Install Guide

Parameter Specications
Storage Humidity 5 to 95 percent, non-condensing
Thermal Output
Typical: 1170.4 BTU/hr (343 W)
Maximum: 3057.3 BTU/hr (896 W)
Maximum operational altitude 10,000 feet (3,048 meters)
Maximum non-operational altitude No performance degradation to 35,000 feet (10,668 meters)
Shock SV0115 — ODM
Table 12. AC power requirements
Parameter Specications
Power Supply 100–240 VAC 50/60 Hz
Maximum Current Draw Per System 12A–6.5A @ 100–240 VAC
PSU Maximum Power Capability 1100 Watts
Typical and Maximum Power Consumption
343 Watts typical
896 Watts maximum
Reliability MTBF 1,154,397 hours
Table 13. DC power requirements
Parameter Specications
PSU Maximum Power Capability 1100 Watts
PSU Maximum current required 32A
Minimum and maximum input voltage range −40.5 V / −48 V/ −60 V
Input power at full load
−40.5 V/970 W −48 V/930 W −60 V/950 W, without fan
−40.5 V/980 W −48 V/940 W −60V/ 960 W, with fan
Input current at full load
−40.5V/23.8A −48V/19.0A −60V/ 15.6A, without fan
−40.5V/24.0A −48V/19.2A −60V/ 16.0A, with fan
Start up VDC 39.0+/−1.5 V
Start o VDC 37.5+/−1.5 V
IEEE standards
The S6100–ON complies with the following IEEE standards:
802.3ab Gigabit Ethernet (1000BASE-T)
802.3ae 10 Gigabit Ethernet (10GBASE-X)
802.3ba 40 Gigabit Ethernet (40GBase-SR4, 40GBase-CR4) on optical ports
802.3ba 100 Gigabit Ethernet
802.3bj 100 Gigabit Ethernet
Specications
47