Users Guide

Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.11(0.0) Added support to display 10GBASE-T information on the S4048, S4048T, S6000, S6000-
ON, S6100, Z9500, S6010, and Z9100.
9.10(0.0) Introduced on the S6100-ON.
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
9.0.0.0 Introduced on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.3.11.4 Output expanded to include Piece Part ID (PPID) and eSR4 optics.
8.3.11.1 Introduced on the Z9000.
7.6.1.0 Introduced this version of the command for S-Series. S-Series output diers from E-
Series.
Usage Information
If there are no ber ports in the unit, just the header under show inventory media displays. If there are ber ports
but no optics inserted, the output displays Media not present or accessible.
The explanation for the elds present in the show inventory optional-module command example, are below:
CurrentConf – Module type conguration as present in the current running cong.
Inserted – Module type actually present in the slot.
BootTimeConf - Module type conguration that existed in the startup cong at the time of boot up.
Example (S6100–
ON)
Dell#show inventory
System Type : S6100-ON
System Mode : 1.0
Software Version : 9-8(1-53)
Unit Type Serial Number Part Number Rev Piece Part ID Rev Svc Tag Exprs Svc Code
------------------------------------------------------------------------------------------------------------
* 1 S6100-ON-01-FE-66/34 NA N/A N/A N/A 0
1 S6100-MOD-16xETH40-F NA N/A N/A N/A 0
1 S6100-MOD-16xETH40-F NA N/A N/A N/A 0
1 S6100-MOD-16xETH40-F NA N/A N/A N/A 0
1 S6100-MOD-16xETH40-F NA N/A N/A N/A 0
1 S6100-ON-FAN-R NA N/A N/A N/A 0
1 S6100-ON-FAN-R NA N/A N/A N/A 0
1 S6100-ON-FAN-R NA N/A N/A N/A 0
* - Management Unit
Software Protocol Configured
--------------------------------------------------------------
DCBX
SNMP
Dell#show inventory media
Slot Port Type Media Serial Number Dell Qualified
-----------------------------------------------------------------------------------
1 1/1 QSFP 40GBASE-CR4-1M CN0NWGTV32G4901 Yes
1 1/2 Media not present or accessible
1 1/3 Media not present or accessible
1 1/4 QSFP 40GBASE-CR4-1M CN05NP8R3822DKN Yes
1 1/5 QSFP 40GBASE-CR4-1M CN05NP8R3822EJ5 Yes
1 1/6 QSFP 40GBASE-CR4-1M CN05NP8R3538348 Yes
1 1/7 Media not present or accessible
1 1/8 Media not present or accessible
1 1/9 QSFP 40GBASE-CR4-1M CN0NWGTV32G4903 Yes
128 Control and Monitoring