FAQ

DellEmc Diag poetool - version x.x package x.xx.x.x-x 2019/01/07
DellEmc Diag rtctool - version x.x package x.xx.x.x-x 2019/01/07
DellEmc Diag smbiostool - version x.x package x.xx.x.x-x 2019/01/07
DellEmc Diag storagetool - version x.x package x.xx.x.x-x 2019/01/07
DellEmc Diag temptool - version x.x package x.xx.x.x-x 2019/01/07
Testing I2C devices:
Checking I2C devices on bus 0:
+ Checking Thermal 0x4a ..... Passed
+ Checking System CPLD 0x21 ..... Passed
+ Checking ID EEPROM Block 1 0x50 ..... Passed
+ Checking ID EEPROM Block 2 0x51 ..... Passed
+ Checking ID EEPROM Block 3 0x52 ..... Passed
+ Checking ID EEPROM Block 4 0x53 ..... Passed
+ Checking ID EEPROM Block 5 0x54 ..... Passed
+ Checking ID EEPROM Block 6 0x55 ..... Passed
+ Checking ID EEPROM Block 7 0x56 ..... Passed
+ Checking ID EEPROM Block 8 0x57 ..... Passed
I2C Devices: Overall test results --------------- >>> Passed
Testing Temp sensor devices:
+ Checking [Thermal sensor] = 43.0 C ............. Passed
Temp Sensors: Overall test results -------------- >>> Passed
PL Tool test:
System CPLD: LED Control Reg Reg Addr: 0x43 ...........Passed
Overall Test Results: Passed
Show Optics in System
Port # Name Status Type Part Number Rev Serial Number
------ ------------ ------ ------- ---------- --- ---------------
1 SFP 1 PRESENT None 616740000 C CN0C6Y7M65Q8WP3
2 SFP 2 PRESENT None 616740000 C CN0C6Y7M65Q8WP3
Testing Memory Regions:
Testing Memory Region 0:
Address Read Test ......................................... Passed
Address Write Test ........................................ Passed
Address Walking 1's Test .................................. Passed
Address Walking 0's Test .................................. Passed
Data Read Test ............................................ Passed
Data Write Test ........................................... Passed
Data Walking 1's Test ..................................... Passed
Data Walking 0's Test ..................................... Passed
Data Sliding 1's Test ..................................... Passed
Data Sliding 0's Test ..................................... Passed
Data Pattern Test ......................................... Passed
Memory: Overall test results -------------------------- >>> Passed
MAC Addr Test ........................................... Passed
Mounted Filesystem Devices:
DMA pool size: 8388608
AXI unit 0: Dev 0x8443, Rev 0x11, Chip BCM53443_B0, Driver BCM56160_A0
sysconf_probe successful
global_sal_config successful
*** 1 BCM devices are detected
SOC unit 0 attached to PCI device BCM53443_B0
Current mode is now ESW
12
ONIE diagnostics