Users Guide

Line Description
Voltage High
Alarm Flag
This can be either true or false, depending on the Current Temperature value
displayed above.
Tx Bias High
Alarm Flag
This can be either true or false, depending on the present Tx bias current value
displayed above.
Tx Power High
Alarm Flag
This can be either true or false, depending on the Current Tx bias power value
displayed above.
Rx Power High
Alarm Flag
This can be either true or false, depending on the Current Rx power value displayed
above.
Temperature Low
Alarm Flag
This can be either true or false, depending on the Current Temperature value
displayed above.
Voltage Low
Alarm Flag
This can be either true or false, depending on the Current voltage value displayed
above.
Tx Bias Low
Alarm Flag
This can be either true or false, depending on the Tx bias current value displayed
above.
Tx Power Low
Alarm Flag
This can be either true or false, depending on the Current Tx power value displayed
above.
Rx Power Low
Alarm Flag
This can be either true or false, depending on the Current Rx power value displayed
above.
Temperature
High Warning
Flag
This can be either true or false, depending on the Current Temperature value
displayed above.
Voltage High
Warning Flag
This can be either true or false, depending on the Current Voltage value displayed
above.
Tx Bias High
Warning Flag
This can be either true or false, depending on the Tx bias current value displayed
above.
Tx Power High
Warning Flag
This can be either true or false, depending on the Current Tx power value displayed
above.
Rx Power High
Warning Flag
This can be either true or false, depending on the Current Tx power value displayed
above.
Temperature Low
Warning Flag
This can be either true or false, depending on the Current Temperature value
displayed above.
Voltage Low
Warning Flag
This can be either true or false, depending on the Current Voltage value displayed
above.
Tx Bias Low
Warning Flag
This can be either true or false, depending on the present Tx bias current value
displayed above.
Tx Power Low
Warning Flag
This can be either true or false, depending on the Current Tx power value displayed
above.
Rx Power Low
Warning Flag
This can be either true or false, depending on the Current Rx power value displayed
above.
Example
Dell# show interfaces TenGigabitEthernet 1/4/7/1 transceiver
Interface Name : TenGigabitEthernet 1/4/7/1
QSFP 4/7/1 Serial ID Base Fields
QSFP 4/7/1 Id = 0x0d
QSFP 4/7/1 Ext Id = 0x00
QSFP 4/7/1 Connector = 0x0c
QSFP 4/7/1 Transceiver Code = 0x04 0x00 0x00 0x00 0x00
0x00 0x00 0x00
QSFP 4/7/1 Encoding = 0x05
QSFP 4/7/1 Length(SFM) Km = 0x00
QSFP 4/7/1 Length(OM3) 2m = 0x32
594 Interfaces