Users Guide
ade service is up:software upgrade service up
--More--
View logging process names
OS10# show logging process-names
dn_alm
dn_app_vlt
dn_app_vrrp
dn_bgp
dn_dot1x
dn_eqa
dn_eqm
dn_eth_drv
dn_etl
dn_i3
dn_ifm
dn_infra_afs
dn_issu
dn_l2_services
dn_l2_services_
dn_l2_services_
dn_l2_services_
dn_l2_services_
dn_l3_core_serv
dn_l3_service
dn_lacp
dn_lldp
dn_mgmt_entity_
--More--
Environmental monitoring
Monitors the hardware environment to detect temperature, CPU, and memory utilization.
View environment
OS10# show environment
Unit    State             Temperature Voltage
--------------------------------------------
1       up                42
--------------------------------------------
Thermal sensors
Unit   Sensor-Id        Sensor-name          Temperature
---------------------------------------------------------
1       1           T2 temp sensor               28 
1       2           system-NIC temp sensor       25 
1       3           Ambient temp sensor          24 
1       4           NPU temp sensor              40
---------------------------------------------------------
Link-bundle monitoring
Monitoring link aggregation group (LAG) bundles allows the traffic distribution amounts in a link to look for unfair distribution at
any given time. A threshold of 60% is an acceptable amount of traffic on a member link.
Links are monitored in 15-second intervals for three consecutive instances. Any deviation within that time sends syslog and an
alarm event generates. When the deviation clears, another syslog sends and a clear alarm event generates.
Link-bundle utilization calculates the total bandwidth of all links divided by the total bytes-per-second of all links. If you enable
monitoring, the utilization calculation performs when the utilization of the link-bundle (not a link within a bundle) exceeds 60%.
Configure Threshold level for link-bundle monitoring
OS10(config)# link-bundle-trigger-threshold 10
Troubleshoot Dell EMC SmartFabric OS10
1809