Specifications
This section lists the Z9264F-ON switch specifications.
CAUTION: Operate the product at an ambient temperature not higher than 45°C (113°F).
CAUTION: Lithium Battery Caution: There is a danger of explosion if the battery is incorrectly replaced.
Replace only with same or equivalent type of battery. Dispose of the batteries according to the manufacturer's
instructions.
NOTE: For RoHS information, see Restricted Material Compliance.
Topics:
• Chassis physical design
• IEEE standards
• Agency compliance
• USA Federal Communications Commission FCC statement
• European Union EMC directive conformance statement
• Japan VCCI compliance for class A equipment
• Korean certification of compliance
• China warning
• Safety standards and compliance agency certifications
• Electromagnetic compatibility
• Product recycling and disposal
Chassis physical design
Table 5. Chassis physical design
Parameter Specifications
Height 3.37 inches (85.6 mm)
Width 17.4 inches (442 mm)
Depth
● Chassis: 20.0 inches (510 mm)
● PSU/fan tray handle: 1.38 inches (35 mm)
Chassis weight with factory-installed components
● 34.6 lbs (2 PSUs and 4 fans)
● 15.7 kg (2 PSUs and 4 fans)
Rack clearance required
● Front: 5 inches (12.7 cm)
● Back: 5 inches (12.7 cm)
Table 6. Environmental parameters
Parameter Specifications
Operating temperature 0°C to 45°C (32°F to 113°F)
● -5°C to 45°C (23°F to 113°F) short term
● Short term is </= 1% of operational hours per year.
NOTE: Reduce maximum temperature by 1°C/125 meters
(1°F/228 feet) above 950 meters (3,117 feet).
10