Users Guide
8  Congure the VLT links between VLT peer 1 and VLT peer 2 to the top of rack unit (shown in the following example).
9  Congure the static LAG/LACP between ports connected from VLT peer 1 and VLT peer 2 to the top of rack unit.
EXEC Privilege mode
show running-config entity
10  Congure the VLT peer link port channel id in VLT peer 1 and VLT peer 2.
EXEC mode or EXEC Privilege mode
show interfaces interface
11  In the top of rack unit, congure LACP in the physical ports.
EXEC Privilege mode
show running-config entity
12  Verify that VLT is running.
EXEC mode
show vlt brief or show vlt detail
13  Verify that the VLT LAG is running in both VLT peer units.
EXEC mode or EXEC Privilege mode
show interfaces interface
Example of Conguring VLT
In the following sample VLT conguration steps, VLT peer 1 is Dell-2, VLT peer 2 is Dell-4, and the ToR is S60-1.
NOTE
: If you use a third-party ToR unit, Dell Networking recommends using static LAGs with VLT peers to avoid potential 
problems if you reboot the VLT peers.
Congure the VLT domain with the same ID in VLT peer 1 and VLT peer 2.
Dell-2(conf)#vlt domain 5
Dell-2(conf-vlt-domain)#
Dell-4(conf)#vlt domain 5
Dell-4(conf-vlt-domain)#
Congure the VLTi between VLT peer 1 and VLT peer 2.
1 You can congure the LACP/static LAG between the peer units (not shown).
2 Congure the peer-link port-channel in the VLT domains of each peer unit.
Dell-2(conf)#interface port-channel 1
Dell-2(conf-if-po-1)#channel-member TenGigabitEthernet 1/1/4/1-1/1/4/4
Dell-4(conf)#interface port-channel 1
Dell-4(conf-if-po-1)#channel-member TenGigabitEthernet 1/1/4/1-1/1/4/4
Congure the backup link between the VLT peer units.
1 Congure the peer 2 management ip/ interface ip for which connectivity is present in VLT peer 1.
2 Congure the peer 1 management ip/ interface ip for which connectivity is present in VLT peer 2.
Congure the VLT links between VLT peer 1 and VLT peer 2 to the Top of Rack unit. In the following example, port Te 1/1/4/1 in VLT peer 1 
is connected to Te 1/1/8/1 of ToR and port Te 1/1/5/1 in VLT peer 2 is connected to Te 1/1/3/1 of ToR.
1 Congure the static LAG/LACP between the ports connected from VLT peer 1 and VLT peer 2 to the Top of Rack unit.
2 Congure the VLT peer link port channel id in VLT peer 1 and VLT peer 2.
3 In the Top of Rack unit, congure LACP in the physical ports (shown for VLT peer 1 only. Repeat steps for VLT peer 2. The bold vlt-
peer-lag port-channel 2 indicates that port-channel 2 is the port-channel id congured in VLT peer 2).
Dell-2#show running-config interface tengigabitethernet 1/1/4/1
!
Virtual Link Trunking (VLT)
945










