Users Guide
falling-threshold
value event-number
Enter the keywords falling-threshold then the value (64 bit) the falling-threshold
alarm is either triggered or reset. Then enter the event-number to trigger when the falling
threshold exceeds its limit. This value is the same as the alarmFallingEventIndex or the
alarmTable of the RMON MIB. If there is no corresponding falling-threshold event, the
value is zero.
owner string (OPTIONAL) Enter the keyword owner then the owner name to specify an owner for the
alarm. This is the alarmOwner object in the alarmTable of the RMON MIB.
Defaults owner
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.10(0.0) Introduced on the S6100-ON.
9.8(1.0) Introduced on the Z9100-ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
6.1.1.0 Introduced on the E-Series.
show rmon
Display the RMON running status including the memory usage.
Syntax
show rmon
Defaults none
Command Modes EXEC
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Remote Monitoring (RMON) 1309