Service Manual
Version Description
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
9.0.0.0 Introduced on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810. Added support for source-interface for link-local IPv6
addressing.
8.3.11.1 Introduced on the Z9000.
8.2.1.0 Introduced on the E-Series ExaScale (IPv6). Increased the number of VLANs on
ExaScale to 4094 (was 2094).
8.1.1.0 Introduced on the E-Series ExaScale (IPv4).
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series and added support for IPv6 address on the E-Series
only.
Usage Information
The VRF congured using this command has a higher precedence than a VRF congured using the ip
telent vrf vrf-name command. If you do not use the VRF attribute in this command, then TELENT
client uses the VRF congured using the
ip telnet vrf vrf-name command.
The source interface congured using this command has a higher precedence than the source interface
congured using the ip telent source-interface command. If you do not congure a source
interface using this command, then the TELNET client uses the source interface congured using the
ip
telent source-interface command.
In case there is a mismatch between the VRF telnet source interface and the telent VRF, then an error is
reported.
Example
Dell#telnet vrf vrf1 10.10.10.2
telnet-peer-stack-unit
Open a Telnet connection to the peer stack unit.
Syntax
telnet-peer-stack-unit
Defaults Not congured.
Command Modes
• EXEC
• EXEC Privilege
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.