Deployment Guide
52  VCF on VxRail Multirack Deployment using BGP EVPN 
8.8  Add the NSX-T edge nodes to the transport zones 
After you deploy the NSX-T edge nodes and join them to the management plane, to connect the nodes to the 
workload domain. Next, add the nodes to the transport zones for uplink and overlay traffic and configure the 
N-VDS on each edge node. Table 16 shows the values that are used for both edge nodes.
Edge node transport zone settings 
Setting 
Value for sfo01wesg01 
Value for sfo01esg02 
Transport Zones 
sfo01-w-uplink01(VLAN) 
sfo01-w-uplink01(VLAN) 
sfo01-w-uplink02(VLAN) 
sfo01-w-uplink02(VLAN) 
sfo01-w-overlay(Overlay) 
sfo01-w-overlay(Overlay) 
Table 17 shows the Edge node N-VDS settings. 
Edge node N-VDS settings 
Setting 
Value for sfo01wesg01 
Value for sfo01esg02 
Edge Switch Name 
sfo01-w-nvds01 
sfo01-w-nvds01 
Uplink Profile 
sfo01-w-overlay-profile 
sfo01-w-overlay-profile 
IP Assignment 
Use Static IP List 
Use Static IP List 
Static IP List 
172.16.49.21 
172.16.49.22 
Gateway 
172.16.49.253 
172.16.49.253 
Subnet Mask 
255.255.255.0 
255.255.255.0 
Virtual NICs 
fp-eth0 uplink-1 
fp-eth0 uplink-1 