Concept Guide
Conguring SNMP traps for new MAC learning or 
station–move
You can congure the system to send SNMP MAC notications from the Dell EMC Networking OS.
To congure the system to send SNMP MAC-notications, use the following command:
• Enable MAC-notication traps.
CONFIGURATION mode
snmp-server traps mac-notification
– Trap messages are generated only for the new MAC and for the MAC that is learnt for the rst time in the system. If same MAC is 
learnt on dierent vlan–ids, then the system does not generate trap messages.
– If station–move is detected within 3 seconds, then the system generates station–move trap messages and beyond 3 seconds, you 
cannot see any SYSLOG messages in the system. In continuous station–move, the system generates only 4 station–move trap 
messages and after every 1 minute, the system generates SYSLOG/trap messages.
– If there is MAC ooding, only 50 MACs are covered in the trap messages in 1 second and other MAC’s learnt in the system are 
processed in the next cycle.
NOTE: For the VLT-LAG interfaces, the snmp-server traps mac-notification command should be enabled on 
both the interfaces. If the command is congured only on one VLT node, then you cannot see any VLT mismatch in the 
system. The snmp-server traps mac-notification is not visible under ICL interface and no TRAPS are 
supported.
Manage VLANs using SNMP
The qBridgeMIB managed objects in Q-BRIDGE-MIB, dened in RFC 2674, allows you to use SNMP to manage VLANs.
Creating a VLAN
To create a VLAN, use the dot1qVlanStaticRowStatus object.
The snmpset operation shown in the following example creates VLAN 10 by specifying a value of 4 for instance 10 of the 
dot1qVlanStaticRowStatus object.
Example of Creating a VLAN using SNMP
> snmpset -v2c -c mycommunity 123.45.6.78 .1.3.6.1.2.1.17.7.1.4.3.1.5.10 i 4
SNMPv2-SMI::mib-2.17.7.1.4.3.1.5.10 = INTEGER: 4
Assigning a VLAN Alias
Write a character string to the dot1qVlanStaticName object to assign a name to a VLAN.
Example of Assigning a VLAN Alias using SNMP
[Unix system output]
> snmpset -v2c -c mycommunity 10.11.131.185 .1.3.6.1.2.1.17.7.1.4.3.1.1.1107787786 s "My
VLAN"
SNMPv2-SMI::mib-2.17.7.1.4.3.1.1.1107787786 = STRING: "My VLAN"
[Dell system output]
DellEMC#show int vlan 10
Vlan 10 is down, line protocol is down
Vlan alias name is: My VLAN
Address is 00:01:e8:cc:cc:ce, Current address is 00:01:e8:cc:cc:ce
Interface index is 1107787786
Simple Network Management Protocol (SNMP)
945