spanning tree protocol and view information on the protocol.
Example Version Description 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series.
Related Commands protocol spanning-tree mstp — enters MULTIPLE SPANNING TREE mode. forward-delay The amount of time the interface waits in the Blocking State and the Learning State before transitioning to the Forwarding State. Syntax forward-delay seconds To return to the default setting, use the no forward-delay command. Parameters seconds Enter the number of seconds the interface waits in the Blocking State and the Learning State before transiting to the Forwarding State. The range is from 4 to 30.
hello-time Set the time interval between generation of MSTB bridge protocol data units (BPDUs). Syntax hello-time seconds To return to the default value, use the no hello-time command. Parameters seconds Enter a number as the time interval between transmission of BPDUs. The range is from 1 to 10. The default is 2 seconds. Defaults 2 seconds Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific.
Parameters max-age Enter a number of seconds the Dell Networking OS waits before refreshing configuration information. The range is from 6 to 40. The default is 20 seconds. Defaults 20 seconds Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Valid priority values are: 0, 4096, 8192, 12288, 16384, 20480, 24576, 28672, 32768, 36864, 40960, 45056, 49152, 53248, 57344, and 61440. All other values are rejected. Defaults default bridge-priority is 32768. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced. Usage Information For two MSTP switches to be within the same MSTP region, the switches must share the same region name (including matching case). Related Commands msti — maps the VLAN(s) to an MST instance.
Usage Information Version Description pre-6.2.1.1 Introduced on the E-Series. MSTP is not enabled when you enter MULTIPLE SPANNING TREE mode. To enable MSTP globally on the switch, enter the no disable command while in MULTIPLE SPANNING TREE mode. For more information about the multiple spanning tree protocol, refer to the Dell Networking OS Configuration Guide. Example Dell(conf)#protocol spanning-tree mstp Dell(config-mstp)#no disable Related Commands disable — disables multiple spanning tree.
Usage Information For two MSTP switches to be within the same MST region, the switches must share the same revision number. Related Commands msti — maps the VLAN(s) to an MST instance. name — assigns the region name to the MST region. show config View the current configuration for the mode. Only non-default values are shown. Syntax show config Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific.
show spanning-tree mst configuration View the multiple spanning tree configuration. Syntax show spanning-tree mst configuration Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
guard Command Modes Command History • EXEC • EXEC Privilege (Optional) Enter the keyword guard to display the type of guard enabled on an MSTP interface and the current port state. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Designated bridge has priority 16384, address 0001.e800.0a:5c Designated port id is 128.89, designated path cost Number of transitions to forwarding state 3 BPDU (Mrecords): sent 7, received 1103 The port is not in the portfast mode Example (EDS and LBK) The bold line shows the loopback BPDU inconsistency (LBK_INC). Dell#show spanning-tree msti 0 brief MSTI 0 VLANs mapped 1-4094 Executing IEEE compatible Spanning Tree Protocol Root ID Priority 32768, Address 0001.e801.
Example (Guard) Dell#show spanning-tree msti 5 guard Interface Name Instance Sts Guard type -------------------------------------Te 1/1/1 5 INCON(Root) Rootguard Te 1/2/1 5 FWD Loopguard Te 1/3/1 5 EDS(Shut) Bpduguard spanning-tree Enable the multiple spanning tree protocol on the interface. Syntax spanning-tree To disable the multiple spanning tree protocol on the interface, use the no spanning-tree command.
spanning-tree msti Configure multiple spanning tree instance cost and priority for an interface. Syntax spanning-tree msti instance {cost cost | priority priority} Parameters msti instance Enter the keyword msti and the MST instance number. The range is from zero (0) to 63. cost cost (OPTIONAL) Enter the keyword cost then the port cost value. The range is from 1 to 200000.
tc-flush-standard Enable the MAC address flushing after receiving every topology change notification. Syntax tc-flush-standard To disable, use the no tc-flush-standard command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
33 Multicast The multicast commands are supported by Dell Networking operating system (OS) on all S6000–ON platform. This chapter contains the following sections: • IPv4 Multicast Commands IPv4 Multicast Commands The following section contains the IPv4 multicast commands. clear ip mroute Clear learned multicast routes on the multicast forwarding table. To clear the protocol-independent multicast (PIM) tree information base, use the clear ip pim tib command.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series. E-Series legacy command Related Commands show ip pim tib — shows the PIM tree information base. ip mroute Assign a static mroute.
distance (OPTIONAL) Enter a number as the distance metric assigned to the mroute. The range is from 0 to 255. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(1.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series. 7.6.1.0 Introduced on the E-Series. This feature allows you to limit the number of multicast entries on the system. This number is the total of all the multicast entries on all line cards in the system. On each line card, the multicast module only installs the maximum number of entries, depending on the configured CAM profile. To store multicast routes, use the IN-L3-McastFib CAM partition.
show ip mroute View the multicast routing table. Syntax show ip mroute [vrf vrf-name] [static | group-address [source-address] | count | snooping [vlan vlan-idIntroduced on the S6000-ON.] [group-address [source-address]] | summary | vlt [group-address [source-address] | count] Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF.
Version Description 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Added support for keyword vlt to the Z9000, S4810, and S4820T. 8.4.1.1 Support for the keyword snooping and the optional vlan vlan-id, groupaddress, and source-address parameters were added on E-Series ExaScale. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Example (Static) Dell#show ip mroute static Mroute: 23.
Example Field Description (S, G) Displays the forwarding entry in the multicast route table. uptime Displays the amount of time the entry has been in the multicast forwarding table. Incoming interface Displays the reverse path forwarding (RPF) information towards the source for (S,G) entries and the RP for (*,G) entries.
Version Description 8.3.7.1 Introduced on the S4810. E-Series legacy command Usage Information Network administrators use static mroutes to control the reach-ability of the multicast sources. If a PIMregistered multicast source is reachable using static mroute as well as unicast route, the distance of each route is examined and the route with shorter distance is the one the PIM selects for reach-ability. NOTE: The default distance of mroutes is zero (0) and is CLI configurable on a per route basis.
34 Neighbor Discovery Protocol (NDP) The neighbor discovery protocol for IPv6 is defined in RFC 2461 as part of the Stateless Address Autoconfiguration protocol. It replaces the Address Resolution Protocol used with IPv4.
clear ipv6 neighbors Delete all entries in the IPv6 neighbor discovery cache or neighbors of a specific interface. Static entries are not removed using this command. Syntax Parameters clear ipv6 neighbors [ipv6-address | interface] ipv6-address Enter the IPv6 address of the neighbor in the x:x:x:x::x format to remove a specific IPv6 neighbor. NOTE: The :: notation specifies successive hexadecimal fields of zero.
count value • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Enter the keyword count then the number of debug outputs. The range is from 1 to 65534. The default is infinity. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
hop-limit Enable the verification of the advertised hop count limit. If this command is not configured, the verification process is bypassed. Syntax hop-limit {maximum | minimum limit} To reset the hop count limit, use the no hop-limit {maximum | minimum limit} command. Parameters maximum limit Enter the keyword maximum then the hop limit value. The range is from 0 to 254. minimum limit Enter the keyword minimum then the hop limit value. The range is from 0 to 254.
Related Commands Version Description 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. show ipv6 nd ra-guard policy — Displays the configuration applied on all the RA guard policies or a specific RA guard policy. ipv6 nd ra-guard enable Allow you to configure the RA guard related commands. Syntax ipv6 nd ra-guard enable To disable the RA guard, use the no ipv6 nd ra-guard enable command.
ipv6 neighbor Configure a static entry in the IPv6 neighbor discovery. Syntax ipv6 neighbor {ipv6-address} {interface interface} {hardware_address} To remove a static IPv6 entry from the IPv6 neighbor discovery, use the no ipv6 neighbor {ipv6address} {interface interface} command. Parameters ipv6-address Enter the IPv6 address of the neighbor in the x:x:x:x::x format. NOTE: The :: notation specifies successive hexadecimal fields of zero.
managed-config-flag Set the managed address configuration flag. Syntax managed-config-flag {on | off} To clear the flag, use the no managed-config-flag {on | off} command. Parameters on Enter the keyword on to set the managed-config-flag value as ON. off Enter the keyword off to set the managed-config flag value as OFF. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. • ipv6 nd raguard policy policy-name — Defines the RA guard policy name and enter the RA guard policy configuration mode.
To reset the MTU value, use the no mtu value command. Parameters value Enter the maximum transmission unit value in bytes. The range is from 1,280 to 11,982 bytes. Defaults 0 Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
reachable-time Enable the verification of the configured reachability time in the received RA packets. Syntax reachable—time value To reset the advertised reachability time, use the no reachable-timevalue command. Parameters value Enter the advertised reachability time in milliseconds. The range is from 0 to 3,600,000 milliseconds. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific.
Related Commands ipv6 nd raguard policy policy-name — Defines the router advertisement (RA) guard policy name and enter the RA guard policy configuration mode. router-lifetime Set the router lifetime. Syntax router—lifetime value Parameters value Enter the router lifetime in seconds. The range is from 0 to 9,000 seconds. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific.
Related Commands Version Description 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. • ipv6 nd ra-guard enable — Allow you to configure the RA guard related commands. • ipv6 nd raguard policy policy-name — Defines the router advertisement (RA) guard policy name and enter the RA guard policy configuration mode. show config Display the RA guard policy mode configurations.
show ipv6 nd ra-guard policy Display the configurations applied on all the RA guard policies or a specific RA guard policy. Syntax show ipv6 nd ra-guard policy policy-name Parameter policy policy-name Enter the keyword policy then the policy name. The policy name allows a maximum of 140 characters. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show ipv6 neighbors Display IPv6 discovery information. Entering the command without options shows all IPv6 neighbor addresses stored on the control processor (CP).
trusted-port Allow bypassing the configured RA guard validation and forwards the RA packets received on the interface, which has the trusted port policy attached. Syntax trusted-port To reset the policy applied to the trusted port, use the no trusted-port command. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
35 Object Tracking Object Tracking supports IPv4 and IPv6, and is available on the Dell Networking, C-Series, E-Series, S-Series, and S4810 platforms. Object tracking allows you to define objects of interest, monitor their state, and report to a client when a change in an object’s state occurs.
Example Version Description 8.4.1.0 Introduced. Dell#debug track all 04:35:04: %RPM0-P:RP2 %OTM-5-STATE: track 6 - Interface TenGigabitEthernet 1/2/1 line-protocol DOWN 04:35:04: %RPM0-P:RP2 %OTM-5-NOTIF: VRRP notification: resource ID 6 DOWN delay Configure the time delay used before communicating a change in the status of a tracked object to clients. Syntax delay {[up seconds] [down seconds]} To return to the default setting, use the no delay command.
description Enter a description of a tracked object. Syntax description {text} To remove the description, use the no description {text} command. Parameters text Enter a description to identify a tracked object (80 characters maximum). Defaults none Command Modes OBJECT TRACKING (conf_track_object-id) Command History Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced.
track 4 interface TenGigabitEthernet 1/2/1 ip routing track 5 ip route 192.168.0.0/24 reachability vrf red track resolution ip route isis 20 track resolution ip route ospf 10 Example (Object-id) Dell#show running-config track 300 track 300 ip route 10.0.0.0/8 metric threshold delay down 3 delay up 5 threshold metric up 100 Related Commands • show track – displays information about tracked objects, including configuration, current state, and clients which track the object.
Example Output Description Track object-id Displays the number of the tracked object. Interface type slot/ port, IP route ipaddress, IPv6 route ipv6-address Displays the interface type and slot/port number or address of the IPv4/IPv6 route that is being tracked. object is Up/Down Up/Down state of tracked object; for example, IPv4 interface, reachability or metric threshold of an IP route.
Related Commands • show running-config track – displays configuration information about tracked objects. • track interface ip routing – configures object tracking on the routing status of an IPv4 Layer 3 interface. • track interface line-protocol – configures object tracking on the line-protocol state of a Layer 2 interface. • track ip route metric threshold – configures object tracking on the threshold of an IPv4 route metric.
The tracking process uses a protocol-specific resolution value to convert the actual metric in the routing table to a scaled metric in the range 0 to 255. You can configure the resolution value used to scale route metrics for supported protocols with the track resolution ip route and track resolution ipv6 route commands. Related Commands • track ip route metric threshold – configures object tracking on the threshold of an IPv4 route metric.
track interface line-protocol Configure object tracking on the line-protocol state of a Layer 2 interface. Syntax track object-id interface interface line-protocol To return to the default setting, use the no track object-id command. Parameters object-id Enter the ID number of the tracked object. The range is 1 to 500.
ip-address/ prefixlen Enter an IPv4 address in dotted decimal format. The valid IPv4 prefix lengths are from /0 to /32. vrf vrf-name (Optional) E-Series only: You can configure a VPN routing and forwarding (VRF) instance to specify the virtual routing table to which the tracked route belongs. Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced.
Parameters object-id Enter the ID number of the tracked object. The range is 1 to 500. ip-address/ prefixlen Enter an IPv4 address in dotted decimal format. The valid IPv4 prefix lengths are from /0 to /32. vrf vrf-name (Optional) E-Series only: You can configure a VPN routing and forwarding (VRF) instance to specify the virtual routing table to which the tracked route belongs. Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.
Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. Use this command to configure the protocol-specific resolution value that converts the actual metric of an IPv4 route in the routing table to a scaled metric in the range 0 to 255.
show track ipv6 route Display information about all tracked IPv6 routes, including configuration, current tracked state (UP or DOWN), and the clients which are tracking an object. Syntax show track ipv6 route [brief] Parameters Command Modes Command History Usage Information Example brief • EXEC • EXEC Privilege (OPTIONAL) Display a single line summary of information for tracked IPv6 routes. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.
Usage Command Example (Brief) The following describes the show track ipv6 route brief command shown in the Example below. Ouput Description ResID Number of the tracked object. Resource Type of tracked object. Parameter Detailed description of the tracked object. State Up or Down state of the tracked object. Last Change Time since the last change in the state of the tracked object.
Usage Information Related Commands Version Description 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. Use this command to create an object that tracks the routing state of an IPv6 Layer 3 interface: • The status of the IPv6 interface is UP only if the Layer 2 status of the interface is UP and the interface has a valid IP address.
considers a lower value to have priority over a higher value. The resulting scaled value is compared against the configured threshold values to determine the state of a tracked route as follows: • If the scaled metric for a route entry is less than or equal to the UP threshold, the state of a route is UP. • If the scaled metric for a route is greater than or equal to the DOWN threshold or the route is not entered in the routing table, the state of a route is DOWN.
If the next-hop address in the ARP cache ages out for a route tracked for its reachability, an attempt is made to regenerate the ARP cache entry to if the next-hop address appears before considering the route DOWN. Related Commands • show track ipv6 route – displays information about tracked IPv6 routes, including configuration, current state, and clients which track the route. • track ipv6 route reachability – configures object tracking on the reachability of an IPv4 route.
Related Commands • threshold metric – configures the metric threshold used to determine the UP and/or DOWN state of a tracked route. • track ipv6 route metric threshold – configures object tracking on the threshold of an IPv6 route metric.
36 Open Shortest Path First (OSPFv2 and OSPFv3) Open Shortest Path First version 2 for IPv4 is supported on platform. OSPF is an Interior Gateway Protocol (IGP), which means that it distributes routing information between routers in a single Autonomous System (AS). OSPF is also a link-state protocol in which all routers contain forwarding tables derived from information about their links to their neighbors.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. area range Summarize routes matching an address/mask at an area border router (ABR).
Version Description pre- 6.1.1.1 Introduced on the E-Series. Usage Information Only the routes within an area are summarized, and that summary is advertised to other areas by the ABR. External routes are not summarized. Related Commands area stub — creates a stub area. router ospf — enters ROUTER OSPF mode to configure an OSPF instance. area stub Configure a stub area, which is an area not connected to other areas.
auto-cost Specify how the OSPF interface cost is calculated based on the reference bandwidth method. S6000–ON Syntax auto-cost [reference-bandwidth ref-bw] To return to the default bandwidth or to assign cost based on the interface type, use the no auto-cost [reference-bandwidth] command. Parameters ref-bw (OPTIONAL) Specify a reference bandwidth in megabits per second. The range is from 1 to 4294967. The default is 100 megabits per second. Defaults 100 megabits per second.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.
Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Added the database-timer rate-limit option for the S4810. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series.
Example Field Description dst: Displays the destination IP address. netmask: Displays the destination IP address mask.
• route-map mapname 2 = Type 2 external route (OPTIONAL) Enter the keywords route-map then the name of an established route map. Defaults Disabled. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. description Add a description about the selected OSPF configuration. S6000–ON Syntax description description To remove the OSPF description, use the no description command.
distance Define an administrative distance for particular routes to a specific IP address. S6000–ON Syntax distance weight [ip-address mask access-list-name] To delete the settings, use the no distance weight [ip-address mask access-list-name] command. Parameters weight Specify an administrative distance. The range is from 1 to 255. The default is 110. ip-address (OPTIONAL) Enter a router ID in the dotted decimal format. If you enter a router ID, include the mask for that router address.
Parameters Defaults external dist3 (OPTIONAL) Enter the keyword external then a number to specify a distance for external type 5 and 7 routes. The range is from 1 to 255. The default is 110. inter-area dist2 (OPTIONAL) Enter the keywords inter-area then a number to specify a distance metric for routes between areas. The range is from 1 to 255. The default is 110. intra-area dist1 (OPTIONAL) Enter the keywords intra-area then a number to specify a distance metric for all routes within an area.
• For Port Channel groups, enter the keywords port-channel then a number. For the C-Series, S-Series, and Z9000, the range is from 1 to 128.For Z9500, the range is from 1 to 512. • For a SONET interface, enter the keyword sonet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
connected (OPTIONAL) Enter the keyword connected to specify that connected routes are distributed. isis (OPTIONAL) Enter the keyword isis to specify that IS-IS routes are distributed. NOTE: BGP and ISIS routes are not available on the C-Series. BGP, ISIS, and RIP routes are not available on the S-Series. rip (OPTIONAL) Enter the keyword rip to specify that RIP routes are distributed. NOTE: BGP and ISIS routes are not available on the C-Series.
Parameters number Enter the convergence level desired. The higher this parameter is set, the faster OSPF converge takes place. The range is from 1 to 4. Defaults none. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series and E-Series. In OSPF, flooding is the most resource-consuming task. The flooding algorithm, described in RFC-2328, requires that OSPF flood LSAs (Link State Advertisements) on all interfaces, as governed by LSA’s flooding scope (see Section 13 of the RFC).
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. Added support for Multi-Process OSPF. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. The Helper mode is enabled by default on the device. To enable the restart mode also on the device, you must configure the grace period using this command. After you enable restart mode the router advertises the neighbor as fully adjacent during a restart.
graceful-restart mode Enable the graceful restart mode. S6000–ON Syntax graceful-restart mode [planned-only | unplanned-only] To disable graceful restart mode, use the no graceful-restart mode command. Parameters planned-only (OPTIONAL) Enter the keywords planned-only to indicate graceful restart is supported in a planned restart condition only. unplanned-only (OPTIONAL) Enter the keywords unplanned-only to indicate graceful restart is supported in an unplanned restart condition only.
Defaults By default, OSPF routers are both helper and restart routers during a graceful restart. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T.
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. ip ospf authentication-key Enable authentication and set an authentication key on OSPF traffic on an interface. S6000–ON Syntax ip ospf authentication-key [encryption-type] key To delete an authentication key, use the no ip ospf authentication-key command. Parameters encryption-type (OPTIONAL) Enter 7 to encrypt the key.
To return to default value, use the no ip ospf cost command. Parameters cost Enter a number as the cost. The range is from 1 to 65535. Defaults The default cost is based on the reference bandwidth. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. Usage Information By default, the dead interval is four times the default hello-interval.
Usage Information The time interval between the hello packets must be the same for routers in a network. Related Commands ip ospf dead-interval — sets the time interval before a router is declared dead. ip ospf message-digest-key Enable OSPF MD5 authentication and send an OSPF message digest key on the interface. S6000–ON Syntax ip ospf message-digest-key keyid md5 key To delete a key, use the no ip ospf message-digest-key keyid command. Parameters keyid Enter a number as the key ID.
NOTE: The MD5 secret is stored as plain text in the configuration file with service password encryption. Write down or otherwise record the key. You cannot learn the key once it is configured. Use caution when changing the key. ip ospf mtu-ignore Disable OSPF MTU mismatch detection upon receipt of database description (DBD) packets. S6000–ON Syntax ip ospf mtu-ignore To return to the default, use the no ip ospf mtu-ignore command. Defaults Enabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.
Usage Information Version Description pre- 6.1.1.1 Introduced on the E-Series. Setting a priority of 0 makes the router ineligible for election as a designated router or backup designated router. Use this command for interfaces connected to multi-access networks, not point-to-point networks. ip ospf retransmit-interval Set the retransmission time between lost link state advertisements (LSAs) for adjacencies belonging to the interface.
ip ospf transmit-delay To send a link state update packet on the interface, set the estimated time elapsed. S6000–ON Syntax ip ospf transmit-delay seconds To return to the default value, use the no ip ospf transmit-delay command. Parameters seconds Enter the number of seconds as the interval between retransmission. The range is from 1 to 3600. The default is 1 second. This value must be greater than the transmission and propagation delays for the interface.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. mib-binding Enable this OSPF process ID to manage the SNMP traps and process SNMP queries. S6000–ON Syntax mib-binding To mib-binding on this OSPF process, use the no mib-binding command. Defaults none. Command Modes ROUTER OSPF Command History This guide is platform-specific.
mask Enter a network mask in /prefix format. (/x) area-id Enter the OSPF area ID as either a decimal value or in a valid IP address. Decimal value range is from 0 to 65535. IP address format is dotted decimal format A.B.C.D. NOTE: If the area ID is smaller than 65535, it is converted to a decimal value. For example, if you use an area ID of 0.0.0.1, it is converted to 1. Command Modes ROUTER OSPF Command History This guide is platform-specific.
interface Enter the following keywords and slot/port or number information: • For a Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For Port Channel groups, enter the keywords port-channel then a number. For the C-Series, S-Series, and Z9000, the range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
• All present and future OSPF interfaces are marked as passive. • Any adjacency is explicitly terminated from all OSPF interfaces. • All previous passive-interface interface commands are removed from the running configuration. • All previous no passive-interface interface commands are removed from the running configuration. no passive-interface interface • Remove the interface from the passive list. • The ABR status for the router is updated.
route-map mapname (OPTIONAL) Enter the keywords route-map then the name of the route map. tag tag-value (OPTIONAL) Enter the keyword tag then a number. The range is from 0 to 4294967295. Defaults Not configured. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
metric-type typevalue (OPTIONAL) Enter the keywords metric-type then one of the following: • 1 = for OSPF External type 1 • 2 = for OSPF External type 2 route-map mapname (OPTIONAL) Enter the keywords route-map then the name of the route map. tag tag-value (OPTIONAL) Enter the keyword tag to set the tag for routes redistributed into OSPF. The range is from 0 to 4294967295. Defaults none Command Modes ROUTER OSPF Command History This guide is platform-specific.
level-1-2 (OPTIONAL) Enter the keywords level-1-2 to redistribute both IS-IS Level-1 and Level-2 routes. level-2 (OPTIONAL) Enter the keywords level-2 to redistribute only IS-IS Level-2 routes. metric metric-value (OPTIONAL) Enter the keyword metric then a number. The range is from 0 (zero) to 4294967295.
Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Added support for OSPFv3 on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Example Dell(conf-router_ospf)#show config ! router ospf 3 passive-interface 0 TenGigabitEthernet 1/1/1 Dell(conf-router_ospf)# show ip ospf Display information on the OSPF process configured on the switch. S6000–ON Syntax show ip ospf [process-id] Parameters Command Modes Command History process-id • EXEC • EXEC Privilege Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. This guide is platform-specific.
Line Beginning with Description “Supports only...” Displays the number of Type of Service (TOS) rouse supported. “SPF schedule...” Displays the delay and hold time configured for this process ID. “Convergence Level” “Min LSA....” Displays the intervals set for LSA transmission and acceptance. “Number of...” Displays the number and type of areas configured for this process ID. Example Dell#show ip ospf 10 Routing Process ospf 10 with ID 1.1.1.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support of Multi-Process OSPF. 7.8.1.0 Added the process-id option, in support of Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series and E-Series. To isolate problems with external routes, use this command.
Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support of Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. The following describes the show ip ospf process-id database command shown in the following example.
172.16.1.0 Dell> Related Commands 13.1.1.1 148 0x8000006d 0x533b 0 show ip ospf database asbr-summary — displays only ASBR summary LSA information. show ip ospf database asbr-summary Display information about autonomous system (AS) boundary LSAs. S6000–ON Syntax show ip ospf [process-id | vrf vrf-name] database asbr-summary [link-stateid] [adv-router ip-address] Parameters process-id Enter the OSPF Process ID to show a specific process.
Example Field Description LS Age Displays the LSA’s age. Options Displays the optional capabilities available on router. The following options can be found in this item: • TOS-capability or No TOS-capability is displayed depending on whether the router can support Type of Service. • DC or No DC is displayed depending on whether the originating router can support OSPF over demand circuits. • E or No E is displayed on whether the originating router can accept AS External LSAs.
show ip ospf database external Display information on the AS external (type 5) LSAs. Syntax show ip ospf [process-id] database external [link-state-id] [adv-router ipaddress] Parameters process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. link-state-id (OPTIONAL) Specify LSA ID in dotted decimal format.
Field Example Description • TOS-capability or No TOS-capability is displayed depending on whether the router can support Type of Service. • DC or No DC is displayed depending on whether the originating router can support OSPF over demand circuits. • E or No E is displayed on whether the originating router can accept AS External LSAs. LS Type Displays the LSA’s type. Link State ID Displays the Link State ID. Advertising Router Identifies the router ID of the LSA’s originating router.
Metrics Type: 2 TOS: 0 Metrics: 1 Forward Address: 0.0.0.0 External Route Tag: 701 Dell# Related Commands show ip ospf database — displays OSPF database information. show ip ospf database network Display the network (type 2) LSA information. Syntax show ip ospf [process-id] database network [link-state-id] [adv-router ipaddress] Parameters process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Usage Information Example The following describes the show ip ospf process-id database network command shown in the following example. Field Description LS Age Displays the LSA’s age. Options Displays the optional capabilities available on router. The following options can be found in this item: • TOS-capability or No TOS-capability is displayed depending on whether the router can support Type of Service.
Related Commands show ip ospf database — displays OSPF database information. show ip ospf database nssa-external Display NSSA-External (type 7) LSA information. Syntax show ip ospf [process-id] database nssa-external [link-state-id] [advrouter ip-address] Parameters process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. link-state-id (OPTIONAL) Specify LSA ID in dotted decimal format.
show ip ospf database opaque-area Display the opaque-area (type 10) LSA information. Syntax Parameters show ip ospf [process-id] database opaque-area [link-state-id] [adv-router ip-address] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. link-state-id (OPTIONAL) Specify LSA ID in dotted decimal format.
Item Example Description • TOS-capability or No TOS-capability is displayed depending on whether the router can support Type of Service. • DC or No DC is displayed depending on whether the originating router can support OSPF over demand circuits. • E or No E is displayed on whether the originating router can accept AS External LSAs. LS Type Displays the LSA’s type. Link State ID Displays the Link State ID. Advertising Router Identifies the advertising router’s ID.
link-state-id adv-router ipaddress Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Specify LSA ID in dotted decimal format. The LSA ID value depends on the LSA type, and it can be one of the following: • the network’s IP address for Type 3 LSAs or Type 5 LSAs • the router’s OSPF router ID for Type 1 LSAs or Type 4 LSAs • the default destination (0.0.0.
• adv-router ipaddress Command Modes Command History • EXEC • EXEC Privilege the default destination (0.0.0.0) for Type 5 LSAs (OPTIONAL) Enter the keywords adv-router then the IP address of an Advertising Router to display only the LSA information about that router. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.20 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Example Item Description (Link ID) Identifies the link type and address. (Link Data) Identifies the router interface address. Number of TOS Metric Lists the number of TOS metrics. TOS 0 Metric Lists the number of TOS 0 metrics. Dell#show ip ospf 100 database router OSPF Router with ID (1.1.1.10) (Process ID 100) Router (Area 0) LS age: 967 Options: (No TOS-capability, No DC, E) LS type: Router Link State ID: 1.1.1.10 Advertising Router: 1.1.1.
show ip ospf database summary Display the network summary (type 3) LSA routing information. Syntax Parameters show ip ospf [process-id] database summary [link-state-id] [adv-router ipaddress] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. link-state-id (OPTIONAL) Specify LSA ID in dotted decimal format.
Item Example Description • TOS-capability or No TOS-capability is displayed depending on whether the router can support Type of Service. • DC or No DC is displayed depending on whether the originating router can support OSPF over demand circuits. • E or No E is displayed on whether the originating router can accept AS External LSAs. LS Type Displays the LSA type. Link State ID Displays the Link State ID. Advertising Router Identifies the router ID of the LSA’s originating router.
Dell# Related Commands show ip ospf database — displays OSPF database information. show ip ospf interface Display the OSPF interfaces configured. If OSPF is not enabled on the switch, no output is generated. Syntax Parameters Command Modes Command History show ip ospf [process-id | vrf vrf-name] interface [interface] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Usage Information Example Version Description 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series. The following describes the show ip ospf process-id interface command shown in the following example. Item Description GigabitEthernet... This line identifies the interface type slot/port and the status of the OSPF protocol on that interface. Internet Address... This line displays the IP address, network mask and area assigned to this interface. Process ID...
Loopback interface is treated as a stub Host. Dell> show ip ospf neighbor Display the OSPF neighbors connected to the local router. Syntax Parameters show ip ospf [process-id] neighbor process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. Command Modes EXEC Privilege Command History This guide is platform-specific.
192.10.10.2 1 FULL/DR 00:00:37 192.10.10.2 Te 1/2/1 0.0.0.1 20.20.20.1 1 FULL/DROTHER00:00:36 192.10.10.4 Te 1/3/1 0.0.0.1 Dell# show ip ospf routes Display routes OSPF calculates and stores in OSPF RIB. Syntax show ip ospf [process-id] routes Parameters Defaults process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
NOTE: Starting with Version 9.4(0.0), the loopback IP address advertised to the neighbor is not displayed in the output because they are not accounted as inactive OSPF routes, whereas the loopback IP address is displayed until Dell Networking OS Version 9.3(0.0). Starting with Version 9.4(0.0), the show ip ospf routes command displays the interface and area ID information of connected networks in addition to the other settings, whereas these details are not displayed until Dell Networking OS Version 9.3(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000.
Example Error Type Description Intf_Down Received packets on an interface that is either down or OSPF is not enabled. Non-Dr Received packets with a destination address of ALL_DRS even though SELF is not a designated router. Self-Org Receive the self originated packet. Wrong_Len The received packet length is different to what was indicated in the OSPF header. Invld-Nbr LSA, LSR, LSU, and DDB are received from a peer which is not a neighbor peer.
Example (Statistics) • The hello-timer remaining value for each interface • The wait-timer remaining value for each interface • The grace-timer remaining value for each interface • The packet count received and transmitted for each neighbor • Dead timer remaining value for each neighbor • Transmit timer remaining value for each neighbor • The LSU Q length and its highest mark for each neighbor • The LSR Q length and its highest mark for each neighbor Dell(conf-if-te-1/6/1)#do show ip ospf s
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810. Dell#show ip ospf 10 timers rate-limit List of LSAs in rate limit Queue LSA id: 1.1.1.0 Type: 3 Adv Rtid: 3.3.3.3 Expiry time: 00:00:09.111 LSA id: 3.3.3.3 Type: 1 Adv Rtid: 3.3.3.3 Expiry time: 00:00:23.96 Dell# show ip ospf topology Display routers in directly connected areas.
Usage Information To isolate problems with inter-area and external routes, use this command. In OSPF inter-area and external routes are calculated by adding LSA cost to the cost of reaching the router. If an inter-area or external route is not of correct cost, the display can determine if the path to the originating router is correct or not. Example Dell#show ip ospf 1 topology Router ID 3.3.3.3 1.1.1.1 Dell# Flags Cost E/B/-/ 1 E/-/-/ 1 Nexthop 20.0.0.3 10.0.0.
With the not-advertise parameter configured, you can use this command to filter out some external routes. For example, if you want to redistribute static routes to OSPF, but you don't want OSPF to advertise routes with prefix 1.1.0.0, you can configure the summary-address 1.1.0.0 255.255.0.0 not-advertise to filter out all the routes fall in range 1.1.0.0/16. Related Commands area range — summarizes routes within an area.
Dell(conf)#router ospf 1 Dell(conf-router_ospf-1)#timer spf 2 5 Dell(conf-router_ospf-1)# Dell(conf-router_ospf-1)#show config ! router ospf 1 timers spf 2 5 Dell(conf-router_ospf-1)# Dell(conf-router_ospf-1)#end Dell# Dell# timers throttle lsa all Configure LSA transmit intervals. Syntax timers throttle lsa all {start-interval | hold-interval | max-interval} To return to the default, use the no timers throttle lsa command.
100,000, the LSA is sent at 5000 msec, then 1000 msec, then 2000 msec, them 4000 until 100,000 msec is reached. timers throttle lsa arrival Configure the LSA acceptance intervals. Syntax timers throttle lsa arrival arrival-time To return to the default, use the no timers throttle lsa command. Parameters arrival-time Set the interval between receiving the same LSA repeatedly, to allow sufficient time for the system to accept the LSA. The range is from 0 to 600,000 milliseconds.
Parameters area area-id Area for which OSPFv3 traffic is to be authenticated. For area-id, you can enter a number. The range is from 0 to 4294967295. ipsec spi number Security Policy index (SPI) value that identifies an IPsec security policy. The range is from 256 to 4294967295. MD5 | SHA1 Authentication type: Message Digest 5 (MD5) or Secure Hash Algorithm 1 (SHA-1). key-encryptiontype (OPTIONAL) Specifies if the key is encrypted. The values are 0 (key is not encrypted) or 7 (key is encrypted).
Related Commands ipv6 ospf authentication – configures an IPsec authentication policy on an OSPFv3 interface. show crypto ipsec policy – displays the configuration of IPsec authentication policies. area encryption Configure an IPsec encryption policy for OSPFv3 packets in an OSPFv3 area.
For SHA-1 authentication, the key must be 40 hex digits (non-encrypted) or 80 hex digits (encrypted). null Causes an encryption policy configured for the area to not be inherited on the interface. Defaults Not configured. Command Modes ROUTER OSPFv3 Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Parameters Command Modes Command History vrf vrf-name • EXEC • EXEC Privilege (Optional) Enter the keyword vrf followed by the name of the VRF to clear IPv6 routes corresponding to that VRF. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. 9.2(1.
Usage Information Example Version Description 9.2.(0.0) Introduced on the S4820T, S4810, and Z9000. The following section describes the command fields. Lines Beginning With or Including Description OSPFv3... Debugging is on for all OSPFv3 packets and all interfaces. 05:21:01 Displays the time stamp. Sending Ver:3 Sending OSPF3 version..
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Lines Beginning With or Including Description Length: Displays the packet length. Router ID: Displays the OSPF3 router ID. Area ID: Displays the Area ID. Chksum: Displays the OSPF3 checksum. default-information originate Configure the Dell Networking OS to generate a default external route into an OSPFv3 routing domain.
graceful-restart grace-period Enable OSPFv3 graceful restart globally by setting the grace period (in seconds) that an OSPFv3 router’s neighbors continues to advertise the router as adjacent during a graceful restart. Syntax graceful-restart grace-period seconds To disable OSPFv3 graceful restart, enter no graceful-restart grace-period. Parameters seconds Time duration, in seconds, that specifies the duration of the restart process before OSPFv3 terminates the process.
unplanned-only (OPTIONAL) Enter the keywords unplanned-only to indicate graceful restart is supported in an unplanned restart condition only. Defaults OSPFv3 graceful restart supports both planned and unplanned failures. Command Modes ROUTER OSPFv3 Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 7.4.1.0 Introduced on the E-Series and C-Series. ipv6 ospf authentication Configure an IPsec authentication policy for OSPFv3 packets on an IPv6 interface. Syntax Parameters ipv6 ospf authentication {null | ipsec spi number {MD5 | SHA1} [keyencryption-type] key}} null Causes an authentication policy configured for the area to not be inherited on the interface. ipsec spi number Security Policy index (SPI) value that identifies an IPsec security policy.
To remove an IPsec authentication policy from an interface, enter the no ipv6 ospf authentication spi number command. To remove null authentication on an interface to allow the interface to inherit the authentication policy configured for the OSPFv3 area, enter the no ipv6 ospf authentication null command. Related Commands area authentication – configures an IPsec authentication policy for an OSPFv3 area. show crypto ipsec policy – displays the configuration of IPsec authentication policies.
ipv6 ospf dead-interval Set the time interval since the last hello-packet was received from a router. After the time interval elapses, the neighboring routers declare the router down. Syntax ipv6 ospf dead-interval seconds To return to the default time interval, use the no ipv6 ospf dead-interval command. Parameters seconds Enter the time interval in seconds. The range is from 1 to 65535 seconds. Defaults 40 seconds (Ethernet).
For AES-CBC, only the AES-128 and AES-192 ciphers are supported. key-encryptiontype (OPTIONAL) Specifies if the key is encrypted. Valid values: 0 (key is not encrypted) or 7 (key is encrypted). key Text string used in authentication. The required lengths of a non-encrypted or encrypted key are: 3DES - 48 or 96 hex digits; DES - 16 or 32 hex digits; AES-CBC -32 or 64 hex digits for AES-128 and 48 or 96 hex digits for AES-192.
authentication policy configured for the OSPFv3 area, enter the no ipv6 ospf no ipv6 ospf encryption null command. Related Commands area encryption – configures an IPsec encryption policy for an OSPFv3 area. show crypto ipsec policy – displays the configuration of IPsec encryption policies. show crypto ipsec sa ipv6 – displays the security associations set up for OSPFv3 interfaces in encryption policies.
Parameters seconds Enter the time interval in seconds as the time between hello packets. The range is from 1 to 65525 seconds. Defaults 10 seconds (Ethernet). Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.1.(0.0) Introduced on the S4810 and Z9000.
Use this command for interfaces connected to multi-access networks, not point-to-point networks. ipv6 router ospf Enable OSPF for IPv6 router configuration. Syntax ipv6 router ospf process-id [vrf vrf-name] To exit OSPF for IPv6, use the no ipv6 router ospf process-id command. Parameters process-id Enter the process identification number. The range is from 1 to 65535. vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to install IPv6 routes in that VRF.
Command History Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.1 Introduced on the E-Series.
traffic destined to other networks through the new router for a specified time until the router’s switching and routing functions are up and running, and the routing tables in network routers have converged. By using the max-metric router-lsa command, you force the link cost of all OSPF non-stub links to the maximum link cost (65535). The advertisement of this maximum metric causes other routers to assign a cost to the new router that is higher than the cost of using an alternate path.
passive-interface Disable (suppress) sending routing updates on an interface. Syntax passive—interface interface To enable sending routing updates on an interface, use the no passive-interface interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
redistribute Redistribute into OSPFv3. Syntax redistribute {bgp as number}{connected | static}[metric metric-value | metric-type type-value] [route-map map-name] [tag tag-value] To disable redistribution, use the no redistribute {connected | static} command. Parameters bgp as number Enter the keyword bgp then the autonomous system number. The range is from 1 to 65535. connected Enter the keyword connected to redistribute routes from physically connected interfaces.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.1.(0.0) Introduced support for OSPFv3 on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for the C-Series. 7.4.1.0 Introduced on the E-Series.
If this command is used on an OSPFv3 process that is already active (has neighbors), all the neighbor adjacencies are brought down immediately and new sessions are initiated with the new router ID. Related Commands clear ipv6 ospf process – resets an OSPFv3 router process. show crypto ipsec policy Display the configuration of IPsec authentication and encryption policies. Syntax Parameters show crypto ipsec policy [name name] name name (OPTIONAL) Displays configuration details about a specified policy.
Crypto IPSec client security policy data Policy name : OSPFv3-0-501 Policy refcount : 1 Inbound ESP SPI : 501 (0x1F5) Outbound ESP SPI : 501 (0x1F5) Inbound ESP Auth Key : bbdd96e6eb4828e2e27bc3f9ff541e43faa759c9ef5706ba8ed8bb5efe91e97eb7c0 c30808825fb5 Outbound ESP Auth Key : bbdd96e6eb4828e2e27bc3f9ff541e43faa759c9ef5706ba8ed8bb5efe91e97eb7c0 c30808825fb5 Inbound ESP Cipher Key : bbdd96e6eb4828e2e27bc3f9ff541e43faa759c9ef5706ba10345a1039ba8f8a Outbound ESP Cipher Key : bbdd96e6eb4828e2e27bc3f9ff541e43faa7
Parameters interface interface (OPTIONAL) Displays information about the SAs used on a specified OSPFv3 interface, where interface is one of the following values: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
outbound esp sas Interface: TenGigabitEthernet 1/2/1 Link Local address: fe80::201:e8ff:fe40:4d11 IPSecv6 policy name: OSPFv3-1-600 inbound ah sas outbound ah sas inbound esp sas spi : 600 (0x258) transform : esp-des esp-sha1-hmac in use settings : {Transport, } replay detection support : N STATUS : ACTIVE outbound esp sas spi : 600 (0x258) transform : esp-des esp-sha1-hmac in use settings : {Transport, } replay detection support : N STATUS : ACTIVE show crypto ipsec sa ipv6 Command Fields Field Descripti
Parameters process-number Enter the OSPF process number. vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to display neighbors corresponding to that VRF. NOTE: If you do not specify this option, neighbors corresponding to the default VRF are displayed. database-summary (OPTIONAL) Enter the keywords database-summary to view a summary of database LSA information.
Process 1 database summary Type Count/Status Oper Status 1 Admin Status 1 Area Bdr Rtr Status 1 AS Bdr Rtr Status 1 AS Scope LSA Count 0 AS Scope LSA Cksum sum 0 Originate New LSAS 50 Rx New LSAS 22 Ext LSA Count 0 Rte Max Eq Cost Paths 10 GR grace-period 180 GR mode planned and unplanned Area 0 database summary Type Count/Status Brd Rtr Count 1 AS Bdr Rtr Count 1 LSA count 6 Rtr LSA Count 2 Net LSA Count 1 Inter Area Pfx LSA Count 1 Inter Area Rtr LSA Count 0 Group Mem LSA Count 0 Type-7 LSA count 0 Intra
interface Defaults none Command Modes EXEC Command History Usage Information (OPTIONAL) Enter one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display OSPF neighbors corresponding to that VRF. NOTE: If you do not specify this option, neighbors corresponding to the default VRF are displayed. interface Defaults none Command Modes EXEC (OPTIONAL) Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
holdtime Defaults Enter a number as the hold time. The range is from 0 to 4294967295. The default is 10 seconds. • delay = 5 seconds • holdtime = 10 seconds Command Modes ROUTER OSPFv3 for OSPFv3 Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.
37 Policy-based Routing (PBR) Policy-based routing (PBR) allows you to apply routing policies to specific interfaces. To enable PBR, create a redirect list and apply it to the interface. After the redirect list is applied to the interface, all traffic passing through the interface is subject to the rules defined in the redirect list. PBR is supported by the Dell Networking Operating System (OS).
ip redirect-group Apply a redirect list (policy-based routing) on an interface. You can apply multiple redirect lists to an interface by entering this command multiple times. Syntax ip redirect-group redirect-list-name To remove a redirect list from an interface, use the no ip redirect-group name command. Parameters redirect-list-name Enter the name of a configured redirect list. Defaults none Command Modes INTERFACE (conf-if-vl-) Command History Usage Information Version Description 9.7(0.
Parameters redirect-list-name Defaults None Command Modes CONFIGURATION Command History Enter the name of a redirect list. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.2.0 Introduced on the E-Series Tera Scale. 7.7.1.0 Introduced on the E-Series ExaScale. permit Configure a permit rule.
operator Defaults none Command Modes REDIRECT-LIST Command History • ack = acknowledgement • fin = finish (no more data from the user) • psh = push function • rst = reset the connection • syn = synchronize sequence number • urg = urgent field (OPTIONAL) For TCP and UDP parameters only.
ip-address Enter the IP address of the forwarding router. slot/port Enter the keyword slot / port followed by the slot/port information. tunnel Enter the keyword tunnel to configure the tunnel setting. tunnel-id Enter the keyword tunnel-id to redirect the traffic. track Enter the keyword track to enable the tracking. track Enter the keyword track to track object-id. ip-protocol-number Enter a number from 0 to 255 for the protocol identified in the IP protocol header.
Version Description 9.7(0.0) Added support for the track-id on the S4810, S4820T, S6000, and Z9000. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.2.0 Introduced on the E-Series Tera Scale. 7.7.1.0 Introduced on the E-Series ExaScale. seq Configure a filter with an assigned sequence number for the redirect list.
host ip-address Enter the keyword host then the IP address to specify a host IP address. destination Enter the IP address of the network or host to which the packets are sent. bit (OPTIONAL) For the TCP protocol type only, enter one or a combination of the following TCP flags: operator • fin = finish (no more data from the user) • psh = push function • rst = reset the connection • syn = synchronize sequence number • urg = urgent field (OPTIONAL) For the TCP and UDP parameters only.
show cam pbr Display the PBR CAM content. Syntax Parameters show cam pbr {[interface interface] | stack—unit slot-number port-set number]} [summ interface interface Enter the keyword interface then the name of the interface. stack–unit number Enter the keyword stack-unit then the slot number. port-set number Enter the keywords port-set then the port-pipe number. summary Enter the keyword summary to view only the total number of CAM entries.
Parameters Command Modes Command History Example 1018 redirect-list-name • EXEC • EXEC Privilege Enter the name of a configured Redirect list. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. Dell#show ip redirect-list explicit_tunnel IP redirect-list explicit_tunnel: Defined as: seq 5 redirect tunnel 1 track 1 tcp 155.55.2.0/24 222.22.2.
38 PIM-Sparse Mode (PIM-SM) The protocol-independent multicast (PIM) commands are supported by the Dell Networking operating software on the platform. IPv4 PIM-Sparse Mode Commands The following describes the IPv4 PIM-sparse mode (PIM-SM) commands. clear ip pim rp-mapping The bootstrap router (BSR) feature uses this command to remove all or particular rendezvous point (RP) advertisement.
Usage Information This command re-applies the RP mapping logic for all the groups learnt by the node. Any stale information corresponding to the existing mapping configuration is updated. As a result, the existing BSR cache and the *,G's are deleted only if these entries are stale. clear ip pim tib Clear PIM tree information from the PIM database.
debug ip pim View IP PIM debugging messages. Syntax debug ip pim [vrf vrf-name] [bsr | events | group | packet [in | out] | register | state | timer [assert | hello | joinprune | register]] To disable PIM debugging, use the no debug ip pim [vrf vrf-name] command or use the undebug allto disable all debugging command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to view IP PIM debugging messages corresponding to that VRF.
Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. ip pim bsr-border Define the border of PIM domain by filtering inbound and outbound PIM-BSR messages per interface. Syntax ip pim bsr-border To return to the default value, use the no ip pim bsr-border command.
Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure the PIM router on a VRF. interface Enter the following keywords and slot/port or number information: • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
Defaults 1 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series for the port-channels and the S-Series. 7.7.1.0 Introduced on the E-Series. Example Dell(conf)# ip access-list extended iptv-channels Dell(config-ext-nacl)# permit ip 10.1.2.3/24 225.1.1.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series and S-Series. 7.6.1.0 Introduced on the E-Series. Do not enter this command before creating the access-list. ip pim query-interval Change the frequency of PIM Router-Query messages. Syntax ip pim query-interval seconds To return to the default value, use the no ip pim query-interval seconds command.
To return to the default, use the no ip pim [vrf vrf-name] register-filter access-list command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. access-list Enter the name of an extended access list. Maximum 16 characters. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
group-address group-address mask Enter the keywords group-address then a group-address mask, in dotted decimal format (/xx), to assign that group address to the RP. override Enter the keyword override to override the BSR updates with static RP. The override takes effect immediately during enable/disable. NOTE: This option is applicable to multicast group range. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
priority • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a VLAN, enter the keyword vlan then a number from 1 to 4094. (OPTIONAL) Enter the priority used in Bootstrap election process. The range is zero (0) to 255.
Usage Information Version Description 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series for the port-channels and the S-Series. The interface must be enabled (the no shutdown command) and not have the switchport command configured.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series for the port-channels and the S-Series. 7.7.1.1 Introduced This command configures an expiration timer for all S.G entries, unless they are assigned to an Extended ACL.
Usage Information Dell Networking OS supports standard access lists for the SSM range. You cannot use extended ACLs for configuring the SSM range. If you configure an extended ACL and then used in the ip pim ssm-range {access list name} configuration, an error is reported. However, if you configure ip pim ssm-range {access list name} first and then you configure the ACL as an Extended ACL, an error is not reported and the ACL is not applied to the SSM range.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. This command is applicable to last hop routers on the shared tree towards the rendezvous point (RP). show ip pim bsr-router View information on the Bootstrap router. S6000–ON Syntax Command Modes Command History show ip pim [vrf vrf-name] bsr-router • EXEC • EXEC Privilege This guide is platform-specific.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
show ip pim neighbor View PIM neighbors. S6000–ON Syntax Command Modes Command History show ip pim [vrf vrf-name] neighbor • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.
Address 127.87.3.4 Te 1/16/1 Dell# 09:44:58/00:01:24 v2 Prio/Mode 1 / S show ip pim rp View all multicast groups-to-RP mappings. S6000–ON Syntax show ip pim [vrf vrf-name] rp [mapping | group-address] Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. mapping (OPTIONAL) Enter the keyword mapping to display the multicast groups-to-RP mapping and information on how RP is learnt.
RP: 50.40.4.4, v2 Dell# Example (Address) Dell#show ip pim rp 229.1.2.1 Group RP 229.1.2.1 165.87.20.4 show ip pim ssm-range Display the non-default groups added using the SSM range feature. S6000–ON Syntax show ip pim [vrf vrf-name] ssm-range Defaults none Command Modes Command History Exmaple • EXEC • EXEC Privilege Version Description 9.7(0.0) Introduced on the S6000-ON. Added support for VRF on S6000, S4810, S4820T, Z9000, Z9500, and S6000–ON. 9.5(0.0) Introduced on the Z9500. 9.0.2.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.4.1.1 Support for the display of PIM-SM snooping status was added on E-Series ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series.
show ip pim tib View the PIM tree information base (TIB). S6000–ON Syntax Parameters show ip pim [vrf vrf-name] tib [group-address [source-address]] vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. Command Modes Command History group-address (OPTIONAL) Enter the group address in dotted decimal format (A.B.C.D).
Field Example Description • C = directly connected • L = local to the multicast group • P = route was pruned • R = the forwarding entry is pointing toward the RP • F = Dell Networking OS is registering this entry for a multicast source • T = packets were received via Shortest Tree Path • J = first packet from the last hop router is received and the entry is ready to switch to SPT • K = acknowledge pending state Incoming interface Displays the reverse path forwarding (RPF) interface toward
39 Port Monitoring The port monitoring feature allows you to monitor network traffic by forwarding a copy of each incoming or outgoing packet from one port to another port. Important Points to Remember • Port monitoring is supported on physical ports and logical interfaces, such as port channels and virtual local area networks (VLANs). • The monitoring (destination, “MG”) and monitored (source, “MD”) ports must be on the same switch.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-7.7.1.0 Introduced on the E-Series. monitor session — enables a monitoring session. monitor multicast-queue Configure monitor QoS multicast queue ID.
monitor session Create a session for monitoring traffic with port monitoring. Syntax monitor session session-ID [type { rpm | erpm [set ip dscp dscp_value | set ip ttl ttl_value]}] [drop] To delete a session, use the no monitor session session-ID command. To delete all monitor sessions, use the no monitor session all command. Parameters session-ID Enter a session identification number. The range is from 0 to 65535.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information The monitor command is saved in the running configuration at Monitor Session mode level and can be restored after a chassis reload. Example Dell#show monitor session SessID Source Destination Dest IP DSCP TTL ------ -------------------------- --0 Te 1/12/1 remote-ip 7.1.1.2 0 255 0 Po 1 remote-ip 7.1.1.2 0 255 1 Vl 11 remote-ip 3.1.1.
show config Display the current monitor session configuration. Syntax show config Defaults none Command Modes MONITOR SESSION (conf-mon-sess-session-ID) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.0.0 Added support for the RPM / ERPM. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.
• For a VLAN interface enter the keyword VLAN followed by a number from 1 to 4094. • For a port channel interface, enter the keywords port-channel then a number. range Enter the keyword range to specify the list of interfaces. any Enter the keyword any to specify all interfaces. NOTE: This option is applicable only with drop monitor session. destination interface direction {rx | tx | both} Enter the keyword destination to specify the destination interface.
Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series.
40 Private VLAN (PVLAN) The private VLAN (PVLAN) feature of the Dell Networking operating software is supported on the platforms. Private VLANs extend the Dell Networking OS security suite by providing Layer 2 isolation between ports within the same private VLAN. A private VLAN partitions a traditional VLAN into subdomains identified by a primary and secondary VLAN pair. The Dell Networking OS private VLAN implementation is based on RFC 3069. For more information, refer to the following commands.
– A trunk port in a PVLAN is always tagged. – A trunk port in Tagged mode carries primary or secondary VLAN traffic. The tag on the packet helps identify the VLAN to which the packet belongs. – A trunk port can also belong to a regular VLAN (non-private VLAN). ip local-proxy-arp Enable/disable Layer 3 communication between secondary VLANs in a private VLAN.
private-vlan mode Set PVLAN mode of the selected VLAN to community, isolated, or primary. S6000–ON Syntax [no] private-vlan mode {community | isolated | primary} To remove the PVLAN configuration, use the no private-vlan mode {community | isolated | primary} command syntax. Parameters community Enter the keyword community to set the VLAN as a community VLAN. isolated Enter the keyword isolated to configure the VLAN as an isolated VLAN.
private-vlan mapping secondary-vlan Map secondary VLANs to the selected primary VLAN. S6000–ON Syntax [no] private-vlan mapping secondary-vlan vlan-list To remove specific secondary VLANs from the configuration, use the no private-vlan mapping secondary-vlan vlan-list command syntax. Parameters vlan-list Enter the list of secondary VLANs to associate with the selected primary VLAN. The list can be in comma-delimited or hyphenated-range format, following the convention for the range input.
switchport mode private-vlan Set PVLAN mode of the selected port. S6000–ON Syntax [no] switchport mode private-vlan {host | promiscuous | trunk} To remove PVLAN mode from the selected port, use the no switchport mode private-vlan command. Parameters host Enter the keyword host to configure the selected port or port channel as an isolated interface in a PVLAN. promiscuous Enter the keyword promiscuous to configure the selected port or port channel as an promiscuous interface.
Related Commands private-vlan mode — sets the mode of the selected VLAN to community, isolated, or primary. private-vlan mapping secondary-vlan — sets the mode of the selected VLAN to primary and then associates the secondary VLANs to it.
41 Per-VLAN Spanning Tree Plus (PVST+) The Dell Networking operating software implementation of per-VLAN spanning tree plus (PVST+) is based on the IEEE 802.1w standard spanning tree protocol. Dell Networking OS supports PVST+ on the S6000–ON platform. NOTE: For easier command line entry, the plus (+) sign is not used at the command line. description Enter a description of the PVST+. S6000–ON Syntax description {description} To remove the description, use the no description {description} command.
disable Disable PVST+ globally. S6000–ON Syntax disable To enable PVST+, use the no disable command. Defaults Disabled. Command Modes CONFIGURATION (conf-pvst) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced. Dell(conf-pvst)#do show spanning-tree pvst vlan 5 brief VLAN 5 Executing IEEE compatible Spanning Tree Protocol Root ID Priority 32773, Address 0001.e832.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 8.3.1.0 Introduced.
• guard Defaults For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. (OPTIONAL) Enter the keyword guard to display the type of guard enabled on a PVST interface and the current port state. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Configured hello time 2, max age 20, forward delay 15 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ---------------------------------------------------------Te 1/0/1 128.130 128 20000 FWD 20000 4096 0001.e801.6aa8 Te 1/1/1 128.131 128 20000 BLK 20000 4096 0001.e801.6aa8 Te 1/16/1 128.146 128 20000 FWD 20000 16384 0001.e805.e306 Te 1/17/1 128.147 128 20000 FWD 20000 16384 0001.e805.e306 128.426 128.427 128.146 128.
Edge port:no (default) port guard :none (default) Link type: point-to-point (auto) bpdu filter:disable (default) Bpdu guard :disable (default) Bpdus sent 152, received 27562 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ----------------------------------------------------------Te 1/1/1 128.1223 128 20000 EDS 0 32768 0001.e800.a12b 128.
err-disable Enter the keywords err-disable to enable the port to be put into the errordisable state (EDS) if an error condition occurs. vlan vlan-range Enter the keyword vlan then the VLAN numbers. The range is from 1 to 4094. cost number Enter the keyword cost then the port cost value. The range is from 1 to 200000. Defaults: • 100 Mb/s Ethernet interface = 200000. • 1-Gigabit Ethernet interface = 20000. • 10-Gigabit Ethernet interface = 2000.
Usage Information The BPDU guard option prevents the port from participating in an active STP topology in case a BPDU appears on a port unintentionally, or is misconfigured, or is subject to a DOS attack. This option places the port into the Error Disable state if a BPDU appears, and a message is logged so that the administrator can take corrective action. NOTE: A port configured as an edge port, on a PVST switch, immediately transitions to the forwarding state.
Defaults Enabled; ports are placed in the Err-Disabled state if they receive a PVST+ BPDU when they are members of an untagged VLAN. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced. By default, Dell Networking OS implements an optimized flush mechanism for PVST+.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. vlan forward-delay — changes the time interval before Dell Networking OS transitions to the Forwarding state. vlan hello-time — change the time interval between BPDUs. vlan max-age — changes the time interval before PVST+ refreshes. show spanning-tree pvst — displays the PVST+ configuration.
Related Commands Version Description 6.2.1.1 Introduced. vlan bridge-priority — sets the bridge-priority value. vlan hello-time — changes the time interval between BPDUs. vlan max-age — changes the time interval before PVST+ refreshes. show spanning-tree pvst — displays the PVST+ configuration. vlan hello-time Set the time interval between generation of PVST+ 7 BPDUs. S6000–ON Syntax vlan vlan-range hello-time seconds To return to the default value, use the no vlan hello-time command.
Related Commands vlan bridge-priority — sets the bridge-priority value. vlan forward-delay — changes the time interval before Dell Networking OS transitions to the forwarding state. vlan max-age — changes the time interval before PVST+ refreshes. show spanning-tree pvst — displays the PVST+ configuration. vlan max-age To maintain configuration information before refreshing that information, set the time interval for the PVST+ bridge.
vlan forward-delay — changes the time interval before Dell Networking OS transitions to the forwarding state. vlan hello-time — changes the time interval between BPDUs. show spanning-tree pvst — displays the PVST+ configuration.
42 Quality of Service (QoS) The Dell Networking operating software commands for quality of service (QoS) include traffic conditioning and congestion control. QoS commands are not universally supported on all Dell Networking Products. platform. This chapter contains the following sections: • Global Configuration Commands • Per-Port QoS Commands • Policy-Based QoS Commands Global Configuration Commands There is only one global configuration QoS command.
Version Description 8.3.1.0 Introduced. service-class bandwidth-percentage Specify a minimum bandwidth for queues. S6000–ON Syntax service-class bandwidth-percentage queue0 number queue1 number queue2 number queue3 number Parameters number Defaults none Command Modes CONFIGURATION Command History Usage Information Enter the bandwidth-weight, as a percentage. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Parameters unicast number Enter the keyword unicast then the queue number. The range is from 1 to 3. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. The dot1p-priority command changes the priority of incoming traffic on the interface. The system places traffic marked with a priority in the correct queue and processes that traffic according to its queue.
Version Description 8.3.7.0 Introduced on the S4810. Usage Information NOTE: Per Port rate police is supported for Layer 2 tagged and untagged switched traffic and for Layer 3 traffic. Per VLAN rate police is supported on only tagged ports with Layer 2 switched traffic. S-Series On one interface, you can configure the rate police command for a VLAN or you can configure the rate police command for an interface.
NOTE: When packets of size greater than 7000 bytes are expected to be received from the network, Dell Networking recommends that you configure the burst value to be more than 175 KB if you configured the rate shape. Such a setting ensures proper bandwidth sharing across queues. Related Commands rate-shape — shapes traffic output as part of the designated policy. service-class dynamic dot1p Honor all 802.
Usage Information To honor all incoming 802.1p markings on incoming switched traffic on the interface, enter this command. By default, this facility is not enabled (that is, the 802.1p markings on incoming traffic are not honored). You can apply this command on both physical interfaces and port channels.
Usage Information The unit of bandwidth percentage is 1%. If the sum of the bandwidth percentages given to all eight classes exceeds 100%, the bandwidth percentage automatically scales down to 100%. Related Commands qos-policy-output — creates a QoS output policy. buffer-stats-snapshot Enable the buffer statistics tracking utility and enter the Buffer Statistics Snapshot configuration mode. You must enable this utility to be able to configure the parameters for buffer statistics tracking.
match-any Determines how packets are evaluated when multiple match criteria exist. Enter the keywords match-any to determine that the packets must meet at least one of the match criteria in order to be a member of the class. class-map-name Enter a name of the class for the class map in a character format (32 character maximum). cpu-qos Enter the keyword cpu-qos to assign this Class Map to control plane traffic only (CoPP). layer2 Enter the keyword layer2 to specify a Layer 2 Class Map.
match mac vlan — configures a match criterion for a class map based on VLAN ID. service-queue — assigns a class map and QoS policy to different queues. show qos class-map — views the current class map information. clear qos statistics Clear qos statistics clears statistics from show qos statistics.
Parameters description Enter a description to identify the policies (80 characters maximum). Defaults none Command Modes CONFIGURATION (policy-map-input and policy-map-output; conf-qos-policy-in and conf-qos-policy-out; wred) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
set-color value (Optional) Enter the keyword set-color followed by a color value. Traffic that fulfills the match criteria is marked with the color value that you specify. The default value is Yellow. Defaults none Command Modes CLASS-MAP CONFIGURATION (config-class-map) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Added the ipv6 and ip-any options on the Z9000, S6000, S4820T, S4810, MXL. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Command Modes CLASS-MAP CONFIGURATION (config-class-map) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Added support for the ipv6 and ip-any options on the Z9000, S6000, S4820T, S4810, MXL. 9.2(1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information To access this command, enter the class-map command. After the class map is identified, you can configure the match criteria. Related Commands class-map — identifies the class map. match mac dot1p Configure a match criterion for a class map based on a dot1p value.
Parameters number Enter the VLAN ID. The range is from 1 to 4094. Defaults none Command Modes CLASS-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Version Description 8.3.7.0 Introduced on the S4810. Usage Information If the rate shape exists in both aggregate and per-queue qos-policy, minimum of 2 take effect. Some of all Queue-rate will not exceed aggregate. Related Commands policy-map-input — creates an input policy map. policy-map-output — creates an output policy map. policy-map-input Create an input policy map.
policy-map-output Create an output policy map. S6000–ON Syntax policy-map-output policy-map-name To remove a policy map, use the no policy-map-output policy-map-name command. Parameters policy-map-name Enter the name for the policy map in character format (32 characters maximum). Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
layer2 (OPTIONAL) Enter the keyword layer2 to specify a Layer 2 Class Map. The default is Layer 3. Defaults Layer 3 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information Use this command to specify the name of the output QoS policy. Once output policy is specified, rateshape, scheduler strict, bandwidth-percentage, and WRED can be defined. This command enables the qospolicy-output configuration mode—(conf-qos-policy-out).
Version Description 8.3.7.0 Introduced on the S4810. Usage Information The default burst size is 100Kb. If a different value is required, you must configure the burst size to the required value. Related Commands rate police — specifies traffic policing on the selected interface. qos-policy-input — creates a QoS output policy. rate-shape Shape traffic output as part of the designated policy.
service-policy input Apply an input policy map to the selected interface. S6000–ON Syntax service-policy input policy-map-name [layer2] To remove the input policy map from the interface, use the no service-policy input policymap-name [layer2] command. Parameters policy-map-name Enter the name for the policy map in character format (32 characters maximum). You can identify an existing policy map or name one that does not yet exist.
Parameters policy-map-name Enter the name for the policy map in character format (32 characters maximum). You can identify an existing policy map or name one that does not yet exist. Defaults none Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Usage Information After the IP DSCP bit is set, other QoS services can then operate on the bit settings. show qos class-map View the current class map information. S6000–ON Syntax show qos class-map [class-name] Parameters Defaults class-name (Optional) Enter the name of a configured class map. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
detail Defaults Command Modes Command History To view a policy map interface in detail, enter the keyword detail and optionally one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. none • EXEC • EXEC Privilege This guide is platform-specific.
7 Dell# Example (Summary IPv4) c7 q7 Dell#sho qos policy-map summary Interface policy-map-input policy-map-output Te 4/1/1 PM1 Te 4/2/1 PM2 PMOut Dell# show qos policy-map-input View the input QoS policy map details. S6000–ON Syntax show qos policy-map-input [policy-map-name] [class class-map-name] [qospolicy-input qos-policy-name] Parameters Defaults policy-map-name Enter the policy map name. class class-mapname Enter the keyword class then the class map name.
show qos policy-map-output View the output QoS policy map details. S6000–ON Syntax Parameters Defaults Command Modes Command History show qos policy-map-output [policy-map-name] [qos-policy-output qos-policyname] policy-map-name Enter the policy map name. qos-policy-output qos-policy-name Enter the keyword qos-policy-output then the QoS policy name. none • EXEC • EXEC Privilege This guide is platform-specific.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Example Dell#show qos qos-policy-output Qos-policy-output qosOut Rate-limit 50 50 peak 50 50 Wred yellow 1 Wred green 1 show qos statistics View QoS statistics.
Related Command Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. clear hardware stack-unit - Clear statistics from selected hardware components. show qos wred-profile View the WRED profile details. S6000–ON Syntax show qos wred-profile wred-profile-name Parameters Defaults wred-profile-name Enter the WRED profile name to view the profile details.
S6000–ON Syntax Parameters [No] Service-class buffer shared-threshold-weight {[queue0 number] || [queue1 number] || [queue2 number] || [queue3 number] || [queue4 number] || [queue5 number] || [queue6 number] || [queue7 number]} buffer Define the shared buffer settings shared-thresholdweight Specify the weight of a queue for the shared buffer space queue 0 to queue 7 Specify the queue number to which the WRED parameters apply number Enter a weight for the queue on the shared buffer as a number in th
Example shared-threshold-weight on the queue % of available shared buffer that can be consumed by the queue. 11 88.89% Dell(conf-if-te-1/8/1)#Service-class buffer shared-threshold-weight queue5 4 queue7 6 test cam-usage Check the Input Policy Map configuration for the CAM usage. S6000–ON Syntax test cam-usage service-policy input policy-map stack-unit {[number port-set portpipe number] | [all]} Parameters policy-map Enter the policy map name.
Field Description stack-unit Indicates the stack-unit slot number. Portpipe Indicates the portpipe number. CAM Partition The CAM space where the rules are added. Available CAM Indicates the free CAM space, in the partition, for the classification rules. NOTE: The CAM entries reserved for the default rules are not included in the Available CAM column; free entries, from the default rules space, cannot be used as a policy map for the classification rules.
max-dropprobability number Enter the keyword max-drop-probability followed by the maximum number of packets for the WRED profile. The range is from 0 to 100 KB Defaults none Command Modes CONFIGURATION (config-wred) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Defaults none Command Modes CONFIGURATION (conf-policy-map-in) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.
Parameters yellow | green Enter the keyword yellow for yellow traffic. A DSCP value of xxx110 and xxx100, xxx101 maps to yellow. Enter the keyword green for green traffic. A DSCP value of xxx0xx are green and DSCP 111111 are red packets. profile-name Enter your WRED profile name in character format (32 character maximum). Or use one of the five pre-defined WRED profile names. Pre-defined Profiles: wred_drop, wred-ge_y, wred_ge_g, wred_teng_y, wred_teng_.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820t. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. When you enable wred ecn, and the number of packets in the queue is below the minimum threshold, packets are transmitted per the usual WRED treatment.
Version Description 9.3.0.0 Introduced on the S6000 and Z9000 platforms Usage Information If the average queue size is more than the maximum threshold of WRED, the packet is dropped. If the average queue size is between the minimum and maximum threshold values, the decision to drop or queue the packet is taken based on the packet drop probability. The probability that a packet is dropped depends on the minimum threshold, maximum threshold, and mark probability denominator.
rate shape Define the rate-shaping method to be either as a measure of bytes or packets for each of the hierarchical QoS (HQoS) nodes at the leaf level to be applied to each queue. S6000–ON Syntax Parameters [no] rate-shape [kbps | pps] peak-rate [burst-KB/Packets] [committed [kbps | pps] committed-rate [burst-KB/Packets]] kbps Enter the keyword kbps to specify the committed rate limit in Kilobits per second (Kbps). Specify this value as a multiple of 64. The range is from 0 to 40000000.
Default Granularity for rate is Mbps unless you use the kbps option. Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Added support for committed rate and committed burst size, and for configuration of rate limits on the S6000 platform. If you specify the pps keyword after the rate-shape command, the peak rate, peak burst, committed rate and committed burst are all considered to be values as a measure of packets.
yellow Specify yellow (medium) drop precedence to a queue. pool0 Service-pool buffer 1 (default service-pool for PFC traffic) . pool1 Service-pool buffer 0 (default service-pool for lossy traffic). number Enter a weight for the queue as a number in the range of 1 to 15. This parameter applies only if you specify the green or yellow drop precedence. string Enter the WRED profile name. It is a string of up to 32 characters. Or use one of the five pre-defined WRED profile names.
DSCP Color Map Commands The DSCP color map allows you to set the number of specific DSCP values to yellow or red. Traffic marked as yellow delivers traffic to the egress queue which will either transmit the packet if it has available bandwidth or drop the packet due to no ability to send. Traffic marked as red (high drop precedence) is dropped. dscp Sets the number of specific DSCP values for a color map profile to yellow or red.
Example Dell(conf-dscp-color-map)# dscp yellow 9,10,11,13,15,16 Related Commands qos dscp-color-map — configures the DSCP color map qos dscp-color-policy— configures a DSCP color policy qos dscp-color-map Configure the DSCP color map. Syntax qos dscp-color-map map-name To remove a color map, use the no qos dscp-color-map map-name command. Parameters map-name Enter the name of the DSCP color map. The map name can have a maximum of 32 characters.
To remove a color policy map profile, use the no dscp-color-policy color-map-profile-name command. Parameters color-map-profilename Enter the color map profile name. The name can have a maximum of 32 characters. Defaults None Command Modes CONFIG-INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5.0.0 Introduced on the Z9000, S6000, S4820T, S4810, and MXL. Display summary information about a color policy on one or more interfaces. Dell# show qos dscp-color-policy summary Interface TE 1/10/1 TE 1/11/1 dscp-color-map mapONE mapTWO Display summary information about a color policy on a specific interface.
Dscp-color-map mapONE yellow 4,7 red 20,30 Dscp-color-map mapTWO yellow 16,55 Display a specific DSCP color map.
43 Routing Information Protocol (RIP) Routing information protocol (RIP) is a distance vector routing protocol. The Dell Networking operating software supports both RIP version 1 (RIPv1) and RIP version 2 (RIPv2) on the platform. The Dell Networking OS implementation of RIP is based on IETF RFCs 2453 and RFC 1058. For more information about configuring RIP, refer to the Dell Networking OS Configuration Guide.
clear ip rip Update all the RIP routes in the Dell Networking OS routing table. S6000–ON Syntax clear ip rip Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000.
database (OPTIONAL) Enter the keyword database to display messages when there is a change to the RIP database. events (OPTIONAL) Enter the keyword events to debug only RIP protocol changes. trigger (OPTIONAL) Enter the keyword trigger to debug only RIP trigger extensions. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information This command ensures that route information being redistributed is converted to the same metric value. Related Commands redistribute — allows you to redistribute routes learned by other methods. description Enter a description of the RIP routing protocol.
distance Assign a weight (for prioritization) to all routes in the RIP routing table or to a specific route. Lower weights (“administrative distance”) are preferred. S6000–ON Syntax distance weight [ip-address mask [prefix-name]] To return to the default values, use the no distance weight [ip-address mask] command. Parameters weight Enter a number from 1 to 255 for the weight (for prioritization). The default is 120. ip-address (OPTIONAL) Enter the IP address, in dotted decimal format (A.B.C.
To delete the filter, use the no distribute-list prefix-list-name in command. Parameters prefix-list-name Enter the name of a configured prefix list. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
To delete the filter, use the no distribute-list prefix-list-name out command. Parameters prefix-list-name Enter the name of a configured prefix list. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
ip poison-reverse Set the prefix of the RIP routing updates to the RIP infinity value. S6000–ON Syntax ip poison-reverse To disable poison reverse, use the no ip poison-reverse command. Defaults Disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information To enable the interface to send both version of RIP packets, use the ip rip send version 1 2 command.
Related Commands Version Description pre- 6.2.1.1 Introduced on the E-Series. ip poison-reverse — sets the prefix for RIP routing updates. maximum-paths Set RIP to forward packets over multiple paths. S6000–ON Syntax maximum-paths number To return to the default values, use the no maximum-paths commands. Parameters number Enter the number of paths. The range is from 1 to 16. The default is 4 paths. Defaults 4 Command Modes ROUTER RIP Command History This guide is platform-specific.
To delete a neighbor setting, use the no neighbor ip-address command. Parameters ip-address Enter the IP address, in dotted decimal format, of a router with which to exchange information. Defaults Not configured. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Defaults Not configured. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. This command is intended for low-speed interfaces. passive-interface Suppress routing updates on a specified interface.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information Although the passive interface does not send or receive routing updates, the network on that interface still includes in RIP updates sent using other interfaces.
Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information To redistribute the default route (0.0.0.0/0), configure the default-information originate command. Related Commands default-information originate — generates a default route for RIP traffic. redistribute isis Redistribute routing information from an IS-IS instance.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. pre- 6.2.1.1 Introduced on the E-Series. redistribute ospf Redistribute routing information from an OSPF process. S6000–ON Syntax redistribute ospf process-id [match external {1 | 2} | match internal | metric metric-value] [route-map map-name] To disable redistribution, use the no redistribute ospf process-id [match external {1 | 2} | match internal | metric metric-value] [route-map map-name] command.
Version Description 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. router rip To configure and enable RIP, enter ROUTER RIP mode. S6000–ON Syntax router rip To disable RIP, use the no router rip command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show config Display the changes you made to the RIP configuration. The default values are not shown. S6000–ON Syntax show config Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example 1140 Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
show running-config rip Display the current RIP configuration. S6000–ON Syntax show running-config rip Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000.
Defaults invalid Enter the number of seconds to specify the time interval before routing updates are declared invalid or expired. The invalid value should be at least three times the update timer value. The range is from zero (0) to 4294967295. The default is 180 seconds. holddown Enter the number of seconds to specify a time interval during which the route is marked as unreachable but still sending RIP packets. The holddown value should be at least three times the update timer value.
To return to the default version setting, use the no version command. Parameters 1 Enter the keyword 1 to specify RIP version 1. 2 Enter the keyword 2 to specify RIP version 2. Defaults The Dell Networking OS sends RIPv1 and receives RIPv1 and RIPv2. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
44 Remote Monitoring (RMON) The Dell Networking operating software remote monitoring (RMON) is implemented on the S6000–ON platform. Dell Networking OS RMON is based on IEEE standards, providing both 32-bit and 64-bit monitoring and long-term statistics collection.
interval Time, in seconds, the alarm monitors the MIB variables; this is the alarmSampleType in the RMON alarm table. The range is from 5 to 3600 seconds. delta Enter the keyword delta to test the change between MIB variables. This is the alarmSampleType in the RMON alarm table. absolute Enter the keyword absolute to test each MIB variable directly. This is the alarmSampleType in the RMON alarm table.
rmon collection history Enable the RMON MIB history group of statistics collection on an interface. S6000–ON Syntax rmon collection history {controlEntry integer} [owner name] [buckets number] [interval seconds] To remove a specified RMON history group of statistics collection, use the no rmon collection history {controlEntry integer} command. Parameters controlEntry integer Enter the keyword controlEntry to specify the RMON group of statistics using a value.
rmon collection statistics Enable RMON MIB statistics collection on an interface. S6000–ON Syntax rmon collection statistics {controlEntry integer} [owner name] To remove RMON MIB statistics collection on an interface, use the no rmon collection statistics {controlEntry integer} command. Parameters controlEntry integer Enter the keyword controlEntry to specify the RMON group of statistics using a value. Then enter an integer value from 1 to 65535 that identifies the RMON Statistic Table.
Parameters number Assign an event number in integer format. The range is from 1 to 65535. You must ensure that the value you enter is unique in the RMON event table. log (OPTIONAL) Enter the keyword log to generate an RMON event log. This option sets the eventType to either log or log-and-snmptrap in the RMON event table. The default is None. trap community (OPTIONAL) Enter the keyword trap followed by the SNMP community string to generate SNMP traps for an RMON event entry.
variable The MIB object to monitor. The variable must be in the SNMP OID format; for example, 1.3.6.1.2.1.1.3 The object type must be a 64-bit integer. interval Time, in seconds, the alarm monitors the MIB variables; this is the alarmSampleType in the RMON alarm table. The range is from 5 to 3600 seconds. delta Enter the keyword delta to test the change between MIB variables. This is the alarmSampleType in the RMON alarm table. absolute Enter the keyword absolute to test each MIB variable directly.
show rmon Display the RMON running status including the memory usage. S6000–ON Syntax show rmon Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
show rmon events Display the contents of the RMON event table. S6000–ON Syntax show rmon events [index] [brief] Parameters index (OPTIONAL) Enter the table index number to display just that entry. brief (OPTIONAL) Enter the keyword brief to display the RMON event table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
event owner: event status: OK RMON event entry 114 description: event type: LOG and SNMP TRAP. event community: public event last time sent: none event owner: event status: OK Example (Brief) Dell#show rmon event brief index description -----------------------------1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 Dell# show rmon hc-alarm Display the contents of RMON High-Capacity alarm table.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. Example (Index) Dell#show rmon hc-alarm 1 RMON high-capacity alarm entry 2 object: 1.3.6.1.2.1.2.2.1.4.2099844 sample interval: 10 sample type: delta value.
Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
brief (OPTIONAL) Enter the keyword brief to display the RMON log table in an easyto-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
brief (OPTIONAL) Enter the keyword brief to display the RMON Ethernet statistics table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example (Index) Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
HC 512-1023 bytes packets: 0 HC 1024-1518 bytes packets overflow: 0 HC 1024-1518 bytes packets: 0 Dell# Example (Brief) 1158 Dell#show rmon statistics br index ifIndex interface ---------------------------------------6001 100974631 TenGigabitEthernet 2/2/1 6002 100974631 TenGigabitEthernet 2/2/1 6003 101236775 TenGigabitEthernet 2/1/1 6004 101236775 TenGigabitEthernet 2/1/1 9001 134529054 TenGigabitEthernet 3/2/1 9002 134529054 TenGigabitEthernet 3/2/1 9003 134791198 TenGigabitEthernet 3/1/1 9004 13479119
45 Rapid Spanning Tree Protocol (RSTP) The Dell Networking operating software implementation of rapid spanning tree protocol (RSTP) is based on the IEEE 802.1w standard spanning-tree protocol. The RSTP algorithm configures connectivity throughout a bridged local area network (LAN) that is comprised of LANs interconnected by bridges. Dell Networking OS supports RSTP. bridge-priority Set the bridge priority for RSTP.
debug spanning-tree rstp Enable debugging of RSTP and view information on the protocol. Syntax debug spanning-tree rstp [all | bpdu interface {in | out} | events] To disable debugging, use the no debug spanning-tree rstp command. Parameters all (OPTIONAL) Enter the keyword all to debug all spanning tree operations. bpdu interface {in | out} (OPTIONAL) Enter the keyword bpdu to debug the bridge protocol data units.
description Enter a description of the rapid spanning tree. Syntax description {description} To remove the description, use the no description {description} command. Parameters description Enter a description to identify the rapid spanning tree (80 characters maximum). Defaults none Command Modes SPANNING TREE (The prompt is “config-rstp”.) Command History This guide is platform-specific.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. protocol spanning-tree rstp — enters SPANNING TREE mode on the switch. forward-delay Configure the amount of time the interface waits in the Listening State and the Learning State before transitioning to the Forwarding State.
hello-time Set the time interval between the generation of the RSTP bridge protocol data units (BPDUs). Syntax hello-time [milli-second] seconds To return to the default value, use the no hello-time command. Parameters seconds Enter a number as the time interval between transmission of BPDUs. The range is from 1 to 10 seconds. The default is 2 seconds. milli-second Enter the keywords milli-second to configure a hello time on the order of milliseconds.
max-age To maintain configuration information before refreshing that information, set the time interval for the RSTP bridge. Syntax max-age seconds To return to the default values, use the no max-age command. Parameters max-age Enter a number of seconds the Dell Networking OS waits before refreshing configuration information. The range is from 6 to 40 seconds. The default is 20 seconds.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information RSTP is not enabled when you enter RSTP mode.
no disable bridge-priority 16384 show spanning-tree rstp Display the RSTP configuration. Syntax show spanning-tree rstp [brief] [guard] Parameters Command Modes Command History Usage Information Example (Brief) 1166 brief (OPTIONAL) Enter the keyword brief to view a synopsis of the RSTP configuration information. guard (OPTIONAL) Enter the keyword guard to display the type of guard enabled on an RSTP interface and the current port state. • EXEC • EXEC Privilege Version Description 9.7(0.
Root ID Priority 8192, Address 0001.e805.e306 Root Bridge hello time 4, max age 20, forward delay 15 Bridge ID Priority 16384, Address 0001.e801.6aa8 Configured hello time 2, max age 20, forward delay 15 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ---------- ------- --- ------- -------------------- -------Te 4/2/1 128.418 128 20000 FWD 20000 16384 0001.e801.6aa8 128.418 Te 4/1/1 128.419 128 20000 FWD 20000 16384 0001.e801.6aa8 128.419 Te 4/8/1 128.426 128 20000 FWD 20000 8192 0001.
spanning-tree rstp Configure an RSTP interface with one of these settings: port cost, edge port with optional bridge port data unit (BPDU) guard, port priority, loop guard, or root guard. Syntax spanning-tree rstp {cost port-cost | edge-port [bpduguard [shutdown-onviolation]] | priority priority | {loopguard | rootguard}} Parameters cost port-cost Enter the keyword cost then the port cost value. The range is from 1 to 200000.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.4.2.1 Added support for the optional guard keyword on the C-Series, S-Series, and ESeries TeraScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced the hardware shutdown-on-violation options. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added the optional bridge port data unit (BPDU) guard. 6.2.1.1 Introduced on the E-Series.
tc-flush-standard Enable the MAC address flushing after receiving every topology change notification. Syntax tc-flush-standard To disable, use the no tc-flush-standard command. Defaults Disabled Command Modes CONFIGURATION (conf-rstp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
46 Security The commands in this chapter are available on Dell Networking OS. This chapter contains various types of security commands offered in the Dell Networking operating software. The commands are listed in the following sections: • AAA Accounting Commands • Authorization and Privilege Commands • Authentication and Password Commands • RADIUS Commands • TACACS+ Commands • Port Authentication (802.
commands {level | role role-name Enter the keyword command then a privilege level for accounting of commands executed at that privilege level or enter the keyword role then the role name for accounting of commands executed by a user with that user role. name | default Enter one of the following: • For name, enter a user-defined name of a list of accounting methods. • For default, the default accounting methods used.
Dell(conf)# aaa accounting command role secaadmin default start-stop tacacs + Related Commands enable password — changes the password for the enable command. login authentication — enables AAA login authentication on the terminal lines. password — creates a password. tacacs-server host — specifies a TACACS+ server host. aaa accounting suppress Prevent the generation of accounting records of users with the user name value of NULL.
accounting Apply an accounting method list to terminal lines. Syntax accounting {exec | commands {level | role role-name} method-list Parameters exec Enter the keyword exec to apply an EXEC level accounting method list. commands {level | role role-name} Enter the keywords commands level to apply an EXEC and CONFIGURATION level accounting method list by enter the keyword role and then the role name for accounting of commands executed by a user with that user role.
Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Introduced on the S-Series and Z-Series.
Version Description 6.3.1.0 Introduced on the E-Series. Usage Information This command steps through all active sessions and then displays the accounting records for the active account functions.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Introduced on the E-Series.
Version Description 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Added support for RADIUS. aaa authorization config-commands Set parameters that restrict (or permit) a user’s access to EXEC level commands.
To disable authorization checking for EXEC level commands, use the no aaa authorization exec command. Parameters name Define a name for the list of authorization methods. default Define the default list of authorization methods. local Use the authorization parameters on the system to perform authorization. tacacs+ Use the TACACS+ protocol to perform authorization. none Enter the keyword none to apply no authorization.
level level Enter the keyword level then a number for the access level. The range is from 0 to 15. Level 1 is EXEC mode and Level 15 allows access to all CLI modes and commands. reset Enter the keyword reset to return the security level to the default setting. command Enter the command’s keywords to assign the command to a certain access level. You can enter one or all of the keywords. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Obscure Password Commands To enable the obscure password, use the following commands.
Password obscuring masks the password and keys for display only but does not change the contents of the file. The string of asterisks is the same length as the encrypted string for that line of configuration. To verify that you have successfully obscured passwords and keys, use the show running-config command orshow startup-config command. If you are using role-based access control (RBAC), only the system administrator and security administrator roles can enable the service obscure-password command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series.
method ... method4 Enter one of the following methods: • enable: use the password the enable password command defines in CONFIGURATION mode. Not available if role-only is in use. • line: use the password the password command defines in LINE mode. Not available if role-only is in use. • local: use the password for the userid contained in the local password database. • none: no authentication. Not available if role-only is in use.
NOTE: If authentication fails using the primary method, Dell Networking OS employs the second method (or third method, if necessary) automatically. For example, if the TACACS+ server is reachable, but the server key is invalid, Dell Networking OS proceeds to the next authentication method. The TACACS+ is incorrect, but the user is still authenticated by the secondary method.
ip access-list extended — names (or selects) an extended access list based on the IP addresses or protocols. enable password Change the password for the enable command. Syntax enable password [level level] [encryption-type] password To delete a password, use the no enable password [encryption-type] password [level level] command. Parameters level level (OPTIONAL) Enter the keyword level then a number as the level of access. The range is from 1 to 15.
• Passwords can have a regular expression as the password. To create a password with a regular expression in it, use CNTL + v prior to entering regular expression. For example, to create the password abcd]e, you type “abcd CNTL v ]e”. When the password is created, you do not use the CNTL + v key combination and enter “abcd]e”. NOTE: The question mark (?) and the tilde (~) are not supported characters. Related Commands show running-config — views the current configuration.
enable secret Change the password for the enable command. Syntax enable secret [level level] [encryption-type] password To delete a password, use the no enable secret [encryption-type] password [level level] command. Parameters level level (OPTIONAL) Enter the keyword level then a number as the level of access. The range is from 1 to 15. encryption-type (OPTIONAL) Enter the number 5 or 0 as the encryption type. Enter a 5 then a text string as the hidden password.
abcd]e, you type “abcd CNTL v ]e”. When the password is created, you do not use the CNTL + v key combination and enter “abcd]e”. NOTE: The question mark (?) and the tilde (~) are not supported characters. Related Commands show running-config — views the current configuration. privilege level (CONFIGURATION mode) — controls access to the command modes within the switch. login authentication To configure authentication for console or remote access, apply an authentication method list.
Related Commands • If you configure the default authentication list using the default keyword, the list applies it to all the local and remote connections globally, unless you have specified some another authentication list for a specific connection. • If you configure an authentication lists other than default, you must apply those authentication lists to each connection.
Related Commands enable password — sets the password for the enable command. login authentication — configures an authentication method to log in to the switch. service password-encryption — encrypts all passwords configured in Dell Networking OS . radius-server key — configures a key for all RADIUS communications between the switch and the RADIUS host server. tacacs-server key — configures a key for communication between a TACACS+ server and client.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.0) Introduced lockout-period option on the Z9000, S6000, S4820T, S4810, and MXL. 9.2(1.0) Introduced on the Z9500. 9.0.2.
Version Description pre-6.1.1.0 Introduced on the E-Series. Usage Information CAUTION: Encrypting passwords with this command does not provide a high level of security. When the passwords are encrypted, you cannot return them to plain text unless you re-configure them. To remove an encrypted password, use the no password password command. To keep unauthorized people from viewing passwords in the switch configuration file, use the service password-encryption command.
show users Allows you to view information on all users logged in to the switch. Syntax show users [all] Parameters all (OPTIONAL) Enter the keyword all to view all terminal lines in the switch. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
6 idle 7 idle Dell# Related Commands vty 4 admin 10.16.127.141 vty 5 ad 10.16.127.141 unassigned 1 unassigned 15 username — enables a user. timeout login response Specify how long the software waits for the login input (for example, the user name and password) before timing out. Syntax timeout login response seconds To return to the default values, use the no timeout login response command. Parameters seconds Enter a number of seconds the software waits before logging you out.
username Establish an authentication system based on user names. Syntax username name [access-class access-list-name] [nopassword | {password | secret} [encryption-type] password] [privilege level] [role role-name] If you do not want a specific user to enter a password, use the nopassword option. To delete authentication for a user, use the no username name command. Parameters name Enter a text string for the name of the user up to 63 characters.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Added support for the secret option and the MD5 password encryption. Extended the name from 25 to 63 characters. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information To view the defined user names, use the show running-config user command.
Version Description pre-6.2.1.0 Introduced on the E-Series. ip radius source-interface Specify an interface’s IP address as the source IP address for RADIUS connections. Syntax ip radius source-interface interface To delete a source interface, use the no ip radius source-interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
radius-server deadtime Configure a time interval during which non-responsive RADIUS servers to authentication requests are skipped. Syntax radius-server deadtime seconds To disable this function or return to the default value, use the no radius-server deadtime command. Parameters seconds Enter a number of seconds during which non-responsive RADIUS servers are skipped. The range is from 0 to 2147483647 seconds. The default is 0 seconds.
Version Description 9.4.(0.0) Introduced on the S-Series and Z-Series. Example Dell(conf)#radius-server group group1 Dell(conf-radius-group)#radius-server host 1.1.1.1 key secret Dell(conf-radius-group)#radius-server host 2.2.2.2 key secret Dell(conf-radius-group)#radius-server vrf vrf1 source-interface tengigabitethernet 1/3/1 Dell(conf-radius-group)#show config ! radius-server group group1 radius-server vrf vrf1 source-interface TenGigabitEthernet 1/3/1 radius-server host 1.1.1.
• 7 means that the password is encrypted and hidden. Configure this parameter last because leading spaces are ignored. Defaults Command Modes Command History Not configured. • RADIUS SERVER GROUP • CONFIGURATION This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Example Dell(conf)#radius-server group group1 Dell(conf-radius-group)#radius-server host 1.1.1.1 key secret Dell(conf-radius-group)#no radius-server host 1.1.1.1 Related Commands login authentication — sets the database to be checked when a user logs in. radius-server key — sets an authentication key for RADIUS communications. radius-server retransmit — sets the number of times the RADIUS server attempts to send information.
Usage Information You can use this command to associate a group of RADIUS servers with a VRF and source interface. You can configure the source interface only with the VRF attribute and source interface is optional with the VRF attributes. If VRF is not configured on the RADIUS group, then the group is considered to be on the default VRF.
Usage Information Version Description 7.7.1.0 Authentication key length increased to 42 characters. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. The key configured on the switch must match the key configured on the RADIUS server daemon. If you configure the key parameter in the radius-server host command, the key configured with the radius-server key command is the default key for all RADIUS communications.
radius-server timeout To reply to a request, configure the amount of time the RADIUS client (the switch) waits for a RADIUS host server . Syntax radius-server timeout seconds To return to the default value, use the no radius-server timeout command. Parameters seconds Enter the number of seconds between an unsuccessful attempt and the Dell Networking OS times out. The range is from zero (0) to 1000 seconds. The default is 5 seconds.
Parameters group-name Enter the name of the TACACS server group. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Introduced on the S-Series and Z-Series.
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. ip tacacs source-interface Specify an interface’s IP address as the source IP address for TACACS+ connections. Syntax ip tacacs source-interface interface To delete a source interface, use the no ip tacacs source-interface command.
tacacs-server group Creates a group of TACACS servers. Syntax tacacs-server group group-name To delete a group of TACACS servers, use the no tacacs-server group group-name command. Parameters group-name Enter the name of the TACACS server group. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
timeout seconds (OPTIONAL) Enter the keyword timeout then the number of seconds the switch waits for a reply from the TACACS+ server. The range is from 0 to 1000. The default is 10 seconds. key key (OPTIONAL) Enter the keyword key then a string up to 42 characters long as the authentication key. This authentication key must match the key specified in the tacacs-server key for the TACACS+ daemon. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Example Dell(conf)#tacacs-server group group1 Dell(conf-tacacs-group)#tacacs-server host 1.1.1.1 key secret Dell(conf-tacacs-group)#no tacacs-server host 1.1.1.1 Related Commands aaa authentication login — specifies the login authentication method. tacacs-server key — configures a TACACS+ key for the TACACS server. tacacs-server key Configure a key for communication between a TACACS+ server and a client.
tacacs-server vrf Create an association between a TACACS server group and a VRF and source interface. Syntax tacacs-server vrf vrf-name [source-interface interface] To delete the association between a TACACS server group and a VRF and source interface, use the no tacacs-server vrf vrf-name [source-interface interface] command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to associate a TACACS server group with that VRF.
Dell(conf-tacacs-group)#tacacs-server vrf default Port Authentication (802.1X) Commands An authentication server must authenticate a client connected to an 802.1X switch port. Until the authentication, only Extensible Authentication Protocol over LAN (EAPOL) traffic is allowed through the port to which a client is connected. After authentication is successful, normal traffic passes through the port. Dell Networking OS supports RADIUS and Active Directory environments using 802.1X Port Authentication.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x authentication (Interface) — enables dot1x on an interface. dot1x authentication (Interface) Enable dot1x on an interface; dot1x must be enabled both globally and at the interface level. Syntax dot1x authentication To disable dot1x on an interface, use the no dot1x authentication command.
Defaults 3 attempts Command Modes CONFIGURATION (conf-if-interface-slot/port[/subport]) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.
Version Description 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x guest-vlan Configure a guest VLAN for limited access users or for devices that are not 802.1X capable. Syntax dot1x guest-vlan vlan-id To disable the guest VLAN, use the no dot1x guest-vlan vlan-id command. Parameters vlan-id Enter the VLAN Identifier. The range is from 1 to 4094. Defaults Not configured.
show dot1x interface — displays the 802.1X information on an interface. dot1x mac-auth-bypass Enable MAC authentication bypass. If 802.1X times out because the host did not respond to the Identity Request frame, Dell Networking OS attempts to authenticate the host based on its MAC address. Syntax [no] dot1x mac-auth-bypass Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. interface range — configures a range of interfaces. dot1x port-control Enable port control on an interface.
Parameters seconds Enter the number of seconds. The range is from 1 to 65535. The default is 30. Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Related Commands Version Description 7.4.1.0 Introduced on the E-Series. interface range — configures a range of interfaces. dot1x reauth-max Configure the maximum number of times a port can re-authenticate before the port becomes unauthorized. Syntax dot1x reauth-max number To return to the default, use the no dot1x reauth-max command. Parameters number Enter the permitted number of re-authentications. The range is from 1 to 10. The default is 2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.
dot1x tx-period Configure the intervals at which EAPOL PDUs are transmitted by the Authenticator PAE. Syntax dot1x tx-period seconds To return to the default, use the no dot1x tx-period command. Parameters seconds Enter the interval time, in seconds, that EAPOL PDUs are transmitted. The range is from 1 to 65535 (1 year). The default is 30. Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.
ReAuth Max: Supplicant Timeout: Server Timeout: Re-Auth Interval: Max-EAP-Req: Host Mode: Auth PAE State: Backend State: Dell# 2 30 seconds 30 seconds 3600 seconds 2 SINGLE_HOST Initialize Initialize SSH Server and SCP Commands Dell Networking OS supports secure shell (SSH) protocol versions 1.5 and 2.0. SSH is a protocol for secure remote login over an insecure network. SSH sessions are encrypted and use authentication. crypto key generate Generate keys for the SSH server.
Usage Information Version Description pre-6.1.1.0 Introduced on the E-Series. The host keys are required for key-exchange by the SSH server. If the keys are not found when you enable the server (ip This command requires user interaction and generates a prompt prior to overwriting any existing host keys. NOTE: Only a user with superuser permissions should generate host-keys. Example Dell(conf)#crypto key generate rsa Enter key size <1024-2048>. Default<1024> : Host key already exists.
server Enter the keyword server to enable collecting debug information on the server. Defaults Disabled on both client and server. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information To configure the switch as an SCP server, use the ip ssh server command. Related Commands ip ssh server — enables the SSH and SCP server on the switch. ip ssh authentication-retries Configure the maximum number of attempts that should be used to authenticate a user.
Defaults 10 per minute Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Usage Information Version Description pre-6.1.1.0 Introduced on the E-Series. If you enable this command, clients can log in without a password prompt. This command provides two levels of authentication: • rhost-authentication is done with the file specified in the ip ssh rhostfile command. • checking client host-keys is done with the file specified in the ip ssh pub-key-file command. NOTE: Administrators must specify the two files (rhosts and pub-key-file) to configure host-based authentication.
ip ssh password-authentication Enable password authentication for the SSH server. Syntax ip ssh password-authentication enable To disable password-authentication, use the no ip ssh password-authentication enable command. Parameters enable Enter the keyword enable to enable password-authentication for the SSH server. Defaults Enabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Defaults The default time is 60 minutes. The default volume is 1024 megabytes. Command Modes CONFIGURATION mode Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.
+DWEc3cgYAcU5Lai1MU2ODrzhCwyDNp05tKBU3t ReG1o8AxLi6+S4hyEMqHzkzBFNVqHzpQc +Rs4p2urzV0F4pRKnaXdHf3Lk4D460HZRhhVrxqeNxPDpEn WIMPJi0ds= ashwani@poclab4 NOTE: For rhostfile and pub-key-file, the administrator must FTP the file to the chassis. Example Dell#conf Dell(conf)# ip ssh pub-key-file flash://knownhosts Dell(conf)# Related Commands show ip ssh client-pub-keys — displays the client-public keys used for the host-based authentication.
ip ssh rsa-authentication (Config) Enable RSA authentication for the SSHv2 server. Syntax ip ssh rsa-authentication enable To disable RSA authentication, use the no ip ssh rsa-authentication enable command. Parameters enable Enter the keyword enable to enable RSA authentication for the SSHv2 server. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Parameters enable Enter the key word enable to start the SSH server. ciphers cipher-list Enter the keyword ciphers and then a space-delimited list of ciphers that the SSH server supports. The following ciphers are available. • 3des-cbc • aes128-cbc • aes192-cbc • aes256-cbc • aes128-ctr • aes192-ctr • aes256-ctr The default cipher list is used.
kex key-exchangealgorithm Enter the keyword kex and then a space-delimited list of key exchange algorithms supported by the SSH server. The following key exchange algorithms are available: • diffie-hellman-group-exchange-sha1 • diffie-hellman-group1-sha1 • diffie-hellman-group14-sha1 When FIPS is enabled, the default key-exchange-algorithm is diffie-hellmangroup14-sha1.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. This command enables the SSH server and begins listening on a port. If a port is not specified, listening is on SSH default port 22. NOTE: Starting with Dell Networking OS Release 9.2(0.0), SSH server is enabled by default.
Usage Information You can enable the SSH server on either a management VRF or a user defined VRF but not both. If no VRF is specified, then the SSH server is enabled on the default VRF. If the SSH server is enabled on a VRF with name vrf1, then use the following command to restart the SSH server on a VRF with name vrf2: ip ssh server vrf vrf2. If the SSH server is enabled on a VRF with name vrf1, then use the following command to restart the SSH server on the default VRF: ip ssh server vrf.
Usage Information The source-interface interface attribute is applicable for both the SSH client as well as the COPY (SCP) commands. Using these attributes the client session tags an error to the user during run time, in case there is a mismatch between this command and the ip ssh vrf command. Example Dell(conf)#ip ssh source-interface tengigabitethernet 1/30/1 Dell(conf)#do ssh 10.10.10.2 -l admin Dell(conf)#no ip ssh source-interface ip ssh vrf Specify a VRF for an outgoing SSH connections.
rsa Enter the keyword rsa to display the host SSHv2 RSA public key. rsa1 Enter the keyword rsa1 to display the host SSHv1 RSA public key. NOTE: If you enable FIPS mode, this parameter is not available. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Example Dell#show ip ssh SSH server : enabled. SSH server version : v1 and v2. SSH server vrf : default.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information This command displays the contents of the flash://ADMIN_DIRssh/knownhosts file. Example Dell# show ip ssh client-pub-keys 4.8.1.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information This command displays the contents of the flash:/ADMIN_DIR/ssh/authorized-keys.username file.
-l username (OPTIONAL) Enter the keyword -l then the user name used in this SSH session. The default is the user name of the user associated with the terminal. -m HMAC algorithm Enter one of the following HMAC algorithms to use. (For v2 clients only): "no fips mode enable"(disable) will support v1 & v2 client. • hmac-md5: Force ssh to use hmac-md5 HMAC algorithm. • hmac-md5-96: Force ssh to use hmac-md5-96 HMAC algorithm. • hmac-sha1: Force ssh to use hmac-sha1 HMAC algorithm.
[anvltest@dt-maa-linux-1 ~]# exit logout Dell# Secure DHCP Commands DHCP as defined by RFC 2131 provides no authentication or security mechanisms. Secure DHCP is a suite of features that protects networks that use dynamic address allocation from spoofing and attacks. clear ip dhcp snooping Clear the DHCP binding table. Syntax clear ip dhcp snooping binding Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. ip dhcp snooping Enable DHCP Snooping globally. Syntax [no] ip dhcp snooping Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
interface type Defaults Command Modes Command History Enter the keyword interface then the type of interface to which the host is connected. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. slot/port Enter the slot and port number of the interface.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. ip dhcp snooping trust Configure an interface as trusted.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. ip dhcp snooping vlan Enable DHCP Snooping on one or more VLANs. Syntax Parameters [no] ip dhcp snooping vlan name name Enter the name of a VLAN on which to enable DHCP Snooping. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Command History Usage Information Version Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9000, S6000, S4820T, S4810, and MXL. By default, access to commands are determined by the user’s role (if defined) or by the user’s privilege level. If the aaa authorization role-only command is enabled, then only the user’s role is used. Before you enable role-based only AAA authorization: Related Commands 1. Locally define a system administrator user role.
reset Enter the keyword reset to reset all roles back to default for that command. command Enter the command’s keywords to assign the command to a certain access level. You can enter one or more keywords. Defaults none Command Modes CONFIGURATION Command History Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9000, S6000, S4820T, S4810, and MXL.
show userroles Display information on all defined user roles. Syntax show userroles Example Dell#show userroles Role Inheritance netoperator netadmin secadmin sysadmin netoperator testadmin Command Modes Command History Related Commands netadmin Modes Exec Exec Config Interface Line Router IP Route-map Protocol MAC Exec Config Exec Config Interface Line Router IP Route-map Protocol MAC Exec Config Interface Line Router IP Route-map Protocol MAC EXEC Privilege Version Description 9.7(0.
NOTE: You can change user role permissions on system pre-defined user roles or user-defined user roles. Important Points to Remember Consider the following when creating a user role: • Only the system administrator and user-defined roles inherited from the system administrator can create roles and usernames. Only the system administrator, security administrator, and roles inherited from these can use the role command to modify command permissions.
47 Service Provider Bridging Service provider bridging is composed of virtual local area network (VLAN) Stacking, Layer 2 Protocol Tunneling, and Provider Backbone Bridging as described in the Dell Networking OS Configuration Guide Service Provider Bridging chapter. This chapter includes command line information (CLI) for the Dell Networking operating software Layer 2 Protocol Tunneling (L2PT). L2PT enables protocols to tunnel through an 802.1q tunnel. Dell Networking OS supports L2PT on Dell Networking OS.
• For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. in | out | both Enter the keyword in, out, or both to debug incoming interfaces, outgoing interfaces, or both incoming and outgoing interfaces. vlan vlan-id Enter the keyword vlan then the VLAN ID. The range is from 1 to 4094. count value Enter the keyword count then the number of debug outputs. The range is from 1 to 100. Defaults Debug disabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guid. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.5.1.1 Added support for 802.1X, E-LMI, GMRP, GVRP, LLDP, LACP, MMRP, MVRP, and OAM 802.
Version Description 7.4.1.0 Introduced Usage Information When you enable VLAN-Stacking, no protocol packets are tunneled. Related Command show protocol-tunnel — displays tunneling information for all VLANs. protocol-tunnel enable Enable protocol tunneling globally on the system. Syntax protocol-tunnel enable To disable protocol tunneling, use the no protocol-tunnel enable command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series, E-Series and E-Series ExaScale. 7.4.1.
48 sFlow The Dell Networking operating software (OS) supports sFlow commands on Dell Networking OS. Dell Networking operating software sFlow monitoring system includes an sFlow Agent and an sFlow Collector. • The sFlow Agent combines the flow samples and interface counters into sFlow datagrams and forwards them to the sFlow Collector. • The sFlow Collector analyses the sFlow Datagrams received from the different devices and produces a network-wide view of traffic flows.
To delete a configured collector, use the no sflow collector {ip-address | ipv6-address} agent-addr {ipv4-address | ipv6-address} [number [max-datagram-size number]] | [max-datagram-size number] [vrf management] command. Parameters sflow collector ipaddress | ipv6address Enter the IP address of the collector in dotted decimal format for IPv4 or x:x:x:x::x format for IPv6.
Usage Information Version Description 6.2.1.1 Introduced on the E-Series. You can configure up to two sFlow collectors (IPv4 or IPv6). If two collectors are configured, traffic samples are sent to both. The sFlow agent address is carried in a field in SFlow packets and is used by the collector to identify the sFlow agent. In sFlow, the agent address is a single invariant IPv4 or IPv6 address used to identify the agent to the collector.
Version Description 7.6.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information sFlow is disabled by default. In addition to this command, sFlow needs to be enable on individual interfaces where sFlow sampling is desired. Related Commands sflow enable (Interface) — enables sFlow on interfaces. sflow ingress-enable Enable sFlow ingress on interfaces. Syntax sflow ingress-enable To disable sFlow, use the no sflow ingress enable command. Defaults Disabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S Series and Z Series switches. Dell(conf)#sflow max-header-size extended sflow polling-interval (Global) Set the sFlow polling interval at a global level. Syntax sflow polling-interval interval value To return to the default, use the no sflow polling-interval interval command. Parameters interval value Enter the interval value in seconds. The range is from 15 to 86400 seconds. The default is 20 seconds.
sflow polling-interval (Interface) Set the sFlow polling interval at an interface (overrides the global-level setting.) Syntax sflow polling-interval interval value To return to the default, use the no sflow polling-interval interval command. Parameters interval value Enter the interval value in seconds. The range is from 15 to 86400 seconds. The default is the global counter polling interval. Defaults The same value as the current global default counter polling interval.
Defaults 32768 packets Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.
49 Simple Network Management Protocol (SNMP) and Syslog This chapter contains commands to configure and monitor the simple network management protocol (SNMP) v1/v2/v3 and Syslog. Both features are supported on Dell Networking OS. The chapter contains the following sections: • SNMP Commands • Syslog Commands SNMP Commands The following SNMP commands are available in the Dell Networking OS.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. Example Dell#show snmp engineID Local SNMP engineID: 0000178B02000001E80214A8 Remote Engine ID IP-addr Port 80001F88043132333435 172.31.1.3 5009 80001F88043938373635 172.31.1.
Example Dell#show snmp group groupname: v1v2creadg readview : v1v2cdefault notifyview: v1v2cdefault row status: active Dell# Related Commands security model: v1 writeview: no write view specified context: no context specified snmp-server group — configures an SNMP server group. show snmp user Display the information configured on each SNMP user name. Syntax show snmp user Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
ipv6 access-listname (Optional) Enter the keyword ipv6 then an IPv6 ACL name (a string up to 16 characters long). security-name name (Optional) Enter the keywords security-name then the security name as defined by the community MIB. access-list-name (Optional) Enter a standard IPv4 access list name (a string up to 16 characters long). Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
Example Dell#config Dell(conf)# snmp-server community public ro Dell(conf)# snmp-server community guest ro security-name guestuser Dell(conf)# Example Dell(conf)# ip access-list standard snmp-ro-acl Dell(config-std-nacl)#seq 5 permit host 10.10.10.224 Dell(config-std-nacl)#seq 10 deny any count ! Dell(conf)#snmp-server community guest ro snmp-ro-acl Dell(conf)# Related Commands ip access-list standard — names (or selects) a standard access list to filter based on IP address.
snmp-server enable traps Enable SNMP traps. Syntax snmp-server enable traps [notification-type] [notification-option] To disable traps, use the no snmp-server enable traps [notification-type] [notification-option] command. Parameters notification-type notification-option Enter the type of notification from the following list: • bgp — Notification of changes in the BGP process. • config — Notification of changes to the startup or running configuration. • ecfm — Notification of changes to ECFM.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.8(0.0) Added the following two SNMP notification options: syslog-reachable and syslog-unreachable. 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Added support for copy-config and ECMP traps. 8.3.19.0 Introduced on the S4820T. 8.3.11.
udp-port portnumber engineID Enter the keywords udp-port followed by the user datagram protocol (UDP) port number on the remote device. The range is from 0 to 65535. The default is 162. Defaults As above. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
access-list-name | ipv6 access-list-name | access-list-name ipv6 accesslist-name]] command. Parameters group_name 1 | 2c | 3 Enter a text string (up to 20 characters long) as the name of the group. The following groups are created for mapping to read/write community/security-names (defaults): • v1v2creadg — maps to a community/security-name with ro permissions. • 1v2cwriteg — maps to a community/security-name rw permissions.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.2 Added support for the access parameter. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series.
version 1 | 2c | 3 (OPTIONAL) Enter the keyword version to specify the security model then the security model version number 1, 2c, or 3: • Version 1 is the least secure version. • Version 3 is the most secure of the security modes. • Version 2c allows transmission of informs and counter 64, which allows for integers twice the width of what is normally allowed. The default is version 1. auth (OPTIONAL) Enter the keyword auth to specify authentication of a packet without encryption.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Added support for config and ecmp traps. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Related Commands 3. Configure a group for this user with access rights. 4. Enable traps. 5. Configure a host to receive informs. snmp-server enable traps — enables SNMP traps. snmp-server community — configures a new community SNMPv1 or SNMPv2c. snmp-server location Configure the location of the SNMP server. Syntax snmp-server location text To delete the SNMP location, use the no snmp-server location command. Parameters text Enter an alpha-numeric text string, up to 55 characters long.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information To enable this snmp-server trap-source command, configure an IP address on the interface and enable the interface configured as an SNMP trap source.
• 2c allows transmission of informs and counter 64, which allows for integers twice the width of what is normally allowed. The default is 1. encrypted (OPTIONAL) Enter the keyword encrypted to specify the password appear in encrypted format (a series of digits, masking the true characters of the string). auth (OPTIONAL) Enter the keyword auth to specify authentication of a packet without encryption. md5 | sha (OPTIONAL) Enter the keyword md5 or sha to designate the authentication level.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. NOTE: For IPv6 ACLs, only IPv6 and UDP types are valid for SNMP. TCP and ICMP rules are not valid for SNMP. In IPv6 ACLs port rules are not valid for SNMP. No default values exist for authentication or privacy algorithms and no default password exists.
| sha} auth-password] [priv {des56 | aes128–cfb} priv-password] [access access-list-name | ipv6 access-list-name | access-list-name ipv6 accesslist-name] command. Parameters auth-password (OPTIONAL) Enter a text string (up to 20 characters long) password that enables the agent to receive packets from the host and to send packets to the host. Minimum: eight characters long. aes128 (OPTIONAL) Enter the keyword aes128 to initiate the AES128-CFB encryption algorithm for transmission of SNMP packets.
included (OPTIONAL) Enter the keyword included to include the MIB family in the view. excluded (OPTIONAL) Enter the keyword excluded to exclude the MIB family in the view. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S-Series and Z9000. Usage Information Use this command to bind an SNMP agent to a VRF. The SNMP agent processes the requests from the interfaces that belong to the specified VRF. If no VRF is specified, then the default VRF is used. Related Commands show snmp user — displays the information configured on each SNMP user name.
clear logging Clear the messages in the logging buffer. Syntax clear logging Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2(0.
Example Dell(conf)#clear logging auditlog Related Commands show logging auditlog — displays audit log default logging buffered Return to the default setting for messages logged to the internal buffer. Syntax default logging buffered Defaults size = 40960; level = 7 or debugging Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Related Commands logging console — sets the logging console parameters. default logging monitor Return to the default settings for messages logged to the terminal. Syntax default logging monitor Defaults level = 7 or debugging Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Version Description 9.5(0.0) Added udp and tcp keywords for the S4810, S4820T, S6000, Z9000, and MXL. 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.4.1.0 Added support for IPv6. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information When you decrease the buffer size, all messages stored in the buffer are lost.
Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Related Commands clear logging — clears the logging buffer. default logging console — returns the logging console parameters to the default setting.
Examples Dell(conf)#logging extended Related Commands show logging auditlog — displays audit log, clear logging auditlog— clears audit log logging facility Configure the Syslog facility used for error messages sent to Syslog servers. Syntax logging facility [facility-type] To return to the default values, use the no logging facility command.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Related Commands logging — enables logging to a Syslog server. logging on — enables logging.
Version Description E-Series legacy command Usage Information When you configure the snmp-server trap-source command, the system messages logged to the history table are also sent to the SNMP network management station. Related Commands show logging — displays information logged to the history buffer. logging history size Specify the number of messages stored in the Dell Networking logging history table.
logging monitor Specify which messages are logged to Telnet applications. Syntax logging monitor [level] To disable logging to terminal connections, use the no logging monitor command. Parameters level Indicate a value from 0 to 7 or enter one of the following parameters: emergencies, alerts, critical, errors, warnings, notifications, informational, or debugging. The default is 7 or debugging. Defaults 7 or debugging Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
• For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator.
limit number-ofbuffers Enter the keyword limit then the number of buffers to be queued for the terminal after which new messages are dropped. The range is from 20 to 300. The default is 20. Defaults Disabled. If enabled without the level or number-of-buffers options specified, level = 2 and numberof-buffers = 20 are the defaults. Command Modes LINE Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series, S55. 7.5.1.
• Example 1 – Displays SYSLOG message format as described in RFC 5424, The Syslog Protocol Dell(conf)#logging version ? <0-1> Select syslog version (default = 0) Dell(conf)#logging version 1 show logging auditlog Displays an audit log. Syntax show logging auditlog Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
%RPM:0:0 %CHMGR-2-LINECARDDOWN - Line card 3 down - IPC timeout Dell# show logging driverlog stack-unit Display the driver log for the specified stack member. Syntax show logging driverlog stack-unit stack-unit-number Parameters defaults stack-unit stackunit-number Enter the keywords stack-unit followed by the stack member ID of the switch for which you want to display the driver log. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series.
50 SNMP Traps This chapter lists the traps sent by the Dell Networking operating software. Each trap is listed by the fields Message ID, Trap Type, and Trap Option. Message ID Trap Type Trap Option COLD_START SNMP COLDSTART WARM_START SNMP WARMSTART COPY_CONFIG_COMPLETE SNMP NONE SNMP LINKDOWN SNMP LINKUP SNMP AUTH EGP_NEIGHBOR_LOSS SNMP NONE OSTATE_DOWN SNMP LINKDOWN SNMP LINKUP SNMP NONE SNMP NONE SNMP NONE SNMP NONE %SNMP-5-SNMP_COLD_START: SNMP COLD_START trap sent.
Message ID Trap Type Trap Option SNMP NONE SNMP NONE SNMP NONE NONE NONE ENVMON NONE ENVMON NONE ENVMON NONE CHM_CARD_PROBLEM ENVMON NONE CHM_ALARM_CUTOFF ENVMON NONE CHM_SFM_UP ENVMON NONE CHM_SFM_DOWN ENVMON NONE CHM_RPM_UP ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE %RPM0-P:CP %SNMP-4-RMON_HC_FALLING_THRESHOLD: RMON highcapacity falling threshold alarm from SNMP OID BER_ERR %IFMGR-5-BER_ERR: High Ber detected on interface : %s BER_ERR_CLR %IFMGR-5-BER_ERR_C
Message ID Trap Type Trap Option CHM_SFM_REMOVE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON TEMP ENVMON TEMP ENVMON TEMP ENVMON TEMP ENVMON FAN %TSM-5-SFM_REMOVE: Removed SFM 1 CHM_MAJ_SFM_DOWN %CHMGR-0-MAJOR_SFM: Major alarm: Switch fabric down CHM_MAJ_SFM_DOWN_CLR %CHMGR-5-MAJOR_SFM_CLR: Major alarm cleared: Switch fabric up CHM_MIN_SFM_DOWN %CHMGR-2-MINOR_SFM: MIn
Message ID Trap Type Trap Option ENVMON FAN ENVMON FAN ENVMON FAN ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE For E1200: %CHMGR-2-FAN_TRAY_BAD: Major alarm: fan tray %d is missing or down %CHMGR-2-ALL_FAN_BAD: Major alarm: all fans in fan tray %d are down.
Message ID Trap Type Trap Option ENVMON NONE ENVMON NONE ENVMON NONE PROTO NONE PROTO NONE PROTO NONE PROTO NONE PROTO NONE %MACMGR-5-DETECT_STN_MOVE: Station Move threshold exceeded for Mac %s in vlan %d PORT_TEMP_MAJOR %CHMGR-1-PORT_TEMP_MAJOR: Major Alarm Interface %s shut due to high temperature PORT_TEMP_MINOR %CHMGR-1-PORT_TEMP_MINOR: Minor Alarm Interface %s temperature exceeds threshold PORT_TEMP_MAJOR_CLR %CHMGR-1-PORT_TEMP_MAJOR_CLR: Major Alarm cleared for Interface %s port tem
51 Storm Control The Dell Networking operating software storm control feature allows you to limit or suppress traffic during a traffic storm (Broadcast/Unknown Unicast Rate Limiting or Multicast on the C-Series and S-Series). Storm control is supported on Dell Networking OS. Important Points to Remember • Interface commands can only be applied on physical interfaces (virtual local area networks [VLANs] and link aggregation group [LAG] interfaces are not supported).
• Defaults For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 E-Series Only: Added the percentage decimal value option. 6.5.1.0 Introduced on the E-Series. Broadcast storm control is valid on Layer 2/Layer 3 interfaces only. Layer 2 broadcast traffic is treated as unknown-unicast traffic.
storm-control multicast (Configuration) Configure the packets per second (pps) of multicast traffic allowed into the C-Series and S-Series networks only. Syntax storm-control multicast packets_per_second in To disable storm-control for multicast traffic into the network, use the no storm-control multicast packets_per_second in command. Parameters packets_per_secon d in Enter the packets per second of multicast traffic allowed into the network. The range is from 0 to 33554368.
Command Modes INTERFACE (conf-if-interface-slot/port) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Usage Information Version Description 6.5.1.0 Introduced on the E-Series. Unknown Unicast Storm-Control is valid for Layer 2 and Layer 2/Layer 3 interfaces. storm-control unknown-unicast (Interface) Configure percentage of unknown-unicast traffic allowed on an interface (ingress only).
Version Description 7.5.1.0 Introduced on the C-Series. 7.4.1.0 E-Series Only: Added the percentage decimal value option. 6.5.1.0 Introduced on the E-Series.
52 Spanning Tree Protocol (STP) The commands in this chapter configure and monitor the IEEE 802.1d spanning tree protocol (STP) and are supported on the Dell Networking switch/routing platform. bridge-priority Set the bridge priority of the switch in an IEEE 802.1D spanning tree. Syntax bridge-priority {priority-value | primary | secondary} To return to the default value, use the no bridge-priority command. Parameters priority-value Enter a number as the bridge priority value.
bpdu-destination-mac-address Use the Provider Bridge Group address in Spanning Tree or GVRP PDUs. Syntax Parameters bpdu-destination-mac-address [stp | gvrp] provider-bridge-group xstp Force STP, RSTP, and MSTP to use the Provider Bridge Group address as the destination MAC address in its BPDUs. gvrp Forces GVRP to use the Provider Bridge GVRP Address as the destination MAC address in its PDUs. Defaults The destination MAC address for BPDUs is the Bridge Group Address.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced protocol spanning-tree — enters SPANNING TREE mode on the switch. disable Disable the spanning tree protocol globally on the switch. Syntax disable To enable Spanning Tree Protocol, use the no disable command. Defaults Enabled (that is, the spanning tree protocol is disabled.) Command Modes SPANNING TREE Command History This guide is platform-specific.
Defaults 15 seconds Command Modes SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. forward-delay — changes the wait time before STP transitions to the Forwarding state. max-age — changes the wait time before STP refreshes protocol configuration information.
protocol spanning-tree To enable and configure the spanning tree group, enter SPANNING TREE mode. Syntax protocol spanning-tree stp-id To disable the Spanning Tree group, use the no protocol spanning-tree stp-id command. Parameters stp-id Enter zero (0). Dell Networking OS supports one spanning tree group, group 0. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Example Field Description “Designated port...” Displays the designated port ID. Dell#show spann 0 Executing IEEE compatible Spanning Tree Protocol Bridge Identifier has priority 32768, Address 0001.e800.0a56 Configured hello time 2, max age 20, forward delay 15 We are the root of the spanning tree Current root has priority 32768 address 0001.e800.
Usage Information Example (Guard) The following describes the show spanning-tree 0 guard command shown in the example. Field Description Interface Name STP interface. Instance STP 0 instance. Sts Port state: root-inconsistent (INCON Root), forwarding (FWD), listening (LIS), blocking (BLK), or shut down (EDS Shut). Guard Type Type of STP guard configured (Root, Loop, or BPDU guard).
Enter the optional keyword shutdown-on-violation to hardware disable an interface when a BPDU is received and the port is disabled. priority priority Enter keyword priority then a number as the priority. The range is from zero (0) to 15. The default is 8. Defaults cost = depends on the interface type; priority = 8 Command Modes INTERFACE Command History This guide is platform-specific.
• If a BPDU is received from a remote device, BPDU guard places the port in an Err-Disabled Blocking state and no traffic is forwarded on the port. • If no BPDU is received from a remote device, loop guard places the port in a Loop-Inconsistent Blocking state and no traffic is forwarded on the port. To display the type of STP guard (Portfast BPDU, root, or loop guard) enabled on a port, enter the show spanning-tree 0 command.
53 System Time and Date The commands in this chapter configure time values on the system, either using the Dell Networking operating software, or the hardware, or using the network time protocol (NTP). With NTP, the switch can act only as a client to an NTP clock host. For more information, refer to the “Network Time Protocol” section of the Management chapter in the Dell Networking OS Configuration Guide.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
start-month Enter the name of one of the 12 months in English. start-time Enter the time in hours:minutes. For the hour variable, use the 24-hour format; example, 17:15 is 5:15 pm. end-week Enter the one of the following as the week that daylight saving ends: • week-number: enter a number from 1 to 4 as the number of the week to end daylight saving time. • first: enter the keyword first to end daylight saving time in the first week of the month.
clock timezone Configure a timezone for the switch. Syntax clock timezone timezone-name offset To delete a timezone configuration, use the no clock timezone command. Parameters timezone-name Enter the name of the timezone. You cannot use spaces. offset Enter one of the following: • a number from 1 to 23 as the number of hours in addition to universal time coordinated (UTC) for the timezone. • a minus sign (-) then a number from 1 to 23 as the number of hours. Defaults Not configured.
Parameters adjust Enter the keyword adjust to display information on NTP clock adjustments. all Enter the keyword all to display information on all NTP transactions. authentication Enter the keyword authentication to display information on NTP authentication transactions. events Enter the keyword events to display information on NTP events. loopfilter Enter the keyword loopfilter to display information on NTP local clock frequency.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. You also must configure an authentication key for NTP traffic using the ntp authentication-key command.
ntp disable Prevent an interface from receiving NTP packets. Syntax ntp disable To re-enable NTP on an interface, use the no ntp disable command. Defaults Disabled (that is, if you configure an NTP host, all interfaces receive NTP packets) Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added support for IPv6 multicast addresses. 8.3.7.0 Introduced on the S4810.
Parameters vrf vrf-name (Optional) Enter the keyword vrf and then the name of the VRF to configure a NTP time-serving host corresponding to that VRF. ipv4-address | ipv6address Enter an IPv4 address (A.B.C.D) or IPv6 address (X:X:X:X::X) of NTP server. hostname Enter the hostname of the server. key keyid (OPTIONAL) Enter the keyword key and a number as the NTP peer key. The range is from 1 to 4294967295.
ntp source Specify an interface’s IP address to be included in the NTP packets. Syntax ntp source interface To delete the configuration, use the no ntp source command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the S-Series. 7.5.1.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.2.1.0 Added options [0 | 7] for entering the authentication key. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. Example Dell#show clock 11:05:56.949 UTC Thu Oct 25 2001 Dell# Example (Detail) Dell#show clock detail 12:18:10.
Usage Information Version Description 6.1.1.0 Introduced on the E-Series. The following describes the show ntp associations command shown in the Example below. Field Description (none) One or more of the following symbols could be displayed: • * means synchronized to this peer. • # means almost synchronized to this peer. • + means the peer was selected for possible synchronization. • - means the peer is a candidate for selection. • ~ means the peer is statically configured.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Added support for VRF. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added IPv6 support. 7.6.1.
Field Description “Clock is...” States whether or not the switch clock is synchronized, which NTP stratum the system is assigned and the IP address of the NTP peer. “frequency is...” Displays the frequency (in ppm), stability (in ppm) and precision (in Hertz) of the clock in this system. “reference time is...” Displays the reference time stamp. “clock offset is...” Displays the system offset to the synchronized peer and the time delay on the path to the NTP root clock. “root dispersion is...
54 Tunneling Tunneling is supported on Dell Networking OS. ip unnumbered Configure a tunnel interface to operate without a unique IPv4 address and select the interface from which the tunnel borrows its address. Syntax ip unnumbered {interface-type slot/port[/subport]} To set the tunnel back to default logical address use the no ip unnumbered command. If the tunnel was previously operational, the tunnel interface is operationally down unless you also configure the tunnel IPv6 address.
ipv6 unnumbered Configure a tunnel interface to operate without a unique IPv6 address and select the interface from which the tunnel borrows its address. Syntax ipv6 unnumbered {interface-type interface-number} To set the tunnel back to default logical address use the no ipv6 unnumbered command. If the tunnel was previously operational, the tunnel interface is operationally down unless you also configure the tunnel IPv4 address. Parameters interface-type interface-number Defaults None.
mask (OPTIONAL) Enter a network mask in /prefix format (/x) or A.B.C.D to match a range of remote addresses. The default mask is /32 for IPv4 addresses and /128 for IPv6 addresses, which match only the specified address. Defaults If you do not configure tunnel allow remote , all traffic which is destined to tunnel source address is decapsulated. Command Modes INTERFACE TUNNEL Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.
To establish a logical tunnel to the particular destination address, use the destination address of the outer tunnel header. If you configure a tunnel interface or source address, the tunnel destination must be compatible. tunnel dscp Configure the method to set the DSCP in the outer tunnel header. C9000 Series Syntax tunnel dscp {mapped | value} To use the default tunnel mapping behavior, use the no tunnel dscp value command.
Parameters value Enter a value to set the IPv6 flow label value in the tunnel header. The range is from 0 to 1048575. The default value is 0. Defaults 0 (Mapped original packet flow-label value to tunnel header flow-label value) Command Modes INTERFACE TUNNEL (conf-if-tu) Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.3(0.0) Introduced on the S6000, S4810, S4820T, Z9000.
To disable the tunnel keepalive probes use the no tunnel keepalive command. Parameters ip-address ipv6 address Enter the IPv4 or IPv6 address of the peer to which the keepalive probes will be sent. interval seconds Enter the keyword interval then the interval time, in seconds, after which the restart process to keepalive probe packets. The range is from 5 to 255. The default is 5. count (OPTIONAL) Enter the keyword count to count packets processed by the filter. The range is from 3 to 10.
Parameters ipip Enable tunnel in RFC 2003 mode and encapsulate IPv4 and/or IPv6 datagrams inside an IPv4 tunnel. ipv6 Enable tunnel in RFC 2473 mode and encapsulate IPv4 and/or IPv6 datagrams inside an IPv6 tunnel. ipv6ip Enable tunnel in RFC 4213 mode and encapsulate IPv6 datagrams inside an IPv4 tunnel. decapsulate-any (Optional) Enable tunnel in multipoint receive-only mode. Defaults There is no default tunnel mode.
• anylocal For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Enter the anylocal command to allow the multipoint receive-only tunnel to decapsulate tunnel packets destined to any local ip address. Defaults none Command Modes INTERFACE TUNNEL (conf-if-tu) Command History Usage Information 1360 Tunneling Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.4(0.0) Added the tunnel source anylocal command. 9.3(0.
55 VLAN Stacking With the virtual local area network (VLAN)-stacking feature (also called stackable VLANs and QinQ), you can “stack” VLANs into one tunnel and switch them through the network transparently. The Dell Networking operating software supports this feature on Dell Networking OS. For more information about basic VLAN commands, refer to the Virtual LAN (VLAN) Commands section in the Layer 2 chapter.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the C-Series and S-Series. dei honor Honor the incoming DEI value by mapping it to an Dell Networking OS drop precedence. Enter the command once for 0 and once for 1. Syntax dei honor {0 | 1} {green | red | yellow} Parameters 0|1 Enter the bit value you want to map to a color.
dei mark Set the DEI value on egress according to the color currently assigned to the packet. S6000–ON Syntax Parameters dei mark {green | yellow} {0 | 1} 0|1 Enter the bit value you want to map to a color. green | red | yellow Choose a color: • Green: High priority packets that are the least preferred to be dropped. • Yellow: Lower priority packets that are treated as best-effort. Defaults All the packets on egress are marked with DEI 0.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Defaults Not configured. Command Modes CONF-IF-VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.
Usage Information WARNING: The following message displays to confirm the command: All non-default configurations on the related member ports ports () will be removed. Do you want to continue (y/n)? If you enter “y”, all non-default configurations on any member ports of the current stack group is removed when the unit is rebooted. vlan-stack access Specify a Layer 2 port or port channel as an access port to the stackable VLAN network.
To disable the Stackable VLAN feature on a VLAN, use the no vlan-stack compatible command. Defaults Not configured. Command Modes CONF-IF-VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
vlan-stack dot1p-mapping Map C-Tag dot1p values to a S-Tag dot1p value. You can separate the C-Tag values by commas and dashed ranges are permitted. Dynamic mode CoS overrides any Layer 2 QoS configuration in case of conflicts. Syntax Parameters vlan-stack dot1p-mapping c-tag-dot1p values sp-tag-dot1p value c-tag-dot1p value Enter the keyword c-tag-dot1p then the customer dot1p value that is mapped to a service provider do1p value. The range is from 0 to 7.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. C-Series and S-Series accept both bytes of the 2-byte S-Tag TPID. 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series and S-Series.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. C-Series and S-Series accept both bytes of the 2-byte S-Tag TPID. 7.8.1.0 Functionality augmented for C-Series and S-Series to enable multi-purpose use of the port. 7.7.1.0 Functionality augmented for E-Series to enable multi-purpose use of the port. 7.6.1.
! interface Vlan 20 no ip address tagged TenGigabitEthernet 1/23/1 shutdown Dell(conf-if-vl-20)#do show vlan Codes: * - Default VLAN, G - GVRP VLANs Q: U - Untagged, T - Tagged x - Dot1x untagged, X - Dot1x tagged G - GVRP tagged, M - Vlan-stack NUM Status Description * 1 Inactive 20 Active 100 Active Dell(conf-if-vl-20)# Example 2 Q Ports T Te 1/23/1 M Te 1/23/1 Dell(config)#vlan-stack protocol-type 88A8 Dell(config)#interface TenGigabitethernet 3/10/1 Dell(conf-if-te-3/10/1)#no shutdown Dell(conf-if-te-
56 Virtual Routing and Forwarding (VRF) Virtual Routing and Forwarding (VRF) allows multiple instances of a routing table to co-exist on the same router at the same time. ip unknown-unicast Enable IPv4 catch-all route. Syntax ip unknown-unicast To remove the IPv4 catch-all route (0.0.0.0/0) from the LPM route forwarding table in hardware which gets added as a default configuration after the initialization of FIB Agent module, use the no ip unknownunicast command.
Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. All the default catch-all entries in the longest prefix match (LPM) table collect and transmit all unresolved IPv6 packets to the CPU, even if they are destined for unknown destinations. description Enables you to specify a descriptive name for a customer VRF.
management Use this keyword when you want to associate the interface to the management VRF. Defaults None (Interface is part of default VRF). Command Modes INTERFACE-CONFIG Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
ip http vrf Configures an HTTP client with a VRF that is used to connect to the HTTP server. S6000–ON Syntax ip http vrf {management | vrf-name} To undo the HTTP client configuration, use the ip http vrf command. Parameters management Enter the keyword management for configuring the management VRF that uses an HTTP client. vrf-name Enter the name of the VRF for configuring a nondefault that uses an HTTP client.
CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, S6000–ON, and Z9500. You can use the ip route-export tag command without specifying the route-map attribute to export all the routes corresponding to a source VRF. This action exposes source VRF's routes to various other VRFs, which then import these routes using the ip route-import tag command.
Command History Usage Information Version Description 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, S6000–ON, and Z9500. It is possible to configure multiple import conditions per VRF depending on the exporting VRF. The export-target and import-target support only the match protocol and match prefix-list options. Other options that are configured in the route-maps are ignored. Related Commands ip route-export – exports routes to another VRF.
Related Commands ipv6 route-import – imports IPv6 routes from another VRF. ipv6 route-import Imports IPv6 routes that are leaked by another VRF using the tag specified by that VRF during export of these routes. Syntax Parameters ipv6 route-import tag [route-map-name] route-import Enter the keyword route-import to import IPv6 routes into the VRF. tag Enter a tag (ASN number) to specify an import route target for importing routes from another VRF.
connected Enter the keyword connected to leak or share connected routes corresponding to the VRF. static Enter the keyword static to leak or share static routes corresponding to the VRF. Defaults N/A Command Modes ROUTE MAP MODE Command History Usage Information Version Description 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, S6000–ON, and Z9500. You can specify the matching criteria only after defining a route-map.
interface management Associates a management port with a management VRF. Syntax interface management To delete the association between a management port and a management VRF, use the no interface management command. Defaults None. Command Modes VRF MODE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OSCommand Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON and Z9500. 9.4(0.0) Introduced on the S–Series.
management 64 FTOS#show ip vrf test1 VRF-Name VRF-ID Interfaces test1 1 Te 1/29/4,1/30/1-1/31/3 show run vrf Displays configuration information corresponding to all the VRFs in the system. Syntax Parameters Command Modes Command History show run vrf vrf-name vrf vrf-name • EXEC • EXEC Privilege Enter the keyword vrf and then the name of the VRF.. This guide is platform-specific.
57 VLT Proxy Gateway The Virtual link trucking (VLT) proxy gateway feature allows a VLT domain to locally terminate and route L3 packets that are destined to a Layer 3 (L3) end point in another VLT domain. Enable the VLT proxy gateway using the link layer discover protocol (LLDP) method or the static configuration. For more information, refer to Dell Networking OS Command Line Reference Guide. proxy-gateway lldp Enables the proxy-gateway feature using LLDP protocol.
Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, Z9000. Usage Information When proxy-gateway static configuration is added, the setting is saved in the Layer 2 module. When you remove the static proxy gateway configuration, each proxy-gateway static mac configured is deleted from the Layer 2 module.
peer-domain-link port-channel exclude-vlan Configure the VLT port channel, which is connected to remote VLT domain for Proxy Gateway and configure the VLANs that needs to be excluded from VLT Proxy Gateway. S6000–ON Syntax [no] peer-domain-link port-channel interface-identifier exclude-vlan vlanrange Parameters port-channel Configure the proxy-gateway interface port-channel. Port channel range is from 1 to 128. vlan-range Enter the VLAN IDs in which proxy gateway is not needed.
Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Removed the default value on the S-Series and Z-Series. 9.4(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL Switch. Usage Information When a VLT peer goes down, the local VLT node must stop sending its peer’s MAC address. If this timeout is configured, the local VLT node will send its peer's MAC address, till the timer expires. By default this timer value is infinity.
static Command Modes Display details about the static VLT proxy gateway configuration EXEC EXEC Privilege Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000.
58 Virtual Link Trunking (VLT) Virtual link trunking (VLT) allows physical links between two chassis to appear as a single virtual link to the network core. VLT eliminates the requirement for Spanning Tree protocols by allowing link aggregation group (LAG) terminations on two separate distribution or core switches, and by supporting a loop-free topology.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.2(0.2) Added support for IPv6. 9.0.2.
Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. Example VLT ARP Statistics ---------------ARP Tunnel Pkts sent:0 ARP Tunnel Pkts Rcvd:0 ARP-sync Pkts Sent:0 ARP-sync Pkts Rcvd:0 ARP Reg Request sent:19 ARP Reg Request rcvd:10 Related Commands show vlt statistics — displays statistics on VLT operations.
Related Commands • after a VLT device is reloaded. • if the Peer VLT device was up at the time the VLTi link failed to the time when it was restored. show vlt statistics — displays statistics on VLT operations. delay-restore abort-threshold Increase the Boot Up timer to some value (>60 seconds). Syntax delay-restore abort-threshold To remove use the no delay-restore abort-threshold command. Defaults 60 seconds Command Modes VLT DOMAIN Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Added port-channel parameter on the S4810. 8.3.8.0 Introduced on the S4810.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. 9.0.2.0 Introduced on the S6000. peer-link port-channel Configure the specified port channel as the chassis interconnect trunk between VLT peers in the domain.
peer-routing Enable L3 VLT peer-routing. This command is applicable for both IPV6/ IPV4. Syntax peer-routing To disable L3 VLT peer-routing, use the no peer-routing command. Defaults Disabled. Command Modes VLT DOMAIN (conf-vlt-domain) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Version Description 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. 9.0.2.0 Introduced on the S6000. When the timer expires, the software checks to see if the VLT peer is now available. If the VLT peer is not available, peer-routing is disabled on that peer. primary-priority Assign the priority for master election among VLT peers.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. Dell_VLTpeer1# show vlt backup-link VLT Backup Link ----------------Destination: Peer HeartBeat status: HeartBeat Timer Interval: HeartBeat Timeout: UDP Port: HeartBeat Messages Sent: HeartBeat Messages Received: 10.11.200.
Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. Usage Information If you do not add a parameter such as arp or mac, the output displays all of the counters.
Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.
(*, 225.1.1.2) Dell# VLAN 15 te 1/5/1 show vlt mismatch Display mismatches in VLT parameters. Syntax show vlt mismatch Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.
PB for stp Enabled Disabled Vlan-type-config ---------------Codes:: P - Primary, C - Community, I - Isolated, N - Normal vlan, M Vlan-stack Vlan-ID ------- Local ----- 100 Peer ---- N M Port-type-config ---------------Codes:: p - PVLAN Promiscuous port, h - PVLAN Host port, t - PVLAN Trunk port, mt - Vlan-stack trunk port, mu - Vlan-stack access port, n Normal port Vlt Lag ------128 Local ----mt Peer ---mu Vlan-stack protocol-type -----------------------Local ----0x4100 Peer ---0x8100 VLT-VLAN
Example Version Description 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810.
Related Commands Example Version Description 9.2(0.2) Added parameters multicast and ndp 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Added support in the output for ARP, MAC, and IGMP snooping. 8.3.8.0 Introduced on the S4810. clear vlt statistics — clears the statistics on VLT operations. NOTE: The following example shows the statistics for all of the VLT parameters.
NDP NA VLT Tunnel Pkts Rcvd:46 NDP NA Non-VLT Tunnel Pkts sent:0 NDP NA Non-VLT Tunnel Pkts Rcvd:0 Ndp-sync Pkts Sent:144 Ndp-sync Pkts Rcvd:105 Ndp Reg Request sent:25 Ndp Reg Request rcvd:24 show vlt statistics igmp-snoop Displays the informational packets and IGMP control PDUs that are exchanged between VLT peer nodes. Syntax show vlt statistics igmp-snoop Default Not configured. Command Modes EXEC Command History This guide is platform-specific.
Parameters 0|1 Configure the default unit ID of a VLT peer switch. Enter 0 for the first peer or enter 1 for the second peer. Defaults Automatically assigned based on the MAC address of each VLT peer. The peer with the lower MAC address is assigned unit 0; the peer with the higher MAC address is assigned unit 1. Command Modes VLT DOMAIN Command History This guide is platform-specific.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.1) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. Usage Information The VLT domain ID must be the same between the two VLT devices.
59 Virtual Extensible LAN (VXLAN) Virtual Extensible LAN (VXLAN) is supported on Dell Networking OS. feature vxlan Enable VXLAN configuration globally on the platform. Syntax feature vxlan To disable the VXLAN, use the no feature vxlan command. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version Description 9.7(0.
fail-mode Configures failure-mode on the platform. Syntax fail-mode secure To disable the fail-mode secure, use the no fail-mode securecommand. Parameters secure Enter the keyword secure to delete all its database and hardware flows/ resources, when the VTEP loses connectivity with the controller. Defaults non secure Command Modes VXLAN INSTANCE Command History This guide is platform-specific.
Related Commands feature vxlan — Enable VXLAN configuration globally on the platform. vxlan-instance (VAP) To configure a VXLAN-Access Port (VAP) in to VXLAN-instance Syntax vxlan-instance instance ID To unconfigure VAP, use the no vxlan-instance 1 command. Parameters instance ID Enter the VXLAN instance ID. The platform supports only the instance ID 1 in the initial release. Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific.
Usage Information The retry interval value caps at the value configured on the max-backoff. Related Commands vxlan-instance — Enable VXLAN Instance configuration on the platform. gateway-ip Configures gateway IP address on the platform. Syntax Parameters gateway-ip IP address IP address Enter the IP address of the gateway for the VXLAN instance. Defaults Disabled Command Modes VXLAN INSTANCE Command History This guide is platform-specific.
Command Modes VXLAN INSTANCE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S6000. vxlan-instance — Enable VXLAN instance configuration on the platform. show vxlan vxlan-instance Displays information related to Network Virtualization Overlay (NVO) Gateway.
show running-config vxlan Displays the VXLAN configuration information from running configuration. Syntax Command Modes Command History show running-config vxlan • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S6000.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S6000. Example Dell# show vxlan vxlan-instance <1> unicast-mac-remote Total Local Mac Count: 1 VNI MAC TUNNEL 4656 00:00:01:00:00:01 36.1.1.1 Related Commands vxlan-instance- Enable VXLAN Instance configuration on the platform.
4656 4656 Related Commands 00:00:02:00:03:03 00:00:02:00:03:04 Te 1/17/1 Te 1/17/1 0 0 vxlan-instance- Enable VXLAN Instance configuration on the platform. show vxlan vxlan-instance statistics interface Displays the port VLAN statistics information related to Network Virtualization Overlay (NVO) Gateway. Syntax Parameters Defaults Command Modes Command History Example show vxlan vxlan-instance instance ID statisitics interface interface instance ID Enter the VXLAN instance ID.
show vxlan vxlan-instance physical-locator Displays physical locators related to Network Virtualization Overlay (NVO) Gateway. Syntax show vxlan vxlan-instance instance ID physical—locator vtep-ip A.B.C.D Parameters instance ID Enter the VXLAN instance ID. The platform supports only the instance ID 1 in the initial release. A.B.C.D Enter the IP address of the VTEP. Defaults Disabled Command Modes VXLAN INSTANCE Command History This guide is platform-specific.
Example Version Description 9.4.(0.0) Introduced on the S6000. Dell#show vxlan vxlan-instance 1 logical-network Instance : 1 Total LN count : 1 Name bffc3be0-13e6-4745-9f6b-0bcbc5877f01 4656 VNID Dell#$n-instance 1 logical-network n 2a8d5d19-8845-4365-ad04-243f0b6df252 Name : 2a8d5d19-8845-4365-ad04-243f0b6df252 Description : Tunnel Key : 2 VFI : 28674 Unknown Multicast MAC Tunnels: 192.168.122.
Command History 1416 This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S6000.
60 Virtual Router Redundancy Protocol (VRRP) Virtual router redundancy protocol (VRRP) is supported by the Dell Networking operating system on Dell Networking OS. IPv4 VRRP Commands The following are IPv4 VRRP commands. advertise-interval Set the time interval between VRRP advertisements. Syntax advertise-interval {seconds | centisecs centisecs } To return to the default settings, use the no advertise-interval command. Parameters seconds Enter a number of seconds. The range is from 1 to 255.
Usage Information Dell Networking recommends keeping the default setting for this command. If you do change the time interval between VRRP advertisements on one router, change it on all routers. authentication-type Enable authentication of VRRP data exchanges. Syntax authentication-type simple [encryption-type] password To delete an authentication type and password, use the no authentication-type command. Parameters simple Enter the keyword simple to specify simple authentication.
Parameters vrrp-id (OPTIONAL) Enter the number of the VRRP group ID. The range is from 1 to 255. ipv6 (OPTIONAL) Enter the keyword ipv6 to clear counters from the IPv6 VRRP group. vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to clear counters that are maintained on the VRRP operations corresponding to that VRF. Command Modes EXEC Privilege Command History This guide is platform-specific.
all Enter the keyword all to enable debugging of all VRRP groups. bfd Enter the keyword bfd to enable debugging of VRRP BFD interactions. database Enter the keyword database to enable debugging of configuration changes. interface Enter the keyword interface to enable debugging of interface state changes.. ipv6 Enter the keyword ipv6 to enable debugging for IPv6. packets Enter the keyword packets to enable debugging of VRRP control packets.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. disable Disable a VRRP group. Syntax disable To re-enable a disabled VRRP group, use the no disable command. Command Modes VRRP Command History This guide is platform-specific.
To return to the default value, use the no hold-time command. Parameters seconds Enter the number of seconds. The range is from 0 to 65535. The default is zero (0) seconds. centisecs centisecs Enter the keyword centisecs then the number of centisecs in units of 25 centisecs . The range is from 0 to 65525 in units of 25 centisecs. Defaults zero (0) seconds or or (0) centiseconds Command Modes VRRP Command History This guide is platform-specific.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. priority Specify a VRRP priority value for the VRRP group. The VRRP protocol uses this value during the MASTER election process.
If you set the priority command to 255 and the virtual-address is not equal to the interface’s primary IP address, an error message appears. show config View the non-default VRRP configuration. Syntax show config [verbose] Parameters verbose (OPTIONAL) Enter the keyword verbose to view all VRRP group configuration information, including defaults. Command Modes VRRP Command History This guide is platform-specific.
Command Modes Command History • For Port Channel interface types, enter the keywords port-channel then the number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a VLAN interface, enter the keyword vlan then the VLAN ID. The VLAN ID range is from 1 to 4094. brief (OPTIONAL) Enter the keyword brief to view a table of information on the VRRP groups.
Item Description • NA/IF (the interface is not available). • MASTER (the interface associated with the MASTER router). • BACKUP (the interface associated with the BACKUP router). Master addr Displays the IP address of the MASTER router. Virtual addr(s) Displays the virtual IP addresses of the VRRP routers associated with the interface.
Example Item Description Tracking states.. This line is displayed if the track command is configured on an interface. Below this line, the following information on the tracked interface is displayed: • Dn or Up states whether the interface is down or up. • the interface type slot/port information. Dell>show vrrp -----------------TenGigabitEthernet 1/1/3, VRID: 1, Net: 10.1.1.253 State: Master, Priority: 105, Master: 10.1.1.
priority-cost Defaults priority cost = 10 Command Modes VRRP Command History Usage Information (OPTIONAL) Enter a number as the amount to be subtracted from the priority value. The range is 1 to 254. The default is 10. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 7.6.1.0 Introduced on the S-Series (S50 only). 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
Usage Information Version Description 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced support for telnetting to the VRRP group IP address assigned using this command. 6.2.1.1 Introduced on the E-Series. The VRRP group only becomes active and sends VRRP packets when a virtual IP address is configured. When you delete the virtual address, the VRRP group stops sending VRRP packets. A system message appears after you enter or delete the virtual-address command.
Related Command vrrp delay reload — sets the delay time for VRRP initialization after a system reboot. vrrp delay reload Set the delay time for VRRP initialization after a system reboot. Syntax vrrp delay reload seconds Parameters seconds Enter the number of seconds for the delay. The range is from 0 to 900 (0 indicates no delay). Defaults 0 Command Modes INTERFACE Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Usage Information You can use the version both command to migrate from VRRPv2 to VRRPv3. When you set the VRRP protocol version to both, the switch sends only VRRPv3 advertisements but can receive either VRRPv2 or VRRPv3 packets. To migrate an IPv4 VRRP group from VRRPv2 to VRRPv3: 1. Set the switches with the lowest priority to “both”. 2. Set the switch with the highest priority to version to 3. 3. Set all the switches from both to version 3.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. 8.4.1.0 Introduced on E-Series ExaScale, C-Series, and S-Series.
Usage Information Version Description 8.3.10.0 Introduced on the S4810. 8.4.1.0 Introduced on E-Series ExaScale, C-Series, and S-Series. Support was added for IPv6 VRRP groups in non-default VRF instances. 8.3.2.0 Introduced on the E-Series TeraScale. If no options are specified, debug is active on all interfaces and all VRRP groups. show vrrp ipv6 View the IPv6 VRRP groups that are active. If no VRRP groups are active, the Dell Networking OS returns No Active VRRP group.
Line Beginning with Description GigabitEthernet... Displays the Interface, the VRRP group ID, and the network address. If the interface is no sending VRRP packets, 0.0.0.0 appears as the network address. VRF VRF instance to which the interface (on which the VRRP group is configured) belongs. State: master... Displays the interface’s state: • Na/If (not available). • master (MASTER virtual router). • backup (BACKUP virtual router). the interface’s priority and the IP address of the MASTER.
Virtual IP address: 1::255 fe80::255 vrrp-ipv6-group Assign an interface to a VRRP group. Syntax vrrp-ipv6-group vrid Parameters vrid Enter the virtual-router ID number of the VRRP group. The VRID range is from 1 to 255. Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.