Users Guide

MIB Support for 25G, 40G, 50G, 100G Optical
Transceiver or DAC cable IDPROM user info
Dell EMC Networking provides MIB objects to display the information for 25G, 40G, 50G, 100G Optical Transceiver or DAC cable IDPROM.
The following table lists the related MIB objects, OID and description for the same:
Table 100. MIB Objects to Display support for 25G, 40G, 50G, 100G Optical Transceiver or DAC cable IDPROM user info
MIB Object OID Description
dellNetIfTransceiverData 1.3.6.1.4.1.6027.3.11.1.3 Species the Transceiver Data Main
dellNetIfTransceiverDataTable 1.3.6.1.4.1.6027.3.11.1.3.1 Species the Transceiver Data Table
dellNetIfTransceiverDataEntry 1.3.6.1.4.1.6027.3.11.1.3.1.1 Species the Transceiver Data Entry Point
dellNetIfTransDeviceName 1.3.6.1.4.1.6027.3.11.1.3.1.1.1 Species the Transceiver Device name
dellNetIfTransPort 1.3.6.1.4.1.6027.3.11.1.3.1.1.2 Species the Transceiver Port Name
dellNetIfTransOpticsPresent 1.3.6.1.4.1.6027.3.11.1.3.1.1.3 Species whether Optics is present in the
Port or not
dellNetIfTransOpticsType 1.3.6.1.4.1.6027.3.11.1.3.1.1.4 Species the Optic Type inserted
dellNetIfTransVendorName 1.3.6.1.4.1.6027.3.11.1.3.1.1.5 Species the Vendor Name of the Optic
inserted
dellNetIfTransPartNumber 1.3.6.1.4.1.6027.3.11.1.3.1.1.6 Species the Part Number of the Optic
inserted
dellNetIfTransSerialNumber 1.3.6.1.4.1.6027.3.11.1.3.1.1.7 Species the Serial Number of the Optic
inserted
dellNetIfTransTransmitPowerLane1 1.3.6.1.4.1.6027.3.11.1.3.1.1.8 Species Lane 1 Tx power value in dBm
dellNetIfTransTransmitPowerLane2 1.3.6.1.4.1.6027.3.11.1.3.1.1.9 Species Lane 2 Tx power value in dBm
dellNetIfTransTransmitPowerLane3 1.3.6.1.4.1.6027.3.11.1.3.1.1.10 Species Lane 3 Tx power value in dBm
dellNetIfTransTransmitPowerLane4 1.3.6.1.4.1.6027.3.11.1.3.1.1.11 Species Lane 4 Tx power value in dBm
dellNetIfTransReceivePowerLane1 1.3.6.1.4.1.6027.3.11.1.3.1.1.12 Species Lane 1 Rx power value in dBm
dellNetIfTransReceivePowerLane2 1.3.6.1.4.1.6027.3.11.1.3.1.1.13 Species Lane 2 Rx power value in dBm
dellNetIfTransReceivePowerLane3 1.3.6.1.4.1.6027.3.11.1.3.1.1.14 Species Lane 3 Rx power value in dBm
dellNetIfTransReceivePowerLane4 1.3.6.1.4.1.6027.3.11.1.3.1.1.15 Species Lane 4 Rx power value in dBm
dellNetIfTransTemperature 1.3.6.1.4.1.6027.3.11.1.3.1.1.16 Species Temperature value of the Optics
inserted
SNMP Example Output (Single Interface)
DellEMC$ snmpwalk -v 2c -c public -m all -M 10.16.150.140 .1.3.6.1.4.1.6027.3.11.1.3 | grep
2112517
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransDeviceName.2112517 = STRING: "stack-unit-1
port-31"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransPort.2112517 = STRING: "Fo 1/49/1"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransOpticsPresent.2112517 = INTEGER: true(1)
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransOpticsType.2112517 = STRING: "40GBASE-LR4"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransVendorName.2112517 = STRING: "FINISAR CORP."
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransPartNumber.2112517 = STRING: "FTL4C1QE1C-FC"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransSerialNumber.2112517 = STRING: "UNF0FKU"
DELL-NETWORKING-IF-EXTENSION-MIB::dellNetIfTransTransmitPowerLane1.2112517 = ""
Simple Network Management Protocol (SNMP)
905