Users Guide

VLAN, the frames are tagged with the respective Layer 3 VLAN ID. For example, in the conguration source TenGig 11/6/1 destination
TeGig 11/6/2 direction tx, if the MD port TenGig 11/6/1 is an untagged member of any VLAN, all monitored frames that the MG port TeGig
11/6/2 receives are tagged with the VLAN ID of the MD port. Similarly, if BPDUs are transmitted, the MG port receives them tagged with
the VLAN ID 4095. This behavior might result in a dierence between the number of egress packets on the MD port and monitored
packets on the MG port.
Dell Networking OS Behavior: The platform continues to mirror outgoing trac even after an MD participating in spanning tree protocol
(STP) transitions from the forwarding to blocking.
Conguring Port Monitoring
To congure port monitoring, use the following commands.
1 Verify that the intended monitoring port has no conguration other than no shutdown, as shown in the following example.
EXEC Privilege mode
show interface
2 Create a monitoring session using the command monitor session from CONFIGURATION mode, as shown in the following example.
CONFIGURATION mode
monitor session
monitor session type rpm/erpm
type is an optional keyword, required only for rpm and erpm
3 Specify the source and destination port and direction of trac, as shown in the following example.
MONITOR SESSION mode
source
Example of Viewing Port Monitoring Conguration
To display information on currently congured port-monitoring sessions, use the show monitor session command from EXEC
Privilege mode.
Dell(conf)#monitor session 0
Dell(conf-mon-sess-0)#$source ten 1/1/1/1 dest ten 1/1/1/2 dir rx
Dell(conf-mon-sess-0)#show c
!
monitor session 0
source TenGigabitEthernet 1/1/1/1 destination TenGigabitEthernet 1/1/1/2 direction rx
Dell(conf-mon-sess-0)#
Dell(conf-mon-sess-0)#do show monitor session
SessID Source Destination Dir Mode Source IP Dest IP DSCP TTL Drop Rate
Gre-Protocol FcMonitor
------ ------ ------------ --- ---- --------- -------- ---- --- ---- ----
----------- ---------
0 Te 1/1/1/1 Te 1/1/1/2 rx Port 0.0.0.0 0.0.0.0 0 0 No N/
A N/A No
Dell(conf)#monitor session 0
Dell(conf-mon-sess-0)#source po 10 dest ten 1/2/1 dir rx
Dell(conf-mon-sess-0)#do show monitor session
SessID Source Destination Dir Mode Source IP Dest IP DSCP TTL Drop
Rate Gre-Protocol FcMonitor
------ ------ ----------- --- ---- --------- -------- ---- --- ----
---- ----------- ---------
0 Te 1/1/1/1 Te 1/1/1/2 rx Port 0.0.0.0 0.0.0.0 0 0 No N/
A N/A No
0 Po 10 Te 1/1/1/2 rx Port 0.0.0.0 0.0.0.0 0 0 No N/
A N/A No
Dell(conf)#monitor session 1
Dell(conf-mon-sess-1)#source vl 40 dest ten1/1/1/31 dir rx
Dell(conf-mon-sess-1)#flow-based enable
Port Monitoring
661