Service Manual
Version Description
pre-6.2.1.1 Introduced on the E-Series.
Usage Information
Untagged interfaces can only belong to one VLAN.
In the Default VLAN, you cannot use the no untagged interface command. To remove an untagged
interface from all VLANs, including the Default VLAN, enter INTERFACE mode and use the no
switchport
command.
Related Commands
interface vlan — congures a VLAN.
tagged — species which interfaces in a VLAN are tagged.
Far-End Failure Detection (FEFD)
The Dell Networking operating software supports far-end failure detection (FEFD) on the Ethernet interfaces of the S6000–ON
platform.
The FEFD feature detects and reports far-end link failures.
• FEFD is not supported on the Management interface.
• During an RPM failover, FEFD is operationally disabled for approximately 8 to 10 seconds.
• By default, FEFD is disabled.
debug fefd
Enable debugging of FEFD.
Syntax
debug fefd {events | packets} [interface]
To disable debugging of FEFD, use the no debug fefd {events | packets} [interface]
command.
Parameters
events Enter the keyword events to enable debugging of FEFD state changes.
packets Enter the keyword packets to enable debugging of FEFD to view information on
packets sent and received.
interface (OPTIONAL) Enter the following keywords and slot/port[/subport] or number
information:
• For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port/subport information.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the
slot/port information.
Command Modes EXEC Privilege
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.