Line Description
Voltage Low Alarm 
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Bias Low Alarm 
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
TX Power Low 
Alarm threshold
Factory-dened setting. Value can dier between SFP and SFP+.
RX Power Low 
Alarm threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Temp High Warning 
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Voltage High 
Warning threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Bias High Warning 
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
TX Power High 
Warning threshold
Factory-dened setting. Value can dier between SFP and SFP+.
RX Power High 
Warning threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Temp Low Warning 
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Voltage Low 
Warning threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Bias Low Warning 
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
TX Power Low 
Warning threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Power Low Warning 
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Temperature Current temperature of the SFPs. If this temperature crosses Temp High alarm/warning 
thresholds, the temperature high alarm/warning ag is set to true.
Voltage Current voltage of the SFPs. If this voltage crosses voltage high alarm/warning 
thresholds, the voltage high alarm/warning ag is set to true.
Tx Bias Current Present transmission (Tx) bias current of the SFP. If this crosses bias high alarm/warning 
thresholds, the TX bias high alarm/warning ag is set to true. If it falls below the low 
alarm/warning thresholds, the TX bias low alarm/warning ag is set to true.
Tx Power Present Tx power of the SFP. If this crosses Tx power alarm/warning thresholds, the Tx 
power high alarm/warning ag is set to true. If it falls below the low alarm/warning 
thresholds, the Tx power low alarm/ warning ag is set to true.
Rx Power Present receiving (Rx) power of the SFP. This value is either average Rx power or OMA. 
This depends on the Rx Power measurement type displayed above. If this crosses Rx 
power alarm/warning thresholds, the Rx power high alarm/warning ag is set to true. If it 
falls below the low alarm/warning thresholds, the Rx power low alarm/warning ag is set 
to true.