Users Guide
Version Description
9.10(0.0) Introduced on the S6100–ON.
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.1.1.0 Introduced on the E-Series.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
7.4.1.0 Modied for E-Series: Revised from 78 to 240 characters.
Usage Information
Important Points to Remember:
• To use special characters as a part of the description string, you must enclose the whole string in double 
quotes.
• Spaces between characters are not preserved after entering this command unless you enclose the entire 
description in quotation marks (“desc_text”).
•
Entering a text string after the description command overwrites any previous text string that you 
previously congured as the description.
• The shutdown and description commands are the only commands that you can congure on an interface 
that is a member of a port-channel.
• Use the show interfaces description command to display descriptions congured for each interface.
duplex (10/100 Interfaces)
Congure duplex mode on the Management Interface interfaces where the speed is set to 10/100.
Syntax
duplex {half | full}
To return to the default setting, use the no duplex command.
Parameters
half Enter the keyword half to set the physical interface to transmit only in one direction.
full Enter the keyword full to set the physical interface to transmit in both directions.
Defaults Not congured.
Command Modes INTERFACE
Interfaces 665