Users Guide

Command Modes VXLAN INSTANCE
Command History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
Version Description
9.10(0.0) Introduced on the S6100–ON.
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0) Introduced on the S4048–ON.
9.7(0.0) Introduced on the S6000-ON.
9.4.(0.0) Introduced on the S6000.
Usage Information The retry interval value caps at the value configured on the max-backoff.
Related Commands vxlan-instance — Enable VXLAN Instance configuration on the platform.
remote-vtep-ip
Create a remote VTEP and associate it to specified VNIDs.
Syntax
remote—vtep—ip IP Address vni-profile profile name
To delete the remote VTEP, use the no remote—vtep—ip command.
Parameters
IP Address Enter the IP Address of the remote VTEP.
vni-profile Enter the keyword vni-profile followed by the profile name to which the remote
VTEP has to be associated.
Defaults None.
Command Modes VXLAN-INSTANCE
Command History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
Version Description
9.11(0.0) Introduced on the S4048–ON, S4048T-ON, S6000–ON, S6010–ON, S6100–ON, and
Z9100–ON.
Usage Information Use this command to associate a specific VNID to a remote VTEP. Provide a valid profile name while associating
to the remote VTEP.
NOTE: The remote VTEP IP Address cannot be any of the local IP Addresses configured in the switch.
Virtual Extensible LAN (VXLAN) 1645