White Papers
ip address ip-address mask
• Enable the interface.
INTERFACE mode
no shutdown
• The interface is the management interface.
INTEFACE mode
description
Example of the show interface and show ip route Commands
To display the conguration for a given port, use the show interface command in EXEC Privilege mode, as shown in the following
example. To display the routing table, use the show ip route command in EXEC Privilege mode.
DellEMC#show int TenGigabitEthernet 1/1/1/1
TenGigabitEthernet 1/1/1/1 is up, line protocol is up
Description: This is the Managment Interface
Hardware is DellEMCEth, address is 00:01:e8:cc:cc:ce
Current address is 00:01:e8:cc:cc:ce
Pluggable media not present
Interface index is 46449666
Internet address is 10.11.131.240/23
[output omitted]
DellEMC#show ip route
Codes: C - connected, S - static, R - RIP,
B - BGP, IN - internal BGP, EX - external BGP,LO - Locally Originated,
O - OSPF, IA - OSPF inter area, N1 - OSPF NSSA external type 1,
N2 - OSPF NSSA external type 2, E1 - OSPF external type 1,
E2 - OSPF external type 2, i - IS-IS, L1 - IS-IS level-1,
L2 - IS-IS level-2, IA - IS-IS inter area, * - candidate default,
> - non-active route, + - summary route
Gateway of last resort is 10.11.131.254 to network 0.0.0.0
Destination Gateway Dist/Metric Last Change
----------- ------- ----------- -----------
*S 0.0.0.0/0 via 10.11.131.254, Te 1/1/1/1 1/0 1d2h
C 10.11.130.0/23 Direct, Te 1/1/1/1 0/0 1d2h
DellEMC#
S6100 — OIR
This section deals with information on the S6100–OIR (Online Insertion and Removal) feature.
Online Insertion and Removal of Modules
There are 3 scenarios you may come across with regard to Online Insertion and Removal of Modules:
1 Inserting a module in an empty slot (a module slot that did not have any module-type provision at, and since the last reboot of the
system):
a QSFP+, and QSFP28 modules can be inserted in the empty module slot without any provisioning.
b In case of a QSFP28_4CXP module, provision QSFP28_4CXP module-type on the module slot, save the conguration and reload
the system prior to inserting the module in the empty slot.
2 Changing from one module type to another:
a Remove the previously existing module.
b Remove the previously existing module-type conguration from the module slot.
Interfaces
393