NOTE: Because DCBx TLV processing is best effort, it is possible that CIN frames may be processed when DCBx is
configured to operate in CEE mode and vice versa. In this case, the unrecognized TLVs cause the unrecognized TLV
counter to increment, but the frame is processed and is not discarded.
Legacy DCBx (CIN and CEE) supports the DCBx control state machine that is defined to maintain the sequence number and acknowledge
the number sent in the DCBx control TLVs.
DCBx Example
The following figure shows how to use DCBx.
The external 40GbE ports on the base module (ports 33 and 37) of two switches are used for uplinks configured as DCBx auto-upstream
ports. The device is connected to third-party, top-of-rack (ToR) switches through uplinks. The ToR switches are part of a Fibre Channel
storage network.
The internal ports (ports 1-32) connected to the 10GbE backplane are configured as auto-downstream ports.
Figure 35. DCBx Sample Topology
DCBx Prerequisites and Restrictions
The following prerequisites and restrictions apply when you configure DCBx operation on a port:
For DCBx, on a port interface, enable LLDP in both Send (TX) and Receive (RX) mode (the protocol lldp mode command; refer
to the example in in the chapter). If multiple DCBx peer ports are detected on a local DCBx interface, LLDP is shut down.
The CIN version of DCBx supports only PFC, ETS, and FCOE; it does not support iSCSI, backward congestion management (BCN),
logical link down (LLDF), and network interface virtualization (NIV).
Configuring DCBx
To configure DCBx, follow these steps.
For DCBx, to advertise DCBx TLVs to peers, enable LLDP. For more information, refer to .
1. Configure ToR- and FCF-facing interfaces as auto-upstream ports.
2. Configure server-facing interfaces as auto-downstream ports.
3. Configure a port to operate in a configuration-source role.
4. Configure ports to operate in a manual role.
1. Enter INTERFACE Configuration mode.
CONFIGURATION mode
264