Users Guide

Recognize an Under-Voltage Condition
If the system detects an under-voltage condition, it sends an alarm.
To recognize this condition, look for the following system message: .
This message indicates that the specied card is not receiving enough power. In response, the system rst shuts down Power over
Ethernet (PoE). If the under-voltage condition persists, line cards are shut down, then the RPMs.
Troubleshoot an Under-Voltage Condition
To troubleshoot an under-voltage condition, check that the correct number of power supplies are installed and their Status light emitting
diodes (LEDs) are lit.
The following table lists information for SNMP traps and OIDs on the environmental monitoring hardware and hardware components.
Table 113. SNMP Traps and OIDs
OID String OID Name Description
Receiving Power
.1.3.6.1.4.1.6027.3.10.1.2.5.1.6 chSysPortXfpRecvPower OID displays the receiving power of the
connected optics.
Transmitting power
.1.3.6.1.4.1.6027.3.10.1.2.5.1.8 chSysPortXfpTxPower OID displays the transmitting power of the
connected optics.
Temperature
.1.3.6.1.4.1.6027.3.10.1.2.5.1.7 chSysPortXfpRecvTemp OID displays the temperature of the
connected optics.
NOTE: These OIDs only generate if
you enable the enable optic-
info-update-interval is
enabled command.
Hardware MIB Buer Statistics
.1.3.6.1.4.1.6027.3.27.1.4 dellNetFpPacketBuerTable View the modular packet buers details per
stack unit and the mode of allocation.
.1.3.6.1.4.1.6027.3.27.1.5 dellNetFpStatsPerPortTable View the forwarding plane statistics
containing the packet buer usage per port
per stack unit.
.1.3.6.1.4.1.6027.3.27.1.6 dellNetFpStatsPerCOSTable View the forwarding plane statistics
containing the packet buer statistics per
COS per port.
Buer Tuning
Buer Tuning allows you to modify the way your switch allocates buers from its available memory and helps prevent packet drops during a
temporary burst of trac.
Using a PreDened Buer Prole
1052
Debugging and Diagnostics