Install Guide

Table Of Contents
Specifications
This topic lists the S6100ON specifications.
CAUTION: Operate the product at an ambient temperature not higher than 113°F (45°C).
CAUTION: Lithium Battery Caution: There is a danger of explosion if the battery is incorrectly replaced.
Replace only with same or equivalent type of battery. Dispose of the batteries according to the manufacturer's
instructions.
NOTE: For RoHS information, see Restricted Material Compliance.
Topics:
Chassis physical design
IEEE standards
Agency compliance
USA Federal Communications Commission (FCC) statement
European Union EMC Directive Conformance statement
Japan: VCCI Compliance for Class A Equipment
Korean Certification of Compliance
Safety Standards and Compliance Agency Certifications
Electromagnetic Compatibility (EMC)
Product recycling and disposal
Chassis physical design
Table 10. Chassis physical design
Parameter Specifications
Height 3.50 inches (88.9 mm)
Width 17.1 inches (434.3 mm)
Depth 18 inches (457.2 mm)
Chassis Weight with Factory-Installed Components 44 lbs (20 kg)with two PSUs and four I/O modules
Rack Clearance Required
Front: 5 inches (12.7 cm)
Rear: 5 inches (12.7 cm)
Table 11. Environmental Parameters
Parameter Specifications
Operating Temperature 32° to 113°F (0° to 45°C)
Operating Humidity 5 to 95 percent (RH), non-condensing
Storage Temperature 40° to 158°F (40° to 70°C)
Storage Humidity 5 to 95 percent, non-condensing
Thermal Output
Typical: 1170.4 BTU/hr (343 W)
Maximum: 3057.3 BTU/hr (896 W)