Users Guide
MIB Support for 25G, 40G, 50G, 100G Optical
Transceiver or DAC cable IDPROM user info
Dell EMC Networking provides MIB objects to display the information for 25G, 40G, 50G, 100G Optical Transceiver or DAC cable IDPROM.
The following table lists the related MIB objects, OID and description for the same:
Table 100. MIB Objects to Display support for 25G, 40G, 50G, 100G Optical Transceiver or DAC cable IDPROM user info
MIB Object OID Description
dellNetIfTransceiverData 1.3.6.1.4.1.6027.3.11.1.3 Species the Transceiver Data Main
dellNetIfTransceiverDataTable 1.3.6.1.4.1.6027.3.11.1.3.1 Species the Transceiver Data Table
dellNetIfTransceiverDataEntry 1.3.6.1.4.1.6027.3.11.1.3.1.1 Species the Transceiver Data Entry Point
dellNetIfTransDeviceName 1.3.6.1.4.1.6027.3.11.1.3.1.1.1 Species the Transceiver Device name
dellNetIfTransPort 1.3.6.1.4.1.6027.3.11.1.3.1.1.2 Species the Transceiver Port Name
dellNetIfTransOpticsPresent 1.3.6.1.4.1.6027.3.11.1.3.1.1.3 Species whether Optics is present in the
Port or not
dellNetIfTransOpticsType 1.3.6.1.4.1.6027.3.11.1.3.1.1.4 Species the Optic Type inserted
dellNetIfTransVendorName 1.3.6.1.4.1.6027.3.11.1.3.1.1.5 Species the Vendor Name of the Optic
inserted
dellNetIfTransPartNumber 1.3.6.1.4.1.6027.3.11.1.3.1.1.6 Species the Part Number of the Optic
inserted
dellNetIfTransSerialNumber 1.3.6.1.4.1.6027.3.11.1.3.1.1.7 Species the Serial Number of the Optic
inserted
dellNetIfTransTransmitPowerLane1 1.3.6.1.4.1.6027.3.11.1.3.1.1.8 Species Lane 1 Tx power value in dBm
dellNetIfTransTransmitPowerLane2 1.3.6.1.4.1.6027.3.11.1.3.1.1.9 Species Lane 2 Tx power value in dBm
dellNetIfTransTransmitPowerLane3 1.3.6.1.4.1.6027.3.11.1.3.1.1.10 Species Lane 3 Tx power value in dBm
dellNetIfTransTransmitPowerLane4 1.3.6.1.4.1.6027.3.11.1.3.1.1.11 Species Lane 4 Tx power value in dBm
dellNetIfTransReceivePowerLane1 1.3.6.1.4.1.6027.3.11.1.3.1.1.12 Species Lane 1 Rx power value in dBm
dellNetIfTransReceivePowerLane2 1.3.6.1.4.1.6027.3.11.1.3.1.1.13 Species Lane 2 Rx power value in dBm
dellNetIfTransReceivePowerLane3 1.3.6.1.4.1.6027.3.11.1.3.1.1.14 Species Lane 3 Rx power value in dBm
dellNetIfTransReceivePowerLane4 1.3.6.1.4.1.6027.3.11.1.3.1.1.15 Species Lane 4 Rx power value in dBm
dellNetIfTransTemperature 1.3.6.1.4.1.6027.3.11.1.3.1.1.16 Species Temperature value of the Optics
inserted
SNMP Example Output (Single Interface)
DellEMC$ snmpwalk -v 2c -c public -m all -M 10.16.150.140 .1.3.6.1.4.1.6027.3.11.1.3 | grep
2112517
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransDeviceName.2112517 = STRING: "stack-unit-1
port-31"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransPort.2112517 = STRING: "Fo 1/49/1"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransOpticsPresent.2112517 = INTEGER: true(1)
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransOpticsType.2112517 = STRING: "40GBASE-LR4"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransVendorName.2112517 = STRING: "FINISAR CORP."
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransPartNumber.2112517 = STRING: "FTL4C1QE1C-FC"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransSerialNumber.2112517 = STRING: "UNF0FKU"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane1.2112517 = ""