Users Guide
Example of Dell Networking Enterprise-specific SNMP Traps
envmon
 STACK_STATE: Stack unit %d is in Active State
 STACKUNITUP: Stack unit 0 is up
envmon
 CARD_SHUTDOWN: %sLine card %d down - %s
 CARD_DOWN: %sLine card %d down - %s
 LINECARDUP: %sLine card %d is up
 CARD_MISMATCH: Mismatch: line card %d is type %s - type %s required.
 RPM_STATE: RPM1 is in Active State
 RPM_STATE: RPM0 is in Standby State
 RPM_DOWN: RPM 0 down - hard reset
 RPM_DOWN: RPM 0 down - card removed
 HOT_FAILOVER: RPM Failover Completed
 SFM_DISCOVERY: Found SFM 1
 SFM_REMOVE: Removed SFM 1
 MAJOR_SFM: Major alarm: Switch fabric down
 MAJOR_SFM_CLR: Major alarm cleared: Switch fabric up
 MINOR_SFM: MInor alarm: No working standby SFM
 MINOR_SFM_CLR: Minor alarm cleared: Working standby SFM present
 TASK SUSPENDED: SUSPENDED - svce:%d - inst:%d - task:%s
 RPM0-P:CP %CHMGR-2-CARD_PARITY_ERR
 ABNORMAL_TASK_TERMINATION: CRASH - task:%s %s
 CPU_THRESHOLD: Cpu %s usage above threshold. Cpu5SecUsage (%d)
 CPU_THRESHOLD_CLR: Cpu %s usage drops below threshold. Cpu5SecUsage (%d)
 MEM_THRESHOLD: Memory %s usage above threshold. MemUsage (%d)
 MEM_THRESHOLD_CLR: Memory %s usage drops below threshold. MemUsage (%d)
 DETECT_STN_MOVE: Station Move threshold exceeded for Mac %s in vlan %d
 CAM-UTILIZATION: Enable SNMP envmon CAM utilization traps.
envmon supply
 PEM_PRBLM: Major alarm: problem with power entry module %s
 PEM_OK: Major alarm cleared: power entry module %s is good
 MAJOR_PS: Major alarm: insufficient power %s
 MAJOR_PS_CLR: major alarm cleared: sufficient power
 MINOR_PS: Minor alarm: power supply non-redundant
 MINOR_PS_CLR: Minor alarm cleared: power supply redundant
envmon temperature
 MINOR_TEMP: Minor alarm: chassis temperature
 MINOR_TEMP_CLR: Minor alarm cleared: chassis temperature normal (%s %d
 temperature is within threshold of %dC)
 MAJOR_TEMP: Major alarm: chassis temperature high (%s temperature reaches or
 exceeds threshold of %dC)
 MAJOR_TEMP_CLR: Major alarm cleared: chassis temperature lower (%s %d
 temperature is within threshold of %dC)
envmon fan
 FAN_TRAY_BAD: Major alarm: fantray %d is missing or down
 FAN_TRAY_OK: Major alarm cleared: fan tray %d present
 FAN_BAD: Minor alarm: some fans in fan tray %d are down
 FAN_OK: Minor alarm cleared: all fans in fan tray %d are good
vlt
 Enable VLT traps.
vrrp
 Enable VRRP state change traps
xstp
 %SPANMGR-5-STP_NEW_ROOT: New Spanning Tree Root, Bridge ID Priority 32768,
 Address 0001.e801.fc35.
 %SPANMGR-5-STP_TOPOLOGY_CHANGE: Bridge port TenGigabitEthernet 1/8/1 transitioned
 from Forwarding to Blocking state.
 %SPANMGR-5-MSTP_NEW_ROOT_BRIDGE: Elected root bridge for instance 0.
 %SPANMGR-5-MSTP_NEW_ROOT_PORT: MSTP root changed to port Te 1/8/1 for instance
 0. My Bridge ID: 40960:0001.e801.fc35 Old Root: 40960:0001.e801.fc35 New Root:
 32768:00d0.038a.2c01.
Simple Network Management Protocol (SNMP)
815