Install Guide
Table Of Contents
- Dell EMC PowerSwitch S6100-ON Installation Guide March 2021
 - About this guide
 - S6100–ON system
 - Site preparations
 - NEBS compliance
 - S6100–ON installation
 - Power supplies
 - Fans
 - Management ports
 - Dell support
 - Specifications
- Chassis physical design
 - IEEE standards
 - Agency compliance
 - USA Federal Communications Commission (FCC) statement
 - European Union EMC Directive Conformance statement
 - Japan: VCCI Compliance for Class A Equipment
 - Korean Certification of Compliance
 - Safety Standards and Compliance Agency Certifications
 - Electromagnetic Compatibility (EMC)
 - Product recycling and disposal
 
 
Table 11. Environmental Parameters (continued)
Parameter Specifications
Maximum operational altitude 10,000 feet (3,048 meters)
Maximum non-operational altitude No performance degradation to 35,000 feet (10,668 meters)
Shock SV0115 — ODM
Table 12. AC power requirements 
Parameter Specifications
Power Supply 100–240 VAC 50/60 Hz
Maximum Current Draw Per System 12A–6.5A @ 100–240 VAC
PSU Maximum Power Capability 1100 Watts
Typical and Maximum Power Consumption
343 Watts typical
896 Watts maximum
Reliability MTBF 1,154,397 hours
Table 13. DC power requirements 
Parameter Specifications
PSU Maximum Power Capability 1100 Watts
PSU Maximum current required 32A
Minimum and maximum input voltage range −40.5 V / −48 V/ −60 V
Input power at full load
−40.5 V/970 W −48 V/930 W −60 V/950 W, without fan
−40.5 V/980 W −48 V/940 W −60V/ 960 W, with fan
Input current at full load
−40.5V/23.8A −48V/19.0A −60V/ 15.6A, without fan
−40.5V/24.0A −48V/19.2A −60V/ 16.0A, with fan
Start up VDC 39.0+/−1.5 V
Start off VDC 37.5+/−1.5 V
IEEE standards
The S6100–ON complies with the following IEEE standards:
● 802.3ab Gigabit Ethernet (1000BASE-T)
● 802.3ae 10 Gigabit Ethernet (10GBASE-X)
● 802.3ba 40 Gigabit Ethernet (40GBase-SR4, 40GBase-CR4) on optical ports
● 802.3ba 100 Gigabit Ethernet
● 802.3bj 100 Gigabit Ethernet
● 802.3bm 100 Gigabit Ethernet
44