Administrator Guide
• The display output is sorted by prefixes; intra-area ECMP routes are not displayed together.
• For Type 2 external routes, Type 1 cost is not displayed.
NOTE: Starting with Version 9.4(0.0), the loopback IP address advertised to the neighbor is not
displayed in the output because they are not accounted as inactive OSPF routes, whereas the
loopback IP address is displayed until Dell EMC Networking OS Version 9.3(0.0). Starting with
Version 9.4(0.0), the show ip ospf routes command displays the interface and area ID information
of connected networks in addition to the other settings, whereas these details are not displayed
until Dell EMC Networking OS Version 9.3(0.0). Starting with Version 9.4(0.0), the metric of E2
routes in the output is displayed as an external metric, whereas until Dell EMC Networking OS
Version 9.3(0.0), the number of hops to the ASBR for E2 routes are displayed in the output.
Example
DellEMC# show ip ospf 100 route
Prefix Cost Nexthop Interface Area Type
1.1.1.1 1 0.0.0.0 Lo 0 0 Intra-Area
3.3.3.3 2 13.0.0.3 Te 1/4/1 1 Intra-Area
13.0.0.0 1 0.0.0.0 Te 1/4/1 0 Intra-Area
150.150.150.0 2 13.0.0.3 Te 1/4/1 - External
172.30.1.0 2 13.0.0.3 Te 1/4/1 1 Intra-Area
DellEMC#
show ip ospf statistics
Display OSPF statistics.
Syntax
show ip ospf [process-id | vrf vrf-name] statistics global | [interface name
{neighbor router-id}]
Parameters
process-id
Enter the OSPF Process ID to show a specific process. If no Process ID is entered,
command applies only to the first OSPF process.
vrf
vrf-name
Enter the keyword vrf followed by the name of the VRF to display statistics
corresponding to the OSPF process that is tied to a specific VRF.
global Enter the keyword global to display the packet counts received on all running OSPF
interfaces and packet counts OSPF neighbors receive and transmit.
interface
name
(OPTIONAL) Enter the keyword interface then one of the following interface
keywords and slot/port or number information:
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then
the slot/port/subport information.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/
port information.
• For a port channel interface, enter the keywords port-channel then a number.
• For a VLAN interface, enter the keyword vlan then a number from 1 to 4094.
neighbor
router-id
(OPTIONAL) Enter the keyword neighbor then the neighbor’s router-id in dotted
decimal format (A.B.C.D.).
Defaults None
Command Modes
• EXEC
• EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
Open Shortest Path First (OSPFv2 and OSPFv3) 1063