Users Guide

----------------------------------------------------
1 1 36
1 2 38
1 3 36
1 4 37
-- Thermal Sensor Readings (deg C) --
Unit CpuOnBoard Bcm56960 Bcm56960 Bcm56960 SwitchOn FP-GE FP-SFP+ Bcm_Int Cpu_Int
---------------------------------------------------------------------------------
1 32 36 32 38 34 34 31 53 30
Dell#
Dell#show environment fan
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed
------------------------------------------
1 1 up up 7680
1 2 up up 7710
1 3 up up 7605
1 4 up up 7635
Speed in RPM
Dell#
Dell#show environment thermal-sensor
-- Thermal Sensor Readings (deg C) --
Unit CpuOnBoard Bcm56960 Bcm56960 Bcm56960 SwitchOn FP-GE FP-SFP+ Bcm_Int Cpu_Int
---------------------------------------------------------------------------------
1 32 36 32 38 34 34 31 52 29
Dell#
show inventory
Display the switch type, components (including media), and Dell Networking Operating System (OS), including hardware
identification numbers and configured protocols.
Syntax
show inventory [media slot]
Parameters
media
slot
(OPTIONAL) Enter the keyword media then the stack ID of the stack member for
which you want to display pluggable media inventory.
NOTE: This parameter is available but not supported in Dell Networking
Operating System version 8.3.11.4. Because stacking is not supported, if you
use this parameter, the output displays Media not present or accessible
(refer to the Usage Information section).
Defaults none
Command Modes CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
Networking OS Command Line Reference Guide.
Version Description
9.10(0.0) Introduced on the S6100-ON.
9.8(1.0) Introduced on the Z9100ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
114 Control and Monitoring