Users Guide
Name:              EQM_MORE_PSU_FAULT
Description:       psu 2 is not working correctly
Raise-time:        Sun 10-07-2018 18:39:47
Ack-time:
State:             raised
-------------------------------------------
Supported
Releases
10.4.3E or later
show alarms severity
Displays all active alarms corresponding to a specific severity level.
Syntax
show alarms severity severity
Parameters severity — Set the alarm severity:
● critical — Critical alarm severity.
● major — Major alarm severity.
● minor — Minor alarm severity.
● warning — Warning alarm severity.
Default Not configured
Command Mode EXEC
Usage
Information
None
Example
(Warning)
OS10# show alarms severity warning
Active-alarm details - 1
-------------------------------------------
Sequence Number:   5
Severity:          warning
Type:              1081364
Source:            Node.1-Unit.1
Name:              EQM_THERMAL_WARN_CROSSED
Description:
Raise-time:        Sat 10-06-2018 0:1:5
Ack-time:          Sun 10-07-2018 20:39:47
New:               true
State:             raised
Example
(Critical)
OS10# show alarms severity critical
Active-alarm details - 0
-------------------------------------------
Sequence Number:   1
Severity:          critical
Type:              1081367
Source:            Node.1-Unit.1
Name:              EQM_THERMAL_CRIT_CROSSED
Description:
Raise-time:        Sat 10-06-2018 0:1:5
Ack-time:          Sun 10-07-2018 20:39:47
New:               true
State:             raised
Example (Minor)
NOS# show alarms severity minor
Active-alarm details - 1
-------------------------------------------
Sequence Number:   4
Severity:          minor
Type:              1081375
Troubleshoot Dell EMC SmartFabric OS10 1813