Dell Command Line Reference Guide for the S6000– ON System 9.7(0.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 About this Guide............................................................................................................ 37 Objectives.........................................................................................................................................................................37 Audience...........................................................................................................................................................................
Control and Monitoring..................................................................................................78 banner exec......................................................................................................................................................................78 banner login......................................................................................................................................................................79 banner motd...............
show tech-support......................................................................................................................................................... 128 ssh-peer-stack-unit......................................................................................................................................................... 131 telnet..........................................................................................................................................................
resequence access-list..............................................................................................................................................168 seq............................................................................................................................................................................169 Extended IP ACL Commands...........................................................................................................................................
match origin.............................................................................................................................................................. 217 match route-type......................................................................................................................................................218 match tag..............................................................................................................................................................
deny icmp (for Extended IPv6 ACLs)............................................................................................................................. 267 deny (for IPv6 ACLs)..................................................................................................................................................... 268 7 Bidirectional Forwarding Detection (BFD)................................................................... 270 bfd all-neighbors..........................................
bgp default local-preference.................................................................................................................................... 299 bgp dmzlink-bw....................................................................................................................................................... 300 bgp enforce-first-as..................................................................................................................................................
neighbor shutdown.................................................................................................................................................. 340 neighbor soft-reconfiguration inbound...................................................................................................................... 341 neighbor timers........................................................................................................................................................
hardware forwarding-table mode............................................................................................................................. 396 show hardware forwarding-table mode.................................................................................................................... 396 11 Control Plane Policing (CoPP)....................................................................................398 control-plane-cpuqos.......................................................
show running-config dcb-buffer-threshold.....................................................................................................................438 dcb pfc-queues..............................................................................................................................................................440 dcb {ets | pfc} enable.....................................................................................................................................................
Commands to Configure Secure DHCP.......................................................................................................................... 474 arp inspection........................................................................................................................................................... 474 arp inspection-trust..................................................................................................................................................
17 FCoE Transit.............................................................................................................. 505 clear fip-snooping database interface vlan..................................................................................................................... 505 clear fip-snooping statistics........................................................................................................................................... 506 debug fip snooping...........................
21 Internet Group Management Protocol (IGMP)...........................................................542 IGMP Commands...........................................................................................................................................................542 clear ip igmp groups................................................................................................................................................. 542 debug ip igmp..................................................
mtu.......................................................................................................................................................................... 586 negotiation auto....................................................................................................................................................... 587 portmode hybrid...................................................................................................................................................
debug ip dhcp................................................................................................................................................................ 639 debug ip icmp.................................................................................................................................................................640 debug ip packet.............................................................................................................................................
show cam-ipv6 extended-prefix.....................................................................................................................................694 ipv6 unicast-host-route..................................................................................................................................................695 ipv6 nd dns-server ........................................................................................................................................................
ipv6 router isis................................................................................................................................................................ 734 isis circuit-type............................................................................................................................................................... 735 isis csnp-interval....................................................................................................................................
28 Layer 2...................................................................................................................... 778 MAC Addressing Commands.......................................................................................................................................... 778 mac-address-table aging-time.................................................................................................................................. 778 mac-address-table static..........................
protocol lldp (Configuration)..................................................................................................................................... 815 protocol lldp (Interface)............................................................................................................................................ 816 show lldp neighbors...................................................................................................................................................
name..............................................................................................................................................................................850 protocol spanning-tree mstp........................................................................................................................................... 851 revision.......................................................................................................................................................
delay........................................................................................................................................................................ 884 description............................................................................................................................................................... 885 show running-config track......................................................................................................................................
ip ospf mtu-ignore....................................................................................................................................................924 ip ospf network........................................................................................................................................................ 924 ip ospf priority..........................................................................................................................................................
graceful-restart grace-period................................................................................................................................... 976 graceful-restart mode...............................................................................................................................................977 ipv6 ospf area...........................................................................................................................................................
ip pim sparse-mode................................................................................................................................................. 1018 ip pim sparse-mode sg-expiry-timer........................................................................................................................ 1019 ip pim ssm-range....................................................................................................................................................
strict-priority queue.................................................................................................................................................1061 Per-Port QoS Commands............................................................................................................................................. 1061 dot1p-priority...........................................................................................................................................................
rate shape.............................................................................................................................................................. 1098 service-pool wred...................................................................................................................................................1099 DSCP Color Map Commands.........................................................................................................................................
show rmon alarms..........................................................................................................................................................1137 show rmon events.........................................................................................................................................................1139 show rmon hc-alarm.................................................................................................................................................
password-attributes.................................................................................................................................................1178 service password-encryption...................................................................................................................................1179 show privilege.........................................................................................................................................................
ip ssh authentication-retries.................................................................................................................................... 1213 ip ssh connection-rate-limit..................................................................................................................................... 1213 ip ssh hostbased-authentication..............................................................................................................................1214 ip ssh key-size.
sflow ingress-enable..................................................................................................................................................... 1249 sflow extended-switch enable...................................................................................................................................... 1249 sflow max-header-size extended..................................................................................................................................
logging source-interface......................................................................................................................................... 1289 logging synchronous............................................................................................................................................... 1290 logging trap.............................................................................................................................................................
ntp server......................................................................................................................................................................1331 ntp source.................................................................................................................................................................... 1333 ntp trusted-key........................................................................................................................................
show ip vrf................................................................................................................................................................... 1366 show run vrf................................................................................................................................................................. 1367 57 VLT Proxy Gateway..................................................................................................1369 proxy-gateway lldp...........
show vxlan vxlan-instance unicast-mac-remote........................................................................................................... 1398 show vxlan vxlan-instance unicast-mac-local............................................................................................................... 1399 show vxlan vxlan-instance statistics interface..............................................................................................................
1 About this Guide This book provides information about the Dell Networking OS command line interface (CLI). This book also includes information about the protocols and features found in Dell Networking OS.
Information Icons This book uses the following information symbols: NOTE: The Note icon signals important operational information. CAUTION: The Caution icon signals information about situations that could result in equipment damage or loss of data. WARNING: The Warning icon signals information about hardware handling that could result in injury.
2 CLI Basics This chapter describes the command line interface (CLI) structure and command modes. The Dell Networking operating software commands are in a text-based interface that allows you to use the launch commands, change command modes, and configure interfaces and protocols. Accessing the Command Line When the system boots successfully, you are positioned on the command line in EXEC mode and not prompted to log in. You can access the commands through a serial console port or a Telnet session.
In this case, the user is “admin” on vty2. Obtaining Help As soon as you are in a command mode there are several ways to access help. To obtain a list of keywords at any command mode: Type a ? at the prompt or after a keyword. There must always be a space before the ?. To obtain a list of keywords with a brief functional description: Type help at the prompt. To obtain a list of available options: Type a keyword and then type a space and a ?.
• To navigate left or right in the Dell Networking OS command line, use the left and right Arrow keys. The shortcut key combinations at the Dell Networking OS command line are as follows: Key Combination Action CNTL-A Moves the cursor to the beginning of the command line. CNTL-B Moves the cursor back one character. CNTL-D Deletes the character at the cursor. CNTL-E Moves the cursor to the end of the line. CNTL-F Moves the cursor forward one character. CNTL-I Completes a keyword.
Using the Keyword no Command To disable, delete or return to default values, use the no form of the commands. For most commands, if you type the keyword no in front of the command, you disable that command or delete it from the running configuration. In this guide, the no form of the command is described in the Syntax portion of the command description.
Enabling Software Features on Devices Using a Command Option This capability to activate software applications or components on a device using a command is supported on the S4810, S4820T, and S6000, platforms. Starting with Release 9.4(0.0), you can enable or disable specific software functionalities or applications that need to run on a device by using a command attribute in the CLI interface.
show feature Verify the status of software applications, such as VRF, that are activated and running on a device. Syntax show feature Command Modes EXEC EXEC Privilege Command History Version 9.4(0.0) Introduced on the S4810, S4820T, and S6000. Usage Information You can activate VRF application on a device by using the feature vrf command in CONFIGURATION mode. The no feature vrf command is not supported on any of the platforms.
1. Verify that you are logged in to EXEC Privilege mode. 2. Enter the configure command. The prompt changes to include (conf). From this mode, you can enter INTERFACE mode by using the interface command. CONTROL-PLANE Mode To manage control-plane traffic, use CONTROL-PLANE mode. For more information, refer to Control Plane Policing (CoPP). To enter CONTROL-PLANE mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the control-plane-cpuqos command.
EXEC Mode When you initially log in to the switch, by default, you are logged in to EXEC mode. This mode allows you to view settings and enter EXEC Privilege mode, which is used to configure the device. When you are in EXEC mode, the > prompt is displayed following the host name prompt, which is “Dell” by default. You can change the host name prompt using the hostname command. NOTE: Each mode prompt is preceded by the host name. EXEC Privilege Mode The enable command accesses EXEC Privilege mode.
Prompt Interface Type Dell(conf-ifte-1/1)# Ten-Gigabit Ethernet interface then slot/port/subport information Dell(conf-iffo-1/1)# Forty-Gigabit Ethernet interface then slot/port information Dell(conf-iflo-0)# Loopback interface number Dell(conf-ifnu-0)# Null Interface then zero Dell(conf-ifpo-0)# Port-channel interface number Dell(conf-ifvl-0)# VLAN Interface then VLAN number (range 1–4094) Dell(conf-ifma-1/1)# Management Ethernet interface then slot/port information Dell(conf-iftu-0)# Tunn
2. Enter the protocol lldp command. The prompt changes to include (conf-lldp) or (conf-if-interface-lldp). LLDP MANAGEMENT INTERFACE Mode To enable and configure Link Layer Discovery Protocol (LLDP) on management interfaces, use LLDP MANAGEMENT INTERFACE mode. To enter LLDP MANAGEMENT INTERFACE mode: 1. Verify that you are logged in to LLDP mode. 2. Enter the management-interface command. The prompt changes to include (conf-lldp-mgmtIf).
To enter OPENFLOW INSTANCE mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the openflow of-instance command then the OpenFlow ID number of the instance you want to create or configure. The prompt changes to include (conf-of-instance of-id). You can return to the CONFIGURATION mode by entering the exit command. Per-VLAN SPANNING TREE (PVST+) Plus Mode To enable and configure the Per-VLAN Spanning Tree (PVST+) protocol, use PVST+ mode.
1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the protocol spanning-tree rstp command. The prompt changes to include (conf-rstp). You can return to CONFIGURATION mode by using the exit command. ROUTE-MAP Mode To configure a route map, use ROUTE-MAP mode. To enter ROUTE-MAP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Use the route-map map-name [permit | deny] [sequence-number] command. The prompt changes to include (config-route-map).
2. Enter the ipv6 router ospf {process-id} command. The prompt changes to include (conf-ipv6-router_ospf). You can return to CONFIGURATION mode by using the exit command. ROUTER RIP Mode To enable and configure Router Information Protocol (RIP), use ROUTER RIP mode. For more information, refer to Routing Information Protocol (RIP). To enter ROUTER RIP mode: 1. Verify that you are logged in to CONFIGURATION mode. 2. Enter the router rip command. The prompt changes to include (conf-router_rip).
3 File Management This chapter contains command line interface (CLI) commands needed to manage the configuration files as well as other file management commands. boot system Tell the system where to access the Dell Networking OS image used to boot the system. Syntax boot system {gateway ip address| stack-unit [{0-11 | 0-7]| all] [default | primary {system {A: | B: | bmp-boot} | tftp: | | secondary]} To return to the default boot sequence, use the no boot system command.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. To display these changes in the show bootvar command output, save the running configuration to the startup configuration (using the copy command) and reload system. The keyword bmp-boot is used only when the device boots up from BMP.
Version Description E-Series Original command. HTTP Copy via CLI Copy one file to another location. Dell Networking OS supports IPv4 and IPv6 addressing for FTP, TFTP, and SCP (in the hostip field). This feature is supported on platform. Syntax copy http://10.16.206.77/sample_file flash://sample_filecopy flash:// sample_file http://10.16.206.77/sample_file You can copy from the server to the switch and vice-versa. Parameters copy http: flash: Address or name of remote host []: 10.16.206.
compressed-config file-url Enter the keyword compressed-config to copy one file, after optimizing and reducing the size of the configuration file, to another location. Dell Networking OS supports IPv4 and IPv6 addressing for FTP, TFTP, and SCP (in the hostip field).
Usage Information Version Description 9.4(0.0) Added the compressed-config parameter. 9.0.2.0 Introduced on the S6000. 8.4.1.0 Added IPv6 addressing support for FTP, TFTP, and SCP. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added usbflash and rpm0usbflash commands on E-Series ExaScale. 7.6.1.0 Introduced on the S-Series and added the SSH port number to the SCP prompt sequence on all systems. 7.5.1.
internal Flash. The source is on a secure server running SSH, so you are prompted for the user datagram protocol (UDP) port of the SSH server on the remote host. Example Dell#copy running-config nfsmount:///filepath Destination file name [test.txt]: User name to login remote host: usrname Password to login remote host: Example Dell#copy scp: flash: Address or name of remote host []: 10.11.199.134 Port number of the server [22]: 99 Source file name []: test.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. Added support for NFS mount. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. Dell#dir Directory of flash: 1 drwx 8192 Jan 01 2 drwx 3072 Dec 15 3 drwx 4096 Jan 01 4 drwx 4096 Jan 01 5 d--4096 Jan 01 6 drwx 4096 Jan 01 7 drwx 4096 Nov 06 8 -rwx 4625 Nov 06 9 drwx 4096 May 31 flash: 2056916992 bytes total Example (NFS Mount) 1980 00:00:00 +00:00 . 2014 06:27:10 +00:00 ..
Usage Information Version Description 7.8.1.0 Introduced on the S-Series You must include the colon (:) when entering this command. After reformatting is complete, three empty directories are automatically created on flash: CRASH_LOG_DIR, TRACE_LOG_DIR and NVTRACE_LOG_DIR. CAUTION: This command deletes all files, including the startup configuration file. So, after executing this command, consider saving the running config as the startup config (use the write memory command or copy run start command).
mkdir Creates a directory on the NFS mounted file system. Syntax mkdir nfsmount://mount-point/usrname Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version 9.7(0.0) Introduced this command.
rmdir Removes a directory from the NFS mounted file system. Syntax rmdir nfsmount://mount-point/usrname Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version 9.7(0.0) Introduced this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS The following is a list of the Dell Networking OS version history for this command. Usage Information Version 9.7(0.0) Added support for NFS mount. Version 9.2(1.0) Introduced on the Z9500. Version 9.0(0.0) Added support for IPv6 for the file-url parameter. Version 8.3.19.0 Introduced on the S4820T. Version 8.3.11.1 Introduced on the Z9000.
Version Description Version 9.7(0.0) Introduced on the S6000-ON. Added support for NFS mount. Version 9.0.2.0 Introduced on the S6000. Version 8.3.19.0 Introduced on the S4820T. Version 8.3.11.1 Introduced on the Z9000. Version 8.3.7.0 Introduced on the S4810. Version 7.6.1.0 Introduced on S-Series Version 7.5.1.0 Introduced on C-Series E-Series Original command show boot system Displays information about boot images currently configured on the system.
Current system image information in the system: ============================================= Type Boot Type A B ---------------------------------------------------------------Stack-unit 1 FLASH BOOT 9-0(2-1) 9-0(2-0)[boot] Dell# show bootvar Display the variable settings for the boot parameters. Syntax show bootvar Command Modes EXEC Privilege Command History This guide is platform-specific.
show file-systems Display information about the file systems on the system. Syntax show file-systems Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Related Commands format flash (S-Series) – Erases all the existing files and reformats the filesystem in the internal flash memory on the S-Series. show os-version Display the release and software image version information of the image file specified. Syntax Parameters show os-version [file-url] file-url (OPTIONAL) Enter the following location keywords and information: • For a file on the internal flash, enter flash:// followed by the filename.
Parameters entity (OPTIONAL) To display that entity’s current (non-default) configuration, enter one of the following keywords: NOTE: If you did not configure anything that entity, nothing displays and the prompt returns.
logging for the current logging configuration mac for the current MAC ACL configuration mac-addresstable for the current MAC configuration managementeis for the current management EIS configuration managementroute for the current Management port forwarding configuration mld for the current MLD configuration monitor for the current Monitor configuration mroute for the current Mroutes configuration msdp for the current MSDP configuration ntp for the current NTP configuration ospf for the
tacacs+ for the current TACACS+ configuration tftp for the current TFTP configuration trace-group for the current trace-group configuration trace-list for the current trace-list configuration uplink-stategroup for the uplink state group configuration users for the current users configuration vlt for the current VLT configuration wred-profile for the current wred-profile configuration configured (OPTIONAL) Enter the keyword configuration to display line card interfaces with non-default confi
! Startup-config last updated at Thu Apr 18 10:18:40 2013 by admin ! boot system stack-unit 1 primary system: A: boot system stack-unit 1 secondary tftp://10.16.127.35/Dell-SI-9-0-2-0.bin boot system stack-unit 1 default system: A: boot system gateway 10.16.132.
! Last configuration change at Thu Apr 18 10:18:39 2013 by admin ! Startup-config last updated at Thu Apr 18 10:18:40 2013 by admin ! boot system stack-unit 0 primary system: A: boot system stack-unit 0 secondary tftp://10.16.127.35/Dell-SI-9-0-2-0.bin boot system stack-unit 0 default system: A: boot system gateway 10.16.132.254 ! redundancy auto-synchronize full redundancy disable-auto-reboot stack-unit ... Related Commands show running-config – displays the current (running) configuration.
Example (S-Series) Lines Beginning With Description System image... Image file name System Type: S4810, S4820T, Z9000, S6000 Control Processor:... Control processor information and amount of memory on processor 128K bytes... Amount and type of memory on system 1 Route Processor... Hardware configuration of the system, including the number and type of physical interfaces available Dell#show version Dell Real Time Operating System Software Dell Operating System Version: 1.
upgrade system Upgrade the system image. Syntax upgrade system {flash: | ftp: | scp: | tftp: | usbflash: | stack-unit {0-5 | all} {A: | B:} Parameters 0–5 Enter the keywords 0–5 to upgrade only the mentioned stack-unit. all Enter the keyword all to upgrade all the member units of the stack. ftp Enter the keyword ftp to follow it with the location of the source file in this form: //userid:password@hostip/filepath, or press Enter to launch a prompt sequence.
userid:password@hostip/filepath) stack-unit Sync image to the stack-unit tftp: Copy from remote file system, IPv4 or IPv6, (tftp:// hostip/filepath) usbflash: Copy from usbflash file system (usbflash://filepath) Dell# upgrade boot Upgrade the bootflash image or bootselector image.
Version 8.3.11.1 Introduced on the Z9000. Added support for the SSD on the Z9000 only. Version 8.3.7.0 Introduced on the S4810. Version 7.7.1.0 Added support for TFTP and SCP. Version 7.6.1.0 Introduced on the S-Series. Usage Information You must reload Dell Networking OS after executing this command.
Example Without Entering the Hash Value for Verification using SHA256 Dell# verify sha256 flash://FTOS-SE-9.5.0.0.bin SHA256 hash for FTOS-SE-9.5.0.0.bin: e6328c06faf814e6899ceead219afbf9360e986d692988023b749e6b2093e933 Entering the Hash Value for Verification using SHA256 Dell# verify sha256 flash://FTOS-SE-9.5.0.0.bin e6328c06faf814e6899ceead219afbf9360e986d692988023b749e6b2093e933 SHA256 hash VERIFIED for FTOS-SE-9.5.0.0.
4 Control and Monitoring This chapter contains the commands to configure and monitor the system, including Telnet, file transfer protocol (FTP), and trivial file transfer protocol (TFTP). NOTE: This command replaces the enable optic-info-update interval command to update information on temperature and power monitoring in the simple network management protocol (SNMP) management information base (MIB). banner exec Configure a message that is displayed when your enter EXEC mode.
Version Description E-Series Original Command Usage Information After entering the banner login command, type one or more spaces and a delineator character. Enter the banner text then the second delineator character. When the user is connected to the router, if a message of the day banner is configured, it displays first. If no message of the day banner is configured, the login banner and prompt appear. After the user has logged in, the banner EXEC (if configured) displays.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.2.1.0 Introduced the keyword keyboard-interactive.
banner motd Set a message of the day (MOTD) banner. Syntax banner motd c line c To delete a Message of the Day banner, enter no banner motd. Parameters c Enter a delineator character to specify the limits of the text banner. The delineator is a percent character (%). line Enter a text string for your MOTD banner the message with your delineator. The delineator is a percent character (%). Defaults No banner is configured.
cam-acl Allocate content addressable memory (CAM) for IPv4 and IPv6 ACLs.
Usage Information Version Description 8.3.1.0 Added the keywords ecfmacl, vman-qos, and vman-dual-qos. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series. For the new settings to take effect, save the new CAM settings to the startup-config (write-mem or copy run start) then reload the system. The total amount of space allowed is 16 FP Blocks. System flow requires three blocks and these blocks cannot be reallocated. The ipv4acl profile range is from 1 to 4.
Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. configure Enter CONFIGURATION mode from EXEC Privilege mode. Syntax configure [terminal] Parameters terminal (OPTIONAL) Enter the keyword terminal to specify that you are configuring from the terminal. Command Modes EXEC Privilege Command History This guide is platform-specific.
Parameters level (OPTIONAL) Enter a number for a privilege level of the Dell Networking OS. The range is from 0 to 15. The default is 1. Defaults 1 Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Usage Information Example Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. Users entering EXEC Privilege mode or any other configured privilege level can access configuration commands.
Usage Information Version Description 8.3.10.0 Replacement command for the S4810 only. Replaces the enable xfp-powerupdates command. To enable polling and to configure the polling frequency, use this command. end Return to EXEC Privilege mode from other command modes (for example, CONFIGURATION or ROUTER OSPF modes).
Related Commands exit — returns to the lower command mode. exec-timeout Set a time interval that the system waits for input on a line before disconnecting the session. Syntax exec-timeout minutes [seconds] To return to default settings, use the no exec-timeout command. Parameters minutes Enter the number of minutes of inactivity on the system before disconnecting the current session. The range is from 0 to 35791. The default is 10 minutes for the console line and 30 minutes for the VTY line.
Command Modes Command History • EXEC Privilege • CONFIGURATION • LINE, INTERFACE • TRACE-LIST • PROTOCOL GVRP • SPANNING TREE • MULTIPLE SPANNING TREE • MAC ACCESS LIST • ACCESS-LIST • AS-PATH ACL • COMMUNITY-LIST • PREFIX-LIST • ROUTER OSPF • ROUTER RIP • ROUTER ISIS • ROUTER BGP This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.
Usage Information Version Description E-Series Original command. The hostname is used in the prompt. ip ftp password Specify a password for outgoing FTP connections. Syntax ip ftp password [encryption-type] password To remove a password and return to the default setting, use the no ip ftp password [password] command.
Related Commands ip ftp username — sets the user name for the FTP sessions. ip ftp source-interface Specify an interface’s IP address as the source IP address for FTP connections. Syntax ip ftp source-interface interface To delete an interface, use the no ip ftp source-interface interface command.
ip tftp vrf Configures an TFTP client with a VRF that is used to connect to the TFTP server. Syntax ip tftp [vrf vrf-name] To undo the TFTP client configuration, use the no ip tftp [vrf vrf-name] command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to specify the VRF that is used by the TFTP client. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command.
ip telnet server enable Enable the Telnet server on the switch. Syntax ip telnet server enable To disable the Telnet server, use the no ip telnet server enable command. Defaults Enabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.4.(0.0) Introduced on the S-Series and Z9000.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.2.1.0 Increased number of VLANs on ExaScale to 4094 (was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series.
Related Commands ftp-server topdir — sets the directory to be used for incoming FTP connections. ftp-server username — sets a username and password for incoming FTP connections. line Enable and configure console and virtual terminal lines to the system. This command accesses LINE mode, where you can set the access conditions for the designated line. Syntax Parameters line {aux 0 |console 0 | vty number [end-number]} aux 0 Enter the keyword aux 0 to configure the auxiliary terminal connection.
motd-banner Enable a message of the day (MOTD) banner to appear when you log in to the system. Syntax motd-banner To disable the MOTD banner, use the no motd-banner command. Defaults Enabled on all lines. Command Modes LINE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
count Enter the number of echo packets to be sent. The default is 5. • number: from 1 to 2147483647 • continuous: transmit echo request continuously datagram size Enter the ICMP datagram size. The range is from 36 to 15360 bytes. The default is 100. timeout Enter the interval to wait for an echo reply before timing out. The range is from 0 to 3600 seconds. The default is 2 seconds. source Enter the IPv4 or IPv6 source ip address or the source interface.
Defaults • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Example (IPv4) Symbol Description ! Each exclamation point indicates receipt of a reply. . Each period indicates the network server timed out while waiting for a reply. U A destination unreachable error PDU was received. Q Source quench (destination too busy). M Could not fragment. ? Unknown packet type. & Packet lifetime exceeded. Dell#ping 172.31.1.255 Type Ctrl-C to abort. Sending 5, 100-byte ICMP Echos to 172.31.1.255, timeout is 2 seconds: Reply to request 1 from 172.31.1.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 9.1(0.0) Added ‘conditional’ parameter. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. If there is a change in the configuration, FTOS prompts you to save the new configuration. Or you can save your running configuration with the copy running-config command.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced on the E-Series. Messages can contain an unlimited number of lines; however, each line is limited to 255 characters. To move to the next line, use . To send the message use CTR-Z; to abort a message, use CTR-C. service timestamps To debug and log messages, add time stamps. This command adds either the uptime or the current time and date.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series Original command. If you do not specify parameters and enter service timestamps, it appears as service timestamps debug uptime in the running-configuration. To view the current options set for the service timestamps command, use the show runningconfig command.
Example Dell# show alarms -- Minor Alarms -Alarm Type Duration ---------------------------------------------RPM 0 PEM A failed or rmvd 7 hr, 37 min SFM 0 PEM A failed or rmvd 7 hr, 37 min SFM 1 PEM A failed or rmvd 7 hr, 37 min SFM 2 PEM A failed or rmvd 7 hr, 37 min SFM 3 PEM A failed or rmvd 7 hr, 37 min SFM 4 PEM A failed or rmvd 7 hr, 37 min SFM 5 PEM A failed or rmvd 7 hr, 37 min SFM 6 PEM A failed or rmvd 7 hr, 37 min SFM 7 PEM A failed or rmvd 7 hr, 36 min stack-unit 1 PEM A failed or rmvd 7 hr, 36
Version Description 8.2.1.0 Introduced. Usage Information Reload the system to reset the command-tree counters.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series 6.2.1.1 Introduced on the E-Series. Traffic statistics are sorted on a per-interface basis; the interface receiving the most traffic is displayed first.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series E-Series Original command. Example show environment View S-Series and Z-Series system component status (for example, temperature or voltage).
Version Description 8.3.11.1 Introduced on the Z9000. 7.8.1.0 The output of the show environment fan command for the S-Series is changed to display fan speeds instead of showing the fan status as up or down. Usage Information The following example shows the output of the show environment command.
show inventory Display the S-Series or Z-Series switch type, components (including media), and Dell Networking Operating System (OS), including hardware identification numbers and configured protocols.
0 0 0 0 0 0 0 0 0 0 0 Related Commands 0 1 2 3 4 5 6 7 8 9 10 QSFP QSFP QSFP QSFP QSFP QSFP QSFP QSFP QSFP QSFP QSFP 40GBASE-CR4-1M 40GBASE-CR4-1M 40GBASE-CR4-1M 40GBASE-CR4-1M 40GBASE-CR4-1M 40GBASE-CR4-1M 40GBASE-CR4-1M 40GBASE-CR4-1M 40GBASE-CR4-1M 40GBASE-CR4-1M 40GBASE-CR4-1M APF11200012UQQ APF11200012UQQ APF11200012UQQ APF11200012UQQ APF11200012UR1 APF11200012UR1 APF11200012UR1 APF11200012UR1 APF12300017GEY APF12300017GEY APF12300017GEY Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes • show interfa
Total(b) Used(b) Free(b) Lowest(b) Largest(b) 268435456 4010354 264425102 264375410 264425102 Example (S4820T) Dell#show memory stack 0 Statistics On Unit 0 Processor =========================== Total(b) Used(b) Free(b) Lowest(b) Largest(b) 2147483648 4322398 2143161250 2142548382 2143161250 Dell# show processes cpu Display CPU usage information based on processes running.
Example Version Description 7.6.1.0 Introduced on the S-Series. Dell#show processes cpu ? management-unit Management Unit stack-unit Unit Number summary Summary of CPU utilization | Pipe through a command Dell#show processes cpu summary CPU utilization 5Sec 1Min 5Min ------------------------------------------UNIT0 3% 3% 1% Dell#show processes cpu stack-unit 0 CPUID 5sec 1min 5min -------------------------------------------------CORE 0 13.17 11.53 0.00 CORE 2 9.38 12.16 0.00 Overall 11.28 11.84 0.
PID Runtime(ms) Invoked uSecs TTY Process Process: system PID: 0 CPU usage: 5sec 5min - 12.94% CoreID: 3 Process: sysdlp PID: 428 CPU usage: 5sec 5min - 3.40% CoreID: 0 Process: sysd PID: 410 CPU usage: 5sec 5min - 2.50% CoreID: 2 TID Runtime(ms) Invoked uSecs 5Min TTY Thread 56 20 2 10000 0.00% 0 usm 55 10 1 10000 0.00% 0 DHCLIENT 54 0 0 0 0.00% 0 cms 53 60 6 10000 0.00% 0 portmirr 52 0 0 0 0.00% 0 cfgDataSync 51 0 0 0 0.00% 0 sysCompMgr 50 50 5 10000 0.00% 0 statMgr 49 1010 101 10000 0.
0 ovsdbsvr 0x000000a9 200 0 arpm 0x00000253 100 0 otm 0x00000206 140 0 tnlmgr 0x00000012 1290 0 mount_mfs 0x0000024d 400 0 xstp Related Commands 20 10000 0.20% 0.03% 0.06% 10 10000 0.20% 0.02% 0.02% 14 10000 0.20% 0.02% 0.03% 129 10000 0.00% 0.10% 0.12% 40 10000 0.00% 0.08% 0.14% show hardware layer2 acl — displays Layer 2 ACL data for the selected stack member and stack member port-pipe.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series and E-Series.
show processes memory Display memory usage information based on processes running in the S-Series or Z-Series system. Syntax Parameters Command Modes Command History show processes memory {management-unit | stack unit {unit-id | all | summary}} management-unit Enter the keyword management-unit for CPU memory usage of the stack management unit. stack unit unit id Enter the keyword stack unit then a stack unit ID of the member unit for which to display memory usage on the forwarding processor.
show processes memory output Description Process Process Name ResSize Actual resident size of the process in memory Size Process test, stack, and data size Allocs Total dynamic memory allocated Frees Total dynamic memory freed Max Maximum dynamic memory allocated Current Current dynamic memory in use Field The output for the show process memory command displays the memory usage statistics running on CP part (sysd) of the system.
273 acl 5005312 512000 239564 149076 123616 272 topoDPC 117927936 0 0 0 0 271 bcmNHOP 117927936 0 0 0 0 270 bcmDISC 117927936 0 0 0 0 269 bcmATP-RX 117927936 0 0 0 0 268 bcmATP-TX 117927936 0 0 0 0 267 bcmSTACK 117927936 0 0 0 0 266 bcmRX 117927936 0 0 0 0 265 bcmLINK.0 117927936 0 0 0 0 !----------- output truncated --------------! 90488 0 0 0 0 0 0 0 0 show software ifm Display interface management (IFM) data.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 7.6.1.0 Introduced for the C-Series and S-Series.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. Version 9.4(0.0) Added support for the disabled-ports parameter . Version 9.0.2.0 Introduced on the S6000. Version 9.0.0.0 Introduced on the Z9000. Version 8.3.19.0 Introduced on the S4820T. Version 8.3.11.4 The brief parameter no longer displays the current Reload mode. To display Reload mode, use the show reload-type command.
Example (S6000) Dell#show system Stack MAC : 90:b1:1c:f4:9b:79 Reload-Type : normal-reload [Next boot : normal-reload] -- Unit 0 -Unit Type : Management Unit Status : online Next Boot : online Required Type : S6000 - 32-port TE/FG (SI) Current Type : S6000 - 32-port TE/FG (SI) Master priority : 0 Hardware Rev : 4.
Up Time : 21 min, 8 sec Dell Networking OS Version : 9-4(0-168) Jumbo Capable : yes POE Capable : no FIPS Mode : disabled Boot Flash : 3.1.1.2 Boot Selector : 3.1.0.
Auto Reboot Burned In MAC No Of MACs : disabled : 00:00:00:00:00:00 : 3 -- Power Supplies -Unit Bay Status Type FanStatus FanSpeed(rpm) --------------------------------------------------------------------------1 1 up AC up 18528 1 2 absent absent 0 -- Fan Status -Unit Bay TrayStatus Fan1 Speed Fan2 Speed -----------------------------------------------------------------------------------1 1 up up 19275 up 19275 1 2 absent 1 3 up up 19275 up 18904 Speed in RPM Related Commands • show version – displays t
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced save to the file options. 7.6.1.0 Introduced on the S-Series. Without the page or stack-unit option, the command output is continuous. To interrupt the command output, use Ctrl-z. The save option works with other filtering commands. This allows you to save specific information of a show command.
Dell#show tech-support stack-unit 1 | save ? flash: Save to local file system (flash://filename (max 20 chars) ) Dell#show tech-support stack-unit 1 | save flash://LauraSave Start saving show command report ....... Dell# Dell#dir Directory of flash: 1 drw- 16384 Jan 01 1980 00:00:00 +00:00 . 2 drwx 1536 Jul 13 1996 02:38:06 +00:00 ..
hardware watchdog stack-unit 5 ! Related Commands ssh-peer-stack-unit Open an SSH connection to the peer stack-unit. Syntax Parameters Defaults Command Modes Command History ssh-peer-stack-unit [-l username] -l username (OPTIONAL) Enter the keyword -l then your user name. The default is the user name associated with the terminal. Not configured. • EXEC • EXEC Privilege This guide is platform-specific.
ipv6-address prefixlength Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros. Defaults vrf instance (Optional) Enter the keyword vrf then the VRF instance name. source-interface (OPTIONAL) Enter the keywords /source-interface then the interface information to include the source interface.
Usage Information The VRF configured using this command has a higher precedence than a VRF configured using the ip telent vrf vrf-name command. If you do not use the VRF attribute in this command, then TELENT client uses the VRF configured using the ip telnet vrf vrf-name command. The source interface configured using this command has a higher precedence than the source interface configured using the ip telent source-interface command.
Parameters Defaults screen-length Enter a number of lines. Entering zero causes the terminal to display without pausing. The range is from 0 to 512. 24 lines Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Command Modes Command History • UDP port = 33434 • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
Example (IPv6) Dell#traceroute 100::1 Type Ctrl-C to abort. ----------------------------------------------Tracing the route to 100::1, 64 hops max, 60 byte packets ----------------------------------------------Hops Hostname Probe1 Probe2 Probe3 1 100::1 000.000 ms 000.000 ms 000.000 ms FTOS#traceroute 3ffe:501:ffff:100:201:e8ff:fe00:4c8b Type Ctrl-C to abort.
virtual-ip Configure a virtual IP address for the active management interface. You can configure virtual addresses both for IPv4 and IPv6 independently. Syntax virtual-ip {ipv4-address | ipv6-address} To return to the default, use the no virtual-ip {ipv4-address | ipv6-address} command. Parameters ipv4-address Enter the IP address of the active management interface in a dotted decimal format (A.B.C.D.). ipv6-address Enter an IPv6 address of the active management interface, in the x:x:x:x::x format.
Parameters memory Enter the keyword memory to copy the current running configuration to the startup configuration file. This command is similar to the copy runningconfig startup-config command. compressed Enter the keyword compressed to write the operating configuration to the startup-config file in the compressed mode. terminal Enter the keyword terminal to copy the current running configuration to the terminal. This command is similar to the show running-config command.
5 802.1X An authentication server must authenticate a client connected to an 802.1X switch port. Until the authentication, only extensible authentication protocol over LAN (EAPOL) traffic is allowed through the port to which a client is connected. After authentication is successful, normal traffic passes through the port. The Dell Networking operating software supports remote authentication dial-in service (RADIUS) and active directory environments using 802.1X Port Authentication.
interface interface Restricts the debugging information to an interface. Defaults Disabled Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Introduced on the C-Series and S-Series. If the host responds to 802.1X with an incorrect login/password, the login fails. The switch attempts to authenticate again until the maximum attempts configured is reached. If the authentication fails after all allowed attempts, the interface moves to the authentication failed VLAN.
dot1x auth-type mab-only To authenticate a device with MAC authentication bypass (MAB), only use the host MAC address. Syntax dot1x auth-type mab-only Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
dot1x guest-vlan Configure a guest VLAN for limited access users or for devices that are not 802.1X capable. Syntax dot1x guest-vlan vlan-id To disable the guest VLAN, use the no dot1x guest-vlan vlan-id command. Parameters vlan-id Enter the VLAN Identifier. The range is from 1 to 4094. Defaults Not configured. Command Modes CONFIGURATION (conf-if-interface-slot/port) Command History This guide is platform-specific.
dot1x host-mode Enable single-host or multi-host authentication. Syntax Parameters dot1x host-mode {single-host | multi-host | multi-auth} single-host Enable single-host authentication. multi-host Enable multi-host authentication. multi-auth Enable multi-supplicant authentication. Defaults single-host Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
Version Description 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x max-supplicants Restrict the number of supplicants that can be authenticated and permitted to access the network through the port. This configuration is only takes effect in Multi-auth mode. Syntax Parameters dot1x max-supplicants number number Enter the number of supplicants that can be authenticated on a single port in Multi-auth mode.
force-unauthorized Enter the keywords force-unauthorized to forcibly de-authorize a port. Defaults none Command Modes Auto Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.
Version Description 8.3.12.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x reauthentication Enable periodic reauthentication of the client. Syntax dot1x reauthentication [interval seconds] To disable periodic reauthentication, use the no dot1x reauthentication command. Parameters interval seconds (Optional) Enter the keyword interval then the interval time, in seconds, after which reauthentication is initiated.
Parameters number Enter the permitted number of re-authentications. The range is from 1 to 10. The default is 2. Defaults 2 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. When you configure the dot1x server-timeout value, take into account the communication medium used to communicate with an authentication server and the number of RADIUS servers configured.
Version Description 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x tx-period Configure the intervals at which EAPOL PDUs the Authenticator PAE transmits. Syntax dot1x tx-period seconds To return to the default, use the no dot1x tx-period command. Parameters seconds Enter the interval time, in seconds, that EAPOL PDUs are transmitted. The range is from 1 to 65535. The default is 30.
mac-address Defaults Command Modes Command History • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. (Optional) MAC address of an 802.1X-authenticated supplicant. none • EXEC • EXEC privilege This guide is platform-specific.
802.1p CoS re-map table for Supplicant: 00:00:00:00:00:10 Dot1p 0 1 2 3 4 5 6 7 Dell# Remapped Dot1p 7 6 5 4 3 2 1 0 show dot1x interface Display the 802.1X configuration of an interface. Syntax show dot1x interface interface [mac-address mac-address] Parameters interface mac-address Defaults Enter one of the following keywords and slot/port[/subport] or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
Usage Information If you enable 802.1X multi-supplicant authentication on a port, additional 802.1X configuration details (Port Authentication status, Untagged VLAN ID, Authentication PAE state, and Backend state) display for each supplicant, as shown in the following example. Example Dell#show dot1x interface tengigabitethernet 1/32/1 802.
Dell# show dot1x interface gigabitethernet 1/32 mac-address 00:00:00:00:00:11 Supplicant Mac: 0 0 0 0 0 10 Lookup for Mac: 802.
00:00:00:00:00:11 Supplicant Mac: 0 0 0 0 0 10 Lookup for Mac: 802.
6 Access Control Lists (ACL) Access control lists (ACLs) are supported by the Dell Networking OS.
Command History • CONFIGURATION-EXTENDED-ACCESS-LIST • CONFIGURATION-MAC ACCESS LIST-STANDARD • CONFIGURATION-MAC ACCESS LIST-EXTENDED This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
• Command History CONFIGURATION-MAC ACCESS LIST-EXTENDED This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.
Version Description 6.2.1.1 Introduced on the E-Series. ip access-group Assign an IP access list (IP ACL) to an interface. Syntax ip access-group access-list-name {in | out} [implicit-permit] [vlan vlanid] [vrf vrf-name] To delete an IP access-group configuration, use the no ip access-group access-list-name {in | out} [implicit-permit] [vlan vlan-id] [vrf vrf-name] command. Parameters access-list-name Enter the name of a configured access list, up to 140 characters.
Usage Information You can assign one ACL (standard or extended ACL) to an interface. NOTE: This command supports Loopback interfaces EE3 and EF series route processor modules (RPMs). This command does not support Loopback interfaces ED series RPMs and S-Series Loopback interfaces. NOTE: If you apply outbound(egress) IP acl on a switch port, the filter applies only for routed traffic egressing out of that port. To associate an access-list to a non-default VRF, use the vrf attribute of this command.
• Command Modes Command History For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. in | out Identify whether ACL is applied on the ingress or egress side. vrf vrf-name (Optional) Enter the keyword vrf and then the name of the VRF to view the IP accounting information on either a default or a non-default VRF. • EXEC • EXEC Privilege This guide is platform-specific.
The supports both Ingress and Egress IP ACLs. NOTE: Also refer to the Commands Common to all ACL Types and Common IP ACL Commands sections. deny To drop packets with a certain IP address, configure a filter. Syntax deny {source | any | host {ip-address}} To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {source [mask] | any | host ip-address} command.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. The order option is relevant in the context of the Policy QoS feature only. For more information, refer to the Quality of Service chapter of the Dell Networking OS Configuration Guide.
Usage Information Version Description 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. Dell Networking OS supports one ingress and one egress IP ACL per interface. Prior to Dell Networking OS version 7.8.1.0, names are up to 16 characters long. The number of entries allowed per ACL is hardware-dependent.
Command Modes CONFIGURATION-STANDARD-ACCESS-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
count (OPTIONAL) Enter the keyword count to count packets the filter processes. bytes (OPTIONAL) Enter the keyword bytes to count bytes the filter processes. dscp (OPTIONAL) Enter the keyword dcsp to match to the IP DCSCP values. order (OPTIONAL) Enter the keyword order to specify the QoS order for the ACL entry. The range is from 0 to 254 (where 0 is the highest priority and 254 is the lowest; lower-order numbers have a higher priority).
permit — configures a filter to forward packets. Extended IP ACL Commands When an ACL is created without any rule and then applied to an interface, ACL behavior reflects an implicit permit. The following commands configure extended IP ACLs, which in addition to the IP address, also examine the packet’s protocol type. The supports both Ingress and Egress IP ACLs. NOTE: Also refer to the Commands Common to all ACL Types and Common IP ACL Commands sections.
monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. For more information, refer to the “Flow-based Monitoring” section in the Port Monitoring chapter of the Dell Networking OS Configuration Guide. fragments Enter the keyword fragments to use ACLs to control packet fragments. Defaults Not configured.
deny udp — assigns a filter to deny UDP packets. ip access-list extended — creates an extended ACL. deny icmp To drop all or specific internet control message protocol (ICMP) messages, configure a filter. Syntax deny icmp {source mask | any | host ip-address} {destination mask | any | host ip-address} [dscp] [count [byte] [order] [fragments] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number.
Usage Information Version Description 8.3.1.0 Added the keyword dscp. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.4.1.0 Added support for non-contiguous mask and added the monitor option. 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. The order option is relevant in the context of the Policy QoS feature only.
operator port port (OPTIONAL) Enter one of the following logical operand: • eq = equal to • neq = not equal to • gt = greater than • lt = less than • range = inclusive range of ports (you must specify two ports for the port command) Enter the application layer port number. Enter two port numbers if using the range logical operand. The range is from 0 to 65535.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for non-contiguous mask and added the monitor option. Deprecated the keyword established. 6.5.1.0 Expanded to include the optional QoS order priority for the ACL entry. The order option is relevant in the context of the Policy QoS feature only.
deny udp To drop user datagram protocol (UDP) packets meeting the filter criteria, configure a filter. Syntax deny udp {source mask | any | host ip-address} [operator port [port]] {destination mask | any | host ip-address} [dscp] [operator port [port]] [count [byte] [order] [fragments] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Added the keyword dscp. 8.
7 0001111100000000 1111111111000000 7936 7999 64 8 0001111101000000 1111111111111111 8000 8000 1 Total Ports: 4001 Example An ACL rule with a TCP port lt 1023 uses only one entry in the CAM. Rule# Data Mask From To 1 0000000000000000 1111110000000000 0 #Covered 1023 1024 Total Ports: 1024 Related Commands deny — assigns a filter to deny IP traffic. deny tcp — assigns a filter to deny TCP traffic.
Prior to 7.8.1.0, names are up to 16 characters long. Example Dell(conf)#ip access-list extended TESTListEXTEND Dell(config-ext-nacl)# Related Commands ip access-list standard — configures a standard IP access list. show config — displays the current configuration. permit To pass IP packets meeting the filter criteria, configure a filter.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Add the DSCP value for ACL matching. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.
bit Enter a flag or combination of bits: • ack: acknowledgement field • fin: finish (no more data from the user) • psh: push function • rst: reset the connection • syn: synchronize sequence numbers • urg: urgent field dscp Enter the keyword dscp to deny a packet based on the DSCP value. The range is from 0 to 63.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Added the keyword dscp. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.
Example An ACL rule with a TCP port lt 1023 uses only one entry in the CAM. Rule# Data Mask From To 1 0000000000000000 1111110000000000 0 #Covered 1023 1024 Total Ports: 1024 Related Commands ip access-list extended — creates an extended ACL. permit — assigns a permit filter for IP packets. permit udp — assigns a permit filter for UDP packets. permit udp To pass UDP packets meeting the filter criteria, configure a filter.
order (OPTIONAL) Enter the keyword order to specify the QoS priority for the ACL entry. The range is from 0 to 254 (where 0 is the highest priority and 254 is the lowest; lower-order numbers have a higher priority). If you do not use the keyword order, the ACLs have the lowest order by default (255). fragments Enter the keyword fragments to use ACLs to control packet fragments. Defaults Not configured. Command Modes CONFIGURATION-EXTENDED-ACCESS-LIST Command History This guide is platform-specific.
Example An ACL rule with a TCP port range of 4000–8000 uses eight entries in the CAM.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale (IPv4). 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names were up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series.
port port • eq = equal to • neq = not equal to • gt = greater than • lt = less than • range = inclusive range of ports (you must specify two ports for the port parameter.) (OPTIONAL) Enter the application layer port number. Enter two port numbers if you are using the range logical operand. The range is from 0 to 65535.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Add the DSCP value for ACL matching. 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added support for the non-contiguous mask and added the monitor option. Deprecated the keyword established. 6.5.
The MAC ACL can be applied on Physical, Port-channel and VLAN interfaces. As per the specified rules in the acl, the traffic on the interface/ VLAN members or Port-channel members will be permitted or denied. clear counters mac access-group Clear counters for all or a specific MAC ACL. Syntax clear counters mac access-group [mac-list-name] Parameters mac-list-name (OPTIONAL) Enter the name of a configured MAC access list. Command Modes EXEC Privilege Command History This guide is platform-specific.
NOTE: 1. If the MAC ACL is applied on VLAN, none of the VLAN members should have an access list applied for that VLAN. 2. If the MAC ACL is applied on a Physical or Port Channel interface, the VLAN in which this port is associated should not have an access list applied. 3. If the MAC ACL is applied on a VLAN, then that VLAN should not belong to VLAN ACL group. 4. If the MAC ACL is applied on a VLAN ACL group, then none of the VLANs in that group should have an access list applied on it.
in | out • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Identify whether ACL is applied on ingress or egress side. Command Modes EXEC Privilege Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.
• Parameters Use the no deny {any | mac-source-address mac-source-address-mask} command. any Enter the keyword any to specify that all routes are subject to the filter. mac-sourceaddress Enter a MAC address in nn:nn:nn:nn:nn:nn format. mac-sourceaddress-mask (OPTIONAL) Specify which bits in the MAC address must match. If no mask is specified, a mask of 00:00:00:00:00:00 is applied (in other words, the filter allows only MAC addresses that match).
seq — configures a MAC address filter with a specified sequence number. mac access-list standard To configure a standard MAC ACL, name a new or existing MAC access control list (MAC ACL) and enter MAC ACCESS LIST mode. Also refer to the Commands Common to all ACL Types section and the Common MAC Access List Commands section. Syntax mac access-list standard mac-list-name To delete a MAC access list, use the no mac access-list standard mac-list-name command.
permit To forward packets from a specific source MAC address, configure a filter. Syntax permit {any | mac-source-address [mac-source-address-mask]} [count [byte]] | [log] [monitor] To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no permit {any | mac-source-address mac-source-address-mask} command. any Enter the keyword any to forward all packets received with a MAC address.
Usage Information Version Description 6.1.1.0 Introduced on the E-Series. When you use the log option, the CP processor logs details about the packets that match. Depending on how many packets match the log entry and at what rate, the CP may become busy as it has to log these packets’ details. NOTE: When you configure the ACL logging and byte counters simultaneously, byte counters may display an incorrect value. Configure packet counters with logging instead.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {any | host mac-address | mac-source-address mac-sourceaddress-mask} {any | host mac-address | mac-destination-address macdestination-address-mask} command. any Enter the keyword any to drop all packets. host mac-address Enter the keyword host and then enter a MAC address to drop packets with that host address.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added the monitor option. 6.1.1.0 Introduced on the E-Series.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names were up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
• Parameters Use the no permit {any | host mac-address | mac-source-address mac-sourceaddress-mask} {any | mac-destination-address mac-destination-addressmask} command. any Enter the keyword any to forward all packets. host Enter the keyword host then a MAC address to forward packets with that host address. mac-sourceaddress Enter a MAC address in nn:nn:nn:nn:nn:nn format. mac-sourceaddress-mask (OPTIONAL) Specify which bits in the MAC address must match.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added the monitor option. 6.1.1.0 Introduced on the E-Series. When you use the log option, the CP processor logs details about the packets that match.
Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increase the name string to accept up to 140 characters. Prior to 7.8.1.0, names were up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. Sequence numbers for this filter are automatically assigned starting at sequence number 5. If you do not use the ge or le options, only packets with an exact match to the prefix are filtered. ip prefix-list Enter the PREFIX-LIST mode and configure a prefix list.
seq To a deny or permit filter in a prefix list while configuring the filter, assign a sequence number. Syntax seq sequence-number {deny | permit} {any} | [ip-prefix /nn {ge min-prefixlength} {le max-prefix-length}] | [bitmask number] To delete a specific filter, use the no seq sequence-number {deny | permit} {any} | [ipprefix {ge min-prefix-length} {le max-prefix-length}] | [bitmask number]. Parameters sequence-number Enter a number. The range is from 1 to 4294967294.
Usage Information If you do not use the ge or le options, only packets with an exact match to the prefix are filtered. show config Display the current PREFIX-LIST configurations. Syntax show config Command Modes PREFIX-LIST Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Example Version Description 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Usage Information The continue feature allows movement from one route-map entry to a specific route-map entry (the sequence number). If you do not specify the sequence number, the continue feature simply moves to the next sequence number (also known as an implied continue). If a match clause exists, the continue feature executes only after a successful match occurs. If there are no successful matches, the continue feature is ignored.
Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. pre-7.7.1.0 Introduced. route-map — enables a route map. match as-path To match routes that have a certain AS number in their BGP path, configure a filter.
match community To match routes that have a certain COMMUNITY attribute in their BGP path, configure a filter. Syntax match community community-list-name [exact] To delete a community match filter, use the no match community command. Parameters community-listname Enter the name of a configured community list. exact (OPTIONAL) Enter the keywords exact to process only those routes with this community list name. Defaults Not configured.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific.
Parameters prefix-list-name Enter the name of configured prefix list, up to 140 characters. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810 8.1.1.
Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. match interface — redistributes routes that match the next-hop interface.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. pre-6.1.1.0 Introduced on the E-Series. match route-type To match routes based on the how the route is defined, configure a filter.
Related Commands match interface — redistributes routes that match the next-hop interface. match ip address — redistributes routes that match an IP address. match ip next-hop — redistributes routes that match the next-hop IP address. match ip route-source — redistributes routes that match routes advertised by other routers. match metric — redistributes routes that match a specific metric. match tag — redistributes routes that match a specific tag.
match metric — redistributes routes that match a specific metric. match route-type — redistributes routes that match a route type. route-map Enable a route map statement and configure its action and sequence number. This command also places you in ROUTE-MAP mode. Syntax route-map map-name [permit | deny] [sequence-number] To delete a route map, use the no route-map map-name [permit | deny] [sequencenumber] command.
Example Dell(conf)#route-map dempsey Dell(config-route-map)# Related Commands show config — displays the current configuration. set as-path To modify the AS path for border gateway protocol (BGP) routes, configure a filter. Syntax set as-path prepend as-number [... as-number] To remove an AS-Path setting, use the no set as-path {prepend as-number | tag} command. Parameters prepend as-number Enter the keyword prepend and then enter up to eight AS numbers to be inserted into the BGP path information.
To return to the default, enter no set automatic-tag. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Increased the name string to accept up to 140 characters. Prior to 7.8.1.0, names are up to 16 characters long. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
All routes with the NO_ADVERTISE (0xFFFFFF02) community attribute must not be advertised to other BGP peers. no-export Enter the keywords no-export to drop all routes containing the well-known community attribute of NO_EXPORT. All routes with the NO_EXPORT (0xFFFFFF01) community attribute must not be advertised outside a BGP confederation boundary. none Enter the keyword none to remove the community attribute from routes meeting the route map criteria.
level-1-2 Enter the keyword level-1-2 to redistribute matched routes to IS-IS Level 1 and Level 2. level-2 Enter the keyword level-2 to redistribute matched routes to IS-IS Level 2. stub-area Enter the keyword stub to redistributed matched routes to OSPF stub areas. Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Dell Networking OS Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set automatic-tag — computes the tag value of the route. set level — specifies the OSPF area for route redistribution. set metric-type — specifies the route type assigned to redistributed routes.
Related Commands Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. set automatic-tag — computes the tag value of the route. set level — specifies the OSPF area for route redistribution. set metric — specifies the metric value assigned to redistributed routes. set tag — specifies the tag assigned to redistributed routes.
If you configure the set next-hop command with the interface’s IP address (either Loopback or physical), the software declares the route unreachable. Related Commands match ip next-hop — redistributes routes that match the next-hop IP address. set origin To manipulate the BGP ORIGIN attribute, configure a filter. Syntax set origin {igp | egp | incomplete} To delete an ORIGIN attribute setting, use the no set origin command.
Defaults Not configured. Command Modes ROUTE-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series.
show route-map Display the current route map configurations. Syntax show route-map [map-name] Parameters Command Modes Command History map-name • EXEC • EXEC Privilege (OPTIONAL) Enter the name of a configured route map, up to 140 characters. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny {source [mask] | any | host ip-address} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated.
Related Commands ip access-list standard — configures a standard ACL. permit — configures a permit filter. deny (for Extended IP ACLs) Configure a filter that drops IP packets meeting the filter criteria.
packet count for that new interval commences from zero. If ACL logging was stopped previously because the configured threshold is exceeded, it is re-enabled for this new interval. If ACL logging is stopped because the configured threshold is exceeded, it is re-enabled after the logging interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs.
Command Modes Command History Usage Information CONFIGURATION-STANDARD-ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
Defaults threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated. with the seq, permit, or deny commands. The threshold range is from 1 to 100. interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The interval range is from 1 to 10 minutes.
deny ether-type (for Extended MAC ACLs) Configure an egress filter that drops specified types of Ethernet packets on egress ACL supported line cards. (For more information, refer to your line card documentation).
MAC ACLs. You can configure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces. You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode.
Usage Information Version Description 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
Defaults interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The time interval range is from 1 to 10 minutes. monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
permit (for Standard IP ACLs) To permit packets from a specific source IP address to leave the switch, configure a filter. Syntax permit {source [mask]| any | host ip-address} [count [byte]] [dscp value] [order] [fragments] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no permit {source [mask] | any | host ip-address} command.
both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface. This feature is particularly useful when looking for malicious traffic. It is available for Layer 2 and Layer 3 ingress and egress traffic. You may specify traffic using standard or extended access-lists. This mechanism copies all incoming or outgoing packets on one port and forwards (mirrors) them to another port.
Usage Information Version Description 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled.
• Parameters Defaults Use the no permit icmp {source mask | any | host ip-address} {destination mask | any | host ip-address} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated with the seq, permit, or deny commands.
permit udp (for Extended IP ACLs) To pass UDP packets meeting the filter criteria, configure a filter. Syntax permit udp {source mask | any | host ip-address} [operator port [port]] {destination mask | any | host ip-address} [dscp] [operator port [port]] [count [byte]] [order] [fragments] [log [interval minutes] [threshold-inmsgs [count]][monitor] To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added the support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added the support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
Defaults threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated with the seq, permit, or deny commands. The threshold range is from 1 to 100. interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The interval range is from 1 to 10 minutes.
seq (for Standard MAC ACLs) To a deny or permit filter in a MAC access list while creating the filter, assign a sequence number. Syntax seq sequence-number {deny | permit} {any | mac-source-address [mac-sourceaddress-mask]} [count [byte]] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, use the no seq sequence-number command. Parameters Defaults log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
standard or extended access-lists. This mechanism copies all incoming or outgoing packets on one port and forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG). Related Commands deny — configures a filter to drop packets. permit — configures a filter to forward packets. permit tcp (for Extended IP ACLs) To pass TCP packets meeting the filter criteria, configure a filter.
Usage Information When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero. If ACL logging was stopped previously because the configured threshold is exceeded, it is re-enabled for this new interval.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is 5 minutes. By default, flow-based monitoring is not enabled.
address mac-address-mask | any} [count [byte]] [order] [log [interval minutes] [threshold-in-msgs [count]] [monitor] To remove this filter, use the no seq sequence-number command. Parameters Defaults log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages. threshold-in msgs count (OPTIONAL) Enter the threshold-in-msgs keyword followed by a value to indicate the maximum number of ACL logs that can be generated, exceeding which the generation of ACL logs is terminated.
forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG). seq (for IP ACLs) Assign a sequence number to a deny or permit filter in an extended IP access list while creating the filter.
You can activate flow-based monitoring for a monitoring session by entering the flow-based enable command in the Monitor Session mode. When you enable this capability, traffic with particular flows that are traversing through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specified traffic instead all traffic on the interface.
Usage Information Version Description 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information ACCESS-LIST Version Description 9.7(0.
Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no permit tcp {source address mask | any | host ipv6-address} {destination address | any | host ipv6-address} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
Related Commands permit – assigns a permit filter for IP packets. permit icmp (for IPv6 ACLs) To allow all or specific internet control message protocol (ICMP) messages, configure a filter.
If ACL logging is stopped because the configured threshold is exceeded, it is re-enabled after the logging interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs. You can configure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces.
Usage Information Version Description 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped. When the interval at which ACL logs are configured to be recorded expires, the subsequent, fresh interval timer is started and the packet count for that new interval commences from zero.
monitor Defaults (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled. Command Modes Command History Usage Information ACCESS-LIST Version Description 9.7(0.
To remove this filter, you have two choices: Parameters Defaults • Use the no seq sequence-number command if you know the filter’s sequence number. • Use the no deny arp {destination-mac-address mac-address-mask | any} vlan vlan-id {ip-address | any | opcode code-number} command. log (OPTIONAL) Enter the keyword log to enable the triggering of ACL log messages.
forwards (mirrors) them to another port. The source port is the monitored port (MD) and the destination port is the monitoring port (MG). deny tcp (for IPv6 ACLs) Configure a filter that drops TCP packets that match the filter criteria.
If ACL logging is stopped because the configured threshold is exceeded, it is re-enabled after the logging interval period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs. You can configure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs that are associated with egress interfaces.
Command Modes Command History Usage Information ACCESS-LIST Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4(0.0) Added support for flow-based monitoring on the S4810, S4820T, S6000, and Z9000 platforms. 9.3.0.0 Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms. When the configured maximum threshold is exceeded, generation of logs is stopped.
Defaults interval minutes (OPTIONAL) Enter the keyword interval followed by the time period in minutes at which ACL logs must be generated. The time interval range is from 1 to 10 minutes. monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the traffic that you want to monitor and the ACL in which you are creating the rule is applied to the monitored interface. By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
7 Bidirectional Forwarding Detection (BFD) Bidirectional forwarding detection (BFD) is a detection protocol that provides fast forwarding path failure detection.
ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.2.(0.0) Introduced BFD for VRRP and OSPFv3 on Z9000, S4810, and S4820T. 9.0.0.0 Introduced BFD for BGP on the Z9000. 8.3.19.
To disable BFD for all neighbors configured through static routes, use the no ip route bfd [interval interval min_rx min_rx multiplier value role {active | passive}] command. Parameters interval milliseconds (OPTIONAL) Enter the keywords interval to specify non-default BFD session parameters beginning with the transmission interval. The range is from 50 to 1000. The default is 100.
peer-group-name Enter the name of the peer group that you want to explicitly enable for BFD sessions. Defaults none Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
Defaults none Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.
8 Boot Command Line Interface To access this BOOT_USER mode, first boot your Dell Networking platform. When you see the “Press ESC to stop auto-boot”, press the ESC key to log into BCLI You enter BOOT_USER mode immediately, as indicated by the BOOT_USER# prompt. NOTE: All commands in this chapter are in Boot_User mode. These commands are supported on the Dell Networking platform. You cannot use the Tab key to complete commands in this mode.
Note: You must set the IP address of the designated download port before you execute this command. Otherwise, an second statement message alerts you that the configuration cannot proceed. shows the first field after you enter boot change primary. At this point: Example • Press Enter to accept the information already configured, or • Change that information. To do so, press the . (period) key and enter new information. After you enter the information, press Enter.
boot show net config retries Show the number of retries for network boot configuration failure. Syntax boot show net config retries Command Modes BOOT_USER Command History Example Version 9.0.2.0 Introduced on the S6000. BOOT_USER #boot show net config retries Number of Network Boot Config Retries is : 0 BOOT_USER # boot write net config retries Set the number of retries for network boot configuration failure.
default Defaults None Command Modes BOOT_USER Command History Usage Information Version 9.0.2.0 Enter the keyword default to configure boot parameters used if the secondary operating system boot parameter selection is not available. You can configure this option to any of the available type, for example flash/usb/ftp/tftp. Introduced on the S6000. This command reverses changes made with the boot change command.
Parameters Command Modes Command History ip-address Enter the IP address of the gateway router in dotted decimal format (A.B.C.D). BOOT_USER Version 9.0.2.0 Introduced on the S6000. Usage Information Use the show default-gateway command to view the current default gateway. Related Commands show_default-gateway— Change the primary, secondary, or default boot image configuration. etheraddr Assign the management port MAC address.
Usage Information When you enter the reload command and the system reboots, you will not be prompted for a password to enter the EXEC Privilege mode (normally you are required to enter the enable command). If your console or Telnet session expires after you used the ignore enable-password command, you are prompted for an enable password when you re-establish the session Related Commands reload — Exit from this mode and reload FTOS.
show_interface_mangement_ethernet— Display the IP address configured for the Management interface. NVRAM erase Erase all NVRAM contents alone. Syntax Parameters Command Modes Command History nvram erase mac-address Enter a MAC address in standard format. BOOT_ADMIN Version 9.0.2.0 Introduced on the S6000. Usage Information Use this command to assign a MAC address if FTOS cannot find a default MAC address.
Parameters serial console [unit] [baud] Enter the keyword to set the serial port baud rate. The supported values for serial console: • Unit - 0 • Baud rate -9600,115200 No defaults. Command Modes Command History Example Serial BOOT_USER Version 9.0.2.0 Introduced on the S6000. BOOT_USER # serial console 0 9600 BOOT_USER # BOOT_USER # show bootvar Display boot configuration information. Syntax show bootvar Command Modes BOOT_USER Command History Example Version 9.0.2.
file name : PS-SI-9-0-0-566.bin Management Etherenet IP address : 10.16.133.17 Mask : 255.255.0.0 Server IP address : 10.16.1.200 Default Gateway IP address : 10.16.1.254 BOOT_USER # Related Commands boot_change— Change the primary, secondary, or default boot image configuration. boot_zero — Erase the configured primary, secondary, or default boot image parameters. show default-gateway Display the IP address configured for the default gateway.
Example BOOT_USER # show interfaces management ethernet Management ethernet IP address: 10.16.133.17/24 BOOT_ADMIN # On the S6000, the output of this command includes the MAC address and port number of the assigned management port. Example BOOT_ADMIN # show int man eth Management ethernet IP address: 10.16.132.4/16 BOOT_ADMIN # Related Commands interface_management_ethernet_ip_address — Assign an IP address to the Management Ethernet interface.
settimeout Enter the keyword set timeout to set timeout. NOTE: By default, watchdog is disabled. Command Modes Command History Example BOOT_ADMIN Version 9.0.2.0 Introduced on the S6000.
9 Border Gateway Protocol BGP is an external gateway protocol that transmits interdomain routing information within and between autonomous systems (AS). BGP version 4 (BGPv4) supports classless inter-domain routing (CIDR) and the aggregation of routes and AS paths. Basically, two routers (called neighbors or peers) exchange information including full routing tables and periodically sent messages to update those routing tables.
NOTE: Use this attribute to start a BGP instance corresponding to either a specific address family in a default VRF or an IPv4 address family in a nondefault VRF. ipv6 unicast Enter the keyword ipv6 followed by the keyword unicast to enable BGPv6 mode. vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to install the IPv6 route in that VRF. NOTE: It will not be possible to enable VRF mode for IPv6 unicast without configuring the corresponding IPv4 unicast mode for the same VRF.
Defaults attribute-map mapname (OPTIONAL) Enter the keywords attribute-map then the name of a configured route map to modify attributes of the aggregate, excluding AS_PATH and NEXT_HOP attributes. summary-only (OPTIONAL) Enter the keyword summary-only to advertise only the aggregate address. Specific routes are not advertised. suppress-map mapname (OPTIONAL) Enter the keywords suppress-map then the name of a configured route map to identify which more-specific routes in the aggregate are suppressed.
The attribute-map corresponding to an aggregate address is applied during the outbound update creation time; hence the value set in that attribute-map will not be shown in the output of the show ip bgp aggregate route command. bgp add-path Allow the advertisement of multiple paths for the same address prefix without the new paths replacing any previous ones.
Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
Usage Information Before enabling this feature, enable the enable bgp four-octet-as-supportcommand. If you disable the four-octect-support command after using dot or dot+ format, the AS numbers revert to asplain text. When you apply an asnotation, it is reflected in the running-configuration. If you change the notation type, the running-config updates dynamically and the new notation shows.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. If you enable this command, use the clear ip bgp * command to recompute the best path. bgp bestpath as-path multipath-relax Include prefixes received from different AS paths during multipath calculation.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Usage Information The MED is a 4-byte unsigned integer value and the default behavior is to assume a missing MED as 4294967295. This command causes a missing MED to be treated as 0. During path selection, paths with a lower MED are preferred over paths with a higher MED. bgp bestpath router-id ignore Do not compare router-id information for external paths during best path selection. Syntax bgp bestpath router-id ignore To return to the default selection, use the no bgp bestpath router-id ignore command.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Usage Information Route reflection to clients is not necessary if all client routers are fully meshed. Related Commands bgp cluster-id — assigns an ID to a BGP cluster with two or more route reflectors. neighbor route-reflector-client — configures a route reflector and clients.
cluster-id command. Without a cluster ID, the route reflector cannot recognize route updates from the other route reflectors within the cluster. The default format for displaying the cluster-id is dotted decimal, but if you enter the cluster-id as an integer, it is displayed as an integer. This command automatically restarts the BGP instance for the configuration to take effect. Related Commands bgp client-to-client reflection — enables route reflection between the route reflector and clients.
The autonomous systems configured in this command are visible to the EBGP neighbors. Each autonomous system is fully meshed and contains a few connections to other autonomous systems. The next hop, MED, and local preference information is preserved throughout the confederation. Dell Networking OS accepts confederation EBGP peers without a LOCAL_PREF attribute. The software sends AS_CONFED_SET and accepts AS_CONFED_SET and AS_CONF_SEQ.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. Added support for the 4-byte format. All the routers in the Confederation must be 4 byte or 2 byte identified routers. You cannot mix them. The autonomous systems configured in this command are visible to the EBGP neighbors. Each autonomous system is fully meshed and contains a few connections to other autonomous systems.
Command Modes Command History • ROUTER BGP • ROUTER BGP-address-family This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Usage Information All routers apply the bgp default local-preference command setting within the AS. To set the local preference for a specific route, use the set local-preference command in ROUTE-MAP mode.
bgp enforce-first-as Disable (or enable) enforce-first-as check for updates received from EBGP peers. Syntax bgp enforce-first-as To turn off the default, use the no bgp enforce-first-as command. Defaults Enabled Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
To disable fast external fallover, use the no bgp fast-external-fallover command. Defaults Enabled Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Routers supporting 4-byte ASNs advertise that function in the OPEN message. The behavior of a 4-byte router is slightly different depending on whether it is speaking to a 2-byte router or a 4-byte router. When creating Confederations, all the routers in the Confederation must be 4 byte or 2 byte identified routers. You cannot mix them.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. This feature is advertised to BGP neighbors through a capability advertisement. In Receiver Only mode, BGP saves the advertised routes of peers that support this capability when they restart. BGP graceful restart is active only when the neighbor becomes established. Otherwise it is disabled.
When you change the path selection from Deterministic to Non-Deterministic, the path selection for the existing paths remains Deterministic until you enter the clear ip bgp command to clear existing paths. bgp recursive-bgp-next-hop Enable next-hop resolution through other routes learned by BGP. Syntax bgp recursive-bgp-next-hop To disable next-hop resolution, use the no bgp recursive-bgp-next-hop command. Defaults Enabled Command Modes ROUTER BGP Command History This guide is platform-specific.
Command Modes ROUTER BGP (conf-router_bgp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
bgp router-id Assign a user-given ID to a BGP router. Syntax bgp router-id ip-address To delete a user-assigned IP address, use the no bgp router-id command. Parameters ip-address Enter an IP address in dotted decimal format to reset only that BGP neighbor. Defaults The router ID is the highest IP address of the Loopback interface or, if no Loopback interfaces are configured, the highest IP address of a physical interface on the router.
NOTE: Use this attribute to clear a BGP instance corresponding to either a specific address family in a default VRF or an IPv4 address family in a a non-default VRF. * Enter an asterisk ( * ) to reset all BGP sessions. <1-4294967295> Enter <1-4294967295> to clear peers with the AS number. <0.1-65535.65535> Enter <0.1-65535.65535> to clear peers with the AS number in dot format. A.B.C.D Enter the BGP neighbor address in the A.B.C.D format to clear.
Related Commands bgp recursive-bgp-next-hop — disables next-hop resolution through other routes learned by the BGP. clear ip bgp dampening Clear information on route dampening and return the suppressed route to the Active state.
The clear ip bgp dampening command does not clear the history paths. clear ip bgp flap-statistics Clear BGP flap statistics, which includes number of flaps and the time of the last flap.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
out Enter the keyword out to re-configure soft outbound updates. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000.
ipv6 Enter the ipv6 IP address to view the IPV6 route information. keepalives Enter the keyword keepalives to view BGP keepalives. notifications Enter the keyword notifications to view BGP notifications. soft-reconfiguration Enter the keywords soft-reconfiguration to view only information on inbound BGP soft reconfiguration. updates Enter the keyword updates to view BGP updates. Command Modes EXEC Privilege Command History This guide is platform-specific.
Parameters vrf vrf-name Enter the keyword vrf followed by the name of the VRF to view information on dampened routes corresponding to that VRF. ipv4 multicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword multicast to view dampened-route information related only to ipv4 multicast routes. ipv4 unicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword multicast to view dampened-route information related only to ipv4 unicast routes.
in (OPTIONAL) Enter the keyword in to view only events on inbound BGP messages. out (OPTIONAL) Enter the keyword out to view only events on outbound BGP messages. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. To remove all configured debug commands for BGP, enter the no debug ip bgp command. debug ip bgp soft-reconfiguration Enable soft-reconfiguration debug. Syntax debug ip bgp [vrf vrf-name] [A.B.C.
Usage Information Version Description 7.2.1.0 Introduced. This command turns on BGP soft-reconfiguration inbound debugging. If no neighbor is specified, debug turns on for all neighbors. debug ip bgp updates Allows you to view information about BGP updates. Syntax debug ip bgp [vrf vrf-name] [A.B.C.D | X:X:X:X::X | peer-group peer-groupname] updates [in | out | prefix-list prefix-list-name] To disable debugging, use the no debug ip bgp [vrf vrf-name] [A.B.C.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. To remove all configured debug commands for BGP, enter the no debug ip bgp command. default-metric Allows you to change the metric of redistributed routes to locally originated routes. Use this command with the redistribute command. Syntax default-metric number To return to the default setting, use the no default-metric command.
deny bandwidth Enables you to specify link band width extended-community attribute as the matching criteria to deny incoming or outgoing traffic. Syntax deny bandwidth To disable this setting, enter the no deny bandwidth command. Parameters bandwidth Enter the keyword bandwidth to specify extended-community attribute as the matching criteria for denying traffic. The range is from 0 to 102400.
Related Commands Version Description pre-7.7.1.0 Introduced. router bgp — enters ROUTER mode on the switch. maximum-paths Configure the maximum number of parallel routes (multipath support) BGP supports. Syntax maximum-paths {ebgp | ibgp} number To return to the default values, enter the no maximum-paths command. Parameters ebgp Enter the keyword ebgp to enable multipath support for External BGP routes. ibgp Enter the keyword ibgp to enable multipath support for Internal BGP routes.
To disable, use the no neighbor [ip-address | peer-group-name] activate command. Parameters ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. peer-group-name (OPTIONAL) Enter the name of the peer group. activate Enter the keyword activate to enable the neighbor/peer group in the new AFI/ SAFI. Defaults Disabled Command Modes CONFIGURATION-ROUTER-BGP-ADDRESS FAMILY Command History This guide is platform-specific.
path-count Enter the number paths supported. The range is from 2 to 64. Defaults none Command Modes CONFIGURATION-ROUTER-BGP-ADDRESS FAMILY Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. neighbor advertisement-start To send BGP routing updates, set the minimum interval before starting.
neighbor allowas-in Set the number of times an AS number can occur in the AS path. Syntax neighbor {ip-address | peer-group-name} allowas-in number To return to the default value, use the no neighbor {ip-address | peer-group-name} allowas-in command. Parameters ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group to set the advertisement interval for all routers in the peer group.
Parameters ip-address (OPTIONAL) Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group to set the default route of all routers in that peer group. route-map mapname (OPTIONAL) Enter the keyword route-map then the name of a configured route map. Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific.
neighbor description Assign a character string describing the neighbor or group of neighbors (peer group). Syntax neighbor {ip-address | peer-group-name} description text To delete a description, use the no neighbor {ip-address | peer-group-name} description command. Parameters ip-address Enter the IP address of the neighbor in dotted decimal format. peer-group-name Enter the name of the peer group. text Enter a continuous text string up to 80 characters. Defaults Not configured.
prefix-list-name Enter the name of an established prefix list. If the prefix list is not configured, the default is permit (to allow all routes). in Enter the keyword in to distribute only inbound traffic. out Enter the keyword out to distribute only outbound traffic. Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Version Description 7.4.1.0 Introduced Usage Information When you enable failover, BGP keeps track of IP or IPv6 ability to reach the peer remote address and the peer local address. Whenever either address becomes unreachable (for example, no active route exists in the routing table for the peer IP or IPv6 destination/local address), BGP brings down the session with the peer. Related Commands show ip bgp neighbors — displays information on the BGP neighbors.
Usage Information If a local-as is configured, BGP does not allow for the configuration of BGP confederation. Similarly, if BGP confederation is configured, then BGP does not allow the configuration of local-as. This command automatically restarts the neighbor session for the configuration to take effect. Related Commands bgp four-octet-as-support — enables 4-byte support for the BGP process. neighbor maximum-prefix Control the number of network prefixes received.
Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Usage Information If you configure the neighbor maximum-prefix command and the neighbor receives more prefixes than the neighbor maximum-prefix command configuration allows, the neighbor goes down and the show ip bgp summary command displays (prfxd) in the State/PfxRcd column for that neighbor.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. This command automatically restarts the neighbor session for the configuration to take effect. Configure the same password on both BGP peers or a connection does not occur. When you configure MD5 authentication between two BGP peers, each segment of the TCP connection between them is verified and the MD5 digest is checked on every segment sent on the TCP connection.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added the dmzlink-bw parameter. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
To delete a peer group, use the no neighbor peer-group-name peer-group command. Parameters peer-group-name Enter a text string up to 16 characters long as the name of the peer group. Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced the limit keyword on the S4810. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series.
Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Added 4-byte support. To accept 4-byte formats before entering a 4 byte AS Number, configure your system.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Added 4-byte support. Applies to EBGP neighbors only. Configure your system to accept 4-byte formats before entering a 4 byte AS Number. If the AS-PATH contains both public and private AS number or contains AS numbers of an EBGP neighbor, the private AS numbers are not removed.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. When you apply a route map to outbound routes, only routes that match at least one section of the route map are permitted.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. A route reflector reflects routes to the neighbors assigned to the cluster. Neighbors in the cluster do not need not to be fully meshed. By default, when you use no route reflector, the internal BGP (IBGP) speakers in the network must be fully meshed. The first time you enter this command, the router configures as a route reflector and the specified BGP neighbors configure as clients in the route-reflector cluster.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. Peers that are enabled within a peer group are disabled when their peer group is disabled. The neighbor shutdown command terminates all BGP sessions on the BGP neighbor or BGP peer group. Use this command with caution as it terminates the specified BGP sessions. When a neighbor or peer group is shut down, use the show ip bgp summary command to confirm its status.
Usage Information This command enables soft-reconfiguration for the BGP neighbor specified. BGP stores all the updates the neighbor receives but does not reset the peer-session. You cannot set this configuration for a peer that is associated with a peer group. Similarly, you cannot associate a peer to a peer group if that peer is already configured with these settings. CAUTION: Inbound update storage is a memory-intensive operation.
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Timer values configured with the neighbor timers command override the timer values configured with any other command.
Usage Information Loopback interfaces are up constantly and the BGP session may need one interface constantly up to stabilize the session. The neighbor update-source command is not necessary for directly connected internal BGP sessions. Neighbors are sorted according to the source and destination ip addresses. If an update-source ip address exists, then the source ip address determines the order in which the neighbors are displayed.
network Specify the networks for the BGP process and enter them in the BGP routing table. Syntax network ip-address mask [route-map map-name] To remove a network, use the no network ip-address mask [route-map map-name] command. Parameters ip-address Enter an IP address in dotted decimal format of the network. mask Enter the mask of the IP address in the slash prefix length format (for example, / 24). The mask appears in command outputs in dotted decimal format (A.B.C.D).
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. Dell Networking OS software resolves the network address the network command configures with the routes in the main routing table to ensure that the networks are reachable using non-BGP routes and nondefault routes. As BGP does not query next-hop information corresponding to locally originated routes, a local route with an unreachable next-hop is chosen as the best route.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. Although Dell Networking OS does not generate a route due to the backdoor config, there is an option for injecting/sourcing a local route in the presence of network backdoor config on a learned route.
• match ip address • set community • set local-preference • set metric • set next-hop • set origin • set weight If the route map is not configured, the default is deny (to drop all routes). Defaults Not configured. Command Modes ROUTER BGP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Related Commands neighbor default-originate — injects the default route. redistribute ospf Redistribute OSPF routes into BGP. Syntax redistribute ospf process-id [[match external {1 | 2}] [match internal]] [route-map map-name] To stop redistribution of OSPF routes, use the no redistribute ospf process-id command. Parameters process-id Enter the number of the OSPF process. The range is from 1 to 65535.
router bgp To configure and enable BGP, enter ROUTER BGP mode. Syntax router bgp as-number To disable BGP, use the no router bgp as-number command. Parameters as-number Enter the AS number. The range is from 1 to 65535 (2 byte), from 1 to 4294967295 (4 byte), or from 0.1 to 65535.65535 (dotted format). Defaults Not enabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Parameters bandwidth Defaults N/A Command Modes ROUTER MAP Command History Usage Information Enter the keyword bandwidth to enable extended community bandwidth. The range is from 0 to 102400. Version Description 9.7(0.0) Introduced on the S-Series. A new policy command is introduced in order to attach the Link Bandwidth extended community only to the prefixes that are received from a neighbor that satisfy the desired conditions.
Incoming packet capture enabled for BGP neighbor 20.20.20.
neighbor 10.1.1.2 remote-as 200 neighbor 10.1.1.2 no shutdown show ip bgp View the current BGP IPv4 routing table for the system. Syntax Parameters Command Modes Command History show ip bgp [vrf vrf-name] [ipv4 unicast] [network [network-mask] [longerprefixes]] vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to view ipv4– unicast route information corresponding to that VRF.
The following describes the show ip bgp command shown in the following example. Field Description Network Displays the destination network prefix of each BGP route. Next Hop Displays the next hop address of the BGP router. If 0.0.0.0 is listed in this column, then local routes exist in the routing table. Metric Displays the BGP route’s metric, if assigned. LocPrf Displays the BGP LOCAL_PREF attribute for the route. Weight Displays the route’s weight.
Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to view cluster information of BGP neighbors corresponding to that VRF. ipv4 multicast (OPTIONAL) Enter the keywords ipv4 followed by the keyword multicast to view information related only to ipv4 multicast routes. ipv4 unicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword unicast to view information related only to ipv4 multicast routes.
Status codes: s suppressed, S stale, d dampened, h history, * valid, > best Path source: I - internal, a - aggregate, c - confed-external, r redistributed n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete *>I 500 *>I *>I Network 55.0.0.0/24 600 i 66.0.0.0/24 77.0.0.0/24 Next Hop 172.16.0.2 Metric 172.16.0.2 172.16.0.2 LocPrf Weight Path 0 0 400 0 0 0 500 i 0 i Dell#show ip bgp cluster-list 4.4.4.
All routes with the NO_EXPORT_SUBCONFED (0xFFFFFF03) community attribute must not be advertised to external BGP peers. no-advertise Enter the keywords no-advertise to view all routes containing the well-known community attribute of NO_ADVERTISE. All routes with the NO_ADVERTISE (0xFFFFFF02) community attribute must not be advertised to other BGP peers. no-export Enter the keywords no-export to view all routes containing the well-known community attribute of NO_EXPORT.
Example Field Description LocPrf Displays the BGP LOCAL_PREF attribute for the route. Weight Displays the route’s weight. Path Lists all the ASs the route passed through to reach the destination network.
Command Modes Command History community-listname Enter the name of a configured IP community list (maximum 140 characters). exact-match Enter the keyword for an exact match of the communities. • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete Network Next Hop Metric LocPrf Weight Path *> 55.0.0.0/24 172.16.0.2 0 200 i Dell#show ip bgp 55.0.0.0/24 BGP routing table entry for 55.0.0.0/24 Paths: (1 available, table Default-IP-Routing-Table.) Not advertised to any peer Received from : 172.16.0.2 (172.16.0.2) AS_PATH : 200 Best Next-Hop : 172.16.0.
Usage Information Version Description 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. To determine a BGP session flap, both a route-down event and a subsequent route-up event corresponding to a single route are considered. As a result, a flap event is penalized only one time during the route-down event. The subsequent route-up event corresponding to the same route is not considered as a flap and is not penalized.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Introduced.
FixedPartCrt 1 : VarParCrt 1 Packet Capture max allowed length 40960000 : current length 0 Peer Grp List Nbr List Confed Peer List Address Family specific Information AFIndex 0 NdSpFlag 0x41a190b0 : AFRttP 0x41a0d200 : NdRTMMkrP 0x41a19d28 : NdRTMAFTblVer 0 : NdRibCtxAddr 1101110688 NdRibCtxAddrLen 255 : NdAFPrefix 0 : NdAfNLRIP 0 : NdAFNLRILen 0 : NdAFWPtrP 0 NdAFWLen 0 : NdAfNH : NdAFRedRttP 0x41a0d400 : NdRecCtxAdd 1101110868 NdRedCtxAddrLen 255 : NdAfRedMkrP 0x41a19e88 : AFAggRttP 0x41a0d600 : AfAggCtxA
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series.
Command Modes Command History ipv4 unicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword unicast to view information related only to ipv4 unicast routes. ipv6 unicast (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to view information related only to ipv6 unicast routes. as-path-name Enter an AS-PATH access list name. The range is 140 characters. • EXEC • EXEC Privilege This guide is platform-specific.
Example Dell#show run as-path a1 ! ip as-path access-list a1 permit 500 Dell# Dell#show ip bgp filter-list a1 BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.5 Status codes: s suppressed, S stale, d dampened, h history, * valid, > best Path source: I - internal, a - aggregate, c - confed-external, r redistributed n - network, D - denied, S - stale Origin codes: i - IGP, e - EGP, ? - incomplete *> 400 *> 500 Network 55.0.0.0/24 500 600 i 66.0.0.
NOTE: Enter an escape sequence (CTRL+v) prior to entering the ? regular expression. Command Modes Command History • EXEC • EXEC Privilege • [ ] = (brackets) a range of single-character patterns. • ( ) = (parenthesis) groups a series of pattern elements to a single element. • { } = (braces) minimum and the maximum match count. • ^ = (caret) the beginning of the input string. If you use the caret at the beginning of a sequence or range, it matches on everything BUT the characters specified.
Origin codes: i - IGP, e - EGP, ? - incomplete Network From Reuse Path h 77.0.0.0/24 172.16.0.2 00:00:00 d 55.0.0.0/24 172.16.0.2 00:30:44 200 i *> 66.0.0.0/24 172.16.0.2 00:00:00 200 i Dell#*>n 66.66.77.77/32 0.0.0.0 Flaps 0 Duration 1 00:00:03 3 00:00:25 1 00:00:23 32768 i show ip bgp inconsistent-as View routes with inconsistent originating autonomous system (AS) numbers; that is, prefixes that are announced from the same neighbor AS but with a different AS-Path.
Example Field Description Metric Displays the BGP route’s metric, if assigned. LocPrf Displays the BGP LOCAL_PREF attribute for the route. Weight Displays the route’s weight. Path Lists all the ASs the route passed through to reach the destination network. Dell>show ip bgp inconsistent-as BGP table version is 280852, local router ID is 10.1.2.
show ip bgp neighbors Allows you to view the information BGP neighbors exchange. Syntax show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] neighbors [ip-address [advertised-routes | dampened-routes | detail | flapstatistics | routes | {received-routes [network [network-mask]]} | {deniedroutes [network [network-mask]]}] Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to view information exchanged by BGP neighbors corresponding to that VRF.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added the ipv4 multicast and ipv6 unicast parameters. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.
The Lines Beginning with: Description • Example keepalive interval is the number of seconds between keepalive messages to help ensure that the TCP session is still alive. Received messages This line displays the number of BGP messages received, the number of notifications (error messages), and the number of messages waiting in a queue for processing.
Capabilities advertised to neighbor for IPv4 Unicast : MULTIPROTO_EXT(1) ROUTE_REFRESH(2) ADD_PATH(69) CISCO_ROUTE_REFRESH(128) For address family: IPv4 Unicast BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 InQ : Added 0, Replaced 0, Withdrawn 0 OutQ : Added 0, Withdrawn 0 Allow local AS number 0 times in AS-PATH attribute Prefixes accepted 2, withdrawn 15 by peer, martian prefixes ignored 0 Prefixes advertised 0, denied 0, withdrawn 0 from peer Connections established 1; dropped 0 Last res
Usage Information Example The following describes the show ip bgp next-hop command shown in the following example. Field Description Next-hop Displays the next-hop IP address. Via Displays the IP address and interface used to reach the next hop. RefCount Displays the number of BGP routes using this next hop. Cost Displays the cost associated with using this next hop. Flaps Displays the number of times the next hop has flapped.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Added support for VRF for the S4810, S4820T, and S6000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Command Modes Command History ipv4 unicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword unicast to view information related only to ipv4 unicast routes. ipv6 unicast (OPTIONAL) Enter the keyword ipv6 followed by the keyword unicast to view information related only to ipv6 unicast routes. peer-group-name (OPTIONAL) Enter the name of a peer group to view information about that peer group only.
Example Line beginning with: Description Number of peers Displays the number of peers currently configured for this peer group. Peer-group members: Lists the IP addresses of the peers in the peer group. If the address is outbound optimized, an * is displayed next to the IP address.
Command Modes Command History • EXEC • EXEC Privilege • ^ = (caret) the beginning of the input string. If you use the caret at the beginning of a sequence or range, it matches on everything BUT the characters specified. • $ = (dollar sign) the end of the output string. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show ip bgp summary Allows you to view the status of all BGP connections. Syntax show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] summary Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to view the status of all BGP connections corresponding to that VRF. ipv4 multicast (OPTIONAL) Enter the keyword ipv4 followed by the keyword multicast to view information related only to ipv4 multicast routes.
entry for each peer is created, as the next-hop is different. As a result, the BGP attributes count in the summary output will differ accordingly. The following describes the show ip bgp summary command shown in the following example. Field Description BGP router identifier Displays the local router ID and the AS number. BGP table version Displays the BGP table version and the main routing table version.
Field Description If a maximum limit was configured with the neighbor maximum-prefix command, (prfxd) appears in this column. If the neighbor is not in Established stage, the current stage is displayed (Idle, Connect, Active, OpenSent, OpenConfirm). When the peer is transitioning between states and clearing the routes received, the phrase (Purging) may appear in this column. If the neighbor is disabled, the phrase (Admin shut) appears in this column.
Example Version Description 7.6.1.0 Introduced on the E-Series. Dell#show running-config bgp ! router bgp 100 network 1.1.11.1/32 network 1.1.12.1/32 network 1.1.13.1/32 neighbor 10.1.1.2 remote-as 200 neighbor 10.1.1.2 no shutdown Dell# timers bgp Adjust the BGP Keep Alive and Hold Time timers. Syntax timers bgp keepalive holdtime To return to the default, use the no timers bgp command.
MBGP Commands Multiprotocol BGP (MBGP) is an enhanced BGP that enables multicast routing policy throughout the internet and connecting multicast topologies between BGP and autonomous systems (ASs). Dell Networking OS MBGP is implemented as per IETF RFC 1858. BGPv4 is supported in the following: Dell Networking OS Version Platform Support 7.8.1.0, MBGP for IPv4 Multicast Only S-Series debug ip bgp dampening View information on routes being dampened.
Version Description 7.6.1.0 Introduced IPv6 MGBP support for the E-Series. distance bgp Define an administrative distance for routes. Syntax distance bgp external-distance internal-distance local-distance To return to default values, use the no distance bgp command. Parameters Defaults external-distance Enter a number to assign to routes learned from a neighbor external to the AS. The range is from 1 to 255. The default is 20.
show ip bgp dampened-paths View BGP routes that are dampened (non-active). Syntax show ip bgp [vrf vrf-name] [ipv4 {multicast | unicast} | ipv6 unicast] dampened-paths Parameters Command Modes Command History vrf vrf-name (OPTIONAL) Enter the keywords vrf and then the name of the VRF to view routes that are affected by a specific community list corresponding to that VRF.
Example Field Description From Displays the IP address of the neighbor advertising the dampened route. Reuse Displays the hour:minutes:seconds until the dampened route is available. Path Lists all the ASs the dampened route passed through to reach the destination network. Dell#show ip bgp dampened-paths BGP local RIB : Routes to be Added 0, Replaced 0, Withdrawn 0 BGP local router ID is 192.168.11.
10 Content Addressable Memory (CAM) Content addressable memory (CAM) commands are supported on the Dell Networking platform. NOTE: Not all CAM commands are supported on all platforms. Be sure to note the platform when looking for a command. WARNING: If you are using these features for the first time, contact Dell Networking Technical Assistance Center (TAC) for guidance. CAM Profile Commands The CAM profiling feature allows you to partition the CAM to best suit your application.
number] ecfmacl number [nlbclusteracl number] ipv4pbr number }openflow number | fcoe number} [iscsioptacl number] [vrfv4acl number] Parameters default Use the default CAM profile settings and set the CAM as follows: • L2Acl : 6 • IPV4Acl : 4 • IPV6Acl : 0 • IPV4Qos : 2 • L2Qos : 1 • L2PT : 0 • IpMacAcl : 0 • VmanQos : 0 • VmanDualQos : 0 • EcfmAcl : 0 • nlbclusteracl: 0 • FcoeAcl : 0 • iscsiOptAcl : 0 • ipv4pbr : 0 • vrfv4Acl :0 • Openflow : 0 • fedgovacl : 0 l2acl number
Ipv4pbr number Enter the keyword ipv4pbr and then the number of FP blocks for ipv4pbr ACL. The range is from 0 to 8. Openflow number Enter the keyword openflow and then the number of FP blocks for open flow (multiples of 4). The range is from 0 to 8. fcoeacl number Enter the keyword fcoeacl and then the number of FP blocks for FCOE ACL. The range is from 0 to 6. Iscsioptacl number Enter the keyword iscsioptacl and then the number of FP blocks for iSCSI optimization ACL. The range is from 0 to 2.
Usage Information Save the new CAM settings to the startup-config (write-mem or copy run start) then reload the system for the new settings to take effect. The total amount of space allowed is 16 FP Blocks. System flow requires three blocks; these blocks cannot be reallocated. Only 13 number of blocks can be configured by the user . The ipv6acl allocation must be a factor of 2. If allocation values are not entered for the CAM regions, the value is 0.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
Example Dell#show cam-acl -- Chassis Cam ACL -Current Settings(in block sizes) 1 block = 256 entries L2Acl : 2 Ipv4Acl : 4 Ipv6Acl : 4 Ipv4Qos : 2 L2Qos : 1 L2PT : 0 IpMacAcl : 0 VmanQos : 0 EcfmAcl : 0 FcoeAcl : 0 iscsiOptAcl : 0 ipv4pbr : 0 vrfv4Acl : 0 Openflow : 0 fedgovacl : 0 nlbclusteracl: 0 -- stack-unit 1 -Current Settings(in block sizes) 1 block = 256 entries L2Acl : 2 Ipv4Acl : 4 Ipv6Acl : 4 Ipv4Qos : 2 L2Qos : 1 L2PT : 0 IpMacAcl : 0 VmanQos : 0 EcfmAcl : 0 FcoeAcl : 0 iscsiOptAcl : 0 ipv4pbr :
test cam-usage Verify that enough CAM space is available for the IPv6 ACLs you have created. Syntax test cam-usage service-policy input input policy name stack-unit {number | all} Parameters policy-map name Enter the name of the policy-map to verify. Maximum is 32 characters. number Enter all to get information for all the linecards/stack-units or enter the linecard/ stack-unit number to get information for a specific card. The range is 0-7 for all other S-Series. The range is 1-6.
Term Explanation Status Indicates whether or not the policy will be allowed in the CAM.
Important Points to Remember • All line cards/Stack Members within a single system must have the same UFT mode profiles. this profile must match the system UFT mode profile (the profile on the primary route processor module [RPM]/ Master Unit of the Stack). • The UFT mode configuration is applied to the entire system when you use the CONFIGURATION mode commands. Save the running-configuration to affect the change. • You MUST save your changes and reboot the system for UFT mode profiling to take effect.
L2 MAC Entries L3 Host Entries L3 Route Entries : : : 160K 144K 16K 96K 208K 16K Dell# Related Commands hardware forwarding-table mode — selects the mode to initialize the maximum scalability size for L2 MAC table or L3 Host table or L3 Route table.
11 Control Plane Policing (CoPP) The CoPP commands are supported on the Dell Networking platform. control-plane-cpuqos To manage control-plane traffic, enter control-plane mode and configure the switch. Syntax control-plane-cpuqos Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810.
Usage Information Version Description 8.3.8.0 Introduced on the S4810. This command applies the service-policy based on the type of protocol defined in the ACL rules. Create ACL and QoS policies prior to enabling this command. For CoPP, use the keyword cpu-qos when creating qos-policy-input. Related Commands ip access-list extended — creates an extended IP ACL. mac access-list extended — creates an extended MAC ACL. qos-policy-input — creates a QoS input policy map.
-------------Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q10 Q11 ----------1300 300 300 400 2000 300 400 400 400 600 300 300 ----------512 50 50 50 50 50 50 50 50 50 50 50 show ip protocol-queue-mapping Display the queue mapping for each configured protocol. Syntax show ip protocol-queue-mapping Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific.
Dell# Dell# Dell# show ipv6 protocol-queue-mapping Display the queue mapping for each configured IPv6 protocol. Syntax show ipv6 protocol-queue-mapping Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
Defaults Not configured. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.
12 Data Center Bridging (DCB) Data center bridging (DCB) refers to a set of IEEE Ethernet enhancements that provide data centers with a single, robust, converged network to support multiple traffic types, including local area network (LAN), server, and storage traffic. The Dell Networking operating software commands for data center bridging features include 802.1Qbb priority-based flow control (PFC), 802.1Qaz enhanced transmission selection (ETS), and the data center bridging exchange (DCBX) protocol.
Usage Information Version Description 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. By default, iSCSI is enabled on the unit and the flow control is enabled on all of the interfaces. It is also acts as defaults when the link-level flow control is enabled on one or more interfaces. Enables priority flow control or enhance transmission selection on interface.
pfc no-drop queues Configure the port queues that still function as no-drop queues for lossless traffic. Syntax pfc no-drop queues queue-range To remove the no-drop port queues, use the no pfc no-drop queues command. Parameters queue-range Enter the queue range. Separate the queue values with a comma; specify a priority range with a dash; for example, pfc no-drop queues 1,3 or pfc no-drop queues 7 or pfc no-drop queues 0,7. The range is from 0 to 3. Defaults No lossless queues are configured.
pfc priority Configure the CoS traffic to be stopped for the specified delay. Syntax pfc priority priority-range To delete the pfc priority configuration, use the no pfc priority command. Parameters priority-range Enter the 802.1p values of the frames to be paused. Separate the priority values with a comma; specify a priority range with a dash; for example, pfc priority 1,3,5-7. The range is from 0 to 7. Defaults none Command Modes DCB INPUT POLICY Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. Usage Information Specify a stack-unit number on the Master switch in a stack.
Field Description Admin mode is on Admin is enabled PFC admin mode is on or off with a list of the configured PFC priorities. When the PFC admin mode is on, PFC advertisements are enabled to be sent and received from peers; received PFC configuration take effect. The admin operational status for a DCBX exchange of PFC configuration is enabled or disabled.
Field Description PFC TLV Statistics: Output TLV pkts Number of PFC TLVs transmitted. PFC TLV Statistics: Error pkts Number of PFC error packets received. PFC TLV Statistics: Pause Tx pkts Number of PFC pause frames transmitted. PFC TLV Statistics: Pause Rx pkts Number of PFC pause frames received.
Parameters port-type Enter the port type. slot/port [/subport] Enter the slot/port number. Enter the subport number if a 40G port is fanned-out into 10G ports. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module.
show interface ets Displays the ETS configuration applied to egress traffic on an interface, including priority groups with priorities and bandwidth allocation. Syntax Parameters show interface port-type slot/port[/subport] ets {summary | detail} port-type slot/ port[/subport] ets Enter the port-type slot and port ETS information. Enter the subport number if a 40G port is fanned-out into 10G ports.
TC-grp Priority# Bandwidth TSA -----------------------------------------------0 1 0,1,2 100% ETS 2 3 0 % SP 3 4,5,6,7 0 % SP 4 5 6 7 Oper status is init ETS DCBX Oper status is Down State Machine Type is Asymmetric Conf TLV Tx Status is enabled Reco TLV Tx Status is enabled 0 Input Conf TLV Pkts, 1955 Output Conf TLV Pkts, 0 Error Conf TLV Pkts 0 Input Reco TLV Pkts, 1955 Output Reco TLV Pkts, 0 Error Reco TLV Pkts Dell# show int te 1/3/1 ets de Interface TenGigabitEthernet 1/3/1 Max Supported TC Groups is
Dell# show interfaces tengigabitethernet 1/1/1 ets detail Interface TenGigabitEthernet 1/1/1 Max Supported TC Groups is 4 Number of Traffic Classes is 8 Admin mode is on Admin Parameters : -----------------Admin is enabled TC-grp Priority# Bandwidth TSA 0 0,1,2,3,4,5,6,7 100% ETS 1 0% ETS 2 0% ETS 3 0% ETS 4 0% ETS 5 0% ETS 6 0% ETS 7 0% ETS Priority# Bandwidth TSA 0 13% ETS 1 13% ETS 2 13% ETS 3 13% ETS 4 12% ETS 5 12% ETS 6 12% ETS 7 12% ETS Remote Parameters: ------------------Remote is disabled Local Pa
TC-grp Priority# 0 0,1,2,3,4,5,6,7 1 2 3 4 5 6 7 Bandwidth 100% 0% 0% 0% 0% 0% 0% 0% TSA ETS ETS ETS ETS ETS ETS ETS ETS Priority# 0 1 2 3 4 5 6 7 Remote Parameters: ------------------Remote is disabled Bandwidth 13% 13% 13% 13% 12% 12% 12% 12% TSA ETS ETS ETS ETS ETS ETS ETS ETS Bandwidth 100% 0% 0% 0% 0% 0% 0% 0% TSA ETS ETS ETS ETS ETS ETS ETS ETS Local Parameters : -----------------Local is enabled TC-grp Priority# 0 0,1,2,3,4,5,6,7 1 2 3 4 5 6 7 Priority# Bandwidth TSA 0 13% ETS 1 13% ETS 2 13
advertise dcbx-tlv On a DCBX port with a manual role, configure the PFC and ETS TLVs advertised to DCBX peers. Syntax advertise dcbx-tlv {ets-conf | ets-reco | pfc} [ets-conf | ets-reco | pfc] [ets-conf | ets-reco | pfc] To remove the advertised ETS TLVs, use the no advertise dcbx-tlv command. Parameters {ets-conf | ets-reco | pfc} Enter the PFC and ETS TLVs advertised, where: • ets-conf: enables the advertisement of ETS configuration TLVs. • ets-reco: enables the advertisement of ETS recommend TLVs.
Parameters config-source | auto-downstream | auto-upstream | manual Enter the DCBX port role, where: • config-source: configures the port to serve as the configuration source on the switch. • auto-upstream: configures the port to receive a peer configuration. The configuration source is elected from auto-upstream ports. • auto-downstream: configures the port to accept the internally propagated DCB configuration from a configuration source.
Defaults Auto Command Modes INTERFACE PROTOCOL LLDP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module. fcoe priority-bits Configure the FCoE priority advertised for the FCoE protocol in application priority TLVs. Syntax fcoe priority-bits priority-bitmap To remove the configured FCoE priority, use the no fcoe priority-bits command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.16.0 Introduced on the MXL 10/40GbE Switch IO Module.
Field Description Port-Role Configured the DCBX port role: auto-upstream, auto-downstream, config-source, or manual. DCBX Operational Status Operational status (enabled or disabled) used to elect a configuration source and internally propagate a DCB configuration. The DCBX operational status is the combination of PFC and ETS operational status. Configuration Source Specifies whether the port serves as the DCBX configuration source on the switch: true (yes) or false (no).
Example Field Description Total DCBX Frame errors Number of DCBX frames with errors received. Total DCBX Frames unrecognized Number of unrecognizable DCBX frames received.
Parameters map-name Enter a DCB map name. The maximum number of alphanumeric characters is 32. Defaults None. There are no pre-configured PFC and ETS settings on S5000 Ethernet interfaces. Command Modes CONFIGURATION INTERFACE Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810 and S6000 platforms. A DCB map is a template used to configure DCB parameters and apply them on converged Ethernet interfaces.
Command Modes Command History Usage Information DCB MAP Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810, S6000 platforms. PFC and ETS settings are not pre-configured on Ethernet ports. You must use the dcb-map command to configure different groups of 802.1p priorities with PFC and ETS settings. Using the priority-pgid command, you assign each 802.1p priority to one priority group. A priority group consists of 802.
Usage Information Version Description 9.3(0.0) Introduced on the S4810, S6000 platforms. Use the dcb-map command to configure priority groups with PFC and/or ETS settings and apply them to Ethernet interfaces. Use the priority-pgid command to map 802.1p priorities to a priority group. You can assign each 802.1p priority to only one priority group. A priority group consists of 802.
Usage Information Version Description 9.3(0.0) Introduced on the S4810 and S6000 platforms. The dcb-map stack-unit all stack-ports all command overwrites any previous DCB maps applied to stack ports. dcb pfc-shared-buffer-size Configure the maximum amount of shared buffer size for PFC packets in kilobytes. You must configure the shared buffer size to be less than the total PFC buffer size.
dcb-buffer-threshold Configure the profile name for the DCB buffer threshold. This utility is supported on the S4810, S4820T, and S6000 platforms. Syntax dcb buffer—threshold profile-name Parameters profile-name Enter the name of the profile, which can be a string of up to 32 characters in length. Default None Command Modes CONFIGURATION mode Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810, S4820T, and S6000 platforms.
size Weightage of the priorities on the shared buffer size in the system. Enter a number in the range of 0 to 9. The default shared threshold weight is 10. Default The default size of the ingress buffer is 45 KB. The default buffer limit at which the port sends the pause to peer and recommences the sending of packets to the peer is 10 KB. The default threshold weight of the shared buffer space is 10. Command Modes DCB-BUFFER-THRESHOLD mode Command History Usage Information Version Description 9.
no-drop The packets for this queue must not be dropped value Enter a number in the range of 0 to 7 to denote the priority to be allocated to the dynamic buffer control mechanism buffer-size Ingress buffer size size Size of the ingress buffer in KB. Enter a number in the range of 0 to 7787. The default is 45 KB. pause-threshold Buffer limit for pause frames to be sent threshold-value Buffer limit at which the port sends the pause to peer in KB. Enter a number in the range of 0 to 7787.
Dell(conf-qos-policy-buffer)# queue 4 pause no-drop buffer-size 128000 pause-threshold 103360 resume-threshold 83520 dcb-policy buffer-threshold (Interface Configuration) Assign the DCB policy to the DCB buffer threshold profile on interfaces. This setting takes precedence over the global bufferthreshold setting.
Usage Information Example Version Description 9.3(0.0) Introduced on the S6000 platform.
history Y Command Modes Historical snapshot details of buffer space statistics, where Y can be one of the following: • Instance {all | id} - Displays the information for all instances or the specified instance of the snapshot. • Summary - Displays the consolidated information pertaining to the preceding three instances of the snapshot values collected in history. EXEC EXEC Privilege Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.
Stack-unit 1 unit 0 port 5 (interface te 1/4/1) -----------------------------------------------------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS Instance 1 Instance 2 Instance 3 Instance 4 Instan 10S 20S 30S 40S -----------------------------------------------------------------------------------UCAST 2 5 4 6 0 UCAST 3 2 0 1 5 UCAST 11 0 3 2 0 MCAST 4 0 0 0 0 If only two instances are available at the time the above show command is issued, only two instances is displayed in the su -------
UCAST UCAST UCAST UCAST UCAST UCAST UCAST UCAST UCAST UCAST UCAST UCAST MCAST MCAST MCAST MCAST MCAST MCAST MCAST MCAST MCAST 0 1 2 3 4 5 6 7 8 9 10 11 0 1 2 3 4 5 6 7 8 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 Stack-unit: 1 unit: 0 port: 5 (interface Fo 1/4) --------------------------------------PG# SHARED CELLS HEADROOM CELLS --------------------------------------0 0 0 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0 7 0 0 --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS ----------------------
5 6 7 0 0 0 0 0 0 --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------UCAST 0 0 UCAST 1 0 UCAST 2 0 UCAST 3 0 UCAST 4 0 UCAST 5 0 UCAST 6 0 UCAST 7 0 UCAST 8 0 UCAST 9 0 UCAST 10 0 UCAST 11 1 MCAST 0 0 MCAST 1 0 MCAST 2 0 MCAST 3 0 MCAST 4 0 MCAST 5 0 MCAST 6 0 MCAST 7 0 MCAST 8 0 To determine the port that is congested and monitor all queues (including multicast and unicast queues] only on that port Dell#$show hardware stack-unit 1 buffer-stats-sn
MCAST MCAST MCAST MCAST MCAST MCAST Dell# 3 4 5 6 7 8 0 0 0 0 0 0 To determine the port that is congested and monitor all the unicast Queues on that port: Dell#show hardware stack-unit 1 buffer-stats-snapshot unit 0 resource port 1 queue u Stack-unit: 1 unit: 0 port: 1 (interface Te 1/1) --------------------------------------Q# TYPE Q# TOTAL BUFFERED CELLS --------------------------------------UCAST 0 0 UCAST 1 0 UCAST 2 0 UCAST 3 0 UCAST 4 0 UCAST 5 0 UCAST 6 0 UCAST 7 0 UCAST 8 0 UCAST 9 0 UCAST 10 0
dcb pfc-total-buffer-size Configure the total buffer size for PFC in kilobytes. This utility is supported on the S6000 platform. Syntax dcb pfc-total—buffer—size KB Parameters KB Enter a number in the range of 0 to 7787. Default The default is 1 KB for S6000 platforms. Command Modes CONFIGURATION mode Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S6000 platform. Configure the maximum buffer available for PFC traffic.
Usage Information Example The following table describes the output fields displayed for the show running-config dcb-buffer-threshold Field Description Profile name Name of the DCB buffer threshold profile Priority The priority of the queue for which the buffer space s apply buffer-size Ingress buffer size pause-threshold-value Buffer limit at which the port sends the pause to peer resume-threshold-value Buffer offset limit at which the port resumes the peer Dell#show run buffer-threshold ! dcb
dcb pfc-queues Configure the number of PFC queues. This utility is supported on the and platforms. Syntax dcb pfc-queues value Parameters value Enter the number of PFC queues in the range of 0 through 4. The number of ports supported based on lossless queues configured will depend on the buffer. Default The default number of PFC queues in the system is 2 for S4810 and 1 for S6000 platforms. Command Modes CONFIGURATION mode Command History Version Description 9.7(0.0) Introduced on the S6000-ON.
• “pfc priority” CLI is mutually exclusive to “no dcb pfc enable” command. • Deprecated CLI “dcb-policy input” and “no dcb pfc enable” cannot coexist at interface level. • Deprecated CLI “dcb-policy output” and “no dcb ets enable” cannot coexist at interface level.
13 Debugging and Diagnostics The basic debugging and diagnostic commands are supported by the Dell Networking Operating System. This chapter contains the following sections: • Diagnostic and Monitoring Commands • Offline Diagnostic Commands • Hardware Commands Diagnostics and Monitoring Commands The following section describes the diagnostics and monitoring commands. For similar commands, refer to the Control and Monitoring chapter. logging coredump stack-unit Enable coredump on a stack.
Offline Diagnostic Commands The offline diagnostics test suite is useful for isolating faults and debugging hardware. While tests are running, Dell Networking OS results are saved as a text file (TestReport-SU-X.txt) in the flash directory. This show file command is available only on master and standby. Important Points to Remember • Offline diagnostics can only be run when the unit is offline. • You can only run offline diagnostics on a unit to which you are connected via the console.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced the verbose option. 7.7.1.
Warning - Diagnostic execution will cause stack-unit to reboot after completion of diags. Proceed with Offline-Diags [confirm yes/no]:y online stack-unit Place a stack unit in the online state. Syntax Parameters online stack-unit number number Enter the stack-unit number. The range is from 1 to 6. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
Hardware Commands These commands display information from a hardware sub-component or ASIC. clear hardware stack-unit Clear statistics from selected hardware components.
clear hardware system-flow Clear system-flow statistics from selected hardware components. Syntax Parameters clear hardware system-flow layer2 stack-unit number port-set 0–0 counters stack-unit number Enter the keywords stack-unit then a number to select a particular stack member and then enter one of the following command options to clear a specific collection of data. The range is from 1 to 6.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced this command. hardware watchdog To trigger a reboot and restart the system, set the watchdog timer. Syntax hardware watchdog stack-unit {<0-5> | all} Defaults Enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. The unit numbers given are internal port numbers. show hardware layer3 Display Layer 3 ACL or QoS data for the selected stack member and stack member port-pipe.
party-bus statistics | stack-port | ti-monitor | unit 0-1 {counters | details | port-stats [detail] | register}} Parameters stack-unit stackunit {commandoption} Enter the keywords stack-unit to select a particular stack member and then enter one of the following command options to display a collection of data based on the option entered. The range is from 1 to 6. buffer Enter the keyword buffer. To display the total buffer statistics for the stack unit, enter the keyword total-buffer.
Example (DataPlane) Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(0.2) Modified the drops keyword range, unit keyword range and added the buffer and cpu management statistics options. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.5 Added i2c statistics and sata-interfaces statistics. 8.3.11.4 Added user port information. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series.
0 0 0 Dell# 0 0 0 Example (Drops Unit, Port) Dell#show hardware stack-unit 1 drops unit 1 port 27 --- Ingress Drops --Ingress Drops : 0 IBP CBP Full Drops : 0 PortSTPnotFwd Drops : 0 IPv4 L3 Discards : 0 Policy Discards : 0 Packets dropped by FP : 0 (L2+L3) Drops : 0 Port bitmap zero Drops : 0 Rx VLAN Drops : 0 --- Ingress MAC counters--Ingress FCSDrops : 0 Ingress MTUExceeds : 0 --- MMU Drops --HOL DROPS : 0 TxPurge CellErr : 0 Aged Drops : 0 --- Egress MAC counters--Egress FCS Drops : 0 --- Egress FORW
0 Dell# Example (Register) Dell#show hardware stack-unit 1 unit 1 register 0x0068003c AGINGCTRMEMDEBUG.mmu0 = 0x00000000 0x0068003d AGINGEXPMEMDEBUG.mmu0 = 0x00000000 0x00680017 ASFCONFIG.mmu0 = 0x0000000e 0x0060004c ASFPORTSPEED.ge0 = 0x00000000 0x0060104c ASFPORTSPEED.ge1 = 0x00000000 0x0060204c ASFPORTSPEED.ge2 = 0x00000000 0x0060304c ASFPORTSPEED.ge3 = 0x00000000 0x0060404c ASFPORTSPEED.ge4 = 0x00000000 0x0060504c ASFPORTSPEED.ge5 = 0x00000000 0x0060604c ASFPORTSPEED.
0x0b702001 BCAST_STORM_CONTROL.ge2 = 0x00000000 0x0b703001 BCAST_STORM_CONTROL.ge3 = 0x00000000 0x0b704001 BCAST_STORM_CONTROL.ge4 = 0x00000000 0x0b705001 BCAST_STORM_CONTROL.ge5 = 0x00000000 0x0b706001 BCAST_STORM_CONTROL.ge6 = 0x00000000 0x0b707001 BCAST_STORM_CONTROL.ge7 = 0x00000000 0x0b708001 BCAST_STORM_CONTROL.ge8 = 0x00000000 0x0b709001 BCAST_STORM_CONTROL.ge9 = 0x00000000 0x0b70a001 BCAST_STORM_CONTROL.
Example (TotalBuffer) Dell#show hardware stack-unit 1 buffer total-buffer Example (BufferInfo) Dell# show hardware stack-unit 1 buffer unit 0 port 1 buffer-info ----- Buffer Stats for Unit 1 Port 1 ----Maximum Shared Limit for the Port: 30720 Default Packet Buffer allocate for the Port: 120 Dell#show hardware stack-unit 1 buffer total-buffer ----- Buffer Details for Stack-Unit 1 ----Total Buffers allocated per Stack-Unit 46080 Used Packet Buffer for the Port: 0 Example (Queue2/ Buffer-Info) Dell#show
Command History Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. Version 9.3(0.0) Introduced on the S6000 platform. The following table describes the fields in the output of the show command: Field Description Buffer Accounting Stats for Unit 0 Port 1 prioritygroup 0 Displays the counters that are calculated by the buffer statistics tracking method for each port per priority group on a particular stack member.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
meter=NULL, counter={idx=2, mode=0x01, entries=1} ################# FP Entry for redirecting GVRP traffic to RSM ########### EID 2044: gid=1, slice=15, slice_idx=0x03, prio=0x7fc, flags=0x82, Installed tcam: color_indep=0, higig=0, higig_mask=0, KEY=0x00000000 00000000 00000000 0180c200 00210000 00000000 00000000 , FPF4=0x00 MASK=0x00000000 00000000 00000000 ffffffff ffff0000 00000000 00000000 , 0x00 action={act=Drop, param0=0(0x00), param1=0(0x00)}, action={act=CosQCpuNew, param0=7(0x07), param1=0(0x00)},
Total number of outbytes: Dell# Related Commands 0 clear hardware system-flow — clears the statistics from selected hardware components. show hardware stack-unit buffer-stats-snapshot View the buffer statistics tracking resource information without polling details and historical snapshots. This command is supported on the S6000 platform.
When the buffer-stats-snapshot is disabled, an informational message is dispayed to this effect when you attempt to view the buffer statistics tracking resource information without polling details and historical snapshots.
show hardware stack-unit buffer-stats-snapshot (Total Buffer Information) View the buffer statistics tracking resource information depending on the type of buffer information, such as device-level details, port-level counters, queue-based snapshots, or priority group-level snapshot in the egress and ingress direction of traffic. This command is supported on the S6000 platform.
• Port-egress – Displays the total unicast buffer usage, total multicast buffer usage separately for the egress port. • Port-Queue ucast/mcast – Displays the total unicast/multicast buffer usage on per-port per-queue basis. For CPU port, counters for queues 0 – 11 will be displayed and there is no differentiation between unicast and multicast queues. • Port- Priority-Group – Displays the shared space usage counters usage, head-room space counters per ingress port on per-priority-group granularity.
14 Dynamic Host Configuration Protocol (DHCP) Dynamic host configuration protocol (DHCP) is an application layer protocol that dynamically assigns IP addresses and other configuration parameters to network end-stations (hosts) based on the configuration policies the network administrators determine. The Dell Networking operating system supports the basic DHCP commands on the platform.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. Entering after the clear ip dhcp binding command clears all the IPs from the binding table. debug ip dhcp server Display FTOS debugging messages for DHCP. Syntax debug ip dhcp server [events | packets] Parameters events Enter the keyword events to display the DHCP state changes.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. default-router Assign a default gateway to clients based on the address pool. Syntax Parameters default-router address [address2...address8] address Enter a list of routers that may be the default gateway for clients on the subnet. You may specify up to eight routers. List them in order of preference.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series.
Parameters name Give a name to the group of addresses in a pool. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
hardware-address For manual configurations, specify the client hardware address. Syntax hardware-address address Parameters address Enter the hardware address of the client. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. lease Specify a lease time for the addresses in a pool. Syntax Parameters lease {days [hours] [minutes] | infinite} days Enter the number of days of the lease. The range is from 0 to 31. hours Enter the number of hours of the lease. The range is from 0 to 23. minutes Enter the number of minutes of the lease. The range is from 0 to 59.
Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
network Specify the range of addresses in an address pool. Syntax network network /prefix-length Parameters network/ prefixlength Specify a range of addresses. Prefix-length range is from 17 to 31. Defaults none Command Modes DHCP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. show ip dhcp binding Display the DHCP binding table. Syntax show ip dhcp binding Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. show ip dhcp conflict Display the address conflict log. Syntax Parameters show ip dhcp conflict address address Display a particular conflict log entry. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series and S-Series. Commands to Configure Secure DHCP DHCP, as defined by RFC 2131, provides no authentication or security mechanisms. Secure DHCP is a suite of features that protects networks that use dynamic address allocation from spoofing and attacks.
Defaults Command Modes Command History Disabled • INTERFACE • INTERFACE PORT-CHANNEL This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Added the keywords discard-counters, interface, and the variable interface on the S4810, S4820T, S5000, S6000, Z9000, Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.
ip dhcp relay Enable Option 82. Syntax ip dhcp relay information-option [remote-id | trust-downstream] Parameters remote-id Configure the system to enable the remote-id string in option-82. trust-downstream Configure the system to trust Option 82 when it is received from the previous-hop router. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Usage Information Version Description 8.3.1.0 Introduced on the E-Series. 8.2.1.0 Introduced on the C-Series and S-Series on Layer 2 interfaces. 7.8.1.0 Introduced on the C-Series and S-Series on Layer 3 interfaces. When enabled, no learning takes place until you enable snooping on a VLAN. After disabling DHCP snooping, the binding table deletes and Option 82, IP Source Guard, and Dynamic ARP Inspection are disabled. Introduced in Dell Networking OS version 7.8.1.
Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp snooping binding Create a static entry in the DHCP binding table. Syntax Parameters Defaults Command Modes Command History [no] ip dhcp snooping binding mac address vlan-id vlan-id ip ip-address interface type slot/port[/subport] lease number mac address Enter the keyword mac then the MAC address of the host to which the server is leasing the IP address.
Related Commands Version Description 8.3.1.0 Introduced on the E-Series. 7.8.1.0 Introduced on the C-Series and S-Series. show ip dhcp snooping — displays the contents of the DHCP binding table. IPv6 DHCP Snooping Binding Create a static DHCP snooping binding entry in the snooping database.
ip dhcp snooping database Delay writing the binding table for a specified time. Syntax Parameters ip dhcp snooping database write-delay minutes minutes The range is from 5 to 21600. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.
Version Description 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. ip dhcp snooping database renew Renew the binding table. Syntax ip dhcp snooping database renew Defaults none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
ip dhcp snooping trust Configure an interface as trusted. Syntax [no] ip dhcp snooping trust Defaults Untrusted Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
vlan vlan-id Defaults Disabled Command Modes INTERFACE (OPTIONAL) SAV validates the source IP address along with the source VLAN ID against the DHCP snooping binding table. INTERFACE PORTCHANNEL Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
NOTE: Adds the VPN/VRF related sub-options into the relay agent information option(82). When DHCP broadcasts are forwarded by the relay agent from clients to DHCP server. Default Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.
Version Description 8.3.1.0 Introduced on the E-Series. 7.2.1.0 Introduced on the C-Series and S-Series. ipv6 dhcp snooping verify mac-address Configure to enable verify source mac-address against ipv6 DHCP packet mac address. Syntax [no] ipv6 dhcp snooping verify mac-address To disable verify source mac-address against ipv6 DHCP packet mac address, use the no ipv6 dhcp snooping verify mac-address command.
Example Dell(conf-if-fo-1/12)#ip helper-address vrf jay 10.0.0.2 ipv6 helper-address Configures the ipv6 DHCP helper addresses without VRF. Syntax [no] ipv6 helper-address ipv6-address To delete the ipv6 helper address, use the [no] ipv6 helper-address ipv6-address command. Parameters ipv6-address Enter the keywordipv6–address through which the server address can be reached. Default Disabled. Command Modes INTERFACE Command History This guide is platform-specific.
Enter any of the following keywords and slot/port[/subport] or number information: Defaults • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
ipmac-vlan sav access-list on Port-channel 10 on stack-unit 2 Total cam count 5 permit host 0.0.0.0 host 00:00:00:00:00:00 count (0 packets) permit vlan 10 host 1.1.1.1 host 00:00:00:00:01:01 count (0 packets) permit vlan 10 host 1.1.1.2 host 00:00:00:00:01:02 count (0 packets) permit vlan 10 host 1.1.1.3 host 00:00:00:00:01:03 count (0 packets) ipmac-vlan sav access-list on Port-channel 10 on stack-unit 3 Total cam count 5 permit host 0.0.0.0 host 00:00:00:00:00:00 count (0 packets) permit vlan 10 host 1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description Version 9.7(0.0) Introduced on the S4810, S4820T, S6000 and Z-Series. Dell#show ipv6 dhcp snooping IPv6 DHCP Snooping IPv6 DHCP Snooping Mac Verification : Enabled. : Disabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S-Series and Z-Series. Usage Information Use this command to associate name server IP addresses to a specific VRF. Example • Dell(conf)#ip name-server vrf jay 2.2.2.
ip domain-list Adds a domain name to the DNS list. This domain name is appended to incomplete host names in DNS requests corresponding to a specific VRF. Syntax ip domain-list [vrf vrf-name] name To remove a domain name from DNS list, use the no ip domain-list [vrf vrf-name] name command. Parameters vrf vrf-name (Optional) Enter the key word vrf and then the name of the VRF to add a domain name to the DNS list corresponding to that VRF.
ip-address Enter the IP address of the name server in dotted decimal format. Defaults None Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S-Series and Z-Series.
15 Equal Cost Multi-Path (ECMP) Equal cost multi-path (ECMP) is supported on the Dell Networking OS. ecmp-group Provides a mechanism to monitor traffic distribution on an ECMP link bundle. A system log is generated when the standard deviation of traffic distribution on a member link exceeds a defined threshold. Syntax ecmp-group {ecmp-group-id interface interface | link-bundle-monitor} To remove the selected interface, use the ecmp-group no interface command.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. Using CONFIGURATION mode, create an ECMP group ID. You can then assign interfaces to the ECMP group using CONFIGURATION ECMP-GROUP mode. You can also enable on the port-channel configuration using the CONFIGURATION ECMP-GROUP command mode. hash-algorithm Changes the hash algorithm used to distribute traffic flows across a Port Channel. The ECMP and LAG options are supported on the Z-Series.
hg {crc16 | crc16cc | crc32MSB | crc32LSB | xor1 | xor2 | xor4 | xor8 | xor16} stack-unit stack-unit-number | port-set port-pipe • xor8: Use CRC16_BISYNC_AND_XOR8 — Upper 8 bits of CRC16-BISYNC and lower 8 bits of xor8 • xor16: Use CR16 — 16 bit XOR Z-Series only: Enter the keyword hg then one of the following options: • crc16: Use CRC16_BISYNC — 16 bit CRC16-bisync polynomial (default) • crc16cc: Use CRC16_CCITT — 16 bit CRC16 using CRC16-CCITT polynomial • crc32MSB: Use CRC32_UPPER — MSB 16 bits
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. 8.1.1.
ip ecmp-group Enable and specify the maximum number of ecmp that the L3 CAM hold for a route, By default, when maximum paths are not configured, the CAM can hold a maximum of 16 ecmp per route. Syntax ip ecmp-group {maximum-paths | {number} {path-fallback} To negate a command, use the no ip ecmp-group maximum-paths {number} command. Parameters maximum-paths Specify the maximum number of ECMP for a route. The range is 2 to 64. path-fallback Use the keywords path-fallback to enable this feature.
Example Dell(conf)#ip ecmp ? weighted Enables Weighted ECMP Dell(conf)#ip ecmp weighted Dell(conf)#do show running-config | grep ecmp ip ecmp weighted Dell(conf)# Dell(conf)#no ip ecmp ? weighted Disables Weighted ECMP Dell(conf)#no ip ecmp weighted Dell(conf)#do show running-config | grep ecmp link-bundle-distribution trigger-threshold Provides a mechanism to set the threshold to trigger when traffic distribution begins being monitored on an ECMP link bundle.
Command Modes Command History • ECMP-GROUP • PORT-CHANNEL INTERFACE This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. 500 Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.10.
16 Flex Hash and Optimized Boot-Up This chapter describes the Flex Hash and fast-boot enhancements. load-balance ingress-port enable Enable the Flex hash functionality. This utility is supported on the platform. Syntax load-balance ingress-port enable To disable the Flex hash capability, use the no version of this command. Default None Command Modes CONFIGURATION mode Command History Usage Information Version 9.3(0.0) Introduced on the S6000 platform.
Parameters ipv4 Denotes whether Flex Hash needs to be enabled for IPv4 packets. ipv6 Denotes whether Flex Hash needs to be enabled for IPv6 packets. protocol number Represents the Outer IPv4 protocol field in case of IPv4 packets, and the Outer IPv6 next header field in case of IPv6 packets. The ipv4/ipv6 keyword and the IP protocol value are used as keys to identify if a duplicate flex hash configuration is already present. Duplicate flex hash configuration is not possible.
reload-type fastboot Restart the system with optimized booting-time functionality enabled. When you restart the device in fast boot mode, traffic disruption is reduced significantly and the system operations to service the data traffic are restored in a seamless way. C9000 Series Syntax Parameters reload-type fastboot fastboot Enable the system to restart the next time with the optimized booting-time capability Defaults By default, the device reloads in Jumpstart or BMP mode.
Usage Information Version Description 9.3(0.0) Introduced on the S6000. You can configure the optimal switchover functionality for LACP even if you do not enable the fast boot mode on the system. You must configure the long timeout mechanism for the LACP session to enable the fast boot capability to operate properly. This command applies to dynamic port-channel interfaces only.
17 FCoE Transit To enable the FCoE Transit feature and configure FIP snooping, use the following Dell Networking Operating System commands on the platform. In a converged Ethernet network, a switch can operate as an intermediate Ethernet bridge to snoop on FIP packets during the login process on Fibre Channel over Ethernet (FCoE) forwarders (FCFs).
clear fip-snooping statistics Clears the statistics on the FIP packets snooped on all VLANs, a specified VLAN, or a specified port interface. Syntax clear fip-snooping statistics [interface vlan vlan-id | interface fortyGigEport-type port/slot[/subport] | interface port-channel portchannel-number] Parameters vlan-id Enter the VLAN ID of the FIP packet statistics to be cleared. port-type port/slot Enter the port-type and slot number of the FIP packet statistics to be cleared.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. debug fip snooping rx Enable debugging for FIP snooping receive-specific packets.
Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 9.2(0.2) Introduced on the S4810 and S4820T. Added the receive parameters packettype and interfaces and their options. feature fip-snooping Enable FCoE transit and FIP snooping on a switch. Syntax feature fip-snooping To disable the FCoE transit feature, use the no feature fip-snooping command. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. The maximum number of FCFs supported per FIP snooping-enabled VLAN is four.
fip-snooping max-sessions-per-enodemac Configure the maximum session limit per ENode MAC address. Syntax fip-snooping max—sessions—per—enode—mac max-sessions-value To return the configured maximum sessions to the default value, use the no fip-snooping max— sessions—per—enode—mac command. Parameters max-sessions-value Enter the maximum number of sessions allowed per ENode MAC address. The range is from 1 to 64.
fip-snooping port-mode fcoe-trusted Configure the port for bridge-to-bridge links. Syntax fip-snooping port-mode fcoe-trusted To remove the bridge-to-bridge link configuration from the port, use the no fip-snooping port-mode fcoe-trusted command. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Example Dell# show fip-snooping config FIP Snooping Feature enabled Status: Enabled FIP Snooping Global enabled Status: Enabled Global FC-MAP Value: 0X0EFC00 FIP Snooping enabled VLANs VLAN Enabled FC-MAP ----------------100 TRUE 0X0EFC00 show fip-snooping enode Display information on the ENodes in FIP-snooped sessions, including the ENode interface and MAC address, FCF MAC address, VLAN ID and FC-ID.
--------- --------------- ------- ---- ----d4:ae:52:1b:e3:cd Te 1/11/1 54:7f:ee:37:34:40 100 62:00:11 show fip-snooping fcf Display information on the FCFs in FIP-snooped sessions, including the FCF interface and MAC address, FCF interface, VLAN ID, FC-MAP value, FKA advertisement period, and number of ENodes connected. Syntax Parameters Command Modes Command History show fip-snooping fcf [fcf-mac-address] fcf-mac-address • EXEC • EXEC Privilege Enter the MAC address of the FCF to display.
show fip-snooping statistics Display statistics on the FIP packets snooped on all interfaces, including VLANs, physical ports, and port channels. Syntax show fip-snooping statistics [interface vlan vlan-id | interface port-type port/slot[/subport] | interface port-channel port-channel-number] Parameters Command Modes Command History vlan-id Enter the VLAN ID of the FIP packet statistics displays.
Example Field Description Number of VN Port Keep Alives Number of FIP-snoop VN port (Virtual N-port) keep-alive frames received on the interface Number of Multicast Discovery Advertisements Number of FIP-snoop multicast discovery advertisements received on the interface. Number of Unicast Discovery Advertisements Number of FIP-snoop unicast discovery advertisements received on the interface. Number of FLOGI Accepts Number of FIP FLOGI accept frames received on the interface.
Number of Session failures due to Hardware Config :0 Dell(conf)# Dell# show fip-snooping statistics int tengigabitethernet 1/11/1 Number of Vlan Requests :1 Number of Vlan Notifications :0 Number of Multicast Discovery Solicits :1 Number of Unicast Discovery Solicits :0 Number of FLOGI :1 Number of FDISC :16 Number of FLOGO :0 Number of Enode Keep Alive :4416 Number of VN Port Keep Alive :3136 Number of Multicast Discovery Advertisement :0 Number of Unicast Discovery Advertisement :0 Number of FLOGI Accepts
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the Z9500 and S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
show fips status Display the FIPs status on the platform. Syntax show fips status Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. 518 FCoE Transit Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.12.
18 Force10 Resilient Ring Protocol (FRRP) Force10 resilient ring protocol (FRRP) is supported on Dell Networking OS. FRRP is a proprietary protocol for that offers fast convergence in a Layer 2 network without having to run the spanning tree protocol (STP). The resilient ring protocol is an efficient protocol that transmits a high-speed token across a ring to verify the link status. All the intelligence is contained in the master node with practically no intelligence required of the transit mode.
Usage Information Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series. 7.5.1.0 Introduced. Executing this command without the optional ring-id command clears the statistics counters on all the available rings. Dell Networking OS requires a command line confirmation before the command executes.
Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Version Description 8.2.1.0 Introduced on the C-Series. 7.4.1.0 Introduced. disable Disable the resilient ring protocol. Syntax disable To enable the Resilient Ring Protocol, use the no disable command. Defaults Disabled Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Parameters primary interface secondary interface control-vlan vlan-id Enter the keyword primary to configure the primary interface then one of the following interfaces and slot/port[/subport] information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a port channel interface, enter the keywords port-channel then a number.
member-vlan Specify the member VLAN identification numbers. Syntax member-vlan {vlan-range} To return to the default, use the no member-vlan [vlan-range] command. Parameters vlan-range Enter the member VLANs using VLAN IDs (separated by commas), a range of VLAN IDs (separated by a hyphen), a single VLAN ID, or a combination. For example: VLAN IDs (comma-separated): 3, 4, 6. Range (hyphen-separated): 5-10. Combination: 3, 4, 5-10, 8.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series. 7.4.1.
Usage Information This command places you into the resilient ring protocol. After executing this command, the command line prompt changes to conf-frrp. show frrp Display the resilient ring protocol configuration. Syntax show frrp [ring-id [summary]] | [summary] Parameters ring-id Enter the ring identification number. The range is from 1 to 255 summary (OPTIONAL) Enter the keyword summary to view just a summarized version of the Ring configuration.
• The number of state change counters Example (Summary) Dell#show frrp summary Ring-ID State Mode Ctrl_Vlan Member_Vlans ---------------------------------------------2 UP Master 2 11-20, 25,27-30 31 UP Transit 31 40-41 50 Down Transit 50 32 Dell# Example (1) Dell#show frrp 1 Ring protocol 1 is in Master mode Ring Protocol Interface: Primary : TenGigabitEthernet 1/16/1 State: Forwarding Secondary: Port-channel 100 State: Blocking Control Vlan: 1 Ring protocol Timers: Hello-Interval 50 msec Dead-Interval 1
NOTE: The configured dead interval must be at least three times the hello interval. Defaults • 500 ms for hello-interval milliseconds • 1500 ms for dead-intervalmilliseconds Command Modes CONFIGURATION (conf-frrp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
19 GARP VLAN Registration (GVRP) The Dell Networking operating system supports the basic GVRP commands on the Dell Networking OS. The generic attribute registration protocol (GARP) mechanism allows the configuration of a GARP participant to propagate through a network quickly. A GARP participant registers or de-registers its attributes with other participants by making or withdrawing declarations of attributes.
clear gvrp statistics Clear GVRP statistics on an interface. Syntax clear gvrp statistics interface interface Parameters interface interface Enter the following keywords and slot/port[/subport] or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
To disable debugging, use the no debug gvrp {config | events | pdu} command. Parameters config Enter the keyword config to enable debugging on the GVRP configuration. event Enter the keyword event to enable debugging on the JOIN/LEAVE events. pdu Enter the keyword pdu then one of the following Interface keywords and slot/ port[/subport] or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series gvrp enable — enables GVRP on physical interfaces and LAGs. protocol gvrp — access GVRP protocol.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series disable — globally disables GVRP. gvrp registration Configure the GVRP register type. Syntax gvrp registration {fixed | normal | forbidden} To return to the default, use the gvrp register normal command.
Usage Information Fixed registration prevents an interface, configured using the command line, to belong to a VLAN (static configuration) from being unconfigured when it receives a Leave message. Therefore, Registration mode on that interface is fixed. Normal registration is the default registration. The port’s membership in the VLAN depends on GVRP. The interface becomes a member of a VLAN after learning about the VLAN through GVRP.
show config Display the global GVRP configuration. Syntax show config Command Modes CONFIGURATION-GVRP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series Example Dell#show garp timers GARP Timers Value (milliseconds) ---------------------------------------Join Timer 200 Leave Timer 600 LeaveAll Timer 10000 Dell# Related Commands garp timers — sets the intervals (in milliseconds) for sending GARP messages.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on C-Series, E-Series, and S-Series Usage Information If no ports are GVRP participants, the message output changes from GVRP Participants running on to GVRP Participants running on no ports. Example R3#show gvrp brief GVRP Feature is currently enabled.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 7.6.1.
20 ICMP Message Types This chapter lists and describes the possible ICMP message type resulting from a ping. The first three columns list the possible symbol or type/code. For example, you would receive a ! or 03 as an echo reply from your ping. ICMP Messages and Their Definitions. Symbol Type Code . 0 U 3 4 3 Error ICMP Message Types echo reply . destination unreachable: 0 network unreachable . 1 host unreachable . 2 protocol unreachable . 3 port unreachable .
Symbol & Type Code Description Query 8 0 echo request . 9 0 router advertisement . 10 0 router solicitation . 11 Error time exceeded: 0 time-to-live equals 0 during transit . 1 time-to-live equals 0 during reassembly . 12 parameter problem: 1 IP header bad (catchall error) . 2 required option missing . 13 0 timestamp request . 14 0 timestamp reply . 15 0 information request (obsolete) . 16 0 information reply (obsolete) . 17 0 address mask request .
21 Internet Group Management Protocol (IGMP) The IGMP commands are supported by the Dell Networking operating software on the Dell Networking OS. This chapter contains the following sections: • IGMP Commands • IGMP Snooping Commands IGMP Commands Dell Networking OS supports IGMPv1/v2/v3 and is compliant with RFC-3376.
• For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF.
• For a port channel interface, enter the keywords port-channel then a number. Defaults Disabled. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. 7.6.1.0 Introduced on E-Series. The access list accepted is an extended ACL. To block IGMP reports from hosts, on a per-interface basis based on the group address and source address that you specify in the access list, use this feature. ip igmp immediate-leave Enable IGMP immediate leave.
ip igmp last-member-query-interval Change the last member query interval, which is the Max Response Time inserted into Group-Specific Queries sent in response to Leave Group messages. This interval is also the interval between Group-Specific Query messages. Syntax ip igmp last-member-query-interval milliseconds To return to the default value, use the no ip igmp last-member-query-interval command. Parameters milliseconds Enter the number of milliseconds as the interval.
Parameters seconds Enter the number of seconds between queries sent out. The range is from 1 to 18000. The default is 60 seconds. Defaults 60 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Defaults 10 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description Version 9.7(0.0) Added support for VRF and Introduced on the S6000-ON. Version 9.5(0.0) Introduced on the Z9500. Version 9.0.2.0 Introduced on the S6000. Version 8.3.19.0 Introduced on the S4820T. Version 8.3.11.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.7.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series. show ip igmp groups View the IGMP groups. Syntax show ip igmp [vrf vrf-name] groups [group-address [detail] | detail | interface [group-address [detail]]] Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series and C-Series. 7.5.1.0 Expanded to support the detail option. E-Series legacy command. Usage Information This command displays the IGMP database, including configured entries for either all groups on all interfaces, all groups on specific interfaces, or specific groups on specific interfaces.
Example (Details) Dell#show ip igmp group details Interface Vlan 20 Group 232.1.1.5 Uptime 00:11:22 Expires Never Router mode INCLUDE Last reporter 35.0.0.2 Group source list Source address Expires 65.0.0.1 00:01:22 65.0.0.2 00:01:22 65.0.0.3 00:01:22 65.0.0.4 00:01:22 65.0.0.5 00:01:22 show ip igmp interface View information on the interfaces participating in IGMP.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command. Usage Information IGMP commands accept only non-VLAN interfaces — specifying VLAN does not yield results. The show ip igmp interface command does not display information corresponding to the loop-back interfaces.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. 7.7.1.0 Introduced on the E-Series. Example Dell#show ip igmp ssm-map Interface Vlan 20 Group 232.1.1.
Important Points to Remember for IGMP Querier • The IGMP snooping Querier supports version 2. • You must configure an IP address to the VLAN interface for IGMP snooping Querier to begin. The IGMP snooping Querier disables itself when a VLAN IP address is cleared, and then it restarts itself when an IP address is reassigned to the VLAN interface. • When enabled, IGMP snooping Querier does not start if there is a statically configured multicast router interface in the VLAN.
Parameters • To disable debugging of IGMP snooping, use the no debug ip igmp snooping [group address | interface] command. • To disable all debugging, use the undebug all command. snooping Enter the keyword snooping to enable debugging of IGMP snooping. group-address (OPTIONAL) Enter the IP multicast group address in dotted decimal format.
Usage Information Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. To enable IGMP snooping, enter this command.
Version Description E-Series legacy command. Usage Information Queriers normally send some queries when a leave message is received prior to deleting a group from the membership database. There may be situations when you require a fast deletion of a group. When you enable IGMP fast leave processing, the switch removes an interface from the multicast group as soon as it detects an IGMP version 2 leave message on the interface.
ip igmp snooping mrouter Statically configure a VLAN member port as a multicast router interface. Syntax ip igmp snooping mrouter interface interface To delete a specific multicast router interface, use the no igmp snooping mrouter interface interface command. Parameters interface interface Enter the following keywords and slot/port[/subport] or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
ip igmp snooping querier Enable IGMP querier processing for the VLAN interface. Syntax ip igmp snooping querier To disable IGMP querier processing for the VLAN interface, use the no ip igmp snooping querier command. Defaults Not configured. Command Modes INTERFACE VLAN — (conf-if-vl-n) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
detail Command Modes Command History • EXEC • EXEC Privilege • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number.
show ip igmp snooping mrouter Display multicast router interfaces. Syntax show ip igmp snooping mrouter [vlan number] Parameters Command Modes Command History vlan number • EXEC • EXEC Privilege Enter the keyword vlan then the vlan number. The range is from 1 to 4094. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
22 Interfaces The commands in this chapter are supported by Dell Networking operating software on the platform. This chapter contains the following sections: • Basic Interface Commands • Port Channel Commands • Time Domain Reflectometer (TDR) • UDP Broadcast Basic Interface Commands The following commands are for Physical, Loopback, and Null interfaces.
vrrp [[ipv6] vrid] (OPTIONAL) Enter the keyword vrrp to clear the counters of all VRRP groups. To clear the counters of VRRP groups on all IPv6 interfaces, enter ipv6. To clear the counters of a specified group, enter a VRID number from 1 to 255. learning-limit (OPTIONAL) Enter the keywords learning-limit to clear unknown source address (SA) drop counters when MAC learning limit is configured on the interface. vlan vlan-id Enter the keyword vlan followed by the interface VLAN number.
Parameters interface (OPTIONAL) Enter any of the following keywords and slot/port[/subport] or number to clear counters from a specified interface: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Parameters half-life Enter the number of seconds after which the penalty is decreased. The penalty decreases half after the half-life period expires. The range is from 1 to 30 seconds. The default is 5 seconds. reuse-threshold Enter a number as the reuse threshold, the penalty value below which the interface state is changed to “up”. The range is from 1 to 20000. The default is 750.
show interfaces dampening — displays interface dampening information. description Assign a descriptive text string to the interface. Syntax description desc_text To delete a description, use the no description command. Parameters desc_text Enter a text string up to 240 characters long. Defaults none Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
duplex (10/100 Interfaces) Configure duplex mode on any physical interfaces where the speed is set to 10/100. Syntax duplex {half | full} To return to the default setting, use the no duplex command. Parameters half Enter the keyword half to set the physical interface to transmit only in one direction. full Enter the keyword full to set the physical interface to transmit in both directions. Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific.
The threshold commands are supported on S6000 only. To return to the default, use the no flowcontrol rx {off | on}tx {off on} threshold command. Parameters rx on Enter the keywords rx on to process the received flow control frames on this port. rx off Enter the keywords rx off to ignore the received flow control frames on this port. tx on Enter the keywords tx on to send control frames from this port to the connected device when a higher rate of traffic is received.
Can’t configure half duplex when flowcontrol is on, config ignored NOTE: The flow control must be off (rx off tx off) before configuring the half duplex. • Speeds less than 1 Gig cannot be configured when the asymmetric flow control configuration is on. The following erro returned: Can’t configure speed <1G when Asymmetric flowcontrol is on, config ignored • Dell Networking OS only supports rx on tx on and rx off tx off for speeds less than 1 Gig (Symmetric).
off on on Related Commands off on on off on on off on on show running-config — displays the flow configuration parameters (non-default values only). show interfaces — displays the negotiated flow control parameters. interface Configure a physical interface on the switch. Syntax Parameters interface interface range interface range Enter one of the following keywords and slot/port[/subport] or number information: • For a null interface, enter the keyword null then the slot/port information.
Usage Information Version Description 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Introduced You cannot delete a physical interface. By default, physical interfaces are disabled (shutdown) and are not assigned to an IP address or switchport.
Enter the member VLANs using VLAN IDs (separated by commas), a range of VLAN IDs (separated by a hyphen), a single VLAN ID, or a combination. For example: VLAN IDs (comma-separated): 3, 4, 6. Range (hyphen-separated): 5-10. Slot/Port information need not contain a space before and after the dash. For example. both of the following commands are valid: ; ; interface group gigabitethernet 1/1/1 - 5 ; interface group gigabitethernet 1/10/1-5.
Parameters number Enter a number as the interface number. The range is from 0 to 16383. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version 9.0.2.0 Introduced on the S6000. Version 8.3.19.0 Introduced on the S4820T. Version 8.3.11.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.11.1 Introduced on the S55, S60, and S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Introduced You cannot delete a Management port. The Management port is enabled by default (no shutdown).
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Introduced Usage Information You cannot delete the Null interface. The only configuration command possible in a Null interface is ip unreachables. Example Dell(conf)#interface null 0 Dell(conf-if-nu-0)# Related Commands interface — configures a physical interface.
Defaults None Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Usage Information Only VLAN and port-channel interfaces created using the interface vlan and interface portchannel commands can be used in the interface range command. Use the show running-config command to display the VLAN and port-channel interfaces. VLAN or port-channel interfaces that are not displayed in the show running-config command cannot be used with the bulk configuration feature of the interface range command.
interface, interface,... Enter the keywords interface range and one of the interfaces — slot/port[/ subport], port-channel, or VLAN number. Select the range of interfaces for bulk configuration. You can enter up to six comma-separated ranges. Spaces are not required between the commas. Comma-separated ranges can include VLANs, portchannels, and physical interfaces. • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
Dell(config)#interface range macro test Dell(config-if-range-te-1/1/1-3,te-5/1/1-47,te-13/1/1-89)# Related Commands interface range – configures a range of command (bulk configuration) interface range macro name – runs an interface range macro. interface range macro name Run the interface-range macro to automatically configure the pre-defined range of interfaces. Syntax interface range macro name Parameters name Enter the name of an existing macro.
interface vlan Configure a VLAN. You can configure up to 4094 VLANs. Syntax Parameters interface vlan vlan-id [of-instance{of-id}] of-instance{of-id} Enter the keyword of-instance then the OpenFlow instance ID to add the VLAN to the specified OpenFlow instance. The range is from 1 to 8. NOTE: Associate the OpenFlow instance with the VLAN when the VLAN is created. An existing VLAN cannot be associated with an OpenFlow instance.
interface null — configures a null interface. interface port-channel — configures a port channel group. show vlan — displays the current VLAN configuration on the switch. shutdown — disables/enables the VLAN. tagged — adds a Layer 2 interface to a VLAN as a tagged interface. untagged — adds a Layer 2 interface to a VLAN as an untagged interface. intf-type cr4 autoneg Set the interface type as CR4 with auto-negotiation enabled.
To stop sending keepalive packets, use the no keepalive command. Defaults Enabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Example (Single Interface) systest-3 Monitor time: 00:00:06 Refresh Intvl.
2661385 Te 1/2/1 Up 3759 3 161959604 832816 Te 1/2/2 Up 4070 3 8680346 5 Te 1/2/3 Up 61934 34 138734357 72 Te 1/2/4 Up 61427 1 59960 1 Te 1/3/1 Up 62039 53 104239232 3 Te 1/3/2 Up 17740044091 372 7373849244 79 Te 1/3/3 Up 18182889225 44 7184747584 138 Te 1/3/4 Up 18182682056 0 3682 1 Te 1/4/1 Up 18182681434 43 6592378911 144 Te 1/4/2 Up 61349 55 86281941 15 Te 1/4/3 Up 59808 58 62060 27 Te 1/4/4 Up 59889 1 61616 1 Te 1/5/1 Up 0 0 14950126 81293 Te 1/5/2 Up 0 0 0 0 Te 1/5/3 Down 0 0 0 0 Te 1/5/4 Up 62734 54
Usage Information Version Description pre-Version 6.2.1.0 Introduced on the E-Series. If the packet includes a Layer 2 header, the difference between the link MTU and IP MTU (ip mtu command) must be enough bytes to include the Layer 2 header. When you enter the no mtu command, Dell Networking OS reduces the IP MTU value to 1536 bytes. Link MTU and IP MTU considerations for port channels and VLANs are as follows. port channels: • All members must have the same link MTU value and the same IP MTU value.
Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.0 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
mode Specify autoneg mode no Negate a command or set its defaults show Show autoneg configuration information Dell(conf-if-autoneg)#mode ? forced-master Force port to master mode forced-slave Force port to slave mode Dell(conf-if-autoneg)# Example (Configured) Dell#show interfaces configured TenGigabitEthernet 13/3/4 is up, line protocol is up Hardware is Force10Eth, address is 00:01:e8:05:f7:fc Current address is 00:01:e8:05:f7:fc Interface index is 474791997 Internet address is 1.1.1.
portmode hybrid To accept both tagged and untagged frames, set a physical port or port-channel. A port configured this way is identified as a hybrid port in report displays. Syntax portmode hybrid To return a port to accept either tagged or untagged frames (non-hybrid), use the no portmode hybrid command. Defaults non-hybrid Command Modes INTERFACE (conf-if-interface-slot/port[/subport]) Command History This guide is platform-specific.
Example Dell(conf)#interface tengigabitethernet 7/1/1 Dell(conf-if-gi-7/0)#portmode hybrid Dell(conf-if-gi-7/0)#interface vlan 10 Dell(conf-if-vl-10)#untagged tengigabitethernet 7/1/1 Dell(conf-if-vl-10)#interface vlan 20 Dell(conf-if-vl-20)#tagged tengigabitethernet 7/1/1 Dell(conf-if-vl-20)# Example Dell(conf-if-vl-20)#do show interfaces switchport Name: TenGigabitEthernet 7/1/1 802.
Version Description Version 9.0.2.0 Introduced on the S6000. Version 8.3.19.0 Introduced on the S4820T. Version 8.3.11.1 Introduced on the Z9000. Version 8.3.7.0 Introduced on the S4810. Version 8.1.1.0 Introduced on the E-Series ExaScale. Version 7.6.1.0 Introduced on the S-Series. Version 7.5.1.0 Introduced on the C-Series. Version 6.1.1.0 Introduced Usage Information The output of the show interfaces command displays the configured rate interval, along with the collected traffic data.
show config (for speed) Syntax show config Command Modes INTERFACE MODE Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.1) Introduced on the S6000. Usage Information In order for the speed information corresponding to an interface to appear in the show command output, you must first configure the speed of that interface using the speed command.
Example Dell(conf)#interface range tengigabitethernet 1/1/1 - 1/1/2 Dell(conf-if-range-gi-1/1-1/1/2)#show config ! interface TenGigabitEthernet 1/1/1 no ip address switchport no shutdown ! interface TenGigabitEthernet 1/1/2 no ip address switchport no shutdown Dell(conf-if-range-gi-1/1-1/1/2)# show interfaces Display information on a specific physical interface or virtual interface.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.2 Included SFP and SFP+ optics power detail in the E-Series and C-Series output. 8.2.1.0 Added support for 4093 VLANs on the E-Series ExaScale. Prior releases supported 2094. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Output expanded to include SFP+ media on the C-Series. 7.6.1.0 Introduced on the S Series. 7.
Line Description MTU 1554... Displays link and IP MTU information. LineSpeed Displays the interface’s line speed, duplex mode, and negotiation mode. ARP type:... Displays the ARP type and the ARP timeout value for the interface. Last clearing... Displays the time when the show interfaces counters where cleared. Queuing strategy... States the packet queuing strategy. FIFO means first in first out.
Example Dell#show interfaces TenGigabitEthernet 2/1 is down, line protocol is down Hardware is DellForce10Eth, address is 00:01:e8:8b:3d:e7 Current address is 00:01:e8:8b:3d:e7 Pluggable media present, Media type is unknown Wavelength unknown Interface index is 100992002 Internet address is not set MTU 1554 bytes, IP MTU 1500 bytes LineSpeed auto Flowcontrol rx on tx off ARP type: ARPA, ARP Timeout 04:00:00 Last clearing of "show interface" counters 3d17h53m Queueing strategy: fifo Input Statistics: 0 pack
Input 00.00 Mbits/sec, 0 packets/sec, 0.00% of line-rate Output 00.00 Mbits/sec, 0 packets/sec,0.
Input 791 packets, 62913 bytes, 775 multicast Received 0 errors, 0 discarded Output 21 packets, 3300 bytes, 20 multicast Output 0 errors, 0 invalid protocol Time since last interface status change: 00:06:03 Example (OpenFlow instance) Dell#show interfaces vlan 6 Vlan 6 is down, line protocol is down Address is 00:01:e8:8a:e1:8c, Current address is 00:01:e8:8a:e1:8c Interface index is 1107525638 of-instance: 2 Internet address is not set MTU 1554 bytes, IP MTU 1500 bytes LineSpeed auto ARP type: ARPA, ARP T
Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Changed the organization of the display output.
• For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
show interfaces stack-unit Display information on all interfaces on a specific S-Series or Z-Series stack member. Syntax show interfaces stack-unit unit-number Parameters Command Modes Command History unit-number • EXEC • EXEC Privilege Enter the stack member number. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Hardware is Force10Eth, address is 00:01:e8:4c:f2:83 Current address is 00:01:e8:4c:f2:83 !-------------output truncated ----------------! Related Commands show hardware stack-unit — displays data plane and management plane input/output statistics. show interfaces — displays information on a specific physical interface or virtual interface.
Example Version Description 7.5.1.0 Introduced on the E-Series.
Output Statistics: 0 packets, 0 bytes, 0 underruns Related Commands show interfaces — displays information on a specific physical interface or virtual interface. show system stack-unit quad-port-profile Syntax Parameters Command Modes Command History Example show system [stack-unit-number] quad-port-profile stack-unit number Enter the port number. The range is from 1–6. EXEC Privilege Version 9.7(0.0) Introduced on the S6000 and S6000–ON.
stack-unit quad-port-profile Syntax stack-unit [stack-unit number] quad-port-profile [default|<1–32>] To remove the quad-port configuration, use the [no] stack-unit[stack-unit number] quadport-profile [default|<1–32>]command syntax. Parameters stack-unit number<1–32> Enter the port number. The range is from 1 to 6.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.2.1.0 Added support for 4093 VLANs on E-Series ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Support added for hybrid port/native VLAN, introduced on the S-Series. 7.5.1.0 Introduced on the C-Series.
show interfaces transceiver — displays the physical status and operational status of an installed transceiver. The output also displays the transceiver’s serial number. show interfaces transceiver Display the physical status and operational status of an installed transceiver. The output also displays the transceiver’s serial number.
Line Description Voltage High Alarm threshold Displays the interface index number used by SNMP to identify the interface. Bias High Alarm threshold Factory-defined setting. Value can differ between SFP and SFP+. TX Power High Alarm threshold Factory-defined setting. Value can differ between SFP and SFP+. RX Power High Alarm threshold Factory-defined setting. Value can differ between SFP and SFP+. Temp Low Alarm threshold Factory-defined setting. Value can differ between SFP and SFP+.
Interfaces Line Description Tx Bias Current Present transmission (Tx) bias current of the SFP. If this crosses bias high alarm/ warning thresholds, the TX bias high alarm/warning flag is set to true. If it falls below the low alarm/warning thresholds, the TX bias low alarm/warning flag is set to true. Tx Power Present Tx power of the SFP. If this crosses Tx power alarm/warning thresholds, the Tx power high alarm/warning flag is set to true.
Example Line Description Temperature High Warning Flag This can be either true or false, depending on the Current Temperature value displayed above. Voltage High Warning Flag This can be either true or false, depending on the Current Voltage value displayed above. Tx Bias High Warning Flag This can be either true or false, depending on the Tx bias current value displayed above. Tx Power High Warning Flag This can be either true or false, depending on the Current Tx power value displayed above.
SFP 1 RX Power High Alarm threshold = 1.259mW SFP 1 Temp Low Alarm threshold = -25.000C SFP 1 Voltage Low Alarm threshold = 2.700V SFP 1 Bias Low Alarm threshold = 1.000mA SFP 1 TX Power Low Alarm threshold = 0.067mW SFP 1 RX Power Low Alarm threshold = 0.010mW =================================== SFP 1 Temp High Warning threshold = 90.000C SFP 1 Voltage High Warning threshold = 3.700V SFP 1 Bias High Warning threshold = 14.000mA SFP 1 TX Power High Warning threshold = 0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information The shutdown command marks a physical interface as unavailable for traffic. To discover if an interface is disabled, use the show ip interface brief command. Disabled interfaces are listed as down.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.11.1 Introduced on the S55, S60, and S4810 8.1.1.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.1 Introduced on the S4810. Splitting a 40G port into 4x10G port is supported on standalone and stacked units. stack-unit stackunit port number portmode quad dynamically fan-out 40G ports to 10G ports and vice-versa without reload in S6000 and S6000–ON switch. The quad port must be in a default configuration before it can be split into 4x10G ports.
port-channel Enter the keywords port-channel if the backup port is a static or dynamic port channel. slot/port[/subport] Specify the line card and port number of the backup port. Defaults Disabled (The interface is in Layer 3 mode.) Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Port Channel Commands A Link Aggregation Group (LAG) is a group of links that appear to a MAC client as if they were a single link according to IEEE 802.3ad. In Dell Networking OS, a LAG is referred to as a Port Channel. • For the S-Series and Z9000, the maximum port channel ID is 128 and the maximum members per port channel is 16.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-Version 6.2.1.0 Introduced on the E-Series. Use the interface port-channel command to access this command. You cannot add an interface to a Port Channel if the interface contains an IP address in its configuration. Only the shutdown, description, mtu, and ip mtu commands can be configured on an interface if it is added to a Port Channel.
To remove an existing LAG supergroup, use the no group group_number command. Parameters group_number Enter an integer from 1 to 32 that uniquely identifies this LAG fate-sharing group. port-channel number Enter the keywords port-channel then an existing LAG number. Enter this keyword/variable combination twice, identifying the two paired LAGs. Defaults none Command Modes PORT-CHANNEL FAILOVER-GROUP (conf-po-failover-grp) Command History This guide is platform-specific.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. Version 9.0.2.0 Introduced on the S6000. Version 8.3.19.0 Introduced on the S4820T. Version 8.3.12.0 Introduced on S4810. Version 8.3.11.1 Introduced on Z9000. Version 8.1.1.0 Introduced on E-Series ExaScale. Version 7.6.1.0 Introduced on S-Series. Version 7.5.1.0 Introduced on C-Series. pre-Version 6.2.1.0 Introduced on E-Series.
minimum-links Configure the minimum number of links in a LAG (Port Channel) that must be in “oper up” status for the LAG to be also in “oper up” status. Syntax minimum-links number Parameters number Enter the number of links in a LAG that must be in “oper up” status. The range is from 1 to 16. The default is 1. Defaults 1 Command Modes INTERFACE Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. Modified to display the LAG failover group status. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information 624 Interfaces The following describes the show interfaces port-channel command shown in the following example.
Example Field Description Time since... Displays the time since the last change in the configuration of this interface. Dell#show interfaces port-channel 20 Port-channel 20 is up, line protocol is up (Failover-group 1 is down) Hardware address is 00:01:e8:01:46:fa Port-channel is part of failover-group 1 Internet address is 1.1.120.
1 L2 up 00:00:08 Dell# Related Commands Te 3/1/1 (Up) * Te 3/2/1 (Down) Te 3/3/1 (Up) show lacp — displays the LACP matrix. show port-channel-flow Display an egress port in a given port-channel flow.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.10.0 Introduced on the S4810. Because this command calculates based on a Layer 2 hash algorithm, use this command to display flows for switched Layer 2 packets, not for routed packets (use the show ip flow command to display routed packets).
Syntax ip http source-interface interface To delete an interface, use theno ip http source-interface interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
23 IPv4 Routing The basic IPv4 commands are supported by Dell Networking operating system on the platform. arp To associate an IP address with a MAC address in the switch, use address resolution protocol (ARP). Syntax arp [vrf vrf-name] ip-address mac-address interface To remove an ARP address, use the no arp ip-address command. Parameters vrf vrf-name Enter a VRF name to configure an ARP entry for that VRF. Use the VRF option after the keyword arp to configure a static arp on that particular VRF.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. You cannot use Class D or Class E IP addresses or zero IP address (0.0.0.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810. Usage Information This timer is an exponential backoff timer. Over the specified period, the time between ARP requests increases. This behavior reduces the potential for the system to slow down while waiting for a multitude of ARP responses. Related Commands show arp retries — displays the configured number of ARP retries.
arp max-entries Enables you to configure the maximum number of ARP entries per VRF that are allowed for IPv4.. Syntax arp max-entries [vrf vrf-name] max-number Parameters vrf vrf-name Enter the name of a specific VRF for which you want to configure maximum number of ARP entries that IPv4 allows. max-number Enter the maximum number of ARP entries that a VRF RTM can hold. The range is from 0 to 65535. Defaults Not configured.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced. Usage Information Retries are 20 seconds apart. Related Commands show arp retries — displays the configured number of ARP retries. arp timeout Set the time interval for an ARP entry to remain in the ARP cache. Syntax Parameters arp timeout minutes minutes Enter the number of minutes. The range is from 0 to 35790.
clear arp-cache Clear the dynamic ARP entries from a specific interface or optionally delete (no-refresh) ARP entries from the content addressable memory (CAM). Syntax clear arp-cache [vrf vrf-name | interface | ip ip-address] [no-refresh] Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to clear the ARP cache corresponding to that VRF.
Version Description 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. clear host Remove one or all dynamically learned host table entries. Syntax Parameters clear host name name Enter the name of the host to delete. Enter * to delete all host table entries.
Parameters unit-number Enter the number of the stack unit. The range is from 0 to 11. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to clear all FIB entries corresponding to that VRF. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. Use the vrf vrf-name attribute of this command to clear routes corresponding to either a specific VRF or the default VRF.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. debug arp View information on ARP transactions. Syntax debug arp [interface] [count value] To stop debugging ARP transactions, use the no debug arp command.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.10 Introduced on the E-Series. Example Dell#debug ip dhcp 00:12:21 : %RELAY-I-PACKET: BOOTP REQUEST (Unicast) received at interface 113.3.3.17 BOOTP Request, hops = 0, XID = 0xbf05140f, secs = 0, hwaddr = 00:60:CF:20:7B:8C, giaddr = 0.0.0.0 00:12:21 : %RELAY-I-BOOTREQUEST: Forwarded BOOTREQUEST for 00:60:CF:20:7B: 8C to 14.4.4.
To disable debugging, use the no debug ip icmp command. Parameters interface count value (OPTIONAL) Enter the following keywords and slot/port[/subport] or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Usage Information To stop packets from flooding the user terminal when debugging is turned on, use the count option. debug ip packet View a log of IP packets sent and received. Syntax debug ip packet [access-group name] [count value] [interface] To disable debugging, use the no debug ip packet [access-group name] [count value] [interface] command.
Usage Information Example Version Description 8.2.1.0 Added support for 4094 VLANs on the E-Series ExaScale (the prior limit was 2094). 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Added the access-group option. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Added the count option. The following describes the debug ip packet command in the following example.
IP: s=0.0.0.0, d=30.30.30.30, len 100, unroutable ICMP type=8, code=0 Usage Information To stop packets from flooding the user terminal when debugging is turned on, use the count option. The access-group option supports only the equal to (eq) operator in TCP ACL rules. Port operators not equal to (neq), greater than (gt), less than (lt), or range are not supported in access-group option (refer to the following example).
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. ip domain-list Configure names to complete unqualified host names. Syntax ip domain-list name To remove the name, use the no ip domain-list name command. Parameters name Enter a domain name to be used to complete unqualified names (that is, incomplete domain names that cannot be resolved). Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
To view current bindings, use the show hosts command. To view a DNS-related configuration, use the show running-config resolve command. Related Commands ip domain-name — specifies a DNS server. ip domain-lookup To address resolution (that is, DNS), enable dynamic host-name. Syntax ip domain-lookup To disable DNS lookup, use the no ip domain-lookup command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
ip domain-name Configure one domain name for the switch. Syntax ip domain-name name To remove the domain name, use the no ip domain-name command. Parameters name Enter one domain name to be used to complete unqualified names (that is, incomplete domain names that cannot be resolved). Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
ip helper-address Specify the address of a DHCP server so that DHCP broadcast messages can be forwarded when the DHCP server is not on the same subnet as the client. Syntax ip helper-address ip-address To remove a DHCP server address, use the no ip helper-address command. Parameters ip-address Enter an IP address in dotted decimal format (A.B.C.D). Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific.
ip helper-address hop-count disable Disable the hop-count increment for the DHCP relay agent. Syntax ip helper-address hop-count disable To re-enable the hop-count increment, use the no ip helper-address hop-count disable command. Defaults Enabled; the hops field in the DHCP message header is incremented by default. Command Modes CONFIGURATION Command History This guide is platform-specific.
To remove an IP host, use the no ip host name [ip-address] command. Parameters name Enter a text string to associate with one IP address. ip address Enter an IP address, in dotted decimal format, to be mapped to the name. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults Not configured. Command Modes CONFIGURATION Command History Usage Information • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.
NOTE: When you configure the capability to enable the loopback IP address to be sent for easy debugging and diagnosis (IP addresses of the devices for which the ICMP source interface is configured), the source IP address of the outgoing ICMP error message is modified, although the packets are not sent out using the configured interface.
ip max-frag-count Set the maximum number of fragments allowed in one packet for packet re-assembly. Syntax ip max-frag-count count To place no limit on the number of fragments allowed, use the no ip max-frag-count command. Parameters count Enter a number for the number of fragments allowed for re-assembly. The range is from 2 to 256. Defaults No limit is set on number of fragments allowed. Command Modes CONFIGURATION Command History This guide is platform-specific.
ipv4-address2... ipv4-address6 (OPTIONAL) Enter up five more IPv4 addresses, in dotted decimal format, of name servers to be used. Separate the addresses with a space. Defaults No name servers are configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. show ip interface — displays the interface routing status and configuration. ip route Assign a static route to the switch.
• For a tunnel interface, enter the keyword tunnel then the tunnel interface number. The range is from 1 to 16383. If you configure a static IPv6 route using an egress interface and enter the ping command to reach the destination IPv6 address, the ping operation may not work. Configure the IPv6 route using a next-hop IPv6 address in order for the ping command to detect the destination address. interface ip-address Enter the keyword interface then the IP address.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Using the following example of a static route: ip route 33.33.33.0 /24 tengigabitethernet 1/1 172.31.5.43 • The software installs a next hop that is not on the directly connected subnet but which recursively resolves to a next hop on the interface’s configured subnet. In the example, if tengig 1/1 has an ip address on subnet 2.2.2.0 and if 172.31.5.
Defaults Enabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.
ip unknown-unicast Enable IPv4 catch-all route. Syntax ip unknown-unicast To remove the IPv4 catch-all route (0.0.0.0/0) from the LPM route forwarding table in hardware which gets added as a default configuration after the initialization of FIB Agent module, use the no ip unknownunicast command. Defaults None Parameters Command Modes Command History Usage Information vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to enable catch-all routes corresponding to that VRF.
route prefixes are cleared from RTM Dell(conf)#no ip unicast-host-route show ip tcp initial-time Displays the interval that you configured for the device to wait before the TCP connection is attempted to be established. Syntax show ip tcp initial-time Command Modes EXEC EXEC Privilege Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL platforms.
Version Description 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. load-balance By default, for C-Series and S-Series, Dell Networking OS uses an IP 4-tuple (IP SA, IP DA, Source Port, and Destination Port) to distribute IP traffic over members of a Port Channel as well as equal-cost paths. To designate another method to balance traffic over Port Channel members, use the load-balance command.
Defaults IP 4-tuple (IP SA, IP DA, Source Port, Destination Port) Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
port | L4-destport ] mac [source-mac | source-port-id | source-module-id | dest-mac | destport-id | destmodule-id | vlan | ethertype | sourcedest-mac ] tunnel [ipv4-overipv4 | ipv4-overgre-ipv4 | mac-inmac]} • dest-port-id — Use dest-port-id field in hash calculation. • dest-module-id — Use dest-module-id field in hash calculation. • protocol — Use IPv4 protocol field in hash calculation. • vlan — Use vlan field in hash calculation.
management route Configure a static route that points to the Management interface or a forwarding router. Syntax management route {{ip-address mask | {ipv6-address prefix-length}} {forwarding-router-address | managementethernet | fortyGigE | vlan | tengigabitethernet} To remove a static route, use the no management route{{ip-address mask | {ipv6-address prefix-length}}{forwarding-router-address | managementethernet | fortyGigE | vlan | gigabitethernet | tengigabitethernet} command.
Version Description pre-6.1.1.0 Introduced on the E-Series. Usage Information When a static route (or a protocol route) overlaps with Management static route, the static route (or a protocol route) is preferred over the Management Static route. Also, Management static routes and the Management Connected prefix are not reflected in the hardware routing tables. Separate routing tables are maintained for IPv4 and IPv6 management routes. This command manages both tables.
macaddress macaddress mask (OPTIONAL) Enter the keyword macaddress then a MAC address in nn:nn:nn:nn:nn:nn format. Enter the optional MAC address mask in nn:nn:nn:nn:nn format also. static (OPTIONAL) Enter the keyword static to view entries entered manually. retries (OPTIONAL) Enter the keyword retries to show the number of ARP retries before a 20–second back off. dynamic (OPTIONAL) Enter the keyword dynamic to view dynamic entries.
Description Example Age(min) Displays the age (in minutes) of the ARP entry. Hardware Address Displays the MAC address associated with the ARP entry. Interface Displays the first two letters of the interfaces type and the slot/port associated with the ARP entry. VLAN Displays the VLAN ID, if any, associated with the ARP entry. CPU Lists which CPU the entries are stored on.
switchport mode private-vlan — sets PVLAN mode of the selected port. show arp retries Display the configured number of ARP retries. Syntax Command Modes Command History show arp retries • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Added support for IPv6 addresses. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. The following describes the show hosts command in the following example. Field Description Default domain...
Z10-3 Dell# Related Commands (perm, OK) - IP 192.71.23.1 traceroute — views the DNS resolution. ip host — configures a host. show ip cam stack-unit Display CAM entries for a port-pipe of a stack-unit on a S-Series or Z-Series switch. Syntax Parameters show ip cam stack-unit {id} [port-set {pipe-number} {ip-address mask [longer-prefixe [ecmp-group detail]]}| ecmp-group {detail | member-info [detail [group-index indexnumber]]}| summary] id Enter the stack-unit ID. The unit ID range is from 1 to 8.
Usage Information Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Added support for up to seven stack members. 7.6.1.0 Introduced on the S-Series. The following describes the show ip cam command shown in the following example. Field Description Destination Displays the destination route of the index. EC Displays 1 if the route is an ECMP route. Else, displays 0. C This is the CPU bit.
show ip fib stack-unit View all Forwarding Information Base (FIB) entries of a specific stack-unit. Syntax Parameters Command Modes Command History show ip fib stack-unit id vrf vrf-name [ip-address [mask] [longer-prefixes] | summar id Enter the S-Series stack unit ID. The unit ID range is from 1 to 8.
If weighted ECMP is enabled, then the show ip fib stack-unit command display a new column named W-EC (W displays either a value of 1 or 0 depending on whether or not a route is assigned with a weight. Example Dell#show ip fib stack-unit 1 Destination Gateway First-Hop Mac-Addr Port VId -----------------------------------------------------------------------------------1.1.1.2/32 via 1.1.1.2, Vl 1000 1.1.1.2 00:01:00:00:00:02 Te 3/12/1 1000 2.1.1.2/32 via 2.1.1.2, Vl 20 2.1.1.2 00:03:00:00:00:02 Po 10 20 0.
destination-ip address Enter the keywords destination-ip then the IP destination address in IP address format. protocol number [tcp | udp] Enter the keyword protocol then one of the protocol type keywords: tcp, udp, or protocol number The protocol number range is from 0 to 255. . src-port number Enter the keywords src-port then the source port number. destination-port number Enter the keywords destination-port then the destination port number.
show ip interface View IP-related information on all interfaces. Syntax show ip interface [interface | brief] [configured] Parameters interface (OPTIONAL) Enter the following keywords and slot/port[/subport] or number information: Command Modes Command History • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Usage Information Example Version Description 8.1.1.2 Supported on the E-Series ExaScale E600i. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. The following describes the show ip interface command shown in the following example. Lines Description TenGigabitEthernet 1/1... Displays the interface’s type, slot/port/subport, and physical and line protocol status. Internet address...
Example (Brief) Dell#show ip interface brief Interface IP-Address Protocol TenGigabitEthernet 1/1/1 unassigned down TenGigabitEthernet 1/1/2 unassigned down TenGigabitEthernet 1/1/3 unassigned TenGigabitEthernet 1/1/4 unassigned TenGigabitEthernet 1/2/1 unassigned TenGigabitEthernet 1/2/2 10.10.10.
Example Version Description pre-6.1.1.0 Introduced on the E-Series. Dell#show ip management-route Destination ----------10.1.2.0/24 172.16.1.0/24 Dell# Gateway ------ManagementEthernet 1/1 10.1.2.4 State ----Connected Active show ipv6 management-route Display the IPv6 static routes configured for the management interface.
2001:68::0/64 Dell# 2001:34::16 Active show ip protocols View information on all routing protocols enabled and active on the switch. Syntax show ip protocols Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example 680 Version Description 9.7(0.
show ip route View information, including how they were learned, about the IP routes on the switch. Syntax Parameters show ip route [vrf vrf-name] hostname | ip-address [mask] [longer-prefixes] | list prefix-list | protocol [process-id | routing-tag] | all | connected | static | summary] vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the VRF name to list the routes in the route table of a specific VRF.
The following is a list of the Dell Networking OS version history for this command. Usage Information 682 IPv4 Routing Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.9.1.0 Introduced VRF on the E-Series. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.
Field Description Last Change Identifies when the route was last changed or configured. The weight for weighted ECMP route calculations is displayed for each path in the route in show ip route command. The ECMP weight is displayed only if weighted ECMP is enabled using the ip ecmp weighted command is enabled. If weighted ECMP is disabled, the show ip route command does not show the weighted ECMP route information.
----------------- ----------S 1.1.1.0/24 100 C 4.4.4.0/24 1/4/1 00:01:32 C 6.6.6.0/24 1/16/1 00:01:25 4.4.4.2, via Te 1/4/1 , weight 1/0 00:00:01 6.6.6.2, via Te 1/16/1, Direct, Te Direct, Te weight 200 0/0 0/0 Dell# show ip route 1.1.1.0/24 Routing entry for 1.1.1.0/24 Known via "static", distance 1, metric 0 Last update 00:05:01 ago Routing Descriptor Blocks: * 4.4.4.2, via TenGigabitEthernet 1/4/1 weight 100 * 6.6.6.
show ip route list Display IP routes in an IP prefix list. Syntax Parameters Command Modes Command History show ip route vrf vrf-name list prefix-list prefix-list Enter the name of a configured prefix list. vrf vrf-name Enter the keyword vrf followed by the name of the VRF to display IP routes in an IP prefix list corresponding to that VRF. • EXEC • EXEC Privilege This guide is platform-specific.
Related Commands ip prefix-list — enters CONFIGURATION-IP PREFIX-LIST mode and configures a prefix list. show ip prefix-list summary — displays a summary of the configured prefix lists. show ip route summary View a table summarizing the IP routes in the switch. Syntax show ip route vrf vrf-name summary Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
Column Heading Description Total 1388 active... Example Displays the number of active and non-active routes and the memory usage of those routes. If there are no routes configured in the Dell Networking OS, this line does not appear.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 F10 Monitoring MIB available for the ip traffic statistics command. pre-6.1.1.0 Introduced on the E-Series. The following describes the show ip traffic summary shown in the following example.
Example • IP Statistics: Bcast: Sent: Object = f10BcastPktSent, OIDs = 1.3.6.1.4.1.6027.3.3.5.1.2 • IP Statistics: Mcast: Received: Object = f10McastPktRecv, OIDs = 1.3.6.1.4.1.6027.3.3.5.1.3 • IP Statistics: Mcast: Sent: Object = f10McastPktSent, OIDs = 1.3.6.1.4.1.6027.3.3.5.1.4 • ARP Statistics: Rcvd: Request: Object = f10ArpReqRecv, OIDs = 1.3.6.1.4.1.6027.3.3.5.2.1 • ARP Statistics: Rcvd: Replies: Object = f10ArpReplyRecv, OIDs = 1.3.6.1.4.1.6027.3.3.5.2.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 6.4.1.
Example Field Description 11603 data packets... Displays the number of data packets sent. 24 data packets retransmitted Displays the number of data packets resent. 355 ack.. Displays the number of acknowledgement packets sent and the number of packet delayed. 0 window probe... Displays the number of window probe and update packets sent. 7 Connections initiated... Displays the number of TCP connections initiated, accepted, and established. 14 Connections closed...
24 IPv6 Basics IPv6 basic commands are supported on the Dell Networking OS. NOTE: For information about the Dell Networking operating software version and platform that supports IPv6 in each software feature, refer to the IPv6 Addressing chapter of the Dell Networking OS Configuration Guide. cam-ipv6 extended-prefix Enable LPM partitioning to support IPv6 /65 to /128 route prefixes to be stored in Partition 1.
Parameters vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to clear the IPv6 routes corresponding to that VRF. * Enter the * to clear (refresh) all routes from the IPv6 routing table. ipv6-address prefixlength Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x format. The range is from /0 to /128. NOTE: The :: notation specifies successive hexadecimal fields of zeros.
warning-only When the warning-only option is used, a syslog message will be thrown when maximum number of dynamic IPv6 routes reaches the limit. Additional dynamic IPv6 routes will still be allowed. Defaults No limit is set on the maximum number of dynamic IPv6 routes for a VRF. Command Modes CONFIGURATION-VRF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OSCommand Line Reference Guide.
ipv6 unicast-host-route Enable programming of IPv6 /128 route prefixes in L3 host table. Syntax [no] ipv6 unicast-host-route Defaults Enabled by default. By default, all the IPv6/128 route prefixes are installed only in L3 host table. Command Modes CONFIGURATION Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.1) Introduced on the S6000. Usage Information You can use this command to enable programming of /128 route prefixes in L3 host table or in LPM table.
Command Modes Command History INTERFACE CONFIG Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.0) Introduced on the Z9000, S6000, S4810, S4820T, and MXL.. Usage Information Use this command to add, edit, or delete an IPv6 RDNSS address and lifetime value. You can configure up to four IPv6 RDNSS addresses. You must specify a lifetime using the lifetime or infinite parameter. Example Dell(conf-if-te-1/1/1)#ipv6 nd dns-server 1000::1 1 ipv6 route Establish a static IPv6 route.
Configure the IPv6 route using a next-hop IPv6 address in order for the ping command to detect the destination address. ipv6-address (OPTIONAL) Enter the forwarding router IPv6 address in the x:x:x:x::x format. NOTE: The :: notation specifies successive hexadecimal fields of zeros. distance (OPTIONAL) Enter a number as the metric distance assigned to the route. The range is from 1 to 255. tag value (OPTIONAL) Enter the keyword tag then a tag value number. The range is from 1 to 4294967295.
You can specify a weight for an IPv4 or IPv6 static route. If the weight value of a path is 0, then that path is not used for forwarding when weighted ECMP is in effect. Also, if a path corresponding to a static route (destination) has a non-zero weight assigned to it and other paths do not have any weight configured, then regular ECMP is used for forwarding. You can specify the weight value only to destination address and not on the egress port.
summary Defaults Command Modes Command History (OPTIONAL) View a brief list of the configured IPv6 routes. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for VRF. Introduced on S6000–ON 9.0.0.0 Introduced on the Z9000.
Field Description • Example (S-Series) + = summary routes Destination Identifies the route’s destination IPv6 address. Gateway Identifies whether the route is directly connected and on which interface the route is configured. Dist/Metric Identifies if the route has a specified distance or metric. Last Change Identifies when the route was last changed or configured.
Total 4 active route(s) using 928 bytes Dell# IPv6 Basics 701
25 IPv6 Access Control Lists (IPv6 ACLs) IPv6 ACLs and IPv6 Route Map commands are supported on Dell Networking platform. NOTE: For IPv4 ACL commands, refer to the Access Control Lists (ACL) chapter. Important Points to Remember • Certain platforms require manual CAM usage space allotment. For more information, refer to the cam-acl command. • Egress IPv6 ACL and IPv6 ACL on the Loopback interface is not supported. • Reference to an empty ACL permits any traffic.
Example Version Description 8.3.7.0 Introduced on the S4810. 8.4.2.1 Introduced on the S-Series. 8.4.2.0 Introduced on the E-Series TeraScale. 7.8.1.0 Introduced on the C-Series. Dell#show cam-acl-egress -- Chassis Egress Cam ACL -Current Settings(in block sizes) L2Acl : 1 Ipv4Acl : 1 Ipv6Acl : 2 -- Stack unit 1 -Current Settings(in block sizes) L2Acl : 1 Ipv4Acl : 1 Ipv6Acl : 2 Dell#show cam-acl Related Commands cam-acl — configures CAM profiles to support IPv6 ACLs.
Example Version Description 7.8.1.0 Introduced on the C-Series.
L2Qos : 3 Dell#show cam-acl Related Commands cam-acl — configures CAM profiles to support IPv6 ACLs. permit icmp To allow all or specific internet control message protocol (ICMP) messages, configure a filter. Syntax permit icmp {source address mask | any | host ipv6-address} {destination address | any | host ipv6-address} [count [byte]] To remove this filter, you have two choices: • Use the no seq sequence-number command if you know the filter’s sequence number.
To remove this filter, you have two choices: Parameters • Use the no seq sequence-number command syntax if you know the filter’s sequence number • Use the no permit {ipv6-protocol-number | icmp | ipv6 | tcp | udp} command ip-protocol-number Enter an IPv6 protocol number. The range is from 0 to 255. icmp Enter the keyword icmp to filter internet Control Message Protocol version 6. ipv6 Enter the keyword ipv6 to filter any internet Protocol version 6.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. ipv6 access-list Configure an access list based on IPv6 addresses or protocols. Syntax ipv6 access-list access-list-name cpu-qos {permit | deny} ospfv3 To delete an access list, use the no ipv6 access-list access-list-name command. Parameters access-list-name Enter the access list name as a string, up to 140 characters.
Usage Information Version Description 7.4.1.0 Introduced on the E-Series TeraScale. The number of entries allowed per ACL is hardware-dependent. For detailed specification on entries allowed per ACL, refer to your line card documentation. You can create an IPv6 ACL for control-plane traffic policing for OSPFv3, in addition to the CoPP support for VRRP, BGP, and ICMP. cam-acl-egress Allocate space for IPv6 egress ACLs.
Example Dell# Dell#configure Dell(conf)#cam-acl-egress ? default Reset Egress CAM ACL entries to default setting l2acl Set L2-ACL entries Dell(conf)#cam-acl-egress l2acl ? <1-4> Number of FP blocks for l2acl Dell(conf)#cam-acl-egress l2acl 1 ? ipv4acl Set IPV4-ACL entries Dell(conf)#cam-acl-egress l2acl 1 ipv4acl 1 ? ipv6acl Set IPV6-ACL entries Dell(conf)#cam-acl-egress l2acl 1 ipv4acl 1 ipv6acl ? <0-4> Number of FP blocks for IPV6 (multiples of 2) Dell(conf)#cam-acl-egress l2acl 1 ipv4acl 1 ipv6acl 2 ca
Usage Information Version Description 8.4.2.0 Introduced on the E-Series TeraScale. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series. For the new settings to take effect, save the new CAM settings to the startup-config (write-mem or copy run start), then reload the system. The total amount of space allowed is 16 FP blocks. System flow requires three blocks and these blocks cannot be reallocated. When configuring space for IPv6 ACLs, the total number of Blocks must equal 13.
26 Intermediate System to Intermediate System (ISIS) The intermediate system to intermediate system (IS-IS) protocol for IPv4 and IPv6 is supported on the S6000–ON platform. IS-IS is an interior gateway protocol that uses a shortest-path-first algorithm. IS-IS facilitates the communication between open systems, supporting routers passing both IP and OSI traffic. A router is considered an intermediate system. Networks are partitioned into manageable routing domains, called areas.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Introduced on the E-Series. To perform protocol-support consistency checks on hello packets, use this command. The adjacency-check is enabled by default. If a BFD session goes down indicating that IPv4 or IPv6 connectivity to its neighbor is lost, it does not imply that the adjacency is lost altogether. The hello adjacency runs over Layer 2, and does not require IP connectivity.
Usage Information Version Description 6.3.1.0 Version 6.3.1.0 Introduced You cannot disable leaking from one level to another; however, you can regulate the rate flow from one level to another using an IP Prefix list. If you do not configure the IP Prefix list, all routes are leaked. You can find more information in IETF RFC 2966, Domain-wide Prefix Distribution with Two-Level IS-IS. area-password Configure a hash message authentication code (HMAC) password for an area.
clear config Clear IS-IS configurations that display under the router isis heading of the show running-config command output. Syntax clear config Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. clns host Define a name-to-network service mapping point (NSAP) that you use with commands that require NSAPs and system IDs. Syntax Parameters clns host name nsap name Enter an alphanumeric string to identify the name-to-NSAP mapping.
To disable debugging of IS-IS, use the no debug isis command. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(0.2) Introduced on the Z9000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810.
Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(0.2) Introduced on the Z9000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 6.3.1.0 Introduced. debug isis snp-packets To debug IS-IS complete sequence number PDU (CSNP) and partial sequence number PDU (PSNP) packets, enable debugging on a specific interface and provides diagnostic information.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 6.3.1.0 Introduced. debug isis spf-triggers Enable debugging on the events that triggered IS-IS shortest path first (SPF) events for debugging purposes. Syntax debug isis [vrf vrf-name] spf-triggers To turn off debugging, use the no debug isis [vrf vrf-name] spf-triggers command.
To turn off debugging, use the no debug isis update-packets [interface] command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to enable the debugging information on IS-IS. This information contains updates from neighbors tied to the VRF that you specify. This command displays the debugging details of the received LSPs from the neighbors.
route-map mapname Defaults Command Modes Command History (OPTIONAL) A default route the routing process generates if the route map is satisfied. Not configured. • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Parameters description Defaults none Command Modes ROUTER ISIS Command History Related Commands Enter a description to identify the IS-IS protocol (80 characters maximum). Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. pre-7.7.1.0 Introduced. router isis — Enter ROUTER mode on the switch.
Usage Information Version Description 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 6.3.1.0 Introduced. The administrative distance indicates the trust value of incoming packets. A low administrative distance indicates a high trust rate. A high value indicates a lower trust rate. For example, a weight of 255 is interpreted that the routing information source is not trustworthy and should be ignored. distribute-list in Filter network prefixes received in updates.
Related Commands Version Description 8.3.12.0 Introduced on the S4810. 7.5.1.0 Added IPv6 ISIS support. 6.3.1.0 Introduced. • distribute-list out — suppresses networks from being advertised in updates. • redistribute — redistributes routes from one routing domain to another routing domain. distribute-list out Suppress network prefixes from being advertised in outbound updates.
Usage Information Related Commands Version Description 6.3.1.0 Introduced. You can assign a name to a routing process so a prefix list IS applied to only the routes derived from the specified routing process. • distribute-list in — filters the networks received in updates. • redistribute — redistributes routes from one routing domain to another routing domain.
To disable the password, use the no domain-password command. Parameters hmac-md5 (OPTIONAL) Enter the keywords hmac-md5 to encrypt the password using MD5. encryption-type (OPTIONAL) Enter 7 to encrypt the password using DES. password Enter an alphanumeric string up to 16 characters long. If you do not specify an encryption type or hmac-md5 keywords, the password is processed as plain text which provides limited security. Defaults No default password.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 6.3.1.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Introduced on the E-Series. graceful-restart restart-wait Enable the graceful restart maximum wait time before a restarting peer comes up. Syntax NOTE: Set the t3 timer to adjacency on the restarting router when implementing this command. graceful-restart restart-wait seconds To return to the default, use the no graceful-restart restart-wait command.
To return to the default, use the no graceful-restart t1 command. Parameters interval Enter the keyword interval to set the wait time. The range is from 5 to 120 seconds. The default is 5 seconds. retry-times Enter the keywords retry-times to set the number of times the request interval is extended until a CSNP is received from the helping router. The range is from 1 to 10 attempts. The default is 1. Defaults Refer to Parameters.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.3.1.0 Introduced on the E-Series. graceful-restart t3 Configure the overall wait time before graceful restart completes. Syntax graceful-restart t3 {adjacency | manual} seconds To return to the default, use the no graceful-restart t3 command.
Set the t3 timer to adjacency on the restarting router when implementing this command. The restarting router gets the remaining time value from its peer and adjusts its T3 value so only when you have configured graceful-restart t3 adjacency. Related Commands graceful-restart restart-wait — enables the graceful restart maximum wait time before a restarting peer comes up.
hostname dynamic Enables dynamic learning of hostnames from routers in the domain and allows the routers to advertise the hostname in LSPs. Syntax hostname dynamic To disable this command, use the no hostname dynamic command. Defaults Enabled. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. IS-IS normally purges LSPs with an incorrect data link checksum causing the LSP source to regenerate the message. A cycle of purging and regenerating LSPs can occur when a network link continues to deliver accurate LSPs even though there is a link causing data corruption. This process could cause disruption to your system operation.
• router isis — enables the IS-IS routing protocol. ipv6 router isis Enable the IPv6 IS-IS routing protocol and specify an IPv6 IS-IS process. Syntax ipv6 router isis [tag] To disable IS-IS routing, use the no router isis [tag] command. Parameters tag (OPTIONAL) This parameter is a unique name for a routing process. A null tag is assumed if the tag option is not specified. The tag name must be unique for all IP router processes for a given router. Defaults Not configured.
isis circuit-type Configure the adjacency type on interfaces. Syntax isis circuit-type {level-1 | level-1-2 | level-2-only} To return to the default values, use the no isis circuit-type command. Parameters level-1 You can form a Level 1 adjacency if there is at least one common area address between this system and neighbors. You cannot form Level 2 adjacencies on this interface.
Parameters seconds Interval of transmission time between CSNPs on multi-access networks for the designated intermediate system. The range is from 0 to 65535. The default is 10. level-1 (OPTIONAL) Independently configures the interval of time between transmission of CSNPs for Level 1. level-2 (OPTIONAL) Independently configures the interval of time between transmission of CSNPs for Level 2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. Usage Information The holdtime (the product of the hello-multiplier multiplied by the hello-interval) determines how long a neighbor waits for a hello packet before declaring the neighbor is down so routes can be recalculated. Related Commands isis hello-interval — specifies the length of time between hello packets.
To return to the default values, use the no ipv6 isis metric [default-metric] [level-1 | level-2] command. Parameters default-metric Metric assigned to the link and used to calculate the cost from each other router via the links in the network to other destinations. You can configure this metric for Level 1 or Level 2 routing. The range is from 0 to 16777215. The default is 10.
If metric value is configured to more than 63, system throughs the following warning:Warning: for metrics greater than 63, 'metric-style wide' should be configured on level-1-2, or it will be capped at 63. If the metric style is WIDE, the metric values that are greater than 63 are only effective. level-1 (OPTIONAL) Enter the keywords level-1 to configure the shortest path first (SPF) calculation for Level 1 (intra-area) routing. This setting is the default.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. isis password Configure an authentication password for an interface. Syntax isis password [hmac-md5] password [level-1 | level-2] To delete a password, use the no isis password [password] [level-1 | level-2] command. Parameters encryption-type (OPTIONAL) Enter 7 to encrypt the password using DES.
You can assign different passwords for different routing levels by using the keywords level-1 and level-2. The no form of this command disables the password for Level 1 or Level 2 routing, using the respective keywords level-1 or level-2. This password provides limited security as it is processed as plain text. isis priority Set the priority of the designated router you select.
is-type Configure IS-IS operating level for a router. Syntax is-type {level-1 | level-1-2 | level-2-only} To return to the default values, use the no is-type command. Parameters level-1 Allows a router to act as a Level 1 router. level-1-2 Allows a router to act as both a Level 1 and Level 2 router. This setting is the default. level-2-only Allows a router to act as a Level 2 router. Defaults level-1-2 Command Modes ROUTER ISIS Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Added support for LSP Throttling Enhancement. LSP throttling slows down the frequency at which LSPs are generated during network instability.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.5.1.0 Added support for LSP Throttling Enhancement. The link MTU and the LSP MTU size must be the same. Because each device can generate a maximum of 255 LSPs, consider carefully whether you use the lspmtu command. lsp-refresh-interval Set the link state PDU (LSP) refresh interval. LSPs must be refreshed before they expire.
The refresh interval must be less than the LSP lifetime specified with the max-lsp-lifetime command. A low value reduces the amount of time that undetected link state database corruption can persist at the cost of increased link utilization. A higher value reduces the link utilization the flooding of refreshed packets causes. Related Commands max-lsp-lifetime — sets the maximum interval that LSPs persist without being refreshed. max-area-addresses Configure manual area addresses.
Parameters seconds The maximum lifetime of LSP in seconds. This value must be greater than the lsp-refresh-interval command. The higher the value the longer the LSPs are kept. The range is from 1 to 65535. The default is 1200. Defaults 1200 seconds Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.8.1.0 Added support for multi-topology ISIS. 6.3.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. If you enter the metric-style wide command, the Dell Networking OS generates and accepts only new-style TLVs. The router uses less memory and other resources rather than generating both old-style and new-style TLVs. The new-style TLVs have wider metric fields than old-style TLVs.
net To configure an IS-IS network entity title (NET) for a routing process, use this mandatory command. If you did not configure a NET, the IS-IS process does not start. Syntax net network-entity-title To remove a net, use the no net network-entity-title command. Parameters network-entity-title Specify the area address and system ID for an IS-IS routing process. The first 1 to 13 bytes identify the area address. The next 6 bytes identify the system ID.
• For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults Not configured. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Defaults Command Modes Command History level-2 (OPTIONAL) Routes are independently redistributed into IS-IS as Level 2 routes. This setting is the default. route-map mapname (OPTIONAL) If you do not enter the route-map argument, all routes are redistributed. If a map-name value is not specified, no routers are imported. • metric metric-value = 0 • metric-type= internal; level-2 • ROUTER ISIS (for IPv4) • CONFIGURATION-ROUTER-ISIS-ADDRESS-FAMILY-IPV6 (for IPv6) This guide is platform-specific.
redistribute bgp Redistribute routing information from a BGP process. Syntax redistribute bgp AS number [level-1| level-1-2 | level-2] [metric metricvalue] [metric-type {external| internal}] [route-map map-name] To return to the default values, use the no redistribute bgp command with the appropriate parameters. Parameters AS number Enter a number that corresponds to the autonomous system number. The range is from 1 to 65355.
Version Description 7.5.1.0 Added support for IPv6 ISIS. 6.3.1.0 Introduced. Usage Information BGP to IS-IS redistribution supports “match” options using route maps. You can set the metric value, level, and metric-type of redistributed routes by the redistribution command. You can “set” more advanced options using route maps.
route-map mapname map-name is an identifier for a configured route map. The route map should filter imported routes from the source routing protocol to the current routing protocol. If you do not specify a map-name, all routes are redistributed. If you specify a keyword, but fail to list route map tags, no routes are imported. Defaults Refer to Parameters.
tag (OPTIONAL) This is a unique name for a routing process. A null tag is assumed if the tag option is not specified. The tag name must be unique for all IP router processes for a given router. Defaults Not configured. Command Modes ROUTER ISIS Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 7.8.1.
router isis clns host ISIS 49.0000.0001.F100.E120.0013.00 log-adjacency-changes net 49.0000.0001.F100.E120.0013.00 ! address-family ipv6 unicast maximum-paths 16 multi-topology transition set-overload-bit spf-interval level-1 100 15 20 spf-interval level-2 120 20 25 exit-address-family Example (AddressFamily_IPv6) The bold section identifies that Multi-Topology IS-IS is enabled in Transition mode.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added supported for VRF. Introduced on the S6000-ON. 9.2(0.2) Introduced on the Z9000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.1 Introduced on the S4810.
Example Field Description OL This value represents the overload bit, determining congestion. If the overload bit is set, other routers do not use this system as a transit router when calculating routes. The bold sections identify that MultiTopology IS-IS is enabled. Dell#show isis database IS-IS Level-1 Link State Database LSPID LSP Seq Num LSP Checksum LSP Holdtime ATT/P/OL ISIS.
show isis graceful-restart detail Display detailed IS-IS graceful restart related settings. Syntax show isis [vrf vrf-name] graceful-restart detail Command Modes Parameters • EXEC • EXEC Privilege vrf vrf-name (Optional) Enter the keyword vrf followed by the name if the VRf to display IS-IS graceful restart details corresponding to that VRF. NOTE: If you do not specify this option, the IS-IS graceful restart details corresponding to the default VRF are displayed.
show isis hostname Display IS-IS host names configured or learned on the switch. Syntax Parameters Command Modes Command History show isis [vrf vrf-name] hostname vrf vrf-name • EXEC • EXEC Privilege Enter the keyword vrf followed by the name of the VRF to display IS-IS host names corresponding to that VRF. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command Modes Command History • EXEC • EXEC Privilege • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a port channel interface, enter the keywords port-channel then a number. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. This guide is platform-specific.
show isis neighbors Display information about neighboring (adjacent) routers. Syntax Parameters Command Modes Command History show isis [vrf vrf-name] neighbors [level-1 | level-2] [detail] [interface] vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to display adjacent router information corresponding to that VRF. level-1 (OPTIONAL) Displays information about Level 1 IS-IS neighbors. level-2 (OPTIONAL) Displays information about Level 2 IS-IS neighbors.
Example Field Description Interface The interface, slot, and port in which the router was discovered. State The value providing status about the adjacency state. The range is Up and Init. Type This value displays the adjacency type (Layer 2, Layer 2 or both). Priority IS-IS priority the neighbor advertises. The neighbor with highest priority becomes the designated router for the interface. Uptime Displays the interfaces uptime.
Example Version Description 9.2(0.2) Introduced on the Z9000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. The bold section identifies that Multi-Topology IS-IS is enabled. Dell#show isis protocol IS-IS Router: System Id: F100.E120.0013 IS-Type: level-1-2 Manual area address(es): 49.0000.0001 Routing for area address(es): 49.0000.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Example 768 Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.2(0.2) Introduced on the Z9000. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
IS-IS: IS-IS: IS-IS: IS-IS: IS-IS: IS-IS: IS-IS: IS-IS: IS-IS: IS-IS: IS-IS: IS-IS: Dell# Level-1 LSPs flooded (sent/rcvd) Level-2 LSPs flooded (sent/rcvd) Level-1 LSPs CSNPs (sent/rcvd) : Level-2 LSPs CSNPs (sent/rcvd) : Level-1 LSPs PSNPs (sent/rcvd) : Level-2 LSPs PSNPs (sent/rcvd) : Level-1 DR Elections : 4 Level-2 DR Elections : 4 Level-1 SPF Calculations : 0 Level-2 SPF Calculations : 389 LSP checksum errors received : 0 LSP authentication failures : 0 : 0/0 : 5934/5217 0/0 472/238 0/0 10/337 spf-i
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. 7.8.1.0 Added support for multi-topology ISIS. 7.5.1.0 Added support for SPF Throttling Enhancement. This command spf-interval in CONFIG-ROUTER-ISIS-AF-IPV6 mode is used for IPv6 Multi-Topology route computation only. If using Single Topology mode, use the spf-interval command in CONFIGROUTER-ISIS mode for both IPv4 and IPv6 route computations.
27 Link Aggregation Control Protocol (LACP) This chapter contains commands for Dell Networks’s implementation of the link aggregation control protocol (LACP) for creating dynamic link aggregation groups (LAGs) — known as “port-channels” in the Dell Networking operating software. The LACP commands in this chapter are supported by Dell Networking OS on the S6000–ON platform.
Related Commands show lacp — displays the LACP configuration. debug lacp Debug LACP (configuration, events, and so on). Syntax debug lacp [config | events | pdu [interface-type [in | out]]] To disable LACP debugging, use the no [config | events | pdu [interface-type [in | out]]] command. Parameters config (OPTIONAL) Enter the keyword config to debug the LACP configuration. events (OPTIONAL) Enter the keyword events to debug the LACP event information.
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. lacp long-timeout Configure a long timeout period (30 seconds) for an LACP session. Syntax lacp long-timeout To reset the timeout period to a short timeout (1 second), use the no lacp long-timeout command. Defaults 1 second Command Modes INTERFACE (conf-if-po-number) Command History This guide is platform-specific.
lacp port-priority To influence which ports will be put in Standby mode when there is a hardware limitation that prevents all compatible ports from aggregating, configure the port priority. Syntax lacp port-priority priority-value To return to the default setting, use the no lacp port-priority priority-value command. Parameters priority-value Enter the port-priority value. The higher the value number, the lower the priority. The range is from 1 to 65535. The default is 32768.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
show lacp Display the LACP matrix. Syntax show lacp port-channel-number [sys-id | counters] Parameters Defaults port-channelnumber Enter a port-channel number. The range is from 1 to 128. sys-id (OPTIONAL) Enter the keywords sys-id and the value that identifies a system. counters (OPTIONAL) Enter the keyword counters to display the LACP counters. Without a Port Channel specified, the command clears all Port Channel counters.
Dell# Example (Sys-id) Oper: State BCEGIKNP Key 1 Priority 128 Dell#show lacp 1 sys-id Actor System ID: Priority 32768, Address 0001.e800.a12b Partner System ID: Priority 32768, Address 0001.e801.
28 Layer 2 This chapter describes commands to configure Layer 2 features. This chapter contains the following sections: • MAC Addressing Commands • Virtual LAN (VLAN) Commands • Far-End Failure Detection (FEFD) The VLAN commands are supported on all the S6000–ON platform. MAC Addressing Commands The following commands are related to configuring, managing, and viewing MAC addresses. mac-address-table aging-time Specify an aging time for MAC addresses to remove from the MAC address table.
Related Commands Version Description 8.3.1.0 On the E-Series, available in INTERFACE VLAN context, reduced the minimum aging time in the INTERFACE VLAN context from 10 seconds to 1 second. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. mac learning-limit — sets the MAC address learning limits for a selected interface. show mac-address-table aging-time — displays the MAC aging time.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Added support for output range parameter for S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Usage Information Version Description 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. For details about using this command, refer to the “NIC Teaming” section of the Layer 2 chapter in the Dell Networking OS Configuration Guide. mac learning-limit Limit the maximum number of MAC addresses (static + dynamic) learned on a selected interface.
Usage Information Version Description 7.7.1.0 Introduced on the C-Series. Added the station-move option. 6.5.1.0 Added support for MAC Learning-Limit on the LAG. This command and its options are supported on physical interfaces, static LAGs, LACP LAGs, and VLANs. If you do not specify the vlan option, the MAC address counters are not VLAN-based. That is, the sum of the addresses learned on all VLANs (not having any learning limit configuration) is counted against the MAC learning limit.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the S-Series. 7.8.1.0 Introduced on the C-Series. 7.5.1.0 Introduced on the E-Series. Usage Information This command is supported on physical interfaces, static LAGs, and LACP LAGs.
mac learning-limit station-move-violation Specify the actions for a station move violation. Syntax mac learning-limit station-move-violation {log | shutdown-both | shutdownoffending | shutdown-original} To disable a configuration, use the no mac learning-limit station-move-violation command, then the configured keyword. Parameters log Enter the keyword log to generate a syslog message on a station move violation.
Defaults Command Modes Command History none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Command Modes Command History • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. interface interfacetype (OPTIONAL) Instead of entering the keyword interface then the interface type, slot/port[/subport] information, as above, you can enter the interface type, then just a slot number.
Column Heading Description State Example Usage Information • po — Port Channel then a number. The range is from 1 to 255 for TeraScale. • te — 10 Gigabit Ethernet then a slot/port. Lists if the MAC address is in use (Active) or not in use (Inactive).
show mac-address-table aging-time Display the aging times assigned to the MAC addresses on the switch. Syntax show mac-address-table aging-time [vlan vlan-id] Parameters Command Modes Command History vlan vlan-id • EXEC • EXEC Privilege (OPTIONAL) Enter the keyword vlan then the VLAN ID to display the MAC address assigned to the VLAN. The range is from 1 to 4094. This guide is platform-specific.
interface interface Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Enter the keyword interface with the following keywords and slot/port[/subport] or number information: • For a port channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
Occasionally, while sending broadcast traffic over multiple Layer 3 VLANs, the VRRP state of a VLAN interface may continually switch between Master and Backup. NOTE: For more information, refer to VLAN Stacking and VLAN-related commands, such as portmode hybrid in the Interfaces chapter. default vlan-id Specify a VLAN as the Default VLAN. Syntax default vlan-id vlan-id To remove the default VLAN status from a VLAN and VLAN 1 does not exist, use the no default vlanid vlan-id syntax.
Parameters description Defaults none Command Modes INTERFACE VLAN Command History Related Commands Enter a text string description to identify the VLAN (80 characters maximum). Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 6.3.1.1 Introduced on the E-Series.
name Assign a name to the VLAN. Syntax name vlan-name To remove the name from the VLAN, use the no name command. Parameters vlan-name Enter up to 32 characters as the name of the VLAN. Defaults Not configured. Command Modes INTERFACE VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.1.(0.0) Updated to support OpenFlow. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Augmented to display PVLAN data for the C-Series and S-Series and revised the output to include the Description field to display a user-entered VLAN description. 7.6.1.
Column Heading Description • Example Te = ten-gigabit Ethernet Dell#show vlan Codes: * - Default VLAN, G - GVRP VLANs, P - Primary, C - Community, I Isolated Q: U - Untagged, T - Tagged, O - Openflow x - Dot1x untagged, X - Dot1x tagged o - OpenFlow untagged, O - OpenFlow tagged G - GVRP tagged, M - Vlan-stack i - Internal untagged, I - Internal tagged, v - VLT untagged, V - VLT tagged NUM Status Description Q Ports * 1 Inactive 2 Active U Po1(Te 13/1/1) T Po20(Te 13/6/1), Te 13/25/1 T Te 13/7/1 3 Active
NUM 42 Dell# Status Description Q Ports Active U Te 13/47/1 Example (Brief) Dell#show vlan br VLAN Name STG MAC Aging IP Address ---- -----------------------------------1 0 1800 unassigned 2 0 1800 2.2.2.2/24 3 0 1800 3.3.3.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.
Command Modes INTERFACE VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Defaults All interfaces in Layer 2 mode are untagged. Command Modes INTERFACE VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
debug fefd Enable debugging of FEFD. Syntax debug fefd {events | packets} [interface] To disable debugging of FEFD, use the no debug fefd {events | packets} [interface] command. Parameters events Enter the keyword events to enable debugging of FEFD state changes. packets Enter the keyword packets to enable debugging of FEFD to view information on packets sent and received.
Parameters disable Enter the keyword disable to disable FEFD for the specified interface. interval Enter the keyword interval, followed by a value to specify the FEFD interval in seconds. Range is from 3 to 300. Default is 15. mode Enter the keyword mode followed by the mode type to specify the FEFD mode. • normal: Change the link state to “unknown” when a far-end failure is detected by the software on that interface.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Legacy E-Series command.
Version Description Legacy E-Series command. Related Commands • fefd — enables far-end failure detection. fefd mode Change the FEFD mode on an interface. Syntax fefd mode {normal | aggressive}] To return the FEFD mode to the default of normal, use the no fefd mode command. Parameters normal (OPTIONAL) Enter the keyword normal to change the link state to “unknown” when a far-end failure the software detects on that interface.
fefd reset Reset all interfaces or a single interface that was in “error-disabled” mode. Syntax fefd reset [interface] Parameters interface (OPTIONAL) Enter the following keywords and slot/port[/subport] or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Defaults Not configured.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Legacy E-Series command.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. Legacy E-Series command. Usage Information If you enter only the fefd-global syntax, the mode is normal and the default interval is 15 seconds. If you disable FEFD globally (no fefd-global), the system does not remove the FEFD interface configuration. Related Commands • fefd — enables far-end failure detection.
Version Description 8.3.12.0 Introduced on the S4810. Legacy E-Series command. Usage Information Example The following describes the show fefd command shown in the following example. Field Description Interface Displays the interfaces type and number. Mode Displays the mode (aggressive or normal) or NA if the interface contains fefd reset in its configuration. Interval Displays the interval between FEFD packets.
29 Link Layer Discovery Protocol (LLDP) The link layer discovery protocol (LLDP) advertises connectivity and management from the local station to the adjacent stations on an IEEE 802 LAN. This chapter contains the following sections: • LLPD Commands • LLDP-MED Commands LLDP facilitates multi-vendor interoperability by using standard management tools to discover and make available a physical topology for network management.
Command Modes CONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. clear lldp counters Clear LLDP transmitting and receiving counters for all physical interfaces or a specific physical interface.
clear lldp neighbors Clear LLDP neighbor information for all interfaces or a specific interface. Syntax Parameters clear lldp neighbors {interface} interface Defaults none Command Modes EXEC Privilege Command History Enter the following keywords and slot/port[/subport] or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
all (OPTIONAL) Enter the keyword all to display information on all interfaces. events (OPTIONAL) Enter the keyword events to display major events such as timer events. packet (OPTIONAL) Enter the keyword packet to display information regarding packets coming in or going out. brief (OPTIONAL) Enter the keyword brief to display brief packet information. detail (OPTIONAL) Enter the keyword detail to display detailed packet information.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series.
Version Description 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. mode To receive or transmit, set LLDP. Syntax mode {tx | rx} To return to the default, use the no mode {tx | rx} command. Parameters tx Enter the keyword tx to set the mode to transmit. rx Enter the keyword rx to set the mode to receive. Defaults Both transmit and receive.
multiplier Set the number of consecutive misses before LLDP declares the interface dead. Syntax multiplier integer To return to the default, use the no multiplier integer command. Parameters integer Enter the number of consecutive misses before the LLDP declares the interface dead. The range is from 2 to 10. Defaults 4 x hello Command Modes CONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp) Command History This guide is platform-specific.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. protocol lldp (Interface) Enter the LLDP protocol in INTERFACE mode.
show lldp neighbors Display LLDP neighbor information for all interfaces or a specified interface. Syntax Parameters show lldp neighbors [interface] [detail] interface detail (OPTIONAL) Enter the following keywords and slot/port[/subport] or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
show lldp statistics Display the LLDP statistical information. Syntax show lldp statistics Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.
• LLDP-MED Network Connectivity Device — any device that provides access to an IEEE 802 LAN to an LLDP-MED endpoint device, and supports IEEE 802.1AB (LLDP) and TIA-1057 (LLDP-MED). The Dell Networking system is an LLDP-MED network connectivity device.
show lldp neighbors — displays the LLDP neighbors. advertise med guest-voice-signaling To advertise a separate limited voice service for a guest user when the guest voice control packets use a separate network policy than the voice data, configure the system.
advertise med location-identification To advertise a location identifier, configure the system. Syntax advertise med location-identification {coordinate-based value | civic-based value | ecs-elin value} To return to the default, use the no advertise med location-identification {coordinate-based value | civic-based value | ecs-elin value} command. Parameters coordinate-based value Enter the keywords coordinate-based then the coordinated based location in hexadecimal value of 16 bytes.
advertise med power-via-mdi To advertise the Extended Power via MDI TLV, configure the system. Syntax advertise med power-via-mdi To return to the default, use the no advertise med power-via-mdi command. Defaults unconfigured. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
priority-tagged number Enter the keywords priority-tagged then the Layer 2 priority. The range is from 0 to 7. Defaults unconfigured. Command Modes CONFIGURATION (conf-lldp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series and E-Series. debug lldp interface — debugs LLDP. show lldp neighbors — displays the LLDP neighbors. advertise med video-signaling To advertise video control packets that use a separate network policy than video data, configure the system.
Related Commands Version Description 7.6.1.0 Introduced on the C-Series and E-Series. debug lldp interface — debugs LLDP. show lldp neighbors — displays the LLDP neighbors. advertise med voice To advertise a dedicated IP telephony handset or other appliances supporting interactive voice services, configure the system.
advertise med voice-signaling To advertise when voice control packets use a separate network policy than voice data, configure the system. Syntax advertise med voice-signaling {vlan-id layer2_priority DSCP_value} | {priority-tagged number} To return to the default, use the no advertise med voice-signaling {vlan-id layer2_priority DSCP_value} | {priority-tagged number} command. Parameters vlan-id Enter the VLAN ID. The range is from 1 to 4094.
30 Microsoft Network Load Balancing Network Load Balancing (NLB) is a clustering functionality that is implemented by Microsoft on Windows 2000 Server and Windows Server 2003 operating systems. Microsoft NLB clustering allows multiple servers running Microsoft Windows to be represented by one MAC and one IP address to provide transparent failover and load-balancing.
Related Commands clear arp-cache — clears dynamic ARP entries from the ARP table. show arp — displays the ARP table. mac-address-table static (for Multicast MAC Address) For multicast mode of network load balancing (NLB), configure a static multicast MAC address, associate the multicast MAC address with the VLAN used to switch Layer 2 multicast traffic, and add output ports that will receive multicast streams on the VLAN.
Version 9.3(0.0) Example (Multicast) Added support for multicast MAC address on the MXL platform. mac-address-table static 01:00:5E:01:00:01 {multicast vlan 2 output—range Te 1/1/2,Te 1/1/3} ip vlan-flooding Enable unicast data traffic flooding on VLAN member ports. Syntax ip vlan-flooding To disable, use the no ip vlan-flooding command. Command Modes Command History CONFIGURATION Version 9.3(0.
31 Multicast Source Discovery Protocol (MSDP) Multicast source discovery protocol (MSDP) connects multiple PIM Sparse-Mode (PIM-SM) domains together. MSDP peers connect using TCP port 639. Peers send keepalives every 60 seconds. A peer connection is reset after 75 seconds if no MSDP packets are received. MSDP connections are parallel with MBGP connections. The Dell Networking operating system supports MSDP commands on the S6000–ON platform.
clear ip msdp sa-cache Clears the entire source-active cache, the source-active entries of a particular multicast group, rejected, or local source-active entries. Syntax clear ip msdp sa-cache [group-address | rejected-sa | local] Parameters group-address Enter the group IP address in dotted decimal format (A.B.C.D.).
peer-address Enter the IP address of the MSDP peer. Defaults Without any options, this command clears the entire source-active cache. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.4.1.0 Introduced show ip msdp sa-cache rejected-sa — displays the rejected SAs in the SA cache. ip msdp default-peer Define a default peer from which to accept all source-active (SA) messages. Syntax ip msdp default-peer peer address [list name] To remove the default peer, use the no ip msdp default-peer {peer address} list name command.
ip msdp log-adjacency-changes Enable logging of MSDP adjacency changes. Syntax ip msdp log-adjacency-changes To disable logging, use the no ip msdp log-adjacency-changes command. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.1 Introduced An MSDP mesh group is a mechanism for reducing SA flooding, typically in an intra-domain setting. When some subset of a domain’s MSDP speakers are fully meshed, they can be configured into a mesh-group.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 6.2.1.1 Introduced ip msdp peer Configure an MSDP peer. Syntax ip msdp peer peer address [connect-source] [description] [sa-limit number] To remove the MSDP peer, use the no ip msdp peer peer address [connect-source interface] [description name] [sa-limit number] command.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 7.5.1.0 Added option for SA upper limit and the description option. 6.2.1.1 Introduced The connect-source option is used to supply a source IP address for the TCP connection.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced Modifications to the ACL do not have an immediate effect on the sa-cache. To apply the redistribute filter to entries already present in the SA cache, use the clear ip msdp sacache local command.
Version Description 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the E-Series. ip msdp sa-limit Configure the upper limit of source-active (SA) entries in SA-cache. Syntax ip msdp sa-limit number To return to the default, use the no ip msdp sa-limit number command. Parameters number Enter the maximum number of SA entries in SA-cache. The range is from 1 to 500000. Defaults 50000 Command Modes CONFIGURATION Command History This guide is platform-specific.
ip msdp shutdown Administratively shut down a configured MSDP peer. Syntax Parameters ip msdp shutdown {peer address} peer address Enter the peer address in a dotted decimal format (A.B.C.D.). Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 6.2.1.1 Introduced show ip msdp Display the MSDP peer status, SA cache, or peer summary. Syntax show ip msdp {peer peer address | sa-cache | summary} Parameters Defaults peer peer address Enter the keyword peer then the peer address in a dotted decimal format (A.B.C.D.). sa-cache Enter the keywords sa-cache to display the Source-Active cache.
Input (S,G) filter: none Output (S,G) filter: none Dell# Example (Sa-cache) Dell#show ip msdp sa-cache MSDP Source-Active Cache - 1 entries GroupAddr SourceAddr RPAddr 224.1.1.1 172.21.220.10 172.21.3.254 Dell# Example (Summary) Dell#show ip msdp summary Peer Addr Local Addr Description 5.5.5.32 6.6.6.32 00:07:17 Peer1 Dell# LearnedFrom Expire UpTime 172.21.3.254 102 00:02:52 State Source Established Lo 32 SA Up/Down 20 show ip msdp sa-cache rejected-sa Display the rejected SAs in the SA cache.
00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 00:00:13 844 225.1.2.7 10.1.1.3 225.1.2.8 10.1.1.4 225.1.2.9 10.1.1.3 225.1.2.10 10.1.1.4 225.1.2.11 10.1.1.3 225.1.2.11 10.1.1.3 225.1.2.12 10.1.1.4 225.1.2.13 10.1.1.3 225.1.2.14 10.1.1.4 225.1.2.15 10.1.1.3 225.1.2.16 10.1.1.4 225.1.2.17 10.1.1.3 225.1.2.18 10.1.1.4 225.1.2.19 10.1.1.3 Multicast Source Discovery Protocol (MSDP) 110.1.1.1 110.1.1.1 110.1.1.1 110.1.1.1 110.1.1.1 110.1.1.
32 Multiple Spanning Tree Protocol (MSTP) Multiple spanning tree protocol (MSTP), as implemented by the Dell Networking operating system, conforms to IEEE 802.1s. This command supports the Dell Networking S6000–ON platform. debug spanning-tree mstp Enable debugging of the multiple spanning tree protocol and view information on the protocol.
Example Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series.
forward-delay The amount of time the interface waits in the Blocking State and the Learning State before transitioning to the Forwarding State. Syntax forward-delay seconds To return to the default setting, use the no forward-delay command. Parameters seconds Enter the number of seconds the interface waits in the Blocking State and the Learning State before transiting to the Forwarding State. The range is from 4 to 30. The default is 15 seconds.
Parameters seconds Enter a number as the time interval between transmission of BPDUs. The range is from 1 to 10. The default is 2 seconds. Defaults 2 seconds Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced. By default, all VLANs are mapped to MST instance zero (0) unless you use the vlan range command to map it to a non-zero instance.
Usage Information For two MSTP switches to be within the same MSTP region, the switches must share the same region name (including matching case). Related Commands msti — maps the VLAN(s) to an MST instance. revision — assigns the revision number to the MST configuration. protocol spanning-tree mstp To enable and configure the multiple spanning tree group, enter MULTIPLE SPANNING TREE mode.
revision The revision number for the multiple spanning tree configuration. Syntax revision range To return to the default values, use the no revision command. Parameters range Enter the revision number for the MST configuration. The range is from 0 to 65535. The default is 0. Defaults 0 Command Modes MULTIPLE SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.1 Introduced on the E-Series. Usage Information Enable the multiple spanning tree protocol prior to using this command. Example Dell#show spanning-tree mst configuration MST region name: CustomerSvc Revision: 2 MSTI VID 10 101-105 Dell# show spanning-tree msti View the multiple spanning tree instance.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.4.1.0 Expanded to display the port error disable state (EDS) loopback BPDU inconsistency causes. Usage Information Enable the multiple spanning tree protocol prior to using this command. Example Dell#show spanning-tree msti 10 MSTI 10 VLANs mapped 101-105 Bridge Identifier has priority 32768, Address 0001.e802.
-----------------------------------------------------------Te 1/1/1 ErrDis 128.257 128 20000 EDS 0 P2P No No Dell#show spanning-tree msti 0 MSTI 0 VLANs mapped 1-4094 Root Identifier has priority 32768, Address 0001.e801.6aa8 Root Bridge hello time 2, max age 20, forward delay 15, max hops 20 Bridge Identifier has priority 32768, Address 0001.e801.6aa8 Configured hello time 2, max age 20, forward delay 15, max hops 20 We are the root of MSTI 0 (CIST) Current root has priority 32768, Address 0001.e801.
Defaults Enable. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Defaults • cost = depends on the interface type • priority = 128 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced By default, Dell Networking OS implements an optimized flush mechanism for MSTP. This mechanism helps in flushing the MAC addresses only when necessary (and less often) allowing for faster convergence during topology changes.
33 Multicast The multicast commands are supported by Dell Networking operating system (OS) on all S6000–ON platform. This chapter contains the following sections: • IPv4 Multicast Commands IPv4 Multicast Commands The following section contains the IPv4 multicast commands. clear ip mroute Clear learned multicast routes on the multicast forwarding table. To clear the protocol-independent multicast (PIM) tree information base, use the clear ip pim tib command.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series. E-Series legacy command Related Commands show ip pim tib — shows the PIM tree information base. ip mroute Assign a static mroute.
Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810.
Usage Information This feature allows you to limit the number of multicast entries on the system. This number is the total of all the multicast entries on all line cards in the system. On each line card, the multicast module only installs the maximum number of entries, depending on the configured CAM profile. To store multicast routes, use the IN-L3-McastFib CAM partition. It is a separate hardware limit that exists per port-pipe. This hardware space limitation can supersede any software-configured limit.
Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. static (OPTIONAL) Enter the keyword static to view static multicast routes. group-address [source-address] (OPTIONAL) Enter the multicast group-address to view only routes associated with that group. Enter the source-address to view routes with that group-address and source-address.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Example (Static) Dell#show ip mroute static Mroute: 23.23.23.0/24, interface: Lo 2 Protocol: static, distance: 0, route-map: none, last change: 00:00:23 Example (Snooping) Dell#show ip mroute snooping IPv4 Multicast Snooping Table (*, 224.0.0.0), uptime 17:46:23 Incoming vlan: Vlan 2 Outgoing interface list: TenGigabitEthernet 4/13/1 (*, 225.1.2.
Field Description • Example received a (*,G) or (S,G) Join message Dell#show ip mroute IP Multicast Routing Table (*, 224.10.10.1), uptime 00:05:12 Incoming interface: TenGigabitEthernet 3/12/1 Outgoing interface list: TenGigabitEthernet 3/13/1 (1.13.1.100, 224.10.10.1), uptime 00:04:03 Incoming interface: TenGigabitEthernet 3/4/1 Outgoing interface list: TenGigabitEthernet 3/12/1 TenGigabitEthernet 3/13/1 (*, 224.20.20.
Example Dell#show ip rpf RPF information for 10.10.10.9 RPF interface: Te 3/4/1 RPF neighbor: 165.87.31.4 RPF route/mask: 10.10.10.9/255.255.255.
34 Neighbor Discovery Protocol (NDP) The neighbor discovery protocol for IPv6 is defined in RFC 2461 as part of the Stateless Address Autoconfiguration protocol. It replaces the Address Resolution Protocol used with IPv4.
clear ipv6 neighbors Delete all entries in the IPv6 neighbor discovery cache or neighbors of a specific interface. Static entries are not removed using this command. Syntax Parameters clear ipv6 neighbors [ipv6-address | interface] ipv6-address Enter the IPv6 address of the neighbor in the x:x:x:x::x format to remove a specific IPv6 neighbor. NOTE: The :: notation specifies successive hexadecimal fields of zero.
count value • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Enter the keyword count then the number of debug outputs. The range is from 1 to 65534. The default is infinity. Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
hop-limit Enable the verification of the advertised hop count limit. If this command is not configured, the verification process is bypassed. Syntax hop-limit {maximum | minimum limit} To reset the hop count limit, use the no hop-limit {maximum | minimum limit} command. Parameters maximum limit Enter the keyword maximum then the hop limit value. The range is from 0 to 254. minimum limit Enter the keyword minimum then the hop limit value. The range is from 0 to 254.
Related Commands Version Description 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. show ipv6 nd ra-guard policy — Displays the configuration applied on all the RA guard policies or a specific RA guard policy. ipv6 nd ra-guard enable Allow you to configure the RA guard related commands. Syntax ipv6 nd ra-guard enable To disable the RA guard, use the no ipv6 nd ra-guard enable command.
ipv6 neighbor Configure a static entry in the IPv6 neighbor discovery. Syntax ipv6 neighbor {ipv6-address} {interface interface} {hardware_address} To remove a static IPv6 entry from the IPv6 neighbor discovery, use the no ipv6 neighbor {ipv6address} {interface interface} command. Parameters ipv6-address Enter the IPv6 address of the neighbor in the x:x:x:x::x format. NOTE: The :: notation specifies successive hexadecimal fields of zero.
managed-config-flag Set the managed address configuration flag. Syntax managed-config-flag {on | off} To clear the flag, use the no managed-config-flag {on | off} command. Parameters on Enter the keyword on to set the managed-config-flag value as ON. off Enter the keyword off to set the managed-config flag value as OFF. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. • ipv6 nd ra-guard enable — Allows you to configure the RA guard related commands. • ipv6 nd raguard policy policy-name — Defines the RA guard policy name and enter the RA guard policy configuration mode.
To reset the MTU value, use the no mtu value command. Parameters value Enter the maximum transmission unit value in bytes. The range is from 1,280 to 11,982 bytes. Defaults 0 Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
reachable-time Enable the verification of the configured reachability time in the received RA packets. Syntax reachable—time value To reset the advertised reachability time, use the no reachable-timevalue command. Parameters value Enter the advertised reachability time in milliseconds. The range is from 0 to 3,600,000 milliseconds. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific.
Related Commands ipv6 nd raguard policy policy-name — Defines the router advertisement (RA) guard policy name and enter the RA guard policy configuration mode. router-lifetime Set the router lifetime. Syntax router—lifetime value Parameters value Enter the router lifetime in seconds. The range is from 0 to 9,000 seconds. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific.
Related Commands Version Description 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, and Z9000 switches. • ipv6 nd ra-guard enable — Allow you to configure the RA guard related commands. • ipv6 nd raguard policy policy-name — Defines the router advertisement (RA) guard policy name and enter the RA guard policy configuration mode. show config Display the RA guard policy mode configurations.
show ipv6 nd ra-guard policy Display the configurations applied on all the RA guard policies or a specific RA guard policy. Syntax show ipv6 nd ra-guard policy policy-name Parameter policy policy-name Enter the keyword policy then the policy name. The policy name allows a maximum of 140 characters. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
show ipv6 neighbors Display IPv6 discovery information. Entering the command without options shows all IPv6 neighbor addresses stored on the control processor (CP).
trusted-port Allow bypassing the configured RA guard validation and forwards the RA packets received on the interface, which has the trusted port policy attached. Syntax trusted-port To reset the policy applied to the trusted port, use the no trusted-port command. Defaults none Command Modes POLICY LIST CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
35 Object Tracking Object Tracking supports IPv4 and IPv6, and is available on the Dell Networking, C-Series, E-Series, S-Series, and S4810 platforms. Object tracking allows you to define objects of interest, monitor their state, and report to a client when a change in an object’s state occurs.
Example Version Description 8.4.1.0 Introduced. Dell#debug track all 04:35:04: %RPM0-P:RP2 %OTM-5-STATE: track 6 - Interface TenGigabitEthernet 1/2/1 line-protocol DOWN 04:35:04: %RPM0-P:RP2 %OTM-5-NOTIF: VRRP notification: resource ID 6 DOWN delay Configure the time delay used before communicating a change in the status of a tracked object to clients. Syntax delay {[up seconds] [down seconds]} To return to the default setting, use the no delay command.
description Enter a description of a tracked object. Syntax description {text} To remove the description, use the no description {text} command. Parameters text Enter a description to identify a tracked object (80 characters maximum). Defaults none Command Modes OBJECT TRACKING (conf_track_object-id) Command History Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced.
track 4 interface TenGigabitEthernet 1/2/1 ip routing track 5 ip route 192.168.0.0/24 reachability vrf red track resolution ip route isis 20 track resolution ip route ospf 10 Example (Object-id) Dell#show running-config track 300 track 300 ip route 10.0.0.0/8 metric threshold delay down 3 delay up 5 threshold metric up 100 Related Commands • show track – displays information about tracked objects, including configuration, current state, and clients which track the object.
Example Output Description Track object-id Displays the number of the tracked object. Interface type slot/ port, IP route ipaddress, IPv6 route ipv6-address Displays the interface type and slot/port number or address of the IPv4/IPv6 route that is being tracked. object is Up/Down Up/Down state of tracked object; for example, IPv4 interface, reachability or metric threshold of an IP route.
Related Commands • show running-config track – displays configuration information about tracked objects. • track interface ip routing – configures object tracking on the routing status of an IPv4 Layer 3 interface. • track interface line-protocol – configures object tracking on the line-protocol state of a Layer 2 interface. • track ip route metric threshold – configures object tracking on the threshold of an IPv4 route metric.
The tracking process uses a protocol-specific resolution value to convert the actual metric in the routing table to a scaled metric in the range 0 to 255. You can configure the resolution value used to scale route metrics for supported protocols with the track resolution ip route and track resolution ipv6 route commands. Related Commands • track ip route metric threshold – configures object tracking on the threshold of an IPv4 route metric.
track interface line-protocol Configure object tracking on the line-protocol state of a Layer 2 interface. Syntax track object-id interface interface line-protocol To return to the default setting, use the no track object-id command. Parameters object-id Enter the ID number of the tracked object. The range is 1 to 500.
ip-address/ prefixlen Enter an IPv4 address in dotted decimal format. The valid IPv4 prefix lengths are from /0 to /32. vrf vrf-name (Optional) E-Series only: You can configure a VPN routing and forwarding (VRF) instance to specify the virtual routing table to which the tracked route belongs. Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced.
Parameters object-id Enter the ID number of the tracked object. The range is 1 to 500. ip-address/ prefixlen Enter an IPv4 address in dotted decimal format. The valid IPv4 prefix lengths are from /0 to /32. vrf vrf-name (Optional) E-Series only: You can configure a VPN routing and forwarding (VRF) instance to specify the virtual routing table to which the tracked route belongs. Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.
Defaults none Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. Use this command to configure the protocol-specific resolution value that converts the actual metric of an IPv4 route in the routing table to a scaled metric in the range 0 to 255.
show track ipv6 route Display information about all tracked IPv6 routes, including configuration, current tracked state (UP or DOWN), and the clients which are tracking an object. Syntax show track ipv6 route [brief] Parameters Command Modes Command History Usage Information Example brief • EXEC • EXEC Privilege (OPTIONAL) Display a single line summary of information for tracked IPv6 routes. Version Description 9.7(0.0) Introduced on the S6000-ON. 8.3.12.0 Introduced on the S4810. 8.4.1.
Usage Command Example (Brief) The following describes the show track ipv6 route brief command shown in the Example below. Ouput Description ResID Number of the tracked object. Resource Type of tracked object. Parameter Detailed description of the tracked object. State Up or Down state of the tracked object. Last Change Time since the last change in the state of the tracked object.
Usage Information Related Commands Version Description 8.3.12.0 Introduced on the S4810. 8.4.1.0 Introduced. Use this command to create an object that tracks the routing state of an IPv6 Layer 3 interface: • The status of the IPv6 interface is UP only if the Layer 2 status of the interface is UP and the interface has a valid IP address.
considers a lower value to have priority over a higher value. The resulting scaled value is compared against the configured threshold values to determine the state of a tracked route as follows: • If the scaled metric for a route entry is less than or equal to the UP threshold, the state of a route is UP. • If the scaled metric for a route is greater than or equal to the DOWN threshold or the route is not entered in the routing table, the state of a route is DOWN.
If the next-hop address in the ARP cache ages out for a route tracked for its reachability, an attempt is made to regenerate the ARP cache entry to if the next-hop address appears before considering the route DOWN. Related Commands • show track ipv6 route – displays information about tracked IPv6 routes, including configuration, current state, and clients which track the route. • track ipv6 route reachability – configures object tracking on the reachability of an IPv4 route.
Related Commands • threshold metric – configures the metric threshold used to determine the UP and/or DOWN state of a tracked route. • track ipv6 route metric threshold – configures object tracking on the threshold of an IPv6 route metric.
36 Open Shortest Path First (OSPFv2 and OSPFv3) Open Shortest Path First version 2 for IPv4 is supported on platform. OSPF is an Interior Gateway Protocol (IGP), which means that it distributes routing information between routers in a single Autonomous System (AS). OSPF is also a link-state protocol in which all routers contain forwarding tables derived from information about their links to their neighbors.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. area range Summarize routes matching an address/mask at an area border router (ABR).
Version Description pre- 6.1.1.1 Introduced on the E-Series. Usage Information Only the routes within an area are summarized, and that summary is advertised to other areas by the ABR. External routes are not summarized. Related Commands area stub — creates a stub area. router ospf — enters ROUTER OSPF mode to configure an OSPF instance. area stub Configure a stub area, which is an area not connected to other areas.
auto-cost Specify how the OSPF interface cost is calculated based on the reference bandwidth method. S6000–ON Syntax auto-cost [reference-bandwidth ref-bw] To return to the default bandwidth or to assign cost based on the interface type, use the no auto-cost [reference-bandwidth] command. Parameters ref-bw (OPTIONAL) Specify a reference bandwidth in megabits per second. The range is from 1 to 4294967. The default is 100 megabits per second. Defaults 100 megabits per second.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.
Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Added the database-timer rate-limit option for the S4810. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series.
Example Field Description dst: Displays the destination IP address. netmask: Displays the destination IP address mask.
• route-map mapname 2 = Type 2 external route (OPTIONAL) Enter the keywords route-map then the name of an established route map. Defaults Disabled. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for the Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. description Add a description about the selected OSPF configuration. S6000–ON Syntax description description To remove the OSPF description, use the no description command.
distance Define an administrative distance for particular routes to a specific IP address. S6000–ON Syntax distance weight [ip-address mask access-list-name] To delete the settings, use the no distance weight [ip-address mask access-list-name] command. Parameters weight Specify an administrative distance. The range is from 1 to 255. The default is 110. ip-address (OPTIONAL) Enter a router ID in the dotted decimal format. If you enter a router ID, include the mask for that router address.
Parameters Defaults external dist3 (OPTIONAL) Enter the keyword external then a number to specify a distance for external type 5 and 7 routes. The range is from 1 to 255. The default is 110. inter-area dist2 (OPTIONAL) Enter the keywords inter-area then a number to specify a distance metric for routes between areas. The range is from 1 to 255. The default is 110. intra-area dist1 (OPTIONAL) Enter the keywords intra-area then a number to specify a distance metric for all routes within an area.
• For Port Channel groups, enter the keywords port-channel then a number. For the C-Series, S-Series, and Z9000, the range is from 1 to 128.For Z9500, the range is from 1 to 512. • For a SONET interface, enter the keyword sonet then the slot/port information. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
connected (OPTIONAL) Enter the keyword connected to specify that connected routes are distributed. isis (OPTIONAL) Enter the keyword isis to specify that IS-IS routes are distributed. NOTE: BGP and ISIS routes are not available on the C-Series. BGP, ISIS, and RIP routes are not available on the S-Series. rip (OPTIONAL) Enter the keyword rip to specify that RIP routes are distributed. NOTE: BGP and ISIS routes are not available on the C-Series.
Parameters number Enter the convergence level desired. The higher this parameter is set, the faster OSPF converge takes place. The range is from 1 to 4. Defaults none. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series and E-Series. In OSPF, flooding is the most resource-consuming task. The flooding algorithm, described in RFC-2328, requires that OSPF flood LSAs (Link State Advertisements) on all interfaces, as governed by LSA’s flooding scope (see Section 13 of the RFC).
Usage Information Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. Added support for Multi-Process OSPF. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. The Helper mode is enabled by default on the device. To enable the restart mode also on the device, you must configure the grace period using this command. After you enable restart mode the router advertises the neighbor as fully adjacent during a restart.
graceful-restart mode Enable the graceful restart mode. S6000–ON Syntax graceful-restart mode [planned-only | unplanned-only] To disable graceful restart mode, use the no graceful-restart mode command. Parameters planned-only (OPTIONAL) Enter the keywords planned-only to indicate graceful restart is supported in a planned restart condition only. unplanned-only (OPTIONAL) Enter the keywords unplanned-only to indicate graceful restart is supported in an unplanned restart condition only.
Defaults By default, OSPF routers are both helper and restart routers during a graceful restart. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T.
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. ip ospf authentication-key Enable authentication and set an authentication key on OSPF traffic on an interface. S6000–ON Syntax ip ospf authentication-key [encryption-type] key To delete an authentication key, use the no ip ospf authentication-key command. Parameters encryption-type (OPTIONAL) Enter 7 to encrypt the key.
To return to default value, use the no ip ospf cost command. Parameters cost Enter a number as the cost. The range is from 1 to 65535. Defaults The default cost is based on the reference bandwidth. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. Usage Information By default, the dead interval is four times the default hello-interval.
Usage Information The time interval between the hello packets must be the same for routers in a network. Related Commands ip ospf dead-interval — sets the time interval before a router is declared dead. ip ospf message-digest-key Enable OSPF MD5 authentication and send an OSPF message digest key on the interface. S6000–ON Syntax ip ospf message-digest-key keyid md5 key To delete a key, use the no ip ospf message-digest-key keyid command. Parameters keyid Enter a number as the key ID.
NOTE: The MD5 secret is stored as plain text in the configuration file with service password encryption. Write down or otherwise record the key. You cannot learn the key once it is configured. Use caution when changing the key. ip ospf mtu-ignore Disable OSPF MTU mismatch detection upon receipt of database description (DBD) packets. S6000–ON Syntax ip ospf mtu-ignore To return to the default, use the no ip ospf mtu-ignore command. Defaults Enabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.
Usage Information Version Description pre- 6.1.1.1 Introduced on the E-Series. Setting a priority of 0 makes the router ineligible for election as a designated router or backup designated router. Use this command for interfaces connected to multi-access networks, not point-to-point networks. ip ospf retransmit-interval Set the retransmission time between lost link state advertisements (LSAs) for adjacencies belonging to the interface.
ip ospf transmit-delay To send a link state update packet on the interface, set the estimated time elapsed. S6000–ON Syntax ip ospf transmit-delay seconds To return to the default value, use the no ip ospf transmit-delay command. Parameters seconds Enter the number of seconds as the interval between retransmission. The range is from 1 to 3600. The default is 1 second. This value must be greater than the transmission and propagation delays for the interface.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support for Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. mib-binding Enable this OSPF process ID to manage the SNMP traps and process SNMP queries. S6000–ON Syntax mib-binding To mib-binding on this OSPF process, use the no mib-binding command. Defaults none. Command Modes ROUTER OSPF Command History This guide is platform-specific.
mask Enter a network mask in /prefix format. (/x) area-id Enter the OSPF area ID as either a decimal value or in a valid IP address. Decimal value range is from 0 to 65535. IP address format is dotted decimal format A.B.C.D. NOTE: If the area ID is smaller than 65535, it is converted to a decimal value. For example, if you use an area ID of 0.0.0.1, it is converted to 1. Command Modes ROUTER OSPF Command History This guide is platform-specific.
interface Enter the following keywords and slot/port or number information: • For a Gigabit Ethernet interface, enter the keyword GigabitEthernet then the slot/port information. • For Port Channel groups, enter the keywords port-channel then a number. For the C-Series, S-Series, and Z9000, the range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
• All present and future OSPF interfaces are marked as passive. • Any adjacency is explicitly terminated from all OSPF interfaces. • All previous passive-interface interface commands are removed from the running configuration. • All previous no passive-interface interface commands are removed from the running configuration. no passive-interface interface • Remove the interface from the passive list. • The ABR status for the router is updated.
route-map mapname (OPTIONAL) Enter the keywords route-map then the name of the route map. tag tag-value (OPTIONAL) Enter the keyword tag then a number. The range is from 0 to 4294967295. Defaults Not configured. Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
metric-type typevalue (OPTIONAL) Enter the keywords metric-type then one of the following: • 1 = for OSPF External type 1 • 2 = for OSPF External type 2 route-map mapname (OPTIONAL) Enter the keywords route-map then the name of the route map. tag tag-value (OPTIONAL) Enter the keyword tag to set the tag for routes redistributed into OSPF. The range is from 0 to 4294967295. Defaults none Command Modes ROUTER OSPF Command History This guide is platform-specific.
level-1-2 (OPTIONAL) Enter the keywords level-1-2 to redistribute both IS-IS Level-1 and Level-2 routes. level-2 (OPTIONAL) Enter the keywords level-2 to redistribute only IS-IS Level-2 routes. metric metric-value (OPTIONAL) Enter the keyword metric then a number. The range is from 0 (zero) to 4294967295.
Command Modes ROUTER OSPF Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Added support for OSPFv3 on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Example Dell(conf-router_ospf)#show config ! router ospf 3 passive-interface 0 TenGigabitEthernet 1/1/1 Dell(conf-router_ospf)# show ip ospf Display information on the OSPF process configured on the switch. S6000–ON Syntax show ip ospf [process-id] Parameters Command Modes Command History process-id • EXEC • EXEC Privilege Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. This guide is platform-specific.
Line Beginning with Description “Supports only...” Displays the number of Type of Service (TOS) rouse supported. “SPF schedule...” Displays the delay and hold time configured for this process ID. “Convergence Level” “Min LSA....” Displays the intervals set for LSA transmission and acceptance. “Number of...” Displays the number and type of areas configured for this process ID. Example Dell#show ip ospf 10 Routing Process ospf 10 with ID 1.1.1.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support of Multi-Process OSPF. 7.8.1.0 Added the process-id option, in support of Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series and E-Series. To isolate problems with external routes, use this command.
Usage Information Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Added support of Multi-Process OSPF. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. The following describes the show ip ospf process-id database command shown in the following example.
172.16.1.0 Dell> Related Commands 13.1.1.1 148 0x8000006d 0x533b 0 show ip ospf database asbr-summary — displays only ASBR summary LSA information. show ip ospf database asbr-summary Display information about autonomous system (AS) boundary LSAs. S6000–ON Syntax show ip ospf [process-id | vrf vrf-name] database asbr-summary [link-stateid] [adv-router ip-address] Parameters process-id Enter the OSPF Process ID to show a specific process.
Example Field Description LS Age Displays the LSA’s age. Options Displays the optional capabilities available on router. The following options can be found in this item: • TOS-capability or No TOS-capability is displayed depending on whether the router can support Type of Service. • DC or No DC is displayed depending on whether the originating router can support OSPF over demand circuits. • E or No E is displayed on whether the originating router can accept AS External LSAs.
show ip ospf database external Display information on the AS external (type 5) LSAs. Syntax show ip ospf [process-id] database external [link-state-id] [adv-router ipaddress] Parameters process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. link-state-id (OPTIONAL) Specify LSA ID in dotted decimal format.
Field Example Description • TOS-capability or No TOS-capability is displayed depending on whether the router can support Type of Service. • DC or No DC is displayed depending on whether the originating router can support OSPF over demand circuits. • E or No E is displayed on whether the originating router can accept AS External LSAs. LS Type Displays the LSA’s type. Link State ID Displays the Link State ID. Advertising Router Identifies the router ID of the LSA’s originating router.
Metrics Type: 2 TOS: 0 Metrics: 1 Forward Address: 0.0.0.0 External Route Tag: 701 Dell# Related Commands show ip ospf database — displays OSPF database information. show ip ospf database network Display the network (type 2) LSA information. Syntax show ip ospf [process-id] database network [link-state-id] [adv-router ipaddress] Parameters process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Usage Information Example The following describes the show ip ospf process-id database network command shown in the following example. Field Description LS Age Displays the LSA’s age. Options Displays the optional capabilities available on router. The following options can be found in this item: • TOS-capability or No TOS-capability is displayed depending on whether the router can support Type of Service.
Related Commands show ip ospf database — displays OSPF database information. show ip ospf database nssa-external Display NSSA-External (type 7) LSA information. Syntax show ip ospf [process-id] database nssa-external [link-state-id] [advrouter ip-address] Parameters process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. link-state-id (OPTIONAL) Specify LSA ID in dotted decimal format.
show ip ospf database opaque-area Display the opaque-area (type 10) LSA information. Syntax Parameters show ip ospf [process-id] database opaque-area [link-state-id] [adv-router ip-address] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. link-state-id (OPTIONAL) Specify LSA ID in dotted decimal format.
Item Example Description • TOS-capability or No TOS-capability is displayed depending on whether the router can support Type of Service. • DC or No DC is displayed depending on whether the originating router can support OSPF over demand circuits. • E or No E is displayed on whether the originating router can accept AS External LSAs. LS Type Displays the LSA’s type. Link State ID Displays the Link State ID. Advertising Router Identifies the advertising router’s ID.
link-state-id adv-router ipaddress Command Modes Command History • EXEC • EXEC Privilege (OPTIONAL) Specify LSA ID in dotted decimal format. The LSA ID value depends on the LSA type, and it can be one of the following: • the network’s IP address for Type 3 LSAs or Type 5 LSAs • the router’s OSPF router ID for Type 1 LSAs or Type 4 LSAs • the default destination (0.0.0.
• adv-router ipaddress Command Modes Command History • EXEC • EXEC Privilege the default destination (0.0.0.0) for Type 5 LSAs (OPTIONAL) Enter the keywords adv-router then the IP address of an Advertising Router to display only the LSA information about that router. This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.20 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Example Item Description (Link ID) Identifies the link type and address. (Link Data) Identifies the router interface address. Number of TOS Metric Lists the number of TOS metrics. TOS 0 Metric Lists the number of TOS 0 metrics. Dell#show ip ospf 100 database router OSPF Router with ID (1.1.1.10) (Process ID 100) Router (Area 0) LS age: 967 Options: (No TOS-capability, No DC, E) LS type: Router Link State ID: 1.1.1.10 Advertising Router: 1.1.1.
show ip ospf database summary Display the network summary (type 3) LSA routing information. Syntax Parameters show ip ospf [process-id] database summary [link-state-id] [adv-router ipaddress] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. link-state-id (OPTIONAL) Specify LSA ID in dotted decimal format.
Item Example Description • TOS-capability or No TOS-capability is displayed depending on whether the router can support Type of Service. • DC or No DC is displayed depending on whether the originating router can support OSPF over demand circuits. • E or No E is displayed on whether the originating router can accept AS External LSAs. LS Type Displays the LSA type. Link State ID Displays the Link State ID. Advertising Router Identifies the router ID of the LSA’s originating router.
Dell# Related Commands show ip ospf database — displays OSPF database information. show ip ospf interface Display the OSPF interfaces configured. If OSPF is not enabled on the switch, no output is generated. Syntax Parameters Command Modes Command History show ip ospf [process-id | vrf vrf-name] interface [interface] process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process.
Usage Information Example Version Description pre-6.1.1.1 Introduced on the E-Series. The following describes the show ip ospf process-id interface command shown in the following example. Item Description GigabitEthernet... This line identifies the interface type slot/port and the status of the OSPF protocol on that interface. Internet Address... This line displays the IP address, network mask and area assigned to this interface. Process ID...
Loopback interface is treated as a stub Host. Dell> show ip ospf neighbor Display the OSPF neighbors connected to the local router. Syntax Parameters show ip ospf [process-id] neighbor process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. Command Modes EXEC Privilege Command History This guide is platform-specific.
192.10.10.2 1 FULL/DR 00:00:37 192.10.10.2 Te 1/2/1 0.0.0.1 20.20.20.1 1 FULL/DROTHER00:00:36 192.10.10.4 Te 1/3/1 0.0.0.1 Dell# show ip ospf routes Display routes OSPF calculates and stores in OSPF RIB. Syntax show ip ospf [process-id] routes Parameters Defaults process-id Enter the OSPF Process ID to show a specific process. If no Process ID is entered, command applies only to the first OSPF process. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
NOTE: Starting with Version 9.4(0.0), the loopback IP address advertised to the neighbor is not displayed in the output because they are not accounted as inactive OSPF routes, whereas the loopback IP address is displayed until Dell Networking OS Version 9.3(0.0). Starting with Version 9.4(0.0), the show ip ospf routes command displays the interface and area ID information of connected networks in addition to the other settings, whereas these details are not displayed until Dell Networking OS Version 9.3(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Example Error Type Description Intf_Down Received packets on an interface that is either down or OSPF is not enabled. Non-Dr Received packets with a destination address of ALL_DRS even though SELF is not a designated router. Self-Org Receive the self originated packet. Wrong_Len The received packet length is different to what was indicated in the OSPF header. Invld-Nbr LSA, LSR, LSU, and DDB are received from a peer which is not a neighbor peer.
Example (Statistics) • The hello-timer remaining value for each interface • The wait-timer remaining value for each interface • The grace-timer remaining value for each interface • The packet count received and transmitted for each neighbor • Dead timer remaining value for each neighbor • Transmit timer remaining value for each neighbor • The LSU Q length and its highest mark for each neighbor • The LSR Q length and its highest mark for each neighbor Dell(conf-if-te-1/6/1)#do show ip ospf s
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810. Dell#show ip ospf 10 timers rate-limit List of LSAs in rate limit Queue LSA id: 1.1.1.0 Type: 3 Adv Rtid: 3.3.3.3 Expiry time: 00:00:09.111 LSA id: 3.3.3.3 Type: 1 Adv Rtid: 3.3.3.3 Expiry time: 00:00:23.96 Dell# show ip ospf topology Display routers in directly connected areas.
Usage Information To isolate problems with inter-area and external routes, use this command. In OSPF inter-area and external routes are calculated by adding LSA cost to the cost of reaching the router. If an inter-area or external route is not of correct cost, the display can determine if the path to the originating router is correct or not. Example Dell#show ip ospf 1 topology Router ID 3.3.3.3 1.1.1.1 Dell# Flags Cost E/B/-/ 1 E/-/-/ 1 Nexthop 20.0.0.3 10.0.0.
With the not-advertise parameter configured, you can use this command to filter out some external routes. For example, if you want to redistribute static routes to OSPF, but you don't want OSPF to advertise routes with prefix 1.1.0.0, you can configure the summary-address 1.1.0.0 255.255.0.0 not-advertise to filter out all the routes fall in range 1.1.0.0/16. Related Commands area range — summarizes routes within an area.
timers throttle lsa all Configure LSA transmit intervals. Syntax timers throttle lsa all {start-interval | hold-interval | max-interval} To return to the default, use the no timers throttle lsa command. Parameters Defaults start-interval Set the minimum interval between initial sending and resending the same LSA. The range is from 0 to 600,000 milliseconds. hold-interval Set the next interval to send the same LSA.
timers throttle lsa arrival Configure the LSA acceptance intervals. Syntax timers throttle lsa arrival arrival-time To return to the default, use the no timers throttle lsa command. Parameters arrival-time Set the interval between receiving the same LSA repeatedly, to allow sufficient time for the system to accept the LSA. The range is from 0 to 600,000 milliseconds. Defaults 1000 msec Command Modes ROUTER OSPF Command History This guide is platform-specific.
The range is from 0 to 4294967295. ipsec spi number Security Policy index (SPI) value that identifies an IPsec security policy. The range is from 256 to 4294967295. MD5 | SHA1 Authentication type: Message Digest 5 (MD5) or Secure Hash Algorithm 1 (SHA-1). key-encryptiontype (OPTIONAL) Specifies if the key is encrypted. The values are 0 (key is not encrypted) or 7 (key is encrypted). key Text string used in authentication.
show crypto ipsec policy – displays the configuration of IPsec authentication policies. area encryption Configure an IPsec encryption policy for OSPFv3 packets in an OSPFv3 area. Syntax Parameters area area-id encryption ipsec spi number esp encryption-algorithm [keyencryption-type] key authentication-algorithm [key-encryption-type] key area area-id Area for which OSPFv3 traffic is to be encrypted. For area-id, enter a number. The range is from 0 to 4294967295.
null Causes an encryption policy configured for the area to not be inherited on the interface. Defaults Not configured. Command Modes ROUTER OSPFv3 Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.4.2.
Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Added support for VRF. 9.1.(0.0) Introduced on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for C-Series. 7.4.1.0 Introduced on the E-Series.
Example Lines Beginning With or Including Description OSPFv3... Debugging is on for all OSPFv3 packets and all interfaces. 05:21:01 Displays the time stamp. Sending Ver:3 Sending OSPF3 version..
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Command Fields Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for C-Series. 7.4.1.0 Introduced on E-Series.
default-information originate Configure the Dell Networking OS to generate a default external route into an OSPFv3 routing domain. Syntax default-information originate [always] [metric metric-value] [metric-type type-value] [route-map map-name] To return to the default values, use the no default-information originate command. Parameters always (OPTIONAL) Enter the keyword always to specify that default route information must always be advertised.
Parameters seconds Time duration, in seconds, that specifies the duration of the restart process before OSPFv3 terminates the process. The range is from 40 to 1800 seconds. Defaults OSPFv3 graceful restart is disabled and functions in a helper-only role. Command Modes ROUTER OSPFv3 Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.4.2.2 Introduced on the E-Series TeraScale. 8.3.19.0 Introduced on the S4820T. OSPFv3 graceful restart supports planned-only and/or unplanned-only restarts. The default is support for both planned and unplanned restarts.
Parameters null Causes an authentication policy configured for the area to not be inherited on the interface. ipsec spi number Security Policy index (SPI) value that identifies an IPsec security policy. The range is from 256 to 4294967295. MD5 | SHA1 Authentication type: Message Digest 5 (MD5) or Secure Hash Algorithm 1 (SHA-1). key-encryptiontype (OPTIONAL) Specifies if the key is encrypted. Valid values: 0 (key is not encrypted) or 7 (key is encrypted). key Text string used in authentication.
ipv6 ospf cost Explicitly specify the cost of sending a packet on an interface. Syntax ipv6 ospf interface-cost Parameters interface-cost Enter a unsigned integer value expressed as the link-state metric. The range is from 1 to 65535. Defaults Default cost based on the bandwidth. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Defaults 40 seconds (Ethernet). Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 7.8.1.0 Added support for C-Series. 7.4.1.0 Introduced on the E-Series. 8.3.19.0 Introduced on the S4820T.
authenticationalgorithm Specifies the authentication algorithm to use for encryption. Valid values are MD5 or SHA1. key-encryptiontype (OPTIONAL) Specifies if the authentication key is encrypted. Valid values: 0 (key is not encrypted) or 7 (key is encrypted). key Text string used in authentication. For MD5 authentication, the key must be 32 hex digits (non-encrypted) or 64 hex digits (encrypted). For SHA-1 authentication, the key must be 40 hex digits (non-encrypted) or 80 hex digits (encrypted).
ipv6 ospf graceful-restart helper-reject Configure an OSPFv3 interface to not act upon the Grace LSAs that it receives from a restarting OSPFv3 neighbor. Syntax ipv6 ospf graceful-restart helper-reject To disable the helper-reject role, enter no ipv6 ospf graceful-restart helper-reject. Defaults The helper-reject role is not configured. Command Modes INTERFACE Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 7.8.1.0 Added support for the C-Series. 7.4.1.0 Introduced on the E-Series. 8.3.19.0 Introduced on the S4820T. Usage Information The time interval between hello packets must be the same for routers in a network. Related Commands ipv6 ospf dead-interval – specifies the time interval between hello packets was received from a router.
To exit OSPF for IPv6, use the no ipv6 router ospf process-id command. Parameters process-id Enter the process identification number. The range is from 1 to 65535. vrf vrf-name (Optional) Enter the keyword vrf followed by the name of the VRF to install IPv6 routes in that VRF. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
max-metric router-lsa Configure the maximum cost of 65535 on a new router so that it functions as a stub router in the network and OSPF traffic destined to other networks is not forwarded on a path through the router.
Example max-metric router-lsa Dell(conf)#router ospf 10 Dell(conf-router_ospf)#log-adjacency-changes Dell(conf-router_ospf)#network 4.1.1.0/24 area 0 Dell(conf-router_ospf)#network 1.1.1.0/24 area 1 Dell(conf-router_ospf)#max-metric router-lsa on-startup wait-for-bgp Dell(conf-router_ospf)#exit Dell(conf)#show ip ospf Routing Process ospf 10 with ID 100.1.1.
• For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. Defaults Enabled, that is sending of routing updates are enabled by default. Command Modes ROUTER OSPF for OSPFv2 ROUTER OSPFv3 for OSPFv3 Command History Usage Information Version Description 9.1.(0.0) Introduced support for OSPFv3 on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for the C-Series. 7.4.1.0 Introduced on the E-Series. By default, no interfaces are passive.
The range is from 0 to 16777214. The default is 20. metric-type typevalue (OPTIONAL) Enter the keywords metric-type then the OSPFv3 link state type of 1 or 2 for default routes. The values are: • 1 for a type 1 external route • 2 for a type 2 external route The default is 2. route-map mapname (OPTIONAL) Enter the keywords route-map then the name of an established route map. If the route map is not configured, the default is deny (to drop all routes).
router-id Designate a fixed router ID. Syntax router-id ip-address To return to the previous router ID, use the no router-id ip-address command. Parameters ip-address Enter the router ID in the dotted decimal format. Defaults The router ID is selected automatically from the set of IPv4 addresses configured on a router. Command Modes ROUTER OSPF for OSPFv2 ROUTER OSPFv3 for OSPFv3 Command History This guide is platform-specific.
EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.4.2.0 Introduced on the E-Series TeraScale. 8.3.19.0 Introduced on the S4820T.
show crypto ipsec policy Command Fields Field Description Policy name Displays the name of an IPsec policy. Policy refcount Number of interfaces on the router that use the policy. Inbound ESP SPI The encapsulating security payload (ESP) security policy index (SPI) for inbound and outbound links. Outbound ESP SPI Inbound ESP Auth Key The ESP authentication key for inbound and outbound links. Outbound ESP Auth Key Inbound ESP Cipher Key The ESP encryption key for inbound and outbound links.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.1.(0.0) Introduced on the S4810 and Z9000. 8.4.2.0 Introduced on the E-Series TeraScale. 8.3.19.0 Introduced on the S4820T.
replay detection support : N STATUS : ACTIVE show crypto ipsec sa ipv6 Command Fields Field Description Interface IPv6 interface Link local address IPv6 address of interface IPSecv6 policy name Name of the IPsec security policy applied to the interface. inbound/outbound ah Authentication policy applied to inbound or outbound traffic. inbound/outbound esp Encryption policy applied to inbound or outbound traffic. spi Security policy index number used to identify the policy.
Command Modes EXEC EXEC Privilege Command History Version Description 9.7(0.0) Added support for VRF. 9.1.(0.0) Added support for OSPFv3 on the S4810 and Z9000. 8.4.2.2 Added support for the display of graceful restart parameters and Type-11 Grace LSAs on E-Series TeraScale routers. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for C-Series.
Inter Area Pfx LSA Count 1 Inter Area Rtr LSA Count 0 Group Mem LSA Count 0 Type-7 LSA count 0 Intra Area Pfx LSA Count 2 Intra Area TE LSA Count 2 Area 1 database summary Type Count/Status Brd Rtr Count 1 AS Bdr Rtr Count 1 LSA count 8 Rtr LSA Count 1 Net LSA Count 0 Inter Area Pfx LSA Count 5 Inter Area Rtr LSA Count 0 Group Mem LSA Count 0 Type-7 LSA count 0 Intra Area Pfx LSA Count 2 Intra Area TE LSA Count 2 E1200-T2C2#sh ipv6 ospf neighbor Neighbor ID Interface 63.114.8.
Command History Usage Information Version Description 9.2.(0.0) Added support for showing BFD status on the S4820T, S4810, and Z9000. 9.1.(0.0) Added support for OSPFv3 on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for the C-Series. 7.4.1.0 Introduced on the E-Series. If you enable BFD at the global level, show ipv6 ospf interface shows the BFD provisioning. If you enable BFD at the interface level, show ipv6 ospf interface shows the BFD interval timers.
Command Modes EXEC EXEC Privilege Command History Example Version Description 9.7(0.0) Added support for VRF. 9.1.(0.0) Introduced support for OSPFv3 on the S4810 and Z9000. 8.3.19.0 Introduced on the S4820T. 7.8.1.0 Added support for the C-Series. 7.4.1.0 Introduced on the E-Series. Dell#show ipv6 ospf 3 neighbor gi 1/2 Neighbor ID 63.114.8.
37 Policy-based Routing (PBR) Policy-based routing (PBR) allows you to apply routing policies to specific interfaces. To enable PBR, create a redirect list and apply it to the interface. After the redirect list is applied to the interface, all traffic passing through the interface is subject to the rules defined in the redirect list. PBR is supported by the Dell Networking Operating System (OS).
ip redirect-group Apply a redirect list (policy-based routing) on an interface. You can apply multiple redirect lists to an interface by entering this command multiple times. Syntax ip redirect-group redirect-list-name To remove a redirect list from an interface, use the no ip redirect-group name command. Parameters redirect-list-name Enter the name of a configured redirect list. Defaults none Command Modes INTERFACE (conf-if-vl-) Command History Usage Information Version Description 9.7(0.
Parameters redirect-list-name Defaults None Command Modes CONFIGURATION Command History Enter the name of a redirect list. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.2.0 Introduced on the E-Series Tera Scale. 7.7.1.0 Introduced on the E-Series ExaScale. permit Configure a permit rule.
operator Defaults none Command Modes REDIRECT-LIST Command History • ack = acknowledgement • fin = finish (no more data from the user) • psh = push function • rst = reset the connection • syn = synchronize sequence number • urg = urgent field (OPTIONAL) For TCP and UDP parameters only.
ip-address Enter the IP address of the forwarding router. slot/port Enter the keyword slot / port followed by the slot/port information. tunnel Enter the keyword tunnel to configure the tunnel setting. tunnel-id Enter the keyword tunnel-id to redirect the traffic. track Enter the keyword track to enable the tracking. track Enter the keyword track to track object-id. ip-protocol-number Enter a number from 0 to 255 for the protocol identified in the IP protocol header.
Version Description 9.7(0.0) Added support for the track-id on the S4810, S4820T, S6000, and Z9000. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. 8.4.2.1 Introduced on the C-Series and S-Series. 8.4.2.0 Introduced on the E-Series Tera Scale. 7.7.1.0 Introduced on the E-Series ExaScale. seq Configure a filter with an assigned sequence number for the redirect list.
host ip-address Enter the keyword host then the IP address to specify a host IP address. destination Enter the IP address of the network or host to which the packets are sent.
show cam pbr Display the PBR CAM content. Syntax show cam pbr {[interface interface] | stack—unit slot-number port-set number]} [summ Parameters interface interface Enter the keyword interface then the name of the interface. stack–unit number Enter the keyword stack-unit then the slot number. port-set number Enter the keywords port-set then the port-pipe number. summary Enter the keyword summary to view only the total number of CAM entries.
Parameters Command Modes Command History Example redirect-list-name • EXEC • EXEC Privilege Enter the name of a configured Redirect list. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. Dell#show ip redirect-list explicit_tunnel IP redirect-list explicit_tunnel: Defined as: seq 5 redirect tunnel 1 track 1 tcp 155.55.2.0/24 222.22.2.
38 PIM-Sparse Mode (PIM-SM) The protocol-independent multicast (PIM) commands are supported by the Dell Networking operating software on the platform. IPv4 PIM-Sparse Mode Commands The following describes the IPv4 PIM-sparse mode (PIM-SM) commands. clear ip pim rp-mapping The bootstrap router (BSR) feature uses this command to remove all or particular rendezvous point (RP) advertisement.
Usage Information This command re-applies the RP mapping logic for all the groups learnt by the node. Any stale information corresponding to the existing mapping configuration is updated. As a result, the existing BSR cache and the *,G's are deleted only if these entries are stale. clear ip pim tib Clear PIM tree information from the PIM database.
debug ip pim View IP PIM debugging messages. Syntax debug ip pim [vrf vrf-name] [bsr | events | group | packet [in | out] | register | state | timer [assert | hello | joinprune | register]] To disable PIM debugging, use the no debug ip pim [vrf vrf-name] command or use the undebug allto disable all debugging command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to view IP PIM debugging messages corresponding to that VRF.
Version Description 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.12.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series. ip pim bsr-border Define the border of PIM domain by filtering inbound and outbound PIM-BSR messages per interface. Syntax ip pim bsr-border To return to the default value, use the no ip pim bsr-border command.
Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure the PIM router on a VRF. interface Enter the following keywords and slot/port or number information: • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128.
Defaults 1 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Version Description 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series for the port-channels and the S-Series. 7.7.1.0 Introduced on the E-Series. Example Dell(conf)# ip access-list extended iptv-channels Dell(config-ext-nacl)# permit ip 10.1.2.3/24 225.1.1.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series and S-Series. 7.6.1.0 Introduced on the E-Series. Do not enter this command before creating the access-list. ip pim query-interval Change the frequency of PIM Router-Query messages. Syntax ip pim query-interval seconds To return to the default value, use the no ip pim query-interval seconds command.
To return to the default, use the no ip pim [vrf vrf-name] register-filter access-list command. Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. access-list Enter the name of an extended access list. Maximum 16 characters. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
group-address group-address mask Enter the keywords group-address then a group-address mask, in dotted decimal format (/xx), to assign that group address to the RP. override Enter the keyword override to override the BSR updates with static RP. The override takes effect immediately during enable/disable. NOTE: This option is applicable to multicast group range. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
priority • For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a VLAN, enter the keyword vlan then a number from 1 to 4094.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series for the port-channels and the S-Series. The interface must be enabled (the no shutdown command) and not have the switchport command configured.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the C-Series for the port-channels and the S-Series. 7.7.1.1 Introduced This command configures an expiration timer for all S.G entries, unless they are assigned to an Extended ACL.
Usage Information Dell Networking OS supports standard access lists for the SSM range. You cannot use extended ACLs for configuring the SSM range. If you configure an extended ACL and then used in the ip pim ssm-range {access list name} configuration, an error is reported. However, if you configure ip pim ssm-range {access list name} first and then you configure the ACL as an Extended ACL, an error is not reported and the ACL is not applied to the SSM range.
Usage Information Version Description 8.1.1.0 Introduced on the E-Series ExaScale. This command is applicable to last hop routers on the shared tree towards the rendezvous point (RP). show ip pim bsr-router View information on the Bootstrap router. S6000–ON Syntax show ip pim [vrf vrf-name] bsr-router Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.12.
show ip pim neighbor View PIM neighbors. S6000–ON Syntax show ip pim [vrf vrf-name] neighbor Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.
Address 127.87.3.4 Te 1/16/1 Dell# 09:44:58/00:01:24 v2 Prio/Mode 1 / S show ip pim rp View all multicast groups-to-RP mappings. S6000–ON Syntax Parameters Command Modes Command History show ip pim [vrf vrf-name] rp [mapping | group-address] vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. mapping (OPTIONAL) Enter the keyword mapping to display the multicast groups-to-RP mapping and information on how RP is learnt.
RP: 50.40.4.4, v2 Dell# Example (Address) Dell#show ip pim rp 229.1.2.1 Group RP 229.1.2.1 165.87.20.4 show ip pim ssm-range Display the non-default groups added using the SSM range feature. S6000–ON Syntax show ip pim [vrf vrf-name] ssm-range Defaults none Command Modes Command History Exmaple • EXEC • EXEC Privilege Version Description 9.7(0.0) Introduced on the S6000-ON. Added support for VRF on S6000, S4810, S4820T, Z9000, Z9500, and S6000–ON. 9.5(0.0) Introduced on the Z9500. 9.0.2.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Added support for VRF. Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.4.1.1 Support for the display of PIM-SM snooping status was added on E-Series ExaScale. 8.1.1.0 Introduced on the E-Series ExaScale. 7.8.1.0 Introduced on the S-Series.
show ip pim tib View the PIM tree information base (TIB). S6000–ON Syntax show ip pim [vrf vrf-name] tib [group-address [source-address]] Parameters vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name of the VRF to configure this setting on that VRF. NOTE: Applies to specific VRF if input is provided, else applies to Default VRF. Command Modes Command History group-address (OPTIONAL) Enter the group address in dotted decimal format (A.B.C.D).
Field Example Description • C = directly connected • L = local to the multicast group • P = route was pruned • R = the forwarding entry is pointing toward the RP • F = Dell Networking OS is registering this entry for a multicast source • T = packets were received via Shortest Tree Path • J = first packet from the last hop router is received and the entry is ready to switch to SPT • K = acknowledge pending state Incoming interface Displays the reverse path forwarding (RPF) interface toward
39 Port Monitoring The port monitoring feature allows you to monitor network traffic by forwarding a copy of each incoming or outgoing packet from one port to another port. Important Points to Remember • Port monitoring is supported on physical ports and logical interfaces, such as port channels and virtual local area networks (VLANs). • The monitoring (destination, “MG”) and monitored (source, “MD”) ports must be on the same switch.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-7.7.1.0 Introduced on the E-Series. monitor session — enables a monitoring session. monitor session Create a session for monitoring traffic with port monitoring.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. Introduced the set ip dscp and set ip ttl parameters. 9.5(0.0) Introduced on the Z9500. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. 9.0.2.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.3.11.1 Introduced on the Z9000. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series.
Example Version Description 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. Dell#show monitor session 1 SessID Source Destination Dir Mode Source IP ------ ------ ----------- --- ---- --------1 Te 1/2/1 remote-ip rx Port 0.0.0.0 0.0.0.0 Dell#show monitor session SessID Source Destination Dir Mode Source IP ------ ------ ----------- --- ---- --------1 Te 1/2/1 remote-ip rx Port 0.0.0.0 0.0.0.
Version Description 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Introduced on the E-Series. Usage Information The monitoring command is saved in the running configuration at the Monitor Session mode level and can be restored after a chassis reload. Example Dell# show running-config monitor session ! monitor session 1 source TenGigabitEthernet 1/1/1 destination TenGigabitEthernet 1/2 direction rx Related Commands monitor session — creates a monitoring session.
direction {rx | tx | both} • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. • For a VLAN interface, enter the keyword vlan then a number from 1 to 4094. • For a port channel interface, enter the keywords port-channel then a number. Enter the keyword direction then one of the packet directional indicators. • rx: to monitor receiving packets only. • tx: to monitor transmitting packets only.
40 Private VLAN (PVLAN) The private VLAN (PVLAN) feature of the Dell Networking operating software is supported on the platforms. Private VLANs extend the Dell Networking OS security suite by providing Layer 2 isolation between ports within the same private VLAN. A private VLAN partitions a traditional VLAN into subdomains identified by a primary and secondary VLAN pair. The Dell Networking OS private VLAN implementation is based on RFC 3069. For more information, refer to the following commands.
– A trunk port in a PVLAN is always tagged. – A trunk port in Tagged mode carries primary or secondary VLAN traffic. The tag on the packet helps identify the VLAN to which the packet belongs. – A trunk port can also belong to a regular VLAN (non-private VLAN). ip local-proxy-arp Enable/disable Layer 3 communication between secondary VLANs in a private VLAN.
private-vlan mode Set PVLAN mode of the selected VLAN to community, isolated, or primary. S6000–ON Syntax [no] private-vlan mode {community | isolated | primary} To remove the PVLAN configuration, use the no private-vlan mode {community | isolated | primary} command syntax. Parameters community Enter the keyword community to set the VLAN as a community VLAN. isolated Enter the keyword isolated to configure the VLAN as an isolated VLAN.
private-vlan mapping secondary-vlan Map secondary VLANs to the selected primary VLAN. S6000–ON Syntax [no] private-vlan mapping secondary-vlan vlan-list To remove specific secondary VLANs from the configuration, use the no private-vlan mapping secondary-vlan vlan-list command syntax. Parameters vlan-list Enter the list of secondary VLANs to associate with the selected primary VLAN. The list can be in comma-delimited or hyphenated-range format, following the convention for the range input.
switchport mode private-vlan Set PVLAN mode of the selected port. S6000–ON Syntax [no] switchport mode private-vlan {host | promiscuous | trunk} To remove PVLAN mode from the selected port, use the no switchport mode private-vlan command. Parameters host Enter the keyword host to configure the selected port or port channel as an isolated interface in a PVLAN. promiscuous Enter the keyword promiscuous to configure the selected port or port channel as an promiscuous interface.
Related Commands private-vlan mode — sets the mode of the selected VLAN to community, isolated, or primary. private-vlan mapping secondary-vlan — sets the mode of the selected VLAN to primary and then associates the secondary VLANs to it.
41 Per-VLAN Spanning Tree Plus (PVST+) The Dell Networking operating software implementation of per-VLAN spanning tree plus (PVST+) is based on the IEEE 802.1w standard spanning tree protocol. Dell Networking OS supports PVST+ on the S6000–ON platform. NOTE: For easier command line entry, the plus (+) sign is not used at the command line. description Enter a description of the PVST+. S6000–ON Syntax description {description} To remove the description, use the no description {description} command.
disable Disable PVST+ globally. S6000–ON Syntax disable To enable PVST+, use the no disable command. Defaults Disabled. Command Modes CONFIGURATION (conf-pvst) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced. Dell(conf-pvst)#do show spanning-tree pvst vlan 5 brief VLAN 5 Executing IEEE compatible Spanning Tree Protocol Root ID Priority 32773, Address 0001.e832.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 8.3.1.0 Introduced.
• guard Defaults Command Modes Command History For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. (OPTIONAL) Enter the keyword guard to display the type of guard enabled on a PVST interface and the current port state. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ---------------------------------------------------------Te 1/0/1 128.130 128 20000 FWD 20000 4096 0001.e801.6aa8 Te 1/1/1 128.131 128 20000 BLK 20000 4096 0001.e801.6aa8 Te 1/16/1 128.146 128 20000 FWD 20000 16384 0001.e805.e306 Te 1/17/1 128.147 128 20000 FWD 20000 16384 0001.e805.e306 128.426 128.427 128.146 128.
Bpdu guard :disable (default) Bpdus sent 152, received 27562 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ----------------------------------------------------------Te 1/1/1 128.1223 128 20000 EDS 0 32768 0001.e800.a12b 128.
vlan vlan-range Enter the keyword vlan then the VLAN numbers. The range is from 1 to 4094. cost number Enter the keyword cost then the port cost value. The range is from 1 to 200000. Defaults: • 100 Mb/s Ethernet interface = 200000. • 1-Gigabit Ethernet interface = 20000. • 10-Gigabit Ethernet interface = 2000. • Port Channel interface with one 100 Mb/s Ethernet = 200000. • Port Channel interface with one 1 Gigabit Ethernet = 20000. • Port Channel interface with one 10 Gigabit Ethernet = 2000.
Usage Information The BPDU guard option prevents the port from participating in an active STP topology in case a BPDU appears on a port unintentionally, or is misconfigured, or is subject to a DOS attack. This option places the port into the Error Disable state if a BPDU appears, and a message is logged so that the administrator can take corrective action. NOTE: A port configured as an edge port, on a PVST switch, immediately transitions to the forwarding state.
Defaults Enabled; ports are placed in the Err-Disabled state if they receive a PVST+ BPDU when they are members of an untagged VLAN. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.5.1.0 Introduced. By default, Dell Networking OS implements an optimized flush mechanism for PVST+.
Related Commands Version Description 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced. vlan forward-delay — changes the time interval before Dell Networking OS transitions to the Forwarding state. vlan hello-time — change the time interval between BPDUs. vlan max-age — changes the time interval before PVST+ refreshes. show spanning-tree pvst — displays the PVST+ configuration.
Related Commands Version Description 6.2.1.1 Introduced. vlan bridge-priority — sets the bridge-priority value. vlan hello-time — changes the time interval between BPDUs. vlan max-age — changes the time interval before PVST+ refreshes. show spanning-tree pvst — displays the PVST+ configuration. vlan hello-time Set the time interval between generation of PVST+ 7 BPDUs. S6000–ON Syntax vlan vlan-range hello-time seconds To return to the default value, use the no vlan hello-time command.
Related Commands vlan bridge-priority — sets the bridge-priority value. vlan forward-delay — changes the time interval before Dell Networking OS transitions to the forwarding state. vlan max-age — changes the time interval before PVST+ refreshes. show spanning-tree pvst — displays the PVST+ configuration. vlan max-age To maintain configuration information before refreshing that information, set the time interval for the PVST+ bridge.
vlan forward-delay — changes the time interval before Dell Networking OS transitions to the forwarding state. vlan hello-time — changes the time interval between BPDUs. show spanning-tree pvst — displays the PVST+ configuration.
42 Quality of Service (QoS) The Dell Networking operating software commands for quality of service (QoS) include traffic conditioning and congestion control. QoS commands are not universally supported on all Dell Networking Products. platform. This chapter contains the following sections: • Global Configuration Commands • Per-Port QoS Commands • Policy-Based QoS Commands Global Configuration Commands There is only one global configuration QoS command.
Version Description 8.3.1.0 Introduced. service-class bandwidth-percentage Specify a minimum bandwidth for queues. S6000–ON Syntax Parameters service-class bandwidth-percentage queue0 number queue1 number queue2 number queue3 number number Defaults none Command Modes CONFIGURATION Command History Usage Information Enter the bandwidth-weight, as a percentage. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
strict-priority queue Configure a unicast queue as a strict-priority (SP) queue. S6000–ON Syntax Parameters strict-priority queue unicast number unicast number Enter the keyword unicast then the queue number. The range is from 1 to 3. Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.5.1.0 Introduced on the C-Series. pre- 6.1.1.1 Introduced on the E-Series. The dot1p-priority command changes the priority of incoming traffic on the interface.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information NOTE: Per Port rate police is supported for Layer 2 tagged and untagged switched traffic and for Layer 3 traffic. Per VLAN rate police is supported on only tagged ports with Layer 2 switched traffic.
Usage Information On 40-port 10G stack-unit if the traffic is shaped between 64 and 1000 Kbs, for some values, the shaped rate is much less than the value configured. NOTE: When packets of size greater than 7000 bytes are expected to be received from the network, Dell Networking recommends that you configure the burst value to be more than 175 KB if you configured the rate shape. Such a setting ensures proper bandwidth sharing across queues.
Usage Information To honor all incoming 802.1p markings on incoming switched traffic on the interface, enter this command. By default, this facility is not enabled (that is, the 802.1p markings on incoming traffic are not honored). You can apply this command on both physical interfaces and port channels.
Usage Information The unit of bandwidth percentage is 1%. If the sum of the bandwidth percentages given to all eight classes exceeds 100%, the bandwidth percentage automatically scales down to 100%. Related Commands qos-policy-output — creates a QoS output policy. buffer-stats-snapshot Enable the buffer statistics tracking utility and enter the Buffer Statistics Snapshot configuration mode. You must enable this utility to be able to configure the parameters for buffer statistics tracking.
match-any Determines how packets are evaluated when multiple match criteria exist. Enter the keywords match-any to determine that the packets must meet at least one of the match criteria in order to be a member of the class. class-map-name Enter a name of the class for the class map in a character format (32 character maximum). cpu-qos Enter the keyword cpu-qos to assign this Class Map to control plane traffic only (CoPP). layer2 Enter the keyword layer2 to specify a Layer 2 Class Map.
match mac vlan — configures a match criterion for a class map based on VLAN ID. service-queue — assigns a class map and QoS policy to different queues. show qos class-map — views the current class map information. clear qos statistics Clear qos statistics clears statistics from show qos statistics.
Parameters description Enter a description to identify the policies (80 characters maximum). Defaults none Command Modes CONFIGURATION (policy-map-input and policy-map-output; conf-qos-policy-in and conf-qos-policy-out; wred) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
set-color value (Optional) Enter the keyword set-color followed by a color value. Traffic that fulfills the match criteria is marked with the color value that you specify. The default value is Yellow. Defaults none Command Modes CLASS-MAP CONFIGURATION (config-class-map) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Added the ipv6 and ip-any options on the Z9000, S6000, S4820T, S4810, MXL. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Command Modes CLASS-MAP CONFIGURATION (config-class-map) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Added support for the ipv6 and ip-any options on the Z9000, S6000, S4820T, S4810, MXL. 9.2(1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information To access this command, enter the class-map command. After the class map is identified, you can configure the match criteria. Related Commands class-map — identifies the class map. match mac dot1p Configure a match criterion for a class map based on a dot1p value.
Parameters number Enter the VLAN ID. The range is from 1 to 4094. Defaults none Command Modes CLASS-MAP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Version Description 8.3.7.0 Introduced on the S4810. Usage Information If the rate shape exists in both aggregate and per-queue qos-policy, minimum of 2 take effect. Some of all Queue-rate will not exceed aggregate. Related Commands policy-map-input — creates an input policy map. policy-map-output — creates an output policy map. policy-map-input Create an input policy map.
policy-map-output Create an output policy map. S6000–ON Syntax policy-map-output policy-map-name To remove a policy map, use the no policy-map-output policy-map-name command. Parameters policy-map-name Enter the name for the policy map in character format (32 characters maximum). Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
layer2 (OPTIONAL) Enter the keyword layer2 to specify a Layer 2 Class Map. The default is Layer 3. Defaults Layer 3 Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. Usage Information Use this command to specify the name of the output QoS policy. Once output policy is specified, rateshape, scheduler strict, bandwidth-percentage, and WRED can be defined. This command enables the qospolicy-output configuration mode—(conf-qos-policy-out).
Version Description 8.3.7.0 Introduced on the S4810. Usage Information The default burst size is 100Kb. If a different value is required, you must configure the burst size to the required value. Related Commands rate police — specifies traffic policing on the selected interface. qos-policy-input — creates a QoS output policy. rate-shape Shape traffic output as part of the designated policy.
service-policy input Apply an input policy map to the selected interface. S6000–ON Syntax service-policy input policy-map-name [layer2] To remove the input policy map from the interface, use the no service-policy input policymap-name [layer2] command. Parameters policy-map-name Enter the name for the policy map in character format (32 characters maximum). You can identify an existing policy map or name one that does not yet exist.
Parameters policy-map-name Enter the name for the policy map in character format (32 characters maximum). You can identify an existing policy map or name one that does not yet exist. Defaults none Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Usage Information After the IP DSCP bit is set, other QoS services can then operate on the bit settings. show qos class-map View the current class map information. S6000–ON Syntax Parameters Defaults Command Modes Command History show qos class-map [class-name] class-name (Optional) Enter the name of a configured class map. none • EXEC • EXEC Privilege This guide is platform-specific.
detail Defaults To view a policy map interface in detail, enter the keyword detail and optionally one of the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
7 Dell# Example (Summary IPv4) c7 q7 Dell#sho qos policy-map summary Interface policy-map-input policy-map-output Te 4/1/1 PM1 Te 4/2/1 PM2 PMOut Dell# show qos policy-map-input View the input QoS policy map details. S6000–ON Syntax Parameters Defaults Command Modes Command History show qos policy-map-input [policy-map-name] [class class-map-name] [qospolicy-input qos-policy-name] policy-map-name Enter the policy map name. class class-mapname Enter the keyword class then the class map name.
show qos policy-map-output View the output QoS policy map details. S6000–ON Syntax show qos policy-map-output [policy-map-name] [qos-policy-output qos-policyname] Parameters Defaults policy-map-name Enter the policy map name. qos-policy-output qos-policy-name Enter the keyword qos-policy-output then the QoS policy name. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific.
• Command History EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
Example Dell#show qos qos-policy-output Qos-policy-output qosOut Rate-limit 50 50 peak 50 50 Wred yellow 1 Wred green 1 show qos statistics View QoS statistics.
show qos wred-profile View the WRED profile details. S6000–ON Syntax Parameters Defaults Command Modes Command History show qos wred-profile wred-profile-name wred-profile-name Enter the WRED profile name to view the profile details. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
number Enter a weight for the queue on the shared buffer as a number in the range of 1 to 11. Default The default threshold weight on the shared buffer for each queue is 9. Therefore, each queue can consume up to 66.67 percent of available shared buffer by default. Command Modes INTERFACE mode Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Introduced on the S6000 platform You can configure all the data queues.
test cam-usage Check the Input Policy Map configuration for the CAM usage. S6000–ON Syntax Parameters test cam-usage service-policy input policy-map stack-unit {[number port-set portpipe number] | [all]} policy-map Enter the policy map name. stack-unitnumber (OPTIONAL) Enter the keyword stack-unit then the stack-unit slot number. port-set portpipe number Enter the keywords port-set then the stack-unit port pipe number. The range is from 0 or 1.
Field Description NOTE: The CAM entries reserved for the default rules are not included in the Available CAM column; free entries, from the default rules space, cannot be used as a policy map for the classification rules. Estimated CAM per Port Indicates the number of free CAM entries required (for the classification rules) to apply the input policy map on a single interface.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.8.0 Introduced on the S4810.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. When you configure trust, matched bytes/packets counters are not incremented in the show qos statistics command. Dynamic mapping honors packets marked according to the standard definitions of DSCP. The following lists the default mapping.
profile-name Enter your WRED profile name in character format (32 character maximum). Or use one of the five pre-defined WRED profile names. Pre-defined Profiles: wred_drop, wred-ge_y, wred_ge_g, wred_teng_y, wred_teng_. Defaults When WRED green is applied, default WRED yellow profiles take effect and vice-versa. Command Modes CONFIGURATION (conf-qos-policy-out) Command History This guide is platform-specific.
Usage Information Version Description 8.3.19.0 Introduced on the S4820t. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. When you enable wred ecn, and the number of packets in the queue is below the minimum threshold, packets are transmitted per the usual WRED treatment.
the packet is taken based on the packet drop probability. The probability that a packet is dropped depends on the minimum threshold, maximum threshold, and mark probability denominator. Example FTOS (conf-qos-policy-out) # wred weight 5 wred-profile Create a WRED profile and name the profile. S6000–ON Syntax wred-profile wred-profile-name To remove an existing WRED profile, use the no wred-profile command.
rate shape Define the rate-shaping method to be either as a measure of bytes or packets for each of the hierarchical QoS (HQoS) nodes at the leaf level to be applied to each queue. S6000–ON Syntax [no] rate-shape [kbps | pps] peak-rate [burst-KB/Packets] [committed [kbps | pps] committed-rate [burst-KB/Packets]] Parameters 1098 kbps Enter the keyword kbps to specify the committed rate limit in Kilobits per second (Kbps). Specify this value as a multiple of 64. The range is from 0 to 40000000.
Default Granularity for rate is Mbps unless you use the kbps option. Command Modes CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.0) Added support for committed rate and committed burst size, and for configuration of rate limits on the S6000 platform. If you specify the pps keyword after the rate-shape command, the peak rate, peak burst, committed rate and committed burst are all considered to be values as a measure of packets.
yellow Specify yellow (medium) drop precedence to a queue. pool0 Service-pool buffer 1 (default service-pool for PFC traffic) . pool1 Service-pool buffer 0 (default service-pool for lossy traffic). number Enter a weight for the queue as a number in the range of 1 to 15. This parameter applies only if you specify the green or yellow drop precedence. string Enter the WRED profile name. It is a string of up to 32 characters. Or use one of the five pre-defined WRED profile names.
DSCP Color Map Commands The DSCP color map allows you to set the number of specific DSCP values to yellow or red. Traffic marked as yellow delivers traffic to the egress queue which will either transmit the packet if it has available bandwidth or drop the packet due to no ability to send. Traffic marked as red (high drop precedence) is dropped. dscp Sets the number of specific DSCP values for a color map profile to yellow or red.
Example Dell(conf-dscp-color-map)# dscp yellow 9,10,11,13,15,16 Related Commands qos dscp-color-map — configures the DSCP color map qos dscp-color-policy— configures a DSCP color policy qos dscp-color-map Configure the DSCP color map. Syntax qos dscp-color-map map-name To remove a color map, use the no qos dscp-color-map map-name command. Parameters map-name Enter the name of the DSCP color map. The map name can have a maximum of 32 characters.
To remove a color policy map profile, use the no dscp-color-policy color-map-profile-name command. Parameters color-map-profilename Enter the color map profile name. The name can have a maximum of 32 characters. Defaults None Command Modes CONFIG-INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5.0.0 Introduced on the Z9000, S6000, S4820T, S4810, and MXL. Display summary information about a color policy on one or more interfaces. Dell# show qos dscp-color-policy summary Interface TE 1/10/1 TE 1/11/1 dscp-color-map mapONE mapTWO Display summary information about a color policy on a specific interface.
Dscp-color-map mapONE yellow 4,7 red 20,30 Dscp-color-map mapTWO yellow 16,55 Display a specific DSCP color map.
43 Routing Information Protocol (RIP) Routing information protocol (RIP) is a distance vector routing protocol. The Dell Networking operating software supports both RIP version 1 (RIPv1) and RIP version 2 (RIPv2) on the platform. The Dell Networking OS implementation of RIP is based on IETF RFCs 2453 and RFC 1058. For more information about configuring RIP, refer to the Dell Networking OS Configuration Guide.
clear ip rip Update all the RIP routes in the Dell Networking OS routing table. S6000–ON Syntax clear ip rip Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000.
database (OPTIONAL) Enter the keyword database to display messages when there is a change to the RIP database. events (OPTIONAL) Enter the keyword events to debug only RIP protocol changes. trigger (OPTIONAL) Enter the keyword trigger to debug only RIP trigger extensions. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Version Description 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information This command ensures that route information being redistributed is converted to the same metric value. Related Commands redistribute — allows you to redistribute routes learned by other methods. description Enter a description of the RIP routing protocol.
distance Assign a weight (for prioritization) to all routes in the RIP routing table or to a specific route. Lower weights (“administrative distance”) are preferred. S6000–ON Syntax distance weight [ip-address mask [prefix-name]] To return to the default values, use the no distance weight [ip-address mask] command. Parameters weight Enter a number from 1 to 255 for the weight (for prioritization). The default is 120. ip-address (OPTIONAL) Enter the IP address, in dotted decimal format (A.B.C.
To delete the filter, use the no distribute-list prefix-list-name in command. Parameters prefix-list-name Enter the name of a configured prefix list. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
Parameters prefix-list-name Enter the name of a configured prefix list. interface (OPTIONAL) Identifies the interface type slot/port as one of the following: • For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
ip poison-reverse Set the prefix of the RIP routing updates to the RIP infinity value. S6000–ON Syntax ip poison-reverse To disable poison reverse, use the no ip poison-reverse command. Defaults Disabled. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information To enable the interface to send both version of RIP packets, use the ip rip send version 1 2 command.
Related Commands Version Description pre- 6.2.1.1 Introduced on the E-Series. ip poison-reverse — sets the prefix for RIP routing updates. maximum-paths Set RIP to forward packets over multiple paths. S6000–ON Syntax maximum-paths number To return to the default values, use the no maximum-paths commands. Parameters number Enter the number of paths. The range is from 1 to 16. The default is 4 paths. Defaults 4 Command Modes ROUTER RIP Command History This guide is platform-specific.
To delete a neighbor setting, use the no neighbor ip-address command. Parameters ip-address Enter the IP address, in dotted decimal format, of a router with which to exchange information. Defaults Not configured. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
Defaults Not configured. Command Modes ROUTER RIP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. This command is intended for low-speed interfaces. passive-interface Suppress routing updates on a specified interface.
Version Description 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information Although the passive interface does not send or receive routing updates, the network on that interface still includes in RIP updates sent using other interfaces. Related Commands neighbor — enables RIP for a specified network.
Version Description 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. Usage Information To redistribute the default route (0.0.0.0/0), configure the default-information originate command. Related Commands default-information originate — generates a default route for RIP traffic. redistribute isis Redistribute routing information from an IS-IS instance.
Version Description pre- 6.2.1.1 Introduced on the E-Series. redistribute ospf Redistribute routing information from an OSPF process. S6000–ON Syntax redistribute ospf process-id [match external {1 | 2} | match internal | metric metric-value] [route-map map-name] To disable redistribution, use the no redistribute ospf process-id [match external {1 | 2} | match internal | metric metric-value] [route-map map-name] command.
router rip To configure and enable RIP, enter ROUTER RIP mode. S6000–ON Syntax router rip To disable RIP, use the no router rip command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.
Usage Information Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. pre- 6.2.1.1 Introduced on the E-Series. The following describes the show ip rip database command shown in the following example. Field Description Total number of routes in RIP database Displays the number of RIP routes stored in the RIP database. 100.10.10.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.
flush Defaults Enter the number of seconds to specify the time interval during which the route is advertised as unreachable. When this interval expires, the route is flushed from the routing table. The flush value should be greater than the update value. The range is from zero (0) to 4294967295. The default is 240 seconds. • update = 30 seconds • invalid = 180 seconds • holddown = 180 seconds • flush = 240 seconds Command Modes ROUTER RIP Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the S-Series.
44 Remote Monitoring (RMON) The Dell Networking operating software remote monitoring (RMON) is implemented on the S6000–ON platform. Dell Networking OS RMON is based on IEEE standards, providing both 32-bit and 64-bit monitoring and long-term statistics collection.
interval Time, in seconds, the alarm monitors the MIB variables; this is the alarmSampleType in the RMON alarm table. The range is from 5 to 3600 seconds. delta Enter the keyword delta to test the change between MIB variables. This is the alarmSampleType in the RMON alarm table. absolute Enter the keyword absolute to test each MIB variable directly. This is the alarmSampleType in the RMON alarm table.
rmon collection history Enable the RMON MIB history group of statistics collection on an interface. S6000–ON Syntax rmon collection history {controlEntry integer} [owner name] [buckets number] [interval seconds] To remove a specified RMON history group of statistics collection, use the no rmon collection history {controlEntry integer} command. Parameters controlEntry integer Enter the keyword controlEntry to specify the RMON group of statistics using a value.
rmon collection statistics Enable RMON MIB statistics collection on an interface. S6000–ON Syntax rmon collection statistics {controlEntry integer} [owner name] To remove RMON MIB statistics collection on an interface, use the no rmon collection statistics {controlEntry integer} command. Parameters controlEntry integer Enter the keyword controlEntry to specify the RMON group of statistics using a value. Then enter an integer value from 1 to 65535 that identifies the RMON Statistic Table.
Parameters number Assign an event number in integer format. The range is from 1 to 65535. You must ensure that the value you enter is unique in the RMON event table. log (OPTIONAL) Enter the keyword log to generate an RMON event log. This option sets the eventType to either log or log-and-snmptrap in the RMON event table. The default is None. trap community (OPTIONAL) Enter the keyword trap followed by the SNMP community string to generate SNMP traps for an RMON event entry.
variable The MIB object to monitor. The variable must be in the SNMP OID format; for example, 1.3.6.1.2.1.1.3 The object type must be a 64-bit integer. interval Time, in seconds, the alarm monitors the MIB variables; this is the alarmSampleType in the RMON alarm table. The range is from 5 to 3600 seconds. delta Enter the keyword delta to test the change between MIB variables. This is the alarmSampleType in the RMON alarm table. absolute Enter the keyword absolute to test each MIB variable directly.
show rmon Display the RMON running status including the memory usage. S6000–ON Syntax show rmon Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
show rmon events Display the contents of the RMON event table. S6000–ON Syntax Parameters show rmon events [index] [brief] index (OPTIONAL) Enter the table index number to display just that entry. brief (OPTIONAL) Enter the keyword brief to display the RMON event table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
event owner: event status: OK RMON event entry 114 description: event type: LOG and SNMP TRAP. event community: public event last time sent: none event owner: event status: OK Example (Brief) Dell#show rmon event brief index description -----------------------------1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 Dell# show rmon hc-alarm Display the contents of RMON High-Capacity alarm table.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. Example (Index) Dell#show rmon hc-alarm 1 RMON high-capacity alarm entry 1 object: 1.3.6.1.2.1.1.3 sample interval: 5 sample type: absolute value.
Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
brief (OPTIONAL) Enter the keyword brief to display the RMON log table in an easyto-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
brief (OPTIONAL) Enter the keyword brief to display the RMON Ethernet statistics table in an easy-to-read format. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example (Index) 1144 Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
HC 512-1023 bytes packets: 0 HC 1024-1518 bytes packets overflow: 0 HC 1024-1518 bytes packets: 0 Dell# Example (Brief) Dell#show rmon statistics br index ifIndex interface ---------------------------------------6001 100974631 TenGigabitEthernet 2/2/1 6002 100974631 TenGigabitEthernet 2/2/1 6003 101236775 TenGigabitEthernet 2/1/1 6004 101236775 TenGigabitEthernet 2/1/1 9001 134529054 TenGigabitEthernet 3/2/1 9002 134529054 TenGigabitEthernet 3/2/1 9003 134791198 TenGigabitEthernet 3/1/1 9004 134791198 TenG
45 Rapid Spanning Tree Protocol (RSTP) The Dell Networking operating software implementation of rapid spanning tree protocol (RSTP) is based on the IEEE 802.1w standard spanning-tree protocol. The RSTP algorithm configures connectivity throughout a bridged local area network (LAN) that is comprised of LANs interconnected by bridges. Dell Networking OS supports RSTP.. bridge-priority Set the bridge priority for RSTP.
debug spanning-tree rstp Enable debugging of RSTP and view information on the protocol. Syntax debug spanning-tree rstp [all | bpdu interface {in | out} | events] To disable debugging, use the no debug spanning-tree rstp command. Parameters all (OPTIONAL) Enter the keyword all to debug all spanning tree operations. bpdu interface {in | out} (OPTIONAL) Enter the keyword bpdu to debug the bridge protocol data units.
description Enter a description of the rapid spanning tree. Syntax description {description} To remove the description, use the no description {description} command. Parameters description Enter a description to identify the rapid spanning tree (80 characters maximum). Defaults none Command Modes SPANNING TREE (The prompt is “config-rstp”.) Command History This guide is platform-specific.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. protocol spanning-tree rstp — enters SPANNING TREE mode on the switch. forward-delay Configure the amount of time the interface waits in the Listening State and the Learning State before transitioning to the Forwarding State.
hello-time Set the time interval between the generation of the RSTP bridge protocol data units (BPDUs). Syntax hello-time [milli-second] seconds To return to the default value, use the no hello-time command. Parameters seconds Enter a number as the time interval between transmission of BPDUs. The range is from 1 to 10 seconds. The default is 2 seconds. milli-second Enter the keywords milli-second to configure a hello time on the order of milliseconds.
max-age To maintain configuration information before refreshing that information, set the time interval for the RSTP bridge. Syntax max-age seconds To return to the default values, use the no max-age command. Parameters max-age Enter a number of seconds the Dell Networking OS waits before refreshing configuration information. The range is from 6 to 40 seconds. The default is 20 seconds.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information RSTP is not enabled when you enter RSTP mode.
no disable bridge-priority 16384 show spanning-tree rstp Display the RSTP configuration. Syntax Parameters Command Modes Command History Usage Information Example (Brief) show spanning-tree rstp [brief] [guard] brief (OPTIONAL) Enter the keyword brief to view a synopsis of the RSTP configuration information. guard (OPTIONAL) Enter the keyword guard to display the type of guard enabled on an RSTP interface and the current port state. • EXEC • EXEC Privilege Version Description 9.7(0.
Root ID Priority 8192, Address 0001.e805.e306 Root Bridge hello time 4, max age 20, forward delay 15 Bridge ID Priority 16384, Address 0001.e801.6aa8 Configured hello time 2, max age 20, forward delay 15 Interface Designated Name PortID Prio Cost Sts Cost Bridge ID PortID ---------- ------- --- ------- -------------------- -------Te 4/2/1 128.418 128 20000 FWD 20000 16384 0001.e801.6aa8 128.418 Te 4/1/1 128.419 128 20000 FWD 20000 16384 0001.e801.6aa8 128.419 Te 4/8/1 128.426 128 20000 FWD 20000 8192 0001.
spanning-tree rstp Configure an RSTP interface with one of these settings: port cost, edge port with optional bridge port data unit (BPDU) guard, port priority, loop guard, or root guard. Syntax Parameters spanning-tree rstp {cost port-cost | edge-port [bpduguard [shutdown-onviolation]] | priority priority | {loopguard | rootguard}} cost port-cost Enter the keyword cost then the port cost value. The range is from 1 to 200000.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.4.2.1 Added support for the optional guard keyword on the C-Series, S-Series, and ESeries TeraScale. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced the hardware shutdown-on-violation options. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 Added the optional bridge port data unit (BPDU) guard. 6.2.1.1 Introduced on the E-Series.
tc-flush-standard Enable the MAC address flushing after receiving every topology change notification. Syntax tc-flush-standard To disable, use the no tc-flush-standard command. Defaults Disabled Command Modes CONFIGURATION (conf-rstp) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
46 Security The commands in this chapter are available on Dell Networking OS. This chapter contains various types of security commands offered in the Dell Networking operating software. The commands are listed in the following sections: • AAA Accounting Commands • Authorization and Privilege Commands • Authentication and Password Commands • RADIUS Commands • TACACS+ Commands • Port Authentication (802.
commands {level | role role-name Enter the keyword command then a privilege level for accounting of commands executed at that privilege level or enter the keyword role then the role name for accounting of commands executed by a user with that user role. name | default Enter one of the following: • For name, enter a user-defined name of a list of accounting methods. • For default, the default accounting methods used.
Dell(conf)# aaa accounting command role secaadmin default start-stop tacacs + Related Commands enable password — changes the password for the enable command. login authentication — enables AAA login authentication on the terminal lines. password — creates a password. tacacs-server host — specifies a TACACS+ server host. aaa accounting suppress Prevent the generation of accounting records of users with the user name value of NULL.
accounting Apply an accounting method list to terminal lines. Syntax Parameters accounting {exec | commands {level | role role-name} method-list exec Enter the keyword exec to apply an EXEC level accounting method list. commands {level | role role-name} Enter the keywords commands level to apply an EXEC and CONFIGURATION level accounting method list by enter the keyword role and then the role name for accounting of commands executed by a user with that user role.
Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Introduced on the S-Series and Z-Series.
Version Description 6.3.1.0 Introduced on the E-Series. Usage Information This command steps through all active sessions and then displays the accounting records for the active account functions.
Related Commands Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.3.1.0 Introduced on the E-Series.
Version Description 9.2(1.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Added support for RADIUS. aaa authorization config-commands Set parameters that restrict (or permit) a user’s access to EXEC level commands.
To disable authorization checking for EXEC level commands, use the no aaa authorization exec command. Parameters name Define a name for the list of authorization methods. default Define the default list of authorization methods. local Use the authorization parameters on the system to perform authorization. tacacs+ Use the TACACS+ protocol to perform authorization. none Enter the keyword none to apply no authorization.
level level Enter the keyword level then a number for the access level. The range is from 0 to 15. Level 1 is EXEC mode and Level 15 allows access to all CLI modes and commands. reset Enter the keyword reset to return the security level to the default setting. command Enter the command’s keywords to assign the command to a certain access level. You can enter one or all of the keywords. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Obscure Password Commands To enable the obscure password, use the following commands.
Password obscuring masks the password and keys for display only but does not change the contents of the file. The string of asterisks is the same length as the encrypted string for that line of configuration. To verify that you have successfully obscured passwords and keys, use the show running-config command orshow startup-config command. If you are using role-based access control (RBAC), only the system administrator and security administrator roles can enable the service obscure-password command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series.
method ... method4 Enter one of the following methods: • enable: use the password the enable password command defines in CONFIGURATION mode. Not available if role-only is in use. • line: use the password the password command defines in LINE mode. Not available if role-only is in use. • local: use the password for the userid contained in the local password database. • none: no authentication. Not available if role-only is in use.
NOTE: If authentication fails using the primary method, Dell Networking OS employs the second method (or third method, if necessary) automatically. For example, if the TACACS+ server is reachable, but the server key is invalid, Dell Networking OS proceeds to the next authentication method. The TACACS+ is incorrect, but the user is still authenticated by the secondary method.
ip access-list extended — names (or selects) an extended access list based on the IP addresses or protocols. enable password Change the password for the enable command. Syntax enable password [level level] [encryption-type] password To delete a password, use the no enable password [encryption-type] password [level level] command. Parameters level level (OPTIONAL) Enter the keyword level then a number as the level of access. The range is from 1 to 15.
• Passwords can have a regular expression as the password. To create a password with a regular expression in it, use CNTL + v prior to entering regular expression. For example, to create the password abcd]e, you type “abcd CNTL v ]e”. When the password is created, you do not use the CNTL + v key combination and enter “abcd]e”. NOTE: The question mark (?) and the tilde (~) are not supported characters. Related Commands show running-config — views the current configuration.
enable secret Change the password for the enable command. Syntax enable secret [level level] [encryption-type] password To delete a password, use the no enable secret [encryption-type] password [level level] command. Parameters level level (OPTIONAL) Enter the keyword level then a number as the level of access. The range is from 1 to 15. encryption-type (OPTIONAL) Enter the number 5 or 0 as the encryption type. Enter a 5 then a text string as the hidden password.
abcd]e, you type “abcd CNTL v ]e”. When the password is created, you do not use the CNTL + v key combination and enter “abcd]e”. NOTE: The question mark (?) and the tilde (~) are not supported characters. Related Commands show running-config — views the current configuration. privilege level (CONFIGURATION mode) — controls access to the command modes within the switch. login authentication To configure authentication for console or remote access, apply an authentication method list.
Related Commands • If you configure the default authentication list using the default keyword, the list applies it to all the local and remote connections globally, unless you have specified some another authentication list for a specific connection. • If you configure an authentication lists other than default, you must apply those authentication lists to each connection.
Related Commands enable password — sets the password for the enable command. login authentication — configures an authentication method to log in to the switch. service password-encryption — encrypts all passwords configured in Dell Networking OS . radius-server key — configures a key for all RADIUS communications between the switch and the RADIUS host server. tacacs-server key — configures a key for communication between a TACACS+ server and client.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.0) Introduced lockout-period option on the Z9000, S6000, S4820T, S4810, and MXL. 9.2(1.0) Introduced on the Z9500. 9.0.2.
Version Description pre-6.1.1.0 Introduced on the E-Series. Usage Information CAUTION: Encrypting passwords with this command does not provide a high level of security. When the passwords are encrypted, you cannot return them to plain text unless you re-configure them. To remove an encrypted password, use the no password password command. To keep unauthorized people from viewing passwords in the switch configuration file, use the service password-encryption command.
show users Allows you to view information on all users logged in to the switch. Syntax Parameters show users [all] all (OPTIONAL) Enter the keyword all to view all terminal lines in the switch. Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
6 idle 7 idle Dell# Related Commands vty 4 admin 10.16.127.141 vty 5 ad 10.16.127.141 unassigned 1 unassigned 15 username — enables a user. timeout login response Specify how long the software waits for the login input (for example, the user name and password) before timing out. Syntax timeout login response seconds To return to the default values, use the no timeout login response command. Parameters seconds Enter a number of seconds the software waits before logging you out.
username Establish an authentication system based on user names. Syntax username name [access-class access-list-name] [nopassword | {password | secret} [encryption-type] password] [privilege level] [role role-name] If you do not want a specific user to enter a password, use the nopassword option. To delete authentication for a user, use the no username name command. Parameters name Enter a text string for the name of the user up to 63 characters.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Added support for the secret option and the MD5 password encryption. Extended the name from 25 to 63 characters. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information To view the defined user names, use the show running-config user command.
Version Description pre-6.2.1.0 Introduced on the E-Series. ip radius source-interface Specify an interface’s IP address as the source IP address for RADIUS connections. Syntax ip radius source-interface interface To delete a source interface, use the no ip radius source-interface command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information.
radius-server deadtime Configure a time interval during which non-responsive RADIUS servers to authentication requests are skipped. Syntax radius-server deadtime seconds To disable this function or return to the default value, use the no radius-server deadtime command. Parameters seconds Enter a number of seconds during which non-responsive RADIUS servers are skipped. The range is from 0 to 2147483647 seconds. The default is 0 seconds.
Version Description 9.4.(0.0) Introduced on the S-Series and Z-Series. Example Dell(conf)#radius-server group group1 Dell(conf-radius-group)#radius-server host 1.1.1.1 key secret Dell(conf-radius-group)#radius-server host 2.2.2.2 key secret Dell(conf-radius-group)#radius-server vrf vrf1 source-interface tengigabitethernet 1/3/1 Dell(conf-radius-group)#show config ! radius-server group group1 radius-server vrf vrf1 source-interface TenGigabitEthernet 1/3/1 radius-server host 1.1.1.
• 7 means that the password is encrypted and hidden. Configure this parameter last because leading spaces are ignored. Defaults Not configured. Command Modes Command History • RADIUS SERVER GROUP • CONFIGURATION This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
Example Dell(conf)#radius-server group group1 Dell(conf-radius-group)#radius-server host 1.1.1.1 key secret Dell(conf-radius-group)#no radius-server host 1.1.1.1 Related Commands login authentication — sets the database to be checked when a user logs in. radius-server key — sets an authentication key for RADIUS communications. radius-server retransmit — sets the number of times the RADIUS server attempts to send information.
Usage Information You can use this command to associate a group of RADIUS servers with a VRF and source interface. You can configure the source interface only with the VRF attribute and source interface is optional with the VRF attributes. If VRF is not configured on the RADIUS group, then the group is considered to be on the default VRF.
Usage Information Version Description 7.7.1.0 Authentication key length increased to 42 characters. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. The key configured on the switch must match the key configured on the RADIUS server daemon. If you configure the key parameter in the radius-server host command, the key configured with the radius-server key command is the default key for all RADIUS communications.
radius-server timeout To reply to a request, configure the amount of time the RADIUS client (the switch) waits for a RADIUS host server . Syntax radius-server timeout seconds To return to the default value, use the no radius-server timeout command. Parameters seconds Enter the number of seconds between an unsuccessful attempt and the Dell Networking OS times out. The range is from zero (0) to 1000 seconds. The default is 5 seconds.
Parameters group-name Enter the name of the TACACS server group. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.4.(0.0) Introduced on the S-Series and Z-Series.
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.2.1.0 Introduced on the E-Series. ip tacacs source-interface Specify an interface’s IP address as the source IP address for TACACS+ connections. Syntax ip tacacs source-interface interface To delete a source interface, use the no ip tacacs source-interface command.
tacacs-server group Creates a group of TACACS servers. Syntax tacacs-server group group-name To delete a group of TACACS servers, use the no tacacs-server group group-name command. Parameters group-name Enter the name of the TACACS server group. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
timeout seconds (OPTIONAL) Enter the keyword timeout then the number of seconds the switch waits for a reply from the TACACS+ server. The range is from 0 to 1000. The default is 10 seconds. key key (OPTIONAL) Enter the keyword key then a string up to 42 characters long as the authentication key. This authentication key must match the key specified in the tacacs-server key for the TACACS+ daemon. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Example Dell(conf)#tacacs-server group group1 Dell(conf-tacacs-group)#tacacs-server host 1.1.1.1 key secret Dell(conf-tacacs-group)#no tacacs-server host 1.1.1.1 Related Commands aaa authentication login — specifies the login authentication method. tacacs-server key — configures a TACACS+ key for the TACACS server. tacacs-server key Configure a key for communication between a TACACS+ server and a client.
tacacs-server vrf Create an association between a TACACS server group and a VRF and source interface. Syntax tacacs-server vrf vrf-name [source-interface interface] To delete the association between a TACACS server group and a VRF and source interface, use the no tacacs-server vrf vrf-name [source-interface interface] command. Parameters vrf vrf-name Enter the keyword vrf and then the name of the VRF to associate a TACACS server group with that VRF.
Dell(conf-tacacs-group)#tacacs-server vrf default Port Authentication (802.1X) Commands An authentication server must authenticate a client connected to an 802.1X switch port. Until the authentication, only Extensible Authentication Protocol over LAN (EAPOL) traffic is allowed through the port to which a client is connected. After authentication is successful, normal traffic passes through the port. Dell Networking OS supports RADIUS and Active Directory environments using 802.1X Port Authentication.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x authentication (Interface) — enables dot1x on an interface. dot1x authentication (Interface) Enable dot1x on an interface; dot1x must be enabled both globally and at the interface level. Syntax dot1x authentication To disable dot1x on an interface, use the no dot1x authentication command.
Defaults 3 attempts Command Modes CONFIGURATION (conf-if-interface-slot/port[/subport]) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.
Version Description 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. dot1x guest-vlan Configure a guest VLAN for limited access users or for devices that are not 802.1X capable. Syntax dot1x guest-vlan vlan-id To disable the guest VLAN, use the no dot1x guest-vlan vlan-id command. Parameters vlan-id Enter the VLAN Identifier. The range is from 1 to 4094. Defaults Not configured.
show dot1x interface — displays the 802.1X information on an interface. dot1x mac-auth-bypass Enable MAC authentication bypass. If 802.1X times out because the host did not respond to the Identity Request frame, Dell Networking OS attempts to authenticate the host based on its MAC address. Syntax [no] dot1x mac-auth-bypass Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific.
Related Commands Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.1.0 Introduced on the E-Series. interface range — configures a range of interfaces. dot1x port-control Enable port control on an interface.
Parameters seconds Enter the number of seconds. The range is from 1 to 65535. The default is 30. Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.
Related Commands Version Description 7.4.1.0 Introduced on the E-Series. interface range — configures a range of interfaces. dot1x reauth-max Configure the maximum number of times a port can re-authenticate before the port becomes unauthorized. Syntax dot1x reauth-max number To return to the default, use the no dot1x reauth-max command. Parameters number Enter the permitted number of re-authentications. The range is from 1 to 10. The default is 2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the C-Series and S-Series. 7.4.
dot1x tx-period Configure the intervals at which EAPOL PDUs are transmitted by the Authenticator PAE. Syntax dot1x tx-period seconds To return to the default, use the no dot1x tx-period command. Parameters seconds Enter the interval time, in seconds, that EAPOL PDUs are transmitted. The range is from 1 to 65535 (1 year). The default is 30. Defaults 30 seconds Command Modes INTERFACE Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.
ReAuth Max: Supplicant Timeout: Server Timeout: Re-Auth Interval: Max-EAP-Req: Host Mode: Auth PAE State: Backend State: Dell# 2 30 seconds 30 seconds 3600 seconds 2 SINGLE_HOST Initialize Initialize SSH Server and SCP Commands Dell Networking OS supports secure shell (SSH) protocol versions 1.5 and 2.0. SSH is a protocol for secure remote login over an insecure network. SSH sessions are encrypted and use authentication. crypto key generate Generate keys for the SSH server.
Usage Information Version Description pre-6.1.1.0 Introduced on the E-Series. The host keys are required for key-exchange by the SSH server. If the keys are not found when you enable the server (ip This command requires user interaction and generates a prompt prior to overwriting any existing host keys. NOTE: Only a user with superuser permissions should generate host-keys. Example Dell(conf)#crypto key generate rsa Enter key size <1024-2048>. Default<1024> : Host key already exists.
Parameters client Enter the keyword client to enable collecting debug information on the client. server Enter the keyword server to enable collecting debug information on the server. Defaults Disabled on both client and server. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information To configure the switch as an SCP server, use the ip ssh server command. Related Commands ip ssh server — enables the SSH and SCP server on the switch. ip ssh authentication-retries Configure the maximum number of attempts that should be used to authenticate a user.
Parameters 1-10 Enter the number of maximum numbers of incoming SSH connections allowed per minute. The range is from 1 to 10 per minute. The default is 10 per minute. Defaults 10 per minute Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Usage Information Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. If you enable this command, clients can log in without a password prompt. This command provides two levels of authentication: • rhost-authentication is done with the file specified in the ip ssh rhostfile command. • checking client host-keys is done with the file specified in the ip ssh pub-key-file command.
ip ssh password-authentication Enable password authentication for the SSH server. Syntax ip ssh password-authentication enable To disable password-authentication, use the no ip ssh password-authentication enable command. Parameters enable Enter the keyword enable to enable password-authentication for the SSH server. Defaults Enabled Command Modes CONFIGURATION Command History This guide is platform-specific.
Defaults The default time is 60 minutes. The default volume is 1024 megabytes. Command Modes CONFIGURATION mode Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.5(0.
+DWEc3cgYAcU5Lai1MU2ODrzhCwyDNp05tKBU3t ReG1o8AxLi6+S4hyEMqHzkzBFNVqHzpQc +Rs4p2urzV0F4pRKnaXdHf3Lk4D460HZRhhVrxqeNxPDpEn WIMPJi0ds= ashwani@poclab4 NOTE: For rhostfile and pub-key-file, the administrator must FTP the file to the chassis. Example Dell#conf Dell(conf)# ip ssh pub-key-file flash://knownhosts Dell(conf)# Related Commands show ip ssh client-pub-keys — displays the client-public keys used for the host-based authentication.
ip ssh rsa-authentication (Config) Enable RSA authentication for the SSHv2 server. Syntax ip ssh rsa-authentication enable To disable RSA authentication, use the no ip ssh rsa-authentication enable command. Parameters enable Enter the keyword enable to enable RSA authentication for the SSHv2 server. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Parameters enable Enter the key word enable to start the SSH server. ciphers cipher-list Enter the keyword ciphers and then a space-delimited list of ciphers that the SSH server supports. The following ciphers are available. • 3des-cbc • aes128-cbc • aes192-cbc • aes256-cbc • aes128-ctr • aes192-ctr • aes256-ctr The default cipher list is used.
kex key-exchangealgorithm Enter the keyword kex and then a space-delimited list of key exchange algorithms supported by the SSH server. The following key exchange algorithms are available: • diffie-hellman-group-exchange-sha1 • diffie-hellman-group1-sha1 • diffie-hellman-group14-sha1 When FIPS is enabled, the default key-exchange-algorithm is diffie-hellmangroup14-sha1.
Usage Information Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. This command enables the SSH server and begins listening on a port. If a port is not specified, listening is on SSH default port 22. NOTE: Starting with Dell Networking OS Release 9.2(0.0), SSH server is enabled by default.
Usage Information You can enable the SSH server on either a management VRF or a user defined VRF but not both. If no VRF is specified, then the SSH server is enabled on the default VRF. If the SSH server is enabled on a VRF with name vrf1, then use the following command to restart the SSH server on a VRF with name vrf2: ip ssh server vrf vrf2. If the SSH server is enabled on a VRF with name vrf1, then use the following command to restart the SSH server on the default VRF: ip ssh server vrf.
Usage Information The source-interface interface attribute is applicable for both the SSH client as well as the COPY (SCP) commands. Using these attributes the client session tags an error to the user during run time, in case there is a mismatch between this command and the ip ssh vrf command. Example Dell(conf)#ip ssh source-interface tengigabitethernet 1/30/1 Dell(conf)#do ssh 10.10.10.2 -l admin Dell(conf)#no ip ssh source-interface ip ssh vrf Specify a VRF for an outgoing SSH connections.
rsa Enter the keyword rsa to display the host SSHv2 RSA public key. rsa1 Enter the keyword rsa1 to display the host SSHv1 RSA public key. NOTE: If you enable FIPS mode, this parameter is not available. Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.
Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Example Dell#show ip ssh SSH server : enabled. SSH server version : v1 and v2. SSH server vrf : default.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information This command displays the contents of the flash://ADMIN_DIRssh/knownhosts file. Example Dell# show ip ssh client-pub-keys 4.8.1.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. pre-6.1.1.0 Introduced on the E-Series. Usage Information This command displays the contents of the flash:/ADMIN_DIR/ssh/authorized-keys.username file.
-l username (OPTIONAL) Enter the keyword -l then the user name used in this SSH session. The default is the user name of the user associated with the terminal. -m HMAC algorithm Enter one of the following HMAC algorithms to use. (For v2 clients only): "no fips mode enable"(disable) will support v1 & v2 client. • hmac-md5: Force ssh to use hmac-md5 HMAC algorithm. • hmac-md5-96: Force ssh to use hmac-md5-96 HMAC algorithm. • hmac-sha1: Force ssh to use hmac-sha1 HMAC algorithm.
Secure DHCP Commands DHCP as defined by RFC 2131 provides no authentication or security mechanisms. Secure DHCP is a suite of features that protects networks that use dynamic address allocation from spoofing and attacks. clear ip dhcp snooping Clear the DHCP binding table. Syntax clear ip dhcp snooping binding Defaults none Command Modes EXEC Privilege Command History This guide is platform-specific.
7.8.1.0 Introduced on the C-Series and S-Series. ip dhcp snooping Enable DHCP Snooping globally. Syntax [no] ip dhcp snooping Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.
• Defaults For a Loopback interface, enter the keyword loopback then a number from 0 to 16383. slot/port Enter the slot and port number of the interface. lease time Enter the keyword lease then the amount of time the IP address is leased. The range is from 1 to 4294967295. none Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. ip dhcp snooping trust Configure an interface as trusted. Syntax [no] ip dhcp snooping trust Defaults Untrusted Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 7.8.1.0 Introduced on the C-Series and S-Series. ip dhcp snooping vlan Enable DHCP Snooping on one or more VLANs. Syntax [no] ip dhcp snooping vlan name Parameters name Enter the name of a VLAN on which to enable DHCP Snooping. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Related Commands Version Description 9.7(0.0) Introduced on the S6000–ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.8.1.0 Introduced on the C-Series and S-Series. clear ip dhcp snooping — clears the contents of the DHCP binding table. Role-Based Access Control Commands With Role-Based Access Control (RBAC), access and authorization is controlled based on a user’s role.
Usage Information Version Description 9.5(0.0) Introduced on the Z9000, S6000, S4820T, S4810, and MXL. By default, access to commands are determined by the user’s role (if defined) or by the user’s privilege level. If the aaa authorization role-only command is enabled, then only the user’s role is used. Before you enable role-based only AAA authorization: Related Commands 1. Locally define a system administrator user role.
command Defaults none Command Modes CONFIGURATION Command History Related Commands Enter the command’s keywords to assign the command to a certain access level. You can enter one or more keywords. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9000, S6000, S4820T, S4810, and MXL. userrole show role Display information on permissions assigned to a command, including user role and/or permission level.
show userroles Display information on all defined user roles. Syntax show userroles Example Dell#show userroles Role Inheritance netoperator netadmin secadmin sysadmin netoperator testadmin Command Modes Command History Related Commands netadmin Modes Exec Exec Config Interface Line Router IP Route-map Protocol MAC Exec Config Exec Config Interface Line Router IP Route-map Protocol MAC Exec Config Interface Line Router IP Route-map Protocol MAC EXEC Privilege Version Description 9.7(0.
NOTE: You can change user role permissions on system pre-defined user roles or user-defined user roles. Important Points to Remember Consider the following when creating a user role: • Only the system administrator and user-defined roles inherited from the system administrator can create roles and usernames. Only the system administrator, security administrator, and roles inherited from these can use the role command to modify command permissions.
47 Service Provider Bridging Service provider bridging is composed of virtual local area network (VLAN) Stacking, Layer 2 Protocol Tunneling, and Provider Backbone Bridging as described in the Dell Networking OS Configuration Guide Service Provider Bridging chapter. This chapter includes command line information (CLI) for the Dell Networking operating software Layer 2 Protocol Tunneling (L2PT). L2PT enables protocols to tunnel through an 802.1q tunnel. Dell Networking OS supports L2PT on Dell Networking OS.
• For a Port Channel interface, enter the keywords port-channel then a number. The range is from 1 to 128. in | out | both Enter the keyword in, out, or both to debug incoming interfaces, outgoing interfaces, or both incoming and outgoing interfaces. vlan vlan-id Enter the keyword vlan then the VLAN ID. The range is from 1 to 4094. count value Enter the keyword count then the number of debug outputs. The range is from 1 to 100. Defaults Debug disabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guid. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.5.1.1 Added support for 802.1X, E-LMI, GMRP, GVRP, LLDP, LACP, MMRP, MVRP, and OAM 802.
Version Description 7.4.1.0 Introduced Usage Information When you enable VLAN-Stacking, no protocol packets are tunneled. Related Command show protocol-tunnel — displays tunneling information for all VLANs. protocol-tunnel enable Enable protocol tunneling globally on the system. Syntax protocol-tunnel enable To disable protocol tunneling, use the no protocol-tunnel enable command. Defaults Disabled. Command Modes CONFIGURATION Command History This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.
Example Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the C-Series, E-Series and E-Series ExaScale. 7.4.1.
48 sFlow The Dell Networking operating software (OS) supports sFlow commands on Dell Networking OS. Dell Networking operating software sFlow monitoring system includes an sFlow Agent and an sFlow Collector. • The sFlow Agent combines the flow samples and interface counters into sFlow datagrams and forwards them to the sFlow Collector. • The sFlow Collector analyses the sFlow Datagrams received from the different devices and produces a network-wide view of traffic flows.
To delete a configured collector, use the no sflow collector {ip-address | ipv6-address} agent-addr {ipv4-address | ipv6-address} [number [max-datagram-size number]] | [max-datagram-size number] [vrf management] command. Parameters sflow collector ipaddress | ipv6address Enter the IP address of the collector in dotted decimal format for IPv4 or x:x:x:x::x format for IPv6.
Usage Information Version Description 6.2.1.1 Introduced on the E-Series. You can configure up to two sFlow collectors (IPv4 or IPv6). If two collectors are configured, traffic samples are sent to both. The sFlow agent address is carried in a field in SFlow packets and is used by the collector to identify the sFlow agent. In sFlow, the agent address is a single invariant IPv4 or IPv6 address used to identify the agent to the collector.
Version Description 7.6.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information sFlow is disabled by default. In addition to this command, sFlow needs to be enable on individual interfaces where sFlow sampling is desired. Related Commands sflow enable (Interface) — enables sFlow on interfaces. sflow ingress-enable Enable sFlow ingress on interfaces. Syntax sflow ingress-enable To disable sFlow, use the no sflow ingress enable command. Defaults Disabled.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Introduced on the S Series and Z Series switches. Dell(conf)#sflow max-header-size extended sflow polling-interval (Global) Set the sFlow polling interval at a global level. Syntax sflow polling-interval interval value To return to the default, use the no sflow polling-interval interval command. Parameters interval value Enter the interval value in seconds. The range is from 15 to 86400 seconds. The default is 20 seconds.
sflow polling-interval (Interface) Set the sFlow polling interval at an interface (overrides the global-level setting.) Syntax sflow polling-interval interval value To return to the default, use the no sflow polling-interval interval command. Parameters interval value Enter the interval value in seconds. The range is from 15 to 86400 seconds. The default is the global counter polling interval. Defaults The same value as the current global default counter polling interval.
Defaults 32768 packets Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.0 Introduced on the E-Series ExaScale. 7.7.1.0 Introduced on the S-Series. 7.6.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on S-Series Stacking. 8.1.1.
49 Simple Network Management Protocol (SNMP) and Syslog This chapter contains commands to configure and monitor the simple network management protocol (SNMP) v1/v2/v3 and Syslog. Both features are supported on Dell Networking OS. The chapter contains the following sections: • SNMP Commands • Syslog Commands SNMP Commands The following SNMP commands are available in the Dell Networking OS.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. Example Dell#show snmp engineID Local SNMP engineID: 0000178B02000001E80214A8 Remote Engine ID IP-addr Port 80001F88043132333435 172.31.1.3 5009 80001F88043938373635 172.31.1.
Example Related Commands Dell#show snmp group groupname: v1v2creadg readview : v1v2cdefault notifyview: v1v2cdefault row status: active Dell# security model: v1 writeview: no write view specified context: no context specified snmp-server group — configures an SNMP server group. show snmp user Display the information configured on each SNMP user name. Syntax Command Modes Command History show snmp user • EXEC • EXEC Privilege This guide is platform-specific.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
ipv6 access-listname (Optional) Enter the keyword ipv6 then an IPv6 ACL name (a string up to 16 characters long). security-name name (Optional) Enter the keywords security-name then the security name as defined by the community MIB. access-list-name (Optional) Enter a standard IPv4 access list name (a string up to 16 characters long). Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
Example Dell#config Dell(conf)# snmp-server community public ro Dell(conf)# snmp-server community guest ro security-name guestuser Dell(conf)# Example Dell(conf)# ip access-list standard snmp-ro-acl Dell(config-std-nacl)#seq 5 permit host 10.10.10.224 Dell(config-std-nacl)#seq 10 deny any count ! Dell(conf)#snmp-server community guest ro snmp-ro-acl Dell(conf)# Related Commands ip access-list standard — names (or selects) a standard access list to filter based on IP address.
snmp-server enable traps Enable SNMP traps. Syntax snmp-server enable traps [notification-type] [notification-option] To disable traps, use the no snmp-server enable traps [notification-type] [notification-option] command. Parameters notification-type notification-option Enter the type of notification from the following list: • bgp — Notification of changes in the BGP process. • config — Notification of changes to the startup or running configuration. • ecfm — Notification of changes to ECFM.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Added support for copy-config and ecmp traps. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.4.1.0 Added support for VRRP traps. 7.6.1.0 Added support for STP and xSTP traps. Introduced on the S-Series. 7.5.1.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
• 1 | 2c | 3 1v2cwriteg — maps to a community/security-name rw permissions. (OPTIONAL) Enter the security model version number (1, 2c, or 3): • 1 is the least secure version. • 3 is the most secure of the security modes. • 2c allows transmission of informs and counter 64, which allows for integers twice the width of what is normally allowed. The default is 1. auth (OPTIONAL) Enter the keyword auth to specify authentication of a packet without encryption.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information The following Example specifies the group named harig as a version 3 user requiring both authentication and encryption and read access limited to the read named rview. NOTE: The number of configurable groups is limited to 16 groups.
auth (OPTIONAL) Enter the keyword auth to specify authentication of a packet without encryption. noauth (OPTIONAL) Enter the keyword noauth to specify no authentication of a packet. priv (OPTIONAL) Enter the keyword priv to specify both authentication and then scrambling of the packet. community-string Enter a text string (up to 20 characters long) as the name of the SNMP community. NOTE: For version 1 and version 2c security models, this string represents the name of the SNMP community.
Version Description 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 9.1(0.0) Added support for config and ecmp traps. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.4.1.0 Added support for VRRP traps. 7.6.1.0 Added support for STP and xSTP notification types. Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series.
snmp-server community — configures a new community SNMPv1 or SNMPv2c. snmp-server location Configure the location of the SNMP server. Syntax snmp-server location text To delete the SNMP location, use the no snmp-server location command. Parameters text Enter an alpha-numeric text string, up to 55 characters long. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command snmp-server trap-source Configure a specific interface as the source for SNMP traffic.
Version Description 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information To enable this snmp-server trap-source command, configure an IP address on the interface and enable the interface configured as an SNMP trap source. Related Commands snmp-server community — sets the community string. snmp-server user Configure a new user to an SNMP group.
auth (OPTIONAL) Enter the keyword auth to specify authentication of a packet without encryption. md5 | sha (OPTIONAL) Enter the keyword md5 or sha to designate the authentication level. • md5 — Message Digest Algorithm • sha — Secure Hash Algorithm auth-password (OPTIONAL) Enter a text string (up to 20 characters long) password that enables the agent to receive packets from the host. Minimum: eight characters long.
Usage Information NOTE: For IPv6 ACLs, only IPv6 and UDP types are valid for SNMP. TCP and ICMP rules are not valid for SNMP. In IPv6 ACLs port rules are not valid for SNMP. No default values exist for authentication or privacy algorithms and no default password exists. If you forget a password, you cannot recover it; the user must be reconfigured. You can specify either a plain-text password or an encrypted cypher-text password.
aes128 (OPTIONAL) Enter the keyword aes128 to initiate the AES128-CFB encryption algorithm for transmission of SNMP packets. priv-password (OPTIONAL) Enter a text string (up to 20 characters long) password that enables the host to encrypt the contents of the message it sends to the agent and to decrypt the contents of the message it receives from the agent. Minimum: eight characters long.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Usage Information Use this command to bind an SNMP agent to a VRF. The SNMP agent processes the requests from the interfaces that belong to the specified VRF. If no VRF is specified, then the default VRF is used. Related Commands show snmp user — displays the information configured on each SNMP user name. snmp trap link-status Enable the interface to send SNMP link traps, which indicate whether the interface is up or down.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.
Defaults size = 40960; level = 7 or debugging Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 7.6.1.
default logging monitor Return to the default settings for messages logged to the terminal. Syntax default logging monitor Defaults level = 7 or debugging Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Related Commands logging trap — limit messages logged to the Syslog servers based on severity. logging Configure an IP address or host name of a Syslog server where logging messages are sent. Multiple logging servers of both IPv4 and/or IPv6 can be configured.
Version Description 8.4.1.0 Added support for IPv6. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information Multiple logging servers of both IPv4 and/or IPv6 can be configured. Related Commands logging on — enables the logging asynchronously to logging buffer, console, Syslog server, and terminal lines. logging trap — enables logging to the Syslog server based on severity.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information When you decrease the buffer size, all messages stored in the buffer are lost. Increasing the buffer size does not affect messages stored in the buffer. Related Commands clear logging — clears the logging buffer. default logging buffered — returns the logging buffered parameters to the default setting.
Version Description E-Series legacy command Related Commands clear logging — clears the logging buffer. default logging console — returns the logging console parameters to the default setting. show logging — displays the logging setting and system messages in the internal buffer. logging extended Logs security and audit events to a system log server. Syntax logging extended Defaults none Command Modes CONFIGURATION Command History This guide is platform-specific.
To return to the default values, use the no logging facility command.
Version Description 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Related Commands logging — enables logging to a Syslog server. logging on — enables logging. logging history Specify which messages are logged to the history table of the switch and the SNMP network management station (if configured). Syntax logging history level To return to the default values, use the no logging history command.
logging history size Specify the number of messages stored in the Dell Networking logging history table. Syntax logging history size size To return to the default values, use the no logging history size command. Parameters size Indicate a value as the number of messages to be stored. The range is from 0 to 500. The default is 1 message. Defaults 1 message Command Modes CONFIGURATION Command History This guide is platform-specific.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.
Version Description 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information When you use the no logging on command, messages are logged only to the console. Related Commands logging — enables logging to the Syslog server. logging buffered — sets the logging buffered parameters. logging console — sets the logging console parameters. logging monitor — sets the logging parameters for the terminal connections.
Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information When you enable logging synchronous, unsolicited messages appear between software prompts and outputs. Only the messages with a severity at or below the set level are sent to the console.
Version Description 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series, S55. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Usage Information To block a type of message parameter, set the logging trap level to a lower number. For example, to block severity messages at level 6, set the level to 5. Related Commands logging — enables the logging to another device. logging on — enables logging. logging version Displays syslog messages in a RFC 3164 or RFC 5424 format.
show logging auditlog Displays an audit log. Syntax show logging auditlog Defaults none Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL.
Version Description 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series.
Parameters defaults Command Modes Command History stack-unit unit# Enter the keywords stack-unit followed by the stack member ID of the switch for which you want to display the driver log. The range is from 0 to 7. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. E-Series legacy command Related Commands 1296 logging monitor — sets the logging parameters on the monitor/terminal.
50 SNMP Traps This chapter lists the traps sent by the Dell Networking operating software. Each trap is listed by the fields Message ID, Trap Type, and Trap Option. Message ID Trap Type Trap Option COLD_START SNMP COLDSTART WARM_START SNMP WARMSTART COPY_CONFIG_COMPLETE SNMP NONE SNMP LINKDOWN SNMP LINKUP SNMP AUTH EGP_NEIGHBOR_LOSS SNMP NONE OSTATE_DOWN SNMP LINKDOWN SNMP LINKUP SNMP NONE SNMP NONE SNMP NONE SNMP NONE %SNMP-5-SNMP_COLD_START: SNMP COLD_START trap sent.
Message ID Trap Type Trap Option SNMP NONE SNMP NONE SNMP NONE NONE NONE ENVMON NONE ENVMON NONE ENVMON NONE CHM_CARD_PROBLEM ENVMON NONE CHM_ALARM_CUTOFF ENVMON NONE CHM_SFM_UP ENVMON NONE CHM_SFM_DOWN ENVMON NONE CHM_RPM_UP ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE %RPM0-P:CP %SNMP-4-RMON_HC_FALLING_THRESHOLD: RMON highcapacity falling threshold alarm from SNMP OID BER_ERR %IFMGR-5-BER_ERR: High Ber detected on interface : %s BER_ERR_CLR %IFMGR-5-BER_ERR_C
Message ID Trap Type Trap Option CHM_SFM_REMOVE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON SUPPLY ENVMON TEMP ENVMON TEMP ENVMON TEMP ENVMON TEMP ENVMON FAN %TSM-5-SFM_REMOVE: Removed SFM 1 CHM_MAJ_SFM_DOWN %CHMGR-0-MAJOR_SFM: Major alarm: Switch fabric down CHM_MAJ_SFM_DOWN_CLR %CHMGR-5-MAJOR_SFM_CLR: Major alarm cleared: Switch fabric up CHM_MIN_SFM_DOWN %CHMGR-2-MINOR_SFM: MIn
Message ID Trap Type Trap Option ENVMON FAN ENVMON FAN ENVMON FAN ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE ENVMON NONE For E1200: %CHMGR-2-FAN_TRAY_BAD: Major alarm: fan tray %d is missing or down %CHMGR-2-ALL_FAN_BAD: Major alarm: all fans in fan tray %d are down.
Message ID Trap Type Trap Option ENVMON NONE ENVMON NONE ENVMON NONE PROTO NONE PROTO NONE PROTO NONE PROTO NONE PROTO NONE %MACMGR-5-DETECT_STN_MOVE: Station Move threshold exceeded for Mac %s in vlan %d PORT_TEMP_MAJOR %CHMGR-1-PORT_TEMP_MAJOR: Major Alarm Interface %s shut due to high temperature PORT_TEMP_MINOR %CHMGR-1-PORT_TEMP_MINOR: Minor Alarm Interface %s temperature exceeds threshold PORT_TEMP_MAJOR_CLR %CHMGR-1-PORT_TEMP_MAJOR_CLR: Major Alarm cleared for Interface %s port tem
51 Storm Control The Dell Networking operating software storm control feature allows you to limit or suppress traffic during a traffic storm (Broadcast/Unknown Unicast Rate Limiting or Multicast on the C-Series and S-Series). Storm control is supported on Dell Networking OS. Important Points to Remember • Interface commands can only be applied on physical interfaces (virtual local area networks [VLANs] and link aggregation group [LAG] interfaces are not supported).
• Defaults Command Modes Command History For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. none • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.
The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.0 Added support for 4-port 40G line cards on ExaScale. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.
Usage Information Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 7.4.1.0 E-Series Only: Added the percentage decimal value option. 6.5.1.0 Introduced on the E-Series. Broadcast storm control is valid on Layer 2/Layer 3 interfaces only. Layer 2 broadcast traffic is treated as unknown-unicast traffic.
storm-control multicast (Configuration) Configure the packets per second (pps) of multicast traffic allowed into the C-Series and S-Series networks only. Syntax storm-control multicast packets_per_second in To disable storm-control for multicast traffic into the network, use the no storm-control multicast packets_per_second in command. Parameters packets_per_secon d in Enter the packets per second of multicast traffic allowed into the network. The range is from 0 to 33554368.
Command Modes INTERFACE (conf-if-interface-slot/port) Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810.
Usage Information Version Description 6.5.1.0 Introduced on the E-Series. Unknown Unicast Storm-Control is valid for Layer 2 and Layer 2/Layer 3 interfaces. storm-control unknown-unicast (Interface) Configure percentage of unknown-unicast traffic allowed on an interface (ingress only).
Storm Control Version Description 7.5.1.0 Introduced on the C-Series. 7.4.1.0 E-Series Only: Added the percentage decimal value option. 6.5.1.0 Introduced on the E-Series.
52 Spanning Tree Protocol (STP) The commands in this chapter configure and monitor the IEEE 802.1d spanning tree protocol (STP) and are supported on the Dell Networking switch/routing platform. bridge-priority Set the bridge priority of the switch in an IEEE 802.1D spanning tree. Syntax bridge-priority {priority-value | primary | secondary} To return to the default value, use the no bridge-priority command. Parameters priority-value Enter a number as the bridge priority value.
bpdu-destination-mac-address Use the Provider Bridge Group address in Spanning Tree or GVRP PDUs. Syntax bpdu-destination-mac-address [stp | gvrp] provider-bridge-group Parameters xstp Force STP, RSTP, and MSTP to use the Provider Bridge Group address as the destination MAC address in its BPDUs. gvrp Forces GVRP to use the Provider Bridge GVRP Address as the destination MAC address in its PDUs. Defaults The destination MAC address for BPDUs is the Bridge Group Address.
Command Modes EXEC Privilege Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.
Related Commands Version Description 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced protocol spanning-tree — enters SPANNING TREE mode on the switch. disable Disable the spanning tree protocol globally on the switch. Syntax disable To enable Spanning Tree Protocol, use the no disable command. Defaults Enabled (that is, the spanning tree protocol is disabled.) Command Modes SPANNING TREE Command History This guide is platform-specific.
Defaults 15 seconds Command Modes SPANNING TREE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.
Related Commands Version Description 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. forward-delay — changes the wait time before STP transitions to the Forwarding state. max-age — changes the wait time before STP refreshes protocol configuration information.
protocol spanning-tree To enable and configure the spanning tree group, enter SPANNING TREE mode. Syntax protocol spanning-tree stp-id To disable the Spanning Tree group, use the no protocol spanning-tree stp-id command. Parameters stp-id Enter zero (0). Dell Networking OS supports one spanning tree group, group 0. Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific.
Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.7.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.5.1.
Example Field Description “Designated port...” Displays the designated port ID. Dell#show spann 0 Executing IEEE compatible Spanning Tree Protocol Bridge Identifier has priority 32768, Address 0001.e800.0a56 Configured hello time 2, max age 20, forward delay 15 We are the root of the spanning tree Current root has priority 32768 address 0001.e800.
Usage Information Example (Guard) The following describes the show spanning-tree 0 guard command shown in the example. Field Description Interface Name STP interface. Instance STP 0 instance. Sts Port state: root-inconsistent (INCON Root), forwarding (FWD), listening (LIS), blocking (BLK), or shut down (EDS Shut). Guard Type Type of STP guard configured (Root, Loop, or BPDU guard).
Enter the optional keyword shutdown-on-violation to hardware disable an interface when a BPDU is received and the port is disabled. priority priority Enter keyword priority then a number as the priority. The range is from zero (0) to 15. The default is 8. Defaults cost = depends on the interface type; priority = 8 Command Modes INTERFACE Command History This guide is platform-specific.
• If a BPDU is received from a remote device, BPDU guard places the port in an Err-Disabled Blocking state and no traffic is forwarded on the port. • If no BPDU is received from a remote device, loop guard places the port in a Loop-Inconsistent Blocking state and no traffic is forwarded on the port. To display the type of STP guard (Portfast BPDU, root, or loop guard) enabled on a port, enter the show spanning-tree 0 command.
53 System Time and Date The commands in this chapter configure time values on the system, either using the Dell Networking operating software, or the hardware, or using the network time protocol (NTP). With NTP, the switch can act only as a client to an NTP clock host. For more information, refer to the “Network Time Protocol” section of the Management chapter in the Dell Networking OS Configuration Guide.
Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.
start-month Enter the name of one of the 12 months in English. start-time Enter the time in hours:minutes. For the hour variable, use the 24-hour format; example, 17:15 is 5:15 pm. end-week Enter the one of the following as the week that daylight saving ends: • week-number: enter a number from 1 to 4 as the number of the week to end daylight saving time. • first: enter the keyword first to end daylight saving time in the first week of the month.
clock timezone Configure a timezone for the switch. Syntax clock timezone timezone-name offset To delete a timezone configuration, use the no clock timezone command. Parameters timezone-name Enter the name of the timezone. You cannot use spaces. offset Enter one of the following: • a number from 1 to 23 as the number of hours in addition to universal time coordinated (UTC) for the timezone. • a minus sign (-) then a number from 1 to 23 as the number of hours. Defaults Not configured.
Parameters adjust Enter the keyword adjust to display information on NTP clock adjustments. all Enter the keyword all to display information on all NTP transactions. authentication Enter the keyword authentication to display information on NTP authentication transactions. events Enter the keyword events to display information on NTP events. loopfilter Enter the keyword loopfilter to display information on NTP local clock frequency.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. You also must configure an authentication key for NTP traffic using the ntp authentication-key command.
ntp disable Prevent an interface from receiving NTP packets. Syntax ntp disable To re-enable NTP on an interface, use the no ntp disable command. Defaults Disabled (that is, if you configure an NTP host, all interfaces receive NTP packets) Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added support for IPv6 multicast addresses. 8.3.7.0 Introduced on the S4810.
Parameters vrf vrf-name (Optional) Enter the keyword vrf and then the name of the VRF to configure a NTP time-serving host corresponding to that VRF. ipv4-address | ipv6address Enter an IPv4 address (A.B.C.D) or IPv6 address (X:X:X:X::X) of NTP server. hostname Enter the hostname of the server. key keyid (OPTIONAL) Enter the keyword key and a number as the NTP peer key. The range is from 1 to 4294967295.
ntp source Specify an interface’s IP address to be included in the NTP packets. Syntax ntp source interface To delete the configuration, use the no ntp source command. Parameters interface Enter the following keywords and slot/port or number information: • For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.
Defaults Not configured. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 7.6.1.0 Introduced on the S-Series. 7.5.1.
The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.2.1.0 Added options [0 | 7] for entering the authentication key. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.1.1.0 Introduced on the E-Series. Example Dell#show clock 11:05:56.949 UTC Thu Oct 25 2001 Dell# Example (Detail) Dell#show clock detail 12:18:10.
Usage Information Version Description 6.1.1.0 Introduced on the E-Series. The following describes the show ntp associations command shown in the Example below. Field Description (none) One or more of the following symbols could be displayed: • * means synchronized to this peer. • # means almost synchronized to this peer. • + means the peer was selected for possible synchronization. • - means the peer is a candidate for selection. • ~ means the peer is statically configured.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.6(0.0) Added support for VRF. 9.4.(0.0) Added support for VRF. 9.0.2.0 Introduced on the S6000. 8.3.11.1 Introduced on the Z9000. 8.4.1.0 Added IPv6 support. 7.6.1.
Field Description “Clock is...” States whether or not the switch clock is synchronized, which NTP stratum the system is assigned and the IP address of the NTP peer. “frequency is...” Displays the frequency (in ppm), stability (in ppm) and precision (in Hertz) of the clock in this system. “reference time is...” Displays the reference time stamp. “clock offset is...” Displays the system offset to the synchronized peer and the time delay on the path to the NTP root clock. “root dispersion is...
54 Tunneling Tunneling is supported on Dell Networking OS. tunnel-mode Enable a tunnel interface. . Syntax tunnel mode {ipip | ipv6 | ipv6ip}[decapsulate-any] To disable an active tunnel interface, use the no tunnel mode command. Parameters ipip Enable tunnel in RFC 2003 mode and encapsulate IPv4 and/or IPv6 datagrams inside an IPv4 tunnel. ipv6 Enable tunnel in RFC 2473 mode and encapsulate IPv4 and/or IPv6 datagrams inside an IPv6 tunnel.
tunnel source Set a source address for the tunnel. Syntax tunnel source {ip-address | ipv6–address | interface-type-number | anylocal} To delete the current tunnel source address, use the no tunnel source command. Parameters ip-address Enter the source IPv4 address in A.B.C.D format. ipv6–address Enter the source IPv6 address in X:X:X:X::X format. interface-typenumber • For a port channel interface, enter the keywords port-channel then a number from 1 to 128.
Parameters ip-address ipv6 address Enter the IPv4 or IPv6 address of the peer to which the keepalive probes will be sent. interval seconds Enter the keyword interval then the interval time, in seconds, after which the restart process to keepalive probe packets. The range is from 5 to 255. The default is 5. count (OPTIONAL) Enter the keyword count to count packets processed by the filter. The range is from 3 to 10. The default is 3.
ipv6–address Enter the source IPv6 address in X:X:X:X::X format. mask (OPTIONAL) Enter a network mask in /prefix format (/x) or A.B.C.D to match a range of remote addresses. The default mask is /32 for IPv4 addresses and /128 for IPv6 addresses, which match only the specified address. Defaults If you do not configure tunnel allow remote , all traffic which is destined to tunnel source address is decapsulated. Command Modes INTERFACE TUNNEL Command History Usage Information Version Description 9.
Usage Information This command configures the method used to set the high 6 bits (the differentiated services codepoint) of the IPv4 TOS or the IPv6 traffic class in the outer IP header. A value of 0 copies original packet DSCP (IPv4)/Traffic Class (IPv6) to the tunnel header DSCP (IPv4)/ Traffic Class (IPv6) depending on the mode of tunnel. tunnel flow-label Configure the method to set the IPv6 flow label value in the outer tunnel header.
Usage Information A value of 0 copies the inner packet hop limit (ipv6) or time-to-live (ipv4) in the encapsulated packet to the tunnel header hop limit (ipv6) or time-to-live (ipv4) value. tunnel destination Set a destination endpoint for the tunnel. Syntax tunnel destination {ip-address | ipv6–address} To delete a tunnel destination address, use the no tunnel destination {ip-address | ipv6– address} command. Parameters ip-address Enter the destination IPv4 address for the tunnel.
Command Modes Command History Usage Information INTERFACE TUNNEL Version Description 9.7(0.0) Introduced on the S6000-ON. 9.3(0.1) Introduced on the S6000 and Z9000. 9.4(0.1) Introduced on the S4810, S4820T, S6000 and Z9000. The ip unnumbered command fails in two conditions: • If the logical ip address is configured. • If Tunnel mode is ipv6ip (where ip address over tunnel interface is not possible).
NOTE: The ipv6 unnumbered command can specify an interface name that does not exist or does not have a configured IPv6 address. The tunnel interface is not changed to operationally up until the logical ip address is identified from one of the address family.
55 VLAN Stacking With the virtual local area network (VLAN)-stacking feature (also called stackable VLANs and QinQ), you can “stack” VLANs into one tunnel and switch them through the network transparently. The Dell Networking operating software supports this feature on Dell Networking OS. For more information about basic VLAN commands, refer to the Virtual LAN (VLAN) Commands section in the Layer 2 chapter.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.3.1.0 Introduced on the C-Series and S-Series. dei honor Honor the incoming DEI value by mapping it to an Dell Networking OS drop precedence. Enter the command once for 0 and once for 1. Syntax Parameters dei honor {0 | 1} {green | red | yellow} 0|1 Enter the bit value you want to map to a color.
dei mark Set the DEI value on egress according to the color currently assigned to the packet. S6000–ON Syntax dei mark {green | yellow} {0 | 1} Parameters 0|1 Enter the bit value you want to map to a color. green | red | yellow Choose a color: • Green: High priority packets that are the least preferred to be dropped. • Yellow: Lower priority packets that are treated as best-effort. Defaults All the packets on egress are marked with DEI 0.
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port/subport information. • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information. Defaults Not configured. Command Modes CONF-IF-VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Usage Information Version Description 8.3.10.2 Introduced on the S4810. WARNING: The following message displays to confirm the command: All non-default configurations on the related member ports ports () will be removed. Do you want to continue (y/n)? If you enter “y”, all non-default configurations on any member ports of the current stack group is removed when the unit is rebooted.
vlan-stack compatible Enable the stackable VLAN feature on a VLAN. Syntax vlan-stack compatible To disable the Stackable VLAN feature on a VLAN, use the no vlan-stack compatible command. Defaults Not configured. Command Modes CONF-IF-VLAN Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
vlan-stack dot1p-mapping Map C-Tag dot1p values to a S-Tag dot1p value. You can separate the C-Tag values by commas and dashed ranges are permitted. Dynamic mode CoS overrides any Layer 2 QoS configuration in case of conflicts. Syntax vlan-stack dot1p-mapping c-tag-dot1p values sp-tag-dot1p value Parameters c-tag-dot1p value Enter the keyword c-tag-dot1p then the customer dot1p value that is mapped to a service provider do1p value. The range is from 0 to 7.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. C-Series and S-Series accept both bytes of the 2-byte S-Tag TPID. 8.2.1.0 Introduced on the E-Series ExaScale. 7.6.1.0 Introduced on the C-Series and S-Series.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 8.2.1.0 Introduced on the E-Series ExaScale. C-Series and S-Series accept both bytes of the 2-byte S-Tag TPID. 7.8.1.0 Functionality augmented for C-Series and S-Series to enable multi-purpose use of the port. 7.7.1.0 Functionality augmented for E-Series to enable multi-purpose use of the port. 7.6.1.
! interface Vlan 20 no ip address tagged TenGigabitEthernet 1/23/1 shutdown Dell(conf-if-vl-20)#do show vlan Codes: * - Default VLAN, G - GVRP VLANs Q: U - Untagged, T - Tagged x - Dot1x untagged, X - Dot1x tagged G - GVRP tagged, M - Vlan-stack NUM Status Description * 1 Inactive 20 Active 100 Active Dell(conf-if-vl-20)# Example 2 Q Ports T Te 1/23/1 M Te 1/23/1 Dell(config)#vlan-stack protocol-type 88A8 Dell(config)#interface TenGigabitethernet 3/10/1 Dell(conf-if-te-3/10/1)#no shutdown Dell(conf-if-te-
56 Virtual Routing and Forwarding (VRF) Virtual Routing and Forwarding (VRF) allows multiple instances of a routing table to co-exist on the same router at the same time. ip unknown-unicast Enable IPv4 catch-all route. Syntax ip unknown-unicast To remove the IPv4 catch-all route (0.0.0.0/0) from the LPM route forwarding table in hardware which gets added as a default configuration after the initialization of FIB Agent module, use the no ip unknownunicast command.
Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000. All the default catch-all entries in the longest prefix match (LPM) table collect and transmit all unresolved IPv6 packets to the CPU, even if they are destined for unknown destinations. description Enables you to specify a descriptive name for a customer VRF.
management Use this keyword when you want to associate the interface to the management VRF. Defaults None (Interface is part of default VRF). Command Modes INTERFACE-CONFIG Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.
ip route-export Enables route leaking between VRFs. Exports or shares IPv4 routes corresponding to one VRF with other non-default VRFs. Syntax Parameters ip route-export tag [route-map-name] route-export Enter the keyword to leak or share routes between VRFs. tag Enter a tag (export route target) to expose routes to other VRFs. This tag acts as an identifier for exported routes. You can use this identifier while importing these routes into another non-default VRF.
Parameters route-import Enter the keyword route-import to import routes into the VRF. tag Enter a tag (ASN number) to specify an import route target for importing routes from another VRF. To import leaked routes from another VRF, you must use the same ASN number that is specified as the export route target at the source VRF. route-map-name Enter the name of the route-map to filter the imported routes. NOTE: You must use the route-map attribute while importing routes from the global RTM.
CONFIGURATION Command History Usage Information Version Description 9.7(0.0) Introduced on the S4810, S4820T, S5000, S6000, S6000–ON, and Z9500. You can use the ip route-export tag command without specifying the route-map attribute to export all the routes corresponding to a source VRF. This action exposes source VRF's routes to various other VRFs, which then import these routes using the ip route-import tag command.
Usage Information It is possible to configure multiple import conditions per VRF depending on the exporting VRF. The export-target and import-target support only the match protocol and match prefix-list options. Other options that are configured in the route-maps are ignored. Related Commands ipv6 route-export – exports IPv6 routes to another VRF. match source-protocol Enables you to specify matching criteria while exporting or importing routes.
imported-ospf Enter the keyword imported-ospf to redistribute leaked routes that are learnt using the OSPF protocol. imported-isis Enter the keyword imported-isis to redistribute leaked routes that are learnt using the ISIS protocol. route-map Enter the name of the route-map to specify the filtering criteria for imported routes. Defaults N/A Command Modes CONFIGURATION Command History Related Commands Version Description 9.7(0.
maximum dynamic-routes Specify the maximum number of dynamic (protocol) routes a VRF can have. Syntax maximum dynamic-routes limit {warn-threshold threshold-value | warning-only} To remove the limit on the maximum number of routes used, use the no maximum dynamic-routes command. Parameters limit Maximum number of routes allowed in a VRF. Valid range is from 1 to 16,000 (or maximum allowable for that platform if smaller value).
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S-Series and Z9000.
Version Description 9.4.(0.0) Introduced on the S-Series and Z9000. Usage Information Use this command to display information from the running-config corresponding to either a specific VRF or all the VRFs in the system.
57 VLT Proxy Gateway The Virtual link trucking (VLT) proxy gateway feature allows a VLT domain to locally terminate and route L3 packets that are destined to a L3 end point in another VLT domain. Enable the VLT proxy gateway using the link layer discover protocol (LLDP) method or the static configuration. For more information, refer to Dell Networking OS Command Line Reference Guide. proxy-gateway lldp Enables the proxy-gateway feature using LLDP protocol.
Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, Z9000. Usage Information When proxy-gateway static configuration is added, the setting is saved in the Layer 2 module. When you remove the static proxy gateway configuration, each proxy-gateway static mac configured is deleted from the Layer 2 module.
peer-domain-link port-channel exclude-vlan Configure the VLT port channel, which is connected to remote VLT domain for Proxy Gateway and configure the VLANs that needs to be excluded from VLT Proxy Gateway. S6000–ON Syntax Parameters [no] peer-domain-link port-channel interface-identifier exclude-vlan vlanrange port-channel Configure the proxy-gateway interface port-channel. Port channel range is from 1 to 128. vlan-range Enter the VLAN IDs in which proxy gateway is not needed.
Command History Version Description 9.7(0.0) Introduced on the S6000-ON. 9.7(0.0) Removed the default value on the S-Series and Z-Series. 9.4(0.0) Introduced on the S4810, S4820T, S6000, Z9000, and MXL Switch. Usage Information When a VLT peer goes down, the local VLT node must stop sending its peer’s MAC address. If this timeout is configured, the local VLT node will send its peer's MAC address, till the timer expires. By default this timer value is infinity.
static Command Modes Display details about the static VLT proxy gateway configuration EXEC EXEC Privilege Command History Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S4810, S4820T, S6000, and Z9000.
58 Virtual Link Trunking (VLT) Virtual link trunking (VLT) allows physical links between two chassis to appear as a single virtual link to the network core. VLT eliminates the requirement for Spanning Tree protocols by allowing link aggregation group (LAG) terminations on two separate distribution or core switches, and by supporting a loop-free topology.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.2(0.2) Added support for IPv6. 9.0.2.
Version Description 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.12.0 Introduced on the S4810. Example VLT ARP Statistics ---------------ARP Tunnel Pkts sent:0 ARP Tunnel Pkts Rcvd:0 ARP-sync Pkts Sent:0 ARP-sync Pkts Rcvd:0 ARP Reg Request sent:19 ARP Reg Request rcvd:10 Related Commands show vlt statistics — displays statistics on VLT operations.
Related Commands • after a VLT device is reloaded. • if the Peer VLT device was up at the time the VLTi link failed to the time when it was restored. show vlt statistics — displays statistics on VLT operations. lacp ungroup member-independent Prevent possible loop during the bootup of a VLT peer switch or a device that accesses the VLT domain. Syntax Parameters lacp ungroup member-independent {vlt | port-channel} port-channel Force all LACP port-channel members to become switchports.
Example Dell(conf)#lacp ungroup member-independent ? port-channel LACP port-channel members become switchports vlt All VLT LACP members become switchports multicast peer-routing timeout Configure the time for a VLT node to retain synced multicast routes or synced multicast outgoing interface (OIF) after a VLT peer node failure. Syntax multicast peer-routing timeout value To restore the default value, use the no multicast peer-routing timeout command.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000.
peer-routing-timeout Configure the delay after which peer routing is disabled when the peer is unavailable. This command is applicable for both IPV6/ IPV4. If not configured, peer-routing will not be disabled at all even though the peer is unavailable. Syntax peer-routing-timeout value To restore the default value, use the no peer-routing-timeout command. Parameters value Enter the timeout value in seconds. The range is from 1 to 65535. The default value is infinity.
Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only. 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810.
VLT Peer Status: Version: Local System MAC address: Remote System MAC address: Remote Sytem Version: Delay-Restore timer: Up 5 (1) 00:01:e8:8b:14:3c 00:01:e8:8b:15:20 5 (1) 90 seconds show vlt backup-link Displays information on the backup link operation. Syntax show vlt backup-link Default Not configured. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
igmp-snoop Enter the keywords igmp-snoop to display the igmp-snooping counter information for the VLT. interface Enter the keyword interface to display the interface counter information for the VLT. mac Enter the keyword mac to display the MAC address counter information for the VLT. ndp Enter the keyword ndp to display the VLT counter information for NDP. Default Not configured. Command Modes EXEC Command History This guide is platform-specific.
Example (NDP and Non-VLT ARP) Dell#show vlt counters Total VLT Counters ------------------L2 Total MAC-Address Count: Total Arp Entries Learnt : Total Arp Entries Synced : Total Non-VLT Arp entries Learnt: Total Non-VLT Arp Entries Synced IGMP MRouter Vlans count : IGMP Mcast Groups count : Total VLT Ndp Entries Learnt : Total VLT Ndp Entries Synced : Total Non-VLT Ndp Entries Learnt : Total Non-VLT Ndp Entries Synced : 2 0 0 0 0 2 0 0 0 show vlt detail Displays detailed status information about VLT doma
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Example Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.2(0.2) Introduced on the Z9000, S4810, and S4820T. 9.2(0.0) Introduced on the M I/O Aggregator.
------Parameters ---------Unit-ID Local ----0 Peer ----1 Vlan-config -----------Vlan-ID Local Mode ---------------100 Peer Mode --------- -- L3 Vlan IPV4 Multicast Status -------------------------Vlan-ID Local Status ------------------4094 Peer Status ----------- Active Inactive Dell# Example for Q-in-Q Dell#show vlt mismatch implementation over Domain -----VLT Parameters Local -------------PB for stp Enabled Peer ---Disabled Vlan-type-config ---------------Codes:: P - Primary, C - Community, I
show vlt role Displays the VLT peer status, role of the local VLT switch, VLT system MAC address and system priority, and the MAC address and priority of the local VLT device. Syntax show vlt role Default Not configured. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
arp Display the VLT statistics for ARP. igmp-snoop Display the VLT statistics for IGMP snooping. ndp Display the VLT statistics for NDP. Default Not configured. Command Modes EXEC Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Related Commands Example Version Description 9.7(0.
IGMP PDU Tunnel Pkt rcvd: 10 IGMP Tunnel PDUs sent: 10 IGMP Tunnel PDUs rcvd: 19 VLT Multicast Statistics ------------------------------Info Pkts Sent: 4 Info Pkts Rcvd: 2 Reg Request Sent: 2 Reg Request Rcvd: 2 Reg Response Sent: 1 Reg Response Rcvd: 0 Route updates sent to Peer: 0 Route updates rcvd from Peer: 0 Route update pkts sent to Peer: 0 Route update pkts rcvd from Peer: 0 VLT NDP Statistics -------------------NDP NA VLT Tunnel Pkts sent:16 NDP NA VLT Tunnel Pkts Rcvd:46 NDP NA Non-VLT Tunnel Pkts
IGMP IGMP IGMP IGMP IGMP Reg Response rcvd: 1 PDU Tunnel Pkt sent:5 PDU Tunnel Pkt rcvd:10 Tunnel PDUs sent: 10 Tunnel PDUs rcvd: 19 unit-id Explicitly configure the default unit ID of a VLT peer switch. Syntax unit-id [0 | 1] Parameters 0|1 Configure the default unit ID of a VLT peer switch. Enter 0 for the first peer or enter 1 for the second peer. Defaults Automatically assigned based on the MAC address of each VLT peer.
vlt domain Enable VLT on a switch, configure a VLT domain, and enter VLT-domain configuration mode. Syntax Parameters vlt domain domain-id domain-id Enter the Domain ID number. Configure the same domain ID on the peer switch. The range of domain IDs is from 1 to 1000. Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Version Description 9.7(0.0) Introduced on the S6000-ON. 9.5(0.0) Introduced on the Z9500. 9.0.2.0 Introduced on the S6000. 9.0.0.0 Introduced on the Z9000. 8.3.19.0 Introduced on the S4820T. 8.3.8.0 Introduced on the S4810. 9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in ProgrammableMux (PMUX) mode only.
59 Virtual Extensible LAN (VXLAN) Virtual Extensible LAN (VXLAN) is supported on Dell Networking OS. feature vxlan Enable VXLAN configuration globally on the platform. Syntax feature vxlan To disable the VXLAN, use the no feature vxlan command. Defaults Disabled Command Modes CONFIGURATION Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version Description 9.7(0.
fail-mode Configures failure-mode on the platform. Syntax fail-mode secure To disable the fail-mode secure, use the no fail-mode securecommand. Parameters secure Enter the keyword secure to delete all its database and hardware flows/ resources, when the VTEP loses connectivity with the controller. Defaults non secure Command Modes VXLAN INSTANCE Command History This guide is platform-specific.
Related Commands feature vxlan — Enable VXLAN configuration globally on the platform. vxlan-instance (VAP) To configure a VXLAN-Access Port (VAP) in to VXLAN-instance Syntax vxlan-instance instance ID To unconfigure VAP, use the no vxlan-instance 1 command. Parameters instance ID Enter the VXLAN instance ID. The platform supports only the instance ID 1 in the initial release. Defaults Disabled Command Modes INTERFACE Command History This guide is platform-specific.
Usage Information The retry interval value caps at the value configured on the max-backoff. Related Commands vxlan-instance — Enable VXLAN Instance configuration on the platform. gateway-ip Configures gateway IP address on the platform. Syntax gateway-ip IP address Parameters IP address Enter the IP address of the gateway for the VXLAN instance. Defaults Disabled Command Modes VXLAN INSTANCE Command History This guide is platform-specific.
Command Modes VXLAN INSTANCE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Related Commands Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S6000. vxlan-instance — Enable VXLAN instance configuration on the platform. show vxlan vxlan-instance Displays information related to Network Virtualization Overlay (NVO) Gateway.
show running-config vxlan Displays the configuration information of the VXLAN on S6000. Syntax show running-config vxlan Command Modes Command History • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S6000.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4(0.0) Introduced on the S6000. Example Dell# show vxlan vxlan-instance <1> unicast-mac-remote Total Local Mac Count: 1 VNI MAC TUNNEL 4656 00:00:01:00:00:01 36.1.1.1 Related Commands vxlan-instance- Enable VXLAN Instance configuration on the platform.
4656 4656 Related Commands 00:00:02:00:03:03 00:00:02:00:03:04 Te 1/17/1 Te 1/17/1 0 0 vxlan-instance- Enable VXLAN Instance configuration on the platform. show vxlan vxlan-instance statistics interface Displays the port VLAN statistics information related to Network Virtualization Overlay (NVO) Gateway. Syntax show vxlan vxlan-instance instance ID statisitics interface Parameters Defaults instance ID Enter the VXLAN instance ID. The platform supports only the instance ID 1 in the initial release.
show vxlan vxlan-instance physical-locator Displays physical locators related to Network Virtualization Overlay (NVO) Gateway. Syntax Parameters show vxlan vxlan-instance instance ID physical—locator vtep-ip A.B.C.D instance ID Enter the VXLAN instance ID. The platform supports only the instance ID 1 in the initial release. A.B.C.D Enter the IP address of the VTEP. Defaults Disabled Command Modes VXLAN INSTANCE Command History This guide is platform-specific.
Example Version Description 9.4.(0.0) Introduced on the S6000. Dell#show vxlan vxlan-instance 1 logical-network Instance : 1 Total LN count : 1 Name bffc3be0-13e6-4745-9f6b-0bcbc5877f01 4656 VNID Dell#$n-instance 1 logical-network n 2a8d5d19-8845-4365-ad04-243f0b6df252 Name : 2a8d5d19-8845-4365-ad04-243f0b6df252 Description : Tunnel Key : 2 VFI : 28674 Unknown Multicast MAC Tunnels: 192.168.122.
Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide Version Description 9.7(0.0) Introduced on the S6000-ON. 9.4.(0.0) Introduced on the S6000.
60 Virtual Router Redundancy Protocol (VRRP) Virtual router redundancy protocol (VRRP) is supported by the Dell Networking operating system on Dell Networking OS. IPv4 VRRP Commands The following are IPv4 VRRP commands. advertise-interval Set the time interval between VRRP advertisements. Syntax advertise-interval {seconds | centisecs centisecs } To return to the default settings, use the no advertise-interval command. Parameters seconds Enter a number of seconds. The range is from 1 to 255.
Usage Information Dell Networking recommends keeping the default setting for this command. If you do change the time interval between VRRP advertisements on one router, change it on all routers. authentication-type Enable authentication of VRRP data exchanges. Syntax authentication-type simple [encryption-type] password To delete an authentication type and password, use the no authentication-type command. Parameters simple Enter the keyword simple to specify simple authentication.
Parameters vrrp-id (OPTIONAL) Enter the number of the VRRP group ID. The range is from 1 to 255. ipv6 (OPTIONAL) Enter the keyword ipv6 to clear counters from the IPv6 VRRP group. vrf vrf-name (OPTIONAL) Enter the keyword vrf and then the name of the VRF to clear counters that are maintained on the VRRP operations corresponding to that VRF. Command Modes EXEC Privilege Command History This guide is platform-specific.
bfd Enter the keyword bfd to enable debugging of VRRP BFD interactions. database Enter the keyword database to enable debugging of configuration changes. interface Enter the keyword interface to enable debugging of interface state changes.. ipv6 Enter the keyword ipv6 to enable debugging for IPv6. packets Enter the keyword packets to enable debugging of VRRP control packets. state Enter the keyword state to enable debugging of VRRP state changes.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. disable Disable a VRRP group. Syntax disable To re-enable a disabled VRRP group, use the no disable command. Command Modes VRRP Command History This guide is platform-specific.
Parameters seconds Enter the number of seconds. The range is from 0 to 65535. The default is zero (0) seconds. centisecs centisecs Enter the keyword centisecs then the number of centisecs in units of 25 centisecs . The range is from 0 to 65525 in units of 25 centisecs. Defaults zero (0) seconds or or (0) centiseconds Command Modes VRRP Command History This guide is platform-specific.
Version Description 9.0.2.0 Introduced on the S6000. 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. priority Specify a VRRP priority value for the VRRP group. The VRRP protocol uses this value during the MASTER election process. Syntax priority priority To return to the default value, use the no priority command.
show config View the non-default VRRP configuration. Syntax Parameters show config [verbose] verbose (OPTIONAL) Enter the keyword verbose to view all VRRP group configuration information, including defaults. Command Modes VRRP Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command.
• Command Modes Command History For a VLAN interface, enter the keyword vlan then the VLAN ID. The VLAN ID range is from 1 to 4094. brief (OPTIONAL) Enter the keyword brief to view a table of information on the VRRP groups. ipv6 (OPTIONAL) Enter the keyword ipv6 to view only VRRP IPv6 groups. • EXEC • EXEC Privilege This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.
Item Description Virtual addr(s) Displays the virtual IP addresses of the VRRP routers associated with the interface. Example (Brief) Dell>Interface Grp Pri Pre State Master addr Virtual addr(s) Description-----------------------------------------------------------Te 1/3/1 1 100 Y Master 200.200.200.200 200.200.200.201 Te 1/3/1 2 100 Y Master 200.200.200.200 200.200.200.202 200.200.200.203 Description Te 1/3/1 3 100 Y Master 1.1.1.1 1.1.1.2 Te 1/3/1 4 100 Y Master 200.200.200.200 200.200.200.206 200.
Example Dell>show vrrp -----------------TenGigabitEthernet 1/1/3, VRID: 1, Net: 10.1.1.253 State: Master, Priority: 105, Master: 10.1.1.253 (local) Hold Down: 0 sec, Preempt: TRUE, AdvInt: 1 sec Adv rcvd: 0, Adv sent: 1862, Gratuitous ARP sent: 0 Virtual MAC address: 00:00:5e:00:01:01 Virtual IP address: 10.1.1.252 Authentication: (none) Tracking states for 1 interfaces: Up TenGigabitEthernet 1/1/4 priority-cost 10 -----------------TenGigabitEthernet 1/4/1, VRID: 2, Net: 10.1.2.
Usage Information Version Description 9.0.2.0 Introduced on the S6000. 7.6.1.0 Introduced on the S-Series (S50 only). 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. If the interface is disabled, the cost value is subtracted from the priority value and forces a new MASTER election if the priority value is lower than the priority value in the BACKUP virtual routers. virtual-address Configure up to 12 IP addresses of virtual routers in the VRRP group.
Usage Information The VRRP group only becomes active and sends VRRP packets when a virtual IP address is configured. When you delete the virtual address, the VRRP group stops sending VRRP packets. A system message appears after you enter or delete the virtual-address command. To guarantee that a VRRP group becomes MASTER, configure the VRRP group’s virtual address with the same IP address as the interface’s primary IP address and change the priority of the VRRP group to 255.
Parameters seconds Enter the number of seconds for the delay. The range is from 0 to 900 (0 indicates no delay). Defaults 0 Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 9.0.2.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.11.1 Introduced on the Z9000. 8.3.7.0 Introduced on the S4810. 7.6.1.0 Introduced on the S-Series. 7.5.1.0 Introduced on the C-Series. 6.2.1.1 Introduced on the E-Series. Usage Information The VRRP group only becomes active and sends VRRP packets when a virtual IP address is configured. When you delete the virtual address, the VRRP group stops sending VRRP packets.
3. Set all the switches from both to version 3. NOTE: Do not run VRRP version 2 and version 3 in the same group for an extended period of time. Example Dell(conf-if-te-1/1/1-vrid-100)#version ? 2 VRRPv2 3 VRRPv3 both Interoperable, send VRRPv3 receive both Dell(conf-if-te-1/1/1-vrid-100)#version 3 IPv6 VRRP Commands The following are IPv6 VRRP commands.
Version Description 8.3.19.0 Introduced on the S4820T. 8.3.10.0 Introduced on the S4810. 8.4.1.0 Introduced on E-Series ExaScale, C-Series, and S-Series. Support was added for IPv6 VRRP groups in non-default VRF instances. 8.3.2.0 Introduced on the E-Series TeraScale. debug vrrp ipv6 Allows you to enable debugging of VRRP.
Usage Information If no options are specified, debug is active on all interfaces and all VRRP groups. show vrrp ipv6 View the IPv6 VRRP groups that are active. If no VRRP groups are active, the Dell Networking OS returns No Active VRRP group. Syntax Parameters Command Modes Command History show vrrp ipv6 [vrid] [interface] [brief] [vrf vrf-name] vrid (OPTIONAL) Enter the virtual router identifier for the VRRP group to view only that group. The range is from 1 to 255.
Line Beginning with Description • master (MASTER virtual router). • backup (BACKUP virtual router). the interface’s priority and the IP address of the MASTER. Hold Down:... Adv rcvd:... Example This line displays additional VRRP configuration information: • Hold Down displays the hold down timer interval in seconds. • Preempt displays TRUE if preempt is configured and FALSE if preempt is not configured. • AdvInt displays the Advertise Interval in seconds.
Parameters vrid Enter the virtual-router ID number of the VRRP group. The VRID range is from 1 to 255. Defaults Not configured. Command Modes INTERFACE Command History This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide. The following is a list of the Dell Networking OS version history for this command. Usage Information Version Description 9.7(0.0) Introduced on the S6000-ON. 8.4.2.