Install Guide

1 Serial Console
2 Master LED
3 Power LED
4 Fan Status LED
5 Locator LED
6 Stack ID
7 USB-A
8 USB-B Console
9 Management
LED behavior
The following S6000–ON system LED behavior is seen during ONIE operations:
Table 1. LED behavior
LED Description
System Status LED
O—no power
Blinking green—booting or system is in Diagnostic mode
Solid green—normal operation
Solid red—critical alarm
Blinking red—noncritical alarm
Master LED
Solid green—system is in Stacking Master mode
O—system is in Slave mode
Fan LED
Solid green—fan is powered on and running at the expected
RPM
Solid yellow—fan failed including incompatible airow direction
Power Status LED
O—no power
Solid green—normal operations
Blinking yellow—a power supply has failed
Locator LED
O—locator function is disabled
Blinking blue—locator function is enabled
Prerequisite
The following is a list of components required for a successful installation of the S6000-ON.
NOTE
: Detailed installation instructions for the S6000-ON are provided in Site Preparations and Install the S6000-ON.
S6000–ON chassis
AC cables to connect the AC power source to each of the chassis’ AC power supplies (country/regional congured)
Mounting brackets for rack installation (included)
Screws for rack installation and #1 and #2 Phillips screwdrivers (not included)
Ground cable (not included, optional)
Ground cable screws (included)
The S6000–ON system
9